-
Life Cycle Assessment of the Athena X-ray Integral Field Unit
Authors:
Didier Barret,
Vincent Albouys,
Jürgen Knödlseder,
Xavier Loizillon,
Matteo D'Andrea,
Florence Ardellier,
Simon Bandler,
Pieter Dieleman,
Lionel Duband,
Luc Dubbeldam,
Claudio Macculi,
Eduardo Medinaceli,
Francois Pajot,
Damien Prêle,
Laurent Ravera,
Tanguy Thibert,
Isabel Vera Trallero,
Natalie Webb
Abstract:
The X-ray Integral Field Unit (X-IFU) is the high-resolution X-ray spectrometer to fly on board the Athena Space Observatory of the European Space Agency (ESA). It is being developed by an international Consortium led by France, involving twelve ESA member states, plus the United States. It is a cryogenic instrument, involving state of the art technology, such as micro-calorimeters, to be read out…
▽ More
The X-ray Integral Field Unit (X-IFU) is the high-resolution X-ray spectrometer to fly on board the Athena Space Observatory of the European Space Agency (ESA). It is being developed by an international Consortium led by France, involving twelve ESA member states, plus the United States. It is a cryogenic instrument, involving state of the art technology, such as micro-calorimeters, to be read out by low noise electronics. As the instrument was undergoing its system requirement review (in 2022), a life cycle assessment (LCA) was performed to estimate the environmental impacts associated with the development of the sub-systems that were under the responsibility of the X-IFU Consortium. The assessment included the supply, manufacturing and testing of sub systems, as well as involved logistics and manpower. We find that the most significant environmental impacts arise from testing activities, which is related to energy consumption in clean rooms, office work, which is related to energy consumption in office buildings, and instrument manufacturing, which is related to the use of mineral and metal resources. Furthermore, business travels is another area of concern, despite the policy to reduced flying adopted by the Consortium. As the instrument is now being redesigned to fit within the new boundaries set by ESA, the LCA will be updated, with a focus on the hot spots identified in the first iteration. The new configuration, consolidated in 2023, is significantly different from the previously studied version and is marked by an increase of the perimeter of responsibility for the Consortium. This will need to be folded in the updated LCA, kee** the ambition to reduce the environmental footprint of X-IFU, while complying with its stringent requirements in terms of performance and risk management.
△ Less
Submitted 23 April, 2024;
originally announced April 2024.
-
Clarifying the Radiative Decay of the Hoyle State with Charged-Particle Spectroscopy
Authors:
D. Dell'Aquila,
I. Lombardo,
L. Redigolo,
M. Vigilante,
F. Angelini,
L. Baldesi,
S. Barlini,
A. Best,
A. Camaiani,
G. Casini,
C. Ciampi,
M. Cicerchia,
M. D'Andrea,
J. Diklić,
D. Fabris,
B. Gongora Servin,
A. Gottardo,
F. Gramegna,
G. Imbriani,
T. Marchi,
A. Massara,
D. Mengoni,
A. Ordine,
L. Palada,
G. Pasquali
, et al. (12 additional authors not shown)
Abstract:
Carbon is a fundamental chemical constituent for the existence of life on Earth. It is forged in red giant stars and its formation is determined by the properties of the Hoyle state ($7.654$ MeV, $0^+$), namely by the competition of its very rare \emph{radiative decay} and its dominant particle-decay. However, there is presently a strong tension in the determination of the radiative decay \emph{br…
▽ More
Carbon is a fundamental chemical constituent for the existence of life on Earth. It is forged in red giant stars and its formation is determined by the properties of the Hoyle state ($7.654$ MeV, $0^+$), namely by the competition of its very rare \emph{radiative decay} and its dominant particle-decay. However, there is presently a strong tension in the determination of the radiative decay \emph{branching ratio}, posing major implications on several fundamental aspects of nucleosynthesis and stellar evolution. In this work, we report on an almost background-free measurement of the radiative decay branching ratio of the Hoyle state using charged particle coincidence techniques. We exploit a deuteron on nitrogen-14 nuclear reaction to produce, in a terrestrial laboratory, $^{12}$C nuclei excited in the Hoyle state. The radiative branching ratio is directly deduced by counting their total number and the number of events in which they lead, after radiative emission, to a $^{12}$C in its ground state. The present particle-particle coincidence experiment adopts several techniques to minimize the background and clearly identify the signal associated with the radiative decay. Furthermore, for the first time in a similar experiment, we perform a careful topological study of the coincidence detection efficiency in two dimensions, allowing to reach unitary coincidence efficiency and to have under full control one of the most underhand sources of systematic errors. The new findings contradict recent findings with gamma-particle coincidence techniques and are in excellent agreement with the former estimate of the literature.
△ Less
Submitted 31 January, 2024;
originally announced January 2024.
-
Thermalization of a SQUID chip at cryogenic temperature: Thermal conductance measurement for GE 7031 Varnish Glue, Apiezon N Grease and Rubber Cement between 20 and 200 mK
Authors:
M. D'Andrea,
G. Torrioli,
C. Macculi,
M. Kiviranta
Abstract:
In the context of the ATHENA X-IFU Cryogenic AntiCoincidence Detector (CryoAC) development, we have studied the thermalization properties of a 2mm x 2mm SQUID chip. The chip is glued on a front-end PCB and operated on the cold stage of a dilution refrigerator (TBASE < 20 mK). We performed thermal conductance measurements by using different materials to glue the SQUID chip on the PCB. These have be…
▽ More
In the context of the ATHENA X-IFU Cryogenic AntiCoincidence Detector (CryoAC) development, we have studied the thermalization properties of a 2mm x 2mm SQUID chip. The chip is glued on a front-end PCB and operated on the cold stage of a dilution refrigerator (TBASE < 20 mK). We performed thermal conductance measurements by using different materials to glue the SQUID chip on the PCB. These have been repeated in subsequent cryostat runs, to highlight degradation effects due to thermal cycles. Here, we present the results obtained by glues and greases widely used in cryogenic environments, i.e. GE 7031 Varnish Glue, Apiezon N Grease and Rubber Cement.
△ Less
Submitted 22 January, 2024;
originally announced January 2024.
