-
XCAT-3.0: A Comprehensive Library of Personalized Digital Twins Derived from CT Scans
Authors:
Lavsen Dahal,
Mobina Ghojoghnejad,
Dhrubajyoti Ghosh,
Yubraj Bhandari,
David Kim,
Fong Chi Ho,
Fakrul Islam Tushar,
Sheng Luoa,
Kyle J. Lafata,
Ehsan Abadi,
Ehsan Samei,
Joseph Y. Lo,
W. Paul Segars
Abstract:
Virtual Imaging Trials (VIT) offer a cost-effective and scalable approach for evaluating medical imaging technologies. Computational phantoms, which mimic real patient anatomy and physiology, play a central role in VIT. However, the current libraries of computational phantoms face limitations, particularly in terms of sample size and diversity. Insufficient representation of the population hampers…
▽ More
Virtual Imaging Trials (VIT) offer a cost-effective and scalable approach for evaluating medical imaging technologies. Computational phantoms, which mimic real patient anatomy and physiology, play a central role in VIT. However, the current libraries of computational phantoms face limitations, particularly in terms of sample size and diversity. Insufficient representation of the population hampers accurate assessment of imaging technologies across different patient groups. Traditionally, phantoms were created by manual segmentation, which is a laborious and time-consuming task, impeding the expansion of phantom libraries. This study presents a framework for realistic computational phantom modeling using a suite of four deep learning segmentation models, followed by three forms of automated organ segmentation quality control. Over 2500 computational phantoms with up to 140 structures illustrating a sophisticated approach to detailed anatomical modeling are released. Phantoms are available in both voxelized and surface mesh formats. The framework is aggregated with an in-house CT scanner simulator to produce realistic CT images. The framework can potentially advance virtual imaging trials, facilitating comprehensive and reliable evaluations of medical imaging technologies. Phantoms may be requested at https://cvit.duke.edu/resources/, code, model weights, and sample CT images are available at https://xcat-3.github.io.
△ Less
Submitted 1 June, 2024; v1 submitted 17 May, 2024;
originally announced May 2024.
-
AI in Lung Health: Benchmarking Detection and Diagnostic Models Across Multiple CT Scan Datasets
Authors:
Fakrul Islam Tushar,
Avivah Wang,
Lavsen Dahal,
Michael R. Harowicz,
Kyle J. Lafata,
Tina D. Tailor,
Joseph Y. Lo
Abstract:
Lung cancer's high mortality rate can be mitigated by early detection, increasingly reliant on AI for diagnostic imaging. However, AI model performance depends on training and validation datasets. This study develops and validates AI models for both nodule detection and cancer classification tasks. For detection, two models (DLCSD-mD and LUNA16-mD) were developed using the Duke Lung Cancer Screeni…
▽ More
Lung cancer's high mortality rate can be mitigated by early detection, increasingly reliant on AI for diagnostic imaging. However, AI model performance depends on training and validation datasets. This study develops and validates AI models for both nodule detection and cancer classification tasks. For detection, two models (DLCSD-mD and LUNA16-mD) were developed using the Duke Lung Cancer Screening Dataset (DLCSD), with over 2,000 CT scans from 1,613 patients and more than 3,000 annotations. These models were evaluated on internal (DLCSD) and external datasets, including LUNA16 (601 patients, 1186 nodules) and NLST (969 patients, 1192 nodules), using FROC analysis and AUC metrics. For classification, five models were developed and tested: a randomly initialized 3D ResNet50, Genesis, MedNet3D, an enhanced ResNet50 using Strategic Warm-Start++ (SWS++), and a linear classifier analyzing features from the Foundation Model for Cancer Biomarkers (FMCB). These models were trained to distinguish between benign and malignant nodules and evaluated using AUC analysis on internal (DLCSD) and external datasets, including LUNA16 (433 patients, 677 nodules) and NLST. The DLCSD-mD model achieved an AUC of 0.93 (95% CI: 0.91-0.94) on the internal DLCSD dataset. External validation results were 0.97 (95% CI: 0.96-0.98) on LUNA16 and 0.75 (95% CI: 0.73-0.76) on NLST. For classification, the ResNet50-SWS++ model recorded AUCs of 0.71 (95% CI: 0.61-0.81) on DLCSD, 0.90 (95% CI: 0.87-0.93) on LUNA16, and 0.81 (95% CI: 0.79-0.82) on NLST. Other models showed varying performance across datasets, underscoring the importance of diverse model approaches. This benchmarking establishes DLCSD as a reliable resource for lung cancer AI research.
△ Less
Submitted 12 June, 2024; v1 submitted 7 May, 2024;
originally announced May 2024.
