-
Measurement of the neutron decay electron-antineutrino angular correlation by the aCORN experiment
Authors:
M. T. Hassan,
W. A. Byron,
G. Darius,
C. DeAngelis,
F. E. Wietfeldt,
B. Collett,
G. L. Jones,
A. Komives,
G. Noid,
E. J. Stephenson,
F. Bateman,
M. S. Dewey,
T. R. Gentile,
M. P. Mendenhall,
J. S. Nico
Abstract:
The aCORN experiment measures the neutron decay electron-antineutrino correlation ($a$-coefficient) using a novel method based on an asymmetry in proton time-of-flight for events where the beta electron and recoil proton are detected in delayed coincidence. We report the data analysis and result from the second run at the NIST Center for Neutron Research, using the high-flux cold neutron beam on t…
▽ More
The aCORN experiment measures the neutron decay electron-antineutrino correlation ($a$-coefficient) using a novel method based on an asymmetry in proton time-of-flight for events where the beta electron and recoil proton are detected in delayed coincidence. We report the data analysis and result from the second run at the NIST Center for Neutron Research, using the high-flux cold neutron beam on the new NG-C neutron guide end position: $a = -0.10758 \pm 0.00136 (\mbox{stat}) \pm 0.00148 (\mbox{sys})$. This is consistent within uncertainties with the result from the first aCORN run on the NG-6 cold neutron beam. Combining the two aCORN runs we obtain $a = -0.10782 \pm 0.00124 (\mbox{stat}) \pm 0.00133 (\mbox{sys})$, which has an overall relative standard uncertainty of 1.7 \%. The corresponding result for the ratio of weak coupling constants $λ= G_A/G_V$ is $λ= -1.2796\pm 0.0062$.
△ Less
Submitted 28 December, 2020;
originally announced December 2020.
-
Measurement of the electron-antineutrino correlation in neutron beta decay: aCORN experiment
Authors:
F. E. Wietfeldt,
W. A. Byron,
G. Darius,
C. R. DeAngelis,
M. T. Hassan,
M. S. Dewey,
M. P. Mendenhall,
J. S. Nico,
B. Collett,
G. L. Jones,
A. Komives,
E. J. Stephenson
Abstract:
The aCORN experiment uses a novel asymmetry method to measure the electron-antineutrino correlation (a-coefficient) in free neutron decay that does not require precision proton spectroscopy. aCORN completed two physics runs at the NIST Center for Neutron Research. The first run on the NG-6 beam line in 2013--2014 obtained the result a = 0.1090 +/- 0.0030 (stat) +/- 0.0028 (sys), a total uncertaint…
▽ More
The aCORN experiment uses a novel asymmetry method to measure the electron-antineutrino correlation (a-coefficient) in free neutron decay that does not require precision proton spectroscopy. aCORN completed two physics runs at the NIST Center for Neutron Research. The first run on the NG-6 beam line in 2013--2014 obtained the result a = 0.1090 +/- 0.0030 (stat) +/- 0.0028 (sys), a total uncertainty of 3.8%. The second run on the new NG-C high flux beam line promises an improvement in precision to <2%.
△ Less
Submitted 1 October, 2018;
originally announced October 2018.
-
aCORN: an experiment to measure the electron-antineutrino correlation coefficient in free neutron decay
Authors:
B. Collett,
F. Bateman,
W. K. Bauder,
J. Byrne,
W. A. Byron,
W. Chen,
G. Darius,
C. DeAngelis,
M. S. Dewey,
T. R. Gentile,
M. T. Hassan,
G. L. Jones,
A. Komives,
A. Laptev,
M. P. Mendenhall,
J. S. Nico,
G. Noid,
H. Park,
E. J. Stephenson,
I. Stern,
K. J. S. Stockton,
C. Trull,
F. E. Wietfeldt,
B. G. Yerozolimsky
Abstract:
We describe an apparatus used to measure the electron-antineutrino angular correlation coefficient in free neutron decay. The apparatus employs a novel measurement technique in which the angular correlation is converted into a proton time-of-flight asymmetry that is counted directly, avoiding the need for proton spectroscopy. Details of the method, apparatus, detectors, data acquisition, and data…
▽ More
We describe an apparatus used to measure the electron-antineutrino angular correlation coefficient in free neutron decay. The apparatus employs a novel measurement technique in which the angular correlation is converted into a proton time-of-flight asymmetry that is counted directly, avoiding the need for proton spectroscopy. Details of the method, apparatus, detectors, data acquisition, and data reduction scheme are presented, along with a discussion of the important systematic effects.
△ Less
Submitted 21 February, 2017; v1 submitted 17 January, 2017;
originally announced January 2017.
-
The aCORN Backscatter-Suppressed Beta Spectrometer
Authors:
M. T. Hassan,
F. Bateman,
B. Collett,
G. Darius,
C. DeAngelis,
M. S. Dewey,
G. L. Jones,
A. Komives,
A. Laptev,
M. P. Mendenhall,
J. S. Nico,
G. Noid,
E. J. Stephenson,
I. Stern,
C. Trull,
F. E. Wietfeldt
Abstract:
Backscatter of electrons from a beta spectrometer, with incomplete energy deposition, can lead to undesirable effects in many types of experiments. We present and discuss the design and operation of a backscatter-suppressed beta spectrometer that was developed as part of a program to measure the electron-antineutrino correlation coefficient in neutron beta decay (aCORN). An array of backscatter ve…
▽ More
Backscatter of electrons from a beta spectrometer, with incomplete energy deposition, can lead to undesirable effects in many types of experiments. We present and discuss the design and operation of a backscatter-suppressed beta spectrometer that was developed as part of a program to measure the electron-antineutrino correlation coefficient in neutron beta decay (aCORN). An array of backscatter veto detectors surrounds a plastic scintillator beta energy detector. The spectrometer contains an axial magnetic field gradient, so electrons are efficiently admitted but have a low probability for esca** back through the entrance after backscattering. The design, construction, calibration, and performance of the spectrometer are discussed.
△ Less
Submitted 25 January, 2017; v1 submitted 17 January, 2017;
originally announced January 2017.