-
The TES-based Cryogenic AntiCoincidence Detector (CryoAC) of ATHENA X-IFU: a large area silicon microcalorimeter for background particles detection
Authors:
M. D'Andrea,
C. Macculi,
S. Lotti,
L. Piro,
A. Argan,
G. Minervini,
G. Torrioli,
F. Chiarello,
L. Ferrari Barusso,
E. Celasco,
G. Gallucci,
F. Gatti,
D. Grosso,
M. Rigano,
D. Brienza,
E. Cavazzuti,
A. Volpe
Abstract:
We are develo** the Cryogenic AntiCoincidence detector (CryoAC) of the ATHENA X-IFU spectrometer. It is a TES-based particle detector aimed to reduce the background of the instrument. Here, we present the result obtained with the last CryoAC single-pixel prototype. It is based on a 1 cm2 silicon absorber sensed by a single 2mm x 1mm Ir/Au TES, featuring an on-chip heater for calibration and diag…
▽ More
We are develo** the Cryogenic AntiCoincidence detector (CryoAC) of the ATHENA X-IFU spectrometer. It is a TES-based particle detector aimed to reduce the background of the instrument. Here, we present the result obtained with the last CryoAC single-pixel prototype. It is based on a 1 cm2 silicon absorber sensed by a single 2mm x 1mm Ir/Au TES, featuring an on-chip heater for calibration and diagnostic purposes. We have illuminated the sample with 55Fe (6 keV line) and 241Am (60 keV line) radioactive sources, thus studying the detector response and the heater calibration accuracy at low energy. Furthermore, we have operated the sample in combination with a past-generation CryoAC prototype. Here, by analyzing the coincident detections between the two detectors, we have been able to characterize the background spectrum of the laboratory environment and disentangle the primary (i.e. cosmic muons) and secondaries (mostly secondary photons and electrons) signatures in the spectral shape.
△ Less
Submitted 19 January, 2024;
originally announced January 2024.
-
Power deposition studies for standard and crystal-assisted heavy ion collimation inthe CERN Large Hadron Collider
Authors:
J. B. Potoine,
R. Bruce,
R. Cai,
F. Cerutti,
M. D'Andrea,
L. Esposito,
P. D. Hermes,
A. Lechner,
D. Mirarchi,
S. Redaelli,
V. Rodin,
F. Salvat Pujo,
P. Schoofs,
A. Waets,
F. Wrobel
Abstract:
The LHC heavy-ion program with $^{208}$Pb$^{82+}$ beams will benefit from a significant increase of the beam intensity when entering its High-Luminosity era in Run~3 (2023). The stored energy is expected to surpass 20~MJ per beam. The LHC is equipped with a betatron collimation system, which intercepts the transverse beam halo and protects sensitive equipment such as superconducting magnets agains…
▽ More
The LHC heavy-ion program with $^{208}$Pb$^{82+}$ beams will benefit from a significant increase of the beam intensity when entering its High-Luminosity era in Run~3 (2023). The stored energy is expected to surpass 20~MJ per beam. The LHC is equipped with a betatron collimation system, which intercepts the transverse beam halo and protects sensitive equipment such as superconducting magnets against beam losses. However, nuclear fragmentation and electromagnetic dissociation of $^{208}$Pb$^{82+}$ ions in collimators generates a flux of secondary fragments, which are lost in downstream dispersion suppressor and arc cells. These secondary ions may pose a performance limitation in upcoming runs since they can induce magnet quenches. In order to mitigate this risk, an alternative collimation technique, relying on bent crystals as primary collimators, will be used in forthcoming heavy-ion runs. In this paper, we study the power deposition in superconducting magnets by means of tracking and \textsc{FLUKA} shower simulations, comparing the standard collimation system against the crystal-based one. In order to quantify the predictive ability of the simulation model, we present absolute benchmarks against beam loss monitor measurements from the 2018 $^{208}$Pb$^{82+}$ run at 6.37~$Z$TeV. The benchmarks cover several hundred meters of beamline, from the primary collimators to the first arc cells. Based on these studies, we provide a detailed analysis of ion fragmentation and leakage to the cold magnets and quantify the expected quench margin in future $^{208}$Pb$^{82+}$ runs.
△ Less
Submitted 7 April, 2023;
originally announced April 2023.
-
The Athena X-ray Integral Field Unit: a consolidated design for the system requirement review of the preliminary definition phase
Authors:
Didier Barret,
Vincent Albouys,
Jan-Willem den Herder,
Luigi Piro,
Massimo Cappi,
Juhani Huovelin,
Richard Kelley,
J. Miguel Mas-Hesse,
Stéphane Paltani,
Gregor Rauw,
Agata Rozanska,
Jiri Svoboda,
Joern Wilms,
Noriko Yamasaki,
Marc Audard,
Simon Bandler,
Marco Barbera,
Xavier Barcons,
Enrico Bozzo,
Maria Teresa Ceballos,
Ivan Charles,
Elisa Costantini,
Thomas Dauser,
Anne Decourchelle,
Lionel Duband
, et al. (274 additional authors not shown)
Abstract:
The Athena X-ray Integral Unit (X-IFU) is the high resolution X-ray spectrometer, studied since 2015 for flying in the mid-30s on the Athena space X-ray Observatory, a versatile observatory designed to address the Hot and Energetic Universe science theme, selected in November 2013 by the Survey Science Committee. Based on a large format array of Transition Edge Sensors (TES), it aims to provide sp…
▽ More
The Athena X-ray Integral Unit (X-IFU) is the high resolution X-ray spectrometer, studied since 2015 for flying in the mid-30s on the Athena space X-ray Observatory, a versatile observatory designed to address the Hot and Energetic Universe science theme, selected in November 2013 by the Survey Science Committee. Based on a large format array of Transition Edge Sensors (TES), it aims to provide spatially resolved X-ray spectroscopy, with a spectral resolution of 2.5 eV (up to 7 keV) over an hexagonal field of view of 5 arc minutes (equivalent diameter). The X-IFU entered its System Requirement Review (SRR) in June 2022, at about the same time when ESA called for an overall X-IFU redesign (including the X-IFU cryostat and the cooling chain), due to an unanticipated cost overrun of Athena. In this paper, after illustrating the breakthrough capabilities of the X-IFU, we describe the instrument as presented at its SRR, browsing through all the subsystems and associated requirements. We then show the instrument budgets, with a particular emphasis on the anticipated budgets of some of its key performance parameters. Finally we briefly discuss on the ongoing key technology demonstration activities, the calibration and the activities foreseen in the X-IFU Instrument Science Center, and touch on communication and outreach activities, the consortium organisation, and finally on the life cycle assessment of X-IFU aiming at minimising the environmental footprint, associated with the development of the instrument. Thanks to the studies conducted so far on X-IFU, it is expected that along the design-to-cost exercise requested by ESA, the X-IFU will maintain flagship capabilities in spatially resolved high resolution X-ray spectroscopy, enabling most of the original X-IFU related scientific objectives of the Athena mission to be retained. (abridged).