-
VLST: Virtual Lung Screening Trial for Lung Cancer Detection Using Virtual Imaging Trial
Authors:
Fakrul Islam Tushar,
Liesbeth Vancoillie,
Cindy McCabe,
Amareswararao Kavuri,
Lavsen Dahal,
Brian Harrawood,
Milo Fryling,
Mojtaba Zarei,
Saman Sotoudeh-Paima,
Fong Chi Ho,
Dhrubajyoti Ghosh,
Sheng Luo,
W. Paul Segars,
Ehsan Abadi,
Kyle J. Lafata,
Ehsan Samei,
Joseph Y. Lo
Abstract:
Importance: The efficacy of lung cancer screening can be significantly impacted by the imaging modality used. This Virtual Lung Screening Trial (VLST) addresses the critical need for precision in lung cancer diagnostics and the potential for reducing unnecessary radiation exposure in clinical settings.
Objectives: To establish a virtual imaging trial (VIT) platform that accurately simulates real…
▽ More
Importance: The efficacy of lung cancer screening can be significantly impacted by the imaging modality used. This Virtual Lung Screening Trial (VLST) addresses the critical need for precision in lung cancer diagnostics and the potential for reducing unnecessary radiation exposure in clinical settings.
Objectives: To establish a virtual imaging trial (VIT) platform that accurately simulates real-world lung screening trials (LSTs) to assess the diagnostic accuracy of CT and CXR modalities.
Design, Setting, and Participants: Utilizing computational models and machine learning algorithms, we created a diverse virtual patient population. The cohort, designed to mirror real-world demographics, was assessed using virtual imaging techniques that reflect historical imaging technologies.
Main Outcomes and Measures: The primary outcome was the difference in the Area Under the Curve (AUC) for CT and CXR modalities across lesion types and sizes.
Results: The study analyzed 298 CT and 313 CXR simulated images from 313 virtual patients, with a lesion-level AUC of 0.81 (95% CI: 0.78-0.84) for CT and 0.55 (95% CI: 0.53-0.56) for CXR. At the patient level, CT demonstrated an AUC of 0.85 (95% CI: 0.80-0.89), compared to 0.53 (95% CI: 0.47-0.60) for CXR. Subgroup analyses indicated CT's superior performance in detecting homogeneous lesions (AUC of 0.97 for lesion-level) and heterogeneous lesions (AUC of 0.71 for lesion-level) as well as in identifying larger nodules (AUC of 0.98 for nodules > 8 mm).
Conclusion and Relevance: The VIT platform validated the superior diagnostic accuracy of CT over CXR, especially for smaller nodules, underscoring its potential to replicate real clinical imaging trials. These findings advocate for the integration of virtual trials in the evaluation and improvement of imaging-based diagnostic tools.
△ Less
Submitted 17 April, 2024;
originally announced April 2024.
-
Large Intestine 3D Shape Refinement Using Point Diffusion Models for Digital Phantom Generation
Authors:
Kaouther Mouheb,
Mobina Ghojogh Nejad,
Lavsen Dahal,
Ehsan Samei,
Kyle J. Lafata,
W. Paul Segars,
Joseph Y. Lo
Abstract:
Accurate 3D modeling of human organs plays a crucial role in building computational phantoms for virtual imaging trials. However, generating anatomically plausible reconstructions of organ surfaces from computed tomography scans remains challenging for many structures in the human body. This challenge is particularly evident when dealing with the large intestine. In this study, we leverage recent…
▽ More
Accurate 3D modeling of human organs plays a crucial role in building computational phantoms for virtual imaging trials. However, generating anatomically plausible reconstructions of organ surfaces from computed tomography scans remains challenging for many structures in the human body. This challenge is particularly evident when dealing with the large intestine. In this study, we leverage recent advancements in geometric deep learning and denoising diffusion probabilistic models to refine the segmentation results of the large intestine. We begin by representing the organ as point clouds sampled from the surface of the 3D segmentation mask. Subsequently, we employ a hierarchical variational autoencoder to obtain global and local latent representations of the organ's shape. We train two conditional denoising diffusion models in the hierarchical latent space to perform shape refinement. To further enhance our method, we incorporate a state-of-the-art surface reconstruction model, allowing us to generate smooth meshes from the obtained complete point clouds. Experimental results demonstrate the effectiveness of our approach in capturing both the global distribution of the organ's shape and its fine details. Our complete refinement pipeline demonstrates remarkable enhancements in surface representation compared to the initial segmentation, reducing the Chamfer distance by 70%, the Hausdorff distance by 32%, and the Earth Mover's distance by 6%. By combining geometric deep learning, denoising diffusion models, and advanced surface reconstruction techniques, our proposed method offers a promising solution for accurately modeling the large intestine's surface and can easily be extended to other anatomical structures.
