-
Detailed Report on the Measurement of the Positive Muon Anomalous Magnetic Moment to 0.20 ppm
Authors:
D. P. Aguillard,
T. Albahri,
D. Allspach,
A. Anisenkov,
K. Badgley,
S. Baeßler,
I. Bailey,
L. Bailey,
V. A. Baranov,
E. Barlas-Yucel,
T. Barrett,
E. Barzi,
F. Bedeschi,
M. Berz,
M. Bhattacharya,
H. P. Binney,
P. Bloom,
J. Bono,
E. Bottalico,
T. Bowcock,
S. Braun,
M. Bressler,
G. Cantatore,
R. M. Carey,
B. C. K. Casey
, et al. (168 additional authors not shown)
Abstract:
We present details on a new measurement of the muon magnetic anomaly, $a_μ= (g_μ-2)/2$. The result is based on positive muon data taken at Fermilab's Muon Campus during the 2019 and 2020 accelerator runs. The measurement uses $3.1$ GeV$/c$ polarized muons stored in a $7.1$-m-radius storage ring with a $1.45$ T uniform magnetic field. The value of $ a_μ$ is determined from the measured difference b…
▽ More
We present details on a new measurement of the muon magnetic anomaly, $a_μ= (g_μ-2)/2$. The result is based on positive muon data taken at Fermilab's Muon Campus during the 2019 and 2020 accelerator runs. The measurement uses $3.1$ GeV$/c$ polarized muons stored in a $7.1$-m-radius storage ring with a $1.45$ T uniform magnetic field. The value of $ a_μ$ is determined from the measured difference between the muon spin precession frequency and its cyclotron frequency. This difference is normalized to the strength of the magnetic field, measured using Nuclear Magnetic Resonance (NMR). The ratio is then corrected for small contributions from beam motion, beam dispersion, and transient magnetic fields. We measure $a_μ= 116 592 057 (25) \times 10^{-11}$ (0.21 ppm). This is the world's most precise measurement of this quantity and represents a factor of $2.2$ improvement over our previous result based on the 2018 dataset. In combination, the two datasets yield $a_μ(\text{FNAL}) = 116 592 055 (24) \times 10^{-11}$ (0.20 ppm). Combining this with the measurements from Brookhaven National Laboratory for both positive and negative muons, the new world average is $a_μ$(exp) $ = 116 592 059 (22) \times 10^{-11}$ (0.19 ppm).
△ Less
Submitted 22 May, 2024; v1 submitted 23 February, 2024;
originally announced February 2024.
-
Quasidiscrete spectrum Cherenkov radiation by a charge moving inside a dielectric waveguide
Authors:
A. A. Saharian,
S. B. Dabagov,
H. F. Khachatryan,
L. Sh. Grigoryan
Abstract:
We investigate the Cherenkov radiation by a charge uniformly moving inside a dielectric cylindrical channel in a homogeneous medium. The expressions for the Fourier components of the electric and magnetic fields are derived by using the electromagnetic field Green tensor. The spectral distribution of the Cherenkov radiation intensity in the exterior medium is studied for the general case of freque…
▽ More
We investigate the Cherenkov radiation by a charge uniformly moving inside a dielectric cylindrical channel in a homogeneous medium. The expressions for the Fourier components of the electric and magnetic fields are derived by using the electromagnetic field Green tensor. The spectral distribution of the Cherenkov radiation intensity in the exterior medium is studied for the general case of frequency dispersion of the interior and exterior dielectric functions. It is shown that, under certain conditions on the dielectric permittivities, strong narrow peaks appear in the spectral distribution. The spectral locations of those peaks are specified and their heights and widths are estimated analytically on the base of the dispersion equation for the electromagnetic eigenmodes of the cylinder.
△ Less
Submitted 18 June, 2024; v1 submitted 11 February, 2024;
originally announced February 2024.
-
Measurement of the Positive Muon Anomalous Magnetic Moment to 0.20 ppm
Authors:
D. P. Aguillard,
T. Albahri,
D. Allspach,
A. Anisenkov,
K. Badgley,
S. Baeßler,
I. Bailey,
L. Bailey,
V. A. Baranov,
E. Barlas-Yucel,
T. Barrett,
E. Barzi,
F. Bedeschi,
M. Berz,
M. Bhattacharya,
H. P. Binney,
P. Bloom,
J. Bono,
E. Bottalico,
T. Bowcock,
S. Braun,
M. Bressler,
G. Cantatore,
R. M. Carey,
B. C. K. Casey
, et al. (166 additional authors not shown)
Abstract:
We present a new measurement of the positive muon magnetic anomaly, $a_μ\equiv (g_μ- 2)/2$, from the Fermilab Muon $g\!-\!2$ Experiment using data collected in 2019 and 2020. We have analyzed more than 4 times the number of positrons from muon decay than in our previous result from 2018 data. The systematic error is reduced by more than a factor of 2 due to better running conditions, a more stable…
▽ More
We present a new measurement of the positive muon magnetic anomaly, $a_μ\equiv (g_μ- 2)/2$, from the Fermilab Muon $g\!-\!2$ Experiment using data collected in 2019 and 2020. We have analyzed more than 4 times the number of positrons from muon decay than in our previous result from 2018 data. The systematic error is reduced by more than a factor of 2 due to better running conditions, a more stable beam, and improved knowledge of the magnetic field weighted by the muon distribution, $\tildeω'^{}_p$, and of the anomalous precession frequency corrected for beam dynamics effects, $ω_a$. From the ratio $ω_a / \tildeω'^{}_p$, together with precisely determined external parameters, we determine $a_μ= 116\,592\,057(25) \times 10^{-11}$ (0.21 ppm). Combining this result with our previous result from the 2018 data, we obtain $a_μ\text{(FNAL)} = 116\,592\,055(24) \times 10^{-11}$ (0.20 ppm). The new experimental world average is $a_μ(\text{Exp}) = 116\,592\,059(22)\times 10^{-11}$ (0.19 ppm), which represents a factor of 2 improvement in precision.
△ Less
Submitted 4 October, 2023; v1 submitted 11 August, 2023;
originally announced August 2023.
