Time Projection Chamber (TPC) Detectors for Nuclear Astrophysics Studies With Gamma Beams
Authors:
M. Gai,
D. Schweitzer,
S. R. Stern,
A. H. Young,
R. Smith,
M. Cwiok,
J. S. Bihalowicz,
H. Czyrkowski,
R. Dabrowski,
W. Dominik,
A. Fijalkowska,
Z. Janas,
L. Janiak,
A. Korgul,
T. Matulewicz,
C. Mazzocchi,
M. Pfuetzner,
M. Zaremba,
D. Balabanski,
I. Gheorghe,
C. Matei,
O. Tesileanu,
N. V. Zamfir,
M. W. Ahmed,
S. S. Henshaw
, et al. (11 additional authors not shown)
Abstract:
Gamma-Beams at the HIgS facility in the USA and anticipated at the ELI-NP facility, now constructed in Romania, present unique new opportunities to advance research in nuclear astrophysics; not the least of which is resolving open questions in oxygen formation during stellar helium burning via a precise measurement of the 12C(a,g) reaction. Time projection chamber (TPC) detectors operating with lo…
▽ More
Gamma-Beams at the HIgS facility in the USA and anticipated at the ELI-NP facility, now constructed in Romania, present unique new opportunities to advance research in nuclear astrophysics; not the least of which is resolving open questions in oxygen formation during stellar helium burning via a precise measurement of the 12C(a,g) reaction. Time projection chamber (TPC) detectors operating with low pressure gas (as an active target) are ideally suited for such studies. We review the progress of the current research program and plans for the future at the HIγS facility with the optical readout TPC (O-TPC) and the development of an electronic readout TPC for the ELI-NP facility (ELITPC).
△ Less
Submitted 22 December, 2018;
originally announced December 2018.
-
A method for rapid determination of oil and water content in geological formations
Authors:
D. Vartsky,
M. B. Goldberg,
V. Dangendorf,
I. Israelashvili,
I. Mor,
D. Bar,
K. Tittelmeier,
M. Weierganz,
B. Bromberger,
A. Breskin
Abstract:
A novel method utilizing Fast Neutron Resonance Transmission Radiography is proposed for rapid, non-destructive and quantitative determination of the weight fractions of oil and water in cores taken from subterranean or underwater geological formations. Its ability to distinguish water from oil stems from the unambiguously-specific energy-dependence of the neutron cross-sections for the principal…
▽ More
A novel method utilizing Fast Neutron Resonance Transmission Radiography is proposed for rapid, non-destructive and quantitative determination of the weight fractions of oil and water in cores taken from subterranean or underwater geological formations. Its ability to distinguish water from oil stems from the unambiguously-specific energy-dependence of the neutron cross-sections for the principal elemental constituents. Furthermore, the fluid weight fractions permit determining core porosity and oil and water saturations. In this article we show results of experimental determination of oil and water weight fractions in 10 cm thick samples of Berea Sandstone and Indiana Limestone formations, followed by calculation of their porosity and fluid saturations. The technique may ultimately permit rapid, accurate and non-destructive evaluation of relevant petro-physical properties in thick intact cores. It is suitable for all types of formations including tight shales, clays and oil sands.
△ Less
Submitted 22 June, 2017;
originally announced June 2017.
-
Quantitative discrimination between oil and water in drilled bore cores via fast-neutron resonance transmission radiography
Authors:
D. Vartsky,
M. B. Goldberg,
V. Dangendorf,
I. Israelashvili,
I. Mor,
D. Bar,
K. Tittelmeier,
M. Weierganz,
A. Breskin
Abstract:
A novel method based on Fast Neutron Resonance Transmission Radiography is proposed for non-destructive, quantitative determination of the weight percentages of oil and water in cores taken from subterranean or underwater geological formations. The ability of the method to distinguish water from oil stems from the unambiguously-specific energy dependence of the neutron cross-sections for the princ…
▽ More
A novel method based on Fast Neutron Resonance Transmission Radiography is proposed for non-destructive, quantitative determination of the weight percentages of oil and water in cores taken from subterranean or underwater geological formations. The ability of the method to distinguish water from oil stems from the unambiguously-specific energy dependence of the neutron cross-sections for the principal elemental constituents. Monte-Carlo simulations and initial results of experimental investigations indicate that the technique may provide a rapid, accurate and non-destructive method for quantitative evaluation of core fluids in thick intact cores, including those of tight shales for which the use of conventional core analytical approaches appears to be questionable.
△ Less
Submitted 21 February, 2016;
originally announced February 2016.
-
Time-resolved fast-neutron radiography of air-water two-phase flows in a rectangular channel by an improved detection system
Authors:
Robert Zboray,
Volker Dangendorf,
Ilan Mor,
Benjamin Bromberger,
Kai Tittelmeier
Abstract:
In a previous work we have demonstrated the feasibility of high-frame-rate, fast-neutron radiography of generic air-water two-phase flows in a 1.5 cm thick, rectangular flow channel. The experiments have been carried out at the high-intensity, white-beam facility of the Physikalisch-Technische Bundesanstalt, Germany, using an multi-frame, time-resolved detector developed for fast neutron resonance…
▽ More
In a previous work we have demonstrated the feasibility of high-frame-rate, fast-neutron radiography of generic air-water two-phase flows in a 1.5 cm thick, rectangular flow channel. The experiments have been carried out at the high-intensity, white-beam facility of the Physikalisch-Technische Bundesanstalt, Germany, using an multi-frame, time-resolved detector developed for fast neutron resonance radiography. The results were however not fully optimal and therefore we have decided to modify the detector and optimize it for the given application, which is described in the present work. Furthermore, we managed to improve the image post-processing methodology and the noise suppression. Using the tailored detector and the improved post-processing significant increase in the image quality and an order of magnitude lower exposure times, down to 3.33 ms, have been achieved with minimized motion artifacts. Similar to the previous study, different two-phase flow regimes such as bubbly slug and churn flows have been examined. The enhanced imaging quality enables an improved prediction of two-phase flow parameters like the instantaneous volumetric gas fraction, bubble size and bubble velocities. Instantaneous velocity fields around the gas enclosures can also be more robustly predicted using optical flow methods as previously.
△ Less
Submitted 8 April, 2015;
originally announced April 2015.
-
High-frame rate, fast neutron imaging of two-phase flow in a thin rectangular channel
Authors:
R. Zboray,
I. Mor,
V. Dangendorf,
M. Stark,
K. Tittelmeier,
M. Cortesi,
R. Adams
Abstract:
We have demonstrated the feasibility of performing high-frame-rate, fast neutron radiography of air-water two-phase flows in a thin channel with rectangular cross section. The experiments have been carried out at the accelerator facility of the Physikalisch-Technische Bundesanstalt. A polychromatic, high-intensity fast neutron beam with average energy of 6 MeV was produced by 11.5 MeV deuterons hi…
▽ More
We have demonstrated the feasibility of performing high-frame-rate, fast neutron radiography of air-water two-phase flows in a thin channel with rectangular cross section. The experiments have been carried out at the accelerator facility of the Physikalisch-Technische Bundesanstalt. A polychromatic, high-intensity fast neutron beam with average energy of 6 MeV was produced by 11.5 MeV deuterons hitting a thick Be target. Image sequences down to 10 millisecond exposure times were obtained using a fast-neutron imaging detector developed in the context of fast-neutron resonance imaging. Different two-phase flow regimes such as bubbly slug and churn flows have been examined. Two phase flow parameters like the volumetric gas fraction, bubble size and bubble velocities have been measured. The first results are promising, improvements for future experiments are also discussed.