△ Less
Submitted 28 November, 2022; v1 submitted 30 August, 2022;
originally announced August 2022.
-
ATHENA X-IFU Demonstration Model: First joint operation of the main TES Array and its Cryogenic AntiCoincidence Detector (CryoAC)
Authors:
M. D'Andrea,
K. Ravensberg,
A. Argan,
D. Brienza,
S. Lotti,
C. Macculi,
G. Minervini,
L. Piro,
G. Torrioli,
F. Chiarello,
L. Ferrari Barusso,
M. Biasotti,
G. Gallucci,
F. Gatti,
M. Rigano,
H. Akamatsu,
J. Dercksen,
L. Gottardi,
F. de Groote,
R. den Hartog,
J. -W. den Herder,
R. Hoogeveen,
B. Jackson,
A. McCalden,
S. Rosman
, et al. (6 additional authors not shown)
Abstract:
The X-IFU is the cryogenic spectrometer onboard the future ATHENA X-ray observatory. It is based on a large array of TES microcalorimeters, which works in combination with a Cryogenic AntiCoincidence detector (CryoAC). This is necessary to reduce the particle background level thus enabling part of the mission science goals. Here we present the first joint test of X-IFU TES array and CryoAC Demonst…
▽ More
The X-IFU is the cryogenic spectrometer onboard the future ATHENA X-ray observatory. It is based on a large array of TES microcalorimeters, which works in combination with a Cryogenic AntiCoincidence detector (CryoAC). This is necessary to reduce the particle background level thus enabling part of the mission science goals. Here we present the first joint test of X-IFU TES array and CryoAC Demonstration Models, performed in a FDM setup. We show that it is possible to operate properly both detectors, and we provide a preliminary demonstration of the anti-coincidence capability of the system achieved by the simultaneous detection of cosmic muons.
△ Less
Submitted 30 June, 2022;
originally announced June 2022.
-
Demonstration of MHz frequency domain multiplexing readout of 37 transition edge sensors for high-resolution x-ray imaging spectrometers
Authors:
H. Akamatsu,
D. Vaccaro,
L. Gottardi,
J. van der Kuur,
C. P. de Vries,
M. Kiviranta,
K. Ravensberg,
M. D'Andrea,
E. Taralli,
M. de Wit,
M. P. Bruijn,
P. van der Hulst,
R. H. den Hartog,
B-J. van Leeuwen,
A. J. van der Linden,
A. J McCalden,
K. Nagayoshi,
A. C. T. Nieuwenhuizen,
M. L. Ridder,
S. Visser,
P. van Winden,
J. R. Gao,
R. W. M. Hoogeveen,
B. D. Jackson,
J-W. A. den Herder
Abstract:
We report on the development and demonstration of a MHz frequency domain multiplexing (FDM) technology to read out arrays of cryogenic transition edge sensor (TES) X-ray microcalorimeters. In our FDM scheme, TESs are AC-biased at different resonant frequencies in the low MHz range through an array of high-$Q$ LC resonators. The current signals of all TESs are summed at superconducting quantum inte…
▽ More
We report on the development and demonstration of a MHz frequency domain multiplexing (FDM) technology to read out arrays of cryogenic transition edge sensor (TES) X-ray microcalorimeters. In our FDM scheme, TESs are AC-biased at different resonant frequencies in the low MHz range through an array of high-$Q$ LC resonators. The current signals of all TESs are summed at superconducting quantum interference devices (SQUIDs). We have demonstrated multiplexing for a readout of 31 pixels using room temperature electronics, high-$Q$ LC filters and TES arrays developed at SRON, and SQUID arrays from VTT. We repeated this on a second setup with 37 pixels. The summed X-ray spectral resolutions $@$ 5.9 keV are $ΔE_{\rm 31 pix ~MUX}=2.14\pm0.03$ eV and $ΔE_{\rm 37 pix ~MUX}=2.23\pm0.03$ eV. The demonstrated results are comparable with other multiplexing approaches. There is potential to further improve the spectral resolution and to increase the number of multiplexed TESs, and to open up applications for TES X-ray microcalorimeters.
△ Less
Submitted 2 November, 2021;
originally announced November 2021.
-
High Aspect Ratio Transition Edge Sensors for X-ray Spectrometry
Authors:
M. de Wit,
L. Gottardi,
E. Taralli,
K. Nagayoshi,
M. L. Ridder,
H. Akamatsu,
M. P. Bruijn,
M. D'Andrea,
J. van der Kuur,
K. Ravensberg,
D. Vaccaro,
S. Visser,
J. R. Gao,
J. -W. A. den Herder
Abstract:
We are develo** large TES arrays in combination with FDM readout for the next generation of X-ray space observatories. For operation under AC-bias, the TESs have to be carefully designed and optimized. In particular, the use of high aspect ratio devices will help to mitigate non-ideal behaviour due to the weak-link effect. In this paper, we present a full characterization of a TES array containi…
▽ More
We are develo** large TES arrays in combination with FDM readout for the next generation of X-ray space observatories. For operation under AC-bias, the TESs have to be carefully designed and optimized. In particular, the use of high aspect ratio devices will help to mitigate non-ideal behaviour due to the weak-link effect. In this paper, we present a full characterization of a TES array containing five different device geometries, with aspect ratios (width:length) ranging from 1:2 up to 1:6. The complex impedance of all geometries is measured in different bias configurations to study the evolution of the small-signal limit superconducting transition parameters, as well as the excess noise. We show that high aspect ratio devices with properly tuned critical temperatures (around 90 mK) can achieve excellent energy resolution, with an array average of 2.03 +- 0.17 eV at 5.9 keV and a best achieved resolution of 1.63 +- 0.17 eV. This demonstrates that AC-biased TESs can achieve a very competitive performance compared to DC-biased TESs. The results have motivated a push to even more extreme device geometries currently in development.
△ Less
Submitted 20 July, 2021;
originally announced July 2021.
