-
Discrete symmetries tested at 10$^{-4}$ precision using linear polarization of photons from positronium annihilations
Authors:
Paweł Moskal,
Eryk Czerwiński,
Juhi Raj,
Steven D. Bass,
Ermias Y. Beyene,
Neha Chug,
Aurélien Coussat,
Catalina Curceanu,
Meysam Dadgar,
Manish Das,
Kamil Dulski,
Aleksander Gajos,
Marek Gorgol,
Beatrix C. Hiesmayr,
Bożena Jasińska,
Krzysztof Kacprzak,
Tevfik Kaplanoglu,
Łukasz Kapłon,
Konrad Klimaszewski,
Paweł Konieczka,
Grzegorz Korcyl,
Tomasz Kozik,
Wojciech Krzemień,
Deepak Kumar,
Simbarashe Moyo
, et al. (16 additional authors not shown)
Abstract:
Discrete symmetries play an important role in particle physics with violation of CP connected to the matter-antimatter imbalance in the Universe. We report the most precise test of P, T and CP invariance in decays of ortho-positronium, performed with methodology involving polarization of photons from these decays. Positronium, the simplest bound state of an electron and positron, is of recent inte…
▽ More
Discrete symmetries play an important role in particle physics with violation of CP connected to the matter-antimatter imbalance in the Universe. We report the most precise test of P, T and CP invariance in decays of ortho-positronium, performed with methodology involving polarization of photons from these decays. Positronium, the simplest bound state of an electron and positron, is of recent interest with discrepancies reported between measured hyperfine energy structure and theory at the level of $10^{-4}$ signaling a need for better understanding of the positronium system at this level. We test discrete symmetries using photon polarizations determined via Compton scattering in the dedicated J-PET tomograph on an event-by-event basis and without the need to control the spin of the positronium with an external magnetic field, in contrast to previous experiments. Our result is consistent with QED expectations at the level of 0.0007 and one standard deviation.
△ Less
Submitted 22 January, 2024;
originally announced January 2024.
-
Feasibility studies for imaging e$^{+}$e$^{-}$ annihilation with modular multi-strip detectors
Authors:
S. Sharma,
L. Povolo,
S. Mariazzi,
G. Korcyl,
K. Kacprzak,
D. Kumar,
S. Niedzwiecki,
J. Baran,
E. Beyene,
R. S. Brusa,
R. Caravita,
N. Chug,
A. Coussat,
C. Curceanu,
E. Czerwinski,
M. Dadgar,
M. Das,
K. Dulski,
K. Eliyan,
A. Gajos,
N. Gupta,
B. C. Hiesmayr,
L. Kaplon,
T. Kaplanoglu,
K. Klimaszewski
, et al. (19 additional authors not shown)
Abstract:
Studies based on imaging the annihilation of the electron (e$^{-}$) and its antiparticle positron (e$^{+}$) open up several interesting applications in nuclear medicine and fundamental research. The annihilation process involves both the direct conversion of e$^{+}$e$^{-}$ into photons and the formation of their atomically bound state, the positronium atom (Ps), which can be used as a probe for fu…
▽ More
Studies based on imaging the annihilation of the electron (e$^{-}$) and its antiparticle positron (e$^{+}$) open up several interesting applications in nuclear medicine and fundamental research. The annihilation process involves both the direct conversion of e$^{+}$e$^{-}$ into photons and the formation of their atomically bound state, the positronium atom (Ps), which can be used as a probe for fundamental studies. With the ability to produce large quantities of Ps, manipulate them in long-lived Ps states, and image their annihilations after a free fall or after passing through atomic interferometers, this purely leptonic antimatter system can be used to perform inertial sensing studies in view of a direct test of Einstein equivalence principle. It is envisioned that modular multistrip detectors can be exploited as potential detection units for this kind of studies. In this work, we report the results of the first feasibility study performed on a e$^{+}$ beamline using two detection modules to evaluate their reconstruction performance and spatial resolution for imaging e$^{+}$e$^{-}$ annihilations and thus their applicability for gravitational studies of Ps.
△ Less
Submitted 12 September, 2023;
originally announced September 2023.
-
Comparative studies of the sensitivities of sparse and full geometries of Total-Body PET scanners built from crystals and plastic scintillators
Authors:
Meysam Dadgar,
Szymon Parzych,
Jakub Baran,
Neha Chug,
Catalina Curceanu,
Eryk Czerwiński,
Kamil Dulski,
Kavya Elyan,
Aleksander Gajos,
Beatrix Hiesmayr,
Łukasz Kapłon,
Konrad Klimaszewski,
Paweł Konieczka,
Grzegorz Korcyl,
Tomasz Kozik,
Wojciech Krzemień,
Deepak Kumar,
Szymon Niedźwiecki,
Domonik Panek,
Eleną Perez del Rio,
Lech Raczyński,
Sushil Sharma,
Shivani,
Roman Shopa,
Magdalena Skurzok
, et al. (6 additional authors not shown)
Abstract:
Background: Total-Body imaging offers high sensitivity, single-bed position, and low dose, but high construction costs limit worldwide utilization. This study compares existing and develo** tomographs using plastic scintillators via simulations to propose a cost-efficient Total-Body PET scanner.
Methods: Simulations of eight uEXPLORER tomographs with different scintillator materials, axial fie…
▽ More
Background: Total-Body imaging offers high sensitivity, single-bed position, and low dose, but high construction costs limit worldwide utilization. This study compares existing and develo** tomographs using plastic scintillators via simulations to propose a cost-efficient Total-Body PET scanner.
Methods: Simulations of eight uEXPLORER tomographs with different scintillator materials, axial field-of-view, and detector configuration, and eight J-PET scanners with various field-of-view, plastic scintillator cross-sections, and layers were performed. Biograph Vision was also simulated. Two types of simulations were conducted with a central source and a water-filled phantom.
Results: BGO crystal-based scanners showed the best sensitivity (350 cps/kBq at the center). Sparse geometry or LYSO crystals reduced sensitivity. J-PET design showed similar sensitivity to sparse LYSO detectors, with full body coverage and additional gain for brain imaging.
Conclusion: The J-PET tomography system using plastic scintillators could be a cost-efficient alternative for Total-Body PET scanners, overcoming high construction costs while maintaining sensitivity
△ Less
Submitted 12 April, 2023;
originally announced April 2023.
-
Feasibility of the J-PET to monitor range of therapeutic proton beams
Authors:
Jakub Baran,
Damian Borys,
Karol Brzeziński,
Jan Gajewski,
Michał Silarski,
Neha Chug,
Aurélien Coussat,
Eryk Czerwiński,
Meysam Dadgar,
Kamil Dulski,
Kavya V. Eliyan,
Aleksander Gajos Krzysztof Kacprzak,
Łukasz Kapłon,
Konrad Klimaszewski,
Paweł Konieczka,
Renata Kopeć,
Grzegorz Korcyl,
Tomasz Kozik,
Wojciech Krzemień,
Deepak Kumar,
Antony J. Lomax,
Keegan McNamara,
Szymon Niedźwiecki,
Paweł Olko,
Dominik Panek
, et al. (18 additional authors not shown)
Abstract:
Objective: The aim of this work is to investigate the feasibility of the Jagiellonian Positron Emission Tomography (J-PET) scanner for intra-treatment proton beam range monitoring. Approach: The Monte Carlo simulation studies with GATE and PET image reconstruction with CASToR were performed in order to compare six J-PET scanner geometries (three dual-heads and three cylindrical). We simulated prot…
▽ More
Objective: The aim of this work is to investigate the feasibility of the Jagiellonian Positron Emission Tomography (J-PET) scanner for intra-treatment proton beam range monitoring. Approach: The Monte Carlo simulation studies with GATE and PET image reconstruction with CASToR were performed in order to compare six J-PET scanner geometries (three dual-heads and three cylindrical). We simulated proton irradiation of a PMMA phantom with a Single Pencil Beam (SPB) and Spread-Out Bragg Peak (SOBP) of various ranges. The sensitivity and precision of each scanner were calculated, and considering the setup's cost-effectiveness, we indicated potentially optimal geometries for the J-PET scanner prototype dedicated to the proton beam range assessment. Main results: The investigations indicate that the double-layer cylindrical and triple-layer double-head configurations are the most promising for clinical application. We found that the scanner sensitivity is of the order of 10$^{-5}$ coincidences per primary proton, while the precision of the range assessment for both SPB and SOBP irradiation plans was found below 1 mm. Among the scanners with the same number of detector modules, the best results are found for the triple-layer dual-head geometry. Significance: We performed simulation studies demonstrating that the feasibility of the J-PET detector for PET-based proton beam therapy range monitoring is possible with reasonable sensitivity and precision enabling its pre-clinical tests in the clinical proton therapy environment. Considering the sensitivity, precision and cost-effectiveness, the double-layer cylindrical and triple-layer dual-head J-PET geometry configurations seem promising for the future clinical application. Experimental tests are needed to confirm these findings.
△ Less
Submitted 28 February, 2023;
originally announced February 2023.
-
Testing Discrete Symmetries in Ortho-Positronium Decays with the J-PET Detector
Authors:
Eryk Czerwiński
Abstract:
A first result related to a CPT test in the decay of ortho-positronium based on data collected by means of the J-PET detector is already available, and a new test of CP symmetry is under investigation. Both results are based on the determination of angular correlations between momenta of gamma rays and other vector properties of the investigated system. Here, arguments for the possible usage of da…
▽ More
A first result related to a CPT test in the decay of ortho-positronium based on data collected by means of the J-PET detector is already available, and a new test of CP symmetry is under investigation. Both results are based on the determination of angular correlations between momenta of gamma rays and other vector properties of the investigated system. Here, arguments for the possible usage of data collected by the J-PET group to test CPT symmetry within the Standard-Model Extension framework are shortly presented.
△ Less
Submitted 8 February, 2023;
originally announced February 2023.
-
TOF MLEM Adaptation for the Total-Body J-PET with a Realistic Analytical System Response Matrix
Authors:
R. Y. Shopa,
J. Baran,
K. Klimaszewski,
W. Krzemień,
L. Raczyński,
W. Wiślicki,
K. Brzeziński,
N. Chug,
A. Coussat,
C. Curceanu,
E. Czerwiński,
M. Dadgar,
K. Dulski,
J. Gajewski,
A. Gajos,
B. C. Hiesmayr,
E. Kavya Valsan,
G. Korcyl,
T. Kozik,
D. Kumar,
Ł. Kapłon,
G. Moskal,
S. Niedźwiecki,
D. Panek,
S. Parzych
, et al. (10 additional authors not shown)
Abstract:
We report a study of the original image reconstruction algorithm based on the time-of-flight maximum likelihood expectation maximisation (TOF MLEM), developed for the total-body (TB) Jagiellonian PET (J-PET) scanners. The method is applicable to generic cylindrical or modular multi-layer layouts and is extendable to multi-photon imaging. The system response matrix (SRM) is represented as a set of…
▽ More
We report a study of the original image reconstruction algorithm based on the time-of-flight maximum likelihood expectation maximisation (TOF MLEM), developed for the total-body (TB) Jagiellonian PET (J-PET) scanners. The method is applicable to generic cylindrical or modular multi-layer layouts and is extendable to multi-photon imaging. The system response matrix (SRM) is represented as a set of analytical functions, uniquely defined for each pair of plastic scintillator strips used for the detection. A realistic resolution model (RM) in detector space is derived from fitting the Monte Carlo simulated emissions and detections of annihilation photons on oblique transverse planes. Additional kernels embedded in SRM account for TOF, parallax effect and axial smearing. The algorithm was tested on datasets, simulated in GATE for the NEMA IEC and static XCAT phantoms inside a 24-module 2-layer TB J-PET. Compared to the reference TOF MLEM with none or a shift-invariant RM, an improvement was observed, as evaluated by the analysis of image quality, difference images and ground truth metrics. We also reconstructed the data with additive contributions, pre-filtered geometrically and with non-TOF scatter correction applied. Despite some deterioration, the obtained results still capitalise on the realistic RM with better edge preservation and superior ground truth metrics. The envisioned prospects of the TOF MLEM with analytical SRM include its application in multi-photon imaging and further upgrade to account for the non-collinearity, positron range and other factors.
△ Less
Submitted 4 May, 2023; v1 submitted 6 February, 2023;
originally announced February 2023.
