-
Speckle Space-Time Covariance in High-Contrast Imaging
Authors:
Briley L. Lewis,
Michael P. Fitzgerald,
Rupert H. Dodkins,
Kristina K. Davis,
Jonathan Lin
Abstract:
We introduce a new framework for point-spread function (PSF) subtraction based on the spatio-temporal variation of speckle noise in high-contrast imaging data where the sampling timescale is faster than the speckle evolution timescale. One way that space-time covariance arises in the pupil is as atmospheric layers translate across the telescope aperture and create small, time-varying perturbations…
▽ More
We introduce a new framework for point-spread function (PSF) subtraction based on the spatio-temporal variation of speckle noise in high-contrast imaging data where the sampling timescale is faster than the speckle evolution timescale. One way that space-time covariance arises in the pupil is as atmospheric layers translate across the telescope aperture and create small, time-varying perturbations in the phase of the incoming wavefront. The propagation of this field to the focal plane preserves some of that space-time covariance. To utilize this covariance, our new approach uses a Karhunen-Loéve transform on an image sequence, as opposed to a set of single reference images as in previous applications of Karhunen-Loéve Image Processing (KLIP) for high-contrast imaging. With the recent development of photon-counting detectors, such as microwave kinetic inductance detectors (MKIDs), this technique now has the potential to improve contrast when used as a post-processing step. Preliminary testing on simulated data shows this technique can improve contrast by at least 10-20% from the original image, with significant potential for further improvement. For certain choices of parameters, this algorithm may provide larger contrast gains than spatial-only KLIP.
△ Less
Submitted 3 January, 2023;
originally announced January 2023.
-
SCExAO and Keck Direct Imaging Discovery of a Low-Mass Companion Around the Accelerating F5 Star HIP 5319
Authors:
Noah Swimmer,
Thayne Currie,
Sarah Steiger,
Gregory Mirek Brandt,
Timothy D. Brandt,
Olivier Guyon,
Masayuki Kuzuhara,
Jeffrey Chilcote,
Taylor Tobin,
Tyler D. Groff,
Julien Lozi,
John I. Bailey III,
Alexander B. Walter,
Neelay Fruitwala,
Nicholas Zobrist,
Jennifer Pearl Smith,
Gregoire Coiffard,
Rupert Dodkins,
Kristina K. Davis,
Miguel Daal,
Bruce Bumble,
Sebastien Vievard,
Nour Skaf,
Vincent Deo,
Nemanja Jovanovic
, et al. (4 additional authors not shown)
Abstract:
We present the direct imaging discovery of a low-mass companion to the nearby accelerating F star, HIP 5319, using SCExAO coupled with the CHARIS, VAMPIRES, and MEC instruments in addition to Keck/NIRC2 imaging. CHARIS $JHK$ (1.1-2.4 $μ$m) spectroscopic data combined with VAMPIRES 750 nm, MEC $Y$, and NIRC2 $L_{\rm p}$ photometry is best matched by an M3--M7 object with an effective temperature of…
▽ More
We present the direct imaging discovery of a low-mass companion to the nearby accelerating F star, HIP 5319, using SCExAO coupled with the CHARIS, VAMPIRES, and MEC instruments in addition to Keck/NIRC2 imaging. CHARIS $JHK$ (1.1-2.4 $μ$m) spectroscopic data combined with VAMPIRES 750 nm, MEC $Y$, and NIRC2 $L_{\rm p}$ photometry is best matched by an M3--M7 object with an effective temperature of T=3200 K and surface gravity log($g$)=5.5. Using the relative astrometry for HIP 5319 B from CHARIS and NIRC2 and absolute astrometry for the primary from $Gaia$ and $Hipparcos$ and adopting a log-normal prior assumption for the companion mass, we measure a dynamical mass for HIP 5319 B of $31^{+35}_{-11}M_{\rm J}$, a semimajor axis of $18.6^{+10}_{-4.1}$ au, an inclination of $69.4^{+5.6}_{-15}$ degrees, and an eccentricity of $0.42^{+0.39}_{-0.29}$. However, using an alternate prior for our dynamical model yields a much higher mass of 128$^{+127}_{-88}M_{\rm J}$. Using data taken with the LCOGT NRES instrument we also show that the primary HIP 5319 A is a single star in contrast to previous characterizations of the system as a spectroscopic binary. This work underscores the importance of assumed priors in dynamical models for companions detected with imaging and astrometry and the need to have an updated inventory of system measurements.
