-
Kaonic lead feasibility measurement at DAΦNE to solve the charged kaon mass discrepancy
Authors:
D. Bosnar,
L. Abbene,
C. Amsler,
F. Artibani,
M. Bazzi,
M. Bragadireanu,
A. Buttacavoli,
M. Cargnelli,
M. Carminati,
A. Clozza,
F. Clozza,
G. Deda,
L. De Paolis,
R. Del Grande,
K. Dulski,
L. Fabbietti,
C. Fiorini,
I. Friščić,
C. Guaraldo,
M. Iliescu,
M. Iwasaki,
A. Khreptak,
M. Makek,
S. Manti,
J. Marton
, et al. (17 additional authors not shown)
Abstract:
An HPGe detector equipped with a transistor reset preamplifier and readout with a CAEN DT5781 fast pulse digitizer was employed in the measurement of X-rays from kaonic lead at the DA$Φ$NE $e^+e^-$ collider at the Laboratori Nazionali di Frascati of INFN. A thin scintillator in front of a lead target was used to select kaons im**ing on it and to form the trigger for the HPGe detector. We present…
▽ More
An HPGe detector equipped with a transistor reset preamplifier and readout with a CAEN DT5781 fast pulse digitizer was employed in the measurement of X-rays from kaonic lead at the DA$Φ$NE $e^+e^-$ collider at the Laboratori Nazionali di Frascati of INFN. A thin scintillator in front of a lead target was used to select kaons im**ing on it and to form the trigger for the HPGe detector. We present the results of the kaonic lead feasibility measurement, where we show that the resolution of the HPGe detector in regular beam conditions remains the same as that without the beam and that a satisfactory background reduction can be achieved. This measurement serves as a test bed for future dedicated kaonic X-rays measurements for the more precise determination of the charged kaon mass.
△ Less
Submitted 21 May, 2024;
originally announced May 2024.
-
Measurement of the mesonic decay branch of the $\bar{K}\!N\!N$ quasi-bound state
Authors:
T. Yamaga,
S. Ajimura,
H. Asano,
G. Beer,
H. Bhang,
M. Bragadireanu,
P. Buehler,
L. Busso,
M. Cargnelli,
S. Choi,
C. Curceanu,
S. Enomoto,
H. Fujioka,
Y. Fujiwara,
T. Fukuda,
C. Guaraldo,
T. Hashimoto,
R. S. Hayano,
T. Hiraiwa,
M. Iio,
M. Iliescu,
K. Inoue,
Y. Ishiguro,
T. Ishikawa,
S. Ishimoto
, et al. (45 additional authors not shown)
Abstract:
We conducted measurements of $K^- + {^3{\rm He}} \to π\!Y \!N + N'$ reactions using a $1~{\rm GeV}/c$ $K^-$-beam, with the objective of understanding the broad decay width of $\bar{K} \!N \!N$ (approximately twice as broad as that of $Λ(1405)$ considered to be the $\bar{K} \!N$ quasi-bound state). We successfully reproduced distributions of the $π\! Y \! N$ invariant mass and momentum transfer for…
▽ More
We conducted measurements of $K^- + {^3{\rm He}} \to π\!Y \!N + N'$ reactions using a $1~{\rm GeV}/c$ $K^-$-beam, with the objective of understanding the broad decay width of $\bar{K} \!N \!N$ (approximately twice as broad as that of $Λ(1405)$ considered to be the $\bar{K} \!N$ quasi-bound state). We successfully reproduced distributions of the $π\! Y \! N$ invariant mass and momentum transfer for $π\! Y \! N$ using model fitting functions for $\bar{K} \!N \!N$ formation and quasi-free $\bar{K}$ absorption (${\rm QF}_{\bar{K}-{\rm abs}}$) processes. The model can describe the experimental data quite well, and four $\bar{K} \! N \! N \to π\! Y \! N $ cross-sections were obtained. The results indicate that mesonic decay is the dominant decay branch of $\bar{K} \! N \! N$. The results also suggest that $Γ_{πΛN} \sim Γ_{πΣN}$, which indicates that the $I_{\bar{K} \! N}=1$ absorption channel, in addition to the $I_{\bar{K} \! N}=0$ absorption channel, substantially contribute to the $\bar{K} \! N \! N$ decay, making the $\bar{K} \! N \! N$ state approximately twice as unstable as $Λ$(1405).
