-
Fast dynamics of radiofrequency emission in plasmas with runaway electrons
Authors:
P. Buratti,
W. Bin,
A. Cardinali,
D. Carnevale,
C. Castaldo,
O. D'Arcangelo,
F. Napoli,
G. L. Ravera,
A. Selce,
L. Panaccione,
A. Romano,
FTU Team
Abstract:
Radiofrequency emission in the 0.4 - 3 GHz range from FTU plasmas in presence of runaway electrons (RE) has been measured with unprecedentedly high time resolution. Rapid emission bursts associated with enhanced RE pitch angle scattering reveal kinetic instabilities affecting evolution of the RE population from the buildup phase. Such measurements also provide a sensitive monitor for instabilities…
▽ More
Radiofrequency emission in the 0.4 - 3 GHz range from FTU plasmas in presence of runaway electrons (RE) has been measured with unprecedentedly high time resolution. Rapid emission bursts associated with enhanced RE pitch angle scattering reveal kinetic instabilities affecting evolution of the RE population from the buildup phase. Such measurements also provide a sensitive monitor for instabilities during early RE formation. The leading edge of radio bursts is much shorter than interleaving periods of low emission; spectral broadening during growth indicates nonlinear wave coupling as an explanation for the observed intermittency. Radiofrequency emission disappears at the beginning of post-disruption RE plateaus, and subsequently reappears in the shape of very intense bursts accompanied by strong rises of suprathermal electron cyclotron emission.
△ Less
Submitted 20 December, 2020;
originally announced December 2020.
-
Planck Intermediate Results. IX. Detection of the Galactic haze with Planck
Authors:
Planck Collaboration,
P. A. R. Ade,
N. Aghanim,
M. Arnaud,
M. Ashdown,
F. Atrio-Barandela,
J. Aumont,
C. Baccigalupi,
A. Balbi,
A. J. Banday,
R. B. Barreiro,
J. G. Bartlett,
E. Battaner,
K. Benabed,
A. Benoît,
J. -P. Bernard,
M. Bersanelli,
A. Bonaldi,
J. R. Bond,
J. Borrill,
F. R. Bouchet,
C. Burigana,
P. Cabella,
J. -F. Cardoso,
A. Catalano
, et al. (159 additional authors not shown)
Abstract:
Using precise full-sky observations from Planck, and applying several methods of component separation, we identify and characterize the emission from the Galactic "haze" at microwave wavelengths. The haze is a distinct component of diffuse Galactic emission, roughly centered on the Galactic centre, and extends to |b| ~35 deg in Galactic latitude and |l| ~15 deg in longitude. By combining the Planc…
▽ More
Using precise full-sky observations from Planck, and applying several methods of component separation, we identify and characterize the emission from the Galactic "haze" at microwave wavelengths. The haze is a distinct component of diffuse Galactic emission, roughly centered on the Galactic centre, and extends to |b| ~35 deg in Galactic latitude and |l| ~15 deg in longitude. By combining the Planck data with observations from the WMAP we are able to determine the spectrum of this emission to high accuracy, unhindered by the large systematic biases present in previous analyses. The derived spectrum is consistent with power-law emission with a spectral index of -2.55 +/- 0.05, thus excluding free-free emission as the source and instead favouring hard-spectrum synchrotron radiation from an electron population with a spectrum (number density per energy) dN/dE ~ E^-2.1. At Galactic latitudes |b|<30 deg, the microwave haze morphology is consistent with that of the Fermi gamma-ray "haze" or "bubbles," indicating that we have a multi-wavelength view of a distinct component of our Galaxy. Given both the very hard spectrum and the extended nature of the emission, it is highly unlikely that the haze electrons result from supernova shocks in the Galactic disk. Instead, a new mechanism for cosmic-ray acceleration in the centre of our Galaxy is implied.
△ Less
Submitted 27 August, 2012;
originally announced August 2012.
-
W-band prototype of platelet feed-horn array for CMB polarisation measurements
Authors:
Francesco Del Torto,
Marco Bersanelli,
Francesco Cavaliere,
Adriano De Rosa,
Ocleto D'Arcangelo,
Cristian Franceschet,
Massimo Gervasi,
Aniello Mennella,
Enrico Pagana,
Alessandro Simonetto,
Andrea Tartari,
Fabrizio Villa,
Mario Zannoni
Abstract:
We present the design and performance of a 2x2 prototype array of corrugated feed-horns in W-band. The module is fabricated using a so-called "platelet" technique by milling Aluminum plates. This technique is suitable for low-cost and scalable high performance applications. Room temperature Return Loss measurements show a low (<-30 dB) reflection over a 30% bandwidth with a maximum matching of -42…
▽ More
We present the design and performance of a 2x2 prototype array of corrugated feed-horns in W-band. The module is fabricated using a so-called "platelet" technique by milling Aluminum plates. This technique is suitable for low-cost and scalable high performance applications. Room temperature Return Loss measurements show a low (<-30 dB) reflection over a 30% bandwidth with a maximum matching of -42 dB at 100 GHz for all four antennas. Beam pattern measurements indicate good repeatability and a low (-25 dB) sidelobe and crosspolarisation levels. This work is particularly relevant for future Cosmic Microwave Background polarisation measurements, which require large microwave cryogenic detector arrays coupled to high performance corrugated feed horns.
△ Less
Submitted 6 July, 2011;
originally announced July 2011.
-
Planck Early Results XXVI: Detection with Planck and confirmation by XMM-Newton of PLCK G266.6-27.3, an exceptionally X-ray luminous and massive galaxy cluster at z~1
Authors:
Planck Collaboration,
N. Aghanim,
M. Arnaud,
M. Ashdown,
F. Atrio-Barandela,
J. Aumont,
C. Baccigalupi,
A. Balbi,
A. J. Banday,
R. B. Barreiro,
J. G. Bartlett,
E. Battaner,
K. Benabed,
A. Benoît,
J. -P. Bernard,
M. Bersanelli,
R. Bhatia,
H. Böhringer,
A. Bonaldi,
J. R. Bond,
S. Borgani,
J. Borrill,
F. R. Bouchet,
M. L. Brown,
C. Burigana
, et al. (167 additional authors not shown)
Abstract:
We present first results on PLCK G266.6-27.3, a galaxy cluster candidate detected at a signal-to-noise ratio of 5 in the Planck All Sky survey. An XMM-Newton validation observation has allowed us to confirm that the candidate is a bona fide galaxy cluster. With these X-ray data we measure an accurate redshift, z = 0.94 +/- 0.02, and estimate the cluster mass to be M_500 = (7.8 +/- 0.8)e+14 solar m…
▽ More
We present first results on PLCK G266.6-27.3, a galaxy cluster candidate detected at a signal-to-noise ratio of 5 in the Planck All Sky survey. An XMM-Newton validation observation has allowed us to confirm that the candidate is a bona fide galaxy cluster. With these X-ray data we measure an accurate redshift, z = 0.94 +/- 0.02, and estimate the cluster mass to be M_500 = (7.8 +/- 0.8)e+14 solar masses. PLCK G266.6-27.3 is an exceptional system: its luminosity of L_X(0.5-2.0 keV)=(1.4 +/- 0.05)e+45 erg/s, equals that of the two most luminous known clusters in the z > 0.5 universe, and it is one of the most massive clusters at z~1. Moreover, unlike the majority of high-redshift clusters, PLCK G266.6-27.3 appears to be highly relaxed. This observation confirms Planck's capability of detecting high-redshift, high-mass clusters, and opens the way to the systematic study of population evolution in the exponential tail of the mass function.
