Measuring Physical and Electrical Parameters in Free-Living Subjects: Motivating an Instrument to Characterize Analytes of Clinical Importance in Blood Samples
Authors:
Barry K. Gilbert,
Clifton R. Haider,
Daniel J. Schwab,
Gary S. Delp
Abstract:
Significance: A path is described to increase the sensitivity and accuracy of body-worn devices used to monitor patient health. This path supports improved health management. A wavelength-choice algorithm developed at Mayo demonstrates that critical biochemical analytes can be assessed using accurate optical absorption curves over a wide range of wavelengths. Aim: Combine the requirements for moni…
▽ More
Significance: A path is described to increase the sensitivity and accuracy of body-worn devices used to monitor patient health. This path supports improved health management. A wavelength-choice algorithm developed at Mayo demonstrates that critical biochemical analytes can be assessed using accurate optical absorption curves over a wide range of wavelengths. Aim: Combine the requirements for monitoring cardio/electrical, movement, activity, gait, tremor, and critical biochemical analytes including hemoglobin makeup in the context of body-worn sensors. Use the data needed to characterize clinically important analytes in blood samples to drive instrument requirements. Approach: Using data and knowledge gained over previously separate research threads, some providing currently usable results from more than eighty years back, determine analyte characteristics needed to design sensitive and accurate multiuse measurement and recording units. Results: Strategies for wavelength selection are detailed. Fine-grained, broad-spectrum measurement of multiple analytes transmission, absorption, and anisotropic scattering are needed. Post-Beer-Lambert, using the propagation of error from small variations, and utility functions that include costs and systemic error sources, improved measurements can be performed. Conclusions: The Mayo Double-Integrating Sphere Spectrophotometer (referred hereafter as MDISS), as described in the companion report arXiv:2212.08763, produces the data necessary for optimal component choice. These data can provide for robust enhancement of the sensitivity, cost, and accuracy of body-worn medical sensors. Keywords: Bio-Analyte, Spectrophotometry, Body-worn monitor, Propagation of error, Double-Integrating Sphere, Mt. Everest medical measurements, O2SAT
Please see also arXiv:2212.08763
△ Less
Submitted 6 January, 2023; v1 submitted 2 January, 2023;
originally announced January 2023.
An Experimental Double-Integrating Sphere Spectrophotometer for In Vitro Optical Analysis of Blood and Tissue Samples, Including Examples of Analyte Measurement Results
Authors:
Daniel J. Schwab,
Clifton R. Haider,
Gary S. Delp,
Stefan K. Grebe,
Barry K. Gilbert
Abstract:
Data-driven science requires data to drive it. Being able to make accurate and precise measurement of biomaterials in the body means that medical assessments can be more accurate. There are differences between how blood absorbs and how it reflects light. The Mayo Clinic's Double-Integrating Sphere Spectrophotometer (MDISS) is an automated measurement device that detects both scattered and direct e…
▽ More
Data-driven science requires data to drive it. Being able to make accurate and precise measurement of biomaterials in the body means that medical assessments can be more accurate. There are differences between how blood absorbs and how it reflects light. The Mayo Clinic's Double-Integrating Sphere Spectrophotometer (MDISS) is an automated measurement device that detects both scattered and direct energy as it passes through a sample in a holder. It can make over 1,200 evenly spaced color measurements from the very deep purple (300-nm) through the visible light spectrum into the near infrared (2800-nm). The MDISS samples measured have been also measured by commercial laboratory equipment. The MDISS measurements are as accurate and more precise than those devices now in use.
With so many measurements to be made during the time that the sample remains undegraded, mechanical and data collection automation was required. The MDISS sample holders include different thicknesses, versions that can operate at high pressure (such as divers may experience), and versions that can pump and rotate the measured material to maintain consistency of measurement. Although the data obtained are preliminary, they have potential to guide the design of new devices for more accurate assessments. There is an extensive "lessons learned" section. Please also see the companion report arXiv:2301.00938
△ Less
Submitted 4 January, 2023; v1 submitted 16 December, 2022;
originally announced December 2022.