-
Double-crystal measurements at the CERN SPS
Authors:
W. Scandale,
G. Arduini,
F. Cerutti,
M. D'Andrea,
L. S. Esposito,
M. Garattini,
S. Gilardoni,
D. Mirarchi,
S. Montesano,
A. Natochii,
S. Redaelli,
R. Rossi,
G. I. Smirnov,
L. Burmistrov,
S. Dubos,
V. Puill,
A. Stocchi,
F. Addesa,
F. Murtas,
F. Galluccio,
A. D. Kovalenko,
A. M. Taratin,
A. S. Denisov,
Yu. A. Gavrikov,
Yu. M. Ivanov
, et al. (13 additional authors not shown)
Abstract:
The UA9 setup, installed in the Super Proton Synchrotron (SPS) at CERN, was exploited for a proof of principle of the double-crystal scenario, proposed to measure the electric and the magnetic moments of short-lived baryons in a high-energy hadron collider, such as the Large Hadron Collider (LHC). Linear and angular actuators were used to position the crystals and establish the required beam confi…
▽ More
The UA9 setup, installed in the Super Proton Synchrotron (SPS) at CERN, was exploited for a proof of principle of the double-crystal scenario, proposed to measure the electric and the magnetic moments of short-lived baryons in a high-energy hadron collider, such as the Large Hadron Collider (LHC). Linear and angular actuators were used to position the crystals and establish the required beam configuration. Timepix detectors and high-sensitivity Beam Loss Monitors were exploited to observe the deflected beams. Linear and angular scans allowed exploring the particle interactions with the two crystals and recording their efficiency. The measured values of the beam trajectories, profiles and of the channeling efficiency agree with the results of a Monte-Carlo simulation.
△ Less
Submitted 26 March, 2021;
originally announced March 2021.
-
Reviewing two decades of energy system analysis with bibliometrics
Authors:
Dominik Franjo Dominković,
Jann Michael Weinand,
Fabian Scheller,
Matteo D'Andrea,
Russell McKenna
Abstract:
The field of Energy System Analysis (ESA) has experienced exponential growth in the number of publications since at least the year 2000. This paper presents a comprehensive bibliometric analysis on ESA by employing different algorithms in Matlab and R. The focus of results is on quantitative indicators relating to number and type of publication outputs, collaboration links between institutions, au…
▽ More
The field of Energy System Analysis (ESA) has experienced exponential growth in the number of publications since at least the year 2000. This paper presents a comprehensive bibliometric analysis on ESA by employing different algorithms in Matlab and R. The focus of results is on quantitative indicators relating to number and type of publication outputs, collaboration links between institutions, authors and countries, and dynamic trends within the field. The five and twelve most productive countries have 50% and 80% of ESA publications respectively. The dominant institutions are even more concentrated within a small number of countries. A significant concentration of published papers within countries and institutions was also confirmed by analysing collaboration networks. These show dominant collaboration within the same university or at least the same country. There is also is a strong link among the most successful journals, authors and institutions. The Energy journal has had the most publications in the field, and its editor-in-chief Lund H is the author with most of the publications in the field, as well as the author with most of the highly cited publications in the field. In terms of the dynamics within the field in the past decade, recent years have seen a higher impact of topics related to flexibility and hybrid/integrated energy systems alongside a decline in individual technologies. This paper provides a holistic overview of two decades' research output and enables interested readers to obtain a comprehensive overview of the key trends in this active field.
△ Less
Submitted 17 March, 2021;
originally announced March 2021.
-
TiAu TES 32$\times$32 pixel array: uniformity, thermal crosstalk and performance at different X-ray energies
Authors:
E. Taralli,
M. D'Andrea,
L. Gottardi,
K. Nagayoshi,
M. Ridder,
S. Visser,
M. de Wit,
D. Vaccaro,
H. Akamatsu,
K. Ravensberg,
R. Hoogeveen,
M. Bruijn,
J. R. Gao
Abstract:
Large format arrays of transition edge sensor (TES) are crucial for the next generation of X-ray space observatories. Such arrays are required to achieve an energy resolution of $\mathrmΔE<$3 eV full-width-half-maximum (FWHM) in the soft X-ray energy range. We are currently develo** X-ray microcalorimeter arrays as a backup option for the X-IFU instrument on board of ATHENA space telescope, led…
▽ More
Large format arrays of transition edge sensor (TES) are crucial for the next generation of X-ray space observatories. Such arrays are required to achieve an energy resolution of $\mathrmΔE<$3 eV full-width-half-maximum (FWHM) in the soft X-ray energy range. We are currently develo** X-ray microcalorimeter arrays as a backup option for the X-IFU instrument on board of ATHENA space telescope, led by ESA and foreseen to be launched in 2031. In this contribution, we report on the development and the characterization of a uniform 32$\times$32 pixel array with (length$\times $width) 140$\times$30 $μ$m$^2$ TiAu TESs, which have \textcolor{black}{a 2.3 $μ$m} thick Au absorber for X-ray photons. The pixels have a typical normal resistance $R_\mathrm{n}$ = 121 m$Ω$ and a critical temperature $T_\mathrm{c}\sim$ 90 mK. We performed extensive measurements on 60 pixels out of the array in order to show the uniformity of the array. We obtained an energy resolutions between 2.4 and 2.6 eV (FWHM) at 5.9 keV, measured in a single-pixel mode at AC bias frequencies ranging from 1 to 5 MHz, with a frequency domain multiplexing (FDM) readout system, which is developed at SRON/VTT. We also present the detector energy resolution at X-ray with different photon energies generated by a modulated external X-ray source from 1.45 keV up to 8.9 keV. Multiplexing readout across several pixels has also been performed to evaluate the impact of the thermal crosstalk to the instrument's energy resolution budget requirement. This value results in a derived requirement, for the first neighbour, that is less than 1$\times$10$^{-3}$ when considering the ratio between the amplitude of the crosstalk signal to an X-ray pulse (for example at 5.9 keV)
△ Less
Submitted 19 February, 2021;
originally announced February 2021.
-
Performance and uniformity of a kilo-pixel array of Ti/Au transition-edge sensor microcalorimeters
Authors:
E. Taralli,
M. D'Andrea,
L. Gottardi,
K. Nagayoshi,
M. L. Ridder,
M. de Wit,
D. Vaccaro,
H. Akamatsu,
M. P. Bruijn,
J. R. Gao
Abstract:
Uniform large transition-edge sensor (TES) arrays are fundamental for the next generation of X-ray space observatories. These arrays are required to achieve an energy resolution $ΔE$ < 3 eV full-width-half-maximum (FWHM) in the soft X-ray energy range. We are currently develo** X-ray microcalorimeter arrays for use in future laboratory and space-based X-ray astrophysics experiments and ground-ba…
▽ More
Uniform large transition-edge sensor (TES) arrays are fundamental for the next generation of X-ray space observatories. These arrays are required to achieve an energy resolution $ΔE$ < 3 eV full-width-half-maximum (FWHM) in the soft X-ray energy range. We are currently develo** X-ray microcalorimeter arrays for use in future laboratory and space-based X-ray astrophysics experiments and ground-based spectrometers.