△ Less
Submitted 8 April, 2015;
originally announced April 2015.
-
Time-resolved neutron imaging at ANTARES cold neutron beamline
Authors:
A. S. Tremsin,
V. Dangendorf,
K. Tittelmeier,
B. Schillinger,
M. Schulz,
M. Lerche,
W. B. Feller
Abstract:
In non-destructive evaluation with X-rays light elements embedded in dense, heavy (or high-Z) matrices show little contrast and their structural details can hardly be revealed. Neutron radiography, on the other hand, provides a solution for those cases, in particular for hydrogenous materials, owing to the large neutron scattering cross section of hydrogen and uncorrelated dependency of neutron cr…
▽ More
In non-destructive evaluation with X-rays light elements embedded in dense, heavy (or high-Z) matrices show little contrast and their structural details can hardly be revealed. Neutron radiography, on the other hand, provides a solution for those cases, in particular for hydrogenous materials, owing to the large neutron scattering cross section of hydrogen and uncorrelated dependency of neutron cross section on the atomic number. The majority of neutron imaging experiments at the present time is conducted with static objects mainly due to the limited flux intensity of neutron beamline facilities and sometimes due to the limitations of the detectors. However, some applications require the studies of dynamic phenomena and can now be conducted at several high intensity beamlines such as the recently rebuilt ANTARES beam line at the FRM-II reactor. In this paper we demonstrate the capabilities of time resolved imaging for repetitive processes, where different phases of the process can be imaged simultaneously and integrated over multiple cycles. A fast MCP/Timepix neutron counting detector was used to image the water distribution within a model steam engine operating at 10 Hz frequency. Within <10 minutes integration the amount of water was measured as a function of cycle time with a sub-mm spatial resolution, thereby demonstrating the capabilities of time-resolved neutron radiography for the future applications. The neutron spectrum of the ANTARES beamline as well as transmission spectra of a Fe sample were also measured with the Time Of Flight (TOF) technique in combination with a high resolution beam chopper. The energy resolution of our setup was found to be ~0.8% at 5 meV and ~1.7% at 25 meV.
△ Less
Submitted 31 January, 2015;
originally announced February 2015.
-
Parameters Affecting Temporal Resolution of Time Resolved Integrative Optical Neutron Detector (TRION)
Authors:
I. Mor,
D. Vartsky,
V. Dangendorf,
D. Bar,
G. Feldman,
M. B. Goldberg,
K. Tittelmeier,
B. Bromberger,
M. Brandis,
M. Weierganz
Abstract:
The Time-Resolved Integrative Optical Neutron (TRION) detector was developed for Fast Neutron Resonance Radiography (FNRR), a fast-neutron transmission imaging method that exploits characteristic energy-variations of the total scattering cross-section in the En = 1-10 MeV range to detect specific elements within a radiographed object. As opposed to classical event-counting time of flight (ECTOF),…
▽ More
The Time-Resolved Integrative Optical Neutron (TRION) detector was developed for Fast Neutron Resonance Radiography (FNRR), a fast-neutron transmission imaging method that exploits characteristic energy-variations of the total scattering cross-section in the En = 1-10 MeV range to detect specific elements within a radiographed object. As opposed to classical event-counting time of flight (ECTOF), it integrates the detector signal during a well-defined neutron Time of Flight window corresponding to a pre-selected energy bin, e.g., the energy-interval spanning a cross-section resonance of an element such as C, O and N. The integrative characteristic of the detector permits loss-free operation at very intense, pulsed neutron fluxes, at a cost however, of recorded temporal resolution degradation.
This work presents a theoretical and experimental evaluation of detector related parameters which affect temporal resolution of the TRION system.
△ Less
Submitted 12 November, 2013;
originally announced November 2013.
-
Unambiguous Identification of the Second 2+ State in 12C and the Structure of the Hoyle State
Authors:
W. R. Zimmerman,
M. W. Ahmed,
B. Bromberger,
S. C. Stave,
A. Breskin,
V. Dangendorf,
Th. Delbar,
M. Gai,
S. S. Henshaw,
J. M. Mueller,
C. Sun,
K. Tittelmeier,
H. R. Weller,
Y. K. Wu
Abstract:
The second 2+ state of 12C, predicted over fifty years ago as an excitation of the Hoyle state, has been unambiguously identified using the 12C(g,a_0)8Be reaction. The alpha particles produced by the photodisintegration of 12C were detected using an Optical Time Projection Chamber (O-TPC). Data were collected at beam energies between 9.1 and 10.7 MeV using the intense nearly mono-energetic gamma-r…
▽ More
The second 2+ state of 12C, predicted over fifty years ago as an excitation of the Hoyle state, has been unambiguously identified using the 12C(g,a_0)8Be reaction. The alpha particles produced by the photodisintegration of 12C were detected using an Optical Time Projection Chamber (O-TPC). Data were collected at beam energies between 9.1 and 10.7 MeV using the intense nearly mono-energetic gamma-ray beams at the HIgS facility. The measured angular distributions determine the cross section and the E1-E2 relative phases as a function of energy leading to an unambiguous identification of the second 2+ state in 12C at 10.03(11) MeV, with a total width of 800(130) keV and a ground state gamma-decay width of 60(10) meV; B(E2: 2+ ---> gs) = 0.73(13) e2fm4 [or 0.45(8) W.u.]. The Hoyle state and its rotational 2+ state that are more extended than the ground state of 12C presents a challenge and constraints for models attempting to reveal the nature of three alpha particle states in 12C. Specifically it challenges the ab-initio Lattice Effective Field Theory (L-EFT) calculations that predict similar r.m.s. radii for the ground state and the Hoyle state.
△ Less
Submitted 18 March, 2013;
originally announced March 2013.
-
First studies of electron transport along small gas gaps of novel foil radiation converters for fast-neutron detectors
Authors:
M. Cortesi,
R. Zboray,
R. Adams,
V. Dangendorf,
A. Breskin,
S. Mayer,
H. Hoedlmoser,
H. -M. Prasser
Abstract:
Novel high efficiency fast-neutron detectors were suggested for fan-beam tomography applications. They combine multi-layer polymer converters in gas medium, coupled to thick gaseous electron multipliers (THGEM). In this work we discuss the results of a systematic study of the electron transport inside a narrow gap between successive converter foils, which affects the performance of the detector, b…
▽ More
Novel high efficiency fast-neutron detectors were suggested for fan-beam tomography applications. They combine multi-layer polymer converters in gas medium, coupled to thick gaseous electron multipliers (THGEM). In this work we discuss the results of a systematic study of the electron transport inside a narrow gap between successive converter foils, which affects the performance of the detector, both in terms of detection efficiency and localization properties. The efficiency of transporting ionization electrons was measured along a 0.6 mm wide gas gap in 6 and 10 mm wide polymer converters Computer simulations provided conceptual understanding of the observations. For a drift lengths of 6 mm electrons were efficiently transported along the narrow gas gap, with minimal diffusion-induced losses; an average collection efficiency of 95% was achieved for the ionization electrons induced by a primary electron of a few keV initial energy. The 10 mm height converter yielded considerably lower efficiency due to electrical and mechanical flaws of the converter foils. The results indicate that detection efficiencies of around 7% can be expected for 2.5 MeV neutrons with 300 foils converters, of 6 mm height, 0.4 mm thick foils and 0.6 mm gas gap.
