Skip to main content

Showing 1–19 of 19 results for author: Di Pietro, G

.
  1. arXiv:2407.07903  [pdf, ps, other

    math.GM

    Euclidean Tours in Fairy Chess

    Authors: Gabriele Di Pietro, Marco Ripà

    Abstract: The present paper aims to extend the knight's tour problem for $k$-dimensional grids of the form $\{0,1\}^k$ to other fairy chess leapers. Accordingly, we constructively show the existence of closed tours in $2 \times 2 \times \cdots \times 2$ ($k$ times) chessboards concerning the wazir, the threeleaper, and the zebra, for all $k \geq 15$. Our result considers the three above-mentioned leapers an… ▽ More

    Submitted 27 June, 2024; originally announced July 2024.

    Comments: 9 pages

    MSC Class: 05C12; 05C38 (Primary) 05C57 (Secondary)

  2. arXiv:2004.02024  [pdf, other

    physics.ins-det astro-ph.IM hep-ex

    SiPM-matrix readout of two-phase argon detectors using electroluminescence in the visible and near infrared range

    Authors: The DarkSide collaboration, C. E. Aalseth, S. Abdelhakim, P. Agnes, R. Ajaj, I. F. M. Albuquerque, T. Alexander, A. Alici, A. K. Alton, P. Amaudruz, F. Ameli, J. Anstey, P. Antonioli, M. Arba, S. Arcelli, R. Ardito, I. J. Arnquist, P. Arpaia, D. M. Asner, A. Asunskis, M. Ave, H. O. Back, V. Barbaryan, A. Barrado Olmedo, G. Batignani , et al. (290 additional authors not shown)

    Abstract: Proportional electroluminescence (EL) in noble gases is used in two-phase detectors for dark matter searches to record (in the gas phase) the ionization signal induced by particle scattering in the liquid phase. The "standard" EL mechanism is considered to be due to noble gas excimer emission in the vacuum ultraviolet (VUV). In addition, there are two alternative mechanisms, producing light in the… ▽ More

    Submitted 26 February, 2021; v1 submitted 4 April, 2020; originally announced April 2020.

    Comments: 26 pages, 22 figures, 3 tables

    Journal ref: Eur. Phys. J. C (2021) 81: 153

  3. arXiv:2001.08106  [pdf, other

    astro-ph.IM physics.ins-det

    Design and construction of a new detector to measure ultra-low radioactive-isotope contamination of argon

    Authors: The DarkSide Collaboration, C. E. Aalseth, S. Abdelhakim, F. Acerbi, P. Agnes, R. Ajaj, I. F. M. Albuquerque, T. Alexander, A. Alici, A. K. Alton, P. Amaudruz, F. Ameli, J. Anstey, P. Antonioli, M. Arba, S. Arcelli, R. Ardito, I. J. Arnquist, P. Arpaia, D. M. Asner, A. Asunskis, M. Ave, H. O. Back, A. Barrado Olmedo, G. Batignani , et al. (306 additional authors not shown)

    Abstract: Large liquid argon detectors offer one of the best avenues for the detection of galactic weakly interacting massive particles (WIMPs) via their scattering on atomic nuclei. The liquid argon target allows exquisite discrimination between nuclear and electron recoil signals via pulse-shape discrimination of the scintillation signals. Atmospheric argon (AAr), however, has a naturally occurring radioa… ▽ More

    Submitted 22 January, 2020; originally announced January 2020.

    Comments: 13 pages, 8 figures. Corresponding author: E. Sánchez García

  4. arXiv:1907.09332  [pdf, other

    astro-ph.IM physics.ins-det

    Measurement of the ion fraction and mobility of $^{218}$Po produced in $^{222}$Rn decays in liquid argon

    Authors: P. Agnes, I. F. M. Albuquerque, T. Alexander, A. K. Alton, M. Ave, H. O. Back, G. Batignani, K. Biery, V. Bocci, G. Bonfini, W. M. Bonivento, B. Bottino, S. Bussino, M. Cadeddu, M. Cadoni, F. Calaprice, A. Caminata, N. Canci, A. Candela, M. Caravati, M. Cariello, M. Carlini, M. Carpinelli, S. Catalanotti, V. Cataudella , et al. (141 additional authors not shown)

    Abstract: We report measurements of the charged daughter fraction of $^{218}$Po as a result of the $^{222}$Rn alpha decay, and the mobility of $^{218}$Po$^+$ ions, using radon-polonium coincidences from the $^{238}$U chain identified in 532 live-days of DarkSide-50 WIMP-search data. The fraction of $^{218}$Po that is charged is found to be 0.37$\pm$0.03 and the mobility of $^{218}$Po$^+$ is (8.6$\pm$0.1)… ▽ More

    Submitted 28 October, 2019; v1 submitted 22 July, 2019; originally announced July 2019.

