-
Testbeam results of irradiated SiGe BiCMOS monolithic silicon pixel detector without internal gain layer
Authors:
T. Moretti,
M. Milanesio,
R. Cardella,
T. Kugathasan,
A. Picardi,
I. Semendyaev,
M. Elviretti,
H. Rücker,
K. Nakamura,
Y. Takubo,
M. Togawa,
F. Cadoux,
R. Cardarelli,
L. Cecconi,
S. Débieux,
Y. Favre,
C. A. Fenoglio,
D. Ferrere,
S. Gonzalez-Sevilla,
L. Iodice,
R. Kotitsa,
C. Magliocca,
M. Nessi,
A. Pizarro-Medina,
J. Sabater Iglesias
, et al. (5 additional authors not shown)
Abstract:
Samples of the monolithic silicon pixel ASIC prototype produced in 2022 within the framework of the Horizon 2020 MONOLITH ERC Advanced project were irradiated with 70 MeV protons up to a fluence of 1 x 1016 neq/cm2, and then tested using a beam of 120 GeV/c pions. The ASIC contains a matrix of 100 μm pitch hexagonal pixels, readout out by low noise and very fast frontend electronics produced in a…
▽ More
Samples of the monolithic silicon pixel ASIC prototype produced in 2022 within the framework of the Horizon 2020 MONOLITH ERC Advanced project were irradiated with 70 MeV protons up to a fluence of 1 x 1016 neq/cm2, and then tested using a beam of 120 GeV/c pions. The ASIC contains a matrix of 100 μm pitch hexagonal pixels, readout out by low noise and very fast frontend electronics produced in a 130 nm SiGe BiCMOS technology process. The dependence on the proton fluence of the efficiency and the time resolution of this prototype was measured with the frontend electronics operated at a power density between 0.13 and 0.9 W/cm2. The testbeam data show that the detection efficiency of 99.96% measured at sensor bias voltage of 200 V before irradiation becomes 96.2% after a fluence of 1 x 1016 neq/cm2. An increase of the sensor bias voltage to 300 V provides an efficiency to 99.7% at that proton fluence. The timing resolution of 20 ps measured before irradiation rises for a proton fluence of 1 x 1016 neq/cm2 to 53 and 45 ps at HV = 200 and 300 V, respectively.
△ Less
Submitted 21 June, 2024; v1 submitted 19 April, 2024;
originally announced April 2024.
-
First Measurement of the $ν_e$ and $ν_μ$ Interaction Cross Sections at the LHC with FASER's Emulsion Detector
Authors:
FASER Collaboration,
Roshan Mammen Abraham,
John Anders,
Claire Antel,
Akitaka Ariga,
Tomoko Ariga,
Jeremy Atkinson,
Florian U. Bernlochner,
Tobias Boeckh,
Jamie Boyd,
Lydia Brenner,
Angela Burger,
Franck Cadoux,
Roberto Cardella,
David W. Casper,
Charlotte Cavanagh,
Xin Chen,
Andrea Coccaro,
Stephane Debieux,
Monica D'Onofrio,
Ansh Desai,
Sergey Dmitrievsky,
Sinead Eley,
Yannick Favre,
Deion Fellers
, et al. (80 additional authors not shown)
Abstract:
This paper presents the first results of the study of high-energy electron and muon neutrino charged-current interactions in the FASER$ν$ emulsion/tungsten detector of the FASER experiment at the LHC. A subset of the FASER$ν$ volume, which corresponds to a target mass of 128.6~kg, was exposed to neutrinos from the LHC $pp$ collisions with a centre-of-mass energy of 13.6~TeV and an integrated lumin…
▽ More
This paper presents the first results of the study of high-energy electron and muon neutrino charged-current interactions in the FASER$ν$ emulsion/tungsten detector of the FASER experiment at the LHC. A subset of the FASER$ν$ volume, which corresponds to a target mass of 128.6~kg, was exposed to neutrinos from the LHC $pp$ collisions with a centre-of-mass energy of 13.6~TeV and an integrated luminosity of 9.5 fb$^{-1}$. Applying stringent selections requiring electrons with reconstructed energy above 200~GeV, four electron neutrino interaction candidate events are observed with an expected background of $0.025^{+0.015}_{-0.010}$, leading to a statistical significance of 5.2$σ$. This is the first direct observation of electron neutrino interactions at a particle collider. Eight muon neutrino interaction candidate events are also detected, with an expected background of $0.22^{+0.09}_{-0.07}$, leading to a statistical significance of 5.7$σ$. The signal events include neutrinos with energies in the TeV range, the highest-energy electron and muon neutrinos ever detected from an artificial source. The energy-independent part of the interaction cross section per nucleon is measured over an energy range of 560--1740 GeV (520--1760 GeV) for $ν_e$ ($ν_μ$) to be $(1.2_{-0.7}^{+0.8}) \times 10^{-38}~\mathrm{cm}^{2}\,\mathrm{GeV}^{-1}$ ($(0.5\pm0.2) \times 10^{-38}~\mathrm{cm}^{2}\,\mathrm{GeV}^{-1}$), consistent with Standard Model predictions. These are the first measurements of neutrino interaction cross sections in those energy ranges.
△ Less
Submitted 19 March, 2024;
originally announced March 2024.
-
Neutrino Rate Predictions for FASER
Authors:
FASER Collaboration,
Roshan Mammen Abraham,
John Anders,
Claire Antel,
Akitaka Ariga,
Tomoko Ariga,
Jeremy Atkinson,
Florian U. Bernlochner,
Tobias Boeckh,
Jamie Boyd,
Lydia Brenner,
Angela Burger,
Franck Cadoux,
Roberto Cardella,
David W. Casper,
Charlotte Cavanagh,
Xin Chen,
Andrea Coccaro,
Stephane Débieux,
Monica D'Onofrio,
Ansh Desai,
Sergey Dmitrievsky,
Sinead Eley,
Yannick Favre,
Deion Fellers
, et al. (75 additional authors not shown)
Abstract:
The Forward Search Experiment (FASER) at CERN's Large Hadron Collider (LHC) has recently directly detected the first collider neutrinos. Neutrinos play an important role in all FASER analyses, either as signal or background, and it is therefore essential to understand the neutrino event rates. In this study, we update previous simulations and present prescriptions for theoretical predictions of ne…
▽ More
The Forward Search Experiment (FASER) at CERN's Large Hadron Collider (LHC) has recently directly detected the first collider neutrinos. Neutrinos play an important role in all FASER analyses, either as signal or background, and it is therefore essential to understand the neutrino event rates. In this study, we update previous simulations and present prescriptions for theoretical predictions of neutrino fluxes and cross sections, together with their associated uncertainties. With these results, we discuss the potential for possible measurements that could be carried out in the coming years with the FASER neutrino data to be collected in LHC Run 3 and Run 4.
