-
The AWAKE Run 2 programme and beyond
Authors:
Edda Gschwendtner,
Konstantin Lotov,
Patric Muggli,
Matthew Wing,
Riccardo Agnello,
Claudia Christina Ahdida,
Maria Carolina Amoedo Goncalves,
Yanis Andrebe,
Oznur Apsimon,
Robert Apsimon,
Jordan Matias Arnesano,
Anna-Maria Bachmann,
Diego Barrientos,
Fabian Batsch,
Vittorio Bencini,
Michele Bergamaschi,
Patrick Blanchard,
Philip Nicholas Burrows,
Birger Buttenschön,
Allen Caldwell,
James Chappell,
Eric Chevallay,
Moses Chung,
David Andrew Cooke,
Heiko Damerau
, et al. (77 additional authors not shown)
Abstract:
Plasma wakefield acceleration is a promising technology to reduce the size of particle accelerators. Use of high energy protons to drive wakefields in plasma has been demonstrated during Run 1 of the AWAKE programme at CERN. Protons of energy 400 GeV drove wakefields that accelerated electrons to 2 GeV in under 10 m of plasma. The AWAKE collaboration is now embarking on Run 2 with the main aims to…
▽ More
Plasma wakefield acceleration is a promising technology to reduce the size of particle accelerators. Use of high energy protons to drive wakefields in plasma has been demonstrated during Run 1 of the AWAKE programme at CERN. Protons of energy 400 GeV drove wakefields that accelerated electrons to 2 GeV in under 10 m of plasma. The AWAKE collaboration is now embarking on Run 2 with the main aims to demonstrate stable accelerating gradients of 0.5-1 GV/m, preserve emittance of the electron bunches during acceleration and develop plasma sources scalable to 100s of metres and beyond. By the end of Run 2, the AWAKE scheme should be able to provide electron beams for particle physics experiments and several possible experiments have already been evaluated. This article summarises the programme of AWAKE Run 2 and how it will be achieved as well as the possible application of the AWAKE scheme to novel particle physics experiments.
△ Less
Submitted 13 June, 2022;
originally announced June 2022.
-
Failure Mode and Effects Analysis (FMEA) for Experimental Use of FLASH on a Clinical Accelerator
Authors:
Mahbubur Rahman,
Rongxiao Zhang,
David J. Gladstone,
Benjamin B. Williams,
Erli Chen,
Chad A. Dexter,
Lawrence Thompson,
Petr Bruza,
Brian W. Pogue
Abstract:
Background: Use of a linear accelerator in ultra-high dose rate (UHDR) mode can provide a conduit for wider access to UHDR FLASH effects, sparing normal tissue, but care needs to be taken in the use of such systems to ensure errors are minimized.
Purpose: Failure Modes and Effects Analysis (FMEA) was carried out in a team that has been involved in converting a LINAC between clinical use and UHDR…
▽ More
Background: Use of a linear accelerator in ultra-high dose rate (UHDR) mode can provide a conduit for wider access to UHDR FLASH effects, sparing normal tissue, but care needs to be taken in the use of such systems to ensure errors are minimized.
Purpose: Failure Modes and Effects Analysis (FMEA) was carried out in a team that has been involved in converting a LINAC between clinical use and UHDR experimental mode for more than one year, following the proposed methods of TG100.
Methods: A team of 9 professionals with extensive experience were polled to outline the process map and workflow for analysis, and developed fault trees for potential errors, as well as failure modes that would results. The team scored the categories of severity magnitude (S), occurrence likelihood (O), and detectability potential (D) in a scale of 1 to 10, so that a risk priority number (RPN=S*O*D) could be assessed for each.
Results: A total of 46 potential failure modes were identified, including 5 with RPN>100. These failure modes involved 1) patient set up, 2) gating mechanisms in delivery, and 3) detector in the beam stop mechanism. Identified methods to mitigate errors included 1) use of a checklist post conversion, 2) use of robust radiation detectors, 3) automation of QA and beam consistency checks, and 4) implementation of surface guidance during beam delivery.
Conclusions: The FMEA process was considered critically important in this setting of a new use of a LINAC, and the expert team developed a higher level of confidence in the ability to safely move UHDR LINAC use towards expanded research access.
△ Less
Submitted 20 December, 2021;
originally announced December 2021.