    Journal ref: JINST 14 P11018 (2019)

  5. arXiv:1907.04761  [pdf, other

    cs.RO cs.CV cs.LG

    Towards Affordance Prediction with Vision via Task Oriented Grasp Quality Metrics

    Authors: Luca Cavalli, Gianpaolo Di Pietro, Matteo Matteucci

    Abstract: While many quality metrics exist to evaluate the quality of a grasp by itself, no clear quantification of the quality of a grasp relatively to the task the grasp is used for has been defined yet. In this paper we propose a framework to extend the concept of grasp quality metric to task-oriented gras** by defining affordance functions via basic grasp metrics for an open set of task affordances. W… ▽ More

    Submitted 10 July, 2019; originally announced July 2019.

    Comments: 8 pages, presented at the Second International Workshop on Computational Models of Affordance in Robotics

  6. arXiv:1802.07198  [pdf, other

    astro-ph.CO astro-ph.IM

    DarkSide-50 532-day Dark Matter Search with Low-Radioactivity Argon

    Authors: The DarkSide Collaboration, P. Agnes, I. F. M. Albuquerque, T. Alexander, A. K. Alton, G. R. Araujo, M. Ave, H. O. Back, B. Baldin, G. Batignani, K. Biery, V. Bocci, G. Bonfini, W. Bonivento, B. Bottino, F. Budano, S. Bussino, M. Cadeddu, M. Cadoni, F. Calaprice, A. Caminata, N. Canci, A. Candela, M. Caravati, M. Cariello , et al. (150 additional authors not shown)

    Abstract: The DarkSide-50 direct-detection dark matter experiment is a dual-phase argon time projection chamber operating at Laboratori Nazionali del Gran Sasso. This paper reports on the blind analysis of a (16,660+-270) kg d exposure using a target of low-radioactivity argon extracted from underground sources. We find no events in the dark matter selection box and set a 90% C.L. upper limit on the dark ma… ▽ More

    Submitted 19 November, 2018; v1 submitted 20 February, 2018; originally announced February 2018.

    Comments: 17 pages, 13 figures. V3 changes: updates for clarity for publication, additional figure

    Journal ref: Phys. Rev. D 98, 102006 (2018)

  7. Constraints on Sub-GeV Dark Matter-Electron Scattering from the DarkSide-50 Experiment

    Authors: The DarkSide Collaboration, P. Agnes, I. F. M. Albuquerque, T. Alexander, A. K. Alton, G. R. Araujo, D. M. Asner, M. Ave, H. O. Back, B. Baldin, G. Batignani, K. Biery, V. Bocci, G. Bonfini, W. Bonivento, B. Bottino, F. Budano, S. Bussino, M. Cadeddu, M. Cadoni, F. Calaprice, A. Caminata, N. Canci, A. Candela, M. Caravati , et al. (171 additional authors not shown)

    Abstract: We present new constraints on sub-GeV dark matter particles scattering off electrons in argon based on an analysis of ionization signal data from the DarkSide-50 detector.

    Submitted 3 October, 2018; v1 submitted 20 February, 2018; originally announced February 2018.

    Comments: replaced with published version

    Journal ref: Phys. Rev. Lett. 121, 111303 (2018)

  8. arXiv:1802.06994  [pdf, other

    astro-ph.HE astro-ph.CO

    Low-Mass Dark Matter Search with the DarkSide-50 Experiment

    Authors: The DarkSide Collaboration, P. Agnes, I. F. M. Albuquerque, T. Alexander, A. K. Alton, G. R. Araujo, D. M. Asner, M. Ave, H. O. Back, B. Baldin, G. Batignani, K. Biery, V. Bocci, G. Bonfini, W. Bonivento, B. Bottino, F. Budano, S. Bussino, M. Cadeddu, M. Cadoni, F. Calaprice, A. Caminata, N. Canci, A. Candela, M. Caravati , et al. (170 additional authors not shown)

    Abstract: We present the results of a search for dark matter WIMPs in the mass range below 20 GeV/c^2 using a target of low-radioactivity argon. The data were obtained using the DarkSide-50 apparatus at Laboratori Nazionali del Gran Sasso (LNGS). The analysis is based on the ionization signal, for which the DarkSide-50 time projection chamber is fully efficient at 0.1 keVee. The observed rate in the detecto… ▽ More

    Submitted 28 August, 2018; v1 submitted 20 February, 2018; originally announced February 2018.