△ Less
Submitted 2 June, 2024; v1 submitted 2 April, 2024;
originally announced April 2024.
-
Biophotons: A Hard Problem
Authors:
L. De Paolis,
R. Francini,
I. Davoli,
F. De Matteis,
A. Scordo,
A. Clozza,
M. Grandi,
E. Pace,
C. Curceanu,
P. Grigolini,
M. Benfatto
Abstract:
About a hundred years ago the Russian biologist A. Gurwitsch, based on his experiments with onion plants by measuring their growth rate, made the hypothesis that plants emitted a weak electromagnetic field which somehow influenced cell growth. This interesting observation remained fundamentally ignored by the scientific community and only in the 1950s the electromagnetic emission from some plants…
▽ More
About a hundred years ago the Russian biologist A. Gurwitsch, based on his experiments with onion plants by measuring their growth rate, made the hypothesis that plants emitted a weak electromagnetic field which somehow influenced cell growth. This interesting observation remained fundamentally ignored by the scientific community and only in the 1950s the electromagnetic emission from some plants was measured using a photomultiplier used in single counting mode. Later, in the 80s several groups in the world started some extensive work to understand the origin and role of this ultra-weak emission, hereby called biophotons, coming from living organisms. Biophotons are an endogenous very small production of photons in the visible energy range in and from cells and organism, and this emission is characteristic of alive organisms. Today there is no doubt that biophotons really exist, this emission has in fact been measured by many groups and on many different living organisms, from humans to bacteria. On the contrary, the origin of biophotons and whether organisms use them in some way to exchange information is not yet well known; no model proposed since now is really capable of reproducing and interpreting the great variety of experimental data coming from the many different living systems measured so far. In this brief review we present our experimental work on biophotons coming from germinating seeds, the main experimental results and some methods we are using to analyze the data in order to open the door for interpretative models of this phenomenon and clarifying its function in the regulation and communication between cells and living organisms. We also discuss some ideas on how to increase the signal-to-noise ratio of the measured signal to have new experimental possibilities that allow the measurement and the characterization of currently unmeasurable quantities.
△ Less
Submitted 30 January, 2024;
originally announced January 2024.
-
Discrete symmetries tested at 10$^{-4}$ precision using linear polarization of photons from positronium annihilations
Authors:
Paweł Moskal,
Eryk Czerwiński,
Juhi Raj,
Steven D. Bass,
Ermias Y. Beyene,
Neha Chug,
Aurélien Coussat,
Catalina Curceanu,
Meysam Dadgar,
Manish Das,
Kamil Dulski,
Aleksander Gajos,
Marek Gorgol,
Beatrix C. Hiesmayr,
Bożena Jasińska,
Krzysztof Kacprzak,
Tevfik Kaplanoglu,
Łukasz Kapłon,
Konrad Klimaszewski,
Paweł Konieczka,
Grzegorz Korcyl,
Tomasz Kozik,
Wojciech Krzemień,
Deepak Kumar,
Simbarashe Moyo
, et al. (16 additional authors not shown)
Abstract:
Discrete symmetries play an important role in particle physics with violation of CP connected to the matter-antimatter imbalance in the Universe. We report the most precise test of P, T and CP invariance in decays of ortho-positronium, performed with methodology involving polarization of photons from these decays. Positronium, the simplest bound state of an electron and positron, is of recent inte…
▽ More
Discrete symmetries play an important role in particle physics with violation of CP connected to the matter-antimatter imbalance in the Universe. We report the most precise test of P, T and CP invariance in decays of ortho-positronium, performed with methodology involving polarization of photons from these decays. Positronium, the simplest bound state of an electron and positron, is of recent interest with discrepancies reported between measured hyperfine energy structure and theory at the level of $10^{-4}$ signaling a need for better understanding of the positronium system at this level. We test discrete symmetries using photon polarizations determined via Compton scattering in the dedicated J-PET tomograph on an event-by-event basis and without the need to control the spin of the positronium with an external magnetic field, in contrast to previous experiments. Our result is consistent with QED expectations at the level of 0.0007 and one standard deviation.