-
A first test of CUPID prototypal light detectors with NTD-Ge sensors in a pulse-tube cryostat
Authors:
CUPID collaboration,
K. Alfonso,
A. Armatol,
C. Augier,
F. T. Avignone III,
O. Azzolini,
M. Balata,
A. S. Barabash,
G. Bari,
A. Barresi,
D. Baudin,
F. Bellini,
G. Benato,
V. Berest,
M. Beretta,
M. Bettelli,
M. Biassoni,
J. Billard,
V. Boldrini,
A. Branca,
C. Brofferio,
C. Bucci,
J. Camilleri,
A. Campani,
C. Capelli
, et al. (154 additional authors not shown)
Abstract:
CUPID is a next-generation bolometric experiment aiming at searching for neutrinoless double-beta decay with ~250 kg of isotopic mass of $^{100}$Mo. It will operate at $\sim$10 mK in a cryostat currently hosting a similar-scale bolometric array for the CUORE experiment at the Gran Sasso National Laboratory (Italy). CUPID will be based on large-volume scintillating bolometers consisting of…
▽ More
CUPID is a next-generation bolometric experiment aiming at searching for neutrinoless double-beta decay with ~250 kg of isotopic mass of $^{100}$Mo. It will operate at $\sim$10 mK in a cryostat currently hosting a similar-scale bolometric array for the CUORE experiment at the Gran Sasso National Laboratory (Italy). CUPID will be based on large-volume scintillating bolometers consisting of $^{100}$Mo-enriched Li$_2$MoO$_4$ crystals, facing thin Ge-wafer-based bolometric light detectors. In the CUPID design, the detector structure is novel and needs to be validated. In particular, the CUORE cryostat presents a high level of mechanical vibrations due to the use of pulse tubes and the effect of vibrations on the detector performance must be investigated. In this paper we report the first test of the CUPID-design bolometric light detectors with NTD-Ge sensors in a dilution refrigerator equipped with a pulse tube in an above-ground lab. Light detectors are characterized in terms of sensitivity, energy resolution, pulse time constants, and noise power spectrum. Despite the challenging noisy environment due to pulse-tube-induced vibrations, we demonstrate that all the four tested light detectors comply with the CUPID goal in terms of intrinsic energy resolution of 100 eV RMS baseline noise. Indeed, we have measured 70--90 eV RMS for the four devices, which show an excellent reproducibility. We have also obtained outstanding energy resolutions at the 356 keV line from a $^{133}$Ba source with one light detector achieving 0.71(5) keV FWHM, which is -- to our knowledge -- the best ever obtained when compared to $γ$ detectors of any technology in this energy range.
△ Less
Submitted 10 April, 2023;
originally announced April 2023.
-
Twelve-crystal prototype of Li$_2$MoO$_4$ scintillating bolometers for CUPID and CROSS experiments
Authors:
CUPID,
CROSS collaborations,
:,
K. Alfonso,
A. Armatol,
C. Augier,
F. T. Avignone III,
O. Azzolini,
M. Balata,
I. C. Bandac,
A. S. Barabash,
G. Bari,
A. Barresi,
D. Baudin,
F. Bellini,
G. Benato,
V. Berest,
M. Beretta,
M. Bettelli,
M. Biassoni,
J. Billard,
V. Boldrini,
A. Branca,
C. Brofferio,
C. Bucci
, et al. (160 additional authors not shown)
Abstract:
An array of twelve 0.28 kg lithium molybdate (LMO) low-temperature bolometers equipped with 16 bolometric Ge light detectors, aiming at optimization of detector structure for CROSS and CUPID double-beta decay experiments, was constructed and tested in a low-background pulse-tube-based cryostat at the Canfranc underground laboratory in Spain. Performance of the scintillating bolometers was studied…
▽ More
An array of twelve 0.28 kg lithium molybdate (LMO) low-temperature bolometers equipped with 16 bolometric Ge light detectors, aiming at optimization of detector structure for CROSS and CUPID double-beta decay experiments, was constructed and tested in a low-background pulse-tube-based cryostat at the Canfranc underground laboratory in Spain. Performance of the scintillating bolometers was studied depending on the size of phonon NTD-Ge sensors glued to both LMO and Ge absorbers, shape of the Ge light detectors (circular vs. square, from two suppliers), in different light collection conditions (with and without reflector, with aluminum coated LMO crystal surface). The scintillating bolometer array was operated over 8 months in the low-background conditions that allowed to probe a very low, $μ$Bq/kg, level of the LMO crystals radioactive contamination by $^{228}$Th and $^{226}$Ra.
△ Less
Submitted 10 April, 2023;
originally announced April 2023.
-
Coherent radiation from a chain of charged particles on a circular orbit around a dielectric ball
Authors:
L. Sh. Grigoryan,
A. H. Mkrtchyan,
S. B. Dabagov,
A. A. Saharian,
V. R. Kocharyan,
V. Kh. Kotanjyan,
H. P. Harutyunyan,
H. F. Khachatryan
Abstract:
We investigate the electromagnetic radiation from a chain of relativistic charged particles uniformly rotating along equatorial orbit around a dielectric ball. For weak absorption of radiation in the ball material, at certain rotation frequency the radiation intensity becomes significantly higher than the corresponding value for a chain of charges rotating in free space or in a transparent medium…
▽ More
We investigate the electromagnetic radiation from a chain of relativistic charged particles uniformly rotating along equatorial orbit around a dielectric ball. For weak absorption of radiation in the ball material, at certain rotation frequency the radiation intensity becomes significantly higher than the corresponding value for a chain of charges rotating in free space or in a transparent medium with the same dielectric constant as that for the ball material. In the case of an equidistant distribution of charged particles along the orbit we determine the values of parameters of the problem for which the charges in the chain emit coherently. It is shown that the radiation intensity on a given harmonic increases in proportion to the square of the number of emitting charges. We also show that the relative shifts in the particles locations up to 10\% do not destroy the coherence properties of the radiation. It is demonstrated that the coherence effects may also dominate in the radiation intensity for chains with non-equidistant distributions of particles. The numerical results obtained for different dielectric balls have revealed the emitted radiation to be in the GHz/THz frequency ranges. The high-power radiation of the chain propagates in the angular range with respect to the rotation plane determined by the Cherenkov condition for the velocity of the chain projection onto the ball surface.
△ Less
Submitted 19 January, 2023; v1 submitted 15 June, 2022;
originally announced June 2022.
