-
Dual-encoded magnetization transfer and diffusion imaging and its application to tract-specific microstructure map**
Authors:
Ilana R Leppert,
Pietro Bontempi,
Christopher D Rowley,
Jennifer SW Campbell,
Mark C Nelson,
Simona Schiavi,
G Bruce Pike,
Alessandro Daducci,
Christine L Tardif
Abstract:
We present a novel dual-encoded magnetization transfer (MT) and diffusion-weighted sequence and demonstrate its potential to resolve distinct properties of white matter fiber tracts at the sub-voxel level. The sequence was designed and optimized for maximal MT contrast efficiency. The resulting whole brain 2.6 mm isotropic protocol to measure tract-specific MT ratio (MTR) has a scan time under 7 m…
▽ More
We present a novel dual-encoded magnetization transfer (MT) and diffusion-weighted sequence and demonstrate its potential to resolve distinct properties of white matter fiber tracts at the sub-voxel level. The sequence was designed and optimized for maximal MT contrast efficiency. The resulting whole brain 2.6 mm isotropic protocol to measure tract-specific MT ratio (MTR) has a scan time under 7 minutes. Ten healthy subjects were scanned twice to assess repeatability. Two different analysis methods were contrasted: a technique to extract tract-specific MTR using Convex Optimization Modeling for Microstructure Informed Tractography (COMMIT), a global optimization technique; and conventional MTR tractometry. The results demonstrate that the tract-specific method can reliably resolve the MT ratios of major white matter fiber pathways and is less affected by partial volume effects than conventional multi-modal tractometry. Dual-encoded MT and diffusion is expected to both increase the sensitivity to microstructure alterations of specific tracts due to disease, ageing or learning, as well as lead to weighted structural connectomes with more anatomical specificity.
△ Less
Submitted 6 March, 2023;
originally announced March 2023.
-
Quantitative map** of the brain's structural connectivity using diffusion MRI tractography: a review
Authors:
Fan Zhang,
Alessandro Daducci,
Yong He,
Simona Schiavi,
Caio Seguin,
Robert Smith,
Chun-Hung Yeh,
Tengda Zhao,
Lauren J. O'Donnell
Abstract:
Diffusion magnetic resonance imaging (dMRI) tractography is an advanced imaging technique that enables in vivo map** of the brain's white matter connections at macro scale. Over the last two decades, the study of brain connectivity using dMRI tractography has played a prominent role in the neuroimaging research landscape. In this paper, we provide a high-level overview of how tractography is use…
▽ More
Diffusion magnetic resonance imaging (dMRI) tractography is an advanced imaging technique that enables in vivo map** of the brain's white matter connections at macro scale. Over the last two decades, the study of brain connectivity using dMRI tractography has played a prominent role in the neuroimaging research landscape. In this paper, we provide a high-level overview of how tractography is used to enable quantitative analysis of the brain's structural connectivity in health and disease. We first provide a review of methodology involved in three main processing steps that are common across most approaches for quantitative analysis of tractography, including methods for tractography correction, segmentation and quantification. For each step, we aim to describe methodological choices, their popularity, and potential pros and cons. We then review studies that have used quantitative tractography approaches to study the brain's white matter, focusing on applications in neurodevelopment, aging, neurological disorders, mental disorders, and neurosurgery. We conclude that, while there have been considerable advancements in methodological technologies and breadth of applications, there nevertheless remains no consensus about the "best" methodology in quantitative analysis of tractography, and researchers should remain cautious when interpreting results in research and clinical applications.
△ Less
Submitted 23 April, 2021;
originally announced April 2021.
