A 25-micron single photon sensitive kinetic inductance detector
Authors:
Peter K. Day,
Nicholas F. Cothard,
Christopher Albert,
Logan Foote,
Elijah Kane,
Byeong H. Eom,
Ritoban Basu Thakur,
Reinier M. J. Janssen,
Andrew Beyer,
Pierre Echternach,
Sven van Berkel,
Steven Hailey-Dunsheath,
Thomas R. Stevenson,
Shahab Dabironezare,
Jochem J. A. Baselmans,
Jason Glenn,
C. Matt Bradford,
Henry G. Leduc
Abstract:
We report measurements characterizing the performance of a kinetic inductance detector array designed for a wavelength of 25 microns and very low optical background level suitable for applications such as a far-infrared instrument on a cryogenically cooled space telescope. In a pulse counting mode of operation at low optical flux, the detectors can resolve individual 25-micron photons. In an integ…
▽ More
We report measurements characterizing the performance of a kinetic inductance detector array designed for a wavelength of 25 microns and very low optical background level suitable for applications such as a far-infrared instrument on a cryogenically cooled space telescope. In a pulse counting mode of operation at low optical flux, the detectors can resolve individual 25-micron photons. In an integrating mode, the detectors remain photon noise limited over more than six orders of magnitude in absorbed power from 70 zW to 200 fW, with a limiting NEP of 4.6 x 10^-20 W/rtHz at 1 Hz. In addition, the detectors are highly stable with flat power spectra under optical load down to 1 mHz. Operational parameters of the detector are determined including the efficiency of conversion of the incident optical power into quasiparticles in the aluminum absorbing element and the quasiparticle self-recombination constant.
△ Less
Submitted 14 May, 2024; v1 submitted 15 April, 2024;
originally announced April 2024.
-
Significant noise improvement in a Kinetic Inductance Phonon-Mediated detector by use of a wideband parametric amplifier
Authors:
Karthik Ramanathan,
Osmond Wen,
Taylor Aralis,
Ritoban Basu Thakur,
Bruce Bumble,
Yen-Yung Chang,
Peter K. Day,
Byeong Ho Eom,
Henry G. LeDuc,
Brandon J. Sandoval,
Ryan Stephenson,
Sunil R. Golwala
Abstract:
Microwave Kinetic Inductance Detectors (MKIDs) have been demonstrated as capable phonon sensors when coupled to crystalline substrates, and have been proposed as detectors for next-generation rare-event searches such as for the direct detection of dark matter. These Kinetic Inductance Phonon Mediated (KIPM) detector designs, favoring large superconducting absorber volumes and high readout powers,…
▽ More
Microwave Kinetic Inductance Detectors (MKIDs) have been demonstrated as capable phonon sensors when coupled to crystalline substrates, and have been proposed as detectors for next-generation rare-event searches such as for the direct detection of dark matter. These Kinetic Inductance Phonon Mediated (KIPM) detector designs, favoring large superconducting absorber volumes and high readout powers, are oftentimes limited in their sensitivity by low temperature amplifier noise introduced in the signal readout chain. We report here an effort to couple a wideband Kinetic Inductance Travelling Wave Parametric Amplifier (KI-TWPA), operated near the Standard Quantum Limit of minimal added amplifier noise, to sensors spanning a 70 MHz bandwidth at 3.5 GHz. This results in a ~5x improvement in the inferred detector energy resolution in the best sensor and highlights the potential of constructing O(100) meV resolving phonon-mediated particle detectors. We detail limitations introduced by lossy passive components, degraded RF responsivity, and microphysical noise sources like two-level systems (TLS), in achieving ultimate quantum-limited system noise levels.
△ Less
Submitted 8 February, 2024;
originally announced February 2024.
-
Hierarchical phased-array antennas coupled to Al KIDs: a scalable architecture for multi-band mm/submm focal planes
Authors:
Jean-Marc Martin,
Junhan Kim,
Fabien Defrance,
Shibo Shu,
Andrew D. Beyer,
Peter K. Day,
Jack Sayers,
Sunil R. Golwala
Abstract:
We present the optical characterization of two-scale hierarchical phased-array antenna kinetic inductance detectors (KIDs) for millimeter/submillimeter wavelengths. Our KIDs have a lumped-element architecture with parallel plate capacitors and aluminum inductors. The incoming light is received with a hierarchical phased array of slot-dipole antennas, split into 4 frequency bands (between 125 GHz a…
▽ More
We present the optical characterization of two-scale hierarchical phased-array antenna kinetic inductance detectors (KIDs) for millimeter/submillimeter wavelengths. Our KIDs have a lumped-element architecture with parallel plate capacitors and aluminum inductors. The incoming light is received with a hierarchical phased array of slot-dipole antennas, split into 4 frequency bands (between 125 GHz and 365 GHz) with on-chip lumped-element band-pass filters, and routed to different KIDs using microstriplines. Individual pixels detect light for the 3 higher frequency bands (190-365 GHz) and the signals from four individual pixels are coherently summed to create a larger pixel detecting light for the lowest-frequency band (125-175 GHz). The spectral response of the band-pass filters was measured using Fourier transform spectroscopy (FTS), the far-field beam pattern of the phased-array antennas was obtained using an infrared source mounted on a 2-axis translating stage, and the optical efficiency of the KIDs was characterized by observing loads at 294 K and 77 K. We report on the results of these three measurements.
△ Less
Submitted 30 January, 2024;
originally announced January 2024.
-
Frequency-domain multiplexing of SNSPDs with tunable superconducting resonators
Authors:
Sasha Sypkens,
Lorenzo Minutolo,
Sahil Patel,
Emanuel Knehr,
Alexander B. Walter,
Henry G. Leduc,
Lautaro Narváez,
Ralph Chamberlin,
Tracee Jamison-Hooks,
Matthew D. Shaw,
Peter K. Day,
Boris Korzh
Abstract:
This work culminates in a demonstration of an alternative Frequency Domain Multiplexing (FDM) scheme for Superconducting Nanowire Single-Photon Detectors (SNSPDs) using the Kinetic inductance Parametric UP-converter (KPUP) made out of NbTiN. There are multiple multiplexing architectures for SNSPDs that are already in use, but FDM could prove superior in applications where the operational bias curr…
▽ More
This work culminates in a demonstration of an alternative Frequency Domain Multiplexing (FDM) scheme for Superconducting Nanowire Single-Photon Detectors (SNSPDs) using the Kinetic inductance Parametric UP-converter (KPUP) made out of NbTiN. There are multiple multiplexing architectures for SNSPDs that are already in use, but FDM could prove superior in applications where the operational bias currents are very low, especially for mid- and far-infrared SNSPDs. Previous FDM schemes integrated the SNSPD within the resonator, while in this work we use an external resonator, which gives more flexibility to optimize the SNSPD architecture. The KPUP is a DC-biased superconducting resonator in which a nanowire is used as its inductive element to enable sensitivity to current perturbations. When coupled to an SNSPD, the KPUP can be used to read out current pulses on the few $μ$A scale. The KPUP is made out of NbTiN, which has high non-linear kinetic inductance for increased sensitivity at higher current bias and high operating temperature. Meanwhile, the SNSPD is made from WSi, which is a popular material for broadband SNSPDs. To read out the KPUP and SNSPD array, a software-defined radio platform and a graphics processing unit are used. Frequency Domain Multiplexed SNSPDs have applications in astronomy, remote sensing, exoplanet science, dark matter detection, and quantum sensing.
△ Less
Submitted 30 January, 2024;
originally announced January 2024.
-
Parallel-Plate Capacitor Titanium Nitride Kinetic Inductance Detectors for Infrared Astronomy
Authors:
Joanna Perido,
Peter K. Day,
Andrew D. Beyer,
Nicholas F. Cothard,
Steven Hailey-Dunsheath,
Henry G. Leduc,
Byeong H. Eom,
Jason Glenn
Abstract:
The Balloon Experiment for Galactic INfrared Science (BEGINS) is a concept for a sub-orbital observatory that will operate from $λ$ = 25-250 $μ$m to characterize dust in the vicinity of high-mass stars. The mission's sensitivity requirements will be met by utilizing arrays of 1,840 lens-coupled, lumped-element kinetic inductance detectors (KIDs) operating at 300 mK. Each KID will consist of a tita…
▽ More
The Balloon Experiment for Galactic INfrared Science (BEGINS) is a concept for a sub-orbital observatory that will operate from $λ$ = 25-250 $μ$m to characterize dust in the vicinity of high-mass stars. The mission's sensitivity requirements will be met by utilizing arrays of 1,840 lens-coupled, lumped-element kinetic inductance detectors (KIDs) operating at 300 mK. Each KID will consist of a titanium nitride (TiN) parallel strip absorbing inductive section and parallel plate capacitor (PPC) deposited on a silicon (Si) substrate. The PPC geometry allows for reduction of the pixel spacing. At the BEGINS focal plane the detectors require optical NEPs from $2\times10^{-16}$ W/$\sqrt{\textrm{Hz}}$ to $6\times10^{-17}$ W/$\sqrt{\textrm{Hz}}$ from 25-250 $μ$m for optical loads ranging from 4 pW to 10 pW. We present the design, optical performance and quasiparticle lifetime measurements of a prototype BEGINS KID array at 25 $μ$m when coupled to Fresnel zone plate lenses. For our optical set up and the absorption efficiency of the KIDs, the electrical NEP requirement at 25 $μ$m is $7.6\times10^{-17}$ W/$\sqrt{\textrm{Hz}}$ for an absorbed optical power of 0.36 pW. We find that over an average of five resonators the the detectors are photon noise limited down to about 200 fW, with a limiting NEP of about $7.4\times10^{-17}$ W/$\sqrt{\textrm{Hz}}$.
△ Less
Submitted 28 December, 2023;
originally announced December 2023.