△ Less
Submitted 30 July, 2022;
originally announced August 2022.
-
The MKID Science Data Pipeline
Authors:
Sarah Steiger,
John I. Bailey III,
Nicholas Zobrist,
Noah Swimmer,
Rupert Dodkins,
Kristina K. Davis,
Benjamin A. Mazin
Abstract:
We present The MKID Pipeline, a general use science data pipeline for the reduction and analysis of ultraviolet, optical and infrared (UVOIR) Microwave Kinetic Inductance Detector (MKID) data sets. This paper provides an introduction to the nature of MKID data sets, an overview of the calibration steps included in the pipeline, and an introduction to the implementation of the software.
We present The MKID Pipeline, a general use science data pipeline for the reduction and analysis of ultraviolet, optical and infrared (UVOIR) Microwave Kinetic Inductance Detector (MKID) data sets. This paper provides an introduction to the nature of MKID data sets, an overview of the calibration steps included in the pipeline, and an introduction to the implementation of the software.
△ Less
Submitted 2 March, 2022;
originally announced March 2022.
-
SCExAO/MEC and CHARIS Discovery of a Low Mass, 6 AU-Separation Companion to HIP 109427 using Stochastic Speckle Discrimination and High-Contrast Spectroscopy
Authors:
Sarah Steiger,
Thayne Currie,
Timothy D. Brandt,
Olivier Guyon,
Masayuki Kuzuhara,
Jeffrey Chilcote,
Tyler D. Groff,
Julien Lozi,
Alexander B. Walter,
Neelay Fruitwala,
John I. Bailey III,
Nicholas Zobrist,
Noah Swimmer,
Isabel Lipartito,
Jennifer Pearl Smith,
Clint Bockstiegel,
Seth R. Meeker,
Gregoire Coiffard,
Rupert Dodkins,
Paul Szypryt,
Kristina K. Davis,
Miguel Daal,
Bruce Bumble,
Sebastien Vievard,
Ananya Sahoo
, et al. (6 additional authors not shown)
Abstract:
We report the direct imaging discovery of a low-mass companion to the nearby accelerating A star, HIP 109427, with the Subaru Coronagraphic Extreme Adaptive Optics (SCExAO) instrument coupled with the MKID Exoplanet Camera (MEC) and CHARIS integral field spectrograph. CHARIS data reduced with reference star PSF subtraction yield 1.1-2.4 $μ$m spectra. MEC reveals the companion in $Y$ and $J$ band a…
▽ More
We report the direct imaging discovery of a low-mass companion to the nearby accelerating A star, HIP 109427, with the Subaru Coronagraphic Extreme Adaptive Optics (SCExAO) instrument coupled with the MKID Exoplanet Camera (MEC) and CHARIS integral field spectrograph. CHARIS data reduced with reference star PSF subtraction yield 1.1-2.4 $μ$m spectra. MEC reveals the companion in $Y$ and $J$ band at a comparable signal-to-noise ratio using stochastic speckle discrimination, with no PSF subtraction techniques. Combined with complementary follow-up $L_{\rm p}$ photometry from Keck/NIRC2, the SCExAO data favors a spectral type, effective temperature, and luminosity of M4-M5.5, 3000-3200 $K$, and $\log_{10}(L/L_{\rm \odot}) = -2.28^{+0.04}_{-0.04}$, respectively. Relative astrometry of HIP 109427 B from SCExAO/CHARIS and Keck/NIRC2, and complementary Gaia-Hipparcos absolute astrometry of the primary favor a semimajor axis of $6.55^{+3.0}_{-0.48}$ au, an eccentricity of $0.54^{+0.28}_{-0.15}$, an inclination of $66.7^{+8.5}_{-14}$ degrees, and a dynamical mass of $0.280^{+0.18}_{-0.059}$ $M_{\odot}$. This work shows the potential for extreme AO systems to utilize speckle statistics in addition to widely-used post-processing methods to directly image faint companions to nearby stars near the telescope diffraction limit.
