-
Heterodyne dispersive cavity ring-down spectroscopy exploiting eigenmode frequencies for high-fidelity measurements
Authors:
Agata Cygan,
Szymon Wójtewicz,
Hubert Jóźwiak,
Grzegorz Kowzan,
Nikodem Stolarczyk,
Katarzyna Bielska,
Piotr Wcisło,
Roman Ciuryło,
Daniel Lisak
Abstract:
Measuring low light absorption with combined uncertainty < 1 permille is crucial in a wide range of applications. Popular cavity ring-down spectroscopy can provide ultra-high precision, below 0.01 permille, but its accuracy is strongly dependent on the measurement capabilities of the detection system and typically is about 10 permille. Here, we exploit the optical frequency information carried by…
▽ More
Measuring low light absorption with combined uncertainty < 1 permille is crucial in a wide range of applications. Popular cavity ring-down spectroscopy can provide ultra-high precision, below 0.01 permille, but its accuracy is strongly dependent on the measurement capabilities of the detection system and typically is about 10 permille. Here, we exploit the optical frequency information carried by the ring-down cavity electromagnetic field, not explored in conventional CRDS, for high-fidelity spectroscopy. Instead of measuring only the decaying light intensity, we perform heterodyne detection of ring-downs followed by Fourier analysis to provide exact frequencies of optical cavity modes and a dispersive spectrum of a gas sample from them. This approach is insensitive to inaccuracies in light intensity measurements and eliminates the problem of detector band nonlinearity, the main cause of measurement error in traditional CRDS. Using the CO and HD line intensities as examples, we demonstrate the sub-permille accuracy of our method, confirmed by the best ab initio results, and the long-term repeatability of our dispersion measurements at 10^(-4) level. Such results have not been achieved in optical spectroscopy before. The high accuracy of the presented method indicates its potential in atmospheric studies, isotope ratio metrology, thermometry, and the establishment of primary gas standards.
△ Less
Submitted 4 March, 2024;
originally announced March 2024.
-
Development of a Realistic Crowd Simulation Environment for Fine-grained Validation of People Tracking Methods
Authors:
Paweł Foszner,
Agnieszka Szczęsna,
Luca Ciampi,
Nicola Messina,
Adam Cygan,
Bartosz Bizoń,
Michał Cogiel,
Dominik Golba,
Elżbieta Macioszek,
Michał Staniszewski
Abstract:
Generally, crowd datasets can be collected or generated from real or synthetic sources. Real data is generated by using infrastructure-based sensors (such as static cameras or other sensors). The use of simulation tools can significantly reduce the time required to generate scenario-specific crowd datasets, facilitate data-driven research, and next build functional machine learning models. The mai…
▽ More
Generally, crowd datasets can be collected or generated from real or synthetic sources. Real data is generated by using infrastructure-based sensors (such as static cameras or other sensors). The use of simulation tools can significantly reduce the time required to generate scenario-specific crowd datasets, facilitate data-driven research, and next build functional machine learning models. The main goal of this work was to develop an extension of crowd simulation (named CrowdSim2) and prove its usability in the application of people-tracking algorithms. The simulator is developed using the very popular Unity 3D engine with particular emphasis on the aspects of realism in the environment, weather conditions, traffic, and the movement and models of individual agents. Finally, three methods of tracking were used to validate generated dataset: IOU-Tracker, Deep-Sort, and Deep-TAMA.
△ Less
Submitted 26 April, 2023;
originally announced April 2023.
-
CrowdSim2: an Open Synthetic Benchmark for Object Detectors
Authors:
Paweł Foszner,
Agnieszka Szczęsna,
Luca Ciampi,
Nicola Messina,
Adam Cygan,
Bartosz Bizoń,
Michał Cogiel,
Dominik Golba,
Elżbieta Macioszek,
Michał Staniszewski
Abstract:
Data scarcity has become one of the main obstacles to develo** supervised models based on Artificial Intelligence in Computer Vision. Indeed, Deep Learning-based models systematically struggle when applied in new scenarios never seen during training and may not be adequately tested in non-ordinary yet crucial real-world situations. This paper presents and publicly releases CrowdSim2, a new synth…
▽ More
Data scarcity has become one of the main obstacles to develo** supervised models based on Artificial Intelligence in Computer Vision. Indeed, Deep Learning-based models systematically struggle when applied in new scenarios never seen during training and may not be adequately tested in non-ordinary yet crucial real-world situations. This paper presents and publicly releases CrowdSim2, a new synthetic collection of images suitable for people and vehicle detection gathered from a simulator based on the Unity graphical engine. It consists of thousands of images gathered from various synthetic scenarios resembling the real world, where we varied some factors of interest, such as the weather conditions and the number of objects in the scenes. The labels are automatically collected and consist of bounding boxes that precisely localize objects belonging to the two object classes, leaving out humans from the annotation pipeline. We exploited this new benchmark as a testing ground for some state-of-the-art detectors, showing that our simulated scenarios can be a valuable tool for measuring their performances in a controlled environment.