-
J-PET detection modules based on plastic scintillators for performing studies with positron and positronium beams
Authors:
S. Sharma,
J. Baran,
R. S. Brusa,
R. Caravita,
N. Chug,
A. Coussat,
C. Curceanu,
E. Czerwinski,
M. Dadgar,
K. Dulski,
K. Eliyan,
A. Gajos,
B. C. Hiesmayr,
K. Kacprzak,
L. Kaplon,
K. Klimaszewski,
P. Konieczka,
G. Korcyl,
T. Kozik,
W. Krzemien,
D. Kumar,
S. Mariazzi,
S. Niedzwiecki,
L. Panasa,
S. Parzych
, et al. (11 additional authors not shown)
Abstract:
The J-PET detector, which consists of inexpensive plastic scintillators, has demonstrated its potential in the study of fundamental physics. In recent years, a prototype with 192 plastic scintillators arranged in 3 layers has been optimized for the study of positronium decays. This allows performing precision tests of discrete symmetries (C, P, T) in the decays of positronium atoms. Moreover, than…
▽ More
The J-PET detector, which consists of inexpensive plastic scintillators, has demonstrated its potential in the study of fundamental physics. In recent years, a prototype with 192 plastic scintillators arranged in 3 layers has been optimized for the study of positronium decays. This allows performing precision tests of discrete symmetries (C, P, T) in the decays of positronium atoms. Moreover, thanks to the possibility of measuring the polarization direction of the photon based on Compton scattering, the predicted entanglement between the linear polarization of annihilation photons in positronium decays can also be studied. Recently, a new J-PET prototype was commissioned, based on a modular design of detection units. Each module consists of 13 plastic scintillators and can be used as a stand-alone, compact and portable detection unit. In this paper, the main features of the J-PET detector, the modular prototype and their applications for possible studies with positron and positronium beams are discussed. Preliminary results of the first test experiment performed on two detection units in the continuous positron beam recently developed at the Antimatter Laboratory (AML) of Trento are also reported.
△ Less
Submitted 7 January, 2023;
originally announced January 2023.
-
Realistic Total-Body J-PET Geometry Optimization -- Monte Carlo Study
Authors:
Jakub Baran,
Wojciech Krzemien,
Lech Raczyński,
Mateusz Bała,
Aurelien Coussat,
Szymon Parzych,
Neha Chug,
Eryk Czerwiński,
Catalina Oana Curceanu,
Meysam Dadgar,
Kamil Dulski,
Kavya Eliyan,
Jan Gajewski,
Aleksander Gajos,
Beatrix Hiesmayr,
Krzysztof Kacprzak,
Łukasz Kapłon,
Konrad Klimaszewski,
Grzegorz Korcyl,
Tomasz Kozik,
Deepak Kumar,
Szymon Niedźwiecki,
Dominik Panek,
Elena Perez del Rio,
Antoni Ruciński
, et al. (9 additional authors not shown)
Abstract:
Total-Body PET is one of the most promising medical diagnostics modalities. The high sensitivity provided by Total-Body technology can be advantageous for novel tomography methods like positronium imaging. Several efforts are ongoing to lower the price of the TB-PET systems. Among the alternatives, the Jagiellonian PET (J-PET) technology, based on plastic scintillator strips, offers a low-cost alt…
▽ More
Total-Body PET is one of the most promising medical diagnostics modalities. The high sensitivity provided by Total-Body technology can be advantageous for novel tomography methods like positronium imaging. Several efforts are ongoing to lower the price of the TB-PET systems. Among the alternatives, the Jagiellonian PET (J-PET) technology, based on plastic scintillator strips, offers a low-cost alternative. The work aimed to compare five Total-Body J-PET geometries as a possible next generation J-PET scanner design. We present comparative studies of performance characteristics of the cost-effective Total-Body PET scanners using J-PET technology. We investigated in silico five Total-Body scanner geometries. Monte Carlo simulations of the XCAT phantom, the 2-meter sensitivity line source and positronium sensitivity phantoms were performed. We compared the sensitivity profiles for 2-gamma and 3-gamma tomography, relative cost of the setups and performed quantitative analysis of the reconstructed images. The analysis of the reconstructed XCAT images reveals the superiority of the seven-ring scanners over the three-ring setups. However, the three-ring scanners would be approximately 2-3 times cheaper. The peak sensitivity values for two-gamma vary from 20 to 34 cps/kBq. The sensitivity curves for the positronium tomography have a similar shape to the two-gamma sensitivity profiles. The peak values are lower compared to the two-gamma cases, from about 20-28 times, with a maximum of 1.66 cps/kBq. The results show the feasibility of multi-organ imaging of all the systems to be considered for the next generation of TB J-PET designs. The relative cost for all the scanners is about 10-4 times lower compared to the cost of the uExplorer. These properties coupled together with J-PET cost-effectiveness, make the J-PET technology an attractive solution for broad application in clinics.
△ Less
Submitted 16 February, 2024; v1 submitted 5 December, 2022;
originally announced December 2022.
-
Direct tests of T, CP, CPT symmetries in transitions of neutral K mesons with the KLOE experiment
Authors:
D. Babusci,
M. Berłowski,
C. Bloise,
F. Bossi,
P. Branchini,
B. Cao,
F. Ceradini,
P. Ciambrone,
F. Curciarello,
E. Czerwiński,
G. D'Agostini,
R. D'Amico,
E. Danè,
V. De Leo,
E. De Lucia,
A. De Santis,
P. De Simone,
A. Di Domenico,
E. Diociaiuti,
D. Domenici,
A. D'Uffizi,
G. Fantini,
A. Gajos,
S. Gamrat,
P. Gauzzi
, et al. (18 additional authors not shown)
Abstract:
Tests of the T, CP and CPT symmetries in the neutral kaon system are performed by the direct comparison of the probabilities of a kaon transition process to its symmetry-conjugate. The exchange of in and out states required for a genuine test involving an anti-unitary transformation implied by time-reversal is implemented exploiting the entanglement of $K^0\bar{K}{}^0$ pairs produced at a $φ$-fact…
▽ More
Tests of the T, CP and CPT symmetries in the neutral kaon system are performed by the direct comparison of the probabilities of a kaon transition process to its symmetry-conjugate. The exchange of in and out states required for a genuine test involving an anti-unitary transformation implied by time-reversal is implemented exploiting the entanglement of $K^0\bar{K}{}^0$ pairs produced at a $φ$-factory. A data sample collected by the KLOE experiment at DA$Φ$NE corresponding to an integrated luminosity of about 1.7 fb$^{-1}$ is analysed to study the $Δ$t distributions of the $φ\to K_{S}K_{L}\to π^+π^- \: π^{\pm}e^{\mp}ν$ and $φ\to K_{S}K_{L}\to π^{\pm}e^{\mp}ν\: 3π^0$ processes, with $Δ$t the difference of the kaon decay times. A comparison of the measured $Δ$t distributions in the asymptotic region $Δt \gg τ_{S}$ allows to test for the first time T and CPT symmetries in kaon transitions with a precision of few percent, and to observe CP violation with this novel method.
△ Less
Submitted 19 December, 2022; v1 submitted 22 November, 2022;
originally announced November 2022.
-
First Simultaneous K$^-$p $\rightarrow (Σ^0/Λ) \, π^0$ Cross Sections Measurements at 98 MeV/c
Authors:
Kristian Piscicchia,
Magdalena Skurzok,
Michael Cargnelli,
Raffaele Del Grande,
Laura Fabbietti,
Johann Marton,
Pawel Moskal,
Alessandro Scordo,
Àngels Ramos,
Diana Laura Sirghi,
Oton Vazquez Doce,
Johann Zmeskal,
Slawomir Wycech,
Paolo Branchini,
Filippo Ceradini,
Eryk Czerwinski,
Erika De Lucia,
Salvatore Fiore,
Andrzej Kupsc,
Giuseppe Mandaglio,
Matteo Martini,
Antonio Passeri,
Vincenzo Patera,
Elena Perez Del Rio,
Andrea Selce
, et al. (2 additional authors not shown)
Abstract:
We report the first simultaneous and independent measurements of the K$^{-}$p $\rightarrow Σ^0 \, π^{0}$ and K$^{-}$p $\rightarrow Λ\, π^{0}$ cross sections around 100 MeV/c kaon momentum. The kaon beam delivered by the DA$Φ$NE collider was exploited to detect K$^-$ absorptions on Hydrogen atoms, populating the gas mixture of the KLOE drift chamber. The precision of the measurements (…
▽ More
We report the first simultaneous and independent measurements of the K$^{-}$p $\rightarrow Σ^0 \, π^{0}$ and K$^{-}$p $\rightarrow Λ\, π^{0}$ cross sections around 100 MeV/c kaon momentum. The kaon beam delivered by the DA$Φ$NE collider was exploited to detect K$^-$ absorptions on Hydrogen atoms, populating the gas mixture of the KLOE drift chamber. The precision of the measurements ($σ_{K^- p \rightarrow Σ^0 π^0} = 42.8 \pm 1.5 (stat.) ^{+2.4}_{-2.0}(syst.) \ \mathrm{mb}$ and $σ_{K^- p \rightarrow Λπ^0} = 31.0 \pm 0.5 (stat.) ^{+1.2}_{-1.2}(syst.) \ \mathrm{mb}\,$) is the highest yet obtained in the low kaon momentum regime.
△ Less
Submitted 20 October, 2022; v1 submitted 19 October, 2022;
originally announced October 2022.
-
Measurement of the $K_S \to πe ν$ branching fraction with the KLOE experiment
Authors:
D. Babusci,
M. Berlowski,
C. Bloise,
F. Bossi,
P. Branchini,
B. Cao,
F. Ceradini,
P. Ciambrone,
F. Curciarello,
E. Czerwiński,
G. D'Agostini,
R. D'Amico,
E. Danè,
V. De Leo,
E. De Lucia,
A. De Santis,
P. De Simone,
A. Di Cicco,
A. Di Domenico,
E. Diociaiuti,
D. Domenici,
A. D'Uffizi,
G. Fantini,
A. Gajos,
S. Gamrat
, et al. (18 additional authors not shown)
Abstract:
The branching fraction for the decay $K_S \to πe ν$ has been measured with a sample of 300 million $K_S$ mesons produced in $φ\to K_L K_S$ decays recorded by the KLOE experiment at the DA$Φ$NE $e^+e^-$ collider. Signal decays are selected by a boosted decision tree built with kinematic variables and time-of-flight measurements. Data control samples of $K_L \to πe ν$ decays are used to evaluate sig…
▽ More
The branching fraction for the decay $K_S \to πe ν$ has been measured with a sample of 300 million $K_S$ mesons produced in $φ\to K_L K_S$ decays recorded by the KLOE experiment at the DA$Φ$NE $e^+e^-$ collider. Signal decays are selected by a boosted decision tree built with kinematic variables and time-of-flight measurements. Data control samples of $K_L \to πe ν$ decays are used to evaluate signal selection efficiencies. A fit to the reconstructed electron mass distribution finds 49647$\pm$316 signal events. Normalising to the $K_S \to π^+π^-$ decay events the result for the branching fraction is $\mathcal{B}(K_S \to πe ν) = (7.211 \pm 0.046_{\rm stat} \pm 0.052_{\rm syst}) \times10^{-4}$. The combination with our previous measurement gives $\mathcal{B}(K_S \to πe ν) = (7.153 \pm 0.037_{\rm stat} \pm 0.043_{\rm syst}) \times10^{-4}$. From this value we derive $f_+(0)|V_{us}| = 0.2170 \pm 0.009$.
△ Less
Submitted 24 January, 2023; v1 submitted 9 August, 2022;
originally announced August 2022.
-
Positronium imaging with the novel multiphoton PET scanner
Authors:
Paweł Moskal,
Kamil Dulski,
Neha Chug,
Catalina Curceanu,
Eryk Czerwiński,
Meysam Dadgar,
Jan Gajewski,
Aleksander Gajos,
Grzegorz Grudzień,
Beatrix C. Hiesmayr,
Krzysztof Kacprzak,
Łukasz Kapłon,
Hanieh Karimi,
Konrad Klimaszewski,
Grzegorz Korcyl,
Paweł Kowalski,
Tomasz Kozik,
Nikodem Krawczyk,
Wojciech Krzemień,
Ewelina Kubicz,
Piotr Małczak,
Szymon Niedźwiecki,
Monika Pawlik-Niedźwiecka,
Michał Pędziwiatr,
Lech Raczyński
, et al. (11 additional authors not shown)
Abstract:
In vivo assessment of cancer and precise location of altered tissues at initial stages of molecular disorders are important diagnostic challenges. Positronium is copiously formed in the free molecular spaces in the patient's body during positron emission tomography (PET). The positronium properties vary according to the size of inter- and intramolecular voids and the concentration of molecules in…
▽ More
In vivo assessment of cancer and precise location of altered tissues at initial stages of molecular disorders are important diagnostic challenges. Positronium is copiously formed in the free molecular spaces in the patient's body during positron emission tomography (PET). The positronium properties vary according to the size of inter- and intramolecular voids and the concentration of molecules in them such as, e.g., molecular oxygen, O2; therefore, positronium imaging may provide information about disease progression during the initial stages of molecular alterations. Current PET systems do not allow acquisition of positronium images. This study presents a new method that enables positronium imaging by simultaneous registration of annihilation photons and deexcitation photons from pharmaceuticals labeled with radionuclides. The first positronium imaging of a phantom built from cardiac myxoma and adipose tissue is demonstrated. It is anticipated that positronium imaging will substantially enhance the specificity of PET diagnostics.
△ Less
Submitted 16 December, 2021;
originally announced December 2021.