-
Cross-Slot Metal-Mesh Bandpass Filters for Far-Infrared Astronomy
Authors:
Joanna Perido,
Kevin Denis,
Jason Glenn,
Nicholas F. Cothard,
Manuel Quijada,
Jessica Patel,
Edward Wollack,
Tilak Hewagama,
Shahid Aslam,
Peter K. Day
Abstract:
The far-infrared (IR) region is rich with information needed to characterize interstellar dust and to investigate the cold outer planets of the solar system and their icy moons. The proposed sub-orbital observatory the Balloon Experiment for Galactic INfrared Science (BEGINS) will utilize cryogenic instruments to map spectral energy distributions (SEDs) of interstellar dust in the Cygnus molecular…
▽ More
The far-infrared (IR) region is rich with information needed to characterize interstellar dust and to investigate the cold outer planets of the solar system and their icy moons. The proposed sub-orbital observatory the Balloon Experiment for Galactic INfrared Science (BEGINS) will utilize cryogenic instruments to map spectral energy distributions (SEDs) of interstellar dust in the Cygnus molecular cloud complex. A future high priority flagship mission Uranus Orbiter and Probe carrying a net flux radiometer (NFR) will study the in situ heat flux of the icy giants atmosphere to 10 bar pressure. These instruments require far-IR filters to define the instrument spectral bandwidths. Our ultimate goal is to define the instrument bands of BEGINS and the NFR with linear-variable filters (LVFs) and discrete-variable filters (DVFs). The LVFs and DVFs will be made of metal mesh band-pass filters (MMBF) comprised of a 100 nm thick gold film with cross-shaped slots of varying sizes along a silicon (Si) substrate with cyclic olefin copolymer (COC) anti-reflection (AR) coatings. We present our progress towards LVFs and DVFs with simulated and measured transmission of a room temperature, non-AR coated, single-band 44 $μ$m MMBF filter. We have successfully fabricated, measured, and modeled a non-AR coated, room temperature 44 $μ$m MMBF. The transmission at room temperature and non-AR coated was measured to be 27\% with a resolving power of 11. When COC-AR coated on both sides the transmission is expected to increase to 69\% with a resolving power of 10.
△ Less
Submitted 22 December, 2023;
originally announced December 2023.
-
Characterization of a Far-Infrared Kinetic Inductance Detector Prototype for PRIMA
Authors:
Steven Hailey-Dunsheath,
Sven van Berkel,
Andrew E. Beyer,
Logan Foote,
Reinier M. J. Janssen,
Henry G. LeDuc,
Pierre M. Echternach,
Charles M. Bradford,
Jochem J. A. Baselmans,
Shahab Dabironezare,
Peter K. Day,
Nicholas F. Cothard,
Jason Glenn
Abstract:
The PRobe far-Infrared Mission for Astrophysics (PRIMA) is under study as a potential far-IR space mission, featuring actively cooled optics, and both imaging and spectroscopic instrumentation. To fully take advantage of the low background afforded by a cold telescope, spectroscopy with PRIMA requires detectors with a noise equivalent power (NEP) better than $1 \times 10^{-19}$ W Hz$^{-1/2}$. To m…
▽ More
The PRobe far-Infrared Mission for Astrophysics (PRIMA) is under study as a potential far-IR space mission, featuring actively cooled optics, and both imaging and spectroscopic instrumentation. To fully take advantage of the low background afforded by a cold telescope, spectroscopy with PRIMA requires detectors with a noise equivalent power (NEP) better than $1 \times 10^{-19}$ W Hz$^{-1/2}$. To meet this goal we are develo** large format arrays of kinetic inductance detectors (KIDs) to work across the $25-250$ micron range. Here we present the design and characterization of a single pixel prototype detector optimized for $210$ micron. The KID consists of a lens-coupled aluminum inductor-absorber connected to a niobium interdigitated capacitor to form a 2 GHz resonator. We have fabricated a small array with 28 KIDs, and we measure the performance of one of these detectors with an optical loading in the $0.01 - 300$ aW range. At low loading the detector achieves an NEP of $9\times10^{-20}$ W Hz$^{-1/2}$ at a 10 Hz readout frequency, and the lens-absorber system achieves a good optical efficiency. An extrapolation of these measurements suggest this detector may remain photon noise limited at up to 20 fW of loading, offering a high dynamic range for PRIMA observations of bright astronomical sources.
△ Less
Submitted 17 April, 2024; v1 submitted 6 November, 2023;
originally announced November 2023.
-
Parallel Plate Capacitor Aluminum KIDs for Future Far-Infrared Space-Based Observatories
Authors:
Nicholas F. Cothard,
Christopher Albert,
Andrew D. Beyer,
Charles M. Bradford,
Pierre Echternach,
Byeong-Ho Eom,
Logan Foote,
Marc Foote,
Steven Hailey-Dunsheath,
Reinier M. J. Janssen,
Elijah Kane,
Henry LeDuc,
Joanna Perido,
Jason Glenn,
Peter K. Day
Abstract:
Future space-based far-infrared astrophysical observatories will require exquis-itely sensitive detectors consistent with the low optical backgrounds. The PRobe far-Infrared Mission for Astrophysics (PRIMA) will deploy arrays of thousands of superconducting kinetic inductance detectors (KIDs) sensitive to radiation between 25 and 265 $μ$m. Here, we present laboratory characterization of prototype,…
▽ More
Future space-based far-infrared astrophysical observatories will require exquis-itely sensitive detectors consistent with the low optical backgrounds. The PRobe far-Infrared Mission for Astrophysics (PRIMA) will deploy arrays of thousands of superconducting kinetic inductance detectors (KIDs) sensitive to radiation between 25 and 265 $μ$m. Here, we present laboratory characterization of prototype, 25 -- 80 $μ$m wavelength, low-volume, aluminum KIDs designed for the low-background environment expected with PRIMA. A compact parallel plate capacitor is used to minimize the detector footprint and suppress TLS noise. A novel resonant absorber is designed to enhance response in the band of interest. We present noise and optical efficiency measurements of these detectors taken with a low-background cryostat and a cryogenic blackbody. A microlens-hybridized KID array is found to be photon noise limited down to about 50 aW with a limiting detector NEP of about $6.5 \times 10^{-19}~\textrm{W/Hz}^{1/2}$. A fit to an NEP model shows that our optical system is well characterized and understood down to 50 aW. We discuss future plans for low-volume aluminum KID array development as well as the testbeds used for these measurements.
△ Less
Submitted 1 November, 2023;
originally announced November 2023.
-
Lens Absorber Coupled MKIDs for Far Infrared Imaging Spectroscopy
Authors:
Shahab O. Dabironezare,
Sven van Berkel,
Pierre M. Echternach,
Peter K. Day,
Charles M. Bradford,
Jochem J. A. Baselmans
Abstract:
Future generation of astronomical imaging spectrometers are targeting the far infrared wavelengths to close the THz astronomy gap. Similar to lens antenna coupled Microwave Kinetic Inductance Detectors (MKIDs), lens absorber coupled MKIDs are a candidate for highly sensitive large format detector arrays. However, the latter is more robust to misalignment and assembly issues at THz frequencies due…
▽ More
Future generation of astronomical imaging spectrometers are targeting the far infrared wavelengths to close the THz astronomy gap. Similar to lens antenna coupled Microwave Kinetic Inductance Detectors (MKIDs), lens absorber coupled MKIDs are a candidate for highly sensitive large format detector arrays. However, the latter is more robust to misalignment and assembly issues at THz frequencies due to its incoherent detection mechanism while requiring a less complex fabrication process. In this work, the performance of such detectors is investigated. The fabrication and sensitivity measurement of several lens absorber coupled MKID array prototypes operating at 6.98 and 12 THz central frequencies is on-going.
△ Less
Submitted 27 October, 2023;
originally announced October 2023.
-
Wideband Direct Detection Constraints on Hidden Photon Dark Matter with the QUALIPHIDE Experiment
Authors:
Karthik Ramanathan,
Nikita Klimovich,
Ritoban Basu Thakur,
Byeong Ho Eom,
Henry G. LeDuc,
Shibo Shu,
Andrew D. Beyer,
Peter K. Day
Abstract:
We report direction detection constraints on the presence of hidden photon dark matter with masses between 20-30 ueV using a cryogenic emitter-receiver-amplifier spectroscopy setup designed as the first iteration of QUALIPHIDE (QUantum LImited PHotons In the Dark Experiment). A metallic dish sources conversion photons from hidden photon kinetic mixing onto a horn antenna which is coupled to a C-ba…
▽ More
We report direction detection constraints on the presence of hidden photon dark matter with masses between 20-30 ueV using a cryogenic emitter-receiver-amplifier spectroscopy setup designed as the first iteration of QUALIPHIDE (QUantum LImited PHotons In the Dark Experiment). A metallic dish sources conversion photons from hidden photon kinetic mixing onto a horn antenna which is coupled to a C-band kinetic inductance traveling wave parametric amplifier, providing for near quantum-limited noise performance. We demonstrate a first probing of the kinetic mixing parameter "chi" to just above 10^-12 for the majority of hidden photon masses in this region. These results not only represent stringent constraints on new dark matter parameter space but are also the first demonstrated use of wideband quantum-limited amplification for astroparticle applications
△ Less
Submitted 7 September, 2022;
originally announced September 2022.
-
Strong kinetic-inductance Kerr nonlinearity with titanium nitride nanowires
Authors:
Chaitali Joshi,
Wenyuan Chen,
Henry G. LeDuc,
Peter K. Day,
Mohammad Mirhosseini
Abstract:
Thin films of disordered superconductors such as titanium nitride (TiN) exhibit large kinetic inductance (KI), high critical temperature, and large quality factors at the single-photon level. KI nonlinearity can be exploited as an alternative to Josephson junctions for creating novel nonlinear quantum devices with the potential to operate at higher frequencies and at elevated temperatures. We stud…
▽ More
Thin films of disordered superconductors such as titanium nitride (TiN) exhibit large kinetic inductance (KI), high critical temperature, and large quality factors at the single-photon level. KI nonlinearity can be exploited as an alternative to Josephson junctions for creating novel nonlinear quantum devices with the potential to operate at higher frequencies and at elevated temperatures. We study a means of magnifying KI nonlinearity by confining the current density of resonant electromagnetic modes in nanowires with a small volume $V \simeq 10^{-4}\text{um}^3$. Using this concept, we realize microwave-frequency Kerr cavities with a maximum Kerr-shift per photon of $K/2π= 123.5 \pm 3$ kHz and report a nonlinearity-to-linewidth ratio $K/γ= 21\%$. With improved design, our devices are expected to approach the regime of strong quantum nonlinearity in the millimeter-wave spectrum.