△ Less
Submitted 13 June, 2024; v1 submitted 20 February, 2024;
originally announced February 2024.
-
Radiation Tolerance of SiGe BiCMOS Monolithic Silicon Pixel Detectors without Internal Gain Layer
Authors:
M. Milanesio,
L. Paolozzi,
T. Moretti,
R. Cardella,
T. Kugathasan,
F. Martinelli,
A. Picardi,
I. Semendyaev,
S. Zambito,
K. Nakamura,
Y. Tabuko,
M. Togawa,
M. Elviretti,
H. Rücker,
F. Cadoux,
R. Cardarelli,
S. Débieux,
Y. Favre,
C. A. Fenoglio,
D. Ferrere,
S. Gonzalez-Sevilla,
L. Iodice,
R. Kotitsa,
C. Magliocca,
M. Nessi
, et al. (5 additional authors not shown)
Abstract:
A monolithic silicon pixel prototype produced for the MONOLITH ERC Advanced project was irradiated with 70 MeV protons up to a fluence of 1 x 10^16 1 MeV n_eq/cm^2. The ASIC contains a matrix of hexagonal pixels with 100 μm pitch, readout by low-noise and very fast SiGe HBT frontend electronics. Wafers with 50 μm thick epilayer with a resistivity of 350 Ωcm were used to produce a fully depleted se…
▽ More
A monolithic silicon pixel prototype produced for the MONOLITH ERC Advanced project was irradiated with 70 MeV protons up to a fluence of 1 x 10^16 1 MeV n_eq/cm^2. The ASIC contains a matrix of hexagonal pixels with 100 μm pitch, readout by low-noise and very fast SiGe HBT frontend electronics. Wafers with 50 μm thick epilayer with a resistivity of 350 Ωcm were used to produce a fully depleted sensor. Laboratory tests conducted with a 90Sr source show that the detector works satisfactorily after irradiation. The signal-to-noise ratio is not seen to change up to fluence of 6 x 10^14 n_eq /cm^2 . The signal time jitter was estimated as the ratio between the voltage noise and the signal slope at threshold. At -35 {^\circ}C, sensor bias voltage of 200 V and frontend power consumption of 0.9 W/cm^2, the time jitter of the most-probable signal amplitude was estimated to be 21 ps for proton fluence up to 6 x 10 n_eq/cm^2 and 57 ps at 1 x 10^16 n_eq/cm^2 . Increasing the sensor bias to 250 V and the analog voltage of the preamplifier from 1.8 to 2.0 V provides a time jitter of 40 ps at 1 x 10^16 n_eq/cm^2.
△ Less
Submitted 30 October, 2023;
originally announced October 2023.
-
Intel Stratix 10 FPGA design for track reconstruction for the ATLAS experiment at the HL-LHC
Authors:
A. Camplani,
S. Dittmeier,
A. Annovi,
K. Axiotis,
R. Beccherle,
N. Biesuz,
R. Brenner,
S. Débieux,
M. Ellert,
P. Francavilla,
P. Giannetti,
K. Kordas,
M. Mårtensson,
P. Mastrandrea,
C. Noulas,
J. Oechsle,
M. Piendibene,
R. Poggi,
A. Schöning,
A. Sfyrla,
C. L. Sotiropoulou,
J. Steentoft,
T. Tsiakiris,
S. Xella,
J. Zinßer
Abstract:
The fast reconstruction of charged particle tracks with high efficiency and track quality is an essential part of the online data selection for the ATLAS experiment at the High-Luminosity LHC. Dedicated custom designed hardware boards and software simulations have been developed to assess the feasibility of a Hardware Tracking Trigger (HTT) system. The Pattern Recognition Mezzanine (PRM), as part…
▽ More
The fast reconstruction of charged particle tracks with high efficiency and track quality is an essential part of the online data selection for the ATLAS experiment at the High-Luminosity LHC. Dedicated custom designed hardware boards and software simulations have been developed to assess the feasibility of a Hardware Tracking Trigger (HTT) system. The Pattern Recognition Mezzanine (PRM), as part of the HTT system, has been designed to recognize track candidates in silicon detectors with Associative Memory ASICs and to select and reconstruct tracks using linearized algorithms implemented in an Intel Stratix 10 MX FPGA. The highly parallelized FPGA design makes extensive use of the integrated High-Bandwidth-Memory. In this paper, the FPGA design for the PRM board is presented. Its functionalities have been verified in both simulations and hardware tests on an Intel Stratix 10 MX development kit.
△ Less
Submitted 16 May, 2023; v1 submitted 27 February, 2023;
originally announced February 2023.
-
20 ps Time Resolution with a Fully-Efficient Monolithic Silicon Pixel Detector without Internal Gain Layer
Authors:
S. Zambito,
M. Milanesio,
T. Moretti,
L. Paolozzi,
M. Munker,
R. Cardella,
T. Kugathasan,
F. Martinelli,
A. Picardi,
M. Elviretti,
H. Rücker,
A. Trusch,
F. Cadoux,
R. Cardarelli,
S. Débieux,
Y. Favre,
C. A. Fenoglio,
D. Ferrere,
S. Gonzalez-Sevilla,
L. Iodice,
R. Kotitsa,
C. Magliocca,
M. Nessi,
A. Pizarro-Medina,
J. Sabater Iglesias
, et al. (3 additional authors not shown)
Abstract:
A second monolithic silicon pixel prototype was produced for the MONOLITH project. The ASIC contains a matrix of hexagonal pixels with 100 μm pitch, readout by a low-noise and very fast SiGe HBT frontend electronics. Wafers with 50 μm thick epilayer of 350 Ωcm resistivity were used to produce a fully depleted sensor. Laboratory and testbeam measurements of the analog channels present in the pixel…
▽ More
A second monolithic silicon pixel prototype was produced for the MONOLITH project. The ASIC contains a matrix of hexagonal pixels with 100 μm pitch, readout by a low-noise and very fast SiGe HBT frontend electronics. Wafers with 50 μm thick epilayer of 350 Ωcm resistivity were used to produce a fully depleted sensor. Laboratory and testbeam measurements of the analog channels present in the pixel matrix show that the sensor has a 130 V wide bias-voltage operation plateau at which the efficiency is 99.8%. Although this prototype does not include an internal gain layer, the design optimised for timing of the sensor and the front-end electronics provides a time resolutions of 20 ps.
