Skip to main content

Showing 1–4 of 4 results for author: Düdder, A

.
  1. Design, Construction and Performance Tests of a Prototype MicroMegas Chamber with Two Readout Planes in a Common Gas Volume

    Authors: Bernard Brickwedde, Andreas Düdder, Matthias Schott, Eda Yildirim

    Abstract: In this paper, the design and the performance of a prototype detector based on MicroMegas technology with two detection planes in a common gas volume is discussed. The detector is suited for the forward region of LHC detectors, addressing the high-rate environment and limited available space. Each detection plane has an active area of 9x9 cm^2 with a two-dimensional strip readout and is separated… ▽ More

    Submitted 29 October, 2016; originally announced October 2016.

    Comments: 12 pages, 10 figures

  2. Construction of two large-size four-plane micromegas detectors

    Authors: Michele Bianco, Hans Danielsson, Jordan Degrange, Rui De Oliveira, Andreas Düdder, Edoardo Farina, Fabian Kuger, Paolo Iengo, Francisco Perez Gomez, Tai-Hua Lin, Matthias Schott, Givi Sekhniaidze, Federico Sforza, Ourania Sidiropoulou, Chrysostomos Valderanis, Maurice Vergain, Jörg Wotschack

    Abstract: We report on the construction and initial performance studies of two micromegas detector quadruplets with an area of 0.5 m$^2$. They serve as prototypes for the planned upgrade project of the ATLAS muon system. Their design is based on the resistive-strip technology and thus renders the detectors spark tolerant. Each quadruplet comprises four detection layers with 1024 readout strips and a strip p… ▽ More

    Submitted 12 November, 2015; originally announced November 2015.

    Comments: 26 pages, 25 figures

  3. arXiv:1506.01164  [pdf, other

    physics.ins-det

    Development and Study of a Micromegas Pad-Detector for High Rate Applications

    Authors: Tai-Hua Lin, Andreas Düdder, Matthias Schott, Chrysostomos Valderanis

    Abstract: In this paper, the design and the performance of two prototype detectors based on Micromegas technology with a pad readout geometry is discussed. In addition, two alternative implementations of a spark-resistent protection layer on top of the readout pads have been tested to optimize the charge-up behavior of the detector under high rates. The prototype detectors consist of 500 pads with a size of… ▽ More

    Submitted 3 June, 2015; originally announced June 2015.

    Comments: 12 page, 8 figures

  4. Signal Characteristics of a Resistive-Strip Micromegas Detector with an Integrated Two-Dimensional Readout

    Authors: Tai-Hua Lin, Andreas Düdder, Matthias Schott, Chrysostomos Valderanis, Laura Wehner, Robert Westenberger

    Abstract: In recent years, micropattern gaseous detectors, which comprise a two-dimensional readout structure within one PCB layer, received significant attention in the development of precision and cost-effective tracking detectors in medium and high energy physics experiments. In this article, we present for the first time a systematic performance study of the signal characteristics of a resistive strip m… ▽ More

    Submitted 26 June, 2014; originally announced June 2014.

    Comments: 8 pages