△ Less
Submitted 30 July, 2022;
originally announced August 2022.
-
A quantum electromechanical interface for long-lived phonons
Authors:
Alkim Bozkurt,
Han Zhao,
Chaitali Joshi,
Henry G. LeDuc,
Peter K. Day,
Mohammad Mirhosseini
Abstract:
Controlling long-lived mechanical oscillators in the quantum regime holds promises for quantum information processing. Here, we present an electromechanical system capable of operating in the GHz-frequency band in a silicon-on-insulator platform. Relying on a novel driving scheme based on an electrostatic field and high-impedance microwave cavities based on TiN superinductors, we are able to demon…
▽ More
Controlling long-lived mechanical oscillators in the quantum regime holds promises for quantum information processing. Here, we present an electromechanical system capable of operating in the GHz-frequency band in a silicon-on-insulator platform. Relying on a novel driving scheme based on an electrostatic field and high-impedance microwave cavities based on TiN superinductors, we are able to demonstrate a parametrically-enhanced electromechanical coupling of ${g/2 π} = 1.1$ MHz, sufficient to enter the strong-coupling regime with a cooperativity of $\mathcal{C} = 1200$. The absence of piezoelectric materials in our platform leads to long mechanical lifetimes, finding intrinsic values up to $τ_\text{d} = 265~ μ$s ($Q = 8.4 \times {10}^6$ at $ω_\mathrm{m}/2π= 5$ GHz) measured at low-phonon numbers and millikelvin temperatures. Despite the strong parametric drives, we find the cavity-mechanics system in the quantum ground state by performing sideband thermometry measurements. Simultaneously achieving ground-state operation, long mechanical lifetimes, and strong coupling sets the stage for employing silicon electromechanical resonators as memory elements and transducers in hybrid quantum systems, and as a tool for probing the origins of acoustic loss in the quantum regime.
△ Less
Submitted 22 July, 2022;
originally announced July 2022.
-
A multi-chroic kinetic inductance detectors array using hierarchical phased array antenna
Authors:
Shibo Shu,
Andrew Beyer,
Peter K. Day,
Fabien Defrance,
Jack Sayers,
Sunil Golwala
Abstract:
We present a multi-chroic kinetic inductance detector (KID) pixel design integrated with a broadband hierarchical phased-array antenna. Each low-frequency pixel consists of four high-frequency pixels. Four passbands are designed from 125 to 365 GHz according to the atmospheric windows. The lumped element KIDs consist of 100-nm thick AlMn inductors and Nb parallel plate capacitors with hydrogenated…
▽ More
We present a multi-chroic kinetic inductance detector (KID) pixel design integrated with a broadband hierarchical phased-array antenna. Each low-frequency pixel consists of four high-frequency pixels. Four passbands are designed from 125 to 365 GHz according to the atmospheric windows. The lumped element KIDs consist of 100-nm thick AlMn inductors and Nb parallel plate capacitors with hydrogenated amorphous Si dielectric. Two different coupling structures are designed to couple millimeter-wave from microstrip lines to KIDs. The KID designs are optimized for a 10-m-class telescope at a high, dry site, for example, the Leighton Chajnantor Telescope. Preliminary measurement results using Al KIDs are discussed.
△ Less
Submitted 4 October, 2022; v1 submitted 10 December, 2021;
originally announced December 2021.
-
A kinetic inductance detectors array design for high background conditions at 150 GHz
Authors:
Shibo Shu,
Jack Sayers,
Peter K. Day
Abstract:
We present a design for an array of kinetic inductance detectors (KIDs) integrated with phased array antennas for imaging at 150 GHz under high background conditions. The microstrip geometry KID detectors are projected to achieve photon noise limited sensitivity with larger than 100 pW absorbed optical power. Both the microstrip KIDs and the antenna feed network make use of a low-loss amorphous si…
▽ More
We present a design for an array of kinetic inductance detectors (KIDs) integrated with phased array antennas for imaging at 150 GHz under high background conditions. The microstrip geometry KID detectors are projected to achieve photon noise limited sensitivity with larger than 100 pW absorbed optical power. Both the microstrip KIDs and the antenna feed network make use of a low-loss amorphous silicon dielectric. A new aspect of the antenna implementation is the use of a NbTiN microstrip feed network to facilitate impedance matching to the 50 Ohm antenna. The array has 256 pixels on a 6-inch wafer and each pixel has two polarizations with two Al KIDs. The KIDs are designed with a half wavelength microstrip transmission line with parallel plate capacitors at the two ends. The resonance frequency range is 400 to 800 MHz. The readout feedline is also implemented in microstrip and has an impedance transformer from 50 Ohm to 9 Ohm at its input and output.
△ Less
Submitted 25 May, 2022; v1 submitted 10 December, 2021;
originally announced December 2021.
-
Development of Superconducting On-chip Fourier Transform Spectrometers
Authors:
R. Basu Thakur,
A. Steiger,
S. Shu,
F. Faramarzi,
N. Klimovich,
P. K. Day,
E. Shirokoff,
P. D. Mauskopf,
P. S. Barry
Abstract:
Superconducting On-chip Fourier Transform Spectrometers (SOFTS) are broadband, compact and electronic interferometers. Being extremely compact, SOFTS can fit into standard antenna coupled detector architectures. SOFTS will enable kilo-pixel spectro-imaging focal planes enhancing sub-millimeter science; particularly cluster astrophysics / cosmology, CMB-science and line intensity map**. This proc…
▽ More
Superconducting On-chip Fourier Transform Spectrometers (SOFTS) are broadband, compact and electronic interferometers. Being extremely compact, SOFTS can fit into standard antenna coupled detector architectures. SOFTS will enable kilo-pixel spectro-imaging focal planes enhancing sub-millimeter science; particularly cluster astrophysics / cosmology, CMB-science and line intensity map**. This proceeding details the development, design and bench-marking of RF on-chip architecture of SOFTS for Ka and W bands.
△ Less
Submitted 23 August, 2022; v1 submitted 11 November, 2021;
originally announced November 2021.
-
The Galaxy Evolution Probe
Authors:
Jason Glenn,
Charles M. Bradford,
Erik Rosolowsky,
Rashied Amini,
Katherine Alatalo,
Lee Armus,
Andrew J. Benson,
Tzu-Ching Chang,
Jeremy Darling,
Peter K. Day,
Jeanette Domber,
Duncan Farrah,
Brandon Hensley,
Sarah Lipscy,
Bradley Moore,
Seb Oliver,
Joanna Perido,
David Redding,
Michael Rodgers,
Raphael Shirley,
Howard A. Smith,
John B. Steeves,
Carole Tucker,
Jonas Zmuidzinas
Abstract:
The Galaxy Evolution Probe (GEP) is a concept for a mid- and far-infrared space observatory to measure key properties of large samples of galaxies with large and unbiased surveys. GEP will attempt to achieve zodiacal light and Galactic dust emission photon background-limited observations by utilizing a 6 Kelvin, 2.0 meter primary mirror and sensitive arrays of kinetic inductance detectors. It will…
▽ More
The Galaxy Evolution Probe (GEP) is a concept for a mid- and far-infrared space observatory to measure key properties of large samples of galaxies with large and unbiased surveys. GEP will attempt to achieve zodiacal light and Galactic dust emission photon background-limited observations by utilizing a 6 Kelvin, 2.0 meter primary mirror and sensitive arrays of kinetic inductance detectors. It will have two instrument modules: a 10 - 400 micron hyperspectral imager with spectral resolution R = 8 (GEP-I) and a 24 - 193 micron, R = 200 grating spectrometer (GEP-S). GEP-I surveys will identify star-forming galaxies via their thermal dust emission and simultaneously measure redshifts using polycyclic aromatic hydrocarbon emission lines. Galaxy luminosities derived from star formation and nuclear supermassive black hole accretion will be measured for each source, enabling the cosmic star formation history to be measured to much greater precision than previously possible. Using optically thin far-infrared fine-structure lines, surveys with GEP-S will measure the growth of metallicity in the hearts of galaxies over cosmic time and extraplanar gas will be mapped in spiral galaxies in the local universe to investigate feedback processes. The science case and mission architecture designed to meet the science requirements are described, and the kinetic inductance detector and readout electronics state of the art and needed developments are described. This paper supersedes the GEP concept study report cited in it by providing new content, including: a summary of recent mid-infrared KID development, a discussion of microlens array fabrication for mid-infrared KIDs, and additional context for galaxy surveys. The reader interested in more technical details may want to consult the concept study report.
△ Less
Submitted 1 September, 2021;
originally announced September 2021.