-
Toward CUPID-1T
Authors:
A. Armatol,
C. Augier,
F. T. Avignone III,
O. Azzolini,
M. Balata,
K. Ballen,
A. S. Barabash,
G. Bari,
A. Barresi,
D. Baudin,
F. Bellini,
G. Benato,
M. Beretta,
M. Bettelli,
M. Biassoni,
J. Billard,
V. Boldrini,
A. Branca,
C. Brofferio,
C. Bucci,
J. Camilleri,
C. Capelli,
S. Capelli,
L. Cappelli,
L. Cardani
, et al. (150 additional authors not shown)
Abstract:
Current experiments to search for broken lepton-number symmetry through the observation of neutrinoless double-beta decay ($0\mathrm{νββ}$) provide the most stringent limits on the Majorana nature of neutrinos and the effective Majorana neutrino mass ($m_{ββ}$). The next-generation experiments will focus on the sensitivity to the $0\mathrm{νββ}$ half-life of $\mathcal{O}(10^{27}$--$10^{28}$~years…
▽ More
Current experiments to search for broken lepton-number symmetry through the observation of neutrinoless double-beta decay ($0\mathrm{νββ}$) provide the most stringent limits on the Majorana nature of neutrinos and the effective Majorana neutrino mass ($m_{ββ}$). The next-generation experiments will focus on the sensitivity to the $0\mathrm{νββ}$ half-life of $\mathcal{O}(10^{27}$--$10^{28}$~years$)$ and $m_{ββ}\lesssim15$~meV, which would provide complete coverage of the so-called Inverted Ordering region of the neutrino mass parameter space. By taking advantage of recent technological breakthroughs, new, future calorimetric experiments at the 1-ton scale can increase the sensitivity by at least another order of magnitude, exploring the large fraction of the parameter space that corresponds to the Normal neutrino mass ordering. In case of a discovery, such experiments could provide important insights toward a new understanding of the mechanism of $0\mathrm{νββ}$.
We present here a series of projects underway that will provide advancements in background reduction, cryogenic readout, and physics searches beyond $0\mathrm{νββ}$, all moving toward the next-to-next generation CUPID-1T detector.
△ Less
Submitted 8 April, 2022; v1 submitted 16 March, 2022;
originally announced March 2022.
-
Optimization of the first CUPID detector module
Authors:
CUPID collaboration,
A. Armatol,
C. Augier,
F. T. Avignone III,
O. Azzolini,
M. Balata,
K. Ballen,
A. S. Barabash,
G. Bari,
A. Barresi,
D. Baudin,
F. Bellini,
G. Benato,
M. Beretta,
M. Bettelli,
M. Biassoni,
J. Billard,
V. Boldrini,
A. Branca,
C. Brofferio,
C. Bucci,
J. Camilleri,
C. Capelli,
S. Capelli,
L. Cappelli
, et al. (153 additional authors not shown)
Abstract:
CUPID will be a next generation experiment searching for the neutrinoless double $β$ decay, whose discovery would establish the Majorana nature of the neutrino. Based on the experience achieved with the CUORE experiment, presently taking data at LNGS, CUPID aims to reach a background free environment by means of scintillating Li$_{2}$$^{100}$MoO$_4$ crystals coupled to light detectors. Indeed, the…
▽ More
CUPID will be a next generation experiment searching for the neutrinoless double $β$ decay, whose discovery would establish the Majorana nature of the neutrino. Based on the experience achieved with the CUORE experiment, presently taking data at LNGS, CUPID aims to reach a background free environment by means of scintillating Li$_{2}$$^{100}$MoO$_4$ crystals coupled to light detectors. Indeed, the simultaneous heat and light detection allows us to reject the dominant background of $α$ particles, as proven by the CUPID-0 and CUPID-Mo demonstrators. In this work we present the results of the first test of the CUPID baseline module. In particular, we propose a new optimized detector structure and light sensors design to enhance the engineering and the light collection, respectively. We characterized the heat detectors, achieving an energy resolution of (5.9 $\pm$ 0.2) keV FWHM at the $Q$-value of $^{100}$Mo (about 3034 keV). We studied the light collection of the baseline CUPID design with respect to an alternative configuration which features gravity-assisted light detectors' mounting. In both cases we obtained an improvement in the light collection with respect to past measures and we validated the particle identification capability of the detector, which ensures an $α$ particle rejection higher than 99.9%, fully satisfying the requirements for CUPID.
△ Less
Submitted 13 February, 2022;
originally announced February 2022.
-
On channeling of charged particles in a single dielectric capillary
Authors:
S. B. Dabagov,
A. V. Dik
Abstract:
We analytically analyse the motion of a nonrelativistic charged particle in a cylindrical single capillary. The effective potential for interaction of a charged particle with the inner surface of a capillary is derived as a sum of the averaged atomic potential of the capillary wall surface and the induced potential defined by collective surface excitations. We have shown that under certain conditi…
▽ More
We analytically analyse the motion of a nonrelativistic charged particle in a cylindrical single capillary. The effective potential for interaction of a charged particle with the inner surface of a capillary is derived as a sum of the averaged atomic potential of the capillary wall surface and the induced potential defined by collective surface excitations. We have shown that under certain conditions this potential becomes attractive and may hold a particle in a bound state due to the surface excitations that defines a so-called surface channeling regime of motion. For the first time we have evaluated the induced potential revealing two limits to form either a well or a barrier that are delineated by the ratio of the insulator plasmon frequency to the frequency defined by the particle motion in a capillary.
△ Less
Submitted 13 September, 2021; v1 submitted 8 September, 2021;
originally announced September 2021.
-
Measurement of the Positive Muon Anomalous Magnetic Moment to 0.46 ppm
Authors:
B. Abi,
T. Albahri,
S. Al-Kilani,
D. Allspach,
L. P. Alonzi,
A. Anastasi,
A. Anisenkov,
F. Azfar,
K. Badgley,
S. Baeßler,
I. Bailey,
V. A. Baranov,
E. Barlas-Yucel,
T. Barrett,
E. Barzi,
A. Basti,
F. Bedeschi,
A. Behnke,
M. Berz,
M. Bhattacharya,
H. P. Binney,
R. Bjorkquist,
P. Bloom,
J. Bono,
E. Bottalico
, et al. (212 additional authors not shown)
Abstract:
We present the first results of the Fermilab Muon g-2 Experiment for the positive muon magnetic anomaly $a_μ\equiv (g_μ-2)/2$. The anomaly is determined from the precision measurements of two angular frequencies. Intensity variation of high-energy positrons from muon decays directly encodes the difference frequency $ω_a$ between the spin-precession and cyclotron frequencies for polarized muons in…
▽ More
We present the first results of the Fermilab Muon g-2 Experiment for the positive muon magnetic anomaly $a_μ\equiv (g_μ-2)/2$. The anomaly is determined from the precision measurements of two angular frequencies. Intensity variation of high-energy positrons from muon decays directly encodes the difference frequency $ω_a$ between the spin-precession and cyclotron frequencies for polarized muons in a magnetic storage ring. The storage ring magnetic field is measured using nuclear magnetic resonance probes calibrated in terms of the equivalent proton spin precession frequency ${\tildeω'^{}_p}$ in a spherical water sample at 34.7$^{\circ}$C. The ratio $ω_a / {\tildeω'^{}_p}$, together with known fundamental constants, determines $a_μ({\rm FNAL}) = 116\,592\,040(54)\times 10^{-11}$ (0.46\,ppm). The result is 3.3 standard deviations greater than the standard model prediction and is in excellent agreement with the previous Brookhaven National Laboratory (BNL) E821 measurement. After combination with previous measurements of both $μ^+$ and $μ^-$, the new experimental average of $a_μ({\rm Exp}) = 116\,592\,061(41)\times 10^{-11}$ (0.35\,ppm) increases the tension between experiment and theory to 4.2 standard deviations
△ Less
Submitted 7 April, 2021;
originally announced April 2021.
