A Smart Cushion for Real-Time Heart Rate Monitoring
Authors:
Chacko John Deepu,
Zhihao Chen,
Ju Teng Teo,
Soon Huat Ng,
Xiefeng Yang,
Yong Lian
Abstract:
This paper presents a smart cushion for real time heart rate monitoring. The cushion comprises of an integrated micro-bending fiber sensor, which records the BCG (Ballistocardiogram) signal without direct skin-electrode contact, and an optical transceiver that does signal amplification, digitization, and pre-filtering. To remove the artifacts and extract heart rate from BCG signal, a computational…
▽ More
This paper presents a smart cushion for real time heart rate monitoring. The cushion comprises of an integrated micro-bending fiber sensor, which records the BCG (Ballistocardiogram) signal without direct skin-electrode contact, and an optical transceiver that does signal amplification, digitization, and pre-filtering. To remove the artifacts and extract heart rate from BCG signal, a computationally efficient heart rate detection algorithm is developed. The system doesn't require any pre-training and is highly responsive with the outputs updated every 3 sec and initial response within first 10 sec. Tests conducted on human subjects show the detected heart rate closely matches the one from a commercial SpO2 device.
△ Less
Submitted 29 September, 2014;
originally announced September 2014.
-
An ECG-on-Chip for Wearable Cardiac Monitoring Devices
Authors:
C. J. Deepu,
X. Y. Xu,
X. D. Zou,
L. B. Yao,
Y. Lian
Abstract:
This paper describes a highly integrated, low power chip solution for ECG signal processing in wearable devices. The chip contains an instrumentation amplifier with programmable gain, a band-pass filter, a 12-bit SAR ADC, a novel QRS detector, 8K on-chip SRAM, and relevant control circuitry and CPU interfaces. The analog front end circuits accurately senses and digitizes the raw ECG signal, which…
▽ More
This paper describes a highly integrated, low power chip solution for ECG signal processing in wearable devices. The chip contains an instrumentation amplifier with programmable gain, a band-pass filter, a 12-bit SAR ADC, a novel QRS detector, 8K on-chip SRAM, and relevant control circuitry and CPU interfaces. The analog front end circuits accurately senses and digitizes the raw ECG signal, which is then filtered to extract the QRS. The sampling frequency used is 256 Hz. ECG samples are buffered locally on an asynchronous FIFO and is read out using a faster clock, as and when it is required by the host CPU via an SPI interface. The chip was designed and implemented in 0.35um standard CMOS process. The analog core operates at 1V while the digital circuits and SRAM operate at 3.3V. The chip total core area is 5.74 mm^2 and consumes 9.6uW. Small size and low power consumption make this design suitable for usage in wearable heart monitoring devices.
△ Less
Submitted 29 September, 2014;
originally announced September 2014.
-
An ECG-on-Chip with 535-nW/Channel Integrated Lossless Data Compressor for Wireless Sensors
Authors:
C. J. Deepu,
X. Zhang,
W. -S. Liew,
D. L. T. Wong,
Y. Lian
Abstract:
This paper presents a low-power ECG recording system-on-chip (SoC) with on-chip low-complexity lossless ECG compression for data reduction in wireless/ambulatory ECG sensor devices. The chip uses a linear slope predictor for data compression, and incorporates a novel low-complexity dynamic coding-packaging scheme to frame the prediction error into fixed-length 16-bit format. The proposed technique…
▽ More
This paper presents a low-power ECG recording system-on-chip (SoC) with on-chip low-complexity lossless ECG compression for data reduction in wireless/ambulatory ECG sensor devices. The chip uses a linear slope predictor for data compression, and incorporates a novel low-complexity dynamic coding-packaging scheme to frame the prediction error into fixed-length 16-bit format. The proposed technique achieves an average compression ratio of 2.25x on MIT/BIH ECG database. Implemented in a standard 0.35 um process, the compressor uses 0.565K gates/channel occupying 0.4 mm2 for four channels, and consumes 535 nW/channel at 2.4 V for ECG sampled at 512 Hz. Small size and ultra-low power consumption makes the proposed technique suitable for wearable ECG sensor applications.
△ Less
Submitted 29 September, 2014;
originally announced September 2014.
-
An ECG-SoC with 535nW/channel lossless data compression for wearable sensors
Authors:
C. J. Deepu
Abstract:
This paper presents a low power ECG recording Sys-tem-on-Chip (SoC) with on-chip low complexity lossless ECG compression for data reduction in wireless/ambulatory ECG sensor devices. The proposed algorithm uses a linear slope predictor to estimate the ECG samples, and uses a novel low complexity dynamic coding-packaging scheme to frame the resulting estimation error into fixed-length 16-bit format…
▽ More
This paper presents a low power ECG recording Sys-tem-on-Chip (SoC) with on-chip low complexity lossless ECG compression for data reduction in wireless/ambulatory ECG sensor devices. The proposed algorithm uses a linear slope predictor to estimate the ECG samples, and uses a novel low complexity dynamic coding-packaging scheme to frame the resulting estimation error into fixed-length 16-bit format. The proposed technique achieves an average compression ratio of 2.25x on MIT/BIH ECG database. Implemented in 0.35 μm process, the compressor uses 0.565 K gates/channel occupying 0.4 mm2 for 4-channel, and consumes 535 nW/channel at 2.4V for ECG sampled at 512 Hz. Small size and ultra-low power consumption makes the proposed technique suitable for wearable ECG sensor application.
△ Less
Submitted 19 July, 2014;
originally announced July 2014.