△ Less
Submitted 28 January, 2023;
originally announced January 2023.
-
Testbeam Results of the Picosecond Avalanche Detector Proof-Of-Concept Prototype
Authors:
G. Iacobucci,
S. Zambito,
M. Milanesio,
T. Moretti,
J. Saidi,
L. Paolozzi,
M. Munker,
R. Cardella,
F. Martinelli,
A. Picardi,
H. Rücker,
A. Trusch,
P. Valerio,
F. Cadoux,
R. Cardarelli,
S. Débieux,
Y. Favre,
C. A. Fenoglio,
D. Ferrere,
S. Gonzalez-Sevilla,
Y. Gurimskaya,
R. Kotitsa,
C. Magliocca,
M. Nessi,
A. Pizarro-Medina
, et al. (2 additional authors not shown)
Abstract:
The proof-of-concept prototype of the Picosecond Avalanche Detector, a multi-PN junction monolithic silicon detector with continuous gain layer deep in the sensor depleted region, was tested with a beam of 180 GeV pions at the CERN SPS. The prototype features low noise and fast SiGe BiCMOS frontend electronics and hexagonal pixels with 100 μm pitch. At a sensor bias voltage of 125 V, the detector…
▽ More
The proof-of-concept prototype of the Picosecond Avalanche Detector, a multi-PN junction monolithic silicon detector with continuous gain layer deep in the sensor depleted region, was tested with a beam of 180 GeV pions at the CERN SPS. The prototype features low noise and fast SiGe BiCMOS frontend electronics and hexagonal pixels with 100 μm pitch. At a sensor bias voltage of 125 V, the detector provides full efficiency and average time resolution of 30, 25 and 17 ps in the overall pixel area for a power consumption of 0.4, 0.9 and 2.7 W/cm^2, respectively. In this first prototype the time resolution depends significantly on the distance from the center of the pixel, varying at the highest power consumption measured between 13 ps at the center of the pixel and 25 ps in the inter-pixel region.
△ Less
Submitted 23 August, 2022;
originally announced August 2022.
-
The FASER Detector
Authors:
FASER Collaboration,
Henso Abreu,
Elham Amin Mansour,
Claire Antel,
Akitaka Ariga,
Tomoko Ariga,
Florian Bernlochner,
Tobias Boeckh,
Jamie Boyd,
Lydia Brenner,
Franck Cadoux,
David W. Casper,
Charlotte Cavanagh,
Xin Chen,
Andrea Coccaro,
Olivier Crespo-Lopez,
Stephane Debieux,
Monica D'Onofrio,
Liam Dougherty,
Candan Dozen,
Abdallah Ezzat,
Yannick Favre,
Deion Fellers,
Jonathan L. Feng,
Didier Ferrere
, et al. (72 additional authors not shown)
Abstract:
FASER, the ForwArd Search ExpeRiment, is an experiment dedicated to searching for light, extremely weakly-interacting particles at CERN's Large Hadron Collider (LHC). Such particles may be produced in the very forward direction of the LHC's high-energy collisions and then decay to visible particles inside the FASER detector, which is placed 480 m downstream of the ATLAS interaction point, aligned…
▽ More
FASER, the ForwArd Search ExpeRiment, is an experiment dedicated to searching for light, extremely weakly-interacting particles at CERN's Large Hadron Collider (LHC). Such particles may be produced in the very forward direction of the LHC's high-energy collisions and then decay to visible particles inside the FASER detector, which is placed 480 m downstream of the ATLAS interaction point, aligned with the beam collisions axis. FASER also includes a sub-detector, FASER$ν$, designed to detect neutrinos produced in the LHC collisions and to study their properties. In this paper, each component of the FASER detector is described in detail, as well as the installation of the experiment system and its commissioning using cosmic-rays collected in September 2021 and during the LHC pilot beam test carried out in October 2021. FASER will start taking LHC collision data in 2022, and will run throughout LHC Run 3.
△ Less
Submitted 23 July, 2022;
originally announced July 2022.
-
Picosecond Avalanche Detector -- working principle and gain measurement with a proof-of-concept prototype
Authors:
L. Paolozzi,
M. Munker,
R. Cardella,
M. Milanesio,
Y. Gurimskaya,
F. Martinelli,
A. Picardi,
H. Rücker,
A. Trusch,
P. Valerio,
F. Cadoux,
R. Cardarelli,
S. Débieux,
Y. Favre,
C. A. Fenoglio,
D. Ferrere,
S. Gonzalez-Sevilla,
R. Kotitsa,
C. Magliocca,
T. Moretti,
M. Nessi,
A. Pizarro Medina,
J. Sabater Iglesias,
J. Saidi,
M. Vicente Barreto Pinto
, et al. (2 additional authors not shown)
Abstract:
The Picosecond Avalanche Detector is a multi-junction silicon pixel detector based on a $\mathrm{(NP)_{drift}(NP)_{gain}}$ structure, devised to enable charged-particle tracking with high spatial resolution and picosecond time-stamp capability. It uses a continuous junction deep inside the sensor volume to amplify the primary charge produced by ionizing radiation in a thin absorption layer. The si…
▽ More
The Picosecond Avalanche Detector is a multi-junction silicon pixel detector based on a $\mathrm{(NP)_{drift}(NP)_{gain}}$ structure, devised to enable charged-particle tracking with high spatial resolution and picosecond time-stamp capability. It uses a continuous junction deep inside the sensor volume to amplify the primary charge produced by ionizing radiation in a thin absorption layer. The signal is then induced by the secondary charges moving inside a thicker drift region. A proof-of-concept monolithic prototype, consisting of a matrix of hexagonal pixels with 100 $μ$m pitch, has been produced using the 130 nm SiGe BiCMOS process by IHP microelectronics. Measurements on probe station and with a $^{55}$Fe X-ray source show that the prototype is functional and displays avalanche gain up to a maximum electron gain of 23. A study of the avalanche characteristics, corroborated by TCAD simulations, indicates that space-charge effects due to the large primary charge produced by the conversion of X-rays from the $^{55}$Fe source limits the effective gain.