-
Analysis of Proton Bunch Parameters in the AWAKE Experiment
Authors:
V. Hafych,
A. Caldwell,
R. Agnello,
C. C. Ahdida,
M. Aladi,
M. C. Amoedo Goncalves,
Y. Andrebe,
O. Apsimon,
R. Apsimon,
A. -M. Bachmann,
M. A. Baistrukov,
F. Batsch,
M. Bergamaschi,
P. Blanchard,
P. N. Burrows,
B. Buttenschön,
J. Chappell,
E. Chevallay,
M. Chung,
D. A. Cooke,
H. Damerau,
C. Davut,
G. Demeter,
A. Dexter,
S. Doebert
, et al. (63 additional authors not shown)
Abstract:
A precise characterization of the incoming proton bunch parameters is required to accurately simulate the self-modulation process in the Advanced Wakefield Experiment (AWAKE). This paper presents an analysis of the parameters of the incoming proton bunches used in the later stages of the AWAKE Run 1 data-taking period. The transverse structure of the bunch is observed at multiple positions along t…
▽ More
A precise characterization of the incoming proton bunch parameters is required to accurately simulate the self-modulation process in the Advanced Wakefield Experiment (AWAKE). This paper presents an analysis of the parameters of the incoming proton bunches used in the later stages of the AWAKE Run 1 data-taking period. The transverse structure of the bunch is observed at multiple positions along the beamline using scintillating or optical transition radiation screens. The parameters of a model that describes the bunch transverse dimensions and divergence are fitted to represent the observed data using Bayesian inference. The analysis is tested on simulated data and then applied to the experimental data.
△ Less
Submitted 27 September, 2021;
originally announced September 2021.
-
Simulation and Experimental Study of Proton Bunch Self-Modulation in Plasma with Linear Density Gradients
Authors:
P. I. Morales Guzmán,
P. Muggli,
R. Agnello,
C. C. Ahdida,
M. Aladi,
M. C. Amoedo Goncalves,
Y. Andrebe,
O. Apsimon,
R. Apsimon,
A. -M. Bachmann,
M. A. Baistrukov,
F. Batsch,
M. Bergamaschi,
P. Blanchard,
F. Braunmüller,
P. N. Burrows,
B. Buttenschön,
A. Caldwell,
J. Chappell,
E. Chevallay,
M. Chung,
D. A. Cooke,
H. Damerau,
C. Davut,
G. Demeter
, et al. (66 additional authors not shown)
Abstract:
We present numerical simulations and experimental results of the self-modulation of a long proton bunch in a plasma with linear density gradients along the beam path. Simulation results agree with the experimental results reported in arXiv:2007.14894v2: with negative gradients, the charge of the modulated bunch is lower than with positive gradients. In addition, the bunch modulation frequency vari…
▽ More
We present numerical simulations and experimental results of the self-modulation of a long proton bunch in a plasma with linear density gradients along the beam path. Simulation results agree with the experimental results reported in arXiv:2007.14894v2: with negative gradients, the charge of the modulated bunch is lower than with positive gradients. In addition, the bunch modulation frequency varies with gradient. Simulation results show that dephasing of the wakefields with respect to the relativistic protons along the plasma is the main cause for the loss of charge. The study of the modulation frequency reveals details about the evolution of the self-modulation process along the plasma. In particular for negative gradients, the modulation frequency across time-resolved images of the bunch indicates the position along the plasma where protons leave the wakefields. Simulations and experimental results are in excellent agreement.
△ Less
Submitted 23 July, 2021;
originally announced July 2021.
-
Experimental study of extended timescale dynamics of a plasma wakefield driven by a self-modulated proton bunch
Authors:
J. Chappell,
E. Adli,
R. Agnello,
M. Aladi,
Y. Andrebe,
O. Apsimon,
R. Apsimon,
A. -M. Bachmann,
M. A. Baistrukov,
F. Batsch,
M. Bergamaschi,
P. Blanchard,
P. N. Burrows,
B. Buttenschön,
A. Caldwell,
E. Chevallay,
M. Chung,
D. A. Cooke,
H. Damerau,
C. Davut,
G. Demeter,
L. H. Deubner,
A. Dexter,
G. P. Djotyan,
S. Doebert
, et al. (74 additional authors not shown)
Abstract:
Plasma wakefield dynamics over timescales up to 800 ps, approximately 100 plasma periods, are studied experimentally at the Advanced Wakefield Experiment (AWAKE). The development of the longitudinal wakefield amplitude driven by a self-modulated proton bunch is measured using the external injection of witness electrons that sample the fields. In simulation, resonant excitation of the wakefield cau…
▽ More
Plasma wakefield dynamics over timescales up to 800 ps, approximately 100 plasma periods, are studied experimentally at the Advanced Wakefield Experiment (AWAKE). The development of the longitudinal wakefield amplitude driven by a self-modulated proton bunch is measured using the external injection of witness electrons that sample the fields. In simulation, resonant excitation of the wakefield causes plasma electron trajectory crossing, resulting in the development of a potential outside the plasma boundary as electrons are transversely ejected. Trends consistent with the presence of this potential are experimentally measured and their dependence on wakefield amplitude are studied via seed laser timing scans and electron injection delay scans.