△ Less
Submitted 27 July, 2011; v1 submitted 7 June, 2011;
originally announced June 2011.
-
Planck early results. III. First assessment of the Low Frequency Instrument in-flight performance
Authors:
A. Mennella,
M. Bersanelli,
R. C. Butler,
A. Curto,
F. Cuttaia,
R. J. Davis,
J. Dick,
M. Frailis,
S. Galeotta,
A. Gregorio,
H. Kurki-Suonio,
C. R. Lawrence,
S. Leach,
J. P. Leahy,
S. Lowe,
D. Maino,
N. Mandolesi,
M. Maris,
E. Martínez-González,
P. R. Meinhold,
G. Morgante,
D. Pearson,
F. Perrotta,
G. Polenta,
T. Poutanen
, et al. (136 additional authors not shown)
Abstract:
The scientific performance of the Planck Low Frequency Instrument (LFI) after one year of in-orbit operation is presented. We describe the main optical parameters and discuss photometric calibration, white noise sensitivity, and noise properties. A preliminary evaluation of the impact of the main systematic effects is presented. For each of the performance parameters, we outline the methods used t…
▽ More
The scientific performance of the Planck Low Frequency Instrument (LFI) after one year of in-orbit operation is presented. We describe the main optical parameters and discuss photometric calibration, white noise sensitivity, and noise properties. A preliminary evaluation of the impact of the main systematic effects is presented. For each of the performance parameters, we outline the methods used to obtain them from the flight data and provide a comparison with pre-launch ground assessments, which are essentially confirmed in flight.
△ Less
Submitted 19 December, 2011; v1 submitted 11 January, 2011;
originally announced January 2011.
-
Planck Early Results: The Planck mission
Authors:
Planck Collaboration,
P. A. R. Ade,
N. Aghanim,
M. Arnaud,
M. Ashdown,
J. Aumont,
C. Baccigalupi,
M. Baker,
A. Balbi,
A. J. Banday,
R. B. Barreiro,
J. G. Bartlett,
E. Battaner,
K. Benabed,
K. Bennett,
A. Benoît,
J. -P. Bernard,
M. Bersanelli,
R. Bhatia,
J. J. Bock,
A. Bonaldi,
J. R. Bond,
J. Borrill,
F. R. Bouchet,
T. Bradshaw
, et al. (250 additional authors not shown)
Abstract:
The European Space Agency's Planck satellite was launched on 14 May 2009, and has been surveying the sky stably and continuously since 13 August 2009. Its performance is well in line with expectations, and it will continue to gather scientific data until the end of its cryogenic lifetime. We give an overview of the history of Planck in its first year of operations, and describe some of the key per…
▽ More
The European Space Agency's Planck satellite was launched on 14 May 2009, and has been surveying the sky stably and continuously since 13 August 2009. Its performance is well in line with expectations, and it will continue to gather scientific data until the end of its cryogenic lifetime. We give an overview of the history of Planck in its first year of operations, and describe some of the key performance aspects of the satellite. This paper is part of a package submitted in conjunction with Planck's Early Release Compact Source Catalogue, the first data product based on Planck to be released publicly. The package describes the scientific performance of the Planck payload, and presents results on a variety of astrophysical topics related to the sources included in the Catalogue, as well as selected topics on diffuse emission.
△ Less
Submitted 16 June, 2011; v1 submitted 11 January, 2011;
originally announced January 2011.
-
Modeling the frequency response of microwave radiometers with QUCS
Authors:
Andrea Zonca,
Bastien Roucaries,
Brian Williams,
Ishai Rubin,
Ocleto D'Arcangelo,
Peter Meinhold,
Philip Lubin,
Cristian Franceschet,
Stefan Jahn,
Aniello Mennella,
Marco Bersanelli
Abstract:
Characterization of the frequency response of coherent radiometric receivers is a key element in estimating the flux of astrophysical emissions, since the measured signal depends on the convolution of the source spectral emission with the instrument band shape.
Laboratory Radio Frequency (RF) measurements of the instrument bandpass often require complex test setups and are subject to a number of…
▽ More
Characterization of the frequency response of coherent radiometric receivers is a key element in estimating the flux of astrophysical emissions, since the measured signal depends on the convolution of the source spectral emission with the instrument band shape.
Laboratory Radio Frequency (RF) measurements of the instrument bandpass often require complex test setups and are subject to a number of systematic effects driven by thermal issues and impedance matching, particularly if cryogenic operation is involved.
In this paper we present an approach to modeling radiometers bandpasses by integrating simulations and RF measurements of individual components. This method is based on QUCS (Quasi Universal Circuit Simulator), an open-source circuit simulator, which gives the flexibility of choosing among the available devices, implementing new analytical software models or using measured S-parameters. Therefore an independent estimate of the instrument bandpass is achieved using standard individual component measurements and validated analytical simulations.
In order to automate the process of preparing input data, running simulations and exporting results we developed the Python package python-qucs and released it under GNU Public License.
We discuss, as working cases, bandpass response modeling of the COFE and Planck Low Frequency Instrument (LFI) radiometers and compare results obtained with QUCS and with a commercial circuit simulator software. The main purpose of bandpass modeling in COFE is to optimize component matching, while in LFI they represent the best estimation of frequency response, since end-to-end measurements were strongly affected by systematic effects.
△ Less
Submitted 20 December, 2010; v1 submitted 29 November, 2010;
originally announced November 2010.
-
Planck pre-launch status: calibration of the Low Frequency Instrument flight model radiometers
Authors:
F. Villa,
L. Terenzi,
M. Sandri,
P. Meinhold,
T. Poutanen,
P. Battaglia,
C. Franceschet,
N. Hughes,
M. Laaninen,
P. Lapolla,
M. Bersanelli,
R. C. Butler,
F. Cuttaia,
O. D'Arcangelo,
M. Frailis,
E. Franceschi,
S. Galeotta,
A. Gregorio,
R. Leonardi,
S. R. Lowe,
N. Mandolesi,
M. Maris,
L. Mendes,
A. Mennella,
G. Morgante
, et al. (49 additional authors not shown)
Abstract:
The Low Frequency Instrument (LFI) on-board the ESA Planck satellite carries eleven radiometer subsystems, called Radiometer Chain Assemblies (RCAs), each composed of a pair of pseudo-correlation receivers. We describe the on-ground calibration campaign performed to qualify the flight model RCAs and to measure their pre-launch performances. Each RCA was calibrated in a dedicated flight-like cryoge…
▽ More
The Low Frequency Instrument (LFI) on-board the ESA Planck satellite carries eleven radiometer subsystems, called Radiometer Chain Assemblies (RCAs), each composed of a pair of pseudo-correlation receivers. We describe the on-ground calibration campaign performed to qualify the flight model RCAs and to measure their pre-launch performances. Each RCA was calibrated in a dedicated flight-like cryogenic environment with the radiometer front-end cooled to 20K and the back-end at 300K, and with an external input load cooled to 4K. A matched load simulating a blackbody at different temperatures was placed in front of the sky horn to derive basic radiometer properties such as noise temperature, gain, and noise performance, e.g. 1/f noise. The spectral response of each detector was measured as was their susceptibility to thermal variation. All eleven LFI RCAs were calibrated. Instrumental parameters measured in these tests, such as noise temperature, bandwidth, radiometer isolation, and linearity, provide essential inputs to the Planck-LFI data analysis.