△ Less
Submitted 22 January, 2024;
originally announced January 2024.
-
SIDDHARTA-2 apparatus for kaonic atoms research on the DA$Φ$NE collider
Authors:
F. Sirghi,
F. Sgaramella,
L. Abbene,
C. Amsler,
M. Bazzi,
G. Borghi,
D. Bosnar,
M. Bragadireanu,
A. Buttacavoli,
M. Carminati,
M. Cargnelli,
A. Clozza,
G. Deda,
L. De Paolis,
R. Del Grande,
K. Dulski,
L. Fabbietti,
C. Fiorini,
I. Friščić,
C. Guaraldo,
M. Iliescu,
M. Iwasaki,
A. Khreptak,
S. Manti,
J. Marton
, et al. (19 additional authors not shown)
Abstract:
SIDDHARTA-2 represents a state-of-the-art experiment designed to perform dedicated measurements of kaonic atoms, which are particular exotic atom configurations composed of a negatively charged kaon and a nucleus. Investigating these atoms provides an exceptional tool to comprehend the strong interactions in the non-perturbative regime involving strangeness. The experiment is installed at the DA…
▽ More
SIDDHARTA-2 represents a state-of-the-art experiment designed to perform dedicated measurements of kaonic atoms, which are particular exotic atom configurations composed of a negatively charged kaon and a nucleus. Investigating these atoms provides an exceptional tool to comprehend the strong interactions in the non-perturbative regime involving strangeness. The experiment is installed at the DA$Φ$NE electron-positron collider, of the INFN National Laboratory of Frascati (INFN-LNF) in Italy, aiming to perform the first-ever measurement of the 2p$\rightarrow$1s X-ray transitions in kaonic deuterium, a crucial step towards determining the isospin-dependent antikaon-nucleon scattering lengths. Based on the experience gained with the previous SIDDHARTA experiment, which performed the most precise measurement of the kaonic hydrogen 2p$\rightarrow$1s X-ray transitions, the present apparatus has been upgraded with innovative Silicon Drift Detectors (SDDs), distributed around a cryogenic gaseous target placed in a vacuum chamber at a short distance above the interaction region of the collider. We present a comprehensive description of the SIDDHARTA-2 setup including the optimization of its various components during the commissioning phase of the collider.
△ Less
Submitted 6 November, 2023;
originally announced November 2023.
-
First measurement of kaonic helium-4 M-series transitions
Authors:
F Sgaramella,
D Sirghi,
L Abbene,
F Artibani,
M Bazzi,
D Bosnar,
M Bragadireanu,
A Buttacavoli,
M Cargnelli,
M Carminati,
A Clozza,
F Clozza,
G Deda,
R Del Grande,
L De Paolis,
K Dulski,
L Fabbietti,
C Fiorini,
I Friscic,
C Guaraldo,
M Iliescu,
M Iwasaki,
A Khreptak,
S Manti,
J Marton
, et al. (18 additional authors not shown)
Abstract:
In this paper we present the results of a new kaonic helium-4 measurement with a 1.37 g/l gaseous target by the SIDDHARTA-2 experiment at the DAΦNE collider. We measured, for the first time, the energies and yields of three transitions belonging to the Mseries. Moreover, we improved by a factor about three, the statistical precision of the 2p level energy shift and width induced by the strong inte…
▽ More
In this paper we present the results of a new kaonic helium-4 measurement with a 1.37 g/l gaseous target by the SIDDHARTA-2 experiment at the DAΦNE collider. We measured, for the first time, the energies and yields of three transitions belonging to the Mseries. Moreover, we improved by a factor about three, the statistical precision of the 2p level energy shift and width induced by the strong interaction, obtaining the most precise measurement for gaseous kaonic helium, and measured the yield of the Lα transition at the employed density, providing a new experimental input to investigate the density dependence of kaonic atoms transitions yield.
△ Less
Submitted 31 October, 2023;
originally announced October 2023.