△ Less
Submitted 12 October, 2020;
originally announced October 2020.
-
Proton beam defocusing in AWAKE: comparison of simulations and measurements
Authors:
A. A. Gorn,
M. Turner,
E. Adli,
R. Agnello,
M. Aladi,
Y. Andrebe,
O. Apsimon,
R. Apsimon,
A. -M. Bachmann,
M. A. Baistrukov,
F. Batsch,
M. Bergamaschi,
P. Blanchard,
P. N. Burrows,
B. Buttenschon,
A. Caldwell,
J. Chappell,
E. Chevallay,
M. Chung,
D. A. Cooke,
H. Damerau,
C. Davut,
G. Demeter,
L. H. Deubner,
A. Dexter
, et al. (74 additional authors not shown)
Abstract:
In 2017, AWAKE demonstrated the seeded self-modulation (SSM) of a 400 GeV proton beam from the Super Proton Synchrotron (SPS) at CERN. The angular distribution of the protons deflected due to SSM is a quantitative measure of the process, which agrees with simulations by the two-dimensional (axisymmetric) particle-in-cell code LCODE. Agreement is achieved for beam populations between $10^{11}$ and…
▽ More
In 2017, AWAKE demonstrated the seeded self-modulation (SSM) of a 400 GeV proton beam from the Super Proton Synchrotron (SPS) at CERN. The angular distribution of the protons deflected due to SSM is a quantitative measure of the process, which agrees with simulations by the two-dimensional (axisymmetric) particle-in-cell code LCODE. Agreement is achieved for beam populations between $10^{11}$ and $3 \times 10^{11}$ particles, various plasma density gradients ($-20 ÷20\%$) and two plasma densities ($2\times 10^{14} \text{cm}^{-3}$ and $7 \times 10^{14} \text{cm}^{-3}$). The agreement is reached only in the case of a wide enough simulation box (at least five plasma wavelengths).
△ Less
Submitted 26 August, 2020;
originally announced August 2020.
-
Electron FLASH Delivery at Treatment Room Isocenter for Efficient Reversible Conversion of a Clinical LINAC
Authors:
Mahbubur Rahman,
M. Ramish Ashraf,
Rongxiao Zhang,
Petr Bruza,
Chad A. Dexter,
Lawrence Thompson,
Xu Cao,
Benjamin B. Williams,
P. Jack Hoopes,
Brian W. Pogue,
David J. Gladstone
Abstract:
Purpose: In this study, procedures were developed to achieve efficient reversible conversion of a clinical linear accelerator (LINAC) and deliver electron FLASH (eFLASH) or conventional beams to the treatment room isocenter. Material & Methods: The LINAC was converted to deliver eFLASH beam within 20 minutes by retracting the x-ray target from the beam's path, positioning the carousel on an empty…
▽ More
Purpose: In this study, procedures were developed to achieve efficient reversible conversion of a clinical linear accelerator (LINAC) and deliver electron FLASH (eFLASH) or conventional beams to the treatment room isocenter. Material & Methods: The LINAC was converted to deliver eFLASH beam within 20 minutes by retracting the x-ray target from the beam's path, positioning the carousel on an empty port, and selecting 10 MV photon beam energy in the treatment console. Dose per pulse and average dose rate were measured in a solid water phantom at different depths with Gafchromic film and OSLD. A pulse controller counted the pulses via scattered radiation signal and gated the delivery for preset pulse count. A fast photomultiplier tube-based Cherenkov detector measured per pulse beam output at 2 ns sampling rate. After conversion back to clinical mode, conventional beam output, flatness, symmetry, field size and energy were measured for all clinically commissioned energies. Results: Dose per pulse of 0.86 +/- 0.01 Gy (310 +/- 7 Gy/s average dose rate) were achieved at isocenter. The dose from simultaneous irradiation of film and OSLD were within 1%. The PMT showed the LINAC required about 5 pulses before the output stabilized and its long-term stability was within 3% for measurements performed at 3 minutes intervals. The dose, flatness, symmetry, and photon energy were unchanged from baseline and within tolerance (1%, 3%, 2%, and 0.1% respectively) after reverting to conventional beams. Conclusion: 10 MeV FLASH beams were achieved at the isocenter of the treatment room. The beam output was reproducible but requires further investigation of the ramp up time in the first 5 pulses, equivalent to <100 cGy. The eFLASH beam can irradiate both small and large subjects in minimally modified clinical settings and dose rates can be further increased by reducing the source to surface distance.