△ Less
Submitted 14 May, 2010;
originally announced May 2010.
-
A systematic approach to the Planck LFI end-to-end test and its application to the DPC Level 1 pipeline
Authors:
M. Frailis,
M. Maris,
A. Zacchei,
N. Morisset,
R. Rohlfs,
M. Meharga,
P. Binko,
M. Turler,
S. Galeotta,
F. Gasparo,
E. Franceschi,
R. C. Butler,
O. D'Arcangelo,
S. Fogliani,
A. Gregorio,
S. R. Lowe,
G. Maggio,
M. Malaspina,
N. Mandolesi,
P. Manzato,
F. Pasian,
F. Perrotta,
M. Sandri,
L. Terenzi,
M. Tomasi
, et al. (1 additional authors not shown)
Abstract:
The Level 1 of the Planck LFI Data Processing Centre (DPC) is devoted to the handling of the scientific and housekee** telemetry. It is a critical component of the Planck ground segment which has to strictly commit to the project schedule to be ready for the launch and flight operations. In order to guarantee the quality necessary to achieve the objectives of the Planck mission, the design and…
▽ More
The Level 1 of the Planck LFI Data Processing Centre (DPC) is devoted to the handling of the scientific and housekee** telemetry. It is a critical component of the Planck ground segment which has to strictly commit to the project schedule to be ready for the launch and flight operations. In order to guarantee the quality necessary to achieve the objectives of the Planck mission, the design and development of the Level 1 software has followed the ESA Software Engineering Standards. A fundamental step in the software life cycle is the Verification and Validation of the software. The purpose of this work is to show an example of procedures, test development and analysis successfully applied to a key software project of an ESA mission. We present the end-to-end validation tests performed on the Level 1 of the LFI-DPC, by detailing the methods used and the results obtained. Different approaches have been used to test the scientific and housekee** data processing. Scientific data processing has been tested by injecting signals with known properties directly into the acquisition electronics, in order to generate a test dataset of real telemetry data and reproduce as much as possible nominal conditions. For the HK telemetry processing, validation software have been developed to inject known parameter values into a set of real housekee** packets and perform a comparison with the corresponding timelines generated by the Level 1. With the proposed validation and verification procedure, where the on-board and ground processing are viewed as a single pipeline, we demonstrated that the scientific and housekee** processing of the Planck-LFI raw data is correct and meets the project requirements.
△ Less
Submitted 26 January, 2010;
originally announced January 2010.
-
LFI Radiometric Chain Assembly (RCA) data handling "Rachel"
Authors:
M. Malaspina,
E. Franceschi,
P. Battaglia,
P. Binko,
R. C. Butler,
O. D'Arcangelo,
S. Fogliani,
M. Frailis,
C. Franceschet,
S. Galeotta,
F. Gasparo,
A. Gregorio,
M. Lapolla,
R. Leonardi,
G. Maggio,
N. Mandolesi,
P. Manzato,
M. Maris,
M. Meharga,
P. Meinhold,
N. Morisset,
F. Pasian,
F. Perrotta,
R. Rohlfs,
M. Sandri
, et al. (4 additional authors not shown)
Abstract:
This paper is part of the Prelaunch status LFI papers published on JINST (http://www.iop.org/EJ/journal/-page=extra.proc5/1748-0221).
Planck's Low Frequency Instrument is an array of 22 pseudo-correlation radiometers at 30, 44, and 70 GHz. Before integrating the overall array assembly, a first set of tests has been performed for each radiometer chain assembly (RCA), consisting of two radiomete…
▽ More
This paper is part of the Prelaunch status LFI papers published on JINST (http://www.iop.org/EJ/journal/-page=extra.proc5/1748-0221).
Planck's Low Frequency Instrument is an array of 22 pseudo-correlation radiometers at 30, 44, and 70 GHz. Before integrating the overall array assembly, a first set of tests has been performed for each radiometer chain assembly (RCA), consisting of two radiometers. In this paper, we describe Rachel, a software application which has been purposely developed and used during the RCA test campaign to carry out both near-realtime on-line data analysis and data storage (in FITS format) of the raw output from the radiometric chains.
△ Less
Submitted 26 January, 2010;
originally announced January 2010.
-
Planck-LFI: Design and Performance of the 4 Kelvin Reference Load Unit
Authors:
Luca Valenziano,
Francesco Cuttaia,
Adriano De Rosa,
Luca Terenzi,
Alberto Brighenti,
GianPaolo Cazzola,
Anna Garbesi,
Sergio Mariotti,
Giordano Orsi,
Luca Pagan,
Francesco Cavaliere,
Roberto Lapini,
Matteo Biggi,
Enzo Panagin,
Battaglia Paola,
Chris Butler,
Marco Bersanelli,
Ocleto D'Arcangelo,
Steve Levin,
Nazzareno Mandolesi,
Aniello Mennella,
Gianluca Morgante,
Gabriele Morigi,
Maura Sandri,
Alessandro Simonetto
, et al. (13 additional authors not shown)
Abstract:
The LFI radiometers use a pseudo-correlation design where the signal from the sky is continuously compared with a stable reference signal, provided by a cryogenic reference load system. The reference unit is composed by small pyramidal horns, one for each radiometer, 22 in total, facing small absorbing targets, made of a commercial resin ECCOSORB CR (TM), cooled to approximately 4.5 K. Horns and…
▽ More
The LFI radiometers use a pseudo-correlation design where the signal from the sky is continuously compared with a stable reference signal, provided by a cryogenic reference load system. The reference unit is composed by small pyramidal horns, one for each radiometer, 22 in total, facing small absorbing targets, made of a commercial resin ECCOSORB CR (TM), cooled to approximately 4.5 K. Horns and targets are separated by a small gap to allow thermal decoupling. Target and horn design is optimized for each of the LFI bands, centered at 70, 44 and 30 GHz. Pyramidal horns are either machined inside the radiometer 20K module or connected via external electro-formed bended waveguides. The requirement of high stability of the reference signal imposed a careful design for the radiometric and thermal properties of the loads. Materials used for the manufacturing have been characterized for thermal, RF and mechanical properties. We describe in this paper the design and the performance of the reference system.
△ Less
Submitted 26 January, 2010;
originally announced January 2010.
-
Design, development and verification of the 30 and 44 GHz front-end modules for the Planck Low Frequency Instrument
Authors:
R. J. Davis,
A. Wilkinson,
R. D. Davies,
W. F. Winder,
N. Roddis,
E. J. Blackhurst,
D. Lawson,
S. R. Lowe,
C. Baines,
M. Butlin,
A. Galtress,
D. Shepherd,
B. Aja,
E. Artal,
M. Bersanelli,
R. C. Butler,
C. Castelli,
F. Cuttaia,
O. D'Arcangelo,
T. Gaier,
R. Hoyland,
D. Kettle,
R. Leonardi,
N. Mandolesi,
A. Mennella
, et al. (6 additional authors not shown)
Abstract:
We give a description of the design, construction and testing of the 30 and 44 GHz Front End Modules (FEMs) for the Low Frequency Instrument (LFI) of the Planck mission to be launched in 2009. The scientific requirements of the mission determine the performance parameters to be met by the FEMs, including their linear polarization characteristics.