-
Initial Design of a W-band Superconducting Kinetic Inductance Qubit (Kineticon)
Authors:
Farzad B. Faramarzi,
Peter K. Day,
Jacob Glasby,
Sasha Sypkens,
Marco Colangelo,
Ralph Chamberlin,
Mohammad Mirhosseini,
Kevin Schmidt,
Karl K. Berggren Philip Mauskopf
Abstract:
Superconducting qubits are widely used in quantum computing research and industry. We describe a superconducting kinetic inductance qubit (and introduce the term Kineticon to describe it) operating at W-band frequencies with a nonlinear nanowire section that provides the anharmonicity required for two distinct quantum energy states. Operating the qubits at higher frequencies may relax the dilution…
▽ More
Superconducting qubits are widely used in quantum computing research and industry. We describe a superconducting kinetic inductance qubit (and introduce the term Kineticon to describe it) operating at W-band frequencies with a nonlinear nanowire section that provides the anharmonicity required for two distinct quantum energy states. Operating the qubits at higher frequencies may relax the dilution refrigerator temperature requirements for these devices and paves the path for multiplexing a large number of qubits. Millimeter-wave operation requires superconductors with relatively high $T_c$, which implies high gap frequency, 2$Δ/h$, beyond which photons break Cooper pairs. For example, NbTiN with $T_c =15\,\text{K}$ has a gap frequency near 1.4 THz, which is much higher than that of aluminum (90 GHz), allowing for operation throughout the millimeter-wave band. Here we describe a design and simulation of a W-band Kineticon qubit embedded in a 3-D cavity. We perform classical electromagnetic calculations of the resulting field distributions.
△ Less
Submitted 14 March, 2021; v1 submitted 15 December, 2020;
originally announced December 2020.
-
Superconducting On-chip Fourier Transform Spectrometer
Authors:
R. Basu Thakur,
N. Klimovich,
P. K . Day,
E. Shirokoff,
P. D. Mauskopf,
F. Faramarzi,
P. S. Barry
Abstract:
Kinetic inductance in thin film superconductors has been used as the basis for low-temperature, low-noise photon detectors. In particular thin films such as NbTiN, TiN, NbN, the kinetic inductance effect is strongly non-linear in the applied current, which can be utilized to realize novel devices. We present results from transmission lines made with these materials, where DC (current) control is u…
▽ More
Kinetic inductance in thin film superconductors has been used as the basis for low-temperature, low-noise photon detectors. In particular thin films such as NbTiN, TiN, NbN, the kinetic inductance effect is strongly non-linear in the applied current, which can be utilized to realize novel devices. We present results from transmission lines made with these materials, where DC (current) control is used to modulate the phase velocity thereby enabling an on-chip spectrometer. The utility of such compact spectrometers are discussed, along with their natural connection with parametric amplifiers.
△ Less
Submitted 4 September, 2019;
originally announced September 2019.
-
Electron-phonon coupling in Ti/TiN MKIDs multilayer microresonator
Authors:
Marco Faverzani,
Peter K. Day,
Elena Ferri,
Andrea Giachero,
Benno Margesin,
Renato Mezzena,
Angelo Nucciotti,
Andrei Puiu
Abstract:
Over the last few years there has been a growing interest toward the use of superconducting microwave microresonators operated in quasi-thermal equilibrium mode, especially applied to single particle detection. Indeed, previous devices designed and tested by our group with X-ray sources in the keV range evidenced that several issues arise from the attempt of detection through athermal quasiparticl…
▽ More
Over the last few years there has been a growing interest toward the use of superconducting microwave microresonators operated in quasi-thermal equilibrium mode, especially applied to single particle detection. Indeed, previous devices designed and tested by our group with X-ray sources in the keV range evidenced that several issues arise from the attempt of detection through athermal quasiparticles produced within direct strikes of X-rays in the superconductor material of the resonator. In order to prevent issues related to quasiparticles self-recombination and to avoid exchange of athermal phonons with the substrate, our group focused on the development of thermal superconducting microresonators. In this configuration resonators composed of multilayer films of Ti/TiN sense the temperature of an absorbing material. To maximize the thermal response, low critical temperature films are preferable. By lowering the critical temperature, though, the maximum probing power bearable by the resonators decrease abruptly because of the weakening of the electron-phonon coupling. A proper compromise has to be found in order to avoid signal to noise ratio degradation. In this contribution we report the latest measurement of the electron-phonon coupling.
△ Less
Submitted 13 November, 2017;
originally announced November 2017.
-
Development of Thermal Kinetic Inductance Detectors suitable for X-ray spectroscopy
Authors:
A. Giachero,
A. Cruciani,
A. D'Addabbo,
P. K. Day,
S. Di Domizio,
M. Faverzani,
E. Ferri,
B. Margesin,
M. Martinez,
R. Mezzena,
L. Minutolo,
A. Nucciotti,
A. Puiu,
M. Vignati
Abstract:
We report on the development of Thermal Kinetic Inductance Detectors (TKIDs) suitable to perform X-ray spectroscopy measurements. The aim is to implement MKIDs sensors working in thermal quasi-equilibrium mode to detect X-ray photons as pure calorimeters. The thermal mode is a variation on the MKID classical way of operation that has generated interest in recent years. TKIDs can offer the MKIDs in…
▽ More
We report on the development of Thermal Kinetic Inductance Detectors (TKIDs) suitable to perform X-ray spectroscopy measurements. The aim is to implement MKIDs sensors working in thermal quasi-equilibrium mode to detect X-ray photons as pure calorimeters. The thermal mode is a variation on the MKID classical way of operation that has generated interest in recent years. TKIDs can offer the MKIDs inherent multiplexibility in the frequency domain, a high spatial resolution comparable with CCDs, and an energy resolution theoretically limited only by thermodynamic fluctuations across the thermal weak links. Microresonators are built in Ti/TiN multilayer technology with the inductive part thermally coupled with a metal absorber on a suspended SiN membrane, to avoid escape of phonons from the film to the substrate. The mid-term goal is to optimize the single pixel design in term of superconducting critical temperatures, internal quality factors, kinetic inductance and spectral energy resolution. The final goal is to realize a demonstrator array for a next generation thousand pixels X-ray spectrometer. In this contribution, the status of the project after one year of developments is reported, with detailed reference to the microresonators design and simulations and to the fabrication process.
△ Less
Submitted 30 October, 2017;
originally announced October 2017.
-
Magnetic field dependence of the internal quality factor and noise performance of lumped-element kinetic inductance detectors
Authors:
Daniel Flanigan,
Bradley R. Johnson,
Maximilian H. Abitbol,
Sean Bryan,
Robin Cantor,
Peter K. Day,
Glenn Jones,
Philip Mauskopf,
Heather McCarrick,
Amber Miller,
Jonas Zmuidzinas
Abstract:
We present a technique for increasing the internal quality factor of kinetic inductance detectors (KIDs) by nulling ambient magnetic fields with a properly applied magnetic field. The KIDs used in this study are made from thin-film aluminum, they are mounted inside a light-tight package made from bulk aluminum, and they are operated near $150 \, \mathrm{mK}$. Since the thin-film aluminum has a sli…
▽ More
We present a technique for increasing the internal quality factor of kinetic inductance detectors (KIDs) by nulling ambient magnetic fields with a properly applied magnetic field. The KIDs used in this study are made from thin-film aluminum, they are mounted inside a light-tight package made from bulk aluminum, and they are operated near $150 \, \mathrm{mK}$. Since the thin-film aluminum has a slightly elevated critical temperature ($T_\mathrm{c} = 1.4 \, \mathrm{K}$), it therefore transitions before the package ($T_\mathrm{c} = 1.2 \, \mathrm{K}$), which also serves as a magnetic shield. On cooldown, ambient magnetic fields as small as approximately $30 \, \mathrm{μT}$ can produce vortices in the thin-film aluminum as it transitions because the bulk aluminum package has not yet transitioned and therefore is not yet shielding. These vortices become trapped inside the aluminum package below $1.2 \, \mathrm{K}$ and ultimately produce low internal quality factors in the thin-film superconducting resonators. We show that by controlling the strength of the magnetic field present when the thin film transitions, we can control the internal quality factor of the resonators. We also compare the noise performance with and without vortices present, and find no evidence for excess noise beyond the increase in amplifier noise, which is expected with increasing loss.
△ Less
Submitted 20 September, 2016;
originally announced September 2016.
-
Photon noise from chaotic and coherent millimeter-wave sources measured with horn-coupled, aluminum lumped-element kinetic inductance detectors
Authors:
Daniel Flanigan,
Heather McCarrick,
Glenn Jones,
Bradley R. Johnson,
Maximilian H. Abitbol,
Peter Ade,
Derek Araujo,
Kristi Bradford,
Robin Cantor,
George Che,
Peter K. Day,
Simon Doyle,
Carl Bjorn Kjellstrand,
Henry G LeDuc,
Michele Limon,
Vy Luu,
Philip Mauskopf,
Amber Miller,
Tony Mroczkowski,
Carole Tucker,
Jonas Zmuidzinas
Abstract:
We report photon-noise limited performance of horn-coupled, aluminum lumped-element kinetic inductance detectors at millimeter wavelengths. The detectors are illuminated by a millimeter-wave source that uses an active multiplier chain to produce radiation between 140 and 160 GHz. We feed the multiplier with either amplified broadband noise or a continuous-wave tone from a microwave signal generato…
▽ More
We report photon-noise limited performance of horn-coupled, aluminum lumped-element kinetic inductance detectors at millimeter wavelengths. The detectors are illuminated by a millimeter-wave source that uses an active multiplier chain to produce radiation between 140 and 160 GHz. We feed the multiplier with either amplified broadband noise or a continuous-wave tone from a microwave signal generator. We demonstrate that the detector response over a 40 dB range of source power is well-described by a simple model that considers the number of quasiparticles. The detector noise-equivalent power (NEP) is dominated by photon noise when the absorbed power is greater than approximately 1 pW, which corresponds to $\mathrm{NEP} \approx 2 \times 10^{-17} \, \mathrm{W} \, \mathrm{Hz}^{-1/2}$, referenced to absorbed power. At higher source power levels we observe the relationships between noise and power expected from the photon statistics of the source signal: $\mathrm{NEP} \propto P$ for broadband (chaotic) illumination and $\mathrm{NEP} \propto P^{1/2}$ for continuous-wave (coherent) illumination.
△ Less
Submitted 24 May, 2017; v1 submitted 22 October, 2015;
originally announced October 2015.
