-
Atomic number estimation of dual energy cargo radiographs using a semiempirical transparency model
Authors:
Peter Lalor,
Areg Danagoulian
Abstract:
Dual energy cargo inspection systems are sensitive to both the area density and the atomic number of an imaged container due to the $Z$ dependence of photon attenuation. The ability to identify cargo contents by their atomic number enables improved detection capabilities of illicit materials. This work introduces a novel method for atomic number reconstruction by minimizing the chi-squared error b…
▽ More
Dual energy cargo inspection systems are sensitive to both the area density and the atomic number of an imaged container due to the $Z$ dependence of photon attenuation. The ability to identify cargo contents by their atomic number enables improved detection capabilities of illicit materials. This work introduces a novel method for atomic number reconstruction by minimizing the chi-squared error between measured transparency values and a semiempirical transparency model. This method is tested using two Geant4 Monte Carlo simulated radiographic phantoms, demonstrating the ability to obtain accurate material predictions on noisy input images, even in the presence of shielding. Furthermore, we provide a simple procedure for porting this method to a commercial system, requiring an approximate model of the scanner's beam spectra and detector response, along with only three calibration measurements.
△ Less
Submitted 21 February, 2024; v1 submitted 22 July, 2023;
originally announced July 2023.
-
A Semiempirical Transparency Model for Dual Energy Cargo Radiography Applications
Authors:
Peter Lalor,
Areg Danagoulian
Abstract:
Cargo containers passing through ports are scanned by non-intrusive inspection systems to search for concealed illicit materials. By using two photon beams with different energy spectra, dual energy inspection systems are sensitive to both the area density and the atomic number of cargo contents. Most literature on the subject assumes a simple exponential attenuation model for photon intensity in…
▽ More
Cargo containers passing through ports are scanned by non-intrusive inspection systems to search for concealed illicit materials. By using two photon beams with different energy spectra, dual energy inspection systems are sensitive to both the area density and the atomic number of cargo contents. Most literature on the subject assumes a simple exponential attenuation model for photon intensity in which only free streaming photons are detected. However, this approximation neglects second order effects such as scattering, leading to a biased model and thus incorrect material predictions. This work studies the accuracy of the free streaming model by comparing it to simulation outputs, finding that the model shows poor atomic number reconstruction accuracy at high-$Z$ and suffers significantly if the source energy spectra and detector response function are not known exactly. To address these challenges, this work introduces a semiempirical transparency model which modifies the free streaming model by rescaling different components of the mass attenuation coefficient, allowing the model to capture secondary effects ignored by the free streaming model. The semiempirical model displays improvement agreement with simulated results at high-$Z$ and shows excellent extrapolation to materials and thicknesses which were not included during the calibration step. Furthermore, this work demonstrates that the semiempirical model yields accurate atomic number predictions even when the source spectra and detector response are not known exactly. Using the semiempirical model, manufacturers can perform a simple calibration to enable more precise $Z$ reconstruction capabilities, which has the potential to significantly improve the performance of existing radiographic systems.
△ Less
Submitted 14 February, 2023;
originally announced February 2023.
-
Fundamental limitations of dual energy X-ray scanners for cargo content atomic number discrimination
Authors:
Peter Lalor,
Areg Danagoulian
Abstract:
To combat the risk of nuclear smuggling, radiography systems are deployed at ports to scan cargo containers for concealed illicit materials. Dual energy radiography systems enable a rough elemental analysis of cargo containers due to the $Z$-dependence of photon attenuation, allowing for improved material detection. This work studies the capabilities for atomic number discrimination using dual ene…
▽ More
To combat the risk of nuclear smuggling, radiography systems are deployed at ports to scan cargo containers for concealed illicit materials. Dual energy radiography systems enable a rough elemental analysis of cargo containers due to the $Z$-dependence of photon attenuation, allowing for improved material detection. This work studies the capabilities for atomic number discrimination using dual energy MeV systems by considering dual energy $\{6, 4\}$ MeV, $\{10, 6\}$ MeV, and $\{10, 4\}$ MeV bremsstrahlung beams. Results of this analysis show that two different pure materials can sometimes produce identical transparency measurements, leading to a fundamental ambiguity when differentiating between materials of different atomic numbers. Previous literature has observed this property, but the extent of the limitation is poorly understood and the cause of the degeneracy is generally inadequately explained. This non-uniqueness property stems from competition between photoelectric absorption and pair production and is present even in systems with perfect resolution and zero statistical noise. These findings are validated through Monte Carlo transparency simulations. Results of this study show that currently deployed commercial radiographic systems are fundamentally incapable of distinguishing between high-$Z$ nuclear materials and miscellaneous mid-$Z$ cargo contents.