△ Less
Submitted 12 July, 2021; v1 submitted 11 March, 2021;
originally announced March 2021.
-
The MKID Exoplanet Camera for Subaru SCExAO
Authors:
Alexander B. Walter,
Neelay Fruitwala,
Sarah Steiger,
John I. Bailey III,
Nicholas Zobrist,
Noah Swimmer,
Isabel Lipartito,
Jennifer Pearl Smith,
Seth R. Meeker,
Clint Bockstiegel,
Gregoire Coiffard,
Rupert Dodkins,
Paul Szypryt,
Kristina K. Davis,
Miguel Daal,
Bruce Bumble,
Giulia Collura,
Olivier Guyon,
Julien Lozi,
Sebastien Vievard,
Nemanja Jovanovic,
Frantz Martinache,
Thayne Currie,
Benjamin A. Mazin
Abstract:
We present the MKID Exoplanet Camera (MEC), a z through J band (800 - 1400 nm) integral field spectrograph located behind The Subaru Coronagraphic Extreme Adaptive Optics (SCExAO) at the Subaru Telescope on Maunakea that utilizes Microwave Kinetic Inductance Detectors (MKIDs) as the enabling technology for high contrast imaging. MEC is the first permanently deployed near-infrared MKID instrument a…
▽ More
We present the MKID Exoplanet Camera (MEC), a z through J band (800 - 1400 nm) integral field spectrograph located behind The Subaru Coronagraphic Extreme Adaptive Optics (SCExAO) at the Subaru Telescope on Maunakea that utilizes Microwave Kinetic Inductance Detectors (MKIDs) as the enabling technology for high contrast imaging. MEC is the first permanently deployed near-infrared MKID instrument and is designed to operate both as an IFU, and as a focal plane wavefront sensor in a multi-kHz feedback loop with SCExAO. The read noise free, fast time domain information attainable by MKIDs allows for the direct probing of fast speckle fluctuations that currently limit the performance of most high contrast imaging systems on the ground and will help MEC achieve its ultimate goal of reaching contrasts of $10^{-7}$ at 2$λ/ D$. Here we outline the instrument details of MEC including the hardware, firmware, and data reduction and analysis pipeline. We then discuss MEC's current on-sky performance and end with future upgrades and plans.
△ Less
Submitted 23 October, 2020;
originally announced October 2020.
-
Complex beam map** and Fourier optics analysis of a wide field Microwave Kinetic Inductance Detector camera
Authors:
S. J. C. Yates,
K. K. Davis,
W. Jellema,
J. J. A. Baselmans,
A. M. Baryshev
Abstract:
For astronomical instruments, accurate knowledge of the optical pointing and coupling are essential to characterize the alignment and performance of (sub-)systems prior to integration and deployment. Ideally, this requires the phase response of the optical system, which for direct (phase insensitive) detectors was not previously accessible. Here we show development of the phase sensitive complex b…
▽ More
For astronomical instruments, accurate knowledge of the optical pointing and coupling are essential to characterize the alignment and performance of (sub-)systems prior to integration and deployment. Ideally, this requires the phase response of the optical system, which for direct (phase insensitive) detectors was not previously accessible. Here we show development of the phase sensitive complex beam pattern technique using a dual optical source heterodyne technique for a large field of view Microwave Kinetic Inductance Detector camera at 350 GHz. We show here how you can analyze the measured data with Fourier optics, which allows integration into a telescope model to calculate the on sky beam pattern and telescope aperture efficiency prior to deployment at a telescope.
△ Less
Submitted 10 February, 2020;
originally announced February 2020.