    Comments: 9 pages, 8 figures; submission accepted by journal

    Journal ref: Phys. Rev. Lett. 121, 081307 (2018)

  9. Electroluminescence pulse shape and electron diffusion in liquid argon measured in a dual-phase TPC

    Authors: P. Agnes, I. F. M. Albuquerque, T. Alexander, A. K. Alton, D. M. Asner, M. P. Ave, H. O. Back, B. Baldin, G. Batignani, K. Biery, V. Bocci, G. Bonfini, W. Bonivento, M. Bossa, B. Bottino, F. Budano, S. Bussino, M. Cadeddu, M. Cadoni, F. Calaprice, A. Caminata, N. Canci, A. Candela, M. Caravati, M. Cariello , et al. (141 additional authors not shown)

    Abstract: We report the measurement of the longitudinal diffusion constant in liquid argon with the DarkSide-50 dual-phase time projection chamber. The measurement is performed at drift electric fields of 100 V/cm, 150 V/cm, and 200 V/cm using high statistics $^{39}$Ar decays from atmospheric argon. We derive an expression to describe the pulse shape of the electroluminescence signal (S2) in dual-phase TPCs… ▽ More

    Submitted 23 July, 2018; v1 submitted 5 February, 2018; originally announced February 2018.

  10. DarkSide-20k: A 20 Tonne Two-Phase LAr TPC for Direct Dark Matter Detection at LNGS

    Authors: C. E. Aalseth, F. Acerbi, P. Agnes, I. F. M. Albuquerque, T. Alexander, A. Alici, A. K. Alton, P. Antonioli, S. Arcelli, R. Ardito, I. J. Arnquist, D. M. Asner, M. Ave, H. O. Back, A. I. Barrado Olmedo, G. Batignani, E. Bertoldo, S. Bettarini, M. G. Bisogni, V. Bocci, A. Bondar, G. Bonfini, W. Bonivento, M. Bossa, B. Bottino , et al. (260 additional authors not shown)

    Abstract: Building on the successful experience in operating the DarkSide-50 detector, the DarkSide Collaboration is going to construct DarkSide-20k, a direct WIMP search detector using a two-phase Liquid Argon Time Projection Chamber (LArTPC) with an active (fiducial) mass of 23 t (20 t). The DarkSide-20k LArTPC will be deployed within a shield/veto with a spherical Liquid Scintillator Veto (LSV) inside a… ▽ More

    Submitted 25 July, 2017; originally announced July 2017.

    Report number: FERMILAB-PUB-17-298-PPD

    Journal ref: Aalseth, C.E., Acerbi, F., Agnes, P. et al. Eur. Phys. J. Plus (2018) 133: 131

  11. arXiv:1707.05630  [pdf, other

    physics.ins-det hep-ex

    Simulation of argon response and light detection in the DarkSide-50 dual phase TPC

    Authors: The DarkSide Collaboration, P. Agnes, I. F. M. Albuquerque, T. Alexander, A. K. Alton, D. M. Asner, H. O. Back, K. Biery, V. Bocci, G. Bonfini, W. Bonivento, M. Bossa, B. Bottino, F. Budano, S. Bussino, M. Cadeddu, M. Cadoni, F. Calaprice, N. Canci, A. Candela, M. Caravati, M. Cariello, M. Carlini, S. Catalanotti, V. Cataudella , et al. (125 additional authors not shown)

    Abstract: A Geant4-based Monte Carlo package named G4DS has been developed to simulate the response of DarkSide-50, an experiment operating since 2013 at LNGS, designed to detect WIMP interactions in liquid argon. In the process of WIMP searches, DarkSide-50 has achieved two fundamental milestones: the rejection of electron recoil background with a power of ~10^7, using the pulse shape discrimination techni… ▽ More

    Submitted 26 September, 2017; v1 submitted 18 July, 2017; originally announced July 2017.

    Comments: 29 pages, 23 figures, 1 table

  12. Cryogenic Characterization of FBK RGB-HD SiPMs

    Authors: C. E. Aalseth, F. Acerbi, P. Agnes, I. F. M. Albuquerque, T. Alexander, A. Alici, A. K. Alton, P. Ampudia, P. Antonioli, S. Arcelli, R. Ardito, I. J. Arnquist, D. M. Asner, H. O. Back, G. Batignani, E. Bertoldo, S. Bettarini, M. G. Bisogni, V. Bocci, A. Bondar, G. Bonfini, W. Bonivento, M. Bossa, B. Bottino, R. Bunker , et al. (246 additional authors not shown)

    Abstract: We report on the cryogenic characterization of Red Green Blue - High Density (RGB-HD) SiPMs developed at Fondazione Bruno Kessler (FBK) as part of the DarkSide program of dark matter searches with liquid argon time projection chambers. A dedicated setup was used to measure the primary dark noise, the correlated noise, and the gain of the SiPMs at varying temperatures. A custom-made data acquisitio… ▽ More

    Submitted 12 September, 2017; v1 submitted 19 May, 2017; originally announced May 2017.