△ Less
Submitted 24 January, 2024; v1 submitted 13 January, 2023;
originally announced January 2023.
-
Neutron Resonance Transmission Analysis with a Compact Deuterium-Tritium Neutron Generator
Authors:
Ethan A. Klein,
Farheen Naqvi,
Jacob E. Bickus,
Hin Y. Lee,
Robert J. Goldston,
Areg Danagoulian
Abstract:
Neutron Resonance Transmission Analysis (NRTA) is a spectroscopic technique which uses the resonant absorption of neutrons in the epithermal range to infer the isotopic composition of an object. This spectroscopic technique has relevance in many traditional fields of science and nuclear security. NRTA in the past made use of large, expensive accelerator facilities to achieve precise neutron beams,…
▽ More
Neutron Resonance Transmission Analysis (NRTA) is a spectroscopic technique which uses the resonant absorption of neutrons in the epithermal range to infer the isotopic composition of an object. This spectroscopic technique has relevance in many traditional fields of science and nuclear security. NRTA in the past made use of large, expensive accelerator facilities to achieve precise neutron beams, significantly limiting its applicability. In this work we describe a series of NRTA experiments where we use a compact, low-cost deuterium-tritium (DT) neutron generator to produce short neutron beams (2.6~m) along with a $^6$Li-glass neutron detector. The time-of-flight spectral data from five elements -- silver, cadmium, tungsten, indium, and $^{238}$U -- clearly show the corresponding absorption lines in the 1-30 eV range. The experiments show the applicability of NRTA in this simplified configuration, and prove the feasibility of this compact and low-cost approach. This could significantly broaden the applicability of NRTA, and make it practical and applicable in many fields, such as material science, nuclear engineering, and arms control.
△ Less
Submitted 16 April, 2021; v1 submitted 5 December, 2020;
originally announced December 2020.
-
An accelerator facility for intermediate energy proton irradiation and testing of nuclear materials
Authors:
S. J. Jepeal,
A. Danagoulian,
L. A. Kesler,
D. A. Korsun,
H. Y. Lee,
N. Schwartz,
B. N. Sorbom,
E. Velez Lopez,
Z. S. Hartwig
Abstract:
The bulk irradiation of materials with 10-30 MeV protons promises to advance the study of radiation damage for fission and fusion power plants. Intermediate energy proton beams can now be dedicated to materials irradiation within university-scale laboratories. This paper describes the first such facility, with an Ionetix ION-12SC cyclotron producing 12 MeV proton beams. Samples are mm-scale tensil…
▽ More
The bulk irradiation of materials with 10-30 MeV protons promises to advance the study of radiation damage for fission and fusion power plants. Intermediate energy proton beams can now be dedicated to materials irradiation within university-scale laboratories. This paper describes the first such facility, with an Ionetix ION-12SC cyclotron producing 12 MeV proton beams. Samples are mm-scale tensile specimens with thicknesses up to 300 um, mounted to a cooled beam target with control over temperature. A specialized tensile tester for radioactive specimens at high temperature (500+ °C) and/or vacuum represents the conditions in fission and fusion systems, while a digital image correlation system remotely measures strain. Overall, the facility provides university-scale irradiation and testing capability with intermediate energy protons to complement traditional in-core fission reactor and micro-scale ion irradiation. This facility demonstrates that bulk proton irradiation is a scalable and effective approach for nuclear materials research, down-selection, and qualification.
△ Less
Submitted 20 November, 2020; v1 submitted 12 October, 2020;
originally announced October 2020.