△ Less
Submitted 25 September, 2022; v1 submitted 16 June, 2022;
originally announced June 2022.
-
Efficiency and time resolution of monolithic silicon pixel detectors in SiGe BiCMOS technology
Authors:
G. Iacobucci,
L. Paolozzi,
P. Valerio,
T. Moretti,
F. Cadoux,
R. Cardarelli,
R. Cardella,
S. Débieux,
Y. Favre,
D. Ferrere,
S. Gonzalez-Sevilla,
Y. Gurimskaya,
R. Kotitsa,
C. Magliocca,
F. Martinelli,
M. Milanesio,
M. Münker,
M. Nessi,
A. Picardi,
J. Saidi,
H. Rücker,
M. Vicente Barreto Pinto,
S. Zambito
Abstract:
A monolithic silicon pixel detector prototype has been produced in the SiGe BiCMOS SG13G2 130 nm node technology by IHP. The ASIC contains a matrix of hexagonal pixels with pitch of approximately 100 $μ$m. Three analog pixels were calibrated in laboratory with radioactive sources and tested in a 180 GeV/c pion beamline at the CERN SPS. A detection efficiency of $\left(99.9^{+0.1}_{-0.2}\right)$% w…
▽ More
A monolithic silicon pixel detector prototype has been produced in the SiGe BiCMOS SG13G2 130 nm node technology by IHP. The ASIC contains a matrix of hexagonal pixels with pitch of approximately 100 $μ$m. Three analog pixels were calibrated in laboratory with radioactive sources and tested in a 180 GeV/c pion beamline at the CERN SPS. A detection efficiency of $\left(99.9^{+0.1}_{-0.2}\right)$% was measured together with a time resolution of $(36.4 \pm 0.8)$ps at the highest preamplifier bias current working point of 150 $μ$A and at a sensor bias voltage of 160 V. The ASIC was also characterized at lower bias voltage and preamplifier current.
△ Less
Submitted 21 January, 2022; v1 submitted 16 December, 2021;
originally announced December 2021.
-
The trigger and data acquisition system of the FASER experiment
Authors:
FASER Collaboration,
Henso Abreu,
Elham Amin Mansour,
Claire Antel,
Akitaka Ariga,
Tomoko Ariga,
Florian Bernlochner,
Tobias Boeckh,
Jamie Boyd,
Lydia Brenner,
Franck Cadoux,
David Casper,
Charlotte Cavanagh,
Xin Chen,
Andrea Coccaro,
Stephane Debieux,
Sergey Dmitrievsky,
Monica D'Onofrio,
Candan Dozen,
Yannick Favre,
Deion Fellers,
Jonathan L. Feng,
Didier Ferrere,
Enrico Gamberini,
Edward Karl Galantay
, et al. (59 additional authors not shown)
Abstract:
The FASER experiment is a new small and inexpensive experiment that is placed 480 meters downstream of the ATLAS experiment at the CERN LHC. FASER is designed to capture decays of new long-lived particles, produced outside of the ATLAS detector acceptance. These rare particles can decay in the FASER detector together with about 500-1000 Hz of other particles originating from the ATLAS interaction…
▽ More
The FASER experiment is a new small and inexpensive experiment that is placed 480 meters downstream of the ATLAS experiment at the CERN LHC. FASER is designed to capture decays of new long-lived particles, produced outside of the ATLAS detector acceptance. These rare particles can decay in the FASER detector together with about 500-1000 Hz of other particles originating from the ATLAS interaction point. A very high efficiency trigger and data acquisition system is required to ensure that the physics events of interest will be recorded. This paper describes the trigger and data acquisition system of the FASER experiment and presents performance results of the system acquired during initial commissioning.
△ Less
Submitted 10 January, 2022; v1 submitted 28 October, 2021;
originally announced October 2021.
-
Time resolution and power consumption of a monolithic silicon pixel prototype in SiGe BiCMOS technology
Authors:
L. Paolozzi,
R. Cardarelli,
S. Débieux,
Y. Favre,
D. Ferrère,
S. Gonzalez-Sevilla,
G. Iacobucci,
M. Kaynak,
F. Martinelli,
M. Nessi,
H. Rücker,
I. Sanna,
DMS Sultan,
P. Valerio,
E. Zaffaroni
Abstract:
SiGe BiCMOS technology can be used to produce ultra-fast, low-power silicon pixel sensors that provide state-of-the-art time resolution even without an internal gain mechanism. The development of such sensors requires the identification of the main factors that may degrade the timing performance and the characterisation of the dependance of the sensor time resolution on the amplifier power consump…
▽ More
SiGe BiCMOS technology can be used to produce ultra-fast, low-power silicon pixel sensors that provide state-of-the-art time resolution even without an internal gain mechanism. The development of such sensors requires the identification of the main factors that may degrade the timing performance and the characterisation of the dependance of the sensor time resolution on the amplifier power consumption. Measurements with a $ \mathrm{^{90}Sr} $ source of a prototype sensor produced in SG13G2 technology from IHP Microelectronics, shows a time resolution of 140 ps at an amplifier current of 7 $ \mathrmμ $A and 45 ps at higher power consumption. A full simulation shows that the resolution on the measurement of the signal time-over-threshold, used to correct for time walk, is the main factor affecting the timing performance.
△ Less
Submitted 28 August, 2020; v1 submitted 28 May, 2020;
originally announced May 2020.
