-
Low-profile Button Sensor Antenna Design for Wireless Medical Body Area Networks
Authors:
Shahid M Ali,
Cheab Sovuthy,
Sima Noghanian,
Qammer H. Abbasi,
Tatjana Asenova,
Peter Derleth,
Alex Casson,
Tughrul Arslan,
Amir Hussain
Abstract:
A button sensor antenna for wireless medical body area networks (WMBAN) is presented, which works through the IEEE 802.11b/g/n standard. Due to strong interaction between the sensor antenna and the body, an innovative robust system is designed with a small footprint that can serve on- and off-body healthcare applications. The measured and simulated results are in good agreement. The design offers…
▽ More
A button sensor antenna for wireless medical body area networks (WMBAN) is presented, which works through the IEEE 802.11b/g/n standard. Due to strong interaction between the sensor antenna and the body, an innovative robust system is designed with a small footprint that can serve on- and off-body healthcare applications. The measured and simulated results are in good agreement. The design offers a wide range of omnidirectional radiation patterns in free space, with a reflection coefficient (S11) of -29.30 (-30.97) dB in the lower (upper) bands. S11 reaches up to -23.07 (-27.07) dB and -30.76 (-31.12) dB, respectively, on the human body chest and arm. The Specific Absorption Rate (SAR) values are below the regulatory limitations for both 1-gram (1.6 W/Kg) and 10-gram tissues (2.0 W/Kg). Experimental tests of the read range validate the results of a maximum coverage range of 40 meters.
△ Less
Submitted 8 February, 2022;
originally announced March 2022.
-
Design of Flexible Meander Line Antenna for Healthcare for Wireless Medical Body Area Networks
Authors:
Shahid M Ali,
Cheab Sovuthy,
Sima Noghanian,
Qammer H. Abbasi,
Tatjana Asenova,
Peter Derleth,
Alex Casson,
Tughrul Arslan,
Amir Hussain
Abstract:
A flexible meander line monopole antenna (MMA) is presented in this paper. The antenna can be worn for on-and off-body applications. The overall dimension of the MMA is 37 mm x 50 mm x2.37 mm3. The MMA was manufactured and measured, and the results matched with simulation results. The MMA design shows a bandwidth of up to 1282.4 (450.5) MHz and provides gains of 3.03 (4.85) dBi in the lower and up…
▽ More
A flexible meander line monopole antenna (MMA) is presented in this paper. The antenna can be worn for on-and off-body applications. The overall dimension of the MMA is 37 mm x 50 mm x2.37 mm3. The MMA was manufactured and measured, and the results matched with simulation results. The MMA design shows a bandwidth of up to 1282.4 (450.5) MHz and provides gains of 3.03 (4.85) dBi in the lower and upper operating bands, respectively, showing omnidirectional radiation patterns in free space. While worn on the chest or arm, bandwidths as high as 688.9 (500.9) MHz and 1261.7 (524.2) MHz, and the gains of 3.80 (4.67) dBi and 3.00 (4.55) dBi were observed. The experimental measurements of the read range confirmed the results of the coverage range of up to 11 meters.
△ Less
Submitted 8 February, 2022;
originally announced February 2022.
-
AV Speech Enhancement Challenge using a Real Noisy Corpus
Authors:
Mandar Gogate,
Ahsan Adeel,
Kia Dashtipour,
Peter Derleth,
Amir Hussain
Abstract:
This paper presents, a first of its kind, audio-visual (AV) speech enhacement challenge in real-noisy settings. A detailed description of the AV challenge, a novel real noisy AV corpus (ASPIRE), benchmark speech enhancement task, and baseline performance results are outlined. The latter are based on training a deep neural architecture on a synthetic mixture of Grid corpus and ChiME3 noises (consis…
▽ More
This paper presents, a first of its kind, audio-visual (AV) speech enhacement challenge in real-noisy settings. A detailed description of the AV challenge, a novel real noisy AV corpus (ASPIRE), benchmark speech enhancement task, and baseline performance results are outlined. The latter are based on training a deep neural architecture on a synthetic mixture of Grid corpus and ChiME3 noises (consisting of bus, pedestrian, cafe, and street noises) and testing on the ASPIRE corpus. Subjective evaluations of five different speech enhancement algorithms (including SEAGN, spectrum subtraction (SS) , log-minimum mean-square error (LMMSE), audio-only CochleaNet, and AV CochleaNet) are presented as baseline results. The aim of the multi-modal challenge is to provide a timely opportunity for comprehensive evaluation of novel AV speech enhancement algorithms, using our new benchmark, real-noisy AV corpus and specified performance metrics. This will promote AV speech processing research globally, stimulate new ground-breaking multi-modal approaches, and attract interest from companies, academics and researchers working in AV speech technologies and applications. We encourage participants (through a challenge website sign-up) from both the speech and hearing research communities, to benefit from their complementary approaches to AV speech in noise processing.
△ Less
Submitted 30 September, 2019;
originally announced October 2019.