In this contribution we report on the development and the characterization of a uniform 32$\times$32 pixel array with 140$\times$30 $μ$m$^2$ Ti/Au TESs with Au X-ray absorber. We report upon extensive measurements on 60 pixels in order to show the uniformity of our large TES array. The averaged critical temperature is $T_\mathrm{c}$ = 89.5$\pm$0.5 mK and the variation across the array ($\sim$1 cm) is less than 1.5 mK. We found a large region of detector's bias points between 20\% and 40\% of the normal-state resistance where the energy resolution is constantly lower than 3 eV. In particular, results show a summed X-ray spectral resolution $ΔE_\mathrm{FWHM}$ = 2.50$\pm$0.04 eV at a photon energy of 5.9 keV, measured in a single-pixel mode using a frequency domain multiplexing (FDM) readout system developed at SRON/VTT at bias frequencies ranging from 1 to 5 MHz. Moreover we compare the logarithmic resistance sensitivity with respect to temperature and current ($α$ and $β$ respectively) and their correlation with the detector's noise parameter $M$, showing an homogeneous behaviour for all the measured pixels in the array.
△ Less
Submitted 18 February, 2021;
originally announced February 2021.
-
Single pixel performance of a 32$\times$32 Ti/Au TES array with broadband X-ray spectra
Authors:
Matteo D'Andrea,
Emanuele Taralli,
Hiroki Akamatsu,
Luciano Gottardi,
Kenichiro Nagayoshi,
Kevin Ravensberg,
Marcel L. Ridder,
Davide Vaccaro,
Cor P. de Vries,
Martin de Wit,
Marcel P. Bruijn,
Ruud W. M. Hoogeveen,
Jian-Rong Gao
Abstract:
We are develo** a kilo-pixels Ti/Au TES array as a backup option for Athena X-IFU. Here we report on single-pixel performance of a 32$\times$32 array operated in a Frequency Division Multiplexing (FDM) readout system, with bias frequencies in the range 1-5 MHz. We have tested the pixels response at several photon energies, by means of a $^{55}$Fe radioactive source (emitting Mn-K$α$ at 5.9 keV)…
▽ More
We are develo** a kilo-pixels Ti/Au TES array as a backup option for Athena X-IFU. Here we report on single-pixel performance of a 32$\times$32 array operated in a Frequency Division Multiplexing (FDM) readout system, with bias frequencies in the range 1-5 MHz. We have tested the pixels response at several photon energies, by means of a $^{55}$Fe radioactive source (emitting Mn-K$α$ at 5.9 keV) and a Modulated X-ray Source (MXS, providing Cr-K$α$ at 5.4 keV and Cu-K$α$ at 8.0 keV). First, we report the procedure used to perform the detector energy scale calibration, usually achieving a calibration accuracy better than $\sim$ 0.5 eV in the 5.4 - 8.9 keV energy range. Then, we present the measured energy resolution at the different energies (best single pixel performance: $Δ$E$_{FWHM}$ = 2.40 $\pm$ 0.09 eV @ 5.4 keV; 2.53 $\pm$ 0.10 eV @ 5.9 keV; 2.78 $\pm$ 0.16 eV @ 8.0 keV), investigating also the performance dependency from the pixel bias frequency and the count rate. Thanks to long background measurements ($\sim$ 1 day), we finally detected also the Al-K$α$ line at 1.5 keV, generated by fluorescence inside the experimental setup. We analyzed this line to obtain a first assessment of the single-pixel performance also at low energy ($Δ$E$_{FWHM}$ = 1.91 eV $\pm$ 0.21 eV @ 1.5 keV), and to evaluate the linearity of the detector response in a large energy band (1.5 - 8.9 keV).
△ Less
Submitted 16 February, 2021;
originally announced February 2021.
-
Frequency Shift Algorithm: Application to a Frequency-Domain Multiplexing Readout of X-ray Transition-Edge Sensor Microcalorimeters
Authors:
D. Vaccaro,
H. Akamatsu,
J. van der Kuur,
P. van der Hulst,
A. C. T. Nieuwenhuizen,
P. van Winden,
L. Gottardi,
R. den Hartog,
M. P. Bruijn,
M. D'Andrea,
J. R. Gao,
J. W. A. den Herder,
R. W. M. Hoogeveen,
B. Jackson,
A. J. van der Linden,
K. Nagayoshi,
K. Ravensberg,
M. L. Ridder,
E. Taralli,
M. de Wit
Abstract:
In the frequency-domain multiplexing (FDM) scheme, transition-edge sensors (TES) are individually coupled to superconducting LC filters and AC biased at MHz frequencies through a common readout line. To make efficient use of the available readout bandwidth and to minimize the effect of non-linearities, the LC resonators are usually designed to be on a regular grid. The lithographic processes howev…
▽ More
In the frequency-domain multiplexing (FDM) scheme, transition-edge sensors (TES) are individually coupled to superconducting LC filters and AC biased at MHz frequencies through a common readout line. To make efficient use of the available readout bandwidth and to minimize the effect of non-linearities, the LC resonators are usually designed to be on a regular grid. The lithographic processes however pose a limit on the accuracy of the effective filter resonance frequencies. Off-resonance bias carriers could be used to suppress the impact of intermodulation distortions, which nonetheless would significantly affect the effective bias circuit and the detector spectral performance. In this paper we present a frequency shift algorithm (FSA) to allow off-resonance readout of TES's while preserving the on-resonance bias circuit and spectral performance, demonstrating its application to the FDM readout of a X-ray TES microcalorimeter array. We discuss the benefits in terms of mitigation of the impact of intermodulation distortions at the cost of increased bias voltage and the scalability of the algorithm to multi-pixel FDM readout. We show that with FSA, in multi-pixel and frequencies shifted on-grid, the line noises due to intermodulation distortion are placed away from the sensitive region in the TES response and the X-ray performance is consistent with the single-pixel, on-resonance level.
△ Less
Submitted 11 February, 2021;
originally announced February 2021.