-
Measurement of the anomalous precession frequency of the muon in the Fermilab Muon g-2 experiment
Authors:
T. Albahri,
A. Anastasi,
A. Anisenkov,
K. Badgley,
S. Baeßler,
I. Bailey,
V. A. Baranov,
E. Barlas-Yucel,
T. Barrett,
A. Basti,
F. Bedeschi,
M. Berz,
M. Bhattacharya,
H. P. Binney,
P. Bloom,
J. Bono,
E. Bottalico,
T. Bowcock,
G. Cantatore,
R. M. Carey,
B. C. K. Casey,
D. Cauz,
R. Chakraborty,
S. P. Chang,
A. Chapelain
, et al. (153 additional authors not shown)
Abstract:
The Muon g-2 Experiment at Fermi National Accelerator Laboratory (FNAL) has measured the muon anomalous precession frequency $ω_a$ to an uncertainty of 434 parts per billion (ppb), statistical, and 56 ppb, systematic, with data collected in four storage ring configurations during its first physics run in 2018. When combined with a precision measurement of the magnetic field of the experiment's muo…
▽ More
The Muon g-2 Experiment at Fermi National Accelerator Laboratory (FNAL) has measured the muon anomalous precession frequency $ω_a$ to an uncertainty of 434 parts per billion (ppb), statistical, and 56 ppb, systematic, with data collected in four storage ring configurations during its first physics run in 2018. When combined with a precision measurement of the magnetic field of the experiment's muon storage ring, the precession frequency measurement determines a muon magnetic anomaly of $a_μ({\rm FNAL}) = 116\,592\,040(54) \times 10^{-11}$ (0.46 ppm). This article describes the multiple techniques employed in the reconstruction, analysis and fitting of the data to measure the precession frequency. It also presents the averaging of the results from the eleven separate determinations of ω_a, and the systematic uncertainties on the result.
△ Less
Submitted 7 April, 2021;
originally announced April 2021.
-
Beam dynamics corrections to the Run-1 measurement of the muon anomalous magnetic moment at Fermilab
Authors:
T. Albahri,
A. Anastasi,
K. Badgley,
S. Baeßler,
I. Bailey,
V. A. Baranov,
E. Barlas-Yucel,
T. Barrett,
F. Bedeschi,
M. Berz,
M. Bhattacharya,
H. P. Binney,
P. Bloom,
J. Bono,
E. Bottalico,
T. Bowcock,
G. Cantatore,
R. M. Carey,
B. C. K. Casey,
D. Cauz,
R. Chakraborty,
S. P. Chang,
A. Chapelain,
S. Charity,
R. Chislett
, et al. (152 additional authors not shown)
Abstract:
This paper presents the beam dynamics systematic corrections and their uncertainties for the Run-1 data set of the Fermilab Muon g-2 Experiment. Two corrections to the measured muon precession frequency $ω_a^m$ are associated with well-known effects owing to the use of electrostatic quadrupole (ESQ) vertical focusing in the storage ring. An average vertically oriented motional magnetic field is fe…
▽ More
This paper presents the beam dynamics systematic corrections and their uncertainties for the Run-1 data set of the Fermilab Muon g-2 Experiment. Two corrections to the measured muon precession frequency $ω_a^m$ are associated with well-known effects owing to the use of electrostatic quadrupole (ESQ) vertical focusing in the storage ring. An average vertically oriented motional magnetic field is felt by relativistic muons passing transversely through the radial electric field components created by the ESQ system. The correction depends on the stored momentum distribution and the tunes of the ring, which has relatively weak vertical focusing. Vertical betatron motions imply that the muons do not orbit the ring in a plane exactly orthogonal to the vertical magnetic field direction. A correction is necessary to account for an average pitch angle associated with their trajectories. A third small correction is necessary because muons that escape the ring during the storage time are slightly biased in initial spin phase compared to the parent distribution. Finally, because two high-voltage resistors in the ESQ network had longer than designed RC time constants, the vertical and horizontal centroids and envelopes of the stored muon beam drifted slightly, but coherently, during each storage ring fill. This led to the discovery of an important phase-acceptance relationship that requires a correction. The sum of the corrections to $ω_a^m$ is 0.50 $\pm$ 0.09 ppm; the uncertainty is small compared to the 0.43 ppm statistical precision of $ω_a^m$.
△ Less
Submitted 23 April, 2021; v1 submitted 7 April, 2021;
originally announced April 2021.
-
Magnetic Field Measurement and Analysis for the Muon g-2 Experiment at Fermilab
Authors:
T. Albahri,
A. Anastasi,
K. Badgley,
S. Baeßler,
I. Bailey,
V. A. Baranov,
E. Barlas-Yucel,
T. Barrett,
F. Bedeschi,
M. Berz,
M. Bhattacharya,
H. P. Binney,
P. Bloom,
J. Bono,
E. Bottalico,
T. Bowcock,
G. Cantatore,
R. M. Carey,
B. C. K. Casey,
D. Cauz,
R. Chakraborty,
S. P. Chang,
A. Chapelain,
S. Charity,
R. Chislett
, et al. (148 additional authors not shown)
Abstract:
The Fermi National Accelerator Laboratory has measured the anomalous precession frequency $a^{}_μ= (g^{}_μ-2)/2$ of the muon to a combined precision of 0.46 parts per million with data collected during its first physics run in 2018. This paper documents the measurement of the magnetic field in the muon storage ring. The magnetic field is monitored by nuclear magnetic resonance systems and calibrat…
▽ More
The Fermi National Accelerator Laboratory has measured the anomalous precession frequency $a^{}_μ= (g^{}_μ-2)/2$ of the muon to a combined precision of 0.46 parts per million with data collected during its first physics run in 2018. This paper documents the measurement of the magnetic field in the muon storage ring. The magnetic field is monitored by nuclear magnetic resonance systems and calibrated in terms of the equivalent proton spin precession frequency in a spherical water sample at 34.7$^\circ$C. The measured field is weighted by the muon distribution resulting in $\tildeω'^{}_p$, the denominator in the ratio $ω^{}_a$/$\tildeω'^{}_p$ that together with known fundamental constants yields $a^{}_μ$. The reported uncertainty on $\tildeω'^{}_p$ for the Run-1 data set is 114 ppb consisting of uncertainty contributions from frequency extraction, calibration, map**, tracking, and averaging of 56 ppb, and contributions from fast transient fields of 99 ppb.