-
Testing CPT symmetry in ortho-positronium decays with positronium annihilation tomography
Authors:
Paweł Moskal,
Aleksander Gajos,
Muhsin Mohammed,
Jyoti Chhokar,
Neha Chug,
Catalina Curceanu,
Eryk Czerwiński,
Meysam Dadgar,
Kamil Dulski,
Marek Gorgol,
Jacek Goworek,
Beatrix Hiesmayr,
Bożena Jasińska,
Krzysztof Kacprzak,
Łukasz Kapłon,
Hanieh Karimi,
Daria Kisielewska,
Konrad Klimaszewski,
Grzegorz Korcyl,
Paweł Kowalski,
Nikodem Krawczyk,
Wojciech Krzemień,
Tomasz Kozik,
Ewelina Kubicz,
Szymon Niedźwiecki
, et al. (13 additional authors not shown)
Abstract:
Charged lepton system symmetry under combined charge, parity, and time-reversal transformation (CPT) remains scarcely tested. Despite stringent quantum-electrodynamic limits, discrepancies in predictions for the electron-positron bound state (positronium atom) motivate further investigation, including fundamental symmetry tests. While CPT noninvariance effects could be manifested in non-vanishing…
▽ More
Charged lepton system symmetry under combined charge, parity, and time-reversal transformation (CPT) remains scarcely tested. Despite stringent quantum-electrodynamic limits, discrepancies in predictions for the electron-positron bound state (positronium atom) motivate further investigation, including fundamental symmetry tests. While CPT noninvariance effects could be manifested in non-vanishing angular correlations between final-state photons and spin of annihilating positronium, measurements were previously limited by knowledge of the latter. Here, we demonstrate tomographic reconstruction techniques applied to three-photon annihilations of ortho-positronium atoms to estimate their spin polarisation without magnetic field or polarised positronium source. We use a plastic-scintillator-based positron-emission-tomography scanner to record ortho-positronium (o-Ps) annihilations with single-event estimation of o-Ps spin and determine the complete spectrum of an angular correlation operator sensitive to CPT-violating effects. We find no violation at the precision level of 10^{-4}, with an over threefold improvement on the previous measurement.
△ Less
Submitted 8 December, 2021;
originally announced December 2021.
-
Precision tests of Quantum Mechanics and CPT symmetry with entangled neutral kaons at KLOE
Authors:
D. Babusci,
M. Berlowski,
C. Bloise,
F. Bossi,
P. Branchini,
A. Budano,
B. Cao,
F. Ceradini,
P. Ciambrone,
F. Curciarello,
E. Czerwiński,
G. D'Agostini,
R. D'Amico,
E. Danè,
V. De Leo,
E. De Lucia,
A. De Santis,
P. De Simone,
A. Di Cicco,
A. Di Domenico,
E. Diociaiuti,
D. Domenici,
A. D'Uffizi,
A. Fantini,
G. Fantini
, et al. (33 additional authors not shown)
Abstract:
The quantum interference between the decays of entangled neutral kaons is studied in the process $φ\rightarrow K_S K_L \rightarrowπ^+π^-π^+π^-$, which exhibits the characteristic Einstein--Podolsky--Rosen correlations that prevent both kaons to decay into $π^+π^-$ at the same time. This constitutes a very powerful tool for testing at the utmost precision the quantum coherence of the entangled kaon…
▽ More
The quantum interference between the decays of entangled neutral kaons is studied in the process $φ\rightarrow K_S K_L \rightarrowπ^+π^-π^+π^-$, which exhibits the characteristic Einstein--Podolsky--Rosen correlations that prevent both kaons to decay into $π^+π^-$ at the same time. This constitutes a very powerful tool for testing at the utmost precision the quantum coherence of the entangled kaon pair state, and to search for tiny decoherence and CPT violation effects, which may be justified in a quantum gravity framework. The analysed data sample was collected with the KLOE detector at DA$Φ$NE, the Frascati $φ$-factory, and corresponds to an integrated luminosity of about 1.7 fb$^{-1}$, i.e. to about $1.7 \times 10^9$ $φ\rightarrow K_S K_L$ decays produced. From the fit of the observed $Δt$ distribution, being $Δt$ the difference of the kaon decay times, the decoherence and CPT violation parameters of various phenomenological models are measured with a largely improved accuracy with respect to previous analyses. The results are consistent with no deviation from quantum mechanics and CPT symmetry, while for some parameters the precision reaches the interesting level at which -- in the most optimistic scenarios -- quantum gravity effects might show up. They provide the most stringent limits up to date on the considered models.
△ Less
Submitted 6 April, 2022; v1 submitted 8 November, 2021;
originally announced November 2021.
-
Optimisation of the event-based TOF filtered back-projection for online imaging in total-body J-PET
Authors:
R. Y. Shopa,
K. Klimaszewski,
P. Kopka,
P. Kowalski,
W. Krzemień,
L. Raczyński,
W. Wiślicki,
N. Chug,
C. Curceanu,
E. Czerwiński,
M. Dadgar,
K. Dulski,
A. Gajos,
B. C. Hiesmayr,
K. Kacprzak,
Ł. Kapłon,
D. Kisielewska,
G. Korcyl,
N. Krawczyk,
E. Kubicz,
Sz. Niedźwiecki,
J. Raj,
S. Sharma,
Shivani,
E. L. Stȩpień
, et al. (2 additional authors not shown)
Abstract:
We perform a parametric study of the newly developed time-of-flight (TOF) image reconstruction algorithm, proposed for the real-time imaging in total-body Jagiellonian PET (J-PET) scanners. The asymmetric 3D filtering kernel is applied at each most likely position of electron-positron annihilation, estimated from the emissions of back-to-back $γ$-photons. The optimisation of its parameters is stud…
▽ More
We perform a parametric study of the newly developed time-of-flight (TOF) image reconstruction algorithm, proposed for the real-time imaging in total-body Jagiellonian PET (J-PET) scanners. The asymmetric 3D filtering kernel is applied at each most likely position of electron-positron annihilation, estimated from the emissions of back-to-back $γ$-photons. The optimisation of its parameters is studied using Monte Carlo simulations of a 1-mm spherical source, NEMA IEC and XCAT phantoms inside the ideal J-PET scanner. The combination of high-pass filters which included the TOF filtered back-projection (FBP), resulted in spatial resolution, 1.5 $\times$ higher in the axial direction than for the conventional 3D FBP. For realistic $10$-minute scans of NEMA IEC and XCAT, which require a trade-off between the noise and spatial resolution, the need for Gaussian TOF kernel components, coupled with median post-filtering, is demonstrated. The best sets of 3D filter parameters were obtained by the Nelder-Mead minimisation of the mean squared error between the resulting and reference images. The approach allows training the reconstruction algorithm for custom scans, using the IEC phantom, when the temporal resolution is below 50 ps. The image quality parameters, estimated for the best outcomes, were systematically better than for the non-TOF FBP.
△ Less
Submitted 27 July, 2021;
originally announced July 2021.
-
Simulating NEMA characteristics of the modular total-body J-PET scanner -- an economic total-body PET from plastic scintillators
Authors:
Paweł Moskal,
Paweł Kowalski,
Roman Shopa,
Lech Raczyński,
Jakub Baran,
Neha Chug,
Catalina Curceanu,
Eryk Czerwiński,
Meysam Dadgar,
Kamil Dulski,
Aleksander Gajos,
Beatrix Hiesmayr,
Krzysztof Kacprzak,
Łukasz Kapłon,
Daria Kisielewska,
Konrad Klimaszewski,
Przemysław Kopka,
Gregorz Korcyl,
Nikodem Krawczyk,
Wojciech Krzemień,
Ewelina Kubicz,
Szymon Niedźwiecki,
Szymon Parzych,
Juhi Raj,
Sushil Sharma
, et al. (4 additional authors not shown)
Abstract:
The purpose of the presented research is estimation of the performance characteristics of the economic Total-Body Jagiellonian-PET system (TB-J-PET) constructed from plastic scintillators. The characteristics are estimated according to the NEMA NU-2-2018 standards utilizing the GATE package. The simulated detector consists of 24 modules, each built out of 32 plastic scintillator strips (each with…
▽ More
The purpose of the presented research is estimation of the performance characteristics of the economic Total-Body Jagiellonian-PET system (TB-J-PET) constructed from plastic scintillators. The characteristics are estimated according to the NEMA NU-2-2018 standards utilizing the GATE package. The simulated detector consists of 24 modules, each built out of 32 plastic scintillator strips (each with cross section of 6 mm times 30 mm and length of 140 cm or 200 cm) arranged in two layers in regular 24-sided polygon circumscribing a circle with the diameter of 78.6 cm. For the TB-J-PET with an axial field-of-view (AFOV) of 200 cm, a spatial resolutions of 3.7 mm (transversal) and 4.9 mm (axial) are achieved. The NECR peak of 630 kcps is expected at 30 kBq/cc activity concentration and the sensitivity at the center amounts to 38 cps/kBq. The SF is estimated to 36.2 %. The values of SF and spatial resolution are comparable to those obtained for the state-of-the-art clinical PET scanners and the first total-body tomographs: uExplorer and PennPET. With respect to the standard PET systems with AFOV in the range from 16 cm to 26 cm, the TB-J-PET is characterized by an increase in NECR approximately by factor of 4 and by the increase of the whole-body sensitivity by factor of 12.6 to 38. The TOF resolution for the TB-J-PET is expected to be at the level of CRT=240 ps (FWHM). For the TB-J-PET with an axial field-of-view (AFOV) of 140 cm, an image quality of the reconstructed images of a NEMA IEC phantom was presented with a contrast recovery coefficient (CRC) and a background variability parameters. The increase of the whole-body sensitivity and NECR estimated for the TB-J-PET with respect to current commercial PET systems makes the TB-J-PET a promising cost-effective solution for the broad clinical applications of total-body PET scanners.
△ Less
Submitted 3 July, 2021;
originally announced July 2021.
-
Synchronisation and calibration of the 24-modules J-PET prototype with 300~mm axial field of view
Authors:
P. Moskal,
T. Bednarski,
Sz. Niedzwiecki,
M. Silarski,
E. Czerwinski,
T. Kozik,
J. Chhokar,
M. Bała,
C. Curceanu,
R. Del Grande,
M. Dadgar,
K. Dulski,
A. Gajos,
M. Gorgol,
N. Gupta-Sharma,
B. C. Hiesmayr,
B. Jasinska,
K. Kacprzak,
L. Kaplon,
H. Karimi,
D. Kisielewska,
K. Klimaszewski,
G. Korcyl,
P. Kowalski,
N. Krawczyk
, et al. (14 additional authors not shown)
Abstract:
Research conducted in the framework of the J-PET project aims to develop a cost-effective total-body positron emission tomography scanner. As a first step on the way to construct a full-scale J-PET tomograph from long strips of plastic scintillators, a 24-strip prototype was built and tested. The prototype consists of detection modules arranged axially forming a cylindrical diagnostic chamber with…
▽ More
Research conducted in the framework of the J-PET project aims to develop a cost-effective total-body positron emission tomography scanner. As a first step on the way to construct a full-scale J-PET tomograph from long strips of plastic scintillators, a 24-strip prototype was built and tested. The prototype consists of detection modules arranged axially forming a cylindrical diagnostic chamber with the inner diameter of 360 mm and the axial field-of-view of 300 mm. Promising perspectives for a low-cost construction of a total-body PET scanner are opened due to an axial arrangement of strips of plastic scintillators, wchich have a small light attenuation, superior timing properties, and the possibility of cost-effective increase of the axial field-of-view. The presented prototype comprises dedicated solely digital front-end electronic circuits and a triggerless data acquisition system which required development of new calibration methods including time, thresholds and gain synchronization. The system and elaborated calibration methods including first results of the 24-module J-PET prototype are presented and discussed. The achieved coincidence resolving time equals to CRT = 490 $\pm$ 9 ps. This value can be translated to the position reconstruction accuracy $σ(Δl) =$ 18 mm which is fairly position-independent.
△ Less
Submitted 25 August, 2020;
originally announced August 2020.