The FEM design is that of a differential pseudo…
▽ More
We give a description of the design, construction and testing of the 30 and 44 GHz Front End Modules (FEMs) for the Low Frequency Instrument (LFI) of the Planck mission to be launched in 2009. The scientific requirements of the mission determine the performance parameters to be met by the FEMs, including their linear polarization characteristics.
The FEM design is that of a differential pseudo-correlation radiometer in which the signal from the sky is compared with a 4-K blackbody load. The Low Noise Amplifier (LNA) at the heart of the FEM is based on indium phosphide High Electron Mobility Transistors (HEMTs). The radiometer incorporates a novel phase-switch design which gives excellent amplitude and phase match across the band.
The noise temperature requirements are met within the measurement errors at the two frequencies. For the most sensitive LNAs, the noise temperature at the band centre is 3 and 5 times the quantum limit at 30 and 44 GHz respectively. For some of the FEMs, the noise temperature is still falling as the ambient temperature is reduced to 20 K. Stability tests of the FEMs, including a measurement of the 1/f knee frequency, also meet mission requirements.
The 30 and 44 GHz FEMs have met or bettered the mission requirements in all critical aspects. The most sensitive LNAs have reached new limits of noise temperature for HEMTs at their band centres. The FEMs have well-defined linear polarization characteristcs.
△ Less
Submitted 26 January, 2010;
originally announced January 2010.
-
Optimization of Planck/LFI on--board data handling
Authors:
M. Maris,
M. Tomasi,
S. Galeotta,
M. Miccolis,
S. Hildebrandt,
M. Frailis,
R. Rohlfs,
N. Morisset,
A. Zacchei,
M. Bersanelli,
P. Binko,
C. Burigana,
R. C. Butler,
F. Cuttaia,
H. Chulani,
O. D'Arcangelo,
S. Fogliani,
E. Franceschi,
F. Gasparo,
F. Gomez,
A. Gregorio,
J. M. Herreros,
R. Leonardi,
P. Leutenegger,
G. Maggio
, et al. (12 additional authors not shown)
Abstract:
To asses stability against 1/f noise, the Low Frequency Instrument (LFI) onboard the Planck mission will acquire data at a rate much higher than the data rate allowed by its telemetry bandwith of 35.5 kbps. The data are processed by an onboard pipeline, followed onground by a reversing step. This paper illustrates the LFI scientific onboard processing to fit the allowed datarate. This is a lossy…
▽ More
To asses stability against 1/f noise, the Low Frequency Instrument (LFI) onboard the Planck mission will acquire data at a rate much higher than the data rate allowed by its telemetry bandwith of 35.5 kbps. The data are processed by an onboard pipeline, followed onground by a reversing step. This paper illustrates the LFI scientific onboard processing to fit the allowed datarate. This is a lossy process tuned by using a set of 5 parameters Naver, r1, r2, q, O for each of the 44 LFI detectors. The paper quantifies the level of distortion introduced by the onboard processing, EpsilonQ, as a function of these parameters. It describes the method of optimizing the onboard processing chain. The tuning procedure is based on a optimization algorithm applied to unprocessed and uncompressed raw data provided either by simulations, prelaunch tests or data taken from LFI operating in diagnostic mode. All the needed optimization steps are performed by an automated tool, OCA2, which ends with optimized parameters and produces a set of statistical indicators, among them the compression rate Cr and EpsilonQ. For Planck/LFI the requirements are Cr = 2.4 and EpsilonQ <= 10% of the rms of the instrumental white noise. To speedup the process an analytical model is developed that is able to extract most of the relevant information on EpsilonQ and Cr as a function of the signal statistics and the processing parameters. This model will be of interest for the instrument data analysis. The method was applied during ground tests when the instrument was operating in conditions representative of flight. Optimized parameters were obtained and the performance has been verified, the required data rate of 35.5 Kbps has been achieved while kee** EpsilonQ at a level of 3.8% of white noise rms well within the requirements.
△ Less
Submitted 26 January, 2010;
originally announced January 2010.
-
Level 1 on-ground telemetry handling in Planck LFI
Authors:
A. Zacchei,
M. Frailis,
M. Maris,
N. Morisset,
R. Rohlfs,
M. Meharga,
P. Binko,
M. Turler,
S. Galeotta,
F. Gasparo,
E. Franceschi,
R. C. Butler,
F. Cuttaia,
O. D'Arcangelo,
S. Fogliani,
A. Gregorio,
R. Leonardi,
S. R. Lowe,
D. Maino,
G. Maggio,
M. Malaspina,
N. Mandolesi,
P. Manzato,
P. Meinhold,
L. Mendes
, et al. (9 additional authors not shown)
Abstract:
The Planck Low Frequency Instrument (LFI) will observe the Cosmic Microwave Background (CMB) by covering the frequency range 30-70 GHz in three bands. The primary instrument data source are the temperature samples acquired by the 22 radiometers mounted on the Planck focal plane. Such samples represent the scientific data of LFI. In addition, the LFI instrument generates the so called housekeepin…
▽ More
The Planck Low Frequency Instrument (LFI) will observe the Cosmic Microwave Background (CMB) by covering the frequency range 30-70 GHz in three bands. The primary instrument data source are the temperature samples acquired by the 22 radiometers mounted on the Planck focal plane. Such samples represent the scientific data of LFI. In addition, the LFI instrument generates the so called housekee** data by sampling regularly the on-board sensors and registers. The housekee** data provides information on the overall health status of the instrument and on the scientific data quality. The scientific and housekee** data are collected on-board into telemetry packets compliant with the ESA Packet Telemetry standards. They represent the primary input to the first processing level of the LFI Data Processing Centre. In this work we show the software systems which build the LFI Level 1. A real-time assessment system, based on the ESA SCOS 2000 generic mission control system, has the main purpose of monitoring the housekee** parameters of LFI and detect possible anomalies. A telemetry handler system processes the housekee** and scientific telemetry of LFI, generating timelines for each acquisition chain and each housekee** parameter. Such timelines represent the main input to the subsequent processing levels of the LFI DPC. A telemetry quick-look system allows the real-time visualization of the LFI scientific and housekee** data, by also calculating quick statistical functions and fast Fourier transforms. The LFI Level 1 has been designed to support all the mission phases, from the instrument ground tests and calibration to the flight operations, and developed according to the ESA engineering standards.
△ Less
Submitted 26 January, 2010;
originally announced January 2010.