  13. CALIS - a CALibration Insertion System for the DarkSide-50 dark matter search experiment

    Authors: P. Agnes, I. F. M. Albuquerque, T. Alexander, A. K. Alton, D. M. Asner, H. O. Back, B. Baldin, K. Biery, V. Bocci, G. Bonfini, W. Bonivento, M. Bossa, B. Bottino, A. Brigatti, J. Brodsky, F. Budano, S. Bussino, M. Cadeddu, L. Cadonati, M. Cadoni, F. Calaprice, N. Canci, A. Candela, M. Caravati, M. Cariello , et al. (140 additional authors not shown)

    Abstract: This paper describes the design, fabrication, commissioning and use of a CALibration source Insertion System (CALIS) in the DarkSide-50 direct dark matter search experiment. CALIS deploys radioactive sources into the liquid scintillator veto to characterize the detector response and detection efficiency of the DarkSide-50 Liquid Argon Time Projection Chamber, and the surrounding 30 t organic liqui… ▽ More

    Submitted 27 September, 2017; v1 submitted 8 November, 2016; originally announced November 2016.

    Comments: 21 pages, 11 figures

  14. arXiv:1611.00241  [pdf, other

    physics.ins-det nucl-ex

    Effect of Low Electric Fields on Alpha Scintillation Light Yield in Liquid Argon

    Authors: P. Agnes, I. F. M. Albuquerque, T. Alexander, A. K. Alton, D. M. Asner, H. O. Back, B. Baldin, K. Biery, V. Bocci, G. Bonfini, W. Bonivento, M. Bossa, B. Bottino, A. Brigatti, J. Brodsky, F. Budano, S. Bussino, M. Cadeddu, M. Cadoni, F. Calaprice, N. Canci, A. Candela, M. Caravati, M. Cariello, M. Carlini , et al. (136 additional authors not shown)

    Abstract: Measurements were made of scintillation light yield of alpha particles from the $^{222}$Rn decay chain within the DarkSide-50 liquid argon time projection chamber. The light yield was found to increase as the applied electric field increased, with alphas in a 200 V/cm electric field exhibiting a 2% increase in light yield compared to alphas in no field.

    Submitted 4 November, 2016; v1 submitted 1 November, 2016; originally announced November 2016.

    Comments: 5 pages, 5 figures

    Journal ref: P. Agnes et al 2017 JINST 12 P01021

  15. arXiv:1606.03316  [pdf, other

    physics.ins-det hep-ex

    The Electronics and Data Acquisition System for the DarkSide-50 Veto Detectors

    Authors: P. Agnes, L. Agostino, I. F. M. Albuquerque, T. Alexander, A. K. Alton, K. Arisaka, H. O. Back, B. Baldin, K. Biery, G. Bonfini, M. Bossa, B. Bottino, A. Brigatti, J. Brodsky, F. Budano, S. Bussino, M. Cadeddu, M. Cadoni, F. Calaprice, N. Canci, A. Candela, H. Cao, M. Cariello, M. Carlini, S. Catalanotti , et al. (133 additional authors not shown)

    Abstract: DarkSide-50 is a detector for dark matter candidates in the form of weakly interacting massive particles (WIMPs). It utilizes a liquid argon time projection chamber (LAr TPC) for the inner main detector. The TPC is surrounded by a liquid scintillator veto (LSV) and a water Cherenkov veto detector (WCV). The LSV and WCV, both instrumented with PMTs, act as the neutron and cosmogenic muon veto detec… ▽ More

    Submitted 10 June, 2016; originally announced June 2016.

    Journal ref: Journal of Instrumentation, 11 (2016): P12007

  16. arXiv:1512.07896  [pdf, other

    physics.ins-det hep-ex

    The veto system of the DarkSide-50 experiment

    Authors: The DarkSide Collaboration, P. Agnes, L. Agostino, I. F. M. Albuquerque, T. Alexander, A. K. Alton, K. Arisaka, H. O. Back, B. Baldin, K. Biery, G. Bonfini, M. Bossa, B. Bottino, A. Brigatti, J. Brodsky, F. Budano, S. Bussino, M. Cadeddu, L. Cadonati, M. Cadoni, F. Calaprice, N. Canci, A. Candela, H. Cao, M. Cariello , et al. (136 additional authors not shown)

    Abstract: Nuclear recoil events produced by neutron scatters form one of the most important classes of background in WIMP direct detection experiments, as they may produce nuclear recoils that look exactly like WIMP interactions. In DarkSide-50, we both actively suppress and measure the rate of neutron-induced background events using our neutron veto, composed of a boron-loaded liquid scintillator detector… ▽ More

    Submitted 24 December, 2015; originally announced December 2015.

