-
Response of a Li-glass/multi-anode photomultiplier detector to collimated thermal-neutron beams
Authors:
E. Rofors,
N. Mauritzson,
H. Perrey,
R. Al Jebali,
J. R. M. Annand,
L. Boyd,
M. J. Christensen,
U. Clemens,
S. Desert,
R. Engels,
K. G. Fissum,
H. Frielinghaus,
C. Gheorghe,
R. Hall-Wilton,
S. Jaksch,
K. Kanaki,
S. Kazi,
G. Kemmerling,
I. Llamas Jansa,
V. Maulerova,
R. Montgomery,
T. Richter,
J. Scherzinger,
B. Seitz,
M. Shetty
Abstract:
The response of a position-sensitive Li-glass scintillator detector being developed for thermal-neutron detection with 6 mm position resolution has been investigated using collimated beams of thermal neutrons. The detector was moved perpendicularly through the neutron beams in 0.5 to 1.0 mm horizontal and vertical steps. Scintillation was detected in an 8 X 8 pixel multi-anode photomultiplier tube…
▽ More
The response of a position-sensitive Li-glass scintillator detector being developed for thermal-neutron detection with 6 mm position resolution has been investigated using collimated beams of thermal neutrons. The detector was moved perpendicularly through the neutron beams in 0.5 to 1.0 mm horizontal and vertical steps. Scintillation was detected in an 8 X 8 pixel multi-anode photomultiplier tube on an event-by-event basis. In general, several pixels registered large signals at each neutron-beam location. The number of pixels registering signal above a set threshold was investigated, with the maximization of the single-hit efficiency over the largest possible area of the detector as the primary goal. At a threshold of ~50% of the mean of the full-deposition peak, ~80% of the events were registered in a single pixel, resulting in an effective position resolution of ~5 mm in X and Y. Lower thresholds generally resulted in events demonstrating higher pixel multiplicities, but these events could also be localized with ~5 mm position resolution.
△ Less
Submitted 9 December, 2020; v1 submitted 13 October, 2020;
originally announced October 2020.
-
Response of a Li-glass/multi-anode photomultiplier detector to focused proton and deuteron beams
Authors:
E. Rofors,
J. Pallon,
R. Al Jebali,
J. R. M. Annand,
L. Boyd,
M. J. Christensen,
U. Clemens,
S. Desert,
M. Elfman,
R. Engels,
K. G. Fissum,
H. Frielinghaus,
R. Frost,
S. Gardner,
C. Gheorghe,
R. Hall-Wilton,
S. Jaksch,
K. Kanaki,
G. Kemmerling,
P. Kristiansson,
K. Livingston,
V. Maulerova,
N. Mauritzson,
R. Montgomery,
H. Perrey
, et al. (4 additional authors not shown)
Abstract:
The response of a position-sensitive Li-glass based scintillation detector to focused beams of 2.5 MeV protons and deuterons has been investigated. The beams were scanned across the detector in 0.5 mm horizontal and vertical steps perpendicular to the beams. Scintillation light was registered using an 8 by 8 pixel multi-anode photomultiplier tube. The signal amplitudes were recorded for each pixel…
▽ More
The response of a position-sensitive Li-glass based scintillation detector to focused beams of 2.5 MeV protons and deuterons has been investigated. The beams were scanned across the detector in 0.5 mm horizontal and vertical steps perpendicular to the beams. Scintillation light was registered using an 8 by 8 pixel multi-anode photomultiplier tube. The signal amplitudes were recorded for each pixel on an event-by-event basis. Several pixels generally registered considerable signals at each beam location. The number of pixels above set thresholds were investigated, with the optimization of the single-hit efficiency over the largest possible area as the goal. For both beams, at a threshold of ~50% of the mean of the full-deposition peak, ~80% of the events were registered in a single pixel, resulting in an effective position resolution of ~5 mm in X and Y.
△ Less
Submitted 18 May, 2020;
originally announced May 2020.
-
Response of a Li-glass/multi-anode photomultiplier detector to $α$-particles from $^{241}$Am
Authors:
E. Rofors,
H. Perrey,
R. Al Jebali,
J. R. M. Annand,
L. Boyd,
U. Clemens,
S. Desert,
R. Engels,
K. G. Fissum,
H. Frielinghaus,
C. Gheorghe,
R. Hall-Wilton,
S. Jaksch,
A. Jalgén,
K. Kanaki,
G. Kemmerling,
V. Maulerova,
N. Mauritzson,
R. Montgomery,
J. Scherzinger,
B. Seitz
Abstract:
The response of a position-sensitive Li-glass scintillator detector to $α$-particles from a collimated $^{241}$Am source scanned across the face of the detector has been measured. Scintillation light was read out by an 8 X 8 pixel multi-anode photomultiplier and the signal amplitude for each pixel has been recorded for every position on a scan. The pixel signal is strongly dependent on position an…
▽ More
The response of a position-sensitive Li-glass scintillator detector to $α$-particles from a collimated $^{241}$Am source scanned across the face of the detector has been measured. Scintillation light was read out by an 8 X 8 pixel multi-anode photomultiplier and the signal amplitude for each pixel has been recorded for every position on a scan. The pixel signal is strongly dependent on position and in general several pixels will register a signal (a hit) above a given threshold. The effect of this threshold on hit multiplicity is studied, with a view to optimize the single-hit efficiency of the detector.