-
Search for the $η$ mesic $^3$He in the $pd\rightarrow d p π^{0}$ reaction with the WASA-at-COSY facility
Authors:
P. Adlarson,
W. Augustyniak,
M. Bashkanov,
S. D. Bass,
F. S. Bergmann,
M. Berlowski,
A. Bondar,
M. Buscher,
H. Calen,
I. Ciepal,
H. Clement,
E. Czerwinski,
K. Demmich,
R. Engels,
A. Erven,
W. Erven,
W. Eyrich,
P. Fedorets,
K. Fohl,
K. Fransson,
F. Goldenbaum,
A. Goswami,
K. Grigoryev,
L. Heijkenskjold,
V. Hejny
, et al. (58 additional authors not shown)
Abstract:
The excitation function for the $pd\rightarrow$ $d p π^{0}$ reaction has been measured by WASA-at-COSY experiment with the aim of searching for $^{3}\hspace{-0.03cm}\mbox{He}$-$η$ mesic nuclei. The measurement in the vicinity of $η$ meson production was performed using a ramped proton beam. The data analysis and interpretation was carried out with the assumption that the $η$-mesic Helium decays vi…
▽ More
The excitation function for the $pd\rightarrow$ $d p π^{0}$ reaction has been measured by WASA-at-COSY experiment with the aim of searching for $^{3}\hspace{-0.03cm}\mbox{He}$-$η$ mesic nuclei. The measurement in the vicinity of $η$ meson production was performed using a ramped proton beam. The data analysis and interpretation was carried out with the assumption that the $η$-mesic Helium decays via the formation of an intermediate N$^{*}$(1535) resonance. No direct signal of the $η$-mesic nucleus is observed in the excitation function. We determine a new improved upper limit for the total cross section for the bound state production and decay in the $pd\rightarrow$ $(^{3}\hspace{-0.03cm}\mbox{He}$-$η)_{bound} \rightarrow$ $d p π^{0}$ process. It varies between 13 nb to 24 nb for the bound state with width in the range $Γ\in (5,50)$ MeV.
△ Less
Submitted 26 September, 2020; v1 submitted 30 July, 2020;
originally announced July 2020.
-
Upper limit on the $η\toπ^{+}π^{-}$ branching fraction with the KLOE experiment
Authors:
D. Babusci,
M. Berlowski,
C. Bloise,
F. Bossi,
P. Branchini,
A. Budano,
B. Cao,
F. Ceradini,
P. Ciambrone,
F. Curciarello,
E. Czerwiński,
G. D'Agostini,
E. Danè,
V. De Leo,
E. De Lucia,
A. De Santis,
P. De Simone,
A. Di Cicco,
A. Di Domenico,
D. Domenici,
A. D'Uffizi,
A. Fantini,
P. Fermani,
S. Fiore,
A. Gajos
, et al. (31 additional authors not shown)
Abstract:
Based on an integrated luminosity of 1.61 fb$^{-1}$ $e^+e^-$ collision data collected with the KLOE detector at DA$Φ$NE, the Frascati $φ$-factory, a search for the $P$- and $CP$-violating decay $η\toπ^{+}π^{-}$ has been performed. Radiative $φ\toηγ$ decay is exploited to access the $η$ mesons. No signal is observed in the $π^{+}π^{-}$ invariant mass spectrum, and the upper limit on the branching f…
▽ More
Based on an integrated luminosity of 1.61 fb$^{-1}$ $e^+e^-$ collision data collected with the KLOE detector at DA$Φ$NE, the Frascati $φ$-factory, a search for the $P$- and $CP$-violating decay $η\toπ^{+}π^{-}$ has been performed. Radiative $φ\toηγ$ decay is exploited to access the $η$ mesons. No signal is observed in the $π^{+}π^{-}$ invariant mass spectrum, and the upper limit on the branching fraction at 90\% confidence level is determined to be ${\mathcal B}(η\toπ^{+}π^{-})<4.9\times10^{-6}$, which is approximately three times smaller than the previous KLOE result. From the combination of these two measurements we get ${\mathcal B}(η\toπ^{+}π^{-}) < 4.4\times10^{-6}$ at 90\% confidence level.
△ Less
Submitted 28 February, 2021; v1 submitted 25 June, 2020;
originally announced June 2020.
-
The J-PET detector -- a tool for precision studies of ortho-positronium decays
Authors:
K. Dulski,
S. D. Bass,
J. Chhokar,
N. Chug,
C. Curceanu,
E. Czerwiński,
M. Dadgar,
J. Gajewski,
A. Gajos,
M. Gorgol,
R. Del Grande,
B. C. Hiesmayr,
B. Jasińska,
K. Kacprzak,
Ł. Kapłon,
H. Karimi,
D. Kisielewska,
K. Klimaszewski,
P. Kopka,
G. Korcyl,
P. Kowalski,
T. Kozik,
N. Krawczyk,
W. Krzemień,
E. Kubicz
, et al. (19 additional authors not shown)
Abstract:
The J-PET tomograph is constructed from plastic scintillator strips arranged axially in concentric cylindrical layers. It enables investigations of positronium decays by measurement of the time, position, polarization and energy deposited by photons in the scintillators, in contrast to studies conducted so far with crystal and semiconductor based detection systems where the key selection of events…
▽ More
The J-PET tomograph is constructed from plastic scintillator strips arranged axially in concentric cylindrical layers. It enables investigations of positronium decays by measurement of the time, position, polarization and energy deposited by photons in the scintillators, in contrast to studies conducted so far with crystal and semiconductor based detection systems where the key selection of events is based on the measurement of the photons energies. In this article we show that the J-PET tomograph system is capable of exclusive measurements of the decays of ortho-positronium atoms. We present the first positronium production results, its lifetime distribution measurements and discuss estimation of the influence of various background sources. The tomograph s performance demonstrated here makes it suitable for precision studies of positronium decays including entanglement of the final state photons, positron annihilation lifetime spectroscopy plus molecular imaging diagnostics.
△ Less
Submitted 25 May, 2021; v1 submitted 9 June, 2020;
originally announced June 2020.
-
Hit-time and hit-position reconstruction in strips of plastic scintillators using multi-threshold readouts
Authors:
N. G. Sharma,
M. Silarski,
J. Chhokar,
E. Czerwinski,
C. Curceanu,
K. Dulski,
K. Farbaniec,
A. Gajos,
R. Del Grande,
M. Gorgol,
B. C. Hiesmayr,
B. Jasinska,
K. Kacprzak,
L. Kaplon,
D. Kisielewska,
K. Klimaszewski,
G. Korcyl,
P. Kowalski,
N. Krawczyk,
W. Krzemien,
T. Kozik,
E. Kubicz,
M. Mohammed,
Sz. Niedzwiecki,
M. Palka
, et al. (10 additional authors not shown)
Abstract:
In this article, a new method for the reconstruction of hit-position and hit-time of photons in long scintillator detectors is investigated. This research is motivated by the recent development of the positron emission tomography scanners based on plastic scintillators. The proposed method constitutes a new way of signal processing in Multi-Voltage-Technique. It is based on the determination of th…
▽ More
In this article, a new method for the reconstruction of hit-position and hit-time of photons in long scintillator detectors is investigated. This research is motivated by the recent development of the positron emission tomography scanners based on plastic scintillators. The proposed method constitutes a new way of signal processing in Multi-Voltage-Technique. It is based on the determination of the degree of similarity between the registered signals and the synchronized model signals stored in a library. The library was established for a set of well defined hit-positions along the length of the scintillator. The Mahalanobis distance was used as a measure of similarity between the two compared signals. The method was validated on the experimental data measured using two-strips J-PET prototype with dimensions of 5x9x300 mm$^3$. The obtained Time-of-Flight (TOF) and spatial resolutions amount to 325~ps (FWHM) and 25~mm (FWHM), respectively. The TOF resolution was also compared to the results of an analogous study done using Linear Fitting method. The best TOF resolution was obtained with this method at four pre-defined threshold levels which was comparable to the resolution achieved from the Mahalanobis distance at two pre-defined threshold levels. Although the algorithm of Linear Fitting method is much simpler to apply than the Mahalanobis method, the application of the Mahalanobis distance requires a lower number of applied threshold levels and, hence, decreases the costs of electronics used in PET scanner.
△ Less
Submitted 27 April, 2020;
originally announced April 2020.
-
Differential Cross Sections for Neutron-Proton Scattering in the Region of the $d^*(2380)$ Dibaryon Resonance
Authors:
P. Adlarson,
W. Augustyniak,
W. Bardan,
M. Bashkanov,
F. S. Bergmann,
M. Berłowski,
H. Bhatt,
M. Büscher,
H. Calén,
I. Ciepał,
H. Clement,
D. Coderre,
E. Czerwiński,
K. Demmich,
E. Doroshkevich,
R. Engels,
A. Erven,
W. Erven,
W. Eyrich,
P. Fedorets,
K. Föhl,
K. Fransson,
F. Goldenbaum,
P. Goslawski,
A. Goswami
, et al. (80 additional authors not shown)
Abstract:
Differential cross sections have been extracted from exclusive and kinematically complete high-statistics measurements of quasifree polarized $\vec{n}p$ scattering performed in the energy region of the $d^*(2380)$ dibaryon resonance covering the the range of beam energies $T_n$ = 0.98 - 1.29 GeV ($\sqrt s$ = 2.32 - 2.44 GeV). The experiment was carried out with the WASA-at-COSY setup having a pola…
▽ More
Differential cross sections have been extracted from exclusive and kinematically complete high-statistics measurements of quasifree polarized $\vec{n}p$ scattering performed in the energy region of the $d^*(2380)$ dibaryon resonance covering the the range of beam energies $T_n$ = 0.98 - 1.29 GeV ($\sqrt s$ = 2.32 - 2.44 GeV). The experiment was carried out with the WASA-at-COSY setup having a polarized deuteron beam im**ed on the hydrogen pellet target and utilizing the quasifree process $dp \to np + p_{spectator}$. That way the $np$ differential cross section $σ(Θ)$ was measured over a large angular range. The obtained angular distributions complement the corresponding analyzing power $A_y(Θ)$ measurements published previously. A SAID partial-wave analysis incorporating the new data strengthens the finding of a resonance pole in the coupled $^3D_3 - ^3G_3$ waves.
△ Less
Submitted 29 March, 2020;
originally announced March 2020.
-
Towards Time Reversal Symmetry Test with o-Ps Decays using the J-PET detector
Authors:
Juhi Raj,
Kamil Dilski,
Eryk Czerwinski
Abstract:
One of the features of the triplet state of positronium (ortho-Positronium)atoms is its relatively longer lifetime when compared to the singlet states ofpositronium (para-Positronium) atoms. The most probable decay of ortho-Positronium is into three annihilation photons. In order to test the discretesymmetry using the time-reversal symmetry odd-operator, it is importantto identify ortho-Positroniu…
▽ More
One of the features of the triplet state of positronium (ortho-Positronium)atoms is its relatively longer lifetime when compared to the singlet states ofpositronium (para-Positronium) atoms. The most probable decay of ortho-Positronium is into three annihilation photons. In order to test the discretesymmetry using the time-reversal symmetry odd-operator, it is importantto identify ortho-Positronium decay. Identification of the decay of ortho-Positronium atoms by measuring the positronium annihilation lifetime withthe Jagiellonian-Positron Emission Tomograph (J-PET) is presented in this article.
△ Less
Submitted 3 December, 2019;
originally announced December 2019.
-
Estimating relationship between the Time Over Threshold and energy loss by photons in plastic scintillators used in the J-PET scanner
Authors:
S. Sharma,
J. Chhokar,
C. Curceanu,
E. Czerwinski,
M. Dadgar,
K. Dulski,
J. Gajewski,
A. Gajos,
M. Gorgol,
N. Gupta-Sharma,
R. Del Grande,
B. C. Hiesmayr,
B. Jasinska,
K. Kacprzak,
L. Kaplon,
H. Karimi,
D. Kisielewska,
K. Klimaszewski,
G. Korcyl,
P. Kowalski,
T. Kozik,
N. Krawczyk,
W. Krzemien,
E. Kubicz,
M. Mohammed
, et al. (14 additional authors not shown)
Abstract:
Time-Over-Threshold (TOT) technique is being used widely due to its implications in develo** the multi channel readouts mainly when fast signal processing is required. Using TOT technique as a measure of energy loss instead of charge integration methods significantly reduces the signals readout cost by combining the time and energy information. Therefore, this approach can potentially be used in…
▽ More
Time-Over-Threshold (TOT) technique is being used widely due to its implications in develo** the multi channel readouts mainly when fast signal processing is required. Using TOT technique as a measure of energy loss instead of charge integration methods significantly reduces the signals readout cost by combining the time and energy information. Therefore, this approach can potentially be used in J-PET tomograph which is build from plastic scintillators characterized by fast light signals. The drawback in adopting this technique is lying in the non-linear correlation between input energy loss and TOT of the signal. The main motivation behind this work is to develop the relationship between TOT and energy loss and validate it with the J-PET tomograph.
The experiment was performed using the $^{22}$Na beta emitter source placed in the center of the J-PET tomograph. One can obtain primary photons of two different energies: 511 keV photon from the annihilation of positron (direct annihilation or through the formation of para-Positronim atom or pick-off process of ortho-Positronium atoms), and 1275 keV prompt photon. This allows to study the correlation between TOT values and energy loss for energy range up to 1000 keV. As the photon interacts dominantly via Compton scattering inside the plastic scintillator, there is no direct information of primary photon energy. However, using the J-PET geometry one can measure the scattering angle of the interacting photon. Since, $^{22}$Na source emits photons of two different energies, it is required to know unambiguously the energy of incident photons and its corresponding scattering angle for the estimation of energy deposition. In this work, the relationship between Time Over Threshold and energy loss by interacting photons inside the plastic scintillators used in J-PET scanner is established for a energy deposited range 100-1000 keV
△ Less
Submitted 27 November, 2019;
originally announced November 2019.