-
A frequency and sensitivity tunable microresonator array for high-speed quantum processor readout
Authors:
J. D. Whittaker,
L. J. Swenson,
M. H. Volkmann,
P. Spear,
F. Altomare,
A. J. Berkley,
B. Bumble,
P. Bunyk,
P. K. Day,
B. H. Eom,
R. Harris,
J. P. Hilton,
E. Hoskinson,
M. W. Johnson,
A. Kleinsasser,
E. Ladizinsky,
T. Lanting,
T. Oh,
I. Perminov,
E. Tolkacheva,
J. Yao
Abstract:
Superconducting microresonators have been successfully utilized as detection elements for a wide variety of applications. With multiplexing factors exceeding 1,000 detectors per transmission line, they are the most scalable low-temperature detector technology demonstrated to date. For high-throughput applications, fewer detectors can be coupled to a single wire but utilize a larger per-detector ba…
▽ More
Superconducting microresonators have been successfully utilized as detection elements for a wide variety of applications. With multiplexing factors exceeding 1,000 detectors per transmission line, they are the most scalable low-temperature detector technology demonstrated to date. For high-throughput applications, fewer detectors can be coupled to a single wire but utilize a larger per-detector bandwidth. For all existing designs, fluctuations in fabrication tolerances result in a non-uniform shift in resonance frequency and sensitivity, which ultimately limits the efficiency of band-width utilization. Here we present the design, implementation, and initial characterization of a superconducting microresonator readout integrating two tunable inductances per detector. We demonstrate that these tuning elements provide independent control of both the detector frequency and sensitivity, allowing us to maximize the transmission line bandwidth utilization. Finally we discuss the integration of these detectors in a multilayer fabrication stack for high-speed readout of the D-Wave quantum processor, highlighting the use of control and routing circuitry composed of single flux-quantum loops to minimize the number of control wires at the lowest temperature stage.
△ Less
Submitted 22 April, 2016; v1 submitted 18 September, 2015;
originally announced September 2015.
-
Development of microwave superconducting microresonators for neutrino mass measurement in the HOLMES framework
Authors:
A. Giachero,
P. K. Day,
P. Falferi,
M. Faverzani,
E. Ferri,
C. Giordano,
M. Maino,
B. Margesin,
R. Mezzena,
R. Nizzolo,
A. Nucciotti,
A. Puiu,
L. Zanetti
Abstract:
The European Research Council has recently funded HOLMES, a project with the aim of performing a calorimetric measurement of the electron neutrino mass measuring the energy released in the electron capture decay of 163Ho. The baseline for HOLMES are microcalorimeters coupled to Transition Edge Sensors (TESs) read out with rf-SQUIDs, for microwave multiplexing purposes. A promising alternative solu…
▽ More
The European Research Council has recently funded HOLMES, a project with the aim of performing a calorimetric measurement of the electron neutrino mass measuring the energy released in the electron capture decay of 163Ho. The baseline for HOLMES are microcalorimeters coupled to Transition Edge Sensors (TESs) read out with rf-SQUIDs, for microwave multiplexing purposes. A promising alternative solution is based on superconducting microwave resonators, that have undergone rapid development in the last decade. These detectors, called Microwave Kinetic Inductance Detectors (MKIDs), are inherently multiplexed in the frequency domain and suitable for even larger-scale pixel arrays, with theoretical high energy resolution and fast response. The aim of our activity is to develop arrays of microresonator detectors for X-ray spectroscopy and suitable for the calorimetric measurement of the energy spectra of 163Ho. Superconductive multilayer films composed by a sequence of pure Titanium and stoichiometric TiN layers show many ideal properties for MKIDs, such as low loss, large sheet resistance, large kinetic inductance, and tunable critical temperature $T_c$. We developed Ti/TiN multilayer microresonators with $T_c$ within the range from 70 mK to 4.5 K and with good uniformity. In this contribution we present the design solutions adopted, the fabrication processes and the characterization results.
△ Less
Submitted 19 January, 2016; v1 submitted 17 September, 2015;
originally announced September 2015.
-
Peculiar Velocity Constraints from Five-Band SZ Effect Measurements Towards RX J1347.5-1145 with MUSIC and Bolocam from the CSO
Authors:
Jack Sayers,
Michael Zemcov,
Jason Glenn,
Sunil R. Golwala,
Philip R. Maloney,
Seth R. Siegel,
Jordan Wheeler,
Clint Bockstiegel,
Spencer Brugger,
Nicole G. Czakon,
Peter K. Day,
Thomas P. Downes,
Ran P. Duan,
Jiansong Gao,
Matthew I. Hollister,
Albert Lam,
Henry G. LeDuc,
Benjamin A. Mazin,
Sean G. McHugh,
David A. Miller,
Tony K. Mroczkowski,
Omid Noroozian,
Hien T. Nguyen,
Simon J. Radford,
James A. Schlaerth
, et al. (3 additional authors not shown)
Abstract:
We present Sunyaev-Zel'dovich (SZ) effect measurements from wide-field images towards the galaxy cluster RX J1347.5-1145 obtained from the Caltech Submillimeter Observatory with the Multiwavelength Submillimeter Inductance Camera (MUSIC) at 147, 213, 281, and 337 GHz and with Bolocam at 140 GHz. As part of our analysis, we have used higher frequency data from Herschel-SPIRE and previously publishe…
▽ More
We present Sunyaev-Zel'dovich (SZ) effect measurements from wide-field images towards the galaxy cluster RX J1347.5-1145 obtained from the Caltech Submillimeter Observatory with the Multiwavelength Submillimeter Inductance Camera (MUSIC) at 147, 213, 281, and 337 GHz and with Bolocam at 140 GHz. As part of our analysis, we have used higher frequency data from Herschel-SPIRE and previously published lower frequency radio data to subtract the signal from the brightest dusty star-forming galaxies behind RX J1347.5-1145 and from the AGN in RX J1347.5-1145's BCG. Using these five-band SZ effect images, combined with X-ray spectroscopic measurements of the temperature of the intra-cluster medium (ICM) from Chandra, we constrain the ICM optical depth to be $τ_e = 7.33^{+0.96}_{-0.97} \times 10^{-3}$ and the ICM line of sight peculiar velocity to be $v_{pec} = -1040^{+870}_{-840}$ km s$^{-1}$. The errors for both quantities are limited by measurement noise rather than calibration uncertainties or astrophysical contamination, and significant improvements are possible with deeper observations. Our best-fit velocity is in good agreement with one previously published SZ effect analysis and in mild tension with the other, although some or all of that tension may be because that measurement samples a much smaller cluster volume. Furthermore, our best-fit optical depth implies a gas mass slightly larger than the Chandra-derived value, implying the cluster is elongated along the line of sight.
△ Less
Submitted 1 March, 2016; v1 submitted 9 September, 2015;
originally announced September 2015.
-
Antenna-coupled TES bolometers used in BICEP2, Keck array, and SPIDER
Authors:
P. A. R. Ade,
R. W. Aikin,
M. Amiri,
D. Barkats,
S. J. Benton,
C. A. Bischoff,
J. J. Bock,
J. A. Bonetti,
J. A. Brevik,
I. Buder,
E. Bullock,
G. Chattopadhyay,
G. Davis,
P. K. Day,
C. D. Dowell,
L. Duband,
J. P. Filippini,
S. Fliescher,
S. R. Golwala,
M. Halpern,
M. Hasselfield,
S. R. Hildebrandt,
G. C. Hilton,
V. Hristov,
H. Hui
, et al. (42 additional authors not shown)
Abstract:
We have developed antenna-coupled transition-edge sensor (TES) bolometers for a wide range of cosmic microwave background (CMB) polarimetry experiments, including BICEP2, Keck Array, and the balloon borne SPIDER. These detectors have reached maturity and this paper reports on their design principles, overall performance, and key challenges associated with design and production. Our detector arrays…
▽ More
We have developed antenna-coupled transition-edge sensor (TES) bolometers for a wide range of cosmic microwave background (CMB) polarimetry experiments, including BICEP2, Keck Array, and the balloon borne SPIDER. These detectors have reached maturity and this paper reports on their design principles, overall performance, and key challenges associated with design and production. Our detector arrays repeatedly produce spectral bands with 20%-30% bandwidth at 95, 150, or 220~GHz. The integrated antenna arrays synthesize symmetric co-aligned beams with controlled side-lobe levels. Cross-polarized response on boresight is typically ~0.5%, consistent with cross-talk in our multiplexed readout system. End-to-end optical efficiencies in our cameras are routinely 35% or higher, with per detector sensitivities of NET~300 uKrts. Thanks to the scalability of this design, we have deployed 2560 detectors as 1280 matched pairs in Keck Array with a combined instantaneous sensitivity of ~9 uKrts, as measured directly from CMB maps in the 2013 season. Similar arrays have recently flown in the SPIDER instrument, and development of this technology is ongoing.
△ Less
Submitted 2 February, 2015;
originally announced February 2015.
-
HOLMES - The Electron Capture Decay of 163Ho to Measure the Electron Neutrino Mass with sub-eV sensitivity
Authors:
B. Alpert,
M. Balata,
D. Bennett,
M. Biasotti,
C. Boragno,
C. Brofferio,
V. Ceriale,
D. Corsini,
P. K. Day,
M. De Gerone,
R. Dressler,
M. Faverzani,
E. Ferri,
J. Fowler,
F. Gatti,
A. Giachero,
J. Hays-Wehle,
S. Heinitz,
G. Hilton,
U. Koester,
M. Lusignoli,
M. Maino,
J. Mates,
S. Nisi,
R. Nizzolo
, et al. (13 additional authors not shown)
Abstract:
The European Research Council has recently funded HOLMES, a new experiment to directly measure the neutrino mass. HOLMES will perform a calorimetric measurement of the energy released in the decay of 163Ho. The calorimetric measurement eliminates systematic uncertainties arising from the use of external beta sources, as in experiments with beta spectrometers. This measurement was proposed in 1982…
▽ More
The European Research Council has recently funded HOLMES, a new experiment to directly measure the neutrino mass. HOLMES will perform a calorimetric measurement of the energy released in the decay of 163Ho. The calorimetric measurement eliminates systematic uncertainties arising from the use of external beta sources, as in experiments with beta spectrometers. This measurement was proposed in 1982 by A. De Rujula and M. Lusignoli, but only recently the detector technological progress allowed to design a sensitive experiment. HOLMES will deploy a large array of low temperature microcalorimeters with implanted 163Ho nuclei. The resulting mass sensitivity will be as low as 0.4 eV. HOLMES will be an important step forward in the direct neutrino mass measurement with a calorimetric approach as an alternative to spectrometry. It will also establish the potential of this approach to extend the sensitivity down to 0.1 eV. We outline here the project with its technical challenges and perspectives.