-
Multiple Monoenergetic Gamma Radiography (MMGR) with a compact superconducting cyclotron
Authors:
Hin Y. Lee,
Brian S. Henderson,
Roberts G. Nelson,
Areg Danagoulian
Abstract:
Smuggling of special nuclear materials (SNM) and nuclear devices through borders and ports of entry constitutes a major risk to global security. Technologies are needed to reliably screen the flow of commerce for the presence of high-$Z$ materials such as uranium and plutonium. Here we present an experimental proof-of-concept of a technique which uses inelastic ($p,p'$) nuclear reactions to genera…
▽ More
Smuggling of special nuclear materials (SNM) and nuclear devices through borders and ports of entry constitutes a major risk to global security. Technologies are needed to reliably screen the flow of commerce for the presence of high-$Z$ materials such as uranium and plutonium. Here we present an experimental proof-of-concept of a technique which uses inelastic ($p,p'$) nuclear reactions to generate monoenergetic photons, which provide means to measure the areal density and the effective-$Z$ ($Z_{\text{eff}}$) of an object with an accuracy which surpasses that achieved by current methods. We use an ION-12$^{ \text{SC}}$ superconducting 12~MeV proton cyclotron to produce 4.4, 6.1, 6.9, and 7.1~MeV photons from a variety of nuclear reactions. Using these photons in a transmission mode we show that we are able to accurately reconstruct the areal densities and $Z_{\text{eff}}$ of a test object. This methodology could enable mobile applications to screen commercial cargoes with high material specificity, providing a means of distinguishing common cargo materials from high-Z materials that include uranium and plutonium.
△ Less
Submitted 22 August, 2020; v1 submitted 27 November, 2019;
originally announced November 2019.
-
Feasibility study of a compact Neutron Resonance Transmission Analysis instrument
Authors:
Ezra M. Engel,
Ethan A. Klein,
Areg Danagoulian
Abstract:
Neutron Resonance Transmission Analysis (NRTA) uses resonant absorption of neutrons to infer the absolute isotopic composition of a target object, enabling applications in a broad range of fields such as archaeology, materials analysis of nuclear fuel, and arms control treaty verification. In the past, NRTA involved large user facilities and complex detector systems. However, recent advances in th…
▽ More
Neutron Resonance Transmission Analysis (NRTA) uses resonant absorption of neutrons to infer the absolute isotopic composition of a target object, enabling applications in a broad range of fields such as archaeology, materials analysis of nuclear fuel, and arms control treaty verification. In the past, NRTA involved large user facilities and complex detector systems. However, recent advances in the intensity of compact neutron sources have made compact neutron imaging designs increasingly feasible. This work describes the Monte Carlo (MC) based design of a compact epithermal NRTA radiographic instrument which uses a moderated, compact deuterium-tritium (DT) neutron source and an epithermal neutron detector. Such an instrument would have a wide range of applications, and would be especially impactful for such scenarios as nuclear inspection and arms control verification exercises, where system cost and mobility may be of critical importance. The MC simulations presented in this work demonstrate accurate time-of-flight (TOF) reconstructions for transmitted neutron energies, capable of differentiating isotopic compositions of nuclear material with high levels of accuracy. A new generation of miniaturized and increasingly more intense neutron sources will allow this technique to achieve measurements with greater precision and speed, with significant impact on a variety of engineering and societal problems.
△ Less
Submitted 28 January, 2020; v1 submitted 24 September, 2019;
originally announced September 2019.
-
Hydrogenous content identification in heterogeneous cargoes via multiple monoenergetic neutron radiography
Authors:
Jill Rahon,
Areg Danagoulian
Abstract:
The determination of hydrogenous content in commercial cargoes is an important challenge in cargo security. Prior work has shown the feasibility of hydrogenous cargo classification in radiographic applications. This result was achieved by using the significant material to material differences in the energy dependence of their neutron scattering cross-sections. The work presented here details the a…
▽ More
The determination of hydrogenous content in commercial cargoes is an important challenge in cargo security. Prior work has shown the feasibility of hydrogenous cargo classification in radiographic applications. This result was achieved by using the significant material to material differences in the energy dependence of their neutron scattering cross-sections. The work presented here details the application of this technique to multiple-monoenergetic neutron transmission measurements of several heterogeneous cargo mock-ups with the goal of quantifying hydrogenous content. It demonstrates the ability to determine the hydrogenous content of a cargo container by performing analysis of pulse-height data of transmitted neutrons. The set-up used for these feasibility studies was able to detect and quantify areal densities of up to 30 g/cm$^2$ of high density polyethylene (HDPE), even when mixed with metallic materials. Accurate determination of the hydrogenous content of the cargo has two important uses: it can allow for better imaging and discrimination of conventional contraband during cargo screening; it may also allow the unfolding of the individual elemental contributions from an effective atomic number, $Z_{\mathrm{eff}}$, as determined from multiple monoenergetic gamma radiography (MMGR). This combination of capabilities could make multiple monoenergetic neutron radiography applications a significant contribution to cargo security.