-
Performance assessment of the 2$γ$ positronium imaging with the total-body PET scanners
Authors:
P. Moskal,
D. Kisielewska,
Z. Bura,
C. Chhokar,
C. Curceanu,
E. Czerwiński,
M. Dadgar 1,
K. Dulski,
J. Gajewski,
A. Gajos,
M. Gorgol,
R. Del Grande,
B. C. Hiesmayr,
B. Jasińska,
K. Kacprzak,
A. Kamińska,
Ł. Kapłon,
H. Karimi,
G. Korcyl,
P. Kowalski,
N. Krawczyk,
W. Krzemień,
T. Kozik,
E. Kubicz,
P. Małczak
, et al. (17 additional authors not shown)
Abstract:
In living organisms the positron-electron annihilation (occurring during the PET imaging) proceeds in about 30% via creation of a metastable ortho-positronium atom. In the tissue, due to the pick-off and conversion processes, over 98% of ortho-positronia annihilate into two 511~keV photons. In this article we assess the feasibility for reconstruction of the mean ortho-positronium lifetime image ba…
▽ More
In living organisms the positron-electron annihilation (occurring during the PET imaging) proceeds in about 30% via creation of a metastable ortho-positronium atom. In the tissue, due to the pick-off and conversion processes, over 98% of ortho-positronia annihilate into two 511~keV photons. In this article we assess the feasibility for reconstruction of the mean ortho-positronium lifetime image based on annihilations into two photons. The main objectives of this work include: (i) estimation of the sensitivity of the total-body PET scanners for the ortho-positronium mean lifetime imaging using $2γ$ annihilations, and (ii) estimation of the spatial and time resolution of the ortho-positronium image as a function of the coincidence resolving time (CRT) of the scanner. Simulations are conducted assuming that radiopharmaceutical is labelled with $^{44}Sc$ isotope emitting one positron and one prompt gamma. The image is reconstructed on the basis of triple coincidence events. The ortho-positronium lifetime spectrum is determined for each voxel of the image. Calculations were performed for cases of total-body detectors build of (i) LYSO scintillators as used in the EXPLORER PET, and (ii) plastic scintillators as anticipated for the cost-effective total-body J-PET scanner. To assess the spatial and time resolution the three cases were considered assuming that CRT is equal to 140ps, 50ps and 10ps. The estimated total-body PET sensitivity for the registration and selection of image forming triple coincidences is larger by a factor of 12.2 (for LYSO PET) and by factor of 4.7 (for plastic PET) with respect to the sensitivity for the standard $2γ$ imaging by LYSO PET scanners with AFOV=20cm.
△ Less
Submitted 15 November, 2019;
originally announced November 2019.
-
Study of Three-Nucleon Dynamics in the dp breakup collisions using the WASA detector
Authors:
P. Adlarson,
W. Augustyniak,
W. Bardan,
M. Bashkanov,
F. S. Bergmann,
M. Berlowski,
A. Bondar,
M. Buscher,
H. Calen,
I. Ciepal,
H. Clement,
E. Czerwinski,
K. Demmich,
R. Engels,
A. Erven,
W. Erven,
W. Eyrich,
P. Fedorets,
K. Fohl,
K. Fransson,
F. Goldenbaum,
A. Goswami,
K. Grigoryev,
L. Heijkenskjold,
V. Hejny
, et al. (64 additional authors not shown)
Abstract:
Differential cross section for the 1H(d,pp)n breakup reaction at deuteron beam energy of 340 MeV has been measured with the use of WASA detector at COSY-Juelich. The set of proton-proton coincidences registered at Forward Detector has been analysed on dense grid of kinematic variables, giving in total around 5600 data points. The cross section data are compared to theoretical predictions based on…
▽ More
Differential cross section for the 1H(d,pp)n breakup reaction at deuteron beam energy of 340 MeV has been measured with the use of WASA detector at COSY-Juelich. The set of proton-proton coincidences registered at Forward Detector has been analysed on dense grid of kinematic variables, giving in total around 5600 data points. The cross section data are compared to theoretical predictions based on the state-of-the-art nucleon-nucleon potentials, combined with three-nucleon force, Coulomb interaction or carried out in a relativistic regime.
△ Less
Submitted 14 November, 2019;
originally announced November 2019.
-
Search for eta mesic 3He with the WASA-at-COSY facility in the pd-> 3He 2gamma and pd-> 3He 6gamma reactions
Authors:
P. Adlarson,
W. Augustyniak,
W. Bardan,
M. Bashkanov,
S. D. Bass,
M. Berłowski,
A. Bondar,
M. Büscher,
H. Calén,
I. Ciepał,
H. Clement,
E. Czerwiński,
R. Engels,
A. Erven,
W. Erven,
W. Eyrich,
P. Fedorets,
K. Föhl,
K. Fransson,
F. Goldenbaum,
A. Goswami,
K. Grigoryev,
L. Heijkenskjöld,
V. Hejny,
S. Hirenzaki
, et al. (59 additional authors not shown)
Abstract:
We report on the experimental search for the bound state of an $η$ meson and $^{3}\hspace{-0.03cm}\mbox{He}$ nucleus performed using the WASA-at-COSY detector setup. In order to search for the $η$-mesic nucleus decay, the $pd\rightarrow$ $^{3}\hspace{-0.03cm}\mbox{He} 2γ$ and $pd\rightarrow$ $^{3}\hspace{-0.03cm}\mbox{He} 6γ$ channels have been analysed. These reactions manifest the direct decay o…
▽ More
We report on the experimental search for the bound state of an $η$ meson and $^{3}\hspace{-0.03cm}\mbox{He}$ nucleus performed using the WASA-at-COSY detector setup. In order to search for the $η$-mesic nucleus decay, the $pd\rightarrow$ $^{3}\hspace{-0.03cm}\mbox{He} 2γ$ and $pd\rightarrow$ $^{3}\hspace{-0.03cm}\mbox{He} 6γ$ channels have been analysed. These reactions manifest the direct decay of $η$ meson bound in $^{3}\hspace{-0.03cm}\mbox{He}$ nucleus. This non-mesonic decay channel has been considered for the first time. When taking into account only statistical errors, the obtained excitation functions reveal a slight indication for a possible bound state signal corresponding to an $^3$He-$η$ nucleus width $Γ$ above 20 MeV and binding energy $B_s$ between 0 and 15 MeV. However, the determined cross sections are consistent with zero in the range of the systematic uncertainty. Therefore, as final result we estimate only the upper limit for the cross section of the $η$-mesic $^{3}\hspace{-0.03cm}\mbox{He}$ nucleus formation followed by the $η$ meson decay which varies between $2$ nb and $15$ nb depending on possible bound state parameters.
△ Less
Submitted 7 January, 2020; v1 submitted 24 September, 2019;
originally announced September 2019.
-
Simulation studies of annihilation-photon's polarisation via Compton scattering with the J-PET tomograph
Authors:
N. Krawczyk,
B. C. Hiesmayr,
C. Curceanu,
E. Czerwiński,
K. Dulski,
A. Gajos,
M. Gorgol,
N. Gupta-Sharma,
B. Jasińska,
K. Kacprzak,
Ł. Kapłon,
D. Kisielewska,
K. Klimaszewski,
G. Korcyl,
P. Kowalski,
T. Kozik,
N. Krawczyk,
W. Krzemień,
E. Kubicz,
M. Mohammed,
Sz. Niedźwiecki,
M. Pałka,
M. Pawlik-Niedźwiecka,
L. Raczyński,
J. Raj
, et al. (10 additional authors not shown)
Abstract:
J-PET is the first positron-emission tomograph (PET) constructed from plastic scintillators. It was optimized for the detection of photons from electron-positron annihilation. Such photons, having an energy of 511 keV, interact with electrons in plastic scintillators predominantly via the Compton effect. Compton scattering is at most probable at an angle orthogonal to the electric field vector of…
▽ More
J-PET is the first positron-emission tomograph (PET) constructed from plastic scintillators. It was optimized for the detection of photons from electron-positron annihilation. Such photons, having an energy of 511 keV, interact with electrons in plastic scintillators predominantly via the Compton effect. Compton scattering is at most probable at an angle orthogonal to the electric field vector of the interacting photon. Thus registration of multiple photon scatterings with J-PET enables to determine the polarization of the annihilation photons. In this contribution we present estimates on the physical limitation in the accuracy of the polarization determination of $511$~keV photons with the J-PET detector.
△ Less
Submitted 18 January, 2019;
originally announced January 2019.
-
Feasibility studies of the polarization of photons beyond the optical wavelength regime with the J-PET detector
Authors:
P. Moskal,
N. Krawczyk,
B. C. Hiesmayr,
M. Bała,
C. Curceanu,
E. Czerwiński,
K. Dulski,
A. Gajos,
M. Gorgol,
R. Del Grande,
B. Jasińska,
K. Kacprzak,
L. Kapłon,
D. Kisielewska,
K. Klimaszewski,
G. Korcyl,
P. Kowalski,
T. Kozik,
W. Krzemień,
E. Kubicz,
M. Mohammed,
Sz. Niedźwiecki,
M. Pałka,
J. Raj,
Z. Rudy
, et al. (9 additional authors not shown)
Abstract:
J-PET is a detector optimized for registration of photons from the electron-positron annihilation via plastic scintillators where photons interact predominantly via Compton scattering. Registration of both primary and scattered photons enables to determinate the linear polarization of the primary photon on the event by event basis with a certain probability. Here we present quantitative results on…
▽ More
J-PET is a detector optimized for registration of photons from the electron-positron annihilation via plastic scintillators where photons interact predominantly via Compton scattering. Registration of both primary and scattered photons enables to determinate the linear polarization of the primary photon on the event by event basis with a certain probability. Here we present quantitative results on the feasibility of such polarization measurements of photons from the decay of positronium with the J-PET and explore the physical limitations for the resolution of the polarization determination of 511 keV photons via Compton scattering. For scattering angles of about 82 deg (where the best contrast for polarization measurement is theoretically predicted) we find that the single event resolution for the determination of the polarization is about 40 deg (predominantly due to properties of the Compton effect). However, for samples larger than ten thousand events the J-PET is capable of determining relative average polarization of these photons with the precision of about few degrees. The obtained results open new perspectives for studies of various physics phenomena such as quantum entanglement and tests of discrete symmetries in decays of positronium and extend the energy range of polarization measurements by five orders of magnitude beyond the optical wavelength regime.
△ Less
Submitted 27 September, 2018;
originally announced September 2018.
-
K$^-$ multi-nucleon absorption cross sections and branching ratios in $Λ$p and $Σ^0$p final states
Authors:
R. Del Grande,
K. Piscicchia,
O. Vazquez Doce,
M. Cargnelli,
C. Curceanu,
L. Fabbietti,
J. Marton,
P. Moskal,
A. Ramos,
A. Scordo,
D. Sirghi,
M. Skurzok,
S. Wycech,
J. Zmeskal,
E. Czerwinski,
V. De Leo,
P. Fermani,
G. Mandaglio,
M. Martini,
N. Raha,
A. Selce,
M. Silarski
Abstract:
The determination of low-energy cross sections and branching ratios of the K$^-$ multi-nucleon absorption processes in $Λ$p and $Σ^0$p final states performed by the AMADEUS collaboration is presented. Low momentum K$^-$ ($p_\mathrm{K} \simeq$ 127 MeV/c) produced at the DA$Φ$NE collider are im**ed on a Carbon target within the KLOE detector and the two and three nucleon absorption processes are d…
▽ More
The determination of low-energy cross sections and branching ratios of the K$^-$ multi-nucleon absorption processes in $Λ$p and $Σ^0$p final states performed by the AMADEUS collaboration is presented. Low momentum K$^-$ ($p_\mathrm{K} \simeq$ 127 MeV/c) produced at the DA$Φ$NE collider are im**ed on a Carbon target within the KLOE detector and the two and three nucleon absorption processes are disentangled by comparing the experimental data to phenomenological calculations. The $Λ$p spectra are interpreted in terms of K$^-$ multi-nucleon absorption processes; the possible contribution of a K$^-$pp bound state is demonstrated to overlap with the two nucleon capture process, its absolute yield thus resulting indistinguishable.
△ Less
Submitted 12 March, 2019; v1 submitted 19 September, 2018;
originally announced September 2018.
