-
Nematicity of a Magnetic Helix
Authors:
R. Tumbleson,
S. A. Morley,
E. Hollingworth,
A. Singh,
T. Bayaraa,
N. G. Burdet,
A. U. Saleheen,
M. R. McCarter,
D. Raftrey,
R. J. Pandolfi,
V. Esposito,
G. L. Dakovski,
F. -J. Decker,
A. H. Reid,
T. A. Assefa,
P. Fischer,
S. M. Griffin,
S. D. Kevan,
F. Hellman,
J. J. Turner,
S. Roy
Abstract:
A system that possesses translational symmetry but breaks orientational symmetry is known as a nematic phase. While there are many examples of nematic phases in a wide range of contexts, such as in liquid crystals, complex oxides, and superconductors, of particular interest is the magnetic analogue, where the spin, charge, and orbital degrees of freedom of the electron are intertwined. The difficu…
▽ More
A system that possesses translational symmetry but breaks orientational symmetry is known as a nematic phase. While there are many examples of nematic phases in a wide range of contexts, such as in liquid crystals, complex oxides, and superconductors, of particular interest is the magnetic analogue, where the spin, charge, and orbital degrees of freedom of the electron are intertwined. The difficulty of spin nematics is the unambiguous realization and characterization of the phase. Here we present an entirely new type of magnetic nematic phase, which replaces the basis of individual spins with magnetic helices. The helical basis allows for the direct measurement of the order parameters with soft X-ray scattering and a thorough characterization of the nematic phase and its thermodynamic transitions. We discover two distinct nematic phases with unique spatio-temporal correlation signatures. Using coherent X-ray methods, we find that near the phase boundary between the two nematic phases, fluctuations coexist on the timescale of both seconds and sub-nanoseconds. Additionally, we have determined that the fluctuations occur simultaneously with a reorientation of the magnetic helices, indicating that there is spontaneous symmetry breaking and new degrees of freedom become available. Our results provide a novel framework for characterizing exotic phases and the phenomena presented can be mapped onto a broad class of physical systems.
△ Less
Submitted 19 April, 2024;
originally announced April 2024.
-
Direct Experimental Observation of the Gas Filamentation Effect using a Two-bunch X-ray FEL Beam
Authors:
Y. Feng,
D. W. Schafer,
S. Song,
Y. Sun,
D. Zhu,
J. Krzywinski,
A. Robert,
J. Wu,
F. -J. Decker
Abstract:
We report the experimental observation of the filamentation effect in gas devices designed for X-ray Free-electron Lasers. The measurements were carried out at the Linac Coherent Light Source on the X-ray Correlation Spectroscopy (XCS) instrument using a Two-bunch FEL beam at 6.5 keV with 122.5 ns separation passing through an Argon gas cell. The relative intensities of the two pulses of the Two-b…
▽ More
We report the experimental observation of the filamentation effect in gas devices designed for X-ray Free-electron Lasers. The measurements were carried out at the Linac Coherent Light Source on the X-ray Correlation Spectroscopy (XCS) instrument using a Two-bunch FEL beam at 6.5 keV with 122.5 ns separation passing through an Argon gas cell. The relative intensities of the two pulses of the Two-bunch beam were measured, after and before the gas cell, from the X-ray scattering off thin targets by using fast diodes with sufficient temporal resolution. It was found that the after-to-before ratio of the intensities of the second pulse was consistently higher than that of the first pulse, revealing lower effective attenuation of the gas cell due to the heating and subsequent gas density reduction in the beam path by the first pulse. This measurement is important in guiding the design and/or mitigating the adverse effect in gas devices for high repetition-rate FELs such as the LCLS-II and the European XFEL or other future high repetition-rate upgrade to existing FEL facilities
△ Less
Submitted 27 May, 2017;
originally announced June 2017.
-
Transverse emittance measurements on an S-band photoinjector rf electron gun
Authors:
J. F. Schmerge,
P. R. Bolton,
J. E. Clendenin,
F. -J. Decker,
D. H. Dowell,
S. M. Gierman,
C. G. Limborg,
B. F. Murphy
Abstract:
Proposed fourth generation light sources using SASE FELs to generate short pulse, coherent, X-rays require demonstration of high brightness electron sources. The Gun Test Facility (GTF) at SLAC was built to test high brightness sources for the proposed Linac Coherent Light Source at SLAC. The transverse emittance measurements are made at nearly 30 MeV by measuring the spot size on a YAG screen u…
▽ More
Proposed fourth generation light sources using SASE FELs to generate short pulse, coherent, X-rays require demonstration of high brightness electron sources. The Gun Test Facility (GTF) at SLAC was built to test high brightness sources for the proposed Linac Coherent Light Source at SLAC. The transverse emittance measurements are made at nearly 30 MeV by measuring the spot size on a YAG screen using the quadrupole scan technique. The emittance was measured to vary from 1 to 3.5 mm-mrad as the charge is increased from 50 to 350 pC using a laser pulse width of 2 ps FWHM. The measurements are in good agreement with simulation results using the LANL version of PARMELA.
△ Less
Submitted 3 November, 2001;
originally announced November 2001.
-
Upgrade of the PEP-II Low Beta Optics
Authors:
Y. Nosochkov,
M. Biagini,
Y. Cai,
F. -J. Decker,
M. H. R. Donald,
S. Ecklund,
A. Fisher,
W. Kozanecki,
P. Krejcik,
A. Kulikov,
M. Minty,
I. Reichel,
J. Seeman,
M. Sullivan,
U. Wienands,
Y. Yan
Abstract:
The successful commissioning and operation of the PEP-II asymmetric e+e- collider motivated further studies to increase luminosity. In this paper, we discuss a modification of the PEP-II lattice to reduce the vertical beta function at the Interaction Point (IP) from the design value of 1.5cm to 1.0cm. This could potentially reduce the colliding beam size, increase particle density at the IP and…
▽ More
The successful commissioning and operation of the PEP-II asymmetric e+e- collider motivated further studies to increase luminosity. In this paper, we discuss a modification of the PEP-II lattice to reduce the vertical beta function at the Interaction Point (IP) from the design value of 1.5cm to 1.0cm. This could potentially reduce the colliding beam size, increase particle density at the IP and the probability of beam-beam interactions. In this paper, we outline the optics modifications, discuss tracking simulations, and overview machine implementation.
△ Less
Submitted 29 June, 2000;
originally announced June 2000.