△ Less
Submitted 19 December, 2018;
originally announced December 2018.
-
Cumulative Reports of the SoNDe Project July 2017
Authors:
Sebastian Jaksch,
Ralf Engels,
Günter Kemmerling,
Codin Gheorghe,
Philip Pahlsson,
Sylvain Désert,
Frederic Ott
Abstract:
This are the cumulated reports of the SoNDe detector Project as of July 2017. The contained reports are: - Report on the 1x1 module technical demonstrator - Report on used materials - Report on radiation hardness of components - Report on potential additional applications - Report on the 2x2 module technical demonstrator - Report on test results of the 2x2 technical demonstrator
This are the cumulated reports of the SoNDe detector Project as of July 2017. The contained reports are: - Report on the 1x1 module technical demonstrator - Report on used materials - Report on radiation hardness of components - Report on potential additional applications - Report on the 2x2 module technical demonstrator - Report on test results of the 2x2 technical demonstrator
△ Less
Submitted 26 July, 2017;
originally announced July 2017.
-
From Nanopores to Macropores: Fractal Morphology of Graphite
Authors:
Zhou Zhou,
Wim G. Bouwman,
Henk Schut,
Sylvain Desert,
Jacques Jestin,
Stefan Hartmann,
Catherine Pappas
Abstract:
We present a comprehensive structural characterization of two different highly pure nuclear graphites that compasses all relevant length scales from nanometers to sub-mm. This has been achieved by combining several experiments and neutron techniques: Small Angle Neutron Scattering (SANS), high-resolution Spin Echo SANS (SESANS) and neutron imaging. In this way it is possible to probe an extraordin…
▽ More
We present a comprehensive structural characterization of two different highly pure nuclear graphites that compasses all relevant length scales from nanometers to sub-mm. This has been achieved by combining several experiments and neutron techniques: Small Angle Neutron Scattering (SANS), high-resolution Spin Echo SANS (SESANS) and neutron imaging. In this way it is possible to probe an extraordinary broad range of 6 orders of magnitude in length from microscopic to macroscopic length scales. The results reveal a fractal structure that extends from $ \sim $ 0.6 nm to 0.6 mm and has surface and mass fractal dimensions both very close to 2.5, a value found for percolating clusters and fractured ranked surfaces in 3D.
△ Less
Submitted 18 September, 2015;
originally announced September 2015.
-
A double supermirror monochromator for neutron instrumentation at LLB
Authors:
Sylvain Desert,
Vincent Thevenot,
Andre Gabriel,
Patrice Permingeat,
Julian Oberdisse,
Annie Brulet
Abstract:
The design and characteristics of a double supermirror monochromator for neutron instrumentation at the Laboratoire Leon Brillouin is described. The aim of this monochromator is to reduce the intense gamma-radiation produced by conventional velocity selectors and to avoid a direct view of the guide while kee** a comparable neutron transmission (higher than 70%). The monochromator offers a cont…
▽ More
The design and characteristics of a double supermirror monochromator for neutron instrumentation at the Laboratoire Leon Brillouin is described. The aim of this monochromator is to reduce the intense gamma-radiation produced by conventional velocity selectors and to avoid a direct view of the guide while kee** a comparable neutron transmission (higher than 70%). The monochromator offers a continuous choice of wavelength selection in the range 0.5 to 2 nm.
△ Less
Submitted 19 October, 2007;
originally announced October 2007.
-
The new very small angle neutron scattering spectrometer at Laboratoire Leon Brillouin
Authors:
Sylvain Desert,
Vincent Thevenot,
Julian Oberdisse,
Annie Brulet
Abstract:
The design and characteristics of the new very small angle neutron scattering spectrometer under construction at the Laboratoire Leon Brillouin is described. Its goal is to extend the range of scattering vectors magnitudes towards 2x10{-4} /A. The unique feature of this new spectrometer is a high resolution two dimensional image plate detector sensitive to neutrons. The wavelength selection is a…
▽ More
The design and characteristics of the new very small angle neutron scattering spectrometer under construction at the Laboratoire Leon Brillouin is described. Its goal is to extend the range of scattering vectors magnitudes towards 2x10{-4} /A. The unique feature of this new spectrometer is a high resolution two dimensional image plate detector sensitive to neutrons. The wavelength selection is achieved by a double reflection supermirror monochromator and the collimator uses a novel multibeam design.
△ Less
Submitted 12 June, 2007;
originally announced June 2007.