-
The Planck-LFI flight model composite waveguides
Authors:
O. D'Arcangelo,
L. Figini,
A. Simonetto,
F. Villa,
M. Pecora,
P. Battaglia,
M. Bersanelli,
R. C. Butler,
F. Cuttaia,
S. Garavaglia,
P. Guzzi,
N. Mandolesi,
A. Mennella,
G. Morgante,
L. Pagan,
L. Valenziano
Abstract:
The Low Frequency Instrument on board the PLANCK satellite is designed to give the most accurate map ever of the CMB anisotropy of the whole sky over a broad frequency band spanning 27 to 77 GHz. It is made of an array of 22 pseudo-correlation radiometers, composed of 11 actively cooled (20 K) Front End Modules (FEMs), and 11 Back End Modules (BEMs) at 300K. The connection between the two parts…
▽ More
The Low Frequency Instrument on board the PLANCK satellite is designed to give the most accurate map ever of the CMB anisotropy of the whole sky over a broad frequency band spanning 27 to 77 GHz. It is made of an array of 22 pseudo-correlation radiometers, composed of 11 actively cooled (20 K) Front End Modules (FEMs), and 11 Back End Modules (BEMs) at 300K. The connection between the two parts is made with rectangular Wave Guides. Considerations of different nature (thermal, electromagnetic and mechanical), imposed stringent requirements on the WGs characteristics and drove their design. From the thermal point of view, the WG should guarantee good insulation between the FEM and the BEM sections to avoid overloading the cryocooler. On the other hand it is essential that the signals do not undergo excessive attenuation through the WG. Finally, given the different positions of the FEM modules behind the focal surface and the mechanical constraints given by the surrounding structures, different mechanical designs were necessary. A composite configuration of Stainless Steel and Copper was selected to satisfy all the requirements. Given the complex shape and the considerable length (about 1.5-2 m), manufacturing and testing the WGs was a challenge. This work deals with the development of the LFI WGs, including the choice of the final configuration and of the fabrication process. It also describes the testing procedure adopted to fully characterize these components from the electromagnetic point of view and the space qualification process they underwent. Results obtained during the test campaign are reported and compared with the stringent requirements. The performance of the LFI WGs is in line with requirements, and the WGs were successfully space qualified.
△ Less
Submitted 26 January, 2010;
originally announced January 2010.
-
The PLANCK LFI flight model ortho-mode transducers
Authors:
O. D'Arcangelo,
A. Simonetto,
L. Figini,
E. Pagana,
F. Villa,
M. Pecora,
P. Battaglia,
M. Bersanelli,
R. C. Butler,
S. Garavaglia,
P. Guzzi,
N. Mandolesi,
C. Sozzi
Abstract:
The Low Frequency Instrument (LFI) of the ESA Planck CMB mission is an array of 22 ultra sensitive pseudocorrelation radiometers working at 30, 44, and 70 GHz. LFI has been calibrated and delivered for integration with the satellite to the European Space Agency on November 2006. The aim of Planck is to measure the anisotropy and polarization of the Cosmic Background Radiation with a sensitivity…
▽ More
The Low Frequency Instrument (LFI) of the ESA Planck CMB mission is an array of 22 ultra sensitive pseudocorrelation radiometers working at 30, 44, and 70 GHz. LFI has been calibrated and delivered for integration with the satellite to the European Space Agency on November 2006. The aim of Planck is to measure the anisotropy and polarization of the Cosmic Background Radiation with a sensitivity and angular resolution never reached before over the full sky. LFI is intrinsically sensitive to polarization thanks to the use of Ortho-Mode Transducers (OMT) located between the feedhorns and the pseudo-correlation radiometers. The OMTs are microwave passive components that divide the incoming radiation into two linear orthogonal components. A set of 11 OMTs (2 at 30 GHz, 3 at 44 GHz, and 6 at 70 GHz) were produced and tested. This work describes the design, development and performance of the eleven Flight Model OMTs of LFI. The final design was reached after several years of development. At first, Elegant Bread Board OMTs were produced to investigate the manufacturing technology and design requirements. Then, a set of 3 Qualification Model (QM) OMTs were designed, manufactured and tested in order to freeze the design and the manufacturing technology for the flight units. Finally, the Flight Models were produced and tested. It is shown that all the OMT units have been accepted for flight and the electromagnetic performance is at least marginally compliant with the requirements. Mechanically, the units passed all the thermoelastic qualification tests after a reworking necessary after the QM campaign.
△ Less
Submitted 26 January, 2010;
originally announced January 2010.
-
Advanced modelling of the Planck-LFI radiometers
Authors:
P. Battaglia,
C. Franceschet,
A . Zonca,
M. Bersanelli,
R. C. Butler,
O. D'Arcangelo,
R. J. Davis,
S. Galeotta,
P. Guzzi,
R. Hoyland,
N. Hughes,
P. Jukkala,
D. Kettle,
M. Laaninen,
R. Leonardi,
D. Maino,
N. Mandolesi,
P. Meinhold,
A. Mennella,
P. Platania,
L. Terenzi,
J. Tuovinen,
J. Varis,
F. Villa,
A. Wilkinson
Abstract:
The Low Frequency Instrument (LFI) is a radiometer array covering the 30-70 GHz spectral range on-board the ESA Planck satellite, launched on May 14th, 2009 to observe the cosmic microwave background (CMB) with unprecedented precision. In this paper we describe the development and validation of a software model of the LFI pseudo-correlation receivers which enables to reproduce and predict all th…
▽ More
The Low Frequency Instrument (LFI) is a radiometer array covering the 30-70 GHz spectral range on-board the ESA Planck satellite, launched on May 14th, 2009 to observe the cosmic microwave background (CMB) with unprecedented precision. In this paper we describe the development and validation of a software model of the LFI pseudo-correlation receivers which enables to reproduce and predict all the main system parameters of interest as measured at each of the 44 LFI detectors. These include system total gain, noise temperature, band-pass response, non-linear response. The LFI Advanced RF Model (LARFM) has been constructed by using commercial software tools and data of each radiometer component as measured at single unit level. The LARFM has been successfully used to reproduce the LFI behavior observed during the LFI ground-test campaign. The model is an essential element in the database of LFI data processing center and will be available for any detailed study of radiometer behaviour during the survey.
△ Less
Submitted 26 January, 2010;
originally announced January 2010.
-
Thermal susceptibility of the Planck-LFI receivers
Authors:
L Terenzi,
M J Salmon,
A Colin,
A Mennella,
G Morgante,
M Tomasi,
P Battaglia,
M Lapolla,
M Bersanelli,
R C Butler,
F Cuttaia,
O D'Arcangelo,
R Davis,
C Franceschet,
S Galeotta,
A Gregorio,
N Hughes,
P Jukkala,
D Kettle,
M Laaninen,
P Leutenegger,
R Leonardi,
N Mandolesi,
M Maris,
P Meinhold
, et al. (11 additional authors not shown)
Abstract:
This paper is part of the Prelaunch status LFI papers published on JINST: http://www.iop.org/EJ/journal/-page=extra.proc5/**st .
This paper describes the impact of the Planck Low Frequency Instrument front end physical temperature fluctuations on the output signal. The origin of thermal instabilities in the instrument are discussed, and an analytical model of their propagation and impact on t…
▽ More
This paper is part of the Prelaunch status LFI papers published on JINST: http://www.iop.org/EJ/journal/-page=extra.proc5/**st .
This paper describes the impact of the Planck Low Frequency Instrument front end physical temperature fluctuations on the output signal. The origin of thermal instabilities in the instrument are discussed, and an analytical model of their propagation and impact on the receivers signal is described. The experimental test setup dedicated to evaluate these effects during the instrument ground calibration is reported together with data analysis methods. Finally, main results obtained are discussed and compared to the requirements.