△ Less
Submitted 19 December, 2012; v1 submitted 26 October, 2012;
originally announced October 2012.
-
Concept of a novel fast neutron imaging detector based on THGEM for fan-beam tomography applications
Authors:
M. Cortesi,
R. Zboray,
R. Adams,
V. Dangendorf,
H. -M. Prasser
Abstract:
The conceptual design and operational principle of a novel high-efficiency, fast neutron imaging detector based on THGEM, intended for future fan-beam transmission tomography applications, is described. We report on a feasibility study based on theoretical modeling and computer simulations of a possible detector configuration prototype. In particular we discuss results regarding the optimization o…
▽ More
The conceptual design and operational principle of a novel high-efficiency, fast neutron imaging detector based on THGEM, intended for future fan-beam transmission tomography applications, is described. We report on a feasibility study based on theoretical modeling and computer simulations of a possible detector configuration prototype. In particular we discuss results regarding the optimization of detector geometry, estimation of its general performance, and expected imaging quality: it has been estimated that detection efficiency of around 5-8% can be achieved for 2.5MeV neutrons; spatial resolution is around one millimeter with no substantial degradation due to scattering effects. The foreseen applications of the imaging system are neutron tomography in non-destructive testing for the nuclear energy industry, including examination of spent nuclear fuel bundles, detection of explosives or drugs, as well as investigation of thermal hydraulics phenomena (e.g., two-phase flow, heat transfer, phase change, coolant dynamics, and liquid metal flow).
△ Less
Submitted 1 March, 2012;
originally announced March 2012.
-
Time and position sensitive single photon detector for scintillator read-out
Authors:
Sven Schössler,
Benjamin Bromberger,
Michal Brandis,
Lothar Ph. H. Schmidt,
Kai Tittelmeier,
Achim Czasch,
Volker Dangendorf,
Ottmar Jagutzki
Abstract:
We have developed a photon counting detector system for combined neutron and gamma radiography which can determine position, time and intensity of a secondary photon flash created by a high-energy particle or photon within a scintillator screen. The system is based on a micro-channel plate photomultiplier concept utilizing image charge coupling to a position- and time-sensitive read-out anode plac…
▽ More
We have developed a photon counting detector system for combined neutron and gamma radiography which can determine position, time and intensity of a secondary photon flash created by a high-energy particle or photon within a scintillator screen. The system is based on a micro-channel plate photomultiplier concept utilizing image charge coupling to a position- and time-sensitive read-out anode placed outside the vacuum tube in air, aided by a standard photomultiplier and very fast pulse-height analyzing electronics. Due to the low dead time of all system components it can cope with the high throughput demands of a proposed combined fast neutron and dual discrete energy gamma radiography method (FNDDER). We show tests with different types of delay-line read-out anodes and present a novel pulse-height-to-time converter circuit with its potential to discriminate gamma energies for the projected FNDDER devices for an automated cargo container inspection system (ACCIS).
△ Less
Submitted 10 February, 2012; v1 submitted 12 January, 2012;
originally announced January 2012.
-
Monte-Carlo Simulations of Radiation-Induced Activation in a Fast-Neutron and Gamma- Based Cargo Inspection System
Authors:
B. Bromberger,
D. Bar,
M. Brandis,
V. Dangendorf,
M. B. Goldberg,
F. Kaufmann,
I. Mor,
R. Nolte,
M. Schmiedel,
K. Tittelmeier,
D. Vartsky,
H. Wershofen
Abstract:
An air cargo inspection system combining two nuclear reaction based techniques, namely Fast-Neutron Resonance Radiography and Dual-Discrete-Energy Gamma Radiography is currently being developed. This system is expected to allow detection of standard and improvised explosives as well as special nuclear materials. An important aspect for the applicability of nuclear techniques in an airport inspecti…
▽ More
An air cargo inspection system combining two nuclear reaction based techniques, namely Fast-Neutron Resonance Radiography and Dual-Discrete-Energy Gamma Radiography is currently being developed. This system is expected to allow detection of standard and improvised explosives as well as special nuclear materials. An important aspect for the applicability of nuclear techniques in an airport inspection facility is the inventory and lifetimes of radioactive isotopes produced by the neutron and gamma radiation inside the cargo, as well as the dose delivered by these isotopes to people in contact with the cargo during and following the interrogation procedure. Using MCNPX and CINDER90 we have calculated the activation levels for several typical inspection scenarios. One example is the activation of various metal samples embedded in a cotton-filled container. To validate the simulation results, a benchmark experiment was performed, in which metal samples were activated by fast-neutrons in a water-filled glass jar. The induced activity was determined by analyzing the gamma spectra. Based on the calculated radioactive inventory in the container, the dose levels due to the induced gamma radiation were calculated at several distances from the container and in relevant time windows after the irradiation, in order to evaluate the radiation exposure of the cargo handling staff, air crew and passengers during flight. The possibility of remanent long-lived radioactive inventory after cargo is delivered to the client is also of concern and was evaluated.
△ Less
Submitted 4 January, 2012;
originally announced January 2012.
-
Proof of principle of a high-spatial-resolution, resonant-response gamma-ray detector for Gamma Resonance Absorption in 14N
Authors:
M. Brandis,
M. B. Goldberg,
D. Vartsky,
E. Friedman,
I. Kreslo,
I. Mardor,
V. Dangendorf,
S. Levi,
I. Mor,
D. Bar
Abstract:
The development of a mm-spatial-resolution, resonant-response detector based on a micrometric glass capillary array filled with liquid scintillator is described. This detector was developed for Gamma Resonance Absorption (GRA) in 14N. GRA is an automatic-decision radiographic screening technique that combines high radiation penetration (the probe is a 9.17 MeV gamma ray) with very good sensitivity…
▽ More
The development of a mm-spatial-resolution, resonant-response detector based on a micrometric glass capillary array filled with liquid scintillator is described. This detector was developed for Gamma Resonance Absorption (GRA) in 14N. GRA is an automatic-decision radiographic screening technique that combines high radiation penetration (the probe is a 9.17 MeV gamma ray) with very good sensitivity and specificity to nitrogenous explosives. Detailed simulation of the detector response to electrons and protons generated by the 9.17 MeV gamma-rays was followed by a proof-of-principle experiment, using a mixed gamma-ray and neutron source. Towards this, a prototype capillary detector was assembled, including the associated filling and readout systems. Simulations and experimental results indeed show that proton tracks are distinguishable from electron tracks at relevant energies, on the basis of a criterion that combines track length and light intensity per unit length.
△ Less
Submitted 16 March, 2011;
originally announced March 2011.