-
A 50 ps resolution monolithic active pixel sensor without internal gain in SiGe BiCMOS technology
Authors:
G. Iacobucci,
R. Cardarelli,
S. Débieux,
F. A. Di Bello,
Y. Favre,
D. Hayakawa,
M. Kaynak,
M. Nessi,
L. Paolozzi,
H. Rücker,
DMS Sultan,
P. Valerio
Abstract:
A monolithic pixelated silicon detector designed for high time resolution has been produced in the SG13G2 130 nm SiGe BiCMOS technology of IHP Mikroelektronik. This proof-of-concept chip contains hexagonal pixels of 65 μm and 130 μm side. The SiGe front-end electronics implemented provides an equivalent noise charge of 90 and 160 electrons for a pixel capacitance of 70 and 220 fF, respectively, an…
▽ More
A monolithic pixelated silicon detector designed for high time resolution has been produced in the SG13G2 130 nm SiGe BiCMOS technology of IHP Mikroelektronik. This proof-of-concept chip contains hexagonal pixels of 65 μm and 130 μm side. The SiGe front-end electronics implemented provides an equivalent noise charge of 90 and 160 electrons for a pixel capacitance of 70 and 220 fF, respectively, and a total time walk of less than 1 ns. Lab measurements with a 90Sr source show a time resolution of the order of 50 ps. This result is competitive with silicon technologies that integrate an avalanche gain mechanism.
△ Less
Submitted 26 August, 2019;
originally announced August 2019.
-
Characterization of the demonstrator of the fast silicon monolithic ASIC for the TT-PET project
Authors:
Lorenzo Paolozzi,
Yves Bandi,
Roberto Cardarelli,
Stephane Debieux,
Yannick Favre,
Didier Ferrere,
Dean Forshaw,
Daiki Hayakawa,
Giuseppe Iacobucci,
Mehmet Kaynak,
Antonio Miucci,
Marzio Nessi,
Emanuele Ripiccini,
Holger Ruecker,
Pierpaolo Valerio,
Michele Weber
Abstract:
The TT-PET collaboration is develo** a small animal TOF-PET scanner based on monolithic silicon pixel sensors in SiGe BiCMOS technology. The demonstrator chip, a small-scale version of the final detector ASIC, consists of a 3 x 10 pixel matrix integrated with the front-end, a 50 ps binning TDC and read out logic. The chip, thinned down to 100 μm and backside metallized, was operated at a voltage…
▽ More
The TT-PET collaboration is develo** a small animal TOF-PET scanner based on monolithic silicon pixel sensors in SiGe BiCMOS technology. The demonstrator chip, a small-scale version of the final detector ASIC, consists of a 3 x 10 pixel matrix integrated with the front-end, a 50 ps binning TDC and read out logic. The chip, thinned down to 100 μm and backside metallized, was operated at a voltage of 180 V. The tests on a beam line of minimum ionizing particles show a detection efficiency greater than 99.9 % and a time resolution down to 110 ps.
△ Less
Submitted 27 November, 2018;
originally announced November 2018.
-
Production and Integration of the ATLAS Insertable B-Layer
Authors:
B. Abbott,
J. Albert,
F. Alberti,
M. Alex,
G. Alimonti,
S. Alkire,
P. Allport,
S. Altenheiner,
L. Ancu,
E. Anderssen,
A. Andreani,
A. Andreazza,
B. Axen,
J. Arguin,
M. Backhaus,
G. Balbi,
J. Ballansat,
M. Barbero,
G. Barbier,
A. Bassalat,
R. Bates,
P. Baudin,
M. Battaglia,
T. Beau,
R. Beccherle
, et al. (352 additional authors not shown)
Abstract:
During the shutdown of the CERN Large Hadron Collider in 2013-2014, an additional pixel layer was installed between the existing Pixel detector of the ATLAS experiment and a new, smaller radius beam pipe. The motivation for this new pixel layer, the Insertable B-Layer (IBL), was to maintain or improve the robustness and performance of the ATLAS tracking system, given the higher instantaneous and i…
▽ More
During the shutdown of the CERN Large Hadron Collider in 2013-2014, an additional pixel layer was installed between the existing Pixel detector of the ATLAS experiment and a new, smaller radius beam pipe. The motivation for this new pixel layer, the Insertable B-Layer (IBL), was to maintain or improve the robustness and performance of the ATLAS tracking system, given the higher instantaneous and integrated luminosities realised following the shutdown. Because of the extreme radiation and collision rate environment, several new radiation-tolerant sensor and electronic technologies were utilised for this layer. This paper reports on the IBL construction and integration prior to its operation in the ATLAS detector.
△ Less
Submitted 6 June, 2018; v1 submitted 2 March, 2018;
originally announced March 2018.
-
Test beam measurement of the first prototype of the fast silicon pixel monolithic detector for the TT-PET project
Authors:
L. Paolozzi,
Y. Bandi,
M. Benoit,
R. Cardarelli,
S. Débieux,
D. Forshaw,
D. Hayakawa,
G. Iacobucci,
M. Kaynak,
A. Miucci,
M. Nessi,
O. Ratib,
E. Ripiccini,
H. Rücker,
P. Valerio,
M. Weber
Abstract:
The TT-PET collaboration is develo** a PET scanner for small animals with 30 ps time-of-flight resolution and sub-millimetre 3D detection granularity. The sensitive element of the scanner is a monolithic silicon pixel detector based on state-of-the-art SiGe BiCMOS technology. The first ASIC prototype for the TT-PET was produced and tested in the laboratory and with minimum ionizing particles. Th…
▽ More
The TT-PET collaboration is develo** a PET scanner for small animals with 30 ps time-of-flight resolution and sub-millimetre 3D detection granularity. The sensitive element of the scanner is a monolithic silicon pixel detector based on state-of-the-art SiGe BiCMOS technology. The first ASIC prototype for the TT-PET was produced and tested in the laboratory and with minimum ionizing particles. The electronics exhibit an equivalent noise charge below 600 e- RMS and a pulse rise time of less than 2 ns, in accordance with the simulations. The pixels with a capacitance of 0.8 pF were measured to have a detection efficiency greater than 99% and, although in the absence of the post-processing, a time resolution of approximately 200 ps.
△ Less
Submitted 6 February, 2018; v1 submitted 5 February, 2018;
originally announced February 2018.