-
Review of the particle background of the Athena X-IFU instrument
Authors:
Simone Lotti,
Matteo D'Andrea,
Silvano Molendi,
Claudio Macculi,
Gabriele Minervini,
Valentina Fioretti,
Monica Laurenza,
Christian Jacquey,
Luigi Piro
Abstract:
X-ray observations are limited by the background, due to intrinsic faintness or diffuse nature of the sources. The future Athena X-ray observatory has among its goals the characterization of these sources. We aim at characterizing the particle-induced background of the Athena microcalorimeter, in both its low (Soft Protons) and high (GCR) energy induced components, to assess the instrument capabil…
▽ More
X-ray observations are limited by the background, due to intrinsic faintness or diffuse nature of the sources. The future Athena X-ray observatory has among its goals the characterization of these sources. We aim at characterizing the particle-induced background of the Athena microcalorimeter, in both its low (Soft Protons) and high (GCR) energy induced components, to assess the instrument capability to characterize background dominated sources such as the outskirts of clusters of galaxies. We compare two radiation environments, namely the L1 and L2 Lagrangian points, and derive indications against the latter. We estimate the particle-induced background level on the X-IFU microcalorimeter with Monte Carlo simulations, before and after all the solutions adopted to reduce its level. Concerning the GCR induced component the background level is compliant with the mission requirement. Regarding the Soft Protons component, the analysis does not predict dramatically different backgrounds in the L1 and L2 orbits. However, the lack of data concerning the L2 environment labels it as very weakly characterizable, and thus we advise against its choice as orbit for X-ray missions. We then use these background levels to simulate the observation of a typical galaxy cluster from its center out to 1.2 R200 to probe the characterization capabilities of the instrument out to the outskirts. We find that without any background reduction it is not possible to characterize the properties of the cluster in the outer regions. We also find no improvement of the observations when carried out during the solar maximum with respect to the solar minimum conditions.
△ Less
Submitted 7 January, 2021;
originally announced January 2021.
-
The Demonstration Model of the ATHENA X-IFU Cryogenic AntiCoincidence Detector
Authors:
Matteo D'Andrea,
Claudio Macculi,
Guido Torrioli,
Andrea Argan,
Daniele Brienza,
Simone Lotti,
Gabriele Minervini,
Luigi Piro,
Michele Biasotti,
Lorenzo Ferrari Barusso,
Flavio Gatti,
Manuela Rigano,
Angela Volpe,
Elia Stefano Battistelli
Abstract:
The Cryogenic AntiCoincidence Detector (CryoAC) of ATHENA X-IFU is designed to reduce the particle background of the instrument and to enable the mission science goals. It is a 4 pixel silicon microcalorimeter sensed by an Ir/Au TES network. We have developed the CryoAC Demonstration Model, a prototype aimed to probe the critical technologies of the detector, i.e. the suspended absorber with an ac…
▽ More
The Cryogenic AntiCoincidence Detector (CryoAC) of ATHENA X-IFU is designed to reduce the particle background of the instrument and to enable the mission science goals. It is a 4 pixel silicon microcalorimeter sensed by an Ir/Au TES network. We have developed the CryoAC Demonstration Model, a prototype aimed to probe the critical technologies of the detector, i.e. the suspended absorber with an active area of 1 cm2; the low energy threshold of 20 keV; and the operation connected to a 50 mK thermal bath with a power dissipation less than 40 nW. Here we report the test performed on the first CryoAC DM sample (namely the AC-S10 prototype), showing that it is fully compliant with its requirements.
△ Less
Submitted 13 December, 2019;
originally announced December 2019.
-
Radiation reaction, over-reaction, and under-reaction
Authors:
Mario D'Andrea,
Markus A. Luty,
Christopher B. Verhaaren
Abstract:
The subject of radiation reaction in classical electromagnetism remains controversial over 120 years after the pioneering work of Lorentz. We give a simple but rigorous treatment of the subject at the textbook level that explains the apparent paradoxes that are much discussed in the literature on the subject. We first derive the equation of motion of a charged particle from conservation of energy…
▽ More
The subject of radiation reaction in classical electromagnetism remains controversial over 120 years after the pioneering work of Lorentz. We give a simple but rigorous treatment of the subject at the textbook level that explains the apparent paradoxes that are much discussed in the literature on the subject. We first derive the equation of motion of a charged particle from conservation of energy and momentum, which includes the self-force term. We then show that this theory is unstable if charged particles are pointlike: the energy is unbounded from below, and charged particles self-accelerate (`over-react') due to their negative `bare' mass. This theory clearly does not describe our world, but we show that these instabilities are absent if the particle has a finite size larger than its classical radius. For such finite-size charged particles, the effects of radiation reaction can be computed in a systematic expansion in the size of the particle. The leading term in this expansion is the reduced-order Abraham-Lorentz equation of motion, which has no stability problems. We also discuss the apparent paradox that a particle with constant acceleration radiates, but does not suffer radiation reaction (`under-reaction'). Along the way, we introduce the ideas of renormalization and effective theories, which are important in many areas of modern theoretical physics. We hope that this will be a useful addition to the literature that will remove some of the air of mystery and paradox surrounding the subject.
△ Less
Submitted 3 September, 2019;
originally announced September 2019.
-
Opening the low-background and high-spectral-resolution domain with the ATHENA large X-ray observatory: Development of the Cryogenic AntiCoincidence Detector for the X-ray Integral Field Unit
Authors:
Matteo D'Andrea
Abstract:
ATHENA is a large-class ESA mission selected for launch in 2031. It is designed to address the science theme "The Hot and Energetic Universe", performing X-ray observations (0.2-12 keV) at the L2 Sun-Earth Lagrangian point. The X-IFU is one of the two instruments of the payload. It is a cryogenic spectrometer providing spatially resolved high-resolution spectroscopy. The core of the instrument is…
▽ More
ATHENA is a large-class ESA mission selected for launch in 2031. It is designed to address the science theme "The Hot and Energetic Universe", performing X-ray observations (0.2-12 keV) at the L2 Sun-Earth Lagrangian point. The X-IFU is one of the two instruments of the payload. It is a cryogenic spectrometer providing spatially resolved high-resolution spectroscopy. The core of the instrument is a large array of TES microcalorimeters, operated at a 50 mK thermal bath. The X-IFU performances would be strongly degraded by the particle background expected in the L2 environment, thus advanced reduction techniques have been adopted to reduce this contribution by a factor $\sim$50. This is needed to enable many core science objectives of the mission. Most of the background reduction ($\sim 80\%$) is achieved thanks to the Cryogenic AntiCoincidence detector (CryoAC), a 4 pixels TES microcalorimeter which will be placed less than 1 mm below the TES array. The CryoAC is a sort of instrument-inside-the-instrument, with independent cold and warm electronics and a dedicated data processing chain. To reach the required particle rejection efficiency ($\sim 98 \%$) it will have a wide energy band (from 20 keV to $\sim$ 1 MeV) and a low deadtime ($< \sim 2\%$), while respecting several constraints to ensure mechanical, thermal and electromagnetic compatibility with the TES array. Here I will report my PhD research activity, which has been focused on the development of the CryoAC Demonstration Model (DM), a single pixel detector requested by ESA before the mission adoption. The thesis is divided in two main parts. In the first one I will mainly present the astrophysical framework of my research, and in the second one I will focus on the experimental activities carried out towards the CryoAC DM development.