△ Less
Submitted 11 April, 2023;
originally announced April 2023.
-
Sub-promille measurements and calculations of CO (3--0) overtone line intensities
Authors:
K. Bielska,
A. A. Kyuberis,
Z. D. Reed,
Gang Li,
A. Cygan,
R. Ciuryło,
D. Lisak,
E. M. Adkins,
L. Lodi,
J. T. Hodges,
V. Ebert,
N. F. Zobov,
J. Tennyson,
O. L. Polyansky
Abstract:
Intensities of lines in the near-infrared second overtone band (3--0) of $^{12}$C$^{16}$O are measured and calculated to an unprecedented degree of precision and accuracy. Agreement between theory and experiment to better than 1 $\permil$ is demonstrated by results from two laboratories involving two independent absorption- and dispersion-based cavity-enhanced techniques. Similarly, independent Fo…
▽ More
Intensities of lines in the near-infrared second overtone band (3--0) of $^{12}$C$^{16}$O are measured and calculated to an unprecedented degree of precision and accuracy. Agreement between theory and experiment to better than 1 $\permil$ is demonstrated by results from two laboratories involving two independent absorption- and dispersion-based cavity-enhanced techniques. Similarly, independent Fourier transform spectroscopy measurements of stronger lines in this band yield mutual agreement and consistency with theory at the 1 $\permil$ level. This set of highly accurate intensities can provide an intrinsic reference for reducing biases in future measurements of spectroscopic peak areas.
△ Less
Submitted 27 July, 2022;
originally announced July 2022.
-
Dual-comb cavity ring-down spectroscopy
Authors:
D. Lisak,
D. Charczun,
A. Nishiyama,
T. Voumard,
T. Wildi,
G. Kowzan,
V. Brasch,
T. Herr,
A. J. Fleisher,
J. T. Hodges,
R. Ciuryło,
A. Cygan,
P. Masłowski
Abstract:
Cavity ring-down spectroscopy is a ubiquitous optical method used to study light-matter interactions with high resolution, sensitivity and accuracy. However, it has never been performed with the multiplexing advantages of direct frequency comb spectroscopy without sacrificing orders of magnitude of resolution. We present dual-comb cavity ring-down spectroscopy (DC-CRDS) based on the parallel heter…
▽ More
Cavity ring-down spectroscopy is a ubiquitous optical method used to study light-matter interactions with high resolution, sensitivity and accuracy. However, it has never been performed with the multiplexing advantages of direct frequency comb spectroscopy without sacrificing orders of magnitude of resolution. We present dual-comb cavity ring-down spectroscopy (DC-CRDS) based on the parallel heterodyne detection of ring-down signals with a local oscillator comb to yield absorption and dispersion spectra. These spectra are obtained from widths and positions of cavity modes. We present two approaches which leverage the dynamic cavity response to coherently or randomly driven changes in the amplitude or frequency of the probe field. Both techniques yield accurate spectra of methane - an important greenhouse gas and breath biomarker. The high sensitivity and accuracy of broadband DC-CRDS, shows promise for applications like studies of the structure and dynamics of large molecules, multispecies trace gas detection and isotopic composition.
△ Less
Submitted 14 June, 2021;
originally announced June 2021.
-
Ultra-high finesse cavity-enhanced spectroscopy for accurate tests of quantum electrodynamics for molecules
Authors:
M. Zaborowski,
M. Słowiński,
K. Stankiewicz,
F. Thibault,
A. Cygan,
H. Jóźwiak,
G. Kowzan,
P. Masłowski,
A. Nishiyama,
N. Stolarczyk,
S. Wójtewicz,
R. Ciuryło,
D. Lisak,
P. Wcisło
Abstract:
We report the most accurate measurement of the position of the weak quadrupole S(2) 2-0 line in D$_2$. The spectra were collected with a frequency-stabilized cavity ring-down spectrometer (FS-CRDS) with an ultra-high finesse optical cavity ($\mathcal{F}$ = 637 000) and operating in the frequency-agile, rapid scanning spectroscopy (FARS) mode. Despite working in the Doppler-limited regime, we reach…
▽ More
We report the most accurate measurement of the position of the weak quadrupole S(2) 2-0 line in D$_2$. The spectra were collected with a frequency-stabilized cavity ring-down spectrometer (FS-CRDS) with an ultra-high finesse optical cavity ($\mathcal{F}$ = 637 000) and operating in the frequency-agile, rapid scanning spectroscopy (FARS) mode. Despite working in the Doppler-limited regime, we reached 40 kHz of statistical uncertainty and 161 kHz of absolute accuracy, achieving the highest accuracy for homonuclear isotopologues of molecular hydrogen. The accuracy of our measurement corresponds to the fifth significant digit of the leading term in QED correction. We observe 2.3$σ$ discrepancy with the recent theoretical value.