△ Less
Submitted 17 March, 2015; v1 submitted 16 December, 2014;
originally announced December 2014.
-
A LEKID-based CMB instrument design for large-scale observations in Greenland
Authors:
D. C. Araujo,
P. A. R. Ade,
J. R. Bond,
K. J. Bradford,
D. Chapman,
G. Che,
P. K. Day,
J. Didier,
S. Doyle,
H. K. Eriksen,
D. Flanigan,
C. E. Groppi,
S. N. Hillbrand,
B. R. Johnson,
G. Jones,
M. Limon,
A. D. Miller,
P. Mauskopf,
H. McCarrick,
T. Mroczkowski,
B. Reichborn-Kjennerud,
B. Smiley,
J. Sobrin,
I. K. Wehus,
J. Zmuidzinas
Abstract:
We present the results of a feasibility study, which examined deployment of a ground-based millimeter-wave polarimeter, tailored for observing the cosmic microwave background (CMB), to Isi Station in Greenland. The instrument for this study is based on lumped-element kinetic inductance detectors (LEKIDs) and an F/2.4 catoptric, crossed-Dragone telescope with a 500 mm aperture. The telescope is mou…
▽ More
We present the results of a feasibility study, which examined deployment of a ground-based millimeter-wave polarimeter, tailored for observing the cosmic microwave background (CMB), to Isi Station in Greenland. The instrument for this study is based on lumped-element kinetic inductance detectors (LEKIDs) and an F/2.4 catoptric, crossed-Dragone telescope with a 500 mm aperture. The telescope is mounted inside the receiver and cooled to $<\,4$ K by a closed-cycle $^4$He refrigerator to reduce background loading on the detectors. Linearly polarized signals from the sky are modulated with a metal-mesh half-wave plate that is rotated at the aperture stop of the telescope with a hollow-shaft motor based on a superconducting magnetic bearing. The modular detector array design includes at least 2300 LEKIDs, and it can be configured for spectral bands centered on 150~GHz or greater. Our study considered configurations for observing in spectral bands centered on 150, 210 and 267~GHz. The entire polarimeter is mounted on a commercial precision rotary air bearing, which allows fast azimuth scan speeds with negligible vibration and mechanical wear over time. A slip ring provides power to the instrument, enabling circular scans (360 degrees of continuous rotation). This mount, when combined with sky rotation and the latitude of the observation site, produces a hypotrochoid scan pattern, which yields excellent cross-linking and enables 34\% of the sky to be observed using a range of constant elevation scans. This scan pattern and sky coverage combined with the beam size (15~arcmin at 150~GHz) makes the instrument sensitive to $5 < \ell < 1000$ in the angular power spectra.
△ Less
Submitted 10 October, 2014; v1 submitted 10 July, 2014;
originally announced July 2014.
-
The Detector System for the Stratospheric Kinetic Inductance Polarimeter (SKIP)
Authors:
B. R. Johnson,
P. A. R. Ade,
D. Araujo,
K. J. Bradford,
D. Chapman,
P. K. Day,
J. Didier,
S. Doyle,
H. K. Eriksen,
D. Flanigan,
C. Groppi,
S. Hillbrand,
G. Jones,
M. Limon,
P. Mauskopf,
H. McCarrick,
A. Miller,
T. Mroczkowski,
B. Reichborn-Kjennerud,
B. Smiley,
J. Sobrin,
I. K. Wehus,
J. Zmuidzinas
Abstract:
The Stratospheric Kinetic Inductance Polarimeter (SKIP) is a proposed balloon-borne experiment designed to study the cosmic microwave background, the cosmic infrared background and Galactic dust emission by observing 1133 square degrees of sky in the Northern Hemisphere with launches from Kiruna, Sweden. The instrument contains 2317 single-polarization, horn-coupled, aluminum lumped-element kineti…
▽ More
The Stratospheric Kinetic Inductance Polarimeter (SKIP) is a proposed balloon-borne experiment designed to study the cosmic microwave background, the cosmic infrared background and Galactic dust emission by observing 1133 square degrees of sky in the Northern Hemisphere with launches from Kiruna, Sweden. The instrument contains 2317 single-polarization, horn-coupled, aluminum lumped-element kinetic inductance detectors (LEKID). The LEKIDs will be maintained at 100 mK with an adiabatic demagnetization refrigerator. The polarimeter operates in two configurations, one sensitive to a spectral band centered on 150 GHz and the other sensitive to 260 and 350 GHz bands. The detector readout system is based on the ROACH-1 board, and the detectors will be biased below 300 MHz. The detector array is fed by an F/2.4 crossed-Dragone telescope with a 500 mm aperture yielding a 15 arcmin FWHM beam at 150 GHz. To minimize detector loading and maximize sensitivity, the entire optical system will be cooled to 1 K. Linearly polarized sky signals will be modulated with a metal-mesh half-wave plate that is mounted at the telescope aperture and rotated by a superconducting magnetic bearing. The observation program consists of at least two, five-day flights beginning with the 150 GHz observations.
△ Less
Submitted 5 January, 2014; v1 submitted 1 August, 2013;
originally announced August 2013.
-
Operation of a titanium nitride superconducting microresonator detector in the nonlinear regime
Authors:
L. J. Swenson,
P. K. Day,
B. H. Eom,
H. G. Leduc,
N. Llombart,
C. M. McKenney,
O. Noroozian,
J. Zmuidzinas
Abstract:
If driven sufficiently strongly, superconducting microresonators exhibit nonlinear behavior including response bifurcation. This behavior can arise from a variety of physical mechanisms including heating effects, grain boundaries or weak links, vortex penetration, or through the intrinsic nonlinearity of the kinetic inductance. Although microresonators used for photon detection are usually driven…
▽ More
If driven sufficiently strongly, superconducting microresonators exhibit nonlinear behavior including response bifurcation. This behavior can arise from a variety of physical mechanisms including heating effects, grain boundaries or weak links, vortex penetration, or through the intrinsic nonlinearity of the kinetic inductance. Although microresonators used for photon detection are usually driven fairly hard in order to optimize their sensitivity, most experiments to date have not explored detector performance beyond the onset of bifurcation. Here we present measurements of a lumped-element superconducting microresonator designed for use as a far-infrared detector and operated deep into the nonlinear regime. The 1 GHz resonator was fabricated from a 22 nm thick titanium nitride film with a critical temperature of 2 K and a normal-state resistivity of $100\, μΩ\,$cm. We measured the response of the device when illuminated with 6.4 pW optical loading using microwave readout powers that ranged from the low-power, linear regime to 18 dB beyond the onset of bifurcation. Over this entire range, the nonlinear behavior is well described by a nonlinear kinetic inductance. The best noise-equivalent power of $2 \times 10^{-16}$ W/Hz$^{1/2}$ at 10 Hz was measured at the highest readout power, and represents a $\sim$10 fold improvement compared with operating below the onset of bifurcation.
△ Less
Submitted 18 May, 2013;
originally announced May 2013.
-
Status of MUSIC, the MUltiwavelength Sub/millimeter Inductance Camera
Authors:
Sunil R. Golwala,
Clint Bockstiegel,
Spencer Brugger,
Nicole G. Czakon,
Peter K. Day,
Thomas P. Downes,
Ran Duan,
Jiansong Gao,
Amandeep K. Gill,
Jason Glenn,
Matthew I. Hollister,
Henry G. LeDuc,
Philip R. Maloney,
Benjamin A. Mazin,
Sean G. McHugh,
David Miller,
Omid Noroozian,
Hien T. Nguyen,
Jack Sayers,
James A. Schlaerth,
Seth Siegel,
Anastasios K. Vayonakis,
Philip R. Wilson,
Jonas Zmuidzinas
Abstract:
We present the status of MUSIC, the MUltiwavelength Sub/millimeter Inductance Camera, a new instrument for the Caltech Submillimeter Observatory. MUSIC is designed to have a 14', diffraction-limited field-of-view instrumented with 2304 detectors in 576 spatial pixels and four spectral bands at 0.87, 1.04, 1.33, and 1.98 mm. MUSIC will be used to study dusty star-forming galaxies, galaxy clusters v…
▽ More
We present the status of MUSIC, the MUltiwavelength Sub/millimeter Inductance Camera, a new instrument for the Caltech Submillimeter Observatory. MUSIC is designed to have a 14', diffraction-limited field-of-view instrumented with 2304 detectors in 576 spatial pixels and four spectral bands at 0.87, 1.04, 1.33, and 1.98 mm. MUSIC will be used to study dusty star-forming galaxies, galaxy clusters via the Sunyaev-Zeldovich effect, and star formation in our own and nearby galaxies. MUSIC uses broadband superconducting phased-array slot-dipole antennas to form beams, lumped-element on-chip bandpass filters to define spectral bands, and microwave kinetic inductance detectors to senseincoming light. The focal plane is fabricated in 8 tiles consisting of 72 spatial pixels each. It is coupled to the telescope via an ambient temperature ellipsoidal mirror and a cold reimaging lens. A cold Lyot stop sits at the image of the primary mirror formed by the ellipsoidal mirror. Dielectric and metal mesh filters are used to block thermal infrared and out-of-band radiation. The instrument uses a pulse tube cooler and 3He/3He/4He closed-cycle cooler to cool the focal plane to below 250 mK. A multilayer shield attenuates Earth's magnetic field. Each focal plane tile is read out by a single pair of coaxes and a HEMT amplifier. The readout system consists of 16 copies of custom-designed ADC/DAC and IF boards coupled to the CASPER ROACH platform. We focus on recent updates on the instrument design and results from the commissioning of the full camera in 2012.
