Ambient neutron dosimetry in high energy and pulsed neutron fields
Authors:
Ariel Tarifeno-Saldivia,
Francisco Calvino,
Alfredo De Blas,
Benedetta Brusasco,
Adria Casanovas-Hoste,
Ana M. Cives,
Guillem Cortes,
Roger Garcia,
Francisco Molina,
Nil Mont-Geli,
Max Pallas,
Cristian Pavez
Abstract:
The status of the LINrem project is presented, focusing on the development of innovative neutron dosimeters with enhanced energy sensitivity, time resolution, and portability. Designed to meet the technical demands of radiation protection in modern particle and nuclear facilities, these dosimeters are discussed in detail. Results from experimental campaigns showcasing their efficacy in pulsed fiel…
▽ More
The status of the LINrem project is presented, focusing on the development of innovative neutron dosimeters with enhanced energy sensitivity, time resolution, and portability. Designed to meet the technical demands of radiation protection in modern particle and nuclear facilities, these dosimeters are discussed in detail. Results from experimental campaigns showcasing their efficacy in pulsed fields generated by fusion plasmas and high-intensity pulsed lasers are presented. Additionally, prospects and future plans for the LINrem project are outlined.
△ Less
Submitted 27 March, 2024;
originally announced March 2024.
-
Commissioning of miniBELEN-10A, a moderated neutron counter with a flat efficiency for thick-target neutron yields measurements
Authors:
N Mont-Geli,
A Tarifeño-Saldivia,
L M Fraile,
S Viñals,
A Perea,
M Pallàs,
G Cortés,
G Garcia,
E Nácher,
J L Tain,
V Alcayne,
O Alonso-Sañudo,
A Algora,
J Balibrea-Correa,
J Benito,
M J G Borge,
J A Briz,
F Calviño,
D Cano-Ott,
A De Blas,
C Domingo-Pardo,
B Fernández,
R Garcia,
J Gómez-Camacho,
E M González-Romero
, et al. (18 additional authors not shown)
Abstract:
miniBELEN-10A is a modular and transportable moderated neutron counter with a nearly flat detection efficiency up to 8 MeV. The detector was designed to carry out measurements of (alpha, n) reactions in the context of the Measurement of Alpha Neutron Yields (MANY) project. In this work we present the results of the commissioning of miniBELEN-10A using the relatively well-known thick-target neutron…
▽ More
miniBELEN-10A is a modular and transportable moderated neutron counter with a nearly flat detection efficiency up to 8 MeV. The detector was designed to carry out measurements of (alpha, n) reactions in the context of the Measurement of Alpha Neutron Yields (MANY) project. In this work we present the results of the commissioning of miniBELEN-10A using the relatively well-known thick-target neutron yields from 27Al(alpha, n)30P.
△ Less
Submitted 14 April, 2023;
originally announced April 2023.
-
miniBELEN: a modular neutron counter for (alpha,n) reactions
Authors:
N Mont-Geli,
A Tarifeño-Saldivia,
L M Fraile,
S Viñals,
A Perea,
M Pallàs,
G Cortés,
E Nácher,
J L Tain,
V Alcayne,
A Algora,
J Balibrea-Correa,
J Benito,
M J G Borge,
J A Briz,
F Calviño,
D Cano-Ott,
A De Blas,
C Domingo-Pardo,
B Fernández,
R Garcia,
G García,
J Gómez-Camacho,
E M González-Romero,
C Guerrero
, et al. (16 additional authors not shown)
Abstract:
miniBELEN is a modular and transportable neutron moderated counter with a nearly flat neutron detection efficiency up to 10 MeV. Modularity implies that the moderator can be reassembled in different ways in order to obtain different types of response. The detector has been developed in the context of the Measurement of Alpha Neutron Yields (MANY) collaboration, which is a scientific effort aiming…
▽ More
miniBELEN is a modular and transportable neutron moderated counter with a nearly flat neutron detection efficiency up to 10 MeV. Modularity implies that the moderator can be reassembled in different ways in order to obtain different types of response. The detector has been developed in the context of the Measurement of Alpha Neutron Yields (MANY) collaboration, which is a scientific effort aiming to carry out measurements of (alpha,n) production yields, reaction cross-sections and neutron energy spectra. In this work we present and discuss several configurations of the miniBELEN detector. The experimental validation of the efficiency calculations using 252Cf sources and the measurement of the 27Al(alpha,n)30P reaction is also presented.
△ Less
Submitted 14 April, 2023;
originally announced April 2023.