△ Less
Submitted 27 January, 2020;
originally announced January 2020.
-
Cavity buildup dispersion spectroscopy
Authors:
A. Cygan,
A. J. Fleisher,
R. Ciuryło,
K. A. Gillis,
J. T. Hodges,
D. Lisak
Abstract:
Measurements of ultrahigh-fidelity absorption spectra can help validate quantum theory, engineer ultracold chemistry, and remotely sense atmospheres. Recent achievements in cavity-enhanced spectroscopy using either frequency-based dispersion or time-based absorption approaches have set new records for accuracy with uncertainties at the sub-per-mil level. However, laser scanning5 or susceptibility…
▽ More
Measurements of ultrahigh-fidelity absorption spectra can help validate quantum theory, engineer ultracold chemistry, and remotely sense atmospheres. Recent achievements in cavity-enhanced spectroscopy using either frequency-based dispersion or time-based absorption approaches have set new records for accuracy with uncertainties at the sub-per-mil level. However, laser scanning5 or susceptibility to nonlinearities limits their ultimate performance. Here we present cavity buildup dispersion spectroscopy (CBDS) in which the dispersive frequency shift of a cavity resonance is encoded in the cavity's transient response to a phase-locked non-resonant laser excitation. Beating between optical frequencies during buildup exactly localizes detuning from mode center, and thus enables single-shot dispersion measurements. CBDS yields an accuracy limited by the chosen frequency standard, a speed limited by the cavity round-trip time, and is currently 50 times less susceptible to detection nonlinearity compared to intensity-based methods. The universality of CBDS shows promise for improving fundamental research into a variety of light-matter interactions.
△ Less
Submitted 23 January, 2020;
originally announced January 2020.
-
Absolute frequency determination of molecular transition in the Doppler regime at kHz level of accuracy
Authors:
K. Bielska,
S. Wojtewicz,
P. Morzynski,
P. Ablewski,
A. Cygan,
M. Bober,
M. Zawada,
R. Ciurylo,
P. Maslowski,
D. Lisak
Abstract:
We present absolute frequency measurement of the unperturbed P7 P7 O$_2$ B-band transition with relative standard uncertainty of $2\times10^{-11}$. We reached the level of accuracy typical for Doppler-free techniques, with Doppler-limited spectroscopy. The Doppler-limited shapes of the P7 P7 spectral line were measured with a frequency-stabilized cavity ring-down spectrometer referenced to an…
▽ More
We present absolute frequency measurement of the unperturbed P7 P7 O$_2$ B-band transition with relative standard uncertainty of $2\times10^{-11}$. We reached the level of accuracy typical for Doppler-free techniques, with Doppler-limited spectroscopy. The Doppler-limited shapes of the P7 P7 spectral line were measured with a frequency-stabilized cavity ring-down spectrometer referenced to an $^{88}$Sr optical atomic clock by an optical frequency comb.
△ Less
Submitted 16 August, 2017; v1 submitted 18 May, 2017;
originally announced May 2017.
-
Fibre-optic delivery of time and frequency to VLBI station
Authors:
P. Krehlik,
Ł. Buczek,
J. Kołodziej,
M. Lipiński,
Ł. Śliwczyński,
J. Nawrocki,
P. Nogaś,
A. Marecki,
E. Pazderski,
P. Ablewski,
M. Bober,
R. Ciuryło,
A. Cygan,
D. Lisak,
P. Masłowski,
P. Morzyński,
M. Zawada,
R. M. Campbell,
J. Pieczerak,
A. Binczewski,
K. Turza
Abstract:
The quality of Very Long Baseline Interferometry (VLBI) radio observations predominantly relies on precise and ultra-stable time and frequency (T&F) standards, usually hydrogen masers (HM), maintained locally at each VLBI station. Here, we present an operational solution in which the VLBI observations are routinely carried out without use of a local HM, but using remote synchronization via a stabi…
▽ More
The quality of Very Long Baseline Interferometry (VLBI) radio observations predominantly relies on precise and ultra-stable time and frequency (T&F) standards, usually hydrogen masers (HM), maintained locally at each VLBI station. Here, we present an operational solution in which the VLBI observations are routinely carried out without use of a local HM, but using remote synchronization via a stabilized, long-distance fibre-optic link. The T&F reference signals, traceable to international atomic timescale (TAI), are delivered to the VLBI station from a dedicated timekee** laboratory. Moreover, we describe a proof-of-concept experiment where the VLBI station is synchronized to a remote strontium optical lattice clock during the observation.
△ Less
Submitted 7 July, 2017; v1 submitted 28 March, 2017;
originally announced March 2017.