△ Less
Submitted 15 September, 2019;
originally announced September 2019.
-
A physically cryptographic warhead verification system using neutron induced nuclear resonances
Authors:
Ezra M. Engel,
Areg Danagoulian
Abstract:
Arms control treaties are necessary to reduce the large stockpiles of the nuclear weapons that constitute one of the biggest dangers to the world. However, an impactful treaty hinges on effective inspection exercises to verify the participants' compliance to the treaty terms. Such procedures would require verification of the authenticity of a warhead undergoing dismantlement. Previously proposed s…
▽ More
Arms control treaties are necessary to reduce the large stockpiles of the nuclear weapons that constitute one of the biggest dangers to the world. However, an impactful treaty hinges on effective inspection exercises to verify the participants' compliance to the treaty terms. Such procedures would require verification of the authenticity of a warhead undergoing dismantlement. Previously proposed solutions lacked the combination of isotopic sensitivity and information security. Here we present the experimental feasibility proof of a novel technique that uses neutron induced nuclear resonances and is sensitive to the combination of isotopics and geometry. The information is physically encrypted to prevent the leakage of sensitive information. Our approach can significantly increase the trustworthiness of future arms control treaties while expanding their scope to include the verified dismantlement of nuclear warheads themselves.
△ Less
Submitted 1 October, 2019; v1 submitted 2 July, 2019;
originally announced July 2019.
-
Fissile material detection using neutron time-correlations from photofission
Authors:
R. A. Soltz,
A. Danagoulian,
E. P. Hartouni,
M. S. Johnson,
S. A. Sheets,
A. Glenn,
S. E. Korbly,
R. J. Ledoux
Abstract:
The detection of special nuclear materials (SNM) in commercial cargoes is a major objective in the field of nuclear security. In this work we investigate the use of two-neutron time-correlations from photo-fission using the Prompt Neutrons from Photofission (PNPF) detectors in Passport Systems Inc.'s (PSI) Shielded Nuclear Alarm Resolution (SNAR) platform~\cite{pnpf} for the purpose of detecting…
▽ More
The detection of special nuclear materials (SNM) in commercial cargoes is a major objective in the field of nuclear security. In this work we investigate the use of two-neutron time-correlations from photo-fission using the Prompt Neutrons from Photofission (PNPF) detectors in Passport Systems Inc.'s (PSI) Shielded Nuclear Alarm Resolution (SNAR) platform~\cite{pnpf} for the purpose of detecting $\sim$5~kg quantities of fissionable materials in seconds. The goal of this effort was to extend the secondary scan mode of this system to differentiate fissile materials, such as highly enriched uranium, from fissionable materials, such as low enriched and depleted uranium (LEU and DU). Experiments were performed using a variety of material samples, and data were analyzed using the variance-over-mean technique referred to as $Y_{2F}$ or Feynman-$α$. Results were compared to computational models to improve our ability to predict system performance for distinguishing fissile materials. Simulations were then combined with empirical formulas to generate receiver operating characteristics (ROC) curves for a variety of shielding scenarios. We show that a 10 second screening with a 200~$μ$A 9~MeV X-ray beam is sufficient to differentiate kilogram quantities of HEU from DU in various shielding scenarios in a standard cargo container.
△ Less
Submitted 1 February, 2019; v1 submitted 12 November, 2018;
originally announced December 2018.