-
Commissioning of the J-PET detector in view of the positron annihilation lifetime spectroscopy
Authors:
K. Dulski,
C. Curceanu,
E. Czerwiński,
A. Gajos,
M. Gorgol,
N. Gupta-Sharma,
B. C. Hiesmayr,
B. Jasińska,
K. Kacprzak Ł. Kapłon,
D. Kisielewska,
K. Klimaszewski,
G. Korcyl,
P. Kowalski,
N. Krawczyk,
W. Krzemień,
T. Kozik,
E. Kubicz,
M. Mohammed,
Sz. Niedźwiecki,
M. Pałka,
M. Pawlik-Niedźwiecka,
L. Raczyński,
J. Raj,
K. Rakoczy,
Z. Rudy
, et al. (8 additional authors not shown)
Abstract:
The Jagiellonian Positron Emission Tomograph (J-PET) is the first PET device built from plastic scintillators. It is a multi-purpose detector designed for medical imaging and for studies of properties of positronium atoms in porous matter and in living organisms. In this article we report on the commissioning of the J-PET detector in view of studies of positronium decays. We present results of ana…
▽ More
The Jagiellonian Positron Emission Tomograph (J-PET) is the first PET device built from plastic scintillators. It is a multi-purpose detector designed for medical imaging and for studies of properties of positronium atoms in porous matter and in living organisms. In this article we report on the commissioning of the J-PET detector in view of studies of positronium decays. We present results of analysis of the positron lifetime measured in the porous polymer. The obtained results prove that J-PET is capable of performing simultaneous imaging of the density distribution of annihilation points as well as positron annihilation lifetime spectroscopy.
△ Less
Submitted 12 September, 2018;
originally announced September 2018.
-
A feasibility study of the time reversal violation test based on polarization of annihilation photons from the decay of ortho-Positronium with the J-PET detector
Authors:
J. Raj,
A. Gajos,
C. Curceanu,
E. Czerwinski,
K. Dulski,
M. Gorgol,
N. Gupta-Sharma,
B. C. Hiesmayr,
B. Jasińska,
K. Kacprzak,
L. Kaplon,
D. Kisielewska,
K. Klimaszewski,
G. Korcyl,
P. Kowalski,
T. Kozik,
N. Krawczyk,
W. Krzemien,
E. Kubicz,
M. Mohammed,
Sz. Niedzwiecki,
M. Palka,
M. Pawlik-Niedzwiecka,
L. Raczynski,
K. Rakoczy
, et al. (9 additional authors not shown)
Abstract:
The Jagiellonian Positron Emission Tomograph (J-PET) is a novel de- vice being developed at Jagiellonian University in Krakow, Poland based on or- ganic scintillators. J-PET is an axially symmetric and high acceptance scanner that can be used as a multi-purpose detector system. It is well suited to pur- sue tests of discrete symmetries in decays of positronium in addition to medical imaging. J-PET…
▽ More
The Jagiellonian Positron Emission Tomograph (J-PET) is a novel de- vice being developed at Jagiellonian University in Krakow, Poland based on or- ganic scintillators. J-PET is an axially symmetric and high acceptance scanner that can be used as a multi-purpose detector system. It is well suited to pur- sue tests of discrete symmetries in decays of positronium in addition to medical imaging. J-PET enables the measurement of both momenta and the polarization vectors of annihilation photons. The latter is a unique feature of the J-PET detector which allows the study of time reversal symmetry violation operator which can be constructed solely from the annihilation photons momenta before and after the scattering in the detector.
△ Less
Submitted 4 September, 2018;
originally announced September 2018.
-
Estimating the NEMA characteristics of the J-PET tomograph using the GATE package
Authors:
Paweł Kowalski,
Wojciech Wiślicki,
Roman Shopa,
Lech Raczyński,
Konrad Klimaszewski,
Catalina Curceanu,
Eryk Czerwiński,
Kamil Dulski,
Aleksander Gajos,
Marek Gorgol,
Neha Gupta-Sharma,
Beatrix Hiesmayr,
Bożena Jasińska,
Łukasz Kapłon,
Daria Kamińska,
Grzegorz Korcyl,
Tomasz Kozik,
Wojciech Krzemień,
Ewelina Kubicz,
Muhsin Mohammed,
Szymon Niedzwiecki,
Marek Pałka,
Monika Pawlik-Niedźwiecka,
Juhi Raj,
Kamil Rakoczy
, et al. (8 additional authors not shown)
Abstract:
The novel whole-body PET system based on plastic scintillators is developed by the {J-PET} Collaboration. It consists of plastic scintillator strips arranged axially in the form of a cylinder, allowing the cost-effective construction of the total-body PET. In order to determine properties of the scanner prototype and optimize its geometry, advanced computer simulations using the GATE software were…
▽ More
The novel whole-body PET system based on plastic scintillators is developed by the {J-PET} Collaboration. It consists of plastic scintillator strips arranged axially in the form of a cylinder, allowing the cost-effective construction of the total-body PET. In order to determine properties of the scanner prototype and optimize its geometry, advanced computer simulations using the GATE software were performed.
The spatial resolution, the sensitivity, the scatter fraction and the noise equivalent count rate were estimated according to the NEMA norm as a function of the length of the tomograph, number of the detection layers, diameter of the tomographic chamber and for various types of the applied readout. For the single-layer geometry with the diameter of 85 cm, strip length of 100 cm, cross-section of 4 mm x 20 mm and silicon photomultipliers with the additional layer of wavelength shifter as the readout, the spatial resolution (FWHM) in the centre of the scanner is equal to 3 mm (radial, tangential) and 6 mm (axial). For the analogous double-layer geometry with the same readout, diameter and scintillator length, with the strip cross-section of 7 mm x 20 mm, the NECR peak of 300 kcps was reached at 40 kBq/cc activity concentration, the scatter fraction is estimated to about 35% and the sensitivity at the centre amounts to 14.9 cps/kBq. Sensitivity profiles were also determined.
△ Less
Submitted 1 August, 2018;
originally announced August 2018.
-
Evaluation of Single-Chip, Real-Time Tomographic Data Processing on FPGA - SoC Devices
Authors:
G. Korcyl,
P. Białas,
C. Curceanu,
E. Czerwiński,
K. Dulski,
B. Flak,
A. Gajos,
B. Głowacz,
M. Gorgol,
B. C. Hiesmayr,
B. Jasińska,
K. Kacprzak,
M. Kajetanowicz,
D. Kisielewska,
P. Kowalski,
T. Kozik,
N. Krawczyk,
W. Krzemień,
E. Kubicz,
M. Mohammed,
Sz. Niedźwiecki,
M. Pawlik-Niedźwiecka,
M. Pałka,
L. Raczyński,
P. Rajda
, et al. (14 additional authors not shown)
Abstract:
A novel approach to tomographic data processing has been developed and evaluated using the Jagiellonian PET (J-PET) scanner as an example. We propose a system in which there is no need for powerful, local to the scanner processing facility, capable to reconstruct images on the fly. Instead we introduce a Field Programmable Gate Array (FPGA) System-on-Chip (SoC) platform connected directly to data…
▽ More
A novel approach to tomographic data processing has been developed and evaluated using the Jagiellonian PET (J-PET) scanner as an example. We propose a system in which there is no need for powerful, local to the scanner processing facility, capable to reconstruct images on the fly. Instead we introduce a Field Programmable Gate Array (FPGA) System-on-Chip (SoC) platform connected directly to data streams coming from the scanner, which can perform event building, filtering, coincidence search and Region-Of-Response (ROR) reconstruction by the programmable logic and visualization by the integrated processors. The platform significantly reduces data volume converting raw data to a list-mode representation, while generating visualization on the fly.
△ Less
Submitted 26 July, 2018;
originally announced July 2018.
-
Combined limit on the production of a light gauge boson decaying into $μ^+μ^-$ and $π^+π^-$
Authors:
KLOE-2 Collaboration,
:,
A. Anastasi,
D. Babusci,
M. Berlowski,
C. Bloise,
F. Bossi,
P. Branchini,
A. Budano,
B. Cao,
F. Ceradini,
P. Ciambrone,
F. Curciarello,
E. Czerwiński,
G. D'Agostinio,
E. Dané,
V. De Leo,
E. De Lucia,
A. De Santis,
P. De Simone,
A. Di Cicco,
A. Di Domenico,
D. Domenici,
A. D'Uffizi,
A. Fantini
, et al. (35 additional authors not shown)
Abstract:
We searched for the $μ^+μ^-$ decay of a light vector gauge boson, also known as dark photon, in the $e^+ e^- \to μ^+ μ^- γ_{\rm ISR}$ process by means of the Initial State Radiation (ISR) method. We used 1.93~fb$^{-1}$ of data collected by the KLOE experiment at the DA$Φ$NE $φ$-factory. No structures have been observed over the irreducible $μ^+ μ^-$ background. A 90\% CL limit on the ratio…
▽ More
We searched for the $μ^+μ^-$ decay of a light vector gauge boson, also known as dark photon, in the $e^+ e^- \to μ^+ μ^- γ_{\rm ISR}$ process by means of the Initial State Radiation (ISR) method. We used 1.93~fb$^{-1}$ of data collected by the KLOE experiment at the DA$Φ$NE $φ$-factory. No structures have been observed over the irreducible $μ^+ μ^-$ background. A 90\% CL limit on the ratio $\varepsilon^2=α^{\prime}/α$ between the dark coupling constant and the fine structure constant of $ 3\times 10^{-6}-2\times 10^{-7}$ has been set in the dark photon mass region between 519 MeV and 973 MeV. This new limit has been combined with the published result obtained investigating the hypothesis of the dark photon decaying into hadrons in $e^+ e^- \to π^+ π^- γ_{\rm ISR}$ events. The combined 90\% CL limit increases the sensitivity especially in the $ρ-ω$ interference region and excludes $\varepsilon^2$ greater than $(13-2)\times 10^{-7}$. For dark photon masses greater than 600 MeV the combined limit is lower than 8~$\times\, 10^{-7}$ resulting more stringent than present constraints from other experiments.
△ Less
Submitted 9 August, 2018; v1 submitted 7 July, 2018;
originally announced July 2018.
-
Measurement of the charge asymmetry for the $K_S \rightarrow πe ν$ decay and test of CPT symmetry with the KLOE detector
Authors:
A. Anastasi,
D. Babusci,
M. Berłowski,
C. Bloise,
F. Bossi,
P. Branchini,
A. Budano,
B. Cao,
G. Capon,
F. Ceradini,
P. Ciambrone,
F. Curciarello,
E. Czerwiński,
G. D'Agostini,
E. Danè,
V. De Leo,
E. De Lucia,
A. De Santis,
P. De Simone,
A. Di Cicco,
A. Di Domenico,
D. Domenici,
A. D'Uffizi,
A. Fantini,
G. Fantini
, et al. (35 additional authors not shown)
Abstract:
Using 1.63 fb$^{-1}$ of integrated luminosity collected by the KLOE experiment about $7\times 10^4$ $K_S \rightarrow π^{\pm}e^{\mp}ν$ decays have been reconstructed. The measured value of the charge asymmetry for this decay is $A_S = (-4.9 \pm 5.7_{stat} \pm 2.6_{syst}) \times 10^{-3}$, which is almost twice more precise than the previous KLOE result. The combination of these two measurements give…
▽ More
Using 1.63 fb$^{-1}$ of integrated luminosity collected by the KLOE experiment about $7\times 10^4$ $K_S \rightarrow π^{\pm}e^{\mp}ν$ decays have been reconstructed. The measured value of the charge asymmetry for this decay is $A_S = (-4.9 \pm 5.7_{stat} \pm 2.6_{syst}) \times 10^{-3}$, which is almost twice more precise than the previous KLOE result. The combination of these two measurements gives $A_S = (-3.8 \pm 5.0_{stat} \pm 2.6_{syst}) \times 10^{-3}$ and, together with the asymmetry of the $K_L$ semileptonic decay, provides significant tests of the CPT symmetry. The obtained results are in agreement with CPT invariance.
△ Less
Submitted 11 August, 2018; v1 submitted 22 June, 2018;
originally announced June 2018.
-
Feasibility study of the positronium imaging with the J-PET tomograph
Authors:
P. Moskal,
D. Kisielewska,
C. Curceanu,
E. Czerwiński,
K. Dulski,
A. Gajos,
M. Gorgol,
B. Hiesmayr,
B. Jasińska,
K. Kacprzak,
Ł. Kapłon,
G. Korcyl,
P. Kowalski,
W. Krzemień,
T. Kozik,
E. Kubicz,
M. Mohammed,
Sz. Niedźwiecki,
M. Pałka,
M. Pawlik-Niedźwiecka,
L. Raczyński,
J. Raj,
S. Sharma,
Shivani,
R. Y. Shopa
, et al. (5 additional authors not shown)
Abstract:
A detection system of the conventional PET tomograph is set-up to record data from e+ e- annihilation into two photons with energy of 511 keV, and it gives information on the density distribution of a radiopharmaceutical in the body of the object. In this paper we explore the possibility of performing the three gamma photons imaging based on ortho-positronium annihilation, as well as the possibili…
▽ More
A detection system of the conventional PET tomograph is set-up to record data from e+ e- annihilation into two photons with energy of 511 keV, and it gives information on the density distribution of a radiopharmaceutical in the body of the object. In this paper we explore the possibility of performing the three gamma photons imaging based on ortho-positronium annihilation, as well as the possibility of positronium mean lifetime imaging with the J-PET tomograph constructed from plastic scintillators. For this purposes simulations of the ortho-positronium formation and its annihilation into three photons were performed taking into account distributions of photons' momenta as predicted by the theory of quantum electrodynamics and the response of the J-PET tomograph. In order to test the proposed ortho-positronium lifetime image reconstruction method, we concentrate on the decay of the ortho-positronium into three photons and applications of radiopharmaceuticals labeled with isotopes emitting a prompt gamma quantum. The proposed method of imaging is based on the determination of hit-times and hit-positions of registered photons which enables the reconstruction of the time and position of the annihilation point as well as the lifetime of the ortho-positronium on an event-by-event basis. We have simulated the production of the positronium in a cylindrical phantom composed of a set of different materials in which the ortho-positronium lifetime varied from 2.0 ns to 3.0 ns, as expected for ortho-positronium created in the human body. The presented reconstruction method for total-body J-PET like detector allows to achieve a mean lifetime resolution of about 40 ps. Recent Positron Annihilation Lifetime Spectroscopy measurements of cancerous and healthy uterine tissues show that this sensitivity may allow to study the morphological changes in cell structures.