-
The design and construction of the MICE Electron-Muon Ranger
Authors:
R. Asfandiyarov,
P. Bene,
A. Blondel,
D. Bolognini,
F. Cadoux,
S. Debieux,
F. Drielsma,
G. Giannini,
J. S. Graulich,
C. Husi,
Y. Karadzhov,
D. Lietti,
F. Masciocchi,
L. Nicola,
E. Noah Messomo,
M. Prest,
K. Rothenfusser,
R. Sandstrom,
E. Vallazza,
V. Verguilov,
H. Wisting
Abstract:
The Electron-Muon Ranger (EMR) is a fully-active tracking-calorimeter installed in the beam line of the Muon Ionization Cooling Experiment (MICE). The experiment will demonstrate ionization cooling, an essential technology needed for the realization of a Neutrino Factory and/or a Muon Collider. The EMR is designed to measure the properties of low energy beams composed of muons, electrons and pions…
▽ More
The Electron-Muon Ranger (EMR) is a fully-active tracking-calorimeter installed in the beam line of the Muon Ionization Cooling Experiment (MICE). The experiment will demonstrate ionization cooling, an essential technology needed for the realization of a Neutrino Factory and/or a Muon Collider. The EMR is designed to measure the properties of low energy beams composed of muons, electrons and pions, and perform the identification particle-by-particle. The detector consists of 48 orthogonal layers of 59 triangular scintillator bars. The readout is implemented using FPGA custom made electronics and commercially available modules. This article describes the construction of the detector from its design up to its commissioning with cosmic data.
△ Less
Submitted 18 July, 2016;
originally announced July 2016.
-
Measurements of $π^{\pm}$ differential yields from the surface of the T2K replica target for incoming 31 GeV/c protons with the NA61/SHINE spectrometer at the CERN SPS
Authors:
NA61/SHINE Collaboration,
:,
N. Abgrall,
A. Aduszkiewicz,
M. Ajaz,
Y. Ali,
E. Andronov,
T. Antićić,
N. Antoniou,
B. Baatar,
F. Bay,
A. Blondel,
J. Blümer,
M. Bogomilov,
A. Brandin,
A. Bravar,
J. Brzychczyk,
S. A. Bunyatov,
O. Busygina,
P. Christakoglou,
M. Ćirković,
T. Czopowicz,
N. Davis,
S. Debieux,
H. Dembinski
, et al. (135 additional authors not shown)
Abstract:
Measurements of particle emission from a replica of the T2K 90 cm-long carbon target were performed in the NA61/SHINE experiment at CERN SPS, using data collected during a high-statistics run in 2009. An efficient use of the long-target measurements for neutrino flux predictions in T2K requires dedicated reconstruction and analysis techniques. Fully-corrected differential yields of $π^\pm$-mesons…
▽ More
Measurements of particle emission from a replica of the T2K 90 cm-long carbon target were performed in the NA61/SHINE experiment at CERN SPS, using data collected during a high-statistics run in 2009. An efficient use of the long-target measurements for neutrino flux predictions in T2K requires dedicated reconstruction and analysis techniques. Fully-corrected differential yields of $π^\pm$-mesons from the surface of the T2K replica target for incoming 31 GeV/c protons are presented. A possible strategy to implement these results into the T2K neutrino beam predictions is discussed and the propagation of the uncertainties of these results to the final neutrino flux is performed.
△ Less
Submitted 29 November, 2016; v1 submitted 22 March, 2016;
originally announced March 2016.
-
100ps time resolution with thin silicon pixel detectors and a SiGe HBT amplifier
Authors:
Mathieu Benoit,
Roberto Cardarelli,
Stéphane Débieux,
Yannick Favre,
Giuseppe Iacobucci,
Marzio Nessi,
Lorenzo Paolozzi,
Kenji Shu
Abstract:
A 100um thick silicon detector with 1mm2 pad readout optimized for sub-nanosecond time resolution has been developed and tested. Coupled to a purposely developed amplifier based on SiGe HBT technology, this detector was characterized at the H8 beam line at the CERN SPS. An excellent time resolution of (106+-1)ps for silicon detectors was measured with minimum ionizing particles.
A 100um thick silicon detector with 1mm2 pad readout optimized for sub-nanosecond time resolution has been developed and tested. Coupled to a purposely developed amplifier based on SiGe HBT technology, this detector was characterized at the H8 beam line at the CERN SPS. An excellent time resolution of (106+-1)ps for silicon detectors was measured with minimum ionizing particles.
△ Less
Submitted 13 November, 2015;
originally announced November 2015.
-
Electron-Muon Ranger: performance in the MICE Muon Beam
Authors:
D. Adams,
A. Alekou,
M. Apollonio,
R. Asfandiyarov,
G. Barber,
P. Barclay,
A. de Bari,
R. Bayes,
V. Bayliss,
P. Bene,
R. Bertoni,
V. J. Blackmore,
A. Blondel,
S. Blot,
M. Bogomilov,
M. Bonesini,
C. N. Booth,
D. Bowring,
S. Boyd,
T. W. Bradshaw,
U. Bravar,
A. D. Bross,
F. Cadoux,
M. Capponi,
T. Carlisle
, et al. (129 additional authors not shown)
Abstract:
The Muon Ionization Cooling Experiment (MICE) will perform a detailed study of ionization cooling to evaluate the feasibility of the technique. To carry out this program, MICE requires an efficient particle-identification (PID) system to identify muons. The Electron-Muon Ranger (EMR) is a fully-active tracking-calorimeter that forms part of the PID system and tags muons that traverse the cooling c…
▽ More
The Muon Ionization Cooling Experiment (MICE) will perform a detailed study of ionization cooling to evaluate the feasibility of the technique. To carry out this program, MICE requires an efficient particle-identification (PID) system to identify muons. The Electron-Muon Ranger (EMR) is a fully-active tracking-calorimeter that forms part of the PID system and tags muons that traverse the cooling channel without decaying. The detector is capable of identifying electrons with an efficiency of 98.6%, providing a purity for the MICE beam that exceeds 99.8%. The EMR also proved to be a powerful tool for the reconstruction of muon momenta in the range 100-280 MeV/$c$.
△ Less
Submitted 3 November, 2015; v1 submitted 28 October, 2015;
originally announced October 2015.