-
An Optical Readout TPC (O-TPC) for Studies in Nuclear Astrophysics With Gamma-Ray Beams at HIgS
Authors:
M. Gai,
M. W. Ahmed,
S. C. Stave,
W. R. Zimmerman,
A. Breskin,
B. Bromberger,
R. Chechik,
V. Dangendorf,
Th. Delbar,
R. H. France III,
S. S. Henshaw,
T. J. Kading,
P. P. Martel,
J. E. R. McDonald,
P. -N. Seo,
K. Tittelmeier,
H. R. Weller,
A. H. Young
Abstract:
We report on the construction, tests, calibrations and commissioning of an Optical Readout Time Projection Chamber (O-TPC) detector operating with a CO2(80%) + N2(20%) gas mixture at 100 and 150 Torr. It was designed to measure the cross sections of several key nuclear reactions involved in stellar evolution. In particular, a study of the rate of formation of oxygen and carbon during the process o…
▽ More
We report on the construction, tests, calibrations and commissioning of an Optical Readout Time Projection Chamber (O-TPC) detector operating with a CO2(80%) + N2(20%) gas mixture at 100 and 150 Torr. It was designed to measure the cross sections of several key nuclear reactions involved in stellar evolution. In particular, a study of the rate of formation of oxygen and carbon during the process of helium burning will be performed by exposing the chamber gas to intense nearly mono-energetic gamma-ray beams at the High Intensity Gamma Source (HIgS) facility. The O-TPC has a sensitive target-drift volume of 30x30x21 cm^3. Ionization electrons drift towards a double parallel grid avalanche multiplier, yielding charge multiplication and light emission. Avalanche induced photons from N2 emission are collected, intensified and recorded with a Charge Coupled Device (CCD) camera, providing two-dimensional track images. The event's time projection (third coordinate) and the deposited energy are recorded by photomultipliers and by the TPC charge-signal, respectively. A dedicated VME-based data acquisition system and associated data analysis tools were developed to record and analyze these data. The O-TPC has been tested and calibrated with 3.183 MeV alpha-particles emitted by a 148Gd source placed within its volume with a measured energy resolution of 3.0%. Tracks of alpha and 12C particles from the dissociation of 16O and of three alpha-particles from the dissociation of 12C have been measured during initial in-beam test experiments performed at the HIgS facility at Duke University. The full detection system and its performance are described and the results of the preliminary in-beam test experiments are reported.
△ Less
Submitted 10 January, 2011;
originally announced January 2011.
-
Development of an LED reference light source for calibration of radiographic imaging detectors
Authors:
M. Weierganz,
D. Bar,
B. Bromberger,
V. Dangendorf,
G. Feldman,
M. B. Goldberg,
M. Lindemann,
I. Mor,
K. Tittelmeier,
D. Vartsky
Abstract:
A stable reference light source based on an LED (Light Emission Diode) is presented for stabilizing the conversion gain of the opto-electronic system of a gamma- and fast-neutron radiographic and tomographic imaging device. A constant fraction of the LED light is transported to the image plane of the camera and provides a stable reference exposure. This is used to normalize the images during off…
▽ More
A stable reference light source based on an LED (Light Emission Diode) is presented for stabilizing the conversion gain of the opto-electronic system of a gamma- and fast-neutron radiographic and tomographic imaging device. A constant fraction of the LED light is transported to the image plane of the camera and provides a stable reference exposure. This is used to normalize the images during off-line image processing. We have investigated parameters influencing the stability of LEDs and developed procedures and criteria to prepare and select LEDs suitable for delivering stable light outputs for several 100 h of operation.
△ Less
Submitted 8 February, 2010;
originally announced February 2010.
-
A Dual-Purpose Ion-Accelerator for Nuclear-Reaction-Based Explosives-and SNM-Detection in Massive Cargo
Authors:
M. B. Goldberg,
V. Dangendorf,
D. Vartsky,
D. Bar,
R. Böttger,
M. Brandis,
B. Bromberger,
G. Feldman,
E. Friedman,
D. Heflinger,
R. Lauck,
S. Löb,
P. Maier-Komor,
I. Mardor,
I. Mor,
K. -H. Speidel,
K. Tittelmeier,
M. Weierganz
Abstract:
A dual-purpose ion-accelerator concept, capable of serving as radiation source in a versatile, nuclear-reaction-based cargo inspection system, is presented. The system will automatically and reliably detect small, operationally-relevant quantities of concealed explosives and special nuclear materials (SNM). It will be cost-effective, employing largely-common hardware, but different reactions/DAQ…
▽ More
A dual-purpose ion-accelerator concept, capable of serving as radiation source in a versatile, nuclear-reaction-based cargo inspection system, is presented. The system will automatically and reliably detect small, operationally-relevant quantities of concealed explosives and special nuclear materials (SNM). It will be cost-effective, employing largely-common hardware, but different reactions/DAQ-modes. Typical expected throughput is 10-20 aviation containers/hr.
PACS: 25.20.Dc; 25.40.Ny; 27.20.+n; 29.27.Fh; 79.77.+g; 89.20.Bb; 89.20.Dd
Keywords: Cargo inspection; Nuclear-reaction-based methods; Explosives detection; SNM detection
△ Less
Submitted 19 January, 2010;
originally announced January 2010.
-
High Spatial Resolution Fast-Neutron Imaging Detectors for Pulsed Fast-Neutron Transmission Spectroscopy
Authors:
I. Mor,
D. Vartsky,
D. Bar,
G. Feldman,
M. B. Goldberg,
D. Katz,
E. Sayag,
I. Shmueli,
Y. Cohen,
A. Tal,
Z. Vagish,
B. Bromberger,
V. Dangendorf,
D. Mugai,
K. Tittelmeier,
M. Weierganz
Abstract:
Two generations of a novel detector for high-resolution transmission imaging and spectrometry of fast-neutrons are presented. These devices are based on a hydrogenous fiber scintillator screen and single- or multiple-gated intensified camera systems (ICCD). This detector is designed for energy-selective neutron radiography with nanosecond-pulsed broad-energy (1 - 10 MeV) neutron beams. Utilizing…
▽ More
Two generations of a novel detector for high-resolution transmission imaging and spectrometry of fast-neutrons are presented. These devices are based on a hydrogenous fiber scintillator screen and single- or multiple-gated intensified camera systems (ICCD). This detector is designed for energy-selective neutron radiography with nanosecond-pulsed broad-energy (1 - 10 MeV) neutron beams. Utilizing the Time-of-Flight (TOF) method, such a detector is capable of simultaneously capturing several images, each at a different neutron energy (TOF). In addition, a gamma-ray image can also be simultaneously registered, allowing combined neutron/gamma inspection of objects. This permits combining the sensitivity of the fast-neutron resonance method to low-Z elements with that of gamma radiography to high-Z materials.
△ Less
Submitted 27 May, 2009;
originally announced May 2009.
-
Low-Afterglow, High-Refractive-Index Liquid Scintillators for Fast-Neutron Spectrometry and Imaging Applications
Authors:
Ronald Lauck,
Michal Brandis,
Benjamin Bromberger,
Volker Dangendorf,
Mark B. Goldberg,
Ilan Mor,
Kai Tittelmeier,
David Vartsky
Abstract:
For ion and neutron spectrometry and imaging applications at a high intensity pulsed laser facility, fast liquid scintillators with very low afterglow are required. Furthermore, neutron imaging with fiber (or liquid-core) capillary arrays calls for scintillation materials with high refractive index. To this end, we have examined various combinations of established mixtures of fluors and solvents…
▽ More
For ion and neutron spectrometry and imaging applications at a high intensity pulsed laser facility, fast liquid scintillators with very low afterglow are required. Furthermore, neutron imaging with fiber (or liquid-core) capillary arrays calls for scintillation materials with high refractive index. To this end, we have examined various combinations of established mixtures of fluors and solvents, that were enriched alternatively with nitrogen or oxygen. Dissolved molecular oxygen is known to be a highly effective quenching agent, that efficiently suppresses the population of the triplet states in the fluor, which are primarily responsible for the afterglow. For measuring the glow curves of scintillators, we have employed the time-correlated single photon counting (TCSPC) technique, characterized by high dynamic range of several orders of magnitude in light intensity. In this paper we outline the application for the fast scintillators, briefly present the scintillation mechanism in liquids, describe our specific TCSPC method and discuss the results.