-
Validation of Geant4's G4NRF module against nuclear resonance fluorescence data from $^{238}$U and $^{27}$Al
Authors:
Jayson R Vavrek,
Brian S Henderson,
Areg Danagoulian
Abstract:
G4NRF is a simulation module for modeling nuclear resonance fluorescence (NRF) interactions in the Geant4 framework. In this work, we validate G4NRF against both absolute and relative measurements of three NRF interactions near 2.2 MeV in $^{238}$U and $^{27}$Al using the transmission NRF data from the experiments described in arXiv:1712.02904. Agreement between the absolute NRF count rates observ…
▽ More
G4NRF is a simulation module for modeling nuclear resonance fluorescence (NRF) interactions in the Geant4 framework. In this work, we validate G4NRF against both absolute and relative measurements of three NRF interactions near 2.2 MeV in $^{238}$U and $^{27}$Al using the transmission NRF data from the experiments described in arXiv:1712.02904. Agreement between the absolute NRF count rates observed in the data and predicted by extensive Geant4+G4NRF modeling validate the combined Geant4+G4NRF to within $15$--$20\%$ in the $^{238}$U NRF transitions and $8\%$ in $^{27}$Al, for an average $13\%$ discrepancy across the entire study. The difference between simulation and experiment in relative NRF rates, as expressed as ratios of count rates in various NRF lines, is found at the level of ${\lesssim}4\%$, and is statistically identical to zero. Inverting the analysis, approximate values of the absolute level widths and branching ratios for $^{238}$U and $^{27}$Al are also obtained.
△ Less
Submitted 5 July, 2019; v1 submitted 6 July, 2018;
originally announced July 2018.
-
High-accuracy Geant4 simulation and semi-analytical modeling of nuclear resonance fluorescence
Authors:
Jayson R Vavrek,
Brian S Henderson,
Areg Danagoulian
Abstract:
Nuclear resonance fluorescence (NRF) is a photonuclear interaction that enables highly isotope-specific measurements in both pure and applied physics scenarios. High-accuracy design and analysis of NRF measurements in complex geometries is aided by Monte Carlo simulations of photon physics and transport, motivating Jordan and Warren (2007) to develop the G4NRF codebase for NRF simulation in Geant4…
▽ More
Nuclear resonance fluorescence (NRF) is a photonuclear interaction that enables highly isotope-specific measurements in both pure and applied physics scenarios. High-accuracy design and analysis of NRF measurements in complex geometries is aided by Monte Carlo simulations of photon physics and transport, motivating Jordan and Warren (2007) to develop the G4NRF codebase for NRF simulation in Geant4. In this work, we enhance the physics accuracy of the G4NRF code and perform improved benchmarking simulations. The NRF cross section calculation in G4NRF, previously a Gaussian approximation, has been replaced with a full numerical integration for improved accuracy in thick-target scenarios. A high-accuracy semi-analytical model of expected NRF count rates in a typical NRF measurement is then constructed and compared against G4NRF simulations for both simple homogeneous and more complex heterogeneous geometries. Agreement between rates predicted by the semi-analytical model and G4NRF simulation is found at a level of ${\sim}1\%$ in simple test cases and ${\sim}3\%$ in more realistic scenarios, improving upon the ${\sim}20\%$ level of the initial benchmarking study and establishing a highly-accurate NRF framework for Geant4.
△ Less
Submitted 30 July, 2018; v1 submitted 3 July, 2018;
originally announced July 2018.
-
Experimental Demonstration of Multiple Monoenergetic Gamma Radiography for Effective Atomic Number Identification in Cargo Inspection
Authors:
Brian S. Henderson,
Hin Y. Lee,
Thomas D. MacDonald,
Roberts G. Nelson,
Areg Danagoulian
Abstract:
The smuggling of special nuclear materials (SNM) through international borders could enable nuclear terrorism and constitutes a significant threat to global security. This paper presents the experimental demonstration of a novel radiographic technique for quantitatively reconstructing the density and type of material present in commercial cargo containers, as a means of detecting such threats. Unl…
▽ More
The smuggling of special nuclear materials (SNM) through international borders could enable nuclear terrorism and constitutes a significant threat to global security. This paper presents the experimental demonstration of a novel radiographic technique for quantitatively reconstructing the density and type of material present in commercial cargo containers, as a means of detecting such threats. Unlike traditional techniques which use sources of bremsstrahlung photons with a continuous distribution of energies, multiple monoenergetic gamma radiography (MMGR) utilizes monoenergetic photons from nuclear reactions, specifically the 4.4 and 15.1 MeV photons from the $^{11}$B(d,n$γ$)$^{12}$C reaction. By exploiting the $Z$-dependence of the photon interaction cross sections at these two specific energies it is possible to simultaneously determine the areal density and the effective atomic number as a function of location for a 2D projection of a scanned object. The additional information gleaned from using and detecting photons of specific energies for radiography substantially increases the resolving power between different materials. This paper presents results from the imaging of mock cargo materials ranging from $Z\approx5$--$92$, demonstrating accurate reconstruction of the effective atomic number and areal density of the materials over the full range. In particular, the system is capable of distinguishing pure materials with $Z\gtrsim70$, such as lead and uranium --- a critical requirement of a system designed to detect SNM. This methodology could be used to screen commercial cargoes with high material specificity, to distinguish most benign materials from SNM, such as uranium and plutonium.