△ Less
Submitted 5 April, 2019;
originally announced April 2019.
-
The Cryogenic AntiCoincidence detector for ATHENA X-IFU: improvement of the test setup towards the Demonstration Model
Authors:
Matteo D'Andrea,
Claudio Macculi,
Andrea Argan,
Simone Lotti,
Gabriele Minervini,
Luigi Piro,
Michele Biasotti,
Dario Corsini,
Flavio Gatti,
Guido Torrioli,
Angela Volpe
Abstract:
The ATHENA X-IFU development program foresees to build and characterize an instrument Demonstration Model (DM), in order to probe the system critical technologies before the mission adoption. In this respect, we are now develo** the DM of the X-IFU Cryogenic Anticoincidence Detector (CryoAC), which will be delivered to the Focal Plane Assembly (FPA) development team for the integration with the…
▽ More
The ATHENA X-IFU development program foresees to build and characterize an instrument Demonstration Model (DM), in order to probe the system critical technologies before the mission adoption. In this respect, we are now develo** the DM of the X-IFU Cryogenic Anticoincidence Detector (CryoAC), which will be delivered to the Focal Plane Assembly (FPA) development team for the integration with the TES array. Before the delivery, we will characterize and test the CryoAC DM in our CryoLab at INAF/IAPS. In this paper we report the main results of the activities performed to improve our cryogenic test setup, making it suitable for the DM integration. These activities mainly consist in the development of a mechanichal setup and a cryogenic magnetic shielding system, whose effectiveness has been assessed by FEM simulations and a measurement at warm. The preliminary performance test has been performed by means of the last CryoAC single pixel prototype, the AC-S8 pre-DM sample.
△ Less
Submitted 23 July, 2018;
originally announced July 2018.
-
The Cryogenic AntiCoincidence detector for ATHENA X-IFU: assessing the role of the athermal phonons collectors in the AC-S8 prototype
Authors:
Matteo D'Andrea,
Claudio Macculi,
Andrea Argan,
Simone Lotti,
Gabriele Minervini,
Luigi Piro,
Michele Biasotti,
Dario Corsini,
Flavio Gatti,
Guido Torrioli
Abstract:
The ATHENA X-ray Observatory is the second large-class mission in the ESA Cosmic Vision 2015-2025 science programme. One of the two on-board instruments is the X-IFU, an imaging spectrometer based on a large array of TES microcalorimeters. To reduce the particle-induced background, the spectrometer works in combination with a Cryogenic Anticoincidence detector (CryoAC), placed less than 1 mm below…
▽ More
The ATHENA X-ray Observatory is the second large-class mission in the ESA Cosmic Vision 2015-2025 science programme. One of the two on-board instruments is the X-IFU, an imaging spectrometer based on a large array of TES microcalorimeters. To reduce the particle-induced background, the spectrometer works in combination with a Cryogenic Anticoincidence detector (CryoAC), placed less than 1 mm below the TES array. The last CryoAC single-pixel prototypes, namely AC-S7 and AC-S8, are based on large area (1 cm2) Silicon absorbers sensed by 65 parallel-connected iridium TES. This design has been adopted to improve the response generated by the athermal phonons, which will be used as fast anticoincidence flag. The latter sample is featured also with a network of Aluminum fingers directly connected to the TES, designed to further improve the athermals collection efficiency. In this paper we will report the main results obtained with AC-S8, showing that the additional fingers network is able to increase the energy collected from the athermal part of the pulses (from the 6% of AC-S7 up to the 26 % with AC-S8). Furthermore, the finger design is able to prevent the quasiparticle recombination in the aluminum, assuring a fast pulse rising front (L/R limited). In our road map, the AC-S8 prototype is the last step before the development of the CryoAC Demonstration Model (DM), which will be the detector able to demonstrate the critical technologies expected in the CryoAC development programme.
△ Less
Submitted 23 July, 2018;
originally announced July 2018.
-
The Cryogenic Anticoincidence Detector for ATHENA X-IFU: Preliminary test of AC-S9 towards the Demonstration Model
Authors:
Matteo D'Andrea,
Claudio Macculi,
Andrea Argan,
Simone Lotti,
Gabriele Minervini,
Luigi Piro,
Michele Biasotti,
Valentina Ceriale,
Giovanni Gallucci,
Flavio Gatti,
Guido Torrioli,
Angela Volpe
Abstract:
Our team is develo** the Cryogenic Anticoincidence Detector (CryoAC) of the ATHENA X-ray Integral Field Unit (X-IFU). It is a 4-pixels TES-based detector, which will be placed less than 1 mm below the main TES array detector. We are now producing the CryoAC Demonstration Model (DM): a single pixel prototype able to probe the detector critical technologies, i.e. the operation at 50 mK thermal bat…
▽ More
Our team is develo** the Cryogenic Anticoincidence Detector (CryoAC) of the ATHENA X-ray Integral Field Unit (X-IFU). It is a 4-pixels TES-based detector, which will be placed less than 1 mm below the main TES array detector. We are now producing the CryoAC Demonstration Model (DM): a single pixel prototype able to probe the detector critical technologies, i.e. the operation at 50 mK thermal bath, the threshold energy at 20 keV and the reproducibility of the thermal conductance between the suspended absorber and the thermal bath. This detector will be integrated and tested in our cryogenic setup at INAF/IAPS, and then delivered to SRON for the integration in the X-IFU Focal Plane Assemby (FPA) DM.
In this paper we report the status of the CryoAC DM development, showing the main result obtained with the last developed prototype, namely AC-S9. This is a DM-like sample, which we have preliminary integrated and tested before performing the final etching process to suspend the silicon absorber. The results are promising for the DM, since despite the limitations due to the absence of the final etching (high thermal capacity, high thermal conductance, partial TES surface coverage), we have been able to operate the detector with TB = 50 mK and to detect 6 keV photons, thus having a low energy threshold fully compatible with our requirement (20 keV).
△ Less
Submitted 11 July, 2018; v1 submitted 6 July, 2018;
originally announced July 2018.
