-
Change of 7Be decay rate in exohedral and endohedral C60 fullerene compounds and its implications
Authors:
A. Ray,
P. Das,
S. K. Saha,
S. K. Das,
J. J. Das,
N. Madhavan,
S. Nath,
P. Sugathan,
P. V. M. Rao,
A. Jhingan
Abstract:
The half-life of 7Be implanted in a C60 pellet and gold foil has been measured to be about the same within about 0.2%. Using a radiochemical technique, we also measured that the probability of formation of endohedral 7Be@C60 by nuclear implantation technique was (5.6+-0.45)%. It is known from earlier works that the half-life of endohedral 7Be@C60 is about 1.2% shorter than that of 7Be implanted…
▽ More
The half-life of 7Be implanted in a C60 pellet and gold foil has been measured to be about the same within about 0.2%. Using a radiochemical technique, we also measured that the probability of formation of endohedral 7Be@C60 by nuclear implantation technique was (5.6+-0.45)%. It is known from earlier works that the half-life of endohedral 7Be@C60 is about 1.2% shorter than that of 7Be implanted in gold. An analysis of these results using linear muffin-tin orbital method calculations indicates that most of the implanted 7Be ions in fullerene C60 stay at a distance of about 5.3 Angstrom from the centers of nearest C60 molecules forming exohedral compounds and those who enter the fullerene cages go to the centers of the cages forming endohedral 7Be@C60 compounds.
△ Less
Submitted 15 September, 2005;
originally announced September 2005.
-
Absence of M2 Retardation in $^{35}Cl$: Evidence for Stronger Isospin-Mixing Effects in A=35 Mirror Nuclei
Authors:
Ritesh Kshetri,
Indrani Ray,
P. Banerjee,
R. Raut,
A. Goswami,
J. M. Chatterjee,
S. Chattopadhyay,
U. Datta Pramanik,
A. Mukherjee,
C. C. Dey,
S. Bhattacharya,
B. Dasmahapatra,
M. Saha Sarkar,
S. Sarkar,
S. Bhowal,
G. Ganguly,
K. S. Golda,
R. Kumar,
R. P. Singh,
S. Muralithar,
P. V. Madhusudhana Rao,
N. Madhavan,
J. J. Das,
S. Nath,
P. Sugathan
, et al. (5 additional authors not shown)
Abstract:
The lifetime of the 3163 keV, 7/2$^-$ isomeric state in $^{35}Cl$ that decays by a stretched M2 transition to the $3/2^+$ ground state, has been re-measured using the Doppler Shift Attenuation Method, by gating on the 1185 keV transition which directly feeds this state. This eliminates the uncertainties in the measurement arising from the direct feedings from the continuum. A mean life of 0.6…
▽ More
The lifetime of the 3163 keV, 7/2$^-$ isomeric state in $^{35}Cl$ that decays by a stretched M2 transition to the $3/2^+$ ground state, has been re-measured using the Doppler Shift Attenuation Method, by gating on the 1185 keV transition which directly feeds this state. This eliminates the uncertainties in the measurement arising from the direct feedings from the continuum. A mean life of 0.6$^{+0.5}_{-0.2}$ ps has been obtained from the present work. This is considerably smaller than the adopted value 45.3(6) ps. Implication of this major reduction in the lifetime has been pointed out.
△ Less
Submitted 13 July, 2005;
originally announced July 2005.
-
Astrophysical S_{17}(0) factor from a measurement of d(7Be,8B)n reaction at E_{c.m.} = 4.5 MeV
Authors:
J. J. Das,
V. M. Datar,
P. Sugathan,
N. Madhavan,
P. V. Madhusudhana Rao,
A. Jhingan,
A. Navin,
S. K. Dhiman,
S. Barua,
S. Nath,
T. Varughese,
A. K. Sinha,
R. Singh,
A. Ray,
D. L. Sastry,
R. G. Kulkarni,
R. Shyam
Abstract:
Angular distribution measurements of $^2$H($^7$Be,$^7$Be)$^2$H and $^2$H($^7$Be,$^8$B)$n$ reactions at $E_{c.m.}\sim$~4.5 MeV were performed to extract the astrophysical $S_{17}(0)$ factor using the asymptotic normalization coefficient (ANC) method. For this purpose a pure, low emittance $^7$Be beam was separated from the primary $^7$Li beam by a recoil mass spectrometer operated in a novel mode…
▽ More
Angular distribution measurements of $^2$H($^7$Be,$^7$Be)$^2$H and $^2$H($^7$Be,$^8$B)$n$ reactions at $E_{c.m.}\sim$~4.5 MeV were performed to extract the astrophysical $S_{17}(0)$ factor using the asymptotic normalization coefficient (ANC) method. For this purpose a pure, low emittance $^7$Be beam was separated from the primary $^7$Li beam by a recoil mass spectrometer operated in a novel mode. A beam stopper at 0$^{\circ}$ allowed the use of a higher $^7$Be beam intensity. Measurement of the elastic scattering in the entrance channel using kinematic coincidence, facilitated the determination of the optical model parameters needed for the analysis of the transfer data. The present measurement significantly reduces errors in the extracted $^7$Be(p,$γ$) cross section using the ANC method. We get $S_{17}$~(0)~=~20.7~$\pm$~2.4 eV~b.
△ Less
Submitted 23 February, 2006; v1 submitted 21 September, 2004;
originally announced September 2004.