-
Measurements of $π^\pm$, $K^\pm$, $K^0_S$, $Λ$ and proton production in proton-carbon interactions at 31 GeV/$c$ with the NA61/SHINE spectrometer at the CERN SPS
Authors:
N. Abgrall,
A. Aduszkiewicz,
Y. Ali,
E. Andronov,
T. Antićić,
N. Antoniou,
B. Baatar,
F. Bay,
A. Blondel,
J. Blümer,
M. Bogomilov,
A. Brandin,
A. Bravar,
J. Brzychczyk,
S. A. Bunyatov,
O. Busygina,
P. Christakoglou,
T. Czopowicz,
A. Damyanova,
N. Davis,
S. Debieux,
H. Dembinski,
M. Deveaux,
F. Diakonos,
S. Di Luise
, et al. (127 additional authors not shown)
Abstract:
Measurements of hadron production in p+C interactions at 31 GeV/c are performed using the NA61/ SHINE spectrometer at the CERN SPS. The analysis is based on the full set of data collected in 2009 using a graphite target with a thickness of 4% of a nuclear interaction length. Inelastic and production cross sections as well as spectra of $π^\pm$, $K^\pm$, p, $K^0_S$ and $Λ$ are measured with high pr…
▽ More
Measurements of hadron production in p+C interactions at 31 GeV/c are performed using the NA61/ SHINE spectrometer at the CERN SPS. The analysis is based on the full set of data collected in 2009 using a graphite target with a thickness of 4% of a nuclear interaction length. Inelastic and production cross sections as well as spectra of $π^\pm$, $K^\pm$, p, $K^0_S$ and $Λ$ are measured with high precision. These measurements are essential for improved calculations of the initial neutrino fluxes in the T2K long-baseline neutrino oscillation experiment in Japan. A comparison of the NA61/SHINE measurements with predictions of several hadroproduction models is presented.
△ Less
Submitted 24 February, 2016; v1 submitted 9 October, 2015;
originally announced October 2015.
-
Multiplicity and transverse momentum fluctuations in inelastic proton-proton interactions at the CERN Super Proton Synchrotron
Authors:
NA61/SHINE Collaboration,
:,
A. Aduszkiewicz,
Y. Ali,
E. Andronov,
T. Anticic,
N. Antoniou,
B. Baatar,
F. Bay,
A. Blondel,
J. Blumer,
M. Bogomilov,
A. Bravar,
J. Brzychczyk,
S. A. Bunyatov,
O. Busygina,
P. Christakoglou,
M. Cirkovic,
T. Czopowicz,
N. Davis,
S. Debieux,
H. Dembinski,
M. Deveaux,
F. Diakonos,
S. Di Luise
, et al. (109 additional authors not shown)
Abstract:
Measurements of multiplicity and transverse momentum fluctuations of charged particles were performed in inelastic p+p interactions at 20, 31, 40, 80 and 158 GeV/c beam momentum. Results for the scaled variance of the multiplicity distribution and for three strongly intensive measures of multiplicity and transverse momentum fluctuations \$Δ[P_{T},N]\$, \$Σ[P_{T},N]\$ and \$Φ_{p_T}\$ are presented.…
▽ More
Measurements of multiplicity and transverse momentum fluctuations of charged particles were performed in inelastic p+p interactions at 20, 31, 40, 80 and 158 GeV/c beam momentum. Results for the scaled variance of the multiplicity distribution and for three strongly intensive measures of multiplicity and transverse momentum fluctuations \$Δ[P_{T},N]\$, \$Σ[P_{T},N]\$ and \$Φ_{p_T}\$ are presented. For the first time the results on fluctuations are fully corrected for experimental biases. The results on multiplicity and transverse momentum fluctuations significantly deviate from expectations for the independent particle production. They also depend on charges of selected hadrons. The string-resonance Monte Carlo models EPOS and UrQMD do not describe the data. The scaled variance of multiplicity fluctuations is significantly higher in inelastic p+p interactions than in central Pb+Pb collisions measured by NA49 at the same energy per nucleon. This is in qualitative disagreement with the predictions of the Wounded Nucleon Model. Within the statistical framework the enhanced multiplicity fluctuations in inelastic p+p interactions can be interpreted as due to event-by-event fluctuations of the fireball energy and/or volume.
△ Less
Submitted 30 August, 2016; v1 submitted 1 October, 2015;
originally announced October 2015.
-
NA61/SHINE facility at the CERN SPS: beams and detector system
Authors:
N. Abgrall,
O. Andreeva,
A. Aduszkiewicz,
Y. Ali,
T. Anticic,
N. Antoniou,
B. Baatar,
F. Bay,
A. Blondel,
J. Blumer,
M. Bogomilov,
M. Bogusz,
A. Bravar,
J. Brzychczyk,
S. A. Bunyatov,
P. Christakoglou,
T. Czopowicz,
N. Davis,
S. Debieux,
H. Dembinski,
F. Diakonos,
S. DiLuise,
W. Dominik,
T. Drozhzhova,
J. Dumarchez
, et al. (123 additional authors not shown)
Abstract:
NA61/SHINE (SPS Heavy Ion and Neutrino Experiment) is a multi-purpose experimental facility to study hadron production in hadron-proton, hadron-nucleus and nucleus-nucleus collisions at the CERN Super Proton Synchrotron. It recorded the first physics data with hadron beams in 2009 and with ion beams (secondary 7Be beams) in 2011.
NA61/SHINE has greatly profited from the long development of the C…
▽ More
NA61/SHINE (SPS Heavy Ion and Neutrino Experiment) is a multi-purpose experimental facility to study hadron production in hadron-proton, hadron-nucleus and nucleus-nucleus collisions at the CERN Super Proton Synchrotron. It recorded the first physics data with hadron beams in 2009 and with ion beams (secondary 7Be beams) in 2011.
NA61/SHINE has greatly profited from the long development of the CERN proton and ion sources and the accelerator chain as well as the H2 beamline of the CERN North Area. The latter has recently been modified to also serve as a fragment separator as needed to produce the Be beams for NA61/SHINE. Numerous components of the NA61/SHINE set-up were inherited from its predecessors, in particular, the last one, the NA49 experiment. Important new detectors and upgrades of the legacy equipment were introduced by the NA61/SHINE Collaboration.
This paper describes the state of the NA61/SHINE facility - the beams and the detector system - before the CERN Long Shutdown I, which started in March 2013.
△ Less
Submitted 19 January, 2014;
originally announced January 2014.