△ Less
Submitted 25 May, 2009;
originally announced May 2009.
-
Multi-Frame Energy-Selective Imaging System for Fast-Neutron Radiography
Authors:
Volker Dangendorf,
Doron Bar,
Benjamin Bromberger,
Gennady Feldman,
Mark B. Goldberg,
Ronald Lauck,
Ilan Mor,
Kai Tittelmeier,
David Vartsky,
Mathias Weierganz
Abstract:
A new instrument for high resolution imaging of fast-neutrons is presented here. It is designed for energy selective radiography in nanosecond-pulsed broad-energy (1 - 10 MeV) neutron beams. The device presented here is based on hydrogenous scintillator screens and single- or multiple-gated intensified camera systems (ICCD). A key element is a newly developed optical amplifier which generates su…
▽ More
A new instrument for high resolution imaging of fast-neutrons is presented here. It is designed for energy selective radiography in nanosecond-pulsed broad-energy (1 - 10 MeV) neutron beams. The device presented here is based on hydrogenous scintillator screens and single- or multiple-gated intensified camera systems (ICCD). A key element is a newly developed optical amplifier which generates sufficient light for the high-speed intensified camera system, even from such faint light sources as fast plastic and liquid scintillators. Utilizing the Time-of-Flight (TOF) method, the detector incorporating the above components is capable of simultaneously taking up to 8 images, each at a different neutron energy.
△ Less
Submitted 25 May, 2009;
originally announced May 2009.
-
THGEM operation in Ne and Ne/CH4
Authors:
M. Cortesi,
V. Peskov,
G. Bartesaghi,
J. Miyamoto,
S. Cohen,
R. Chechik,
J. M. Maia,
J. M. F. dos Santos,
G. Gambarini,
V. Dangendorf,
A. Breskin
Abstract:
The operation of Thick Gaseous Electron Multipliers (THGEM) in Ne and Ne/CH4 mixtures, features high multiplication factors at relatively low operation potentials, in both single- and double-THGEM configurations. We present some systematic data measured with UV-photons and soft x-rays, in various Ne mixtures. It includes gain dependence on hole diameter and gas purity, photoelectron extraction e…
▽ More
The operation of Thick Gaseous Electron Multipliers (THGEM) in Ne and Ne/CH4 mixtures, features high multiplication factors at relatively low operation potentials, in both single- and double-THGEM configurations. We present some systematic data measured with UV-photons and soft x-rays, in various Ne mixtures. It includes gain dependence on hole diameter and gas purity, photoelectron extraction efficiency from CsI photocathodes into the gas, long-term gain stability and pulse rise-time. Position resolution of a 100x100 mm^2 X-rays imaging detector is presented. Possible applications are discussed.
△ Less
Submitted 19 May, 2009; v1 submitted 18 May, 2009;
originally announced May 2009.
-
Signal and Noise Analysis in TRION -Time-Resolved Integrative Optical Fast Neutron Detector
Authors:
D. Vartsky,
G. Feldman,
I. Mor,
M. B. Goldberg,
D. Bar,
V. Dangendorf
Abstract:
TRION is a sub-mm spatial resolution fast neutron imaging detector, which employs an integrative optical time-of-flight technique. The detector was developed for fast neutron resonance radiography, a method capable of detecting a broad range of conventional and improvised explosives. In this study we have analyzed in detail, using Monte-Carlo calculations and experimentally determined parameters…
▽ More
TRION is a sub-mm spatial resolution fast neutron imaging detector, which employs an integrative optical time-of-flight technique. The detector was developed for fast neutron resonance radiography, a method capable of detecting a broad range of conventional and improvised explosives. In this study we have analyzed in detail, using Monte-Carlo calculations and experimentally determined parameters, all the processes that influence the signal and noise in the TRION detector. In contrast to event-counting detectors where the signal-to-noise ratio is dependent only on the number of detected events (quantum noise), in an energy-integrating detector additional factors, such as the fluctuations in imparted energy, number of photoelectrons, system gain and other factors will contribute to the noise. The excess noise factor (over the quantum noise) due to these processes was 4.3, 2.7, 2.1, 1.9 and 1.9 for incident neutron energies of 2, 4, 7.5, 10 and 14 MeV, respectively. It is shown that, even under ideal light collection conditions, a fast neutron detection system operating in an integrative mode cannot be quantum-noise-limited due to the relatively large variance in the imparted proton energy and the resulting scintillation light distributions.
△ Less
Submitted 24 December, 2008;
originally announced December 2008.
-
A concise review on THGEM detectors
Authors:
A. Breskin,
R. Alon,
M. Cortesi,
R. Chechik,
J. Miyamoto,
V. Dangendorf,
J. Maia,
J. M. F. Dos Santos
Abstract:
We briefly review the concept and properties of the Thick GEM (THGEM); it is a robust, high-gain gaseous electron multiplier, manufactured economically by standard printed-circuit drilling and etching technology. Its operation and structure resemble that of GEMs but with 5 to 20-fold expanded dimensions. The millimeter-scale hole-size results in good electron transport and in large avalanche-mul…
▽ More
We briefly review the concept and properties of the Thick GEM (THGEM); it is a robust, high-gain gaseous electron multiplier, manufactured economically by standard printed-circuit drilling and etching technology. Its operation and structure resemble that of GEMs but with 5 to 20-fold expanded dimensions. The millimeter-scale hole-size results in good electron transport and in large avalanche-multiplication factors, e.g. reaching 10^7 in double-THGEM cascaded single-photoelectron detectors. The multiplier's material, parameters and shape can be application-tailored; it can operate practically in any counting gas, including noble gases, over a pressure range spanning from 1 mbar to several bars; its operation at cryogenic (LAr) conditions was recently demonstrated. The high gain, sub-millimeter spatial resolution, high counting-rate capability, good timing properties and the possibility of industrial production capability of large-area robust detectors, pave ways towards a broad spectrum of potential applications; some are discussed here in brief.
△ Less
Submitted 13 July, 2008;
originally announced July 2008.
-
Operation of a Thick Gas Electron Multiplier (THGEM) in Ar, Xe and Ar-Xe
Authors:
R. Alon,
J. Miyamoto,
M. Cortesi,
A. Breskin,
R. Chechik,
I. Carne,
J. M. Maia,
J. M. F. dos Santos,
M. Gai,
D. McKinsey,
V. Dangendorf
Abstract:
We present the results of our recent studies of a Thick Gaseous Electron Multiplier (THGEM)-based detector, operated in Ar, Xe and Ar:Xe (95:5) at various gas pressures. Avalanche-multiplication properties and energy resolution were investigated with soft x-rays for different detector configurations and parameters. Gains above 10E4 were reached in a double-THGEM detector, at atmospheric pressure…
▽ More
We present the results of our recent studies of a Thick Gaseous Electron Multiplier (THGEM)-based detector, operated in Ar, Xe and Ar:Xe (95:5) at various gas pressures. Avalanche-multiplication properties and energy resolution were investigated with soft x-rays for different detector configurations and parameters. Gains above 10E4 were reached in a double-THGEM detector, at atmospheric pressure, in all gases, in almost all the tested conditions; in Ar:Xe (95:5) similar gains were reached at pressures up to 2 bar. The energy resolution dependence on the gas, pressure, hole geometry and electric fields was studied in detail, yielding in some configurations values below 20% FWHM with 5.9 keV x-rays.