△ Less
Submitted 17 June, 2022; v1 submitted 7 April, 2021;
originally announced April 2021.
-
The laser-based gain monitoring system of the calorimeters in the Muon $g-2$ experiment at Fermilab
Authors:
A. Anastasi,
A. Basti,
F. Bedeschi,
A. Boiano,
E. Bottalico,
G. Cantatore,
D. Cauz,
A. T. Chapelain,
G. Corradi,
S. Dabagov,
S. Di Falco,
P. Di Meo,
G. Di Sciascio,
R. Di Stefano,
S. Donati,
A. Driutti,
C. Ferrari,
A. T. Fienberg,
A. Fioretti,
C. Gabbanini,
L. K. Gibbons,
A. Gioiosa,
P. Girotti,
D. Hampai,
J. B. Hempstead
, et al. (19 additional authors not shown)
Abstract:
The Muon $g-2$ experiment, E989, is currently taking data at Fermilab with the aim of reducing the experimental error on the muon anomaly by a factor of four and possibly clarifying the current discrepancy with the theoretical prediction. A central component of this four-fold improvement in precision is the laser calibration system of the calorimeters, which has to monitor the gain variations of t…
▽ More
The Muon $g-2$ experiment, E989, is currently taking data at Fermilab with the aim of reducing the experimental error on the muon anomaly by a factor of four and possibly clarifying the current discrepancy with the theoretical prediction. A central component of this four-fold improvement in precision is the laser calibration system of the calorimeters, which has to monitor the gain variations of the photo-sensors with a 0.04\% precision on the short-term ($\sim 1\,$ms). This is about one order of magnitude better than what has ever been achieved for the calibration of a particle physics calorimeter. The system is designed to monitor also long-term gain variations, mostly due to temperature effects, with a precision below the per mille level. This article reviews the design, the implementation and the performance of the Muon $g-2$ laser calibration system, showing how the experimental requirements have been met.
△ Less
Submitted 28 November, 2019; v1 submitted 19 June, 2019;
originally announced June 2019.
-
Design study of a photon beamline for a soft X-ray FEL driven by high gradient acceleration at EuPRAXIA@SPARC_LAB
Authors:
Fabio Villa,
Alessandro Cianchi,
Marcello Coreno,
Sultan Dabagov,
Augusto Marcelli,
Velia Minicozzi,
Silvia Morante,
Francesco Stellato
Abstract:
We are proposing a facility based on high gradient acceleration via x-band RF structures and plasma acceleration. We plan to reach an electron energy of the order of 1 GeV, suitable to drive a Free Electron Laser for applications in the so called "water window" (2 - 4 nm). A conceptual design of the beamline, from the photon beam from the undulators to the user experimental chamber, mainly focusin…
▽ More
We are proposing a facility based on high gradient acceleration via x-band RF structures and plasma acceleration. We plan to reach an electron energy of the order of 1 GeV, suitable to drive a Free Electron Laser for applications in the so called "water window" (2 - 4 nm). A conceptual design of the beamline, from the photon beam from the undulators to the user experimental chamber, mainly focusing on diagnostic, manipulation and transport of the radiation is presented and discussed. We also briefly outline a user end station for coherent imaging, laser ablation and pump-probe experiments.
△ Less
Submitted 15 February, 2018;
originally announced February 2018.
-
EuPRAXIA@SPARC_LAB Design study towards a compact FEL facility at LNF
Authors:
M. Ferrario,
D. Alesini,
M. P. Anania,
M. Artioli,
A. Bacci,
S. Bartocci,
R. Bedogni,
M. Bellaveglia,
A. Biagioni,
F. Bisesto,
F. Brandi,
E. Brentegani,
F. Broggi,
B. Buonomo,
P. L. Campana,
G. Campogiani,
C. Cannaos,
S. Cantarella,
F. Cardelli,
M. Carpanese,
M. Castellano,
G. Castorina,
N. Catalan Lasheras,
E. Chiadroni,
A. Cianchi
, et al. (95 additional authors not shown)
Abstract:
On the wake of the results obtained so far at the SPARC\_LAB test-facility at the Laboratori Nazionali di Frascati (Italy), we are currently investigating the possibility to design and build a new multi-disciplinary user-facility, equipped with a soft X-ray Free Electron Laser (FEL) driven by a $\sim$1 GeV high brightness linac based on plasma accelerator modules. This design study is performed in…
▽ More
On the wake of the results obtained so far at the SPARC\_LAB test-facility at the Laboratori Nazionali di Frascati (Italy), we are currently investigating the possibility to design and build a new multi-disciplinary user-facility, equipped with a soft X-ray Free Electron Laser (FEL) driven by a $\sim$1 GeV high brightness linac based on plasma accelerator modules. This design study is performed in synergy with the EuPRAXIA design study. In this paper we report about the recent progresses in the on going design study of the new facility.
△ Less
Submitted 26 January, 2018;
originally announced January 2018.
-
Geant4 simulations of the lead fluoride calorimeter
Authors:
A. A. Savchenko,
A. A. Tishchenko,
S. B. Dabagov,
A. Anastasi,
G. Venanzoni,
M. N. Strikhanov
Abstract:
In this paper we simulate the emission by charged particles in complex structures with help of Geant4. We take into account Cherenkov radiation, transition radiation, bremsstrahlung, pair production and other accompanying processes. As an application we investigate the full size electromagnetic calorimeter for the muon g-2 experiment at Fermilab. A calorimeter module (24 are expected in the experi…
▽ More
In this paper we simulate the emission by charged particles in complex structures with help of Geant4. We take into account Cherenkov radiation, transition radiation, bremsstrahlung, pair production and other accompanying processes. As an application we investigate the full size electromagnetic calorimeter for the muon g-2 experiment at Fermilab. A calorimeter module (24 are expected in the experiment) consists of a Delrin front panel for installation of the laser calibration system, 54 PbF2 Cherenkov crystals wrapped by the black Millipore paper, and silicon photo-multiplier sensors. We report here on a simulation of radiation from positrons passing through the calorimeter system. We carry out the simulation using Geant4 toolkit, which provides a complete set of tools for all areas of detector simulation: geometry, tracking, detector response, run, event and track management, and visualization. We consider Cherenkov photons expansion when a positron moves down through the calorimeter at the arbitrary angle of incidence. Both spectral and angular distributions of Cherenkov optical photons in different parts of the calorimeter system have been evaluated as well as the transition radiation and pre-shower distributions from the panel and from the Al vacuum chamber of the storage ring. (The paper is in progress).