-
Searching for topological defect dark matter with optical atomic clocks
Authors:
Piotr Wcislo,
Piotr Morzynski,
Marcin Bober,
Agata Cygan,
Daniel Lisak,
Roman Ciurylo,
Michal Zawada
Abstract:
The total mass density of the Universe appears to be dominated by dark matter. However, beyond its gravitational interactions at the galactic scale, little is known about its nature. Extensions of the quantum electrodynamics Lagrangian with dark-matter coupling terms may result in changes to Standard Model parameters. Recently, it was proposed that a network of atomic clocks could be used to searc…
▽ More
The total mass density of the Universe appears to be dominated by dark matter. However, beyond its gravitational interactions at the galactic scale, little is known about its nature. Extensions of the quantum electrodynamics Lagrangian with dark-matter coupling terms may result in changes to Standard Model parameters. Recently, it was proposed that a network of atomic clocks could be used to search for transient signals of a hypothetical dark matter in the form of stable topological defects. The clocks become desynchronized when a dark-matter object sweeps through the network. This pioneering approach, which is applicable only for distant clocks, is limited by the quality of the fibre links. Here, we present an alternative experimental approach that is applicable to both closely spaced and distant optical atomic clocks and benefits from their individual susceptibilities to dark matter, hence not requiring fibre links. We explore a new dimension of astrophysical observations by constraining the strength of atomic coupling to the hypothetical dark-matter cosmic objects. Our experimental constraint exceeds the previous limits; in fact, it not only reaches the ultimate level expected to be achievable with a constellation of GPS atomic clocks but also has a large potential for improvement.
△ Less
Submitted 2 September, 2016; v1 submitted 18 May, 2016;
originally announced May 2016.
-
Absolute measurement of the ${}^{1}S_{0}$ - ${}^{3}P_{0}$ clock transition in neutral ${}^{88}$Sr over the 330 km-long stabilized fibre optic link
Authors:
Piotr Morzynski,
Marcin Bober,
Dobroslawa Bartoszek-Bober,
Jerzy Nawrocki,
Przemyslaw Krehlik,
Lukasz Sliwczynski,
Marcin Lipinski,
Piotr Maslowski,
Agata Cygan,
Piotr Dunst,
Michal Garus,
Daniel Lisak,
Jerzy Zachorowski,
Wojciech Gawlik,
Czeslaw Radzewicz,
Roman Ciurylo,
Michal Zawada
Abstract:
We report a stability below $7\times 10{}^{-17}$ of two independent optical lattice clocks operating with bosonic ${}^{88}$Sr isotope. The value (429228066418008.3(1.9)${}_{syst}$(0.9)${}_{stat}$~Hz) of the absolute frequency of the ${}^{1}S_{0}$ - ${}^{3}P_{0}$ transition was measured with an optical frequency comb referenced to the local representation of the UTC by the 330 km-long stabilized fi…
▽ More
We report a stability below $7\times 10{}^{-17}$ of two independent optical lattice clocks operating with bosonic ${}^{88}$Sr isotope. The value (429228066418008.3(1.9)${}_{syst}$(0.9)${}_{stat}$~Hz) of the absolute frequency of the ${}^{1}S_{0}$ - ${}^{3}P_{0}$ transition was measured with an optical frequency comb referenced to the local representation of the UTC by the 330 km-long stabilized fibre optical link. The result was verified by series of measurements on two independent optical lattice clocks and agrees with recommendation of Bureau International des Poids et Mesures.
△ Less
Submitted 7 December, 2015;
originally announced December 2015.
-
Strontium optical lattice clocks for practical realization of the metre and secondary representation of the second
Authors:
M. Bober,
P. Morzyński,
A. Cygan,
D. Lisak,
P. Masłowski,
M. Prymaczek,
P. Wcisło,
P. Ablewski,
M. Piwiński,
S. Wójtewicz,
K. Bielska,
D. Bartoszek-Bober,
R. Trawiński,
M. Zawada,
R. Ciuryło,
J. Zachorowski,
M. Piotrowski,
W. Gawlik,
F. Ozimek,
C. Radzewicz
Abstract:
We present a system of two independent strontium optical lattice standards probed with a single shared ultra-narrow laser. The absolute frequency of the clocks can be verified by the use of Er:fiber optical frequency comb with the GPS-disciplined Rb frequency standard. We report hertz-level spectroscopy of the clock line and measurements of frequency stability of the two strontium optical lattice…
▽ More
We present a system of two independent strontium optical lattice standards probed with a single shared ultra-narrow laser. The absolute frequency of the clocks can be verified by the use of Er:fiber optical frequency comb with the GPS-disciplined Rb frequency standard. We report hertz-level spectroscopy of the clock line and measurements of frequency stability of the two strontium optical lattice clocks.
△ Less
Submitted 15 June, 2015;
originally announced June 2015.