△ Less
Submitted 19 March, 2018; v1 submitted 12 February, 2018;
originally announced February 2018.
-
Experimental demonstration of an isotope-sensitive warhead verification technique using nuclear resonance fluorescence
Authors:
Jayson R Vavrek,
Brian S Henderson,
Areg Danagoulian
Abstract:
Future nuclear arms reduction efforts will require technologies to verify that warheads slated for dismantlement are authentic without revealing any sensitive weapons design information to international inspectors. Despite several decades of research, no technology has met these requirements simultaneously. Recent work by Kemp et al. [Kemp RS, Danagoulian A, Macdonald RR, Vavrek JR (2016) Proc Nat…
▽ More
Future nuclear arms reduction efforts will require technologies to verify that warheads slated for dismantlement are authentic without revealing any sensitive weapons design information to international inspectors. Despite several decades of research, no technology has met these requirements simultaneously. Recent work by Kemp et al. [Kemp RS, Danagoulian A, Macdonald RR, Vavrek JR (2016) Proc Natl Acad Sci USA 113:8618--8623] has produced a novel physical cryptographic verification protocol that approaches this treaty verification problem by exploiting the isotope-specific nature of nuclear resonance fluorescence (NRF) measurements to verify the authenticity of a warhead. To protect sensitive information, the NRF signal from the warhead is convolved with that of an encryption foil that contains key warhead isotopes in amounts unknown to the inspector. The convolved spectrum from a candidate warhead is statistically compared against that from an authenticated template warhead to determine whether the candidate itself is authentic. Here we report on recent proof-of-concept warhead verification experiments conducted at the Massachusetts Institute of Technology. Using high-purity germanium (HPGe) detectors, we measured NRF spectra from the interrogation of proxy 'genuine' and 'hoax' objects by a 2.52 MeV endpoint bremsstrahlung beam. The observed differences in NRF intensities near 2.2 MeV indicate that the physical cryptographic protocol can distinguish between proxy genuine and hoax objects with high confidence in realistic measurement times.
△ Less
Submitted 9 April, 2018; v1 submitted 7 December, 2017;
originally announced December 2017.
-
Nuclear Disarmament Verification via Resonant Phenomena
Authors:
Jake J. Hecla,
Areg Danagoulian
Abstract:
Nuclear disarmament treaties are not sufficient in and of themselves to neutralize the existential threat of the nuclear weapons. Technologies are necessary for verifying the authenticity of the nuclear warheads undergoing dismantlement before counting them towards a treaty partner's obligation. This work presents a novel concept that leverages isotope-specific nuclear resonance phenomena to authe…
▽ More
Nuclear disarmament treaties are not sufficient in and of themselves to neutralize the existential threat of the nuclear weapons. Technologies are necessary for verifying the authenticity of the nuclear warheads undergoing dismantlement before counting them towards a treaty partner's obligation. This work presents a novel concept that leverages isotope-specific nuclear resonance phenomena to authenticate a warhead's fissile components by comparing them to a previously authenticated template. All information is encrypted in the physical domain in a manner that amounts to a physical zero-knowledge proof system. Using Monte Carlo simulations, the system is shown to reveal no isotopic or geometric information about the weapon, while readily detecting hoaxing attempts. This nuclear technique can dramatically increase the reach and trustworthiness of future nuclear disarmament treaties.
△ Less
Submitted 27 September, 2017;
originally announced September 2017.