△ Less
Submitted 10 December, 2016; v1 submitted 30 November, 2016;
originally announced November 2016.
-
Electron beam test of key elements of the laser-based calibration system for the muon $g$ $-$ $2$ experiment
Authors:
A. Anastasi,
A. Basti,
F. Bedeschi,
M. Bartolini,
G. Cantatore,
D. Cauz,
G. Corradi,
S. Dabagov,
G. DI Sciascio,
R. Di Stefano,
A. Driutti,
O. Escalante,
C. Ferrari,
A. T. Fienberg,
A. Fioretti,
C. Gabbanini,
A. Gioiosa,
D. Hampai,
D. W. Hertzog,
M. Iacovacci,
M. Karuza,
J. Kaspar,
A. Liedl,
A. Lusiani,
F. Marignetti
, et al. (8 additional authors not shown)
Abstract:
We report the test of many of the key elements of the laser-based calibration system for muon g - 2 experiment E989 at Fermilab. The test was performed at the Laboratori Nazionali di Frascati's Beam Test Facility using a 450 MeV electron beam im**ing on a small subset of the final g - 2 lead-fluoride crystal calorimeter system. The calibration system was configured as planned for the E989 experi…
▽ More
We report the test of many of the key elements of the laser-based calibration system for muon g - 2 experiment E989 at Fermilab. The test was performed at the Laboratori Nazionali di Frascati's Beam Test Facility using a 450 MeV electron beam im**ing on a small subset of the final g - 2 lead-fluoride crystal calorimeter system. The calibration system was configured as planned for the E989 experiment and uses the same type of laser and most of the final optical elements. We show results regarding the calorimeter's response calibration, the maximum equivalent electron energy which can be provided by the laser and the stability of the calibration system components.
△ Less
Submitted 11 October, 2016;
originally announced October 2016.
-
Test of candidate light distributors for the muon (g$-$2) laser calibration system
Authors:
A. Anastasi,
D. Babusci,
F. Baffigi,
G. Cantatore,
D. Cauz,
G. Corradi,
S. Dabagov,
G. Di Sciascio,
R. Di Stefano,
C. Ferrari,
A. T. Fienberg,
A. Fioretti,
L. Fulgentini,
C. Gabbanini,
L. A. Gizzi,
D. Hampai,
D. W. Hertzog,
M. Iacovacci,
M. Karuza,
J. Kaspar,
P. Koester,
L. Labate,
S. Mastroianni,
D. Moricciani,
G. Pauletta
, et al. (2 additional authors not shown)
Abstract:
The new muon (g-2) experiment E989 at Fermilab will be equipped with a laser calibration system for all the 1296 channels of the calorimeters. An integrating sphere and an alternative system based on an engineered diffuser have been considered as possible light distributors for the experiment. We present here a detailed comparison of the two based on temporal response, spatial uniformity, transmit…
▽ More
The new muon (g-2) experiment E989 at Fermilab will be equipped with a laser calibration system for all the 1296 channels of the calorimeters. An integrating sphere and an alternative system based on an engineered diffuser have been considered as possible light distributors for the experiment. We present here a detailed comparison of the two based on temporal response, spatial uniformity, transmittance and time stability.
△ Less
Submitted 1 April, 2015;
originally announced April 2015.
-
Muon (g-2) Technical Design Report
Authors:
J. Grange,
V. Guarino,
P. Winter,
K. Wood,
H. Zhao,
R. M. Carey,
D. Gastler,
E. Hazen,
N. Kinnaird,
J. P. Miller,
J. Mott,
B. L. Roberts,
J. Benante,
J. Crnkovic,
W. M. Morse,
H. Sayed,
V. Tishchenko,
V. P. Druzhinin,
B. I. Khazin,
I. A. Koop,
I. Logashenko,
Y. M. Shatunov,
E. Solodov,
M. Korostelev,
D. Newton
, et al. (176 additional authors not shown)
Abstract:
The Muon (g-2) Experiment, E989 at Fermilab, will measure the muon anomalous magnetic moment a factor-of-four more precisely than was done in E821 at the Brookhaven National Laboratory AGS. The E821 result appears to be greater than the Standard-Model prediction by more than three standard deviations. When combined with expected improvement in the Standard-Model hadronic contributions, E989 should…
▽ More
The Muon (g-2) Experiment, E989 at Fermilab, will measure the muon anomalous magnetic moment a factor-of-four more precisely than was done in E821 at the Brookhaven National Laboratory AGS. The E821 result appears to be greater than the Standard-Model prediction by more than three standard deviations. When combined with expected improvement in the Standard-Model hadronic contributions, E989 should be able to determine definitively whether or not the E821 result is evidence for physics beyond the Standard Model. After a review of the physics motivation and the basic technique, which will use the muon storage ring built at BNL and now relocated to Fermilab, the design of the new experiment is presented. This document was created in partial fulfillment of the requirements necessary to obtain DOE CD-2/3 approval.
△ Less
Submitted 11 May, 2018; v1 submitted 27 January, 2015;
originally announced January 2015.
-
Study of the single cluster response of a helium-isobutane drift chamber prototype using 8 keV X-rays
Authors:
G. Cavoto,
S. Dabagov,
D. Hampai,
G. Piredda,
F. Renga,
E. Ripiccini,
C. Voena
Abstract:
The identification of single clusters in the electronic signals produced by ionizing particles within a drift chamber is expected to significantly improve the performances of this kind of detectors in terms of particle identification capabilities and space resolution. In order to develop refined cluster recognition algorithms, it is essential to measure the response of the chamber and its electron…
▽ More
The identification of single clusters in the electronic signals produced by ionizing particles within a drift chamber is expected to significantly improve the performances of this kind of detectors in terms of particle identification capabilities and space resolution. In order to develop refined cluster recognition algorithms, it is essential to measure the response of the chamber and its electronics to single ionization clusters. This can be done by irradiating the chamber with X-rays. We report here on the studies performed on a drift chamber prototype for the MEG-II experiment at the X-ray facility of the INFN Frascati's National Laboratories "XLab Frascati". The prototype is operated with a helium-isobutane mixture and instrumented with high bandwidth custom pre-amplifiers. The results of this study have been used to develop an innovative method for cluster recognition, based on the Wiener filter technique. As a side measurement, we also performed a study of the gas gain in a configuration which is similar to that of the MEG-II experiment.