△ Less
Submitted 1 February, 2021; v1 submitted 16 August, 2020;
originally announced August 2020.
-
The Compact Linear Collider (CLIC) - 2018 Summary Report
Authors:
The CLIC,
CLICdp collaborations,
:,
T. K. Charles,
P. J. Giansiracusa,
T. G. Lucas,
R. P. Rassool,
M. Volpi,
C. Balazs,
K. Afanaciev,
V. Makarenko,
A. Patapenka,
I. Zhuk,
C. Collette,
M. J. Boland,
A. C. Abusleme Hoffman,
M. A. Diaz,
F. Garay,
Y. Chi,
X. He,
G. Pei,
S. Pei,
G. Shu,
X. Wang,
J. Zhang
, et al. (671 additional authors not shown)
Abstract:
The Compact Linear Collider (CLIC) is a TeV-scale high-luminosity linear $e^+e^-$ collider under development at CERN. Following the CLIC conceptual design published in 2012, this report provides an overview of the CLIC project, its current status, and future developments. It presents the CLIC physics potential and reports on design, technology, and implementation aspects of the accelerator and the…
▽ More
The Compact Linear Collider (CLIC) is a TeV-scale high-luminosity linear $e^+e^-$ collider under development at CERN. Following the CLIC conceptual design published in 2012, this report provides an overview of the CLIC project, its current status, and future developments. It presents the CLIC physics potential and reports on design, technology, and implementation aspects of the accelerator and the detector. CLIC is foreseen to be built and operated in stages, at centre-of-mass energies of 380 GeV, 1.5 TeV and 3 TeV, respectively. CLIC uses a two-beam acceleration scheme, in which 12 GHz accelerating structures are powered via a high-current drive beam. For the first stage, an alternative with X-band klystron powering is also considered. CLIC accelerator optimisation, technical developments and system tests have resulted in an increased energy efficiency (power around 170 MW) for the 380 GeV stage, together with a reduced cost estimate at the level of 6 billion CHF. The detector concept has been refined using improved software tools. Significant progress has been made on detector technology developments for the tracking and calorimetry systems. A wide range of CLIC physics studies has been conducted, both through full detector simulations and parametric studies, together providing a broad overview of the CLIC physics potential. Each of the three energy stages adds cornerstones of the full CLIC physics programme, such as Higgs width and couplings, top-quark properties, Higgs self-coupling, direct searches, and many precision electroweak measurements. The interpretation of the combined results gives crucial and accurate insight into new physics, largely complementary to LHC and HL-LHC. The construction of the first CLIC energy stage could start by 2026. First beams would be available by 2035, marking the beginning of a broad CLIC physics programme spanning 25-30 years.
△ Less
Submitted 6 May, 2019; v1 submitted 14 December, 2018;
originally announced December 2018.
-
Prediction of Beam Losses during Crab Cavity Quenches at the HL-LHC
Authors:
Robert Apsimon,
Graeme Burt,
Amos Dexter,
Nick Shipman,
Philippe Baudrenghien,
Rama Calaga,
Alejandro Castilla,
Alick Macpherson,
Kyrre Ness Sjobak,
Andrea Santamaria Garcia,
Niall Stapley,
Androula Alekou,
Robert Appleby
Abstract:
Studies of the crab cavities at KEKB revealed that the RF phase could shift by up to 50o within ~50 us during a quench; while the cavity voltage is still at approximately 75% of its nominal amplitude. If such a failure were to occur on the HL-LHC crab cavities, it is likely that the machine would sustain substantial damage to the beam line and surrounding infrastructure due to uncontrolled beam lo…
▽ More
Studies of the crab cavities at KEKB revealed that the RF phase could shift by up to 50o within ~50 us during a quench; while the cavity voltage is still at approximately 75% of its nominal amplitude. If such a failure were to occur on the HL-LHC crab cavities, it is likely that the machine would sustain substantial damage to the beam line and surrounding infrastructure due to uncontrolled beam loss before the machine protection system could dump the beam. We have developed a low-level RF system model, including detuning mechanisms and beam loading, and use this to simulate the behaviour of a crab cavity during a quench, modeling the low-level RF system, detuning mechanisms and beam loading. We supplement this with measurement data of the actual RF response of the proof of principle Double-Quarter Wave Crab Cravity during a quench. Extrapolating these measurements to the HL-LHC, we show that Lorentz Force detuning is the dominant effect leading to phase shifts in the crab cavity during quenches; rather than pressure detuning which is expected to be dominant for the KEKB crab cavities. The total frequency shift for the HL-LHC crab cavities during quenches is expected to be about 460 Hz, leading to a phase shift of no more than 3o. The results of the quench model are read into a particle tracking simulation, SixTrack, and used to determine the effect of quenches on the HL-LHC beam. The quench model has been benchmarked against the KEKB experimental measurements. In this paper we present the results of the simulations on a crab cavity failure for HL-LHC as well as for the SPS and show that beam loss is negligible when using a realistic low-level RF response.