△ Less
Submitted 3 November, 2012;
originally announced November 2012.
-
MAKO: a pathfinder instrument for on-sky demonstration of low-cost 350 micron imaging arrays
Authors:
Loren J. Swenson,
Peter K. Day,
Charles D. Dowell,
Byeong H. Eom,
Matthew I. Hollister,
Robert Jarnot,
Attila Kovãcs,
Henry G. Leduc,
Christopher M. McKenney,
Ryan Monroe,
Tony Mroczkowski,
Hien T. Nguyen,
Jonas Zmuidzinas
Abstract:
Submillimeter cameras now have up to $10^4$ pixels (SCUBA 2). The proposed CCAT 25-meter submillimeter telescope will feature a 1 degree field-of-view. Populating the focal plane at 350 microns would require more than $10^6$ photon-noise limited pixels. To ultimately achieve this scaling, simple detectors and high-density multiplexing are essential. We are addressing this long-term challenge throu…
▽ More
Submillimeter cameras now have up to $10^4$ pixels (SCUBA 2). The proposed CCAT 25-meter submillimeter telescope will feature a 1 degree field-of-view. Populating the focal plane at 350 microns would require more than $10^6$ photon-noise limited pixels. To ultimately achieve this scaling, simple detectors and high-density multiplexing are essential. We are addressing this long-term challenge through the development of frequency-multiplexed superconducting microresonator detector arrays. These arrays use lumped-element, direct-absorption resonators patterned from titanium nitride films. We will discuss our progress toward constructing a scalable 350 micron pathfinder instrument focusing on fabrication simplicity, multiplexing density, and ultimately a low per-pixel cost.
△ Less
Submitted 1 November, 2012;
originally announced November 2012.
-
Crosstalk Reduction for Superconducting Microwave Resonator Arrays
Authors:
Omid Noroozian,
Peter K. Day,
Byeong Ho Eom,
Henry G. Leduc,
Jonas Zmuidzinas
Abstract:
Large-scale arrays of Microwave Kinetic Inductance Detectors (MKIDs) are attractive candidates for use in imaging instruments for next generation submillimeter-wave telescopes such as CCAT. We have designed and fabricated tightly packed ~250-pixel MKID arrays using lumped-element resonators etched from a thin layer of superconducting TiNx deposited on a silicon substrate. The high pixel packing de…
▽ More
Large-scale arrays of Microwave Kinetic Inductance Detectors (MKIDs) are attractive candidates for use in imaging instruments for next generation submillimeter-wave telescopes such as CCAT. We have designed and fabricated tightly packed ~250-pixel MKID arrays using lumped-element resonators etched from a thin layer of superconducting TiNx deposited on a silicon substrate. The high pixel packing density in our initial design resulted in large microwave crosstalk due to electromagnetic coupling between the resonators. Our second design eliminates this problem by adding a grounding shield and using a double-wound geometry for the meander inductor to allow conductors with opposite polarity to be in close proximity. In addition, the resonator frequencies are distributed in a checkerboard pattern across the array. We present details for the two resonator and array designs and describe a circuit model for the full array that predicts the distribution of resonator frequencies and the crosstalk level. We also show results from a new experimental technique that conveniently measures crosstalk without the need for an optical setup. Our results reveal an improvement in crosstalk from 57% in the initial design down to \leq 2% in the second design. The general procedure and design guidelines in this work are applicable to future large arrays employing microwave resonators.
△ Less
Submitted 25 June, 2012;
originally announced June 2012.
-
Position and energy-resolved particle detection using phonon-mediated microwave kinetic inductance detectors
Authors:
D. C. Moore,
S. R. Golwala,
B. Bumble,
B. Cornell,
P. K. Day,
H. G. LeDuc,
J. Zmuidzinas
Abstract:
We demonstrate position and energy-resolved phonon-mediated detection of particle interactions in a silicon substrate instrumented with an array of microwave kinetic inductance detectors (MKIDs). The relative magnitude and delay of the signal received in each sensor allows the location of the interaction to be determined with < 1 mm precision at 30 keV. Using this position information, variations…
▽ More
We demonstrate position and energy-resolved phonon-mediated detection of particle interactions in a silicon substrate instrumented with an array of microwave kinetic inductance detectors (MKIDs). The relative magnitude and delay of the signal received in each sensor allows the location of the interaction to be determined with < 1 mm precision at 30 keV. Using this position information, variations in the detector response with position can be removed, and an energy resolution of σ_E = 0.55 keV at 30 keV was measured. Since MKIDs can be fabricated from a single deposited film and are naturally multiplexed in the frequency domain, this technology can be extended to provide highly-pixelized athermal phonon sensors for ~1 kg scale detector elements. Such high-resolution, massive particle detectors would be applicable to next-generation rare-event searches such as the direct detection of dark matter, neutrinoless double-beta decay, or coherent neutrino-nucleus scattering.
△ Less
Submitted 10 June, 2012; v1 submitted 20 March, 2012;
originally announced March 2012.
-
A Wideband, Low-Noise Superconducting Amplifier with High Dynamic Range
Authors:
Byeong Ho Eom,
Peter K. Day,
Henry G. Leduc,
Jonas Zmuidzinas
Abstract:
Amplifiers are ubiquitous in electronics and play a fundamental role in a wide range of scientific measurements. From a user's perspective, an ideal amplifier has very low noise, operates over a broad frequency range, and has a high dynamic range - it is capable of handling strong signals with little distortion. Unfortunately, it is difficult to obtain all of these characteristics simultaneously.…
▽ More
Amplifiers are ubiquitous in electronics and play a fundamental role in a wide range of scientific measurements. From a user's perspective, an ideal amplifier has very low noise, operates over a broad frequency range, and has a high dynamic range - it is capable of handling strong signals with little distortion. Unfortunately, it is difficult to obtain all of these characteristics simultaneously. For example, modern transistor amplifiers offer multi-octave bandwidths and excellent dynamic range. However, their noise remains far above the fundamental limit set by the uncertainty principle of quantum mechanics. Parametric amplifiers, which predate transistor amplifiers and are widely used in optics, exploit a nonlinear response to transfer power from a strong pump tone to a weak signal. If the nonlinearity is purely reactive, ie. nondissipative, in theory the amplifier noise can reach the quantum-mechanical limit. Indeed, microwave frequency superconducting Josephson parametric amplifiers do approach the quantum limit, but generally are narrow band and have very limited dynamic range. In this paper, we describe a superconducting parametric amplifier that overcomes these limitations. The amplifier is very simple, consisting only of a patterned metal film on a dielectric substrate, and relies on the nonlinear kinetic inductance of a superconducting transmission line. We measure gain extending over 2 GHz on either side of an 11.56 GHz pump tone, and we place an upper limit on the added noise of the amplifier of 3.4 photons at 9.4 GHz. Furthermore, the dynamic range is very large, comparable to microwave transistor amplifiers, and the concept can be applied throughout the microwave, millimeter-wave and submillimeter-wave bands.
△ Less
Submitted 11 January, 2012;
originally announced January 2012.
-
Antenna-coupled TES Bolometer Arrays for BICEP2/Keck and SPIDER
Authors:
A. Orlando,
R. W Aikin,
M. Amiri,
J. J. Bock,
J. A. Bonetti,
J. A. Brevik,
B. Burger,
G. Chattopadthyay,
P. K. Day,
J. P. Filippini,
S. R. Golwala,
M. Halpern,
M. Hasselfield,
G. C. Hilton,
K. D. Irwin,
M. Kenyon,
J. M. Kovac,
C. L. Kuo,
A. E. Lange,
H. G. LeDuc,
N. Llombart,
H. T. Nguyen,
R. W. Ogburn,
C. D. Reintsema,
M. C. Runyan
, et al. (6 additional authors not shown)
Abstract:
BICEP2/Keck and SPIDER are cosmic microwave background (CMB) polarimeters targeting the B-mode polarization induced by primordial gravitational waves from inflation. They will be using planar arrays of polarization sensitive antenna-coupled TES bolometers, operating at frequencies between 90 GHz and 220 GHz. At 150 GHz each array consists of 64 polarimeters and four of these arrays are assembled t…
▽ More
BICEP2/Keck and SPIDER are cosmic microwave background (CMB) polarimeters targeting the B-mode polarization induced by primordial gravitational waves from inflation. They will be using planar arrays of polarization sensitive antenna-coupled TES bolometers, operating at frequencies between 90 GHz and 220 GHz. At 150 GHz each array consists of 64 polarimeters and four of these arrays are assembled together to make a focal plane, for a total of 256 dual-polarization elements (512 TES sensors). The detector arrays are integrated with a time-domain SQUID multiplexer developed at NIST and read out using the multi-channels electronics (MCE) developed at the University of British Columbia. Following our progress in improving detector parameters uniformity across the arrays and fabrication yield, our main effort has focused on improving detector arrays optical and noise performances, in order to produce science grade focal planes achieving target sensitivities. We report on changes in detector design implemented to optimize such performances and following focal plane arrays characterization. BICEP2 has deployed a first 150 GHz science grade focal plane to the South Pole in December 2009.
△ Less
Submitted 19 September, 2010;
originally announced September 2010.
