A new upper limit on the axion-photon coupling with an extended CAST run with a Xe-based Micromegas detector
Authors:
CAST Collaboration,
K. Altenmüller,
V. Anastassopoulos,
S. Arguedas-Cuendis,
S. Aune,
J. Baier,
K. Barth,
H. Bräuninger,
G. Cantatore,
F. Caspers,
J. F. Castel,
S. A. Çetin,
F. Christensen,
C. Cogollos,
T. Dafni,
M. Davenport,
T. A. Decker,
K. Desch,
D. Díez-Ibáñez,
B. Döbrich,
E. Ferrer-Ribas,
H. Fischer,
W. Funk,
J. Galán,
J. A. García
, et al. (40 additional authors not shown)
Abstract:
Hypothetical axions provide a compelling explanation for dark matter and could be emitted from the hot solar interior. The CERN Axion Solar Telescope (CAST) has been searching for solar axions via their back conversion to X-ray photons in a 9-T 10-m long magnet directed towards the Sun. We report on an extended run with the IAXO (International Axion Observatory) pathfinder detector, doubling the p…
▽ More
Hypothetical axions provide a compelling explanation for dark matter and could be emitted from the hot solar interior. The CERN Axion Solar Telescope (CAST) has been searching for solar axions via their back conversion to X-ray photons in a 9-T 10-m long magnet directed towards the Sun. We report on an extended run with the IAXO (International Axion Observatory) pathfinder detector, doubling the previous exposure time. The detector was operated with a xenon-based gas mixture for part of the new run, providing technical insights for future detector configurations in IAXO. No counts are detected in the 95\% signal-encircling region during the new run, while one is expected. The new data improve the axion-photon coupling limit to 5.7$\times 10^{-11}\,$GeV$^{-1}$ at 95\% C.L., the most restrictive experimental limit to date.
△ Less
Submitted 24 June, 2024;
originally announced June 2024.
-
New CAST Limit on the Axion-Photon Interaction
Authors:
CAST collaboration,
V. Anastassopoulos,
S. Aune,
K. Barth,
A. Belov,
H. Brauninger,
G. Cantatore,
J. M. Carmona,
J. F. Castel,
S. A. Cetin,
F. Christensen,
J. I. Collar,
T. Dafni,
M. Davenport,
T. A. Decker,
A. Dermenev,
K. Desch,
C. Eleftheriadis,
G. Fanourakis,
E. Ferrer-Ribas,
H. Fischer,
J. A. Garcia,
A. Gardikiotis,
J. G. Garza,
E. N. Gazis
, et al. (42 additional authors not shown)
Abstract:
During 2003--2015, the CERN Axion Solar Telescope (CAST) has searched for $a\toγ$ conversion in the 9 T magnetic field of a refurbished LHC test magnet that can be directed toward the Sun. In its final phase of solar axion searches (2013--2015), CAST has returned to evacuated magnet pipes, which is optimal for small axion masses. The absence of a significant signal above background provides a worl…
▽ More
During 2003--2015, the CERN Axion Solar Telescope (CAST) has searched for $a\toγ$ conversion in the 9 T magnetic field of a refurbished LHC test magnet that can be directed toward the Sun. In its final phase of solar axion searches (2013--2015), CAST has returned to evacuated magnet pipes, which is optimal for small axion masses. The absence of a significant signal above background provides a world leading limit of $g_{aγ} < 0.66 \times 10^{-10} {\rm GeV}^{-1}$ (95% C.L.) on the axion-photon coupling strength for $m_a \lesssim 0.02$ eV. Compared with the first vacuum phase (2003--2004), the sensitivity was vastly increased with low-background x-ray detectors and a new x-ray telescope. These innovations also serve as pathfinders for a possible next-generation axion helioscope.
△ Less
Submitted 20 December, 2017; v1 submitted 5 May, 2017;
originally announced May 2017.
-
A Micromegas-based low-background x-ray detector coupled to a slumped-glass telescope for axion research
Authors:
F. Aznar,
J. Castel,
F. E. Christensen,
T. Dafni,
T. A. Decker,
E. Ferrer-Ribas,
J. A. Garcia,
I. Giomataris,
J. G. Gracia,
C. J. Hailey,
R. M. Hill,
F. J. Iguaz,
I. G. Irastorza,
A. C. Jakobsen,
G. Luzon,
H. Mirallas,
T. Papaevangelou,
M. J. Pivovaroff,
J. Ruz,
T. Vafeiadis,
J. K. Vogel
Abstract:
We report on the design, construction and operation of a low background x-ray detection line composed of a shielded Micromegas (micromesh gaseous structure) detector of the microbulk technique. The detector is made from radiopure materials and is placed at the focal point of a $\sim$~5 cm diameter, 1.3 m focal-length, cone-approximation Wolter I x-ray telescope (XRT) comprised of thermally-formed…
▽ More
We report on the design, construction and operation of a low background x-ray detection line composed of a shielded Micromegas (micromesh gaseous structure) detector of the microbulk technique. The detector is made from radiopure materials and is placed at the focal point of a $\sim$~5 cm diameter, 1.3 m focal-length, cone-approximation Wolter I x-ray telescope (XRT) comprised of thermally-formed (or "slumped") glass substrates deposited with multilayer coatings. The system has been conceived as a technological pathfinder for the future International Axion Observatory (IAXO), as it combines two of the techniques (optic and detector) proposed in the conceptual design of the project. It is innovative for two reasons: it is the first time an x-ray optic has been designed and fabricated specifically for axion research, and the first time a Micromegas detector has been operated with an x-ray optic. The line has been installed at one end of the CERN Axion Solar Telescope (CAST) magnet and is currently looking for solar axions. The combination of the XRT and Micromegas detector provides the best signal-to-noise ratio obtained so far by any detection system of the CAST experiment with a background rate of 5.4$\times$10$^{-3}\;$counts per hour in the energy region-of-interest and signal spot area.
△ Less
Submitted 21 September, 2015;
originally announced September 2015.