△ Less
Submitted 26 December, 2007; v1 submitted 4 December, 2007;
originally announced December 2007.
-
Investigations of a THGEM-based imaging detector
Authors:
M. Cortesi,
R. Alon,
R. Chechik,
A. Breskin,
D. Vartsky,
V. Dangendorf
Abstract:
We present the results of our recent studies on a Thick Gas Electron Multiplier (THGEM)-based imaging detector prototype. It consists of two 100x100 mm^2 THGEM electrodes in cascade, coupled to a resistive anode. The event location is recorded with a 2D double-sided readout electrode equipped with discrete delay-lines and dedicated electronics. The THGEM electrodes, produced by standard printed-…
▽ More
We present the results of our recent studies on a Thick Gas Electron Multiplier (THGEM)-based imaging detector prototype. It consists of two 100x100 mm^2 THGEM electrodes in cascade, coupled to a resistive anode. The event location is recorded with a 2D double-sided readout electrode equipped with discrete delay-lines and dedicated electronics. The THGEM electrodes, produced by standard printed-circuit board and mechanical drilling techniques, a 0.4 mm thick with 0.5 mm diameter holes spaced by 1 mm. Localization resolutions of about 0.7 mm (FWHM) were measured with soft x-rays, in a detector operated with atmospheric-pressure Ar/CH4; good linearity and homogeneity were achieved. We describe the imaging-detector layout, the resistive-anode 2D readout system and the imaging properties. The THGEM has numerous potential applications that require large-area imaging detectors, with high-rate capability, single-electron sensitivity and moderate (sub-mm) localization resolution.
△ Less
Submitted 26 December, 2007; v1 submitted 22 July, 2007;
originally announced July 2007.
-
A Compact High-Energy Neutron Spectrometer
Authors:
F. D. Brooks,
A. Buffler,
M. S. Allie,
M. S. Herbert,
M. R. Nchodu,
D. T. L. Jones,
F. D. Smit,
R. Nolte,
V. Dangendorf
Abstract:
A compact liquid organic neutron spectrometer (CLONS) based on a single NE213 liquid scintillator (5 cm diam. x 5 cm) is described. The spectrometer is designed to measure neutron fluence spectra over the energy range 2-200 MeV and is suitable for use in neutron fields having any type of time structure. Neutron fluence spectra are obtained from measurements of two-parameter distributions (counts…
▽ More
A compact liquid organic neutron spectrometer (CLONS) based on a single NE213 liquid scintillator (5 cm diam. x 5 cm) is described. The spectrometer is designed to measure neutron fluence spectra over the energy range 2-200 MeV and is suitable for use in neutron fields having any type of time structure. Neutron fluence spectra are obtained from measurements of two-parameter distributions (counts versus pulse height and pulse shape) using the Bayesian unfolding code MAXED. Calibration and test measurements made using a pulsed neutron beam with a continuous energy spectrum are described and the application of the spectrometer to radiation dose measurements is discussed.
△ Less
Submitted 23 March, 2007;
originally announced March 2007.
-
A position- and time-sensitive photon-counting detector with delay-line read-out
Authors:
O. Jagutzki,
V. Dangendorf,
R. Lauck,
A. Czasch,
J. Milnes
Abstract:
We have developed image intensifier tubes with delay-anode read-out for time- and position-sensitive photon counting. The timing precision is better than 1 ns with 1000x1000 pixels position resolution and up to one megacounts/s processing rate. Large format detectors of 40 and 75 mm active diameter with internal helical-wire delay-line anodes have been produced and specified. A different type of…
▽ More
We have developed image intensifier tubes with delay-anode read-out for time- and position-sensitive photon counting. The timing precision is better than 1 ns with 1000x1000 pixels position resolution and up to one megacounts/s processing rate. Large format detectors of 40 and 75 mm active diameter with internal helical-wire delay-line anodes have been produced and specified. A different type of 40 and 25 mm tubes with semi-conducting screen for image charge read-out allow for an economic and robust tube design and for placing the read-out anodes outside the sealed housing. Two types of external delay-line anodes, i.e. pick-up electrodes for the image charge, have been tested. We present tests of the detector and anode performance. Due to the low background this technique is well suited for applications with very low light intensity and especially if a precise time tagging for each photon is required. As an example we present the application of scintillator read-out in time-of-flight (TOF) neutron radiography. Further applications so far are Fluorescence Life-time Microscopy (FLIM) and Astronomy
△ Less
Submitted 19 March, 2007;
originally announced March 2007.
-
Neutron imaging with a Micromegas detector
Authors:
F. Jeanneau,
R. Junca,
J. Pancin,
M. Voytchev,
S. Andriamonje,
V. Dangendorf,
I. Espagnon,
H. Friedrich,
A. Giganon,
I. Giomataris,
A. Menelle,
A. Pluquet,
L. R. Rodriguez
Abstract:
The micropattern gaseous detector Micromegas has been developed for several years in Saclay and presents good performance for neutron detection. A prototype for neutron imaging has been designed and new results obtained in thermal neutron beams are presented. Based on previous results demonstrating a good 1D spatial resolution, a tomographic image of a multiwire cable has been performed using a…
▽ More
The micropattern gaseous detector Micromegas has been developed for several years in Saclay and presents good performance for neutron detection. A prototype for neutron imaging has been designed and new results obtained in thermal neutron beams are presented. Based on previous results demonstrating a good 1D spatial resolution, a tomographic image of a multiwire cable has been performed using a 1D Micromegas prototype. The number of pillars supporting the micromesh is too large and leads to local losses of efficiency that distort the tomographic reconstruction. Nevertheless, this first tomographic image achieved with this kind of detector is very encouraging. The next worthwhile development for neutron imaging is to achieve a bi-dimensional detector, which is presented in the second part of this study. The purpose of measurements was to investigate various operational parameters to optimize the spatial resolution. Through these measurements the optimum spatial resolution has been found to be around 160 microns (standard deviation) using Micromegas operating in double amplification mode. Several 2D imaging tests have been carried out. Some of these results have revealed fabrication defects that occurred during the manufacture of Micromegas and that are limiting the full potential of the present neutron imaging system.
△ Less
Submitted 21 July, 2006;
originally announced July 2006.
-
Advances in imaging THGEM-based detectors
Authors:
M. Cortesi,
R. Chechik,
A. Breskin,
G. Guedes,
V. Dangendorf,
D. Vartzky,
D. Bar
Abstract:
The thick GEM (THGEM) [1] is an "expanded" GEM, economically produced in the PCB industry by simple drilling and etching in G-10 or other insulating materials (fig. 1). Similar to GEM, its operation is based on electron gas avalanche multiplication in sub-mm holes, resulting in very high gain and fast signals. Due to its large hole size, the THGEM is particularly efficient in transporting the el…
▽ More
The thick GEM (THGEM) [1] is an "expanded" GEM, economically produced in the PCB industry by simple drilling and etching in G-10 or other insulating materials (fig. 1). Similar to GEM, its operation is based on electron gas avalanche multiplication in sub-mm holes, resulting in very high gain and fast signals. Due to its large hole size, the THGEM is particularly efficient in transporting the electrons into and from the holes, leading to efficient single-electron detection and effective cascaded operation. The THGEM provides true pixilated radiation localization, ns signals, high gain and high rate capability. For a comprehensive summary of the THGEM properties, the reader is referred to [2, 3]. In this article we present a summary of our recent study on THGEM-based imaging, carried out with a 10x10 cm^2 double-THGEM detector.