-
Analysis techniques for complex-field radiation pattern measurements
Authors:
Kristina K. Davis,
Willem Jellema,
Stephen J. C. Yates,
Christopher E. Groppi,
Jochem J. A. Baselmans,
Andrey M. Baryshev
Abstract:
Complex field measurements are increasingly becoming the standard for state-of-the-art astronomical instrumentation. Complex field measurements have been used to characterize a suite of ground, airborne, and space-based heterodyne receiver missions [1], [2], [3], [4], [5], [6], and a description of how to acquire coherent field maps for direct detector arrays was demonstrated in Davis et. al. 2017…
▽ More
Complex field measurements are increasingly becoming the standard for state-of-the-art astronomical instrumentation. Complex field measurements have been used to characterize a suite of ground, airborne, and space-based heterodyne receiver missions [1], [2], [3], [4], [5], [6], and a description of how to acquire coherent field maps for direct detector arrays was demonstrated in Davis et. al. 2017. This technique has the ability to determine both amplitude and phase radiation patterns from individual pixels on an array. Phase information helps to better characterize the optical performance of the array (as compared to total power radiation patterns) by constraining the fit in an additional plane [4].
Here we discuss the mathematical framework used in an analysis pipeline developed to process complex field radiation pattern measurements. This routine determines and compensates misalignments of the instrument and scanning system. We begin with an overview of Gaussian beam formalism and how it relates to complex field pattern measurements. Next we discuss a scan strategy using an offset in z along the optical axis that allows first-order optical standing waves between the scanned source and optical system to be removed in post-processing. Also discussed is a method by which the co- and cross-polarization fields can be extracted individually for each pixel by rotating the two orthogonal measurement planes until the signal is the co-polarization map is maximized (and the signal in the cross-polarization field is minimized). We detail a minimization function that can fit measurement data to an arbitrary beam shape model. We conclude by discussing the angular plane wave spectral (APWS) method for beam propagation, including the near-field to far-field transformation.
△ Less
Submitted 21 September, 2018;
originally announced September 2018.
-
Surface wave control for large arrays of microwave kinetic inductance detectors
Authors:
Stephen J. C. Yates,
Andrey M. Baryshev,
Ozan Yurduseven,
Juan Bueno,
Kristina K. Davis,
Lorenza Ferrari,
Willem Jellema,
Nuria Llombart,
Vignesh Murugesan,
David J. Thoen,
Jochem J. A. Baselmans
Abstract:
Large ultra-sensitive detector arrays are needed for present and future observatories for far infra-red, submillimeter wave (THz), and millimeter wave astronomy. With increasing array size, it is increasingly important to control stray radiation inside the detector chips themselves, the surface wave. We demonstrate this effect with focal plane arrays of 880 lens-antenna coupled Microwave Kinetic I…
▽ More
Large ultra-sensitive detector arrays are needed for present and future observatories for far infra-red, submillimeter wave (THz), and millimeter wave astronomy. With increasing array size, it is increasingly important to control stray radiation inside the detector chips themselves, the surface wave. We demonstrate this effect with focal plane arrays of 880 lens-antenna coupled Microwave Kinetic Inductance Detectors (MKIDs). Presented here are near field measurements of the MKID optical response versus the position on the array of a reimaged optical source. We demonstrate that the optical response of a detector in these arrays saturates off-pixel at the $\sim-30$ dB level compared to the peak pixel response. The result is that the power detected from a point source at the pixel position is almost identical to the stray response integrated over the chip area. With such a contribution, it would be impossible to measure extended sources, while the point source sensitivity is degraded due to an increase of the stray loading. However, we show that by incorporating an on-chip stray light absorber, the surface wave contribution is reduced by a factor $>$10. With the on-chip stray light absorber the point source response is close to simulations down to the $\sim-35$ dB level, the simulation based on an ideal Gaussian illumination of the optics. In addition, as a crosscheck we show that the extended source response of a single pixel in the array with the absorbing grid is in agreement with the integral of the point source measurements.
△ Less
Submitted 7 July, 2017;
originally announced July 2017.