    Journal ref: Journal of Instrumentation, 11 (2016): P03016

  17. arXiv:1510.00702  [pdf, other

    astro-ph.CO astro-ph.IM hep-ex physics.ins-det

    Results from the first use of low radioactivity argon in a dark matter search

    Authors: The DarkSide Collaboration, P. Agnes, L. Agostino, I. F. M. Albuquerque, T. Alexander, A. K. Alton, K. Arisaka, H. O. Back, B. Baldin, K. Biery, G. Bonfini, M. Bossa, B. Bottino, A. Brigatti, J. Brodsky, F. Budano, S. Bussino, M. Cadeddu, L. Cadonati, M. Cadoni, F. Calaprice, N. Canci, A. Candela, H. Cao, M. Cariello , et al. (136 additional authors not shown)

    Abstract: Liquid argon is a bright scintillator with potent particle identification properties, making it an attractive target for direct-detection dark matter searches. The DarkSide-50 dark matter search here reports the first WIMP search results obtained using a target of low-radioactivity argon. DarkSide-50 is a dark matter detector, using two-phase liquid argon time projection chamber, located at the La… ▽ More

    Submitted 13 April, 2016; v1 submitted 2 October, 2015; originally announced October 2015.

    Comments: Accepted by Phys. Rev. D

    Journal ref: Phys. Rev. D 93, 081101 (2016)

  18. arXiv:1410.0653  [pdf, other

    astro-ph.CO astro-ph.IM hep-ex physics.ins-det

    First Results from the DarkSide-50 Dark Matter Experiment at Laboratori Nazionali del Gran Sasso

    Authors: P. Agnes, T. Alexander, A. Alton, K. Arisaka, H. O. Back, B. Baldin, K. Biery, G. Bonfini, M. Bossa, A. Brigatti, J. Brodsky, F. Budano, L. Cadonati, F. Calaprice, N. Canci, A. Candela, H. Cao, M. Cariello, P. Cavalcante, A. Chavarria, A. Chepurnov, A. G. Cocco, L. Crippa, D. D'Angelo, M. D'Incecco , et al. (121 additional authors not shown)

    Abstract: We report the first results of DarkSide-50, a direct search for dark matter operating in the underground Laboratori Nazionali del Gran Sasso (LNGS) and searching for the rare nuclear recoils possibly induced by weakly interacting massive particles (WIMPs). The dark matter detector is a Liquid Argon Time Projection Chamber with a (46.4+-0.7) kg active mass, operated inside a 30 t organic liquid sci… ▽ More

    Submitted 27 February, 2015; v1 submitted 2 October, 2014; originally announced October 2014.

    Comments: 26 pages, 7 figures; updated figures and references, notably Fig. 7 has updated CDMSII curve; fixed typos; clarified some language and figures; updated references

    Journal ref: Physics Letters B 743, 456 (2015)

  19. Light Yield in DarkSide-10: a Prototype Two-phase Liquid Argon TPC for Dark Matter Searches

    Authors: T. Alexander, D. Alton, K. Arisaka, H. O. Back, P. Beltrame, J. Benziger, G. Bonfini, A. Brigatti, J. Brodsky, L. Cadonati, F. Calaprice, A. Candela, H. Cao, P. Cavalcante, A. Chavarria, A. Chepurnov, D. Cline, A. G. Cocco, C. Condon, D. D'Angelo, S. Davini, E. De Haas, A. Derbin, G. Di Pietro, I. Dratchnev , et al. (97 additional authors not shown)

    Abstract: As part of the DarkSide program of direct dark matter searches using liquid argon TPCs, a prototype detector with an active volume containing 10 kg of liquid argon, DarkSide-10, was built and operated underground in the Gran Sasso National Laboratory in Italy. A critically important parameter for such devices is the scintillation light yield, as photon statistics limits the rejection of electron-r… ▽ More

    Submitted 14 August, 2013; v1 submitted 27 April, 2012; originally announced April 2012.

    Comments: 10 pages, 7 figures, Accepted for publication in Astroparticle Physics