-
The Cryogenic AntiCoincidence detector for ATHENA X-IFU: a scientific assessment of the observational capabilities in the hard X-ray band
Authors:
Matteo D'Andrea,
Simone Lotti,
Claudio Macculi,
Luigi Piro,
Andrea Argan,
Flavio Gatti
Abstract:
ATHENA is a large X-ray observatory, planned to be launched by ESA in 2028 towards an L2 orbit. One of the two instruments of the payload is the X-IFU: a cryogenic spectrometer based on a large array of TES microcalorimeters, able to perform integral field spectrography in the 0.2-12 keV band (2.5 eV FWHM at 6 keV). The X-IFU sensitivity is highly degraded by the particle background expected in th…
▽ More
ATHENA is a large X-ray observatory, planned to be launched by ESA in 2028 towards an L2 orbit. One of the two instruments of the payload is the X-IFU: a cryogenic spectrometer based on a large array of TES microcalorimeters, able to perform integral field spectrography in the 0.2-12 keV band (2.5 eV FWHM at 6 keV). The X-IFU sensitivity is highly degraded by the particle background expected in the L2 orbit, which is induced by primary protons of both galactic and solar origin, and mostly by secondary electrons. To reduce the particle background level and enable the mission science goals, the instrument incorporates a Cryogenic AntiCoincidence detector (CryoAC). It is a 4 pixel TES based detector, placed <1 mm below the main array. In this paper we report a scientific assessment of the CryoAC observational capabilities in the hard X-ray band (E>10 keV). The aim of the study has been to understand if the present detector design can be improved in order to enlarge the X-IFU scientific capability on an energy band wider than the TES array. This is beyond the CryoAC baseline, being this instrument aimed to operate as anticoincidence particle detector and not conceived to perform X-ray observations.
△ Less
Submitted 19 May, 2017;
originally announced May 2017.
-
The particle background of the X-IFU instrument
Authors:
Simone Lotti,
Teresa Mineo,
Christian Jacquey,
Silvano Molendi,
Matteo D'Andrea,
Claudio Macculi,
Luigi Piro
Abstract:
In this paper we are going to review the latest estimates for the particle background expected on the X-IFU instrument onboard of the ATHENA mission. The particle background is induced by two different particle populations: the so called "soft protons" and the Cosmic rays. The first component is composed of low energy particles (< 100s keV) that get funnelled by the mirrors towards the focal plane…
▽ More
In this paper we are going to review the latest estimates for the particle background expected on the X-IFU instrument onboard of the ATHENA mission. The particle background is induced by two different particle populations: the so called "soft protons" and the Cosmic rays. The first component is composed of low energy particles (< 100s keV) that get funnelled by the mirrors towards the focal plane, losing part of their energy inside the filters and inducing background counts inside the instrument sensitivity band. The latter component is induced by high energy particles (> 100 MeV) that possess enough energy to cross the spacecraft and reach the detector from any direction, depositing a small fraction of their energy inside the instrument. Both these components are estimated using Monte Carlo simulations and the latest results are presented here.
△ Less
Submitted 11 May, 2017;
originally announced May 2017.
-
Updates on the background estimates for the X-IFU instrument onboard of the ATHENA mission
Authors:
Simone Lotti,
Claudio Macculi,
Matteo D'Andrea,
Luigi Piro,
Silvano Molendi,
Fabio Gastaldello,
Teresa Mineo,
Antonino D'Ai,
Andrea Bulgarelli,
Valentina Fioretti,
Christian Jacquey,
Monica Laurenza,
Philippe Laurent
Abstract:
ATHENA, with a launch foreseen in 2028 towards the L2 orbit, addresses the science theme "The Hot and Energetic Universe", coupling a high-performance X-ray Telescope with two complementary focal-plane instruments. One of these, the X-ray Integral Field Unit (X-IFU) is a TES based kilo-pixel array providing spatially resolved high-resolution spectroscopy (2.5 eV at 6 keV) over a 5 arcmin FoV. The…
▽ More
ATHENA, with a launch foreseen in 2028 towards the L2 orbit, addresses the science theme "The Hot and Energetic Universe", coupling a high-performance X-ray Telescope with two complementary focal-plane instruments. One of these, the X-ray Integral Field Unit (X-IFU) is a TES based kilo-pixel array providing spatially resolved high-resolution spectroscopy (2.5 eV at 6 keV) over a 5 arcmin FoV. The background for this kind of detectors accounts for several components: the diffuse Cosmic X-ray Background, the low energy particles (<~100 keV) focalized by the mirrors and reaching the detector from inside the field of view, and the high energy particles (>~100 MeV) crossing the spacecraft and reaching the focal plane from every direction. Each one of these components is under study to reduce their impact on the instrumental performances. This task is particularly challenging, given the lack of data on the background of X-ray detectors in L2, the uncertainties on the particle environment to be expected in such orbit, and the reliability of the models used in the Monte Carlo background computations. As a consequence, the activities addressed by the group range from the reanalysis of the data of previous missions like XMM-Newton, to the characterization of the L2 environment by data analysis of the particle monitors onboard of satellites present in the Earth magnetotail, to the characterization of solar events and their occurrence, and to the validation of the physical models involved in the Monte Carlo simulations. All these activities will allow to develop a set of reliable simulations to predict, analyze and find effective solutions to reduce the particle background experienced by the X-IFU, ultimately satisfying the scientific requirement that enables the science of ATHENA. While the activities are still ongoing, we present here some preliminary results already obtained by the group.
△ Less
Submitted 27 April, 2017;
originally announced April 2017.
-
Gravitational waves emitted by extrasolar planetary systems
Authors:
Valeria Ferrari,
Marco D'Andrea,
Emanuele Berti
Abstract:
In this paper we consider the Extra-solar Planetary Systems recently discovered in our Galaxy as potential sources of gravitational waves. We estimate the frequency and characteristic amplitude of the radiation they emit due to the orbital motion, using the quadrupole formalism. In addition, we check whether the conditions needed for the resonant excitation of the f- and g-modes of the central s…
▽ More
In this paper we consider the Extra-solar Planetary Systems recently discovered in our Galaxy as potential sources of gravitational waves. We estimate the frequency and characteristic amplitude of the radiation they emit due to the orbital motion, using the quadrupole formalism. In addition, we check whether the conditions needed for the resonant excitation of the f- and g-modes of the central star can be fulfilled. By a Roche-lobe analysis, we show that there could exist systems in which the low-order g-modes could be excited, although this does not happen in the systems discovered up to now.
△ Less
Submitted 30 November, 2000; v1 submitted 26 January, 2000;
originally announced January 2000.