-
Titanium Nitride Films for Ultrasensitive Microresonator Detectors
Authors:
Henry G. Leduc,
Bruce Bumble,
Peter K. Day,
Anthony D. Turner,
Byeong Ho Eom,
Sunil Golwala,
David C. Moore,
Omid Noroozian,
Jonas Zmuidzinas,
Jiansong Gao,
Benjamin A. Mazin,
Sean McHugh,
Andrew Merrill
Abstract:
Titanium nitride (TiNx) films are ideal for use in superconducting microresonator detectors because: a) the critical temperature varies with composition (0 < Tc < 5 K); b) the normal-state resistivity is large, ρ_n ~ 100 $μ$Ohm cm, facilitating efficient photon absorption and providing a large kinetic inductance and detector responsivity; and c) TiN films are very hard and mechanically robust. Res…
▽ More
Titanium nitride (TiNx) films are ideal for use in superconducting microresonator detectors because: a) the critical temperature varies with composition (0 < Tc < 5 K); b) the normal-state resistivity is large, ρ_n ~ 100 $μ$Ohm cm, facilitating efficient photon absorption and providing a large kinetic inductance and detector responsivity; and c) TiN films are very hard and mechanically robust. Resonators using reactively sputtered TiN films show remarkably low loss (Q_i > 10^7) and have noise properties similar to resonators made using other materials, while the quasiparticle lifetimes are reasonably long, 10-200 $μ$s. TiN microresonators should therefore reach sensitivities well below 10^-19 WHz^(-1/2).
△ Less
Submitted 9 August, 2010; v1 submitted 29 March, 2010;
originally announced March 2010.
-
Antenna-coupled TES bolometer arrays for CMB polarimetry
Authors:
C. L. Kuo,
J. J. Bock,
J. A. Bonetti,
J. Brevik,
G. Chattopadhyay,
P. K. Day,
S. Golwala,
M. Kenyon,
A. E. Lange,
H. G. LeDuc,
H. Nguyen,
R. W. Ogburn,
A. Orlando,
A. Trangsrud,
A. Turner,
G. Wang,
J. Zmuidzinas
Abstract:
We describe the design and performance of polarization selective antenna-coupled TES arrays that will be used in several upcoming Cosmic Microwave Background (CMB) experiments: SPIDER, BICEP-2/SPUD. The fully lithographic polarimeter arrays utilize planar phased-antennas for collimation (F/4 beam) and microstrip filters for band definition (25% bandwidth). These devices demonstrate high optical…
▽ More
We describe the design and performance of polarization selective antenna-coupled TES arrays that will be used in several upcoming Cosmic Microwave Background (CMB) experiments: SPIDER, BICEP-2/SPUD. The fully lithographic polarimeter arrays utilize planar phased-antennas for collimation (F/4 beam) and microstrip filters for band definition (25% bandwidth). These devices demonstrate high optical efficiency, excellent beam shapes, and well-defined spectral bands. The dual-polarization antennas provide well-matched beams and low cross polarization response, both important for high-fidelity polarization measurements. These devices have so far been developed for the 100 GHz and 150 GHz bands, two premier millimeter-wave atmospheric windows for CMB observations. In the near future, the flexible microstrip-coupled architecture can provide photon noise-limited detection for the entire frequency range of the CMBPOL mission. This paper is a summary of the progress we have made since the 2006 SPIE meeting in Orlando, FL.
△ Less
Submitted 11 August, 2009;
originally announced August 2009.
-
The Quantum Capacitor Detector: A Single Cooper Pair Box Based Readout for Pair Breaking Photo-detectors
Authors:
P. M. Echternach,
M. D. Shaw,
J. Bueno,
P. K. Day,
C. M. Bradford
Abstract:
We propose a sensitive new detector based on Cooper pair breaking in a superconductor. The quantum capacitor detector (QCD) exploits the extraordinary sensitivity of superconducting single-electron devices to the presence of quasiparticles generated by pair-breaking photons. This concept would enable single-photon detection at far-IR and sub-millimeter frequencies with detector sensitivities tha…
▽ More
We propose a sensitive new detector based on Cooper pair breaking in a superconductor. The quantum capacitor detector (QCD) exploits the extraordinary sensitivity of superconducting single-electron devices to the presence of quasiparticles generated by pair-breaking photons. This concept would enable single-photon detection at far-IR and sub-millimeter frequencies with detector sensitivities that exceed that of transition-edge-sensor bolometers (TES), kinetic inductance detectors (KID), and superconducting tunnel junction detectors (STJ). The detectors we propose are based on the single Cooper pair box (SCB), a mesoscopic superconducting device that has been successfully developed at JPL for applications in quantum computing. This concept allows for frequency multiplexing of a large number of pixels using a single RF line, and does not require individual bias of each pixel. The QCD is ideal for the sensitive spectrographs considered for upcoming cold space telescopes, such as BLISS for SPICA in the coming decade, and for the more ambitious instruments for the SAFIR / CALISTO and SPIRIT / SPECS missions envisioned for the 2020 decade. These missions require large detector arrays (> 10,000 elements) which are limited by astrophysical background noise, corresponding to a noise-equivalent power (NEP) as low as 2x10-20 W / Hz1/2. Given its intrinsic response time, the QCD could also be used for energy-resolved visible photon detection, with estimated energy resolution > 100, enabling imaging low-resolution spectroscopy with an array of detectors.
△ Less
Submitted 25 June, 2008;
originally announced June 2008.
-
A semi-empirical model for two-level system noise in superconducting microresonators
Authors:
Jiansong Gao,
Miguel Daal,
John M. Martinis,
Benjamin A. Mazin,
Peter K. Day,
Henry G. Leduc,
Anastasios Vayonakis,
Bernard Sadoulet,
Jonas Zmuidzinas
Abstract:
We present measurements of the low--temperature excess frequency noise of four niobium superconducting coplanar waveguide microresonators, with center strip widths $s_r$ ranging from 3 $μ$m to 20 $μ$m. For a fixed internal power, we find that the frequency noise decreases rapidly with increasing center strip width, scaling as $1/s_r^{1.6}$. We show that this geometrical scaling is readily explai…
▽ More
We present measurements of the low--temperature excess frequency noise of four niobium superconducting coplanar waveguide microresonators, with center strip widths $s_r$ ranging from 3 $μ$m to 20 $μ$m. For a fixed internal power, we find that the frequency noise decreases rapidly with increasing center strip width, scaling as $1/s_r^{1.6}$. We show that this geometrical scaling is readily explained by a simple semi-empirical model which assumes a surface distribution of independent two-level system fluctuators. These results allow the resonator geometry to be optimized for minimum noise.
△ Less
Submitted 3 April, 2008;
originally announced April 2008.
-
Temperature Dependence of the Frequency and Noise of Superconducting Coplanar Waveguide Resonators
Authors:
Shwetank Kumar,
Jiansong Gao,
Jonas Zmuidzinas,
Benjamin A. Mazin,
Henry G. LeDuc,
Peter K. Day
Abstract:
We present measurements of the temperature and power dependence of the resonance frequency and frequency noise of superconducting niobium thin-film coplanar waveguide resonators, carried out at temperatures well below the superconducting transition (T_{c}=9.2 K). The noise decreases by nearly two orders of magnitude as the temperature is increased from 120 to 1200 mK, while the variation of the…
▽ More
We present measurements of the temperature and power dependence of the resonance frequency and frequency noise of superconducting niobium thin-film coplanar waveguide resonators, carried out at temperatures well below the superconducting transition (T_{c}=9.2 K). The noise decreases by nearly two orders of magnitude as the temperature is increased from 120 to 1200 mK, while the variation of the resonance frequency with temperature over this range agrees well with the standard two-level system (TLS) model for amorphous dielectrics. These results support the hypothesis that TLS are responsible for the noise in superconducting microresonators, and have important implications for resonator applications such as qubits and photon detectors.
△ Less
Submitted 28 February, 2008;
originally announced February 2008.
-
A Position Sensitive X-ray Spectrophotometer using Microwave Kinetic Inductance Detectors
Authors:
Benjamin A. Mazin,
Megan E. Eckart,
Bruce Bumble,
Sunil Golwala,
Peter K. Day,
Jonas Zmuidzinas,
Fiona A. Harrison
Abstract:
The surface impedance of a superconductor changes when energy is absorbed and Cooper pairs are broken to produce single electron (quasiparticle) excitations. This change may be sensitively measured using a thin-film resonant circuit called a microwave kinetic inductance detector (MKID). The practical application of MKIDs for photon detection requires a method of efficiently coupling the photon e…
▽ More
The surface impedance of a superconductor changes when energy is absorbed and Cooper pairs are broken to produce single electron (quasiparticle) excitations. This change may be sensitively measured using a thin-film resonant circuit called a microwave kinetic inductance detector (MKID). The practical application of MKIDs for photon detection requires a method of efficiently coupling the photon energy to the MKID. We present results on position sensitive X-ray detectors made by using two aluminum MKIDs on either side of a tantalum photon absorber strip. Diffusion constants, recombination times, and energy resolution are reported. MKIDs can easily be scaled into large arrays.
△ Less
Submitted 4 October, 2006;
originally announced October 2006.
-
Noise Properties of Superconducting Coplanar Waveguide Microwave Resonators
Authors:
Jiansong Gao,
Benjamin A. Mazin,
Peter K. Day,
Jonas Zmuidzinas,
Henry G. LeDuc
Abstract:
We have measured noise in thin-film superconducting coplanar waveguide resonators. This noise appears entirely as phase noise, equivalent to a jitter of the resonance frequency. In contrast, amplitude fluctuations are not observed at the sensitivity of our measurement. The ratio between the noise power in the phase and amplitude directions is large, in excess of 30 dB. These results have importa…
▽ More
We have measured noise in thin-film superconducting coplanar waveguide resonators. This noise appears entirely as phase noise, equivalent to a jitter of the resonance frequency. In contrast, amplitude fluctuations are not observed at the sensitivity of our measurement. The ratio between the noise power in the phase and amplitude directions is large, in excess of 30 dB. These results have important implications for resonant readouts of various devices such as detectors, amplifiers, and qubits. We suggest that the phase noise is due to two-level systems in dielectric materials.
△ Less
Submitted 2 February, 2007; v1 submitted 24 September, 2006;
originally announced September 2006.