-
Efficient sampling and robust 3D diffusion magnetic resonance imaging signal reconstruction
Authors:
Alice P. Bates,
Zubair Khalid,
Jason D. McEwen,
Rodney A. Kennedy,
Alessandro Daducci,
Erick J. Canales-Rodríguez
Abstract:
This paper presents novel single and multi-shell sampling schemes for diffusion MRI. In diffusion MRI, it is paramount that the number of samples is as small as possible in order that scan times are practical in a clinical setting. The proposed schemes use an efficient number of measurements in that the number of samples is equal to the degrees of freedom in the orthonormal bases used for reconstr…
▽ More
This paper presents novel single and multi-shell sampling schemes for diffusion MRI. In diffusion MRI, it is paramount that the number of samples is as small as possible in order that scan times are practical in a clinical setting. The proposed schemes use an efficient number of measurements in that the number of samples is equal to the degrees of freedom in the orthonormal bases used for reconstruction. Novel reconstruction algorithms based on smaller subsystems of linear equations, as compared to the standard regularized least-squares method, are developed for both single and multi-shells sampling schemes. The smaller matrices used in these novel reconstruction algorithms are designed to be well-conditioned, leading to improved reconstruction accuracy. Accurate and robust reconstruction is also achieved through incorporation of regularization into the novel reconstruction algorithms and using a Rician or non-central Chi noise model. We quantitatively validate our single and multi-shell schemes against standard least-squares reconstruction methods to show that they enable more accurate reconstruction when the number of samples is equal to the degrees of freedom in the basis. Human brain data is also used to qualitatively evaluate reconstruction
△ Less
Submitted 30 January, 2019; v1 submitted 25 July, 2018;
originally announced July 2018.
-
Fast Fiber Orientation Estimation in Diffusion MRI from kq-Space Sampling and Anatomical Priors
Authors:
Marica Pesce,
Audrey Repetti,
Anna Auría,
Alessandro Daducci,
Jean-Philippe Thiran,
Yves Wiaux
Abstract:
High spatio-angular resolution diffusion MRI (dMRI) has been shown to provide accurate identification of complex neuronal fiber configurations, albeit, at the cost of long acquisition times. We propose a method to recover intra-voxel fiber configurations at high spatio-angular resolution relying on a 3D kq-space under-sampling scheme to enable accelerated acquisitions. Simulations and real data an…
▽ More
High spatio-angular resolution diffusion MRI (dMRI) has been shown to provide accurate identification of complex neuronal fiber configurations, albeit, at the cost of long acquisition times. We propose a method to recover intra-voxel fiber configurations at high spatio-angular resolution relying on a 3D kq-space under-sampling scheme to enable accelerated acquisitions. Simulations and real data analysis suggest that accurate FOD map** can be achieved from severe kq-space under-sampling regimes potentially enabling high spatio-angular resolution dMRI in the clinical setting.
△ Less
Submitted 5 December, 2021; v1 submitted 8 February, 2018;
originally announced February 2018.
-
Spherical deconvolution of multichannel diffusion MRI data with non-Gaussian noise models and spatial regularization
Authors:
Erick J. Canales-Rodríguez,
Alessandro Daducci,
Stamatios N. Sotiropoulos,
Emmanuel Caruyer,
Santiago Aja-Fernández,
Joaquim Radua,
Jesús María Yurramendi Mendizabal,
Yasser Iturria-Medina,
Lester Melie-García,
Yasser Alemán-Gómez,
Jean-Philippe Thiran,
Salvador Sarró,
Edith Pomarol-Clotet,
Raymond Salvador
Abstract:
Spherical deconvolution (SD) methods are widely used to estimate the intra-voxel white-matter fiber orientations from diffusion MRI data. However, while some of these methods assume a zero-mean Gaussian distribution for the underlying noise, its real distribution is known to be non-Gaussian and to depend on the methodology used to combine multichannel signals. Indeed, the two prevailing methods fo…
▽ More
Spherical deconvolution (SD) methods are widely used to estimate the intra-voxel white-matter fiber orientations from diffusion MRI data. However, while some of these methods assume a zero-mean Gaussian distribution for the underlying noise, its real distribution is known to be non-Gaussian and to depend on the methodology used to combine multichannel signals. Indeed, the two prevailing methods for multichannel signal combination lead to Rician and noncentral Chi noise distributions. Here we develop a Robust and Unbiased Model-BAsed Spherical Deconvolution (RUMBA-SD) technique, intended to deal with realistic MRI noise, based on a Richardson-Lucy (RL) algorithm adapted to Rician and noncentral Chi likelihood models. To quantify the benefits of using proper noise models, RUMBA-SD was compared with dRL-SD, a well-established method based on the RL algorithm for Gaussian noise. Another aim of the study was to quantify the impact of including a total variation (TV) spatial regularization term in the estimation framework. To do this, we developed TV spatially-regularized versions of both RUMBA-SD and dRL-SD algorithms. The evaluation was performed by comparing various quality metrics on 132 three-dimensional synthetic phantoms involving different inter-fiber angles and volume fractions, which were contaminated with noise mimicking patterns generated by data processing in multichannel scanners. The results demonstrate that the inclusion of proper likelihood models leads to an increased ability to resolve fiber crossings with smaller inter-fiber angles and to better detect non-dominant fibers. The inclusion of TV regularization dramatically improved the resolution power of both techniques. The above findings were also verified in brain data.