△ Less
Submitted 20 May, 2024; v1 submitted 15 September, 2023;
originally announced September 2023.
-
Virtual imaging trials improved the transparency and reliability of AI systems in COVID-19 imaging
Authors:
Fakrul Islam Tushar,
Lavsen Dahal,
Saman Sotoudeh-Paima,
Ehsan Abadi,
W. Paul Segars,
Ehsan Samei,
Joseph Y. Lo
Abstract:
The credibility of AI models in medical imaging is often challenged by reproducibility issues and obscured clinical insights, a reality highlighted during the COVID-19 pandemic by many reports of near-perfect artificial intelligence (AI) models that all failed to generalize. To address these concerns, we propose a virtual imaging trial framework, employing a diverse collection of medical images th…
▽ More
The credibility of AI models in medical imaging is often challenged by reproducibility issues and obscured clinical insights, a reality highlighted during the COVID-19 pandemic by many reports of near-perfect artificial intelligence (AI) models that all failed to generalize. To address these concerns, we propose a virtual imaging trial framework, employing a diverse collection of medical images that are both clinical and simulated. In this study, COVID-19 serves as a case example to unveil the intrinsic and extrinsic factors influencing AI performance. Our findings underscore a significant impact of dataset characteristics on AI efficacy. Even when trained on large, diverse clinical datasets with thousands of patients, AI performance plummeted by up to 20% in generalization. However, virtual imaging trials offer a robust platform for objective assessment, unveiling nuanced insights into the relationships between patient- and physics-based factors and AI performance. For instance, disease extent markedly influenced AI efficacy, computed tomography (CT) out-performed chest radiography (CXR), while imaging dose exhibited minimal impact. Using COVID-19 as a case study, this virtual imaging trial study verified that radiology AI models often suffer from a reproducibility crisis. Virtual imaging trials not only offered a solution for objective performance assessment but also extracted several clinical insights. This study illuminates the path for leveraging virtual imaging to augment the reliability, transparency, and clinical relevance of AI in medical imaging.
△ Less
Submitted 31 March, 2024; v1 submitted 17 August, 2023;
originally announced August 2023.
-
Uncertainty Estimation in Deep 2D Echocardiography Segmentation
Authors:
Lavsen Dahal,
Aayush Kafle,
Bishesh Khanal
Abstract:
2D echocardiography is the most common imaging modality for cardiovascular diseases. The portability and relatively low-cost nature of Ultrasound (US) enable the US devices needed for performing echocardiography to be made widely available. However, acquiring and interpreting cardiac US images is operator dependent, limiting its use to only places where experts are present. Recently, Deep Learning…
▽ More
2D echocardiography is the most common imaging modality for cardiovascular diseases. The portability and relatively low-cost nature of Ultrasound (US) enable the US devices needed for performing echocardiography to be made widely available. However, acquiring and interpreting cardiac US images is operator dependent, limiting its use to only places where experts are present. Recently, Deep Learning (DL) has been used in 2D echocardiography for automated view classification, and structure and function assessment. Although these recent works show promise in develo** computer-guided acquisition and automated interpretation of echocardiograms, most of these methods do not model and estimate uncertainty which can be important when testing on data coming from a distribution further away from that of the training data. Uncertainty estimates can be beneficial both during the image acquisition phase (by providing real-time feedback to the operator on acquired image's quality), and during automated measurement and interpretation. The performance of uncertainty models and quantification metric may depend on the prediction task and the models being compared. Hence, to gain insight of uncertainty modelling for left ventricular segmentation from US images, we compare three ensembling based uncertainty models quantified using four different metrics (one newly proposed) on state-of-the-art baseline networks using two publicly available echocardiogram datasets. We further demonstrate how uncertainty estimation can be used to automatically reject poor quality images and improve state-of-the-art segmentation results.
△ Less
Submitted 19 May, 2020;
originally announced May 2020.