-
Long-term evolution of the neutron rate at the Canfranc Underground Laboratory
Authors:
S. E. A. Orrigo,
J. L. Tain,
N. Mont-Geli,
A. Tarifeño-Saldivia,
L. M. Fraile,
M. Grieger,
J. Agramunt,
A. Algora,
D. Bemmerer,
F. Calviño,
G. Cortés,
A. De Blas,
I. Dillmann,
A. Domínguez Bugarín,
R. García,
E. Nacher,
A. Tolosa-Delgado
Abstract:
We report results on the long-term variation of the neutron counting rate at the Canfranc Underground Laboratory, of importance for several low-background experiments installed there, including rare-event searches. The measurement campaign was performed employing the High Efficiency Neutron Spectrometry Array (HENSA) mounted in Hall A and lasted 412 live days. The present study is the first long-t…
▽ More
We report results on the long-term variation of the neutron counting rate at the Canfranc Underground Laboratory, of importance for several low-background experiments installed there, including rare-event searches. The measurement campaign was performed employing the High Efficiency Neutron Spectrometry Array (HENSA) mounted in Hall A and lasted 412 live days. The present study is the first long-term measurement of the neutron rate with sensitivity over a wide range of neutron energies (from thermal up to 0.1 GeV and beyond) performed in any underground laboratory so far. Data on the environmental variables inside the experimental hall (radon concentration, air temperature, air pressure and humidity) were also acquired during all the measurement campaign. We have investigated for the first time the evolution of the neutron rate for different energies of the neutrons and its correlation with the ambient variables.
△ Less
Submitted 29 August, 2022; v1 submitted 29 April, 2022;
originally announced April 2022.
-
First results from the HENSA/ANAIS collaboration at the Canfranc Underground Laboratory
Authors:
N Mont-Geli,
A Tarifeño-Saldivia,
S E A Orrigo,
J L Tain,
M Grieger,
J Agramunt,
A Algora,
J Amaré,
D Bemmerer,
F Calviño,
S Cebrián,
I Coarasa,
G Cortés,
A De Blas,
I Dillmann,
L M Fraile,
E García,
R García,
M Martínez,
E Nacher,
Y Ortigoza,
A Ortiz,
M Pallàs,
J Puimedón,
A Salinas
, et al. (2 additional authors not shown)
Abstract:
The HENSA/ANAIS collaboration aims for the precise determination of the neutron flux that could affect ANAIS-112, an experiment looking for the dark matter annual modulation using NaI(Tl) scintillators. In this work, the first measurements of the neutron flux and Monte Carlo simulations of the neutron spectrum are reported.
The HENSA/ANAIS collaboration aims for the precise determination of the neutron flux that could affect ANAIS-112, an experiment looking for the dark matter annual modulation using NaI(Tl) scintillators. In this work, the first measurements of the neutron flux and Monte Carlo simulations of the neutron spectrum are reported.
△ Less
Submitted 3 February, 2022; v1 submitted 24 November, 2021;
originally announced November 2021.
-
Measurement of the neutron flux at the Canfranc Underground Laboratory with HENSA
Authors:
S. E. A. Orrigo,
J. L. Tain,
N. Mont-Geli,
A. Tarifeño-Saldivia,
L. M. Fraile,
M. Grieger,
J. Agramunt,
A. Algora,
D. Bemmerer,
F. Calviño,
G. Cortés,
A. De Blas,
I. Dillmann,
A. Domínguez Bugarín,
R. García,
E. Nacher,
A. Tolosa
Abstract:
We have performed a long-term measurement of the neutron flux with the High Efficiency Neutron Spectrometry Array HENSA in the Hall A of the Canfranc Underground Laboratory. The Hall A measurement campaign lasted from October 2019 to March 2021, demonstrating an excellent stability of the HENSA setup. Preliminary results on the neutron flux from this campaign are presented for the first time. In P…
▽ More
We have performed a long-term measurement of the neutron flux with the High Efficiency Neutron Spectrometry Array HENSA in the Hall A of the Canfranc Underground Laboratory. The Hall A measurement campaign lasted from October 2019 to March 2021, demonstrating an excellent stability of the HENSA setup. Preliminary results on the neutron flux from this campaign are presented for the first time. In Phase 1 (113 live days) a total neutron flux of 1.66(2) $\times$10$^{-5}$ cm$^{-2}$ s$^{-1}$ is obtained. Our results are in good agreement with those from our previous shorter measurement where a reduced experimental setup was employed.
△ Less
Submitted 17 November, 2021;
originally announced November 2021.