△ Less
Submitted 4 December, 2018;
originally announced December 2018.
-
Experimental observation of proton bunch modulation in a plasma, at varying plasma densities
Authors:
E. Adli,
A. Ahuja,
O. Apsimon,
R. Apsimon,
A. -M. Bachmann,
D. Barrientos,
M. M. Barros,
J. Batkiewicz,
F. Batsch,
J. Bauche,
V. K. Berglyd Olsen,
M. Bernardini,
B. Biskup,
A. Boccardi,
T. Bogey,
T. Bohl,
C. Bracco,
F. Braunmüller,
S. Burger,
G. Burt,
S. Bustamante,
B. Buttenschön,
A. Caldwell,
M. Cascella,
J. Chappell
, et al. (87 additional authors not shown)
Abstract:
We give direct experimental evidence for the observation of the full transverse self-modulation of a relativistic proton bunch propagating through a dense plasma. The bunch exits the plasma with a density modulation resulting from radial wakefield effects with a period reciprocal to the plasma frequency. We show that the modulation is seeded by using an intense laser pulse co-propagating with the…
▽ More
We give direct experimental evidence for the observation of the full transverse self-modulation of a relativistic proton bunch propagating through a dense plasma. The bunch exits the plasma with a density modulation resulting from radial wakefield effects with a period reciprocal to the plasma frequency. We show that the modulation is seeded by using an intense laser pulse co-propagating with the proton bunch which creates a relativistic ionization front within the bunch. We show by varying the plasma density over one order of magnitude that the modulation period scales with the expected dependence on the plasma density.
△ Less
Submitted 1 April, 2019; v1 submitted 12 September, 2018;
originally announced September 2018.
-
Acceleration of electrons in the plasma wakefield of a proton bunch
Authors:
The AWAKE Collaboration,
E. Adli,
A. Ahuja,
O. Apsimon,
R. Apsimon,
A. -M. Bachmann,
D. Barrientos,
F. Batsch,
J. Bauche,
V. K. Berglyd Olsen,
M. Bernardini,
T. Bohl,
C. Bracco,
F. Braunmueller,
G. Burt,
B. Buttenschoen,
A. Caldwell,
M. Cascella,
J. Chappell,
E. Chevallay,
M. Chung,
D. Cooke,
H. Damerau,
L. Deacon,
L. H. Deubner
, et al. (69 additional authors not shown)
Abstract:
High energy particle accelerators have been crucial in providing a deeper understanding of fundamental particles and the forces that govern their interactions. In order to increase the energy or reduce the size of the accelerator, new acceleration schemes need to be developed. Plasma wakefield acceleration, in which the electrons in a plasma are excited, leading to strong electric fields, is one s…
▽ More
High energy particle accelerators have been crucial in providing a deeper understanding of fundamental particles and the forces that govern their interactions. In order to increase the energy or reduce the size of the accelerator, new acceleration schemes need to be developed. Plasma wakefield acceleration, in which the electrons in a plasma are excited, leading to strong electric fields, is one such promising novel acceleration technique. Pioneering experiments have shown that an intense laser pulse or electron bunch traversing a plasma, drives electric fields of 10s GV/m and above. These values are well beyond those achieved in conventional RF accelerators which are limited to ~0.1 GV/m. A limitation of laser pulses and electron bunches is their low stored energy, which motivates the use of multiple stages to reach very high energies. The use of proton bunches is compelling, as they have the potential to drive wakefields and accelerate electrons to high energy in a single accelerating stage. The long proton bunches currently available can be used, as they undergo self-modulation, a particle-plasma interaction which longitudinally splits the bunch into a series of high density microbunches, which then act resonantly to create large wakefields. The AWAKE experiment at CERN uses intense bunches of protons, each of energy 400 GeV, with a total bunch energy of 19 kJ, to drive a wakefield in a 10 m long plasma. Bunches of electrons are injected into the wakefield formed by the proton microbunches. This paper presents measurements of electrons accelerated up to 2 GeV at AWAKE. This constitutes the first demonstration of proton-driven plasma wakefield acceleration. The potential for this scheme to produce very high energy electron bunches in a single accelerating stage means that the results shown here are a significant step towards the development of future high energy particle accelerators.