△ Less
Submitted 26 January, 2010;
originally announced January 2010.
-
Planck-LFI radiometers tuning
Authors:
Francesco Cuttaia,
Aniello Mennella,
Luca Stringhetti,
Michele Maris,
Luca Terenzi,
Maurizio Tomasi,
Fabrizio Villa,
Marco Bersanelli,
Christopher Reginald Butler,
Benedetta Cappellini,
Leticia Perez Cuevas,
Ocleto D'Arcangelo,
Richard Davis,
Marco Frailis,
Cristian Franceschet,
Enrico Franceschi,
Anna Gregorio,
Roger Hoyland,
Rodrigo Leonardi,
Stuart Lowe,
Nazzareno Mandolesi,
Peter Meinhold,
Luis Mendes,
Neil Roddis,
Maura Sandri
, et al. (11 additional authors not shown)
Abstract:
"This paper is part of the Prelaunch status LFI papers published on JINST: http://www.iop.org/EJ/journal/-page=extra.proc5/**st"
This paper describes the Planck Low Frequency Instrument tuning activities performed through the ground test campaigns, from Unit to Satellite Levels. Tuning is key to achieve the best possible instrument performance and tuning parameters strongly depend on thermal…
▽ More
"This paper is part of the Prelaunch status LFI papers published on JINST: http://www.iop.org/EJ/journal/-page=extra.proc5/**st"
This paper describes the Planck Low Frequency Instrument tuning activities performed through the ground test campaigns, from Unit to Satellite Levels. Tuning is key to achieve the best possible instrument performance and tuning parameters strongly depend on thermal and electrical conditions. For this reason tuning has been repeated several times during ground tests and it has been repeated in flight before starting nominal operations. The paper discusses the tuning philosophy, the activities and the obtained results, highlighting developments and changes occurred during test campaigns. The paper concludes with an overview of tuning performed during the satellite cryogenic test campaign (Summer 2008) and of the plans for the just started in-flight calibration.
△ Less
Submitted 26 January, 2010;
originally announced January 2010.
-
Off-line radiometric analysis of Planck/LFI data
Authors:
M. Tomasi,
A. Mennella,
S. Galeotta,
S. R. Lowe,
L. Mendes,
R. Leonardi,
F. Villa,
B. Cappellini,
A. Gregorio,
P. Meinhold,
M. Sandri,
F. Cuttaia,
L. Terenzi,
M. Maris,
L. Valenziano,
M. J. Salmon,
M. Bersanelli,
P. Binko,
R. C. Butler,
O. D'Arcangelo,
S. Fogliani,
M. Frailis,
E. Franceschi,
F. Gasparo,
G. Maggio
, et al. (13 additional authors not shown)
Abstract:
The Planck Low Frequency Instrument (LFI) is an array of 22 pseudo-correlation radiometers on-board the Planck satellite to measure temperature and polarization anisotropies in the Cosmic Microwave Background (CMB) in three frequency bands (30, 44 and 70 GHz). To calibrate and verify the performances of the LFI, a software suite named LIFE has been developed. Its aims are to provide a common pla…
▽ More
The Planck Low Frequency Instrument (LFI) is an array of 22 pseudo-correlation radiometers on-board the Planck satellite to measure temperature and polarization anisotropies in the Cosmic Microwave Background (CMB) in three frequency bands (30, 44 and 70 GHz). To calibrate and verify the performances of the LFI, a software suite named LIFE has been developed. Its aims are to provide a common platform to use for analyzing the results of the tests performed on the single components of the instrument (RCAs, Radiometric Chain Assemblies) and on the integrated Radiometric Array Assembly (RAA). Moreover, its analysis tools are designed to be used during the flight as well to produce periodic reports on the status of the instrument. The LIFE suite has been developed using a multi-layered, cross-platform approach. It implements a number of analysis modules written in RSI IDL, each accessing the data through a portable and heavily optimized library of functions written in C and C++. One of the most important features of LIFE is its ability to run the same data analysis codes both using ground test data and real flight data as input. The LIFE software suite has been successfully used during the RCA/RAA tests and the Planck Integrated System Tests. Moreover, the software has also passed the verification for its in-flight use during the System Operations Verification Tests, held in October 2008.
△ Less
Submitted 26 January, 2010;
originally announced January 2010.
-
Planck LFI flight model feed horns
Authors:
F. Villa,
O. D'Arcangelo,
M. Pecora,
L. Figini,
R. Nesti,
A. Simonetto,
C. Sozzi,
M. Sandri,
P. Battaglia,
P. Guzzi,
M. Bersanelli,
R. C. Butler,
N. Mandolesi
Abstract:
this paper is part of the Prelaunch status LFI papers published on JINST: http://www.iop.org/EJ/journal/-page=extra.proc5/**st The Low Frequency Instrument is optically interfaced with the ESA Planck telescope through 11 corrugated feed horns each connected to the Radiometer Chain Assembly (RCA). This paper describes the design, the manufacturing and the testing of the flight model feed horns.…
▽ More
this paper is part of the Prelaunch status LFI papers published on JINST: http://www.iop.org/EJ/journal/-page=extra.proc5/**st The Low Frequency Instrument is optically interfaced with the ESA Planck telescope through 11 corrugated feed horns each connected to the Radiometer Chain Assembly (RCA). This paper describes the design, the manufacturing and the testing of the flight model feed horns. They have been designed to optimize the LFI optical interfaces taking into account the tight mechanical requirements imposed by the Planck focal plane layout. All the eleven units have been successfully tested and integrated with the Ortho Mode transducers.
△ Less
Submitted 26 January, 2010;
originally announced January 2010.
-
The linearity response of the Planck-LFI flight model receivers
Authors:
A. Mennella,
F. Villa,
L. Terenzi,
F. Cuttaia,
P. Battaglia,
M. Bersanelli,
R. C. Butler,
O. D'Arcangelo,
E. Artal,
R. Davis,
M. Frailis,
C. Franceschet,
S. Galeotta,
A. Gregorio,
N. Hughes,
P. Jukkala,
D. Kettle,
V. -H. Kilpiä,
M. Laaninen,
P. M. Lapolla,
R. Leonardi,
P. Leutenegger,
S. Lowe,
N. Mandolesi,
M. Maris
, et al. (15 additional authors not shown)
Abstract:
In this paper we discuss the linearity response of the Planck-LFI receivers, with particular reference to signal compression measured on the 30 and 44 GHz channels. In the article we discuss the various sources of compression and present a model that accurately describes data measured during tests performed with individual radiomeric chains. After discussing test results we present the best para…
▽ More
In this paper we discuss the linearity response of the Planck-LFI receivers, with particular reference to signal compression measured on the 30 and 44 GHz channels. In the article we discuss the various sources of compression and present a model that accurately describes data measured during tests performed with individual radiomeric chains. After discussing test results we present the best parameter set representing the receiver response and discuss the impact of non linearity on in-flight calibration, which is shown to be negligible.
△ Less
Submitted 26 January, 2010;
originally announced January 2010.