△ Less
Submitted 25 June, 2006;
originally announced June 2006.
-
Thick GEM-like (THGEM) detectors and their possible applications
Authors:
R. Chechik,
M. Cortesi,
A. Breskin,
D. Vartsky,
D. Bar,
V. Dangendorf
Abstract:
Thick GEM-like (THGEM) electrodes are robust, high gain gaseous electron multipliers, economically-manufactured by standard drilling and etching of thin printed circuit board or other materials. Their operation and structure are similar to that of standard GEMs but with 5 to 20-fold expanded dimensions. Due to the larger hole dimensions they provide up to 10^5 and 10^7 charge multiplication, in…
▽ More
Thick GEM-like (THGEM) electrodes are robust, high gain gaseous electron multipliers, economically-manufactured by standard drilling and etching of thin printed circuit board or other materials. Their operation and structure are similar to that of standard GEMs but with 5 to 20-fold expanded dimensions. Due to the larger hole dimensions they provide up to 10^5 and 10^7 charge multiplication, in a single- and in two-electrode cascade, respectively. The signal rise time is of a few ns and the counting-rate capability approaches 10 MHz/mm^2 at 10^4 gains. Sub-mm localization precision was demonstrated with a simple, delay-line based 2D readout scheme. These multipliers may be produced in a variety of shapes and sizes and can operate in many gases. They may replace the standard GEMs in many applications requiring very large area, robust, flat, thin detectors, with good timing and counting-rate properties and modest localization. The properties of these multipliers are presented in short and possible applications are discussed.
△ Less
Submitted 18 June, 2006;
originally announced June 2006.
-
Amplification and Scintillation Properties of Oxygen-Rich Gas Mixtures for Optical-TPC Applications
Authors:
L. Weissman,
M. Gai,
A. Breskin,
R. Chechik,
V. Dangendorf,
K. Tittelmeier,
H. R. Weller
Abstract:
We studied electron amplification and light emission from avalanches in oxygen-containing gas mixtures. The mixtures investigated in this work included, among others, CO2 and N2O mixed with Triethylamine (TEA) or N2. Double-Step Parallel Gap (DSPG) multipliers and THick Gas Electron Multipliers (THGEM) were investigated. High light yields were measured from CO2+N2 and CO2+TEA, though with differ…
▽ More
We studied electron amplification and light emission from avalanches in oxygen-containing gas mixtures. The mixtures investigated in this work included, among others, CO2 and N2O mixed with Triethylamine (TEA) or N2. Double-Step Parallel Gap (DSPG) multipliers and THick Gas Electron Multipliers (THGEM) were investigated. High light yields were measured from CO2+N2 and CO2+TEA, though with different emission spectra. We observed the characteristic wave-length emission of N2 and of TEA and used a polymer wave-length shifter to convert TEA UV-light into the visible spectrum. The results of these measurements indicate the applicability of optical recording of ionizing tracks in a TPC target-detector designed to study the cross section of the 16O(g,a)12C reaction, a central problem in nuclear astrophysics.
△ Less
Submitted 27 May, 2006; v1 submitted 27 February, 2006;
originally announced February 2006.
-
Optical Readout Time Projection Chamber (O-TPC) for a Study of Oxygen Formation In Stellar Helium Burning
Authors:
Moshe Gai,
Amos Breskin,
Rachel Chechik,
Volker Dangendorf,
Henry R. Weller
Abstract:
We are develo** an Optical Readout Time Projection Chamber (O-TPC) detector for the study of the 12C(a,g)16O reaction that determines the ratio of carbon to oxygen in helium burning. This ratio is crucial for understanding the final fate of a progenitor star and the nucleosynthesis of elements prior to a Type II supernova; an oxygen rich star is predicted to collapse to a black hole, and a car…
▽ More
We are develo** an Optical Readout Time Projection Chamber (O-TPC) detector for the study of the 12C(a,g)16O reaction that determines the ratio of carbon to oxygen in helium burning. This ratio is crucial for understanding the final fate of a progenitor star and the nucleosynthesis of elements prior to a Type II supernova; an oxygen rich star is predicted to collapse to a black hole, and a carbon rich star to a neutron star. Type Ia supernovae (SNeIa) are used as standard candles for measuring cosmological distances with the use of an empirical light curve-luminosity stretching factor. It is essential to understand helium burning that yields the carbon/oxygen white dwarf and thus the initial stage of SNeIa. The O-TPC is intended for use with high intensity photon beams extracted from the HIgS/TUNL facility at Duke University to study the 16O(g,a)12C reaction, and thus the direct reaction at energies as low as 0.7 MeV. We are conducting a systematical study of the best oxygen containing gas with light emitting admixture(s) for use in such an O-TPC. Preliminary results with CO_2 + TEA mixture were obtained
△ Less
Submitted 1 April, 2005;
originally announced April 2005.
-
Development and application of an optical TPC for charged particle track structure imaging in microdosimetry
Authors:
U. Titt,
V. Dangendorf,
B. Grosswendt,
H. Schuhmacher
Abstract:
An imaging system for measuring the track structure of charged particles in a low-pressure gas is presented. We describe the experimental method and compare experimental results with first results of a simulation of the chamber response.
An imaging system for measuring the track structure of charged particles in a low-pressure gas is presented. We describe the experimental method and compare experimental results with first results of a simulation of the chamber response.
△ Less
Submitted 27 October, 2004;
originally announced October 2004.
-
Imaging of microscopic features of charged-particle tracks in a low-pressure gas
Authors:
V. Dangendorf,
H. Schuhmacher,
U. Titt,
K. Tittelmeier
Abstract:
An imaging system for measuring the spatial distribtion of charged particle tracks in a low-pressure gas is presented. The method is based on an optically read out time projection chamber. Results of experiments with fast heavy ions are shown.
An imaging system for measuring the spatial distribtion of charged particle tracks in a low-pressure gas is presented. The method is based on an optically read out time projection chamber. Results of experiments with fast heavy ions are shown.
△ Less
Submitted 27 October, 2004;
originally announced October 2004.
-
Digital imaging of charged particle track structures with a low-pressure optical time projection chamber
Authors:
U. Titt,
V. Dangendorf,
H. Schuhmacher
Abstract:
We describe first results obtained with a track structure imaging system for measuring the ionisation topology of charged particles in a low-pressure gas. The detection method is based on a time projection chamber (TPC) filled with low-pressure triethylamine (TEA). Images of ionisation tracks of electrons, protons, and heavier ions are presented and analysed.
We describe first results obtained with a track structure imaging system for measuring the ionisation topology of charged particles in a low-pressure gas. The detection method is based on a time projection chamber (TPC) filled with low-pressure triethylamine (TEA). Images of ionisation tracks of electrons, protons, and heavier ions are presented and analysed.
△ Less
Submitted 27 October, 2004;
originally announced October 2004.