△ Less
Submitted 15 January, 2019; v1 submitted 29 May, 2018;
originally announced May 2018.
-
Backward single-pion production in the $\boldsymbol{pd\rightarrow {}^3\textrm{He}\,π^0}$ reaction with WASA-at-COSY
Authors:
P. Adlarson,
W. Augustyniak,
W. Bardan,
M. Bashkanov,
F. S. Bergmann,
M. Berłowski,
A. Bondar,
M. Büscher,
H. Calén,
I. Ciepał,
H. Clement,
E. Czerwiński,
K. Demmich,
R. Engels,
A. Erven,
W. Erven,
W. Eyrich,
P. Fedorets,
K. Föhl,
K. Fransson,
F. Goldenbaum,
A. Goswami,
K. Grigoryev,
C. -O. Gullström,
L. Heijkenskjöld
, et al. (67 additional authors not shown)
Abstract:
New data on the production of single neutral pions in the $pd\rightarrow{}^3\textrm{He}\,π^0$ reaction are presented. For fifteen proton beam momenta between $p_p=1.60\;\textrm{GeV}/c$ and $p_p=1.74\;\textrm{GeV}/c$, differential cross sections are determined over a large fraction of the backward hemisphere. Since the only previous systematic measurements of single-pion production at these energie…
▽ More
New data on the production of single neutral pions in the $pd\rightarrow{}^3\textrm{He}\,π^0$ reaction are presented. For fifteen proton beam momenta between $p_p=1.60\;\textrm{GeV}/c$ and $p_p=1.74\;\textrm{GeV}/c$, differential cross sections are determined over a large fraction of the backward hemisphere. Since the only previous systematic measurements of single-pion production at these energies were made in collinear kinematics, the present work constitutes a significant extension of the current knowledge on this reaction. Even this far above the production threshold, significant changes are found in the behaviour of the angular distributions over small intervals in beam momentum.
△ Less
Submitted 21 May, 2018;
originally announced May 2018.
-
Feasibility study of the time reversal symmetry tests in decays of metastable positronium atoms with the J-PET detector
Authors:
A. Gajos,
C. Curceanu,
E. Czerwiński,
K. Dulski,
M. Gorgol,
N. Gupta-Sharma,
B. C. Hiesmayr,
B. Jasińska,
K. Kacprzak,
Ł. Kapłon,
D. Kisielewska,
G. Korcyl,
P. Kowalski,
T. Kozik,
W. Krzemień,
E. Kubicz,
M. Mohammed,
Sz. Niedźwiecki,
M. Pałka,
M. Pawlik-Niedźwiecka,
L. Raczyński,
J. Raj,
Z. Rudy,
S. Sharma,
Shivani
, et al. (7 additional authors not shown)
Abstract:
This article reports on the feasibility of testing of the symmetry under reversal in time in a purely leptonic system constituted by positronium atoms using the J-PET detector. The present state of T symmetry tests is discussed with an emphasis on the scarcely explored sector of leptonic systems. Two possible strategies of searching for manifestations of T violation in non-vanishing angular correl…
▽ More
This article reports on the feasibility of testing of the symmetry under reversal in time in a purely leptonic system constituted by positronium atoms using the J-PET detector. The present state of T symmetry tests is discussed with an emphasis on the scarcely explored sector of leptonic systems. Two possible strategies of searching for manifestations of T violation in non-vanishing angular correlations of final state observables in the decays of metastable triplet states of positronium available with J-PET are proposed and discussed. Results of a pilot measurement with J-PET and assessment of its performance in reconstruction of three-photon decays are shown along with an analysis of its impact on the sensitivity of the detector for the determination of T -violation sensitive observables.
△ Less
Submitted 19 April, 2018;
originally announced April 2018.
-
An Isotensor Dibaryon in the $pp \to ppπ^+π^-$ Reaction?
Authors:
P. Adlarson,
W. Augustyniak,
W. Bardan,
M. Bashkanov,
F. S. Bergmann,
M. Berłowski,
A. Bondar,
M. Büscher,
H. Calén,
I. Ciepał,
H. Clement,
E. Czerwiński,
K. Demmich,
R. Engels,
A. Erven,
W. Erven,
W. Eyrich,
P. Fedorets,
K. Föhl,
K. Fransson,
F. Goldenbaum,
A. Goswami,
K. Grigoryev,
L. Heijkenskjöld,
V. Hejny
, et al. (59 additional authors not shown)
Abstract:
Exclusive measurements of the quasi-free $pp \to ppπ^+π^-$ reaction have been carried out at WASA@COSY by means of $pd$ collisions at $T_p$ = 1.2 GeV. Total and differential cross sections have been extracted covering the energy region $T_p = 1.08 - 1.36$ GeV, which is the region of $N^*(1440)$ and $Δ(1232)Δ(1232)$ resonance excitations. Calculations describing these excitations by $t$-channel mes…
▽ More
Exclusive measurements of the quasi-free $pp \to ppπ^+π^-$ reaction have been carried out at WASA@COSY by means of $pd$ collisions at $T_p$ = 1.2 GeV. Total and differential cross sections have been extracted covering the energy region $T_p = 1.08 - 1.36$ GeV, which is the region of $N^*(1440)$ and $Δ(1232)Δ(1232)$ resonance excitations. Calculations describing these excitations by $t$-channel meson exchange are at variance with the measured differential cross sections and underpredict substantially the experimental total cross section. An isotensor $ΔN$ dibaryon resonance with $I(J^P) = 2(1^+)$ produced associatedly with a pion is able to overcome these deficiencies.
△ Less
Submitted 27 June, 2018; v1 submitted 8 March, 2018;
originally announced March 2018.
-
On the Production of an Isotensor Dibaryon in the $pp \to ppπ^+π^-$ Reaction
Authors:
P. Adlarson,
W. Augustyniak,
W. Bardan,
M. Bashkanov,
F. S. Bergmann,
M. Berłowski,
A. Bondar,
M. Büscher,
H. Calén,
I. Ciepał,
H. Clement,
E. Czerwiński,
K. Demmich,
R. Engels,
A. Erven,
W. Erven,
W. Eyrich,
P. Fedorets,
K. Föhl,
K. Fransson,
F. Goldenbaum,
A. Goswami,
K. Grigoryev,
L. Heijkenskjöld,
V. Hejny
, et al. (59 additional authors not shown)
Abstract:
Exclusive measurements of the quasi-free $pp \to ppπ^+π^-$ reaction have been performed by means of $pd$ collisions at $T_p$ = 1.2 GeV using the WASA detector setup at COSY. Total and differential cross sections have been obtained covering the energy region $T_p = 1.08 - 1.36$ GeV ($\sqrt s$ = 2.35 - 2.46 GeV), which includes the regions of $N^*(1440)$ and $Δ(1232)Δ(1232)$ resonance excitations. C…
▽ More
Exclusive measurements of the quasi-free $pp \to ppπ^+π^-$ reaction have been performed by means of $pd$ collisions at $T_p$ = 1.2 GeV using the WASA detector setup at COSY. Total and differential cross sections have been obtained covering the energy region $T_p = 1.08 - 1.36$ GeV ($\sqrt s$ = 2.35 - 2.46 GeV), which includes the regions of $N^*(1440)$ and $Δ(1232)Δ(1232)$ resonance excitations. Calculations describing these excitations by $t$-channel meson exchange are at variance with experimental differential cross sections and underpredict substantially the measured total cross section. An isotensor $ΔN$ dibaryon resonance with $I(J^P) = 2(1^+)$ produced associatedly with a pion is able to overcome these deficiencies. Such a dibaryon was predicted by Dyson and Xuong and more recently calculated by Gal and Garcilazo.
△ Less
Submitted 10 August, 2018; v1 submitted 8 March, 2018;
originally announced March 2018.
-
Towards 2+1 photon tomography: Energy-based selection of two 511 keV photons and a prompt photon with the J-PET scanner
Authors:
R. Masełek,
W. Krzemien,
K. Klimaszewski,
L. Raczyński,
P. Kowalski,
R. Shopa,
W. Wiślicki,
P. Białas,
C. Curceanu,
E. Czerwiński,
K. Dulski,
A. Gajos,
B. Głowacz,
M. Gorgol,
B. Hiesmayr,
B. Jasińska,
D. Kisielewska,
G. Korcyl,
T. Kozik,
N. Krawczyk,
E. Kubicz,
M. Mohammed,
M. Pawlik-Niedźwiecka,
S. Niedźwiecki,
M. Pałka
, et al. (9 additional authors not shown)
Abstract:
The possibility to separate signals caused by 511 keV photons created in annihilation of electron-positron pairs and the so-called prompt photons from nuclei de- excitation is investigated. It could potentially be used to improve the quality of reconstructed images in the J-PET scanner in 2+1 photon tomography. Firstly, a research is conducted for several radioisotopes that decay via \b{eta}+ deca…
▽ More
The possibility to separate signals caused by 511 keV photons created in annihilation of electron-positron pairs and the so-called prompt photons from nuclei de- excitation is investigated. It could potentially be used to improve the quality of reconstructed images in the J-PET scanner in 2+1 photon tomography. Firstly, a research is conducted for several radioisotopes that decay via \b{eta}+ decay followed by de-excitation of an excited nucleus. Efficiency, purity and false positive rate are calculated for each isotope as a function of energy deposited threshold, with a hypothesis that signals caused by 511 keV photons deposit smaller values of energy than 1 z 13the selected threshold, while prompt photons deposit larger energy than the threshold. Analysis of the results accompanied with physical properties of radioisotopes suggests using 44 Sc, which is the most promising candidate for medical applications. With the use of GATE and J-POS simulation software, in-phantom scattering was introduced and the best energy deposited threshold value was estimated to be approximately 375 keV. It corresponds to almost 100% efficiency for 511 keV signals, 75% purity for 511 keV photons, and approximately 70% efficiency and purity for prompt photons.
△ Less
Submitted 2 March, 2018;
originally announced March 2018.
-
Search for $C$ violation in the decay $η\rightarrowπ^0+e^++e^-$ with WASA-at-COSY
Authors:
P. Adlarson,
W. Augustyniak,
W. Bardan,
M. Bashkanov,
F. S. Bergmann,
M. Berłowski,
A. Bondar,
M. Büscher,
H. Calén,
I. Ciepał,
H. Clement,
E. Czerwiński,
K. Demmich,
R. Engels,
A. Erven,
W. Erven,
W. Eyrich,
P. Fedorets,
K. Föhl,
K. Fransson,
F. Goldenbaum,
A. Goswami,
K. Grigoryev,
C. -O. Gullström,
C. Hanhart
, et al. (68 additional authors not shown)
Abstract:
We report on the investigation of the rare decay $η\rightarrowπ^0+\text{e}^++\text{e}^-$ which is of interest to study both $C$ violation in the electromagnetic interaction and to search for contributions from physics beyond the Standard Model, since the allowed decay via a two-photon intermediate state is strongly suppressed. The experiment has been performed using the WASA-at-COSY installation,…
▽ More
We report on the investigation of the rare decay $η\rightarrowπ^0+\text{e}^++\text{e}^-$ which is of interest to study both $C$ violation in the electromagnetic interaction and to search for contributions from physics beyond the Standard Model, since the allowed decay via a two-photon intermediate state is strongly suppressed. The experiment has been performed using the WASA-at-COSY installation, located at the COSY accelerator of the Forschungszentrum Jülich, Germany. In total $3\times10^7$ events of the reaction $\text{p}+\text{d}\rightarrow{^3\text{He}}+η$ have been recorded at an excess energy of $Q = 59.8\,\textrm{MeV}$. Based on this data set the $C$ parity violating decay $η\rightarrowπ^0+γ^*\rightarrowπ^0+\textrm{e}^++\textrm{e}^-$ via a single-photon intermediate state has been searched for, resulting in new upper limits of $Γ\left(η\rightarrowπ^0+\textrm{e}^++\textrm{e}^-\right)/ Γ\left(η\rightarrowπ^++π^-+π^0\right) < 3.28\times10^{-5}$ and $Γ\left(η\rightarrowπ^0+\textrm{e}^++\textrm{e}^-\right)/ Γ\left(η\rightarrow\textrm{all}\right) < 7.5\times10^{-6}\ (\textrm{CL} = 90\,\%)$, respectively.