△ Less
Submitted 11 October, 2018; v1 submitted 29 August, 2018;
originally announced August 2018.
-
AWAKE readiness for the study of the seeded self-modulation of a 400\,GeV proton bunch
Authors:
P. Muggli,
E. Adli,
R. Apsimon,
F. Asmus,
R. Baartman,
A. -M. Bachmann,
M. Barros Marin,
F. Batsch,
J. Bauche,
V. K. Berglyd Olsen,
M. Bernardini,
B. Biskup,
A. Boccardi,
T. Bogey,
T. Bohl,
C. Bracco,
F. Braunmuller,
S. Burger,
G. Burt,
S. Bustamante,
B. Buttenschon,
A. Butterworth,
A. Caldwell,
M. Cascella,
E. Chevallay
, et al. (82 additional authors not shown)
Abstract:
AWAKE is a proton-driven plasma wakefield acceleration experiment. % We show that the experimental setup briefly described here is ready for systematic study of the seeded self-modulation of the 400\,GeV proton bunch in the 10\,m-long rubidium plasma with density adjustable from 1 to 10$\times10^{14}$\,cm$^{-3}$. % We show that the short laser pulse used for ionization of the rubidium vapor propag…
▽ More
AWAKE is a proton-driven plasma wakefield acceleration experiment. % We show that the experimental setup briefly described here is ready for systematic study of the seeded self-modulation of the 400\,GeV proton bunch in the 10\,m-long rubidium plasma with density adjustable from 1 to 10$\times10^{14}$\,cm$^{-3}$. % We show that the short laser pulse used for ionization of the rubidium vapor propagates all the way along the column, suggesting full ionization of the vapor. % We show that ionization occurs along the proton bunch, at the laser time and that the plasma that follows affects the proton bunch. %
△ Less
Submitted 3 August, 2017;
originally announced August 2017.
-
Updated baseline for a staged Compact Linear Collider
Authors:
The CLIC,
CLICdp collaborations,
:,
M. J. Boland,
U. Felzmann,
P. J. Giansiracusa,
T. G. Lucas,
R. P. Rassool,
C. Balazs,
T. K. Charles,
K. Afanaciev,
I. Emeliantchik,
A. Ignatenko,
V. Makarenko,
N. Shumeiko,
A. Patapenka,
I. Zhuk,
A. C. Abusleme Hoffman,
M. A. Diaz Gutierrez,
M. Vogel Gonzalez,
Y. Chi,
X. He,
G. Pei,
S. Pei,
G. Shu
, et al. (493 additional authors not shown)
Abstract:
The Compact Linear Collider (CLIC) is a multi-TeV high-luminosity linear e+e- collider under development. For an optimal exploitation of its physics potential, CLIC is foreseen to be built and operated in a staged approach with three centre-of-mass energy stages ranging from a few hundred GeV up to 3 TeV. The first stage will focus on precision Standard Model physics, in particular Higgs and top-q…
▽ More
The Compact Linear Collider (CLIC) is a multi-TeV high-luminosity linear e+e- collider under development. For an optimal exploitation of its physics potential, CLIC is foreseen to be built and operated in a staged approach with three centre-of-mass energy stages ranging from a few hundred GeV up to 3 TeV. The first stage will focus on precision Standard Model physics, in particular Higgs and top-quark measurements. Subsequent stages will focus on measurements of rare Higgs processes, as well as searches for new physics processes and precision measurements of new states, e.g. states previously discovered at LHC or at CLIC itself. In the 2012 CLIC Conceptual Design Report, a fully optimised 3 TeV collider was presented, while the proposed lower energy stages were not studied to the same level of detail. This report presents an updated baseline staging scenario for CLIC. The scenario is the result of a comprehensive study addressing the performance, cost and power of the CLIC accelerator complex as a function of centre-of-mass energy and it targets optimal physics output based on the current physics landscape. The optimised staging scenario foresees three main centre-of-mass energy stages at 380 GeV, 1.5 TeV and 3 TeV for a full CLIC programme spanning 22 years. For the first stage, an alternative to the CLIC drive beam scheme is presented in which the main linac power is produced using X-band klystrons.
△ Less
Submitted 27 March, 2017; v1 submitted 26 August, 2016;
originally announced August 2016.