-
Noise Properties of the Planck-LFI Receivers
Authors:
P. Meinhold,
R. Leonardi,
B. Aja,
E. Artal,
P. Battaglia,
M. Bersanelli,
E. Blackhurst,
C. R. Butler,
L. P. Cuevas,
F. Cuttaia,
O. D'Arcangelo,
R. Davis,
M. L. de la Fuente,
M. Frailis,
C. Franceschet,
E. Franceschi,
T. Gaier,
S. Galeotta,
A. Gregorio,
R. Hoyland,
N. Hughes,
P. Jukkala,
D. Kettle,
M. Laaninen,
P. Leutenegger
, et al. (25 additional authors not shown)
Abstract:
The Planck Low Frequency Instrument (LFI) radiometers have been tested extensively during several dedicated campaigns. The present paper reports the principal noise properties of the LFI radiometers.
The Planck Low Frequency Instrument (LFI) radiometers have been tested extensively during several dedicated campaigns. The present paper reports the principal noise properties of the LFI radiometers.
△ Less
Submitted 26 January, 2010;
originally announced January 2010.
-
Planck-LFI radiometers' spectral response
Authors:
A Zonca,
C Franceschet,
P Battaglia,
F Villa,
A Mennella,
O D'Arcangelo,
R Silvestri,
M Bersanelli,
E Artal,
R C Butler,
F Cuttaia,
R J Davis,
S Galeotta,
N Hughes,
P Jukkala,
V-H Kilpia,
M Laaninen,
N Mandolesi,
M Maris,
L Mendes,
M Sandri,
L Terenzi,
J Tuovinen,
J Varis,
A Wilkinson
Abstract:
The Low Frequency Instrument (LFI) is an array of pseudo-correlation radiometers on board the Planck satellite, the ESA mission dedicated to precision measurements of the Cosmic Microwave Background. The LFI covers three bands centred at 30, 44 and 70 GHz, with a goal bandwidth of 20% of the central frequency.
The characterization of the broadband frequency response of each radiometer is neces…
▽ More
The Low Frequency Instrument (LFI) is an array of pseudo-correlation radiometers on board the Planck satellite, the ESA mission dedicated to precision measurements of the Cosmic Microwave Background. The LFI covers three bands centred at 30, 44 and 70 GHz, with a goal bandwidth of 20% of the central frequency.
The characterization of the broadband frequency response of each radiometer is necessary to understand and correct for systematic effects, particularly those related to foreground residuals and polarization measurements. In this paper we present the measured band shape of all the LFI channels and discuss the methods adopted for their estimation. The spectral characterization of each radiometer was obtained by combining the measured spectral response of individual units through a dedicated RF model of the LFI receiver scheme.
As a consistency check, we also attempted end-to-end spectral measurements of the integrated radiometer chain in a cryogenic chamber. However, due to systematic effects in the measurement setup, only qualitative results were obtained from these tests. The measured LFI bandpasses exhibit a moderate level of ripple, compatible with the instrument scientific requirements.
△ Less
Submitted 26 January, 2010;
originally announced January 2010.
-
Planck pre-launch status: Low Frequency Instrument calibration and expected scientific performance
Authors:
A. Mennella,
M. Bersanelli,
R. C. Butler,
F. Cuttaia,
O. D'Arcangelo,
R. J. Davis,
M. Frailis,
S. Galeotta,
A. Gregorio,
C. R. Lawrence,
R. Leonardi,
S. R. Lowe,
N. Mandolesi,
M. Maris,
P. Meinhold,
L. Mendes,
G. Morgante,
M. Sandri,
L. Stringhetti,
L. Terenzi,
M. Tomasi,
L. Valenziano,
F. Villa,
A. Zacchei,
A. Zonca
, et al. (61 additional authors not shown)
Abstract:
We give the calibration and scientific performance parameters of the Planck Low Frequency Instrument (LFI) measured during the ground cryogenic test campaign. These parameters characterise the instrument response and constitute our best pre-launch knowledge of the LFI scientific performance. The LFI shows excellent $1/f$ stability and rejection of instrumental systematic effects; measured noise…
▽ More
We give the calibration and scientific performance parameters of the Planck Low Frequency Instrument (LFI) measured during the ground cryogenic test campaign. These parameters characterise the instrument response and constitute our best pre-launch knowledge of the LFI scientific performance. The LFI shows excellent $1/f$ stability and rejection of instrumental systematic effects; measured noise performance shows that LFI is the most sensitive instrument of its kind. The set of measured calibration parameters will be updated during flight operations through the end of the mission.
△ Less
Submitted 25 January, 2010;
originally announced January 2010.
-
Planck pre-launch status: Design and description of the Low Frequency Instrument
Authors:
M. Bersanelli,
N. Mandolesi,
R. C. Butler,
A. Mennella,
F. Villa,
B. Aja,
E. Artal,
E. Artina,
C. Baccigalupi,
M. Balasini,
G. Baldan,
A. Banday,
P. Bastia,
P. Battaglia,
T. Bernardino,
E. Blackhurst,
L. Boschini,
C. Burigana,
G. Cafagna,
B. Cappellini,
F. Cavaliere,
F. Colombo,
G. Crone,
F. Cuttaia,
O. D'Arcangelo
, et al. (87 additional authors not shown)
Abstract:
In this paper we present the Low Frequency Instrument (LFI), designed and developed as part of the Planck space mission, the ESA program dedicated to precision imaging of the cosmic microwave background (CMB). Planck-LFI will observe the full sky in intensity and polarisation in three frequency bands centred at 30, 44 and 70 GHz, while higher frequencies (100-850 GHz) will be covered by the HFI…
▽ More
In this paper we present the Low Frequency Instrument (LFI), designed and developed as part of the Planck space mission, the ESA program dedicated to precision imaging of the cosmic microwave background (CMB). Planck-LFI will observe the full sky in intensity and polarisation in three frequency bands centred at 30, 44 and 70 GHz, while higher frequencies (100-850 GHz) will be covered by the HFI instrument. The LFI is an array of microwave radiometers based on state-of-the-art Indium Phosphide cryogenic HEMT amplifiers implemented in a differential system using blackbody loads as reference signals. The front-end is cooled to 20K for optimal sensitivity and the reference loads are cooled to 4K to minimise low frequency noise. We provide an overview of the LFI, discuss the leading scientific requirements and describe the design solutions adopted for the various hardware subsystems. The main drivers of the radiometric, optical and thermal design are discussed, including the stringent requirements on sensitivity, stability, and rejection of systematic effects. Further details on the key instrument units and the results of ground calibration are provided in a set of companion papers.
△ Less
Submitted 19 January, 2010;
originally announced January 2010.