△ Less
Submitted 31 October, 2014;
originally announced October 2014.
-
Diffraction Radiation of Electron Bunches for One- and Two Slit Systems
Authors:
V. Shpakov,
S. Dabagov
Abstract:
New research in acceleration physics leads to growing up the power of charged particles bunches. Existed methods based on interaction of detection devices with bunches do not satisfy our need, because of the fact that new high intensity bunches can damage this devices. Moreover, these methods do not allow analyzing the bunches in real time. Recently new technique based on ODRI (optical diffraction…
▽ More
New research in acceleration physics leads to growing up the power of charged particles bunches. Existed methods based on interaction of detection devices with bunches do not satisfy our need, because of the fact that new high intensity bunches can damage this devices. Moreover, these methods do not allow analyzing the bunches in real time. Recently new technique based on ODRI (optical diffraction radiation interference) by a bunch at its propagation through the slit was proposed. In this work the results of theoretical simulations on diffraction radiation, in particular ODRI, by electrons for various slit systems as well as the comparison with the DESY experimental data are presented.
△ Less
Submitted 25 August, 2014;
originally announced August 2014.
-
Channeling of Electrons in a Crossed Laser Field
Authors:
Sultan B. Dabagov,
Alexey V. Dik,
Evgenii N. Frolov
Abstract:
In this article a new analytical description of the effective interaction potential for a charged particle in the field of two interfering laser beams is presented. The potential dependence on the lasers intensities, orientation and parameters of the particle entering the considered system is analyzed. It is shown for the case of arbitrary lasers crossing angle that for different values of project…
▽ More
In this article a new analytical description of the effective interaction potential for a charged particle in the field of two interfering laser beams is presented. The potential dependence on the lasers intensities, orientation and parameters of the particle entering the considered system is analyzed. It is shown for the case of arbitrary lasers crossing angle that for different values of projectile velocity the attracting potential becomes a scattering one so that the channel axes and borders interchange each other. In addition the projectile radiation spectral distribution is given and general estimations on the expected beam radiation yield are outlined.
△ Less
Submitted 10 March, 2015; v1 submitted 12 April, 2014;
originally announced April 2014.
-
Deflection of proton beams by crystal miscut surface
Authors:
A. A. Babaev,
G. Cavoto,
S. B. Dabagov
Abstract:
First computer experiment results on proton beam deflection by the crystal miscut surface are presented. The phenomenology of proton channeling and quasichanneling has been applied to describe new features of the beam deflection. The analysis predicts efficient beam deflection by the acute crystal end due to repelling miscut potential.
First computer experiment results on proton beam deflection by the crystal miscut surface are presented. The phenomenology of proton channeling and quasichanneling has been applied to describe new features of the beam deflection. The analysis predicts efficient beam deflection by the acute crystal end due to repelling miscut potential.
△ Less
Submitted 21 January, 2014;
originally announced January 2014.
-
IRIDE White Book, An Interdisciplinary Research Infrastructure based on Dual Electron linacs&lasers
Authors:
D. Alesini,
M. Alessandroni,
M. P. Anania,
S. Andreas,
M. Angelone,
A. Arcovito,
F. Arnesano,
M. Artioli,
L. Avaldi,
D. Babusci,
A. Bacci,
A. Balerna,
S. Bartalucci,
R. Bedogni,
M. Bellaveglia,
F. Bencivenga,
M. Benfatto,
S. Biedron,
V. Bocci,
M. Bolognesi,
P. Bolognesi,
R. Boni,
R. Bonifacio,
M. Boscolo,
F. Boscherini
, et al. (189 additional authors not shown)
Abstract:
This report describes the scientific aims and potentials as well as the preliminary technical design of IRIDE, an innovative tool for multi-disciplinary investigations in a wide field of scientific, technological and industrial applications. IRIDE will be a high intensity 'particle factory', based on a combination of a high duty cycle radio-frequency superconducting electron linac and of high ener…
▽ More
This report describes the scientific aims and potentials as well as the preliminary technical design of IRIDE, an innovative tool for multi-disciplinary investigations in a wide field of scientific, technological and industrial applications. IRIDE will be a high intensity 'particle factory', based on a combination of a high duty cycle radio-frequency superconducting electron linac and of high energy lasers. Conceived to provide unique research possibilities for particle physics, for condensed matter physics, chemistry and material science, for structural biology and industrial applications, IRIDE will open completely new research possibilities and advance our knowledge in many branches of science and technology. IRIDE will contribute to open new avenues of discoveries and to address most important riddles: What does matter consist of? What is the structure of proteins that have a fundamental role in life processes? What can we learn from protein structure to improve the treatment of diseases and to design more efficient drugs? But also how does an electronic chip behave under the effect of radiations? How can the heat flow in a large heat exchanger be optimized? The scientific potential of IRIDE is far reaching and justifies the construction of such a large facility in Italy in synergy with the national research institutes and companies and in the framework of the European and international research. It will impact also on R&D work for ILC, FEL, and will be complementarity to other large scale accelerator projects. IRIDE is also intended to be realized in subsequent stages of development depending on the assigned priorities.
△ Less
Submitted 30 July, 2013;
originally announced July 2013.
-
The UA9 experimental layout
Authors:
W. Scandale,
G. Arduini,
R. Assmann,
C. Bracco,
F. Cerutti,
J. Christiansen,
S. Gilardoni,
E. Laface,
R. Losito,
A. Masi,
E. Metral,
D. Mirarchi,
S. Montesano,
V. Previtali,
S. Redaelli,
G. Valentino,
P. Schoofs,
G. Smirnov,
L. Tlustos,
E. Bagli,
S. Baricordi,
P. Dalpiaz,
V. Guidi,
A. Mazzolari,
D. Vincenzi
, et al. (36 additional authors not shown)
Abstract:
The UA9 experimental equipment was installed in the CERN-SPS in March '09 with the aim of investigating crystal assisted collimation in coasting mode.