-
Neutron Beam Effects on Spin Exchange Polarized He-3
Authors:
M. Sharma,
E. Babcock,
K. H. Andersen,
L. Barron-Palos,
M. Becker,
S. Boag,
W. C. Chen,
T. E. Chupp,
A. Danagoulian,
T. R. Gentile,
A. Klein,
S. Penttila,
A. Petoukhov,
T. Soldner,
E. R. Tardiff,
T. G. Walker,
W. S. Wilburn
Abstract:
We have observed depolarization effects when high intensity cold neutron beams are incident on alkali-metal-spin-exchange polarized He-3 cells used as neutron spin filters. This was first observed as a reduction of the maximum attainable He-3 polarization and was attributed to a decrease of alkali-metal polarization, which led us to directly measure alkali-metal polarization and spin relaxation…
▽ More
We have observed depolarization effects when high intensity cold neutron beams are incident on alkali-metal-spin-exchange polarized He-3 cells used as neutron spin filters. This was first observed as a reduction of the maximum attainable He-3 polarization and was attributed to a decrease of alkali-metal polarization, which led us to directly measure alkali-metal polarization and spin relaxation over a range of neutron fluxes at LANSCE and ILL. The data reveal a new alkali-metal spin-relaxation mechanism that approximately scales as the square root of the neutron capture-flux density incident on the cell. This is consistent with an effect proportional to the recombination-limited ion concentration, but is much larger than expected from earlier work.
△ Less
Submitted 21 February, 2008;
originally announced February 2008.
-
An Electromagnetic Calorimeter for the JLab Real Compton Scattering Experiment
Authors:
D. J. Hamilton,
A. Shahinyan,
B. Wojtsekhowski,
J. R. M. Annand,
T. -H. Chang,
E. Chudakov,
A. Danagoulian,
P. Degtyarenko,
K. Egiyan,
R. Gilman,
V. Gorbenko,
J. Hines,
E. Hovhannisyan,
C. E. Hyde-Wright,
C. W. de Jager,
A. Ketikyan,
V. H. Mamyan,
R. Michaels,
A. M. Nathan,
V. Nelyubin,
I. Rachek,
M. Roedelbrom,
A. Petrosyan,
R. Pomatsalyuk,
V. Popov
, et al. (4 additional authors not shown)
Abstract:
A lead-glass hodoscope calorimeter that was constructed for use in the Jefferson Lab Real Compton Scattering experiment is described. The detector provides a measurement of the coordinates and the energy of scattered photons in the GeV energy range with resolutions of 5 mm and 6%/\sqrt(Eγ [GeV]). Features of both the detector design and its performance in the high luminosity environment during the…
▽ More
A lead-glass hodoscope calorimeter that was constructed for use in the Jefferson Lab Real Compton Scattering experiment is described. The detector provides a measurement of the coordinates and the energy of scattered photons in the GeV energy range with resolutions of 5 mm and 6%/\sqrt(Eγ [GeV]). Features of both the detector design and its performance in the high luminosity environment during the experiment are presented.
△ Less
Submitted 25 September, 2015; v1 submitted 14 April, 2007;
originally announced April 2007.
-
Compton Scattering Cross Section on the Proton at High Momentum Transfer
Authors:
A. Danagoulian,
V. H. Mamyan,
M. Roedelbronn,
the Hall A Collaboration
Abstract:
Cross-section values for Compton scattering on the proton were measured at 25 kinematic settings over the range s = 5-11 and -t = 2-7 GeV2 with statistical accuracy of a few percent. The scaling power for the s-dependence of the cross section at fixed center of mass angle was found to be 8.0 +/ 0.2, strongly inconsistent with the prediction of perturbative QCD. The observed cross-section values…
▽ More
Cross-section values for Compton scattering on the proton were measured at 25 kinematic settings over the range s = 5-11 and -t = 2-7 GeV2 with statistical accuracy of a few percent. The scaling power for the s-dependence of the cross section at fixed center of mass angle was found to be 8.0 +/ 0.2, strongly inconsistent with the prediction of perturbative QCD. The observed cross-section values are in fair agreement with the calculations using the handbag mechanism, in which the external photons couple to a single quark.
△ Less
Submitted 30 January, 2007; v1 submitted 28 January, 2007;
originally announced January 2007.