-
A time projection chamber with optical readout for charged particle track structure imaging
Authors:
U. Titt,
A. Breskin,
R. Chechik,
V. Dangendorf,
H. Schmidt-Boecking,
H. Schuhmacher
Abstract:
We report about a nuclear track imaging system which is designed to study in detail the ionization topology of charged particle tracks in a low-pressure gas. The detection method is based on a time projection chamber (TPC) filled with low-pressure triethylamine (TEA). Ionization electrons produced by energetic charged particles are three-dimensionally imaged by recording light from electron aval…
▽ More
We report about a nuclear track imaging system which is designed to study in detail the ionization topology of charged particle tracks in a low-pressure gas. The detection method is based on a time projection chamber (TPC) filled with low-pressure triethylamine (TEA). Ionization electrons produced by energetic charged particles are three-dimensionally imaged by recording light from electron avalanches with an intensified CCD system. The detector permits to inves-tigate the spatial ionization distributions of particle tracks in gas, of equivalent length and resolution in tissue of 4 mm and 40 nm (RMS), respectively. We explain the relevance of this technique for dosimetry, describe the experimental method and the basic operation parameters. First results of the chamber response to protons and alpha particles are presented.
△ Less
Submitted 27 October, 2004;
originally announced October 2004.
-
Time-resolved fast neutron imaging: simulation of detector performance
Authors:
D. Vartsky,
I. Mor,
M. B. Goldberg,
I. Mardor,
G. Feldman,
D. Bar,
A. Shor,
V. Dangendorf,
G. Laczko,
A. Breskin,
R. Chechik
Abstract:
We have analyzed and compared the performance of two novel fast-neutron imaging methods with time-of-flight spectroscopy capability. Using MCNP and GEANT code simulations of neutron and charged-particle transport in the detectors, key parameters such as detection efficiency, the amount of energy deposited in the converter and the spatial resolution of both detector variants have been evaluated.
We have analyzed and compared the performance of two novel fast-neutron imaging methods with time-of-flight spectroscopy capability. Using MCNP and GEANT code simulations of neutron and charged-particle transport in the detectors, key parameters such as detection efficiency, the amount of energy deposited in the converter and the spatial resolution of both detector variants have been evaluated.
△ Less
Submitted 17 August, 2004;
originally announced August 2004.
-
Detectors for Time-of-Flight Fast-Neutron Radiography: 1. Neutron Counting Gas Detector
Authors:
V. Dangendorf,
A. Breskin,
R. Chechik,
M. Goldberg,
G. Laczko,
I. Mor,
M. Reginatto,
D. Vartsky
Abstract:
One of our two methods for fast-neutron imaging with spectrometric capability is presented here. It is a neutron-counting technique based on a hydrogenous neutron converter coupled to Gaseous Electron Multipliers (GEM). The principles of the detection techniques and the optimization of the converter, electron amplification and the readout are described. Evaluation of the properties are derived f…
▽ More
One of our two methods for fast-neutron imaging with spectrometric capability is presented here. It is a neutron-counting technique based on a hydrogenous neutron converter coupled to Gaseous Electron Multipliers (GEM). The principles of the detection techniques and the optimization of the converter, electron amplification and the readout are described. Evaluation of the properties are derived from a experiment in a pulsed neutron beam of spectral distribution between 2 and 10 MeV
△ Less
Submitted 17 August, 2004;
originally announced August 2004.
-
Detectors for Energy-Resolved Fast Neutron Imaging
Authors:
V. Dangendorf,
A. Breskin,
R. Chechik,
G. Feldman,
M. B. Goldberg,
O. Jagutzki,
C. Kersten,
G. Laczko,
I. Mor,
U. Spillman,
D. Vartsky
Abstract:
Two detectors for energy-resolved fast-neutron imaging in pulsed broad-energy neutron beams are presented. The first one is a neutron-counting detector based on a solid neutron converter coupled to a gaseous electron multiplier (GEM). The second is an integrating imaging technique, based on a scintillator for neutron conversion and an optical imaging system with fast framing capability.
Two detectors for energy-resolved fast-neutron imaging in pulsed broad-energy neutron beams are presented. The first one is a neutron-counting detector based on a solid neutron converter coupled to a gaseous electron multiplier (GEM). The second is an integrating imaging technique, based on a scintillator for neutron conversion and an optical imaging system with fast framing capability.
△ Less
Submitted 25 March, 2004;
originally announced March 2004.
-
Recent Investigations of Cascaded GEM and MHSP detectors
Authors:
R. Chechik,
A. Breskin,
G. P. Guedes,
D. Moermann,
J. Maia,
V. Dangendorf,
D. Vartzky,
J. M. F. Dos Santos,
J. F. C. A. Veloso
Abstract:
We present results from our recent investigations on detectors comprising cascaded gas electron multipliers (GEM) and cascaded GEMs with micro-hole and strip (MHSP) electrodes. We discuss the factors governing the operation of these fast radiation imaging detectors, that have single-charge sensitivity. The issue of ion-backflow and ion-induced secondary effects is discussed in some detail, prese…
▽ More
We present results from our recent investigations on detectors comprising cascaded gas electron multipliers (GEM) and cascaded GEMs with micro-hole and strip (MHSP) electrodes. We discuss the factors governing the operation of these fast radiation imaging detectors, that have single-charge sensitivity. The issue of ion-backflow and ion-induced secondary effects is discussed in some detail, presenting ways for its reduction and suppression. Applications are presented in the fields of photon imaging in the UV-to-visible spectral range as well as x-ray and neutron imaging.
△ Less
Submitted 24 November, 2003;
originally announced November 2003.
-
High Resolution Heavy Ion Track Structure Imaging
Authors:
G. Laczko,
V. Dangendorf,
M. Kraemer,
D. Schardt,
K. Tittelmeier
Abstract:
The difference in the relative biological efficincy (RBE) of ions of same linear energy transfer (LET) but different atomic number (Z) can be attributed to the difference in the radial ionisation distribution. In this contribution we present data from measurements of the spatial ionisation pattern of heavy ions of various Z but similar LET and compare the results with track structure data obtain…
▽ More
The difference in the relative biological efficincy (RBE) of ions of same linear energy transfer (LET) but different atomic number (Z) can be attributed to the difference in the radial ionisation distribution. In this contribution we present data from measurements of the spatial ionisation pattern of heavy ions of various Z but similar LET and compare the results with track structure data obtained by Monte Carlo simulations. The measurements were made with a time projection chamber with optical readout (Optical Avalanche Chamber, OPAC) which is able to quantitatively capture the spatial ionisation pattern of an ion traversing the chamber
△ Less
Submitted 17 October, 2003;
originally announced October 2003.
-
Fast Neutron Resonance Radiography in a Pulsed Neutron Beam
Authors:
V. Dangendorf,
G. Laczko,
C. Kersten,
O. Jagutzki,
U. Spillmann
Abstract:
The feasibility of performing fast neutron resonance radiography at the PTB accelerator facility is studied. A neutron beam of a broad spectral distribution is produced by a pulsed 13 MeV deuterium beam hitting a thick Be target. The potential of 3 different neutron imaging detectors with time-of flight capability are investigated. The applied methods comprise wire chambers with hydrogenous conv…
▽ More
The feasibility of performing fast neutron resonance radiography at the PTB accelerator facility is studied. A neutron beam of a broad spectral distribution is produced by a pulsed 13 MeV deuterium beam hitting a thick Be target. The potential of 3 different neutron imaging detectors with time-of flight capability are investigated. The applied methods comprise wire chambers with hydrogenous converter layers and a fast plastic scintillator with different optical readout schemes. We present the neutron facility, the imaging methods employed and results obtained. in beam experiments where samples of carbon rods with various length and diameter were imaged to study resolution and sensitivity of the method.
△ Less
Submitted 2 January, 2003;
originally announced January 2003.