-
High-resolution laser system for the S3-Low Energy Branch
Authors:
Jekabs Romans,
Anjali Ajayakumar,
Martial Authier,
Frederic Boumard,
Lucia Caceres,
Jean-Francois Cam,
Arno Claessens,
Samuel Damoy,
Pierre Delahaye,
Philippe Desrues,
Wenling Dong,
Antoine Drouart,
Patricia Duchesne,
Rafael Ferrer,
Xavier Flechard,
Serge Franchoo,
Patrice Gangnant,
Sarina Geldhof,
Ruben P. de Groote,
Nathalie Lecesne,
Renan Leroy,
Julien Lory,
Franck Lutton,
Vladimir Manea,
Yvan Merrer
, et al. (17 additional authors not shown)
Abstract:
In this paper we present the first high-resolution laser spectroscopy results obtained at the GISELE laser laboratory of the GANIL-SPIRAL2 facility, in preparation for the first experiments with the S$^3$-Low Energy Branch. Studies of neutron-deficient radioactive isotopes of erbium and tin represent the first physics cases to be studied at S$^3$. The measured isotope-shift and hyperfine structure…
▽ More
In this paper we present the first high-resolution laser spectroscopy results obtained at the GISELE laser laboratory of the GANIL-SPIRAL2 facility, in preparation for the first experiments with the S$^3$-Low Energy Branch. Studies of neutron-deficient radioactive isotopes of erbium and tin represent the first physics cases to be studied at S$^3$. The measured isotope-shift and hyperfine structure data are presented for stable isotopes of these elements. The erbium isotopes were studied using the $4f^{12}6s^2$ $^3H_6 \rightarrow 4f^{12}(^3 H)6s6p$ $J = 5$ atomic transition (415 nm) and the tin isotopes were studied by the $5s^25p^2 (^3P_0) \rightarrow 5s^25p6s (^3P_1)$ atomic transition (286.4 nm), and are used as a benchmark of the laser setup. Additionally, the tin isotopes were studied by the $5s^25p6s (^3P_1) \rightarrow 5s^25p6p (^3P_2)$ atomic transition (811.6 nm), for which new isotope-shift data was obtained and the corresponding field-shift $F_{812}$ and mass-shift $M_{812}$ factors are presented.
△ Less
Submitted 9 December, 2022;
originally announced December 2022.
-
The spiral1 charge breeder: key points for a performant 1+ beam injection
Authors:
L. Maunoury,
O. Kamalou,
J. F. Cam,
S. Damoy,
P. Delahaye,
M. Dubois,
R. Frigot,
S. Hormigos,
C. Vandamme
Abstract:
The SPIRAL1 charge breeder is now under operation. Radioactive beam has already been delivered [1] to Physicist for performing experiment. Although charge breeding efficiencies demonstrated high performances for stable ion beams, those efficiencies regarding radioactive ion beams were found, in the first experiments, lower than expected. The beam optics, prior to the injection of the 1+ ions into…
▽ More
The SPIRAL1 charge breeder is now under operation. Radioactive beam has already been delivered [1] to Physicist for performing experiment. Although charge breeding efficiencies demonstrated high performances for stable ion beams, those efficiencies regarding radioactive ion beams were found, in the first experiments, lower than expected. The beam optics, prior to the injection of the 1+ ions into the SPIRAL1 charge breeder, is of prime importance [2] for getting such high efficiencies. Moreover, the intensities of the radioactive ion beams are so low, that it is really difficult to tune the charge breeder. The tuning of the charge breeder for radioactive ion beams requires a particular procedure often referred as blind tuning. A stable beam hav-ing a close Brho (few percent) is required to find out the set of optic parameters preceding the tuning of the radioactive beam. Hence, it has been decided to focus our effort on that procedure as to get control of the 1+ beam optics leading to high charge breeding efficiencies whatever the 1+ mass, energy and Target Ion Source System (TISS) used. Being aware that each TISS provide ion beams with a specific energy spread DeltaE, and given that the acceptance energy win-dow of the charge breeder is rather narrow; that parameter must play also an important role in the whole charge breed-ing efficiency.
△ Less
Submitted 17 December, 2020;
originally announced December 2020.
-
Signature of a possible $α$-cluster state in $N=Z$ doubly-magic $^{56}$Ni
Authors:
S. Bagchi,
H. Akimune,
J. Gibelin,
M. N. Harakeh,
N. Kalantar-Nayestanaki,
N. L. Achouri,
B. Bastin,
K. Boretzky,
H. Bouzomita,
M. Caamaño,
L. Càceres,
S. Damoy,
F. Delaunay,
B. Fernández-Domínguez,
M. Fujiwara,
U. Garg,
G. F. Grinyer,
O. Kamalou,
E. Khan,
A. Krasznahorkay,
G. Lhoutellier,
J. F. Libin,
S. Lukyanov,
K. Mazurek,
M. A. Najafi
, et al. (14 additional authors not shown)
Abstract:
An inelastic $α$-scattering experiment on the unstable $N=Z$, doubly-magic $^{56}$Ni nucleus was performed in inverse kinematics at an incident energy of 50 A.MeV at GANIL. High multiplicity for $α$-particle emission was observed within the limited phase-space of the experimental setup. This observation cannot be explained by means of the statistical-decay model. The ideal classical gas model at…
▽ More
An inelastic $α$-scattering experiment on the unstable $N=Z$, doubly-magic $^{56}$Ni nucleus was performed in inverse kinematics at an incident energy of 50 A.MeV at GANIL. High multiplicity for $α$-particle emission was observed within the limited phase-space of the experimental setup. This observation cannot be explained by means of the statistical-decay model. The ideal classical gas model at $kT$ = 0.4 MeV reproduces fairly well the experimental momentum distribution and the observed multiplicity of $α$ particles corresponds to an excitation energy around 96 MeV. The method of distributed $mα$-decay ensembles is in agreement with the experimental results if we assume that the $α$-gas state in $^{56}$Ni exists at around $113^{+15}_{-17}$ MeV. These results suggest that there may exist an exotic state consisting of many $α$ particles at the excitation energy of $113^{+15}_{-17}$ MeV.
△ Less
Submitted 29 October, 2020;
originally announced October 2020.
-
A large open ratio, time and position sensitive detector for time of flight measurements in UHV
Authors:
S. Lupone,
S. Damoy,
A. Husseen,
N. Briand,
M. Debiossac,
S. Tall,
P. Roncin
Abstract:
We report on the construction of a UHV compatible 40 mm active diameter detector based on micro channel plates and assembled directly on the feed-throughs of a DN63CF flange. It is based on the charge division technique and uses a standard two inch Si wafer as a collector. The front end electronic is placed directly on the air side of the flange allowing excellent immunity to noise and a very good…
▽ More
We report on the construction of a UHV compatible 40 mm active diameter detector based on micro channel plates and assembled directly on the feed-throughs of a DN63CF flange. It is based on the charge division technique and uses a standard two inch Si wafer as a collector. The front end electronic is placed directly on the air side of the flange allowing excellent immunity to noise and a very good timing signal with reduced ringing. The important aberrations are corrected empirically providing and absolute positioning accuracy of 500 $μ$m while a 150 $μ$m resolution is measured in the center.
△ Less
Submitted 10 July, 2015;
originally announced July 2015.