△ Less
Submitted 23 February, 2018;
originally announced February 2018.
-
Total and differential cross sections of $η$-production in proton-deuteron fusion for excess energies between $Q_η=13\;\text{MeV}$ and $Q_η=81\;\text{MeV}$
Authors:
P. Adlarson,
W. Augustyniak,
W. Bardan,
M. Bashkanov,
F. S. Bergmann,
M. Berłowski,
A. Bondar,
M. Büscher,
H. Calén,
I. Ciepał,
H. Clement,
E. Czerwiński,
K. Demmich,
R. Engels,
A. Erven,
W. Erven,
W. Eyrich,
P. Fedorets,
K. Föhl,
K. Fransson,
F. Goldenbaum,
A. Goswami,
K. Grigoryev,
C. -O. Gullström,
C. Hanhart
, et al. (68 additional authors not shown)
Abstract:
New data on both total and differential cross sections of the production of $η$ mesons in proton-deuteron fusion to ${}^3\text{He}\,η$ in the excess energy region $13.6\;\text{MeV}\leq Q_η\leq 80.9\;\text{MeV}$ are presented. These data have been obtained with the WASA-at-COSY detector setup located at the Forschungszentrum Jülich, using a proton beam at 15 different beam momenta between…
▽ More
New data on both total and differential cross sections of the production of $η$ mesons in proton-deuteron fusion to ${}^3\text{He}\,η$ in the excess energy region $13.6\;\text{MeV}\leq Q_η\leq 80.9\;\text{MeV}$ are presented. These data have been obtained with the WASA-at-COSY detector setup located at the Forschungszentrum Jülich, using a proton beam at 15 different beam momenta between $p_p = 1.60\;\text{GeV}/c$ and $p_p = 1.74\;\text{GeV}/c$. While significant structure of the total cross section is observed in the energy region $20\;\text{MeV}\lesssim Q_η\lesssim 60\;\text{MeV}$, a previously reported sharp variation around $Q_η\approx 50\;\text{MeV}$ cannot be confirmed. Angular distributions show the typical forward-peaking that was reported elsewhere. For the first time, it is possible to study the development of these angular distributions with rising excess energy over a large interval.
△ Less
Submitted 20 January, 2018;
originally announced January 2018.
-
Human Tissues Investigation Using PALS Technique
Authors:
B. Jasińska,
B. Zgardzińska,
G. Chołubek,
M. Gorgol,
K. Wiktor,
K. Wysogld,
P. Białas,
C. Curceanu,
E. Czerwiński,
K. Dulski,
A. Gajos,
B. Głowacz,
B. Hiesmayr,
B. Jodłowska-Jędrych,
D. Kamińska,
G. Korcyl,
P. Kowalski,
T. Kozik,
N. Krawczyk,
W. Krzemień,
E. Kubicz,
M. Mohammed,
M. Pawlik-Niedźwiecka,
S. Niedźwiecki,
M. Pałka
, et al. (12 additional authors not shown)
Abstract:
Samples of uterine leiomyomatis and normal tissues taken from patients after surgery were investigated using the Positron Annihilation Lifetime Spectroscopy (PALS). Significant differences in all PALS parameters between normal and diseased tissues were observed. For all studied patients, it was found that the values of the free annihilation and ortho-positronium lifetime are larger for the tumorou…
▽ More
Samples of uterine leiomyomatis and normal tissues taken from patients after surgery were investigated using the Positron Annihilation Lifetime Spectroscopy (PALS). Significant differences in all PALS parameters between normal and diseased tissues were observed. For all studied patients, it was found that the values of the free annihilation and ortho-positronium lifetime are larger for the tumorous tissues than for the healthy ones. For most of the patients, the intensity of the free annihilation and ortho-positronium annihilation was smaller for the tumorous than for the healthy tissues. For the first time, in this kind of studies, the $3γ$ fraction of positron annihilation was determined to describe changes in the tissue porosity during morphologic alteration.
△ Less
Submitted 13 November, 2017;
originally announced November 2017.
-
Combination of KLOE $σ\big(e^+e^-\rightarrowπ^+π^-γ(γ)\big)$ measurements and determination of $a_μ^{π^+π^-}$ in the energy range $0.10 < s < 0.95$ GeV$^2$
Authors:
The KLOE-2 Collaboration,
:,
A. Anastasi,
D. Babusci,
M. Berlowski,
C. Bloise,
F. Bossi,
P. Branchini,
A. Budano,
L. Caldeira Balkeståhl,
B. Cao,
F. Ceradini,
P. Ciambrone,
F. Curciarello,
E. Czerwiński,
G. D'Agostini,
E. Danè,
V. De Leo,
E. De Lucia,
A. De Santis,
P. De Simone,
A. Di Cicco,
A. Di Domenico,
D. Domenici,
A. D'Uffizi
, et al. (41 additional authors not shown)
Abstract:
The three precision measurements of the cross section $σ\big(e^+e^-\rightarrowπ^+π^-γ(γ)\big)$ using initial state radiation by the KLOE collaboration provide an important input for the prediction of the hadronic contribution to the anomalous magnetic moment of the muon. These measurements are correlated for both statistical and systematic uncertainties and, therefore, the simultaneous use of thes…
▽ More
The three precision measurements of the cross section $σ\big(e^+e^-\rightarrowπ^+π^-γ(γ)\big)$ using initial state radiation by the KLOE collaboration provide an important input for the prediction of the hadronic contribution to the anomalous magnetic moment of the muon. These measurements are correlated for both statistical and systematic uncertainties and, therefore, the simultaneous use of these measurements requires covariance matrices that fully describe the correlations. We present the construction of these covariance matrices and use them to determine a combined KLOE measurement for $σ\big(e^+e^-\rightarrowπ^+π^-γ(γ)\big)$. We find, from this combination, a two-pion contribution to the muon magnetic anomaly in the energy range $0.10 < s < 0.95$ GeV$^2$ of $a_μ^{π^+π^-} = (489.8 \pm 1.7_{\rm stat} \pm 4.8_{\rm sys} ) \times 10^{-10}$.
△ Less
Submitted 8 June, 2018; v1 submitted 8 November, 2017;
originally announced November 2017.
-
Introduction of total variation regularization into filtered backprojection algorithm
Authors:
L. Raczyński,
W. Wiślicki,
K. Klimaszewski,
W. Krzemień,
P. Kowalski,
R. Shopa,
P. Białas,
C. Curceanu,
E. Czerwiński,
K. Dulski,
A. Gajos,
B. Głowacz,
M. Gorgol,
B. Hiesmayr,
B. Jasińska,
D. Kisielewska-Kamińska,
G. Korcyl,
T. Kozik,
N. Krawczyk,
E. Kubicz,
M. Mohammed,
M. Pawlik-Niedźwiecka,
S. Niedźwiecki,
M. Pałka,
Z. Rudy
, et al. (8 additional authors not shown)
Abstract:
In this paper we extend the state-of-the-art filtered backprojection (FBP) method with application of the concept of Total Variation regularization. We compare the performance of the new algorithm with the most common form of regularizing in the FBP image reconstruction via apodizing functions. The methods are validated in terms of cross-correlation coefficient between reconstructed and real image…
▽ More
In this paper we extend the state-of-the-art filtered backprojection (FBP) method with application of the concept of Total Variation regularization. We compare the performance of the new algorithm with the most common form of regularizing in the FBP image reconstruction via apodizing functions. The methods are validated in terms of cross-correlation coefficient between reconstructed and real image of radioactive tracer distribution using standard Derenzo-type phantom. We demonstrate that the proposed approach results in higher cross-correlation values with respect to the standard FBP method.
△ Less
Submitted 31 October, 2017;
originally announced November 2017.
-
J-PET: a new technology for the whole-body PET imaging
Authors:
S. Niedźwiecki,
P. Białas,
C. Curceanu,
E. Czerwiński,
K. Dulski,
A. Gajos,
B. Głowacz,
M. Gorgol,
B. C. Hiesmayr,
B. Jasińska,
Ł. Kapłon,
D. Kisielewska-Kamińska,
G. Korcyl,
P. Kowalski,
T. Kozik,
N. Krawczyk,
W. Krzemień,
E. Kubicz,
M. Mohammed,
M. Pawlik-Niedźwiecka,
M. Pałka,
L. Raczyński,
Z. Rudy,
N. G. Sharma,
S. Sharma
, et al. (8 additional authors not shown)
Abstract:
The Jagiellonian Positron Emission Tomograph (J-PET) is the first PET built from plastic scintillators. J-PET prototype consists of 192 detection modules arranged axially in three layers forming a cylindrical diagnostic chamber with the inner diameter of 85 cm and the axial field-of-view of 50 cm. An axial arrangement of long strips of plastic scintillators, their small light attenuation, superior…
▽ More
The Jagiellonian Positron Emission Tomograph (J-PET) is the first PET built from plastic scintillators. J-PET prototype consists of 192 detection modules arranged axially in three layers forming a cylindrical diagnostic chamber with the inner diameter of 85 cm and the axial field-of-view of 50 cm. An axial arrangement of long strips of plastic scintillators, their small light attenuation, superior timing properties, and relative ease of the increase of the axial field-of-view opens promising perspectives for the cost effective construction of the whole-body PET scanner, as well as construction of MR and CT compatible PET inserts. Present status of the development of the J-PET tomograph will be presented and discussed.
△ Less
Submitted 31 October, 2017;
originally announced October 2017.
-
Commissioning of the J-PET detector for studies of decays of positronium atoms
Authors:
E. Czerwiński,
K. Dulski,
P. Białas,
C. Curceanu,
A. Gajos,
B. Głowacz,
M. Gorgol,
B. C. Hiesmayr,
B. Jasińska,
D. Kisielewska,
G. Korcyl,
P. Kowalski,
T. Kozik,
N. Krawczyk,
W. Krzemień,
E. Kubicz,
M. Mohammed,
Sz. Niedźwiecki,
M. Pałka,
M. Pawlik-Niedźwiecka,
L. Raczyński,
Z. Rudy,
N. G. Sharma,
S. Sharma,
R. Y. Shopa
, et al. (7 additional authors not shown)
Abstract:
The Jagiellonian Positron Emission Tomograph (J-PET) is a detector for medical imaging of the whole human body as well as for physics studies involving detection of electron-positron annihilation into photons. J-PET has high angular and time resolution and allows for measurement of spin of the positronium and the momenta and polarization vectors of annihilation quanta. In this article, we present…
▽ More
The Jagiellonian Positron Emission Tomograph (J-PET) is a detector for medical imaging of the whole human body as well as for physics studies involving detection of electron-positron annihilation into photons. J-PET has high angular and time resolution and allows for measurement of spin of the positronium and the momenta and polarization vectors of annihilation quanta. In this article, we present the potential of the J-PET system for background rejection in the decays of positronium atoms.
△ Less
Submitted 13 November, 2017; v1 submitted 30 October, 2017;
originally announced October 2017.
-
Three-dimensional image reconstruction in J-PET using Filtered Back Projection method
Authors:
R. Y. Shopa,
K. Klimaszewski,
P. Kowalski,
W. Krzemień,
L. Raczyński,
W. Wiślicki,
P. Białas,
C. Curceanu,
E. Czerwiński,
K. Dulski,
A. Gajos,
B. Głowacz,
M. Gorgol,
B. Hiesmayr,
B. Jasińska,
D. Kisielewska-Kamińska,
G. Korcyl,
T. Kozik,
N. Krawczyk,
E. Kubicz,
M. Mohammed,
M. Pawlik-Niedźwiecka,
S. Niedźwiecki,
M. Pałka,
Z. Rudy
, et al. (8 additional authors not shown)
Abstract:
We present a method and preliminary results of the image reconstruction in the Jagiellonian PET tomograph. Using GATE (Geant4 Application for Tomographic Emission), interactions of the 511 keV photons with a cylindrical detector were generated. Pairs of such photons, flying back-to-back, originate from e+e- annihilations inside a 1-mm spherical source. Spatial and temporal coordinates of hits were…
▽ More
We present a method and preliminary results of the image reconstruction in the Jagiellonian PET tomograph. Using GATE (Geant4 Application for Tomographic Emission), interactions of the 511 keV photons with a cylindrical detector were generated. Pairs of such photons, flying back-to-back, originate from e+e- annihilations inside a 1-mm spherical source. Spatial and temporal coordinates of hits were smeared using experimental resolutions of the detector. We incorporated the algorithm of the 3D Filtered Back Projection, implemented in the STIR and TomoPy software packages, which differ in approximation methods. Consistent results for the Point Spread Functions of ~5/7,mm and ~9/20, mm were obtained, using STIR, for transverse and longitudinal directions, respectively, with no time of flight information included.
△ Less
Submitted 30 October, 2017;
originally announced October 2017.