-
Measurement of negatively charged pion spectra in inelastic p+p interactions at $p_{lab}$ = 20, 31, 40, 80 and 158 GeV/c
Authors:
NA61/SHINE Collaboration,
:,
N. Abgrall,
A. Aduszkiewicz,
Y. Ali,
T. Anticic,
N. Antoniou,
B. Baatar,
F. Bay,
A. Blondel,
J. Blumer,
M. Bogomilov,
A. Bravar,
J. Brzychczyk,
S. A. Bunyatov,
O. Busygina,
P. Christakoglou,
T. Czopowicz,
N. Davis,
S. Debieux,
H. Dembinski,
F. Diakonos,
S. Di Luise,
W. Dominik,
T. Drozhzhova
, et al. (115 additional authors not shown)
Abstract:
We present experimental results on inclusive spectra and mean multiplicities of negatively charged pions produced in inelastic p+p interactions at incident projectile momenta of 20, 31, 40, 80 and 158 GeV/c ($\sqrt{s} = $ 6.3, 7.7, 8.8, 12.3 and 17.3 GeV, respectively). The measurements were performed using the large acceptance NA61/SHINE hadron spectrometer at the CERN Super Proton Synchrotron.…
▽ More
We present experimental results on inclusive spectra and mean multiplicities of negatively charged pions produced in inelastic p+p interactions at incident projectile momenta of 20, 31, 40, 80 and 158 GeV/c ($\sqrt{s} = $ 6.3, 7.7, 8.8, 12.3 and 17.3 GeV, respectively). The measurements were performed using the large acceptance NA61/SHINE hadron spectrometer at the CERN Super Proton Synchrotron.
Two-dimensional spectra are determined in terms of rapidity and transverse momentum. Their properties such as the width of rapidity distributions and the inverse slope parameter of transverse mass spectra are extracted and their collision energy dependences are presented. The results on inelastic p+p interactions are compared with the corresponding data on central Pb+Pb collisions measured by the NA49 experiment at the CERN SPS.
The results presented in this paper are part of the NA61/SHINE ion program devoted to the study of the properties of the onset of deconfinement and search for the critical point of strongly interacting matter. They are required for interpretation of results on nucleus-nucleus and proton-nucleus collisions.
△ Less
Submitted 26 February, 2014; v1 submitted 9 October, 2013;
originally announced October 2013.
-
Measurements of Production Properties of K0S mesons and Lambda hyperons in Proton-Carbon Interactions at 31 GeV/c
Authors:
N. Abgrall,
A. Aduszkiewicz,
Y. Ali,
T. Anticic,
N. Antoniou,
J. Argyriades,
B. Baatar,
A. Blondel,
J. Blumer,
M. Bogomilov,
A. Bravar,
W. Brooks,
J. Brzychczyk,
S. A. Bunyatov,
O. Busygina,
P. Christakoglou,
T. Czopowicz,
N. Davis,
S. Debieux,
H. Dembinski,
F. Diakonos,
S. Di Luise,
W. Dominik,
T. Drozhzhova,
J. Dumarchez
, et al. (119 additional authors not shown)
Abstract:
Spectra of K0S mesons and Lambda hyperons were measured in p+C interactions at 31 GeV/c with the large acceptance NA61/SHINE spectrometer at the CERN SPS. The data were collected with an isotropic graphite target with a thickness of 4% of a nuclear interaction length. Interaction cross sections, charged pion spectra, and charged kaon spectra were previously measured using the same data set. Result…
▽ More
Spectra of K0S mesons and Lambda hyperons were measured in p+C interactions at 31 GeV/c with the large acceptance NA61/SHINE spectrometer at the CERN SPS. The data were collected with an isotropic graphite target with a thickness of 4% of a nuclear interaction length. Interaction cross sections, charged pion spectra, and charged kaon spectra were previously measured using the same data set. Results on K0S and Lambda production in p+C interactions serve as reference for the understanding of the enhancement of strangeness production in nucleus-nucleus collisions. Moreover, they provide important input for the improvement of neutrino flux predictions for the T2K long baseline neutrino oscillation experiment in Japan. Inclusive production cross sections for K0S and Lambda are presented as a function of laboratory momentum in intervals of the laboratory polar angle covering the range from 0 up to 240 mrad. The results are compared with predictions of several hadron production models. The K0S mean multiplicity in production processes <n_K0S> and the inclusive cross section for K0S production were measured and amount to 0.127 +- 0.005 (stat) +- 0.022 (sys) and 29.0 +- 1.6 (stat) +- 5.0 (sys) mb, respectively.
△ Less
Submitted 8 September, 2013;
originally announced September 2013.
-
Pion emission from the T2K replica target: method, results and application
Authors:
N. Abgrall,
A. Aduszkiewicz,
T. Anticic,
N. Antoniou,
J. Argyriades,
B. Baatar,
A. Blondel,
J. Blumer,
M. Bogomilov,
A. Bravar,
W. Brooks,
J. Brzychczyk,
A. Bubak,
S. A. Bunyatov,
O. Busygina,
P. Christakoglou,
P. Chung,
T. Czopowicz,
N. Davis,
S. Debieux,
S. Di Luise,
W. Dominik,
J. Dumarchez,
K. Dynowski,
R. Engel
, et al. (128 additional authors not shown)
Abstract:
The T2K long-baseline neutrino oscillation experiment in Japan needs precise predictions of the initial neutrino flux. The highest precision can be reached based on detailed measurements of hadron emission from the same target as used by T2K exposed to a proton beam of the same kinetic energy of 30 GeV. The corresponding data were recorded in 2007-2010 by the NA61/SHINE experiment at the CERN SPS…
▽ More
The T2K long-baseline neutrino oscillation experiment in Japan needs precise predictions of the initial neutrino flux. The highest precision can be reached based on detailed measurements of hadron emission from the same target as used by T2K exposed to a proton beam of the same kinetic energy of 30 GeV. The corresponding data were recorded in 2007-2010 by the NA61/SHINE experiment at the CERN SPS using a replica of the T2K graphite target. In this paper details of the experiment, data taking, data analysis method and results from the 2007 pilot run are presented. Furthermore, the application of the NA61/SHINE measurements to the predictions of the T2K initial neutrino flux is described and discussed.
△ Less
Submitted 28 November, 2012; v1 submitted 9 July, 2012;
originally announced July 2012.