△ Less
Submitted 8 October, 2015; v1 submitted 23 October, 2014;
originally announced October 2014.
-
Sparse regularization for fiber ODF reconstruction: from the suboptimality of $\ell_2$ and $\ell_1$ priors to $\ell_0$
Authors:
Alessandro Daducci,
Dimitri Van De Ville,
Jean-Philippe Thiran,
Yves Wiaux
Abstract:
Diffusion MRI is a well established imaging modality providing a powerful way to probe the structure of the white matter non-invasively. Despite its potential, the intrinsic long scan times of these sequences have hampered their use in clinical practice. For this reason, a large variety of methods have been recently proposed to shorten the acquisition times. Among them, spherical deconvolution app…
▽ More
Diffusion MRI is a well established imaging modality providing a powerful way to probe the structure of the white matter non-invasively. Despite its potential, the intrinsic long scan times of these sequences have hampered their use in clinical practice. For this reason, a large variety of methods have been recently proposed to shorten the acquisition times. Among them, spherical deconvolution approaches have gained a lot of interest for their ability to reliably recover the intra-voxel fiber configuration with a relatively small number of data samples. To overcome the intrinsic instabilities of deconvolution, these methods use regularization schemes generally based on the assumption that the fiber orientation distribution (FOD) to be recovered in each voxel is sparse. The well known Constrained Spherical Deconvolution (CSD) approach resorts to Tikhonov regularization, based on an l2-norm prior, which promotes a weak version of sparsity. Also, in the last few years compressed sensing has been advocated to further accelerate the acquisitions and l1-norm minimization is generally employed as a means to promote sparsity in the recovered FODs. In this paper, we provide evidence that the use of an l1-norm prior to regularize this class of problems is somewhat inconsistent with the fact that the fiber compartments all sum up to unity. To overcome this l1 inconsistency while simultaneously exploiting sparsity more optimally than through an l2 prior, we reformulate the reconstruction problem as a constrained formulation between a data term and and a sparsity prior consisting in an explicit bound on the l0 norm of the FOD, i.e. on the number of fibers. The method has been tested both on synthetic and real data. Experimental results show that the proposed l0 formulation significantly reduces modeling errors compared to the state-of-the-art l2 and l1 regularization approaches.
△ Less
Submitted 28 December, 2013; v1 submitted 10 August, 2012;
originally announced August 2012.
-
Harmonic analysis of spherical sampling in diffusion MRI
Authors:
A. Daducci,
J. D. McEwen,
D. Van De Ville,
J. -Ph. Thiran,
Y. Wiaux
Abstract:
In the last decade diffusion MRI has become a powerful tool to non-invasively study white-matter integrity in the brain. Recently many research groups have focused their attention on multi-shell spherical acquisitions with the aim of effectively map** the diffusion signal with a lower number of q-space samples, hence enabling a crucial reduction of acquisition time. One of the quantities commonl…
▽ More
In the last decade diffusion MRI has become a powerful tool to non-invasively study white-matter integrity in the brain. Recently many research groups have focused their attention on multi-shell spherical acquisitions with the aim of effectively map** the diffusion signal with a lower number of q-space samples, hence enabling a crucial reduction of acquisition time. One of the quantities commonly studied in this context is the so-called orientation distribution function (ODF). In this setting, the spherical harmonic (SH) transform has gained a great deal of popularity thanks to its ability to perform convolution operations efficiently and accurately, such as the Funk-Radon transform notably required for ODF computation from q-space data. However, if the q-space signal is described with an unsuitable angular resolution at any b-value probed, aliasing (or interpolation) artifacts are unavoidably created. So far this aspect has been tackled empirically and, to our knowledge, no study has addressed this problem in a quantitative approach. The aim of the present work is to study more theoretically the efficiency of multi-shell spherical sampling in diffusion MRI, in order to gain understanding in HYDI-like approaches, possibly paving the way to further optimization strategies.
△ Less
Submitted 1 June, 2011;
originally announced June 2011.