-
Planck pre-launch status: the Planck-LFI programme
Authors:
N. Mandolesi,
M. Bersanelli,
R. C. Butler,
E. Artal,
C. Baccigalupi,
A. Balbi,
A. J. Banday,
R. B. Barreiro,
M. Bartelmann,
K. Bennett,
P. Bhandari,
A. Bonaldi,
J. Borrill,
M. Bremer,
C. Burigana,
R. C. Bowman,
P. Cabella,
C. Cantalupo,
B. Cappellini,
T. Courvoisier,
G. Crone,
F. Cuttaia,
L. Danese,
O. D'Arcangelo,
R. D. Davies
, et al. (118 additional authors not shown)
Abstract:
This paper provides an overview of the Low Frequency Instrument (LFI) programme within the ESA Planck mission. The LFI instrument has been developed to produce high precision maps of the microwave sky at frequencies in the range 27-77 GHz, below the peak of the cosmic microwave background (CMB) radiation spectrum. The scientific goals are described, ranging from fundamental cosmology to Galactic…
▽ More
This paper provides an overview of the Low Frequency Instrument (LFI) programme within the ESA Planck mission. The LFI instrument has been developed to produce high precision maps of the microwave sky at frequencies in the range 27-77 GHz, below the peak of the cosmic microwave background (CMB) radiation spectrum. The scientific goals are described, ranging from fundamental cosmology to Galactic and extragalactic astrophysics. The instrument design and development are outlined, together with the model philosophy and testing strategy. The instrument is presented in the context of the Planck mission. The LFI approach to ground and inflight calibration is described. We also describe the LFI ground segment. We present the results of a number of tests demonstrating the capability of the LFI data processing centre (DPC) to properly reduce and analyse LFI flight data, from telemetry information to calibrated and cleaned time ordered data, sky maps at each frequency (in temperature and polarization), component emission maps (CMB and diffuse foregrounds), catalogs for various classes of sources (the Early Release Compact Source Catalogue and the Final Compact Source Catalogue). The organization of the LFI consortium is briefly presented as well as the role of the core team in data analysis and scientific exploitation. All tests carried out on the LFI flight model demonstrate the excellent performance of the instrument and its various subunits. The data analysis pipeline has been tested and its main steps verified. In the first three months after launch, the commissioning, calibration, performance, and verification phases will be completed, after which Planck will begin its operational life, in which LFI will have an integral part.
△ Less
Submitted 15 January, 2010;
originally announced January 2010.
-
The White Mountain Polarimeter Telescope and an Upper Limit on CMB Polarization
Authors:
Alan R. Levy,
Rodrigo Leonardi,
Markus Ansmann,
Marco Bersanelli,
Jeffery Childers,
Terrence D. Cole,
Ocleto D'Arcangelo,
G. Vietor Davis,
Philip M. Lubin,
Joshua Marvil,
Peter R. Meinhold,
Gerald Miller,
Hugh O`Neill,
Fabrizio Stavola,
Nathan C. Stebor,
Peter T. Timbie,
Maarten van der Heide,
Fabrizio Villa,
Thyrso Villela,
Brian D. Williams,
Carlos A. Wuensche
Abstract:
The White Mountain Polarimeter (WMPol) is a dedicated ground-based microwave telescope and receiver system for observing polarization of the Cosmic Microwave Background. WMPol is located at an altitude of 3880 meters on a plateau in the White Mountains of Eastern California, USA, at the Barcroft Facility of the University of California White Mountain Research Station. Presented here is a descrip…
▽ More
The White Mountain Polarimeter (WMPol) is a dedicated ground-based microwave telescope and receiver system for observing polarization of the Cosmic Microwave Background. WMPol is located at an altitude of 3880 meters on a plateau in the White Mountains of Eastern California, USA, at the Barcroft Facility of the University of California White Mountain Research Station. Presented here is a description of the instrument and the data collected during April through October 2004. We set an upper limit on $E$-mode polarization of 14 $μ\mathrm{K}$ (95% confidence limit) in the multipole range $170<\ell<240$. This result was obtained with 422 hours of observations of a 3 $\mathrm{deg}^2$ sky area about the North Celestial Pole, using a 42 GHz polarimeter. This upper limit is consistent with $EE$ polarization predicted from a standard $Λ$-CDM concordance model.
△ Less
Submitted 22 April, 2008;
originally announced April 2008.
-
The Low Frequency Instrument in the ESA Planck mission
Authors:
A. Mennella,
M. Bersanelli,
B. Cappellini,
D. Maino,
P. Platania,
S. Garavaglia,
R. C. Butler,
N. Mandolesi F. Pasian,
O. D'arcangelo,
A. Simonetto,
C. Sozzi
Abstract:
Measurements of the cosmic microwave background (CMB) allow high precision observation of the cosmic plasma at redshift z~1100. After the success of the NASA satellite COBE, that in 1992 provided the first detection of the CMB anisotropy, results from many ground-based and balloon-borne experiments have showed a remarkable consistency between different results and provided quantitative estimates…
▽ More
Measurements of the cosmic microwave background (CMB) allow high precision observation of the cosmic plasma at redshift z~1100. After the success of the NASA satellite COBE, that in 1992 provided the first detection of the CMB anisotropy, results from many ground-based and balloon-borne experiments have showed a remarkable consistency between different results and provided quantitative estimates of fundamental cosmological properties. During the current year the team of the NASA WMAP satellite has released the first improved full-sky maps of the CMB since COBE, leading to a deeper insight in the origin and evolution of the Universe. The ESA satellite Planck, scheduled for launch in 2007, is designed to provide the ultimate measurement of the CMB temperature anisotropy over the full sky, with an accuracy that will be limited only by astrophysical foregrounds, and robust detection of polarisation anisotropy. Planck will observe the sky with two instruments over a wide spectral band (the Low Frequency Instrument, based on coherent radiometers, from 30 to 70 GHz and the High Frequency Instrument, based on bolometric detectors, from 100 to 857 GHz). The mission performances will improve dramatically the scientific return compared to WMAP. Furthermore the LFI radiometers (as well as some of the HFI bolometers) are intrinsically sensitive to polarisation so that by combining the data from different receivers it will be possible to measure accurately the E mode and to detect the B mode of the polarisation power spectrum. Planck sensitivity will offer also the possibility to detect the non-Gaussianities imprinted in the CMB.
△ Less
Submitted 2 October, 2003;
originally announced October 2003.
-
High Performances Corrugated Feed Horns for Space Applications at Millimetre Wavelengths
Authors:
F. Villa,
M. Sandri,
N. Mandolesi,
R. Nesti,
M. Bersanelli,
A. Simonetto,
C. Sozzi,
O. D'Arcangelo,
V. Muzzini,
A. Mennella,
P. Guzzi,
P. Radaelli,
R. Fusi,
E. Alippi
Abstract:
We report on the design, fabrication and testing of a set of high performance corrugated feed horns at 30 GHz, 70 GHz and 100 GHz, built as advanced prototypes for the Low Frequency Instrument (LFI) of the ESA Planck mission. The electromagnetic designs include linear (100 GHz) and dual shaped (30 and 70 GHz) profiles. Fabrication has been achieved by direct machining at 30 GHz, and by electro-f…
▽ More
We report on the design, fabrication and testing of a set of high performance corrugated feed horns at 30 GHz, 70 GHz and 100 GHz, built as advanced prototypes for the Low Frequency Instrument (LFI) of the ESA Planck mission. The electromagnetic designs include linear (100 GHz) and dual shaped (30 and 70 GHz) profiles. Fabrication has been achieved by direct machining at 30 GHz, and by electro-formation at higher frequencies. The measured performances on side lobes and return loss meet the stringent Planck requirements over the large (20%) instrument bandwidth. Moreover, the advantage in terms of main lobe shape and side lobes levels of the dual profiled designs has been demonstrated.
△ Less
Submitted 16 July, 2003;
originally announced July 2003.