-
Automatic Cobb Angle Detection using Vertebra Detector and Vertebra Corners Regression
Authors:
Bidur Khanal,
Lavsen Dahal,
Prashant Adhikari,
Bishesh Khanal
Abstract:
Correct evaluation and treatment of Scoliosis require accurate estimation of spinal curvature. Current gold standard is to manually estimate Cobb Angles in spinal X-ray images which is time consuming and has high inter-rater variability. We propose an automatic method with a novel framework that first detects vertebrae as objects followed by a landmark detector that estimates the 4 landmark corner…
▽ More
Correct evaluation and treatment of Scoliosis require accurate estimation of spinal curvature. Current gold standard is to manually estimate Cobb Angles in spinal X-ray images which is time consuming and has high inter-rater variability. We propose an automatic method with a novel framework that first detects vertebrae as objects followed by a landmark detector that estimates the 4 landmark corners of each vertebra separately. Cobb Angles are calculated using the slope of each vertebra obtained from the predicted landmarks. For inference on test data, we perform pre and post processings that include crop**, outlier rejection and smoothing of the predicted landmarks. The results were assessed in AASCE MICCAI challenge 2019 which showed a promise with a SMAPE score of 25.69 on the challenge test set.
△ Less
Submitted 30 October, 2019;
originally announced October 2019.
-
DSNet: Automatic Dermoscopic Skin Lesion Segmentation
Authors:
Md. Kamrul Hasan,
Lavsen Dahal,
Prasad N. Samarakoon,
Fakrul Islam Tushar,
Robert Marti Marly
Abstract:
Automatic segmentation of skin lesion is considered a crucial step in Computer Aided Diagnosis (CAD) for melanoma diagnosis. Despite its significance, skin lesion segmentation remains a challenging task due to their diverse color, texture, and indistinguishable boundaries and forms an open problem. Through this study, we present a new and automatic semantic segmentation network for robust skin les…
▽ More
Automatic segmentation of skin lesion is considered a crucial step in Computer Aided Diagnosis (CAD) for melanoma diagnosis. Despite its significance, skin lesion segmentation remains a challenging task due to their diverse color, texture, and indistinguishable boundaries and forms an open problem. Through this study, we present a new and automatic semantic segmentation network for robust skin lesion segmentation named Dermoscopic Skin Network (DSNet). In order to reduce the number of parameters to make the network lightweight, we used depth-wise separable convolution in lieu of standard convolution to project the learned discriminating features onto the pixel space at different stages of the encoder. Additionally, we implemented U-Net and Fully Convolutional Network (FCN8s) to compare against the proposed DSNet. We evaluate our proposed model on two publicly available datasets, namely ISIC-2017 and PH2. The obtained mean Intersection over Union (mIoU) is 77.5 % and 87.0 % respectively for ISIC-2017 and PH2 datasets which outperformed the ISIC-2017 challenge winner by 1.0 % with respect to mIoU. Our proposed network also outperformed U-Net and FCN8s respectively by 3.6 % and 6.8 % with respect to mIoU on the ISIC-2017 dataset. Our network for skin lesion segmentation outperforms other methods and can provide better segmented masks on two different test datasets which can lead to better performance in melanoma detection. Our trained model along with the source code and predicted masks are made publicly available.
△ Less
Submitted 23 January, 2020; v1 submitted 9 July, 2019;
originally announced July 2019.
-
Brain Tissue Segmentation Using NeuroNet With Different Pre-processing Techniques
Authors:
Fakrul Islam Tushar,
Basel Alyafi,
Md. Kamrul Hasan,
Lavsen Dahal
Abstract:
Automatic segmentation of brain Magnetic Resonance Imaging (MRI) images is one of the vital steps for quantitative analysis of brain for further inspection. In this paper, NeuroNet has been adopted to segment the brain tissues (white matter (WM), grey matter (GM) and cerebrospinal fluid (CSF)) which uses Residual Network (ResNet) in encoder and Fully Convolution Network (FCN) in the decoder. To ac…
▽ More
Automatic segmentation of brain Magnetic Resonance Imaging (MRI) images is one of the vital steps for quantitative analysis of brain for further inspection. In this paper, NeuroNet has been adopted to segment the brain tissues (white matter (WM), grey matter (GM) and cerebrospinal fluid (CSF)) which uses Residual Network (ResNet) in encoder and Fully Convolution Network (FCN) in the decoder. To achieve the best performance, various hyper-parameters have been tuned, while, network parameters (kernel and bias) were initialized using the NeuroNet pre-trained model. Different pre-processing pipelines have also been introduced to get a robust trained model. The model has been trained and tested on IBSR18 data-set. To validate the research outcome, performance was measured quantitatively using Dice Similarity Coefficient (DSC) and is reported on average as 0.84 for CSF, 0.94 for GM, and 0.94 for WM. The outcome of the research indicates that for the IBSR18 data-set, pre-processing and proper tuning of hyper-parameters for NeuroNet model have improvement in DSC for the brain tissue segmentation.
△ Less
Submitted 29 March, 2019;
originally announced April 2019.