The Phase-I Trigger Readout Electronics Upgrade of the ATLAS Liquid Argon Calorimeters
Authors:
G. Aad,
A. V. Akimov,
K. Al Khoury,
M. Aleksa,
T. Andeen,
C. Anelli,
N. Aranzabal,
C. Armijo,
A. Bagulia,
J. Ban,
T. Barillari,
F. Bellachia,
M. Benoit,
F. Bernon,
A. Berthold,
H. Bervas,
D. Besin,
A. Betti,
Y. Bianga,
M. Biaut,
D. Boline,
J. Boudreau,
T. Bouedo,
N. Braam,
M. Cano Bret
, et al. (173 additional authors not shown)
Abstract:
The Phase-I trigger readout electronics upgrade of the ATLAS Liquid Argon calorimeters enhances the physics reach of the experiment during the upcoming operation at increasing Large Hadron Collider luminosities. The new system, installed during the second Large Hadron Collider Long Shutdown, increases the trigger readout granularity by up to a factor of ten as well as its precision and range. Cons…
▽ More
The Phase-I trigger readout electronics upgrade of the ATLAS Liquid Argon calorimeters enhances the physics reach of the experiment during the upcoming operation at increasing Large Hadron Collider luminosities. The new system, installed during the second Large Hadron Collider Long Shutdown, increases the trigger readout granularity by up to a factor of ten as well as its precision and range. Consequently, the background rejection at trigger level is improved through enhanced filtering algorithms utilizing the additional information for topological discrimination of electromagnetic and hadronic shower shapes. This paper presents the final designs of the new electronic elements, their custom electronic devices, the procedures used to validate their proper functioning, and the performance achieved during the commissioning of this system.
△ Less
Submitted 16 May, 2022; v1 submitted 15 February, 2022;
originally announced February 2022.
Calibration and performance of the LHCb calorimeters in Run 1 and 2 at the LHC
Authors:
C. Abellán Beteta,
A. Alfonso Albero,
Y. Amhis,
S. Barsuk,
C. Beigbeder-Beau,
I. Belyaev,
R. Bonnefoy,
D. Breton,
O. Callot,
M. Calvo Gomez,
A. Camboni,
H. Chanal,
D. Charlet,
M. Chefdeville,
V. Coco,
E. Cogneras,
A. Comerma-Montells,
S. Coquereau,
O. Deschamps,
F. Domingo Bonal,
C. Drancourt,
O. Duarte,
N. Dumont Dayot,
R. Dzhelyadin,
V. Egorychev
, et al. (62 additional authors not shown)
Abstract:
The calibration and performance of the LHCb Calorimeter system in Run 1 and 2 at the LHC are described. After a brief description of the sub-detectors and of their role in the trigger, the calibration methods used for each part of the system are reviewed. The changes which occurred with the increase of beam energy in Run 2 are explained. The performances of the calorimetry for $γ$ and $π^0$ are de…
▽ More
The calibration and performance of the LHCb Calorimeter system in Run 1 and 2 at the LHC are described. After a brief description of the sub-detectors and of their role in the trigger, the calibration methods used for each part of the system are reviewed. The changes which occurred with the increase of beam energy in Run 2 are explained. The performances of the calorimetry for $γ$ and $π^0$ are detailed. A few results from collisions recorded at $\sqrt {s}$ = 7, 8 and 13 TeV are shown.
△ Less
Submitted 26 August, 2020;
originally announced August 2020.