Its basic layout comprises silicon bent crystals acting as primary collimators mounted inside two vacuum vessels. A movable 60 cm long block of tungsten located downstream at about 90 degrees phase advance intercepts the deflected beam.
Scintill…
▽ More
The UA9 experimental equipment was installed in the CERN-SPS in March '09 with the aim of investigating crystal assisted collimation in coasting mode.
Its basic layout comprises silicon bent crystals acting as primary collimators mounted inside two vacuum vessels. A movable 60 cm long block of tungsten located downstream at about 90 degrees phase advance intercepts the deflected beam.
Scintillators, Gas Electron Multiplier chambers and other beam loss monitors measure nuclear loss rates induced by the interaction of the beam halo in the crystal. Roman pots are installed in the path of the deflected particles and are equipped with a Medipix detector to reconstruct the transverse distribution of the im**ing beam. Finally UA9 takes advantage of an LHC-collimator prototype installed close to the Roman pot to help in setting the beam conditions and to analyze the efficiency to deflect the beam. This paper describes in details the hardware installed to study the crystal collimation during 2010.
△ Less
Submitted 29 June, 2011;
originally announced June 2011.
-
On X-Ray Waveguiding in Nanochannels: Channeling Formalism
Authors:
S. B. Dabagov
Abstract:
The question on X-ray extreme focusing (smallest reachable spot size) brings us to the idea for using the wave features of X-ray propagation in media. As known, wave features are revealed at propagation in ultra-narrow collimators as well as at glancing reflection from smooth flat and/or strongly curved surfaces. All these phenomena can be described within the general formalism of X-ray channeli…
▽ More
The question on X-ray extreme focusing (smallest reachable spot size) brings us to the idea for using the wave features of X-ray propagation in media. As known, wave features are revealed at propagation in ultra-narrow collimators as well as at glancing reflection from smooth flat and/or strongly curved surfaces. All these phenomena can be described within the general formalism of X-ray channeling.
△ Less
Submitted 20 November, 2006;
originally announced November 2006.
-
X-ray propagation through hollow channel: PolyCAD - a ray tracing code (1)
Authors:
D. Hampai,
S. B. Dabagov,
G. Cappuccio,
G. Cibin
Abstract:
A new CAD program, PolyCAD, designed for X-ray photon tracing in polycapillary optics is described. To understand the PolyCAD code and its results, the theoretical basis of X-ray transmission by a single cylindrical channel (monocapillary) is discussed first. Then the simplest cases of cylindrically and conically shaped polycapillary optics are examined. PolyCAD allows any type of X-ray source t…
▽ More
A new CAD program, PolyCAD, designed for X-ray photon tracing in polycapillary optics is described. To understand the PolyCAD code and its results, the theoretical basis of X-ray transmission by a single cylindrical channel (monocapillary) is discussed first. Then the simplest cases of cylindrically and conically shaped polycapillary optics are examined. PolyCAD allows any type of X-ray source to be used: an X-ray tube of finite beam dimensions or an astrophysical object can be simulated in combination with the polycapillary optics. The radiation distribution images formed on a screen located at various focal distances are discussed. The good agreement of some of the PolyCAD results with those reported in earlier papers validate the code. This is the first paper of a series dedicated to the development of an exhaustive CAD program, work is in progress to develop the code to include other polycapillary-optics shapes, such as semi-lenses and full-lenses.
△ Less
Submitted 8 February, 2005;
originally announced February 2005.
-
Anisotropy of x-ray scattering in aligned nanotube structures
Authors:
A. V. Okotrub,
S. B. Dabagov,
A. G. Kudashev,
A. V. Gusel'nikov,
L. G. Bulusheva,
A. Grilli
Abstract:
Effects of orientational x-ray scattering have been experimentally examined in a film of vertically aligned multiwall carbon nanotubes (CNs). Additional contribution to the x-ray fluorescence intensity was revealed at angles close to the film normal. Theoretical considerations suggest the intensity enhancement to be caused by propagation of C K$_α$-radiation mainly along the channels of CNs.
Effects of orientational x-ray scattering have been experimentally examined in a film of vertically aligned multiwall carbon nanotubes (CNs). Additional contribution to the x-ray fluorescence intensity was revealed at angles close to the film normal. Theoretical considerations suggest the intensity enhancement to be caused by propagation of C K$_α$-radiation mainly along the channels of CNs.
△ Less
Submitted 16 June, 2004;
originally announced June 2004.
-
On X-Ray Channeling in mu- and n-capillaries
Authors:
S. Bellucci,
S. B. Dabagov
Abstract:
In this work X-ray propagation in micro- and nano-size capillaries has been considered in the frame of a simple unified wave theory. It is shown that the diminishing of the channel sizes completely changes the mode of beam transportation, namely, we obtain the transformation of surface channeling in microcapillaries to bulk channeling in nanocapillaries (nanotubes).
In this work X-ray propagation in micro- and nano-size capillaries has been considered in the frame of a simple unified wave theory. It is shown that the diminishing of the channel sizes completely changes the mode of beam transportation, namely, we obtain the transformation of surface channeling in microcapillaries to bulk channeling in nanocapillaries (nanotubes).
△ Less
Submitted 4 September, 2002;
originally announced September 2002.
-
Experimental Study For The Feasibility Of A Crystalline Undulator
Authors:
S. Bellucci,
S. Bini,
V. M. Biryukov,
Yu. A. Chesnokov,
S. Dabagov,
G. Giannini,
V. Guidi,
Yu. M. Ivanov,
V. I. Kotov,
V. A. Maisheev,
C. Malagu,
G. Martinelli,
A. A. Petrunin,
V. V. Skorobogatov,
M. Stefancich,
D. Vincenzi
Abstract:
We present an idea for creation of a crystalline undulator and report its first realization. One face of a silicon crystal was given periodic micro-scratches (trenches) by means of a diamond blade. The X-ray tests of the crystal deformation due to given periodic pattern of surface scratches have shown that a sinusoidal shape is observed on both the scratched surface and the opposite (unscratched…
▽ More
We present an idea for creation of a crystalline undulator and report its first realization. One face of a silicon crystal was given periodic micro-scratches (trenches) by means of a diamond blade. The X-ray tests of the crystal deformation due to given periodic pattern of surface scratches have shown that a sinusoidal shape is observed on both the scratched surface and the opposite (unscratched) face of the crystal, that is, a periodic sinusoidal deformation goes through the bulk of the crystal. This opens up the possibility for experiments with high-energy particles channeled in crystalline undulator, a novel compact source of radiation.
△ Less
Submitted 7 August, 2002;
originally announced August 2002.