-
Preliminary Results of the CASCADE Hidden Sector Photon Search
Authors:
Nathan Woollett,
Ian Bailey,
Graeme Burt,
Swapan Chattopadhyay,
John Dainton,
Amos Dexter,
Phillipe Goudket,
Michael Jenkins,
Matti Kalliokoski,
Andrew Moss,
Shrikant Pattalwar,
Trina Thakker,
Peter Williams
Abstract:
Light shining through a wall experiments can be used to make measurements of photon-WISP couplings. The first stage of the CASCADE experiment at the Cockcroft Institute of Accelerator Science and Technology is intended to be a proof-of-principle experiment utilising standard microwave technologies to make a modular, cryogenic HSP detector to take advantage of future high-power superconducting cavi…
▽ More
Light shining through a wall experiments can be used to make measurements of photon-WISP couplings. The first stage of the CASCADE experiment at the Cockcroft Institute of Accelerator Science and Technology is intended to be a proof-of-principle experiment utilising standard microwave technologies to make a modular, cryogenic HSP detector to take advantage of future high-power superconducting cavity tests. In these proceedings we will be presenting the preliminary results of the CASCADE LSW experiment showing a peak expected exclusion of $1.10 \times 10^{-8}$ in the mass range from 1.96$μ$eV to 5.38$μ$eV, exceeding current limits.
△ Less
Submitted 25 September, 2015;
originally announced September 2015.
-
The EUROnu Project
Authors:
T. R. Edgecock,
O. Caretta,
T. Davenne,
C. Densham,
M. Fitton,
D. Kelliher,
P. Loveridge,
S. Machida,
C. Prior,
C. Rogers,
M. Rooney,
J. Thomason,
D. Wilcox,
E. Wildner,
I. Efthymiopoulos,
R. Garoby,
S. Gilardoni,
C. Hansen,
E. Benedetto,
E. Jensen,
A. Kosmicki,
M. Martini,
J. Osborne,
G. Prior,
T. Stora
, et al. (146 additional authors not shown)
Abstract:
The EUROnu project has studied three possible options for future, high intensity neutrino oscillation facilities in Europe. The first is a Super Beam, in which the neutrinos come from the decay of pions created by bombarding targets with a 4 MW proton beam from the CERN High Power Superconducting Proton Linac. The far detector for this facility is the 500 kt MEMPHYS water Cherenkov, located in the…
▽ More
The EUROnu project has studied three possible options for future, high intensity neutrino oscillation facilities in Europe. The first is a Super Beam, in which the neutrinos come from the decay of pions created by bombarding targets with a 4 MW proton beam from the CERN High Power Superconducting Proton Linac. The far detector for this facility is the 500 kt MEMPHYS water Cherenkov, located in the Fréjus tunnel. The second facility is the Neutrino Factory, in which the neutrinos come from the decay of μ+ and μ- beams in a storage ring. The far detector in this case is a 100 kt Magnetised Iron Neutrino Detector at a baseline of 2000 km. The third option is a Beta Beam, in which the neutrinos come from the decay of beta emitting isotopes, in particular 6He and 18Ne, also stored in a ring. The far detector is also the MEMPHYS detector in the Fréjus tunnel. EUROnu has undertaken conceptual designs of these facilities and studied the performance of the detectors. Based on this, it has determined the physics reach of each facility, in particular for the measurement of CP violation in the lepton sector, and estimated the cost of construction. These have demonstrated that the best facility to build is the Neutrino Factory. However, if a powerful proton driver is constructed for another purpose or if the MEMPHYS detector is built for astroparticle physics, the Super Beam also becomes very attractive.
△ Less
Submitted 17 May, 2013;
originally announced May 2013.
-
Wakefield dam** for the CLIC crab cavity
Authors:
P. K. Ambattu,
G. Burt,
A. C. Dexter,
R. G. Carter,
V. Khan,
R. M. Jones,
V. Dolgashev
Abstract:
A crab cavity is required in the CLIC to allow effective head-on collision of bunches at the IP. A high operating frequency is preferred as the deflection voltage required for a given rotation angle and the RF phase tolerance for a crab cavity are inversely proportional to the operating frequency. The short bunch spacing of the CLIC scheme and the high sensitivity of the crab cavity to dipole ki…
▽ More
A crab cavity is required in the CLIC to allow effective head-on collision of bunches at the IP. A high operating frequency is preferred as the deflection voltage required for a given rotation angle and the RF phase tolerance for a crab cavity are inversely proportional to the operating frequency. The short bunch spacing of the CLIC scheme and the high sensitivity of the crab cavity to dipole kicks demand very high dam** of the inter-bunch wakes, the major contributor to the luminosity loss of colliding bunches. This paper investigates the nature of the wakefields in the CLIC crab cavity and the possibility of using various dam** schemes to suppress them effectively.
△ Less
Submitted 19 June, 2009;
originally announced June 2009.
-
X-band crab cavities for the CLIC beam delivery system
Authors:
G. Burt,
P. K. Ambattu,
A. C. Dexter,
T. Abram,
V. Dolgashev,
S. Tantawi,
R. M. Jones
Abstract:
The CLIC machine incorporates a 20 mrad crossing angle at the IP to aid the extraction of spent beams. In order to recover the luminosity lost through the crossing angle a crab cavity is proposed to rotate the bunches prior to collision. The crab cavity is chosen to have the same frequency as the main linac (11.9942 GHz) as a compromise between size, phase stability requirements and beam loading…
▽ More
The CLIC machine incorporates a 20 mrad crossing angle at the IP to aid the extraction of spent beams. In order to recover the luminosity lost through the crossing angle a crab cavity is proposed to rotate the bunches prior to collision. The crab cavity is chosen to have the same frequency as the main linac (11.9942 GHz) as a compromise between size, phase stability requirements and beam loading. It is proposed to use a HE11 mode travelling wave structure as the CLIC crab cavity in order to minimise beam loading and mode separation. The position of the crab cavity close to the final focus enhances the effect of transverse wake-fields so effective wake-field dam** is required. A damped detuned structure is proposed to suppress and de-cohere the wake-field hence reducing their effect. Design considerations for the CLIC crab cavity will be discussed as well as the proposed high power testing of these structures at SLAC.
△ Less
Submitted 12 March, 2009;
originally announced March 2009.
-
Crab cavities for linear colliders
Authors:
G. Burt,
P. Ambattu,
R. Carter,
A. Dexter,
I. Tahir,
C. Beard,
M. Dykes,
P. Goudket,
A. Kalinin,
L. Ma,
P. McIntosh,
D. Shulte,
R. M. Jones,
L. Bellantoni,
B. Chase,
M. Church,
T. Khabouline,
A. Latina,
C. Adolphsen,
Z. Li,
A. Seryei,
L. Xiao
Abstract:
Crab cavities have been proposed for a wide number of accelerators and interest in crab cavities has recently increased after the successful operation of a pair of crab cavities in KEK-B. In particular crab cavities are required for both the ILC and CLIC linear colliders for bunch alignment. Consideration of bunch structure and size constraints favour a 3.9 GHz superconducting, multi-cell cavity…
▽ More
Crab cavities have been proposed for a wide number of accelerators and interest in crab cavities has recently increased after the successful operation of a pair of crab cavities in KEK-B. In particular crab cavities are required for both the ILC and CLIC linear colliders for bunch alignment. Consideration of bunch structure and size constraints favour a 3.9 GHz superconducting, multi-cell cavity as the solution for ILC, whilst bunch structure and beam-loading considerations suggest an X-band copper travelling wave structure for CLIC. These two cavity solutions are very different in design but share complex design issues. Phase stabilisation, beam loading, wakefields and mode dam** are fundamental issues for these crab cavities. Requirements and potential design solutions will be discussed for both colliders.
△ Less
Submitted 16 October, 2008;
originally announced October 2008.
-
Initial study on the shape optimisation of the CLIC crab cavity
Authors:
P. K. Ambattu,
G. Burt,
R. G. Carter,
A. C. Dexter,
R. M. Jones,
P. McIntosh
Abstract:
The compact linear collider (CLIC) requires a crab cavity to align bunches prior to collision. The bunch structure demands tight amplitude and phase tolerances of the RF fields inside the cavity, for the minimal luminosity loss. Beam loading effects require special attention as it is one potential sources of field errors in the cavity. In order to assist the amplitude and phase control, we propo…
▽ More
The compact linear collider (CLIC) requires a crab cavity to align bunches prior to collision. The bunch structure demands tight amplitude and phase tolerances of the RF fields inside the cavity, for the minimal luminosity loss. Beam loading effects require special attention as it is one potential sources of field errors in the cavity. In order to assist the amplitude and phase control, we propose a travelling wave (TW) structure with a high group velocity allowing rapid propagation of errors out of the system. Such a design makes the cavity structure significantly different from previous ones. This paper will look at the implications of this on other cavity parameters and the optimisation of the cavity geometry.
△ Less
Submitted 16 October, 2008;
originally announced October 2008.