-
CdZnTe detectors tested at the DAΦNE collider for future kaonic atoms measurements
Authors:
A. Scordo,
L. Abbene,
F. Artibani,
M. Bazzi,
M. Bettelli,
D. Bosnar,
G. Borghi,
M. Bragadireanu,
A. Buttacavoli,
M. Cargnelli,
M. Carminati,
A. Clozza,
F. Clozza,
L. De Paolis,
G. Deda,
R. Del Grande,
L. Fabbietti,
C. Fiorini,
I. Friščić,
C. Guaraldo,
M. Iliescu,
M. Iwasaki,
A. Khreptak,
S. Manti,
J. Marton
, et al. (20 additional authors not shown)
Abstract:
The SIDDHARTA-2 collaboration at the INFN Laboratories of Frascati (LNF) aims to perform groundbreaking measurements on kaonic atoms. In parallel and beyond the ongoing kaonic deuterium, presently running on the DA$Φ$NE collider at LNF, we plan to install additional detectors to perform further kaonic atoms' studies, taking advantage of the unique low energy and low momentum spread $K^-$ beam deli…
▽ More
The SIDDHARTA-2 collaboration at the INFN Laboratories of Frascati (LNF) aims to perform groundbreaking measurements on kaonic atoms. In parallel and beyond the ongoing kaonic deuterium, presently running on the DA$Φ$NE collider at LNF, we plan to install additional detectors to perform further kaonic atoms' studies, taking advantage of the unique low energy and low momentum spread $K^-$ beam delivered by the at-rest decay of the $φ$ meson. CdZnTe devices are ideal for detecting transitions toward both the upper and lower levels of intermediate-mass kaonic atoms, like kaonic carbon and aluminium, which have an important impact on the strangeness sector of nuclear physics. We present the results obtained in a set of preliminary tests conducted on DA$Φ$NE, in view of measurements foreseen in 2024, with the twofold aim to tune the timing window required to reject the extremely high electromagnetic background, and to quantify the readout electronics saturation effect due to the high rate, when placed close to the Interaction Region (IR). In the first test we used commercial devices and electronics, while for the second one both were customized at the IMEM-CNR of Parma and the University of Palermo. The results confirmed the possibility of finding and matching a proper timing window where to identify the signal events and proved better performances, in terms of energy resolution, of the custom system. In both cases, strong saturation effects were confirmed, accounting for a loss of almost 90\% of the events, which will be overcome by a dedicated shielding structure foreseen for the final experimental setup.
△ Less
Submitted 23 October, 2023;
originally announced October 2023.
-
Detecting Iron Oxidation States in Liquids with the VOXES Bragg Spectrometer
Authors:
Simone Manti,
Marco Miliucci,
Alessandro Scordo,
Roberto Bedogni,
Alberto Clozza,
Mihail Iliescu,
Gabriel Moskal,
Kristian Piscicchia,
Alessio Porcelli,
Diana Sirghi,
Florin Sirghi,
Catalina Curceanu
Abstract:
Determining the oxidation states of metals assumes great importance in various applications because a variation in the oxidation number can drastically influence the material properties. As an example, this becomes evident in edible liquids like wine and oil, where a change in the oxidation states of the contained metals can significantly modify both the overall quality and taste. To this end, her…
▽ More
Determining the oxidation states of metals assumes great importance in various applications because a variation in the oxidation number can drastically influence the material properties. As an example, this becomes evident in edible liquids like wine and oil, where a change in the oxidation states of the contained metals can significantly modify both the overall quality and taste. To this end, here we present the MITIQO project, which aims to identify oxidation states of metals in edible liquids utilizing X-ray emission with Bragg spectroscopy. This is achieved using the VOXES crystal spectrometer, developed at INFN National Laboratories of Frascati (LNF), employing mosaic crystal (HAPG) in the Von Hamos configuration. This combination allow us to work with effective source sizes of up to a few millimeters and improves the typical low efficiency of Bragg spectroscopy, a crucial aspect when studying liquids with low metal concentration. Here we showcase the concept behind MITIQO, for a liquid solution containing oxidized iron. We performed several high-resolution emission spectra measurements, for the liquid and for different powdered samples containing oxidized and pure iron. By looking at the spectral features of the iron's K$β$ emission lineshape, we were able to obtain, for a liquid, a result consistent with the oxidized iron powders and successfully quantifying the effect of oxidation.
△ Less
Submitted 9 October, 2023;
originally announced October 2023.
-
Feasibility studies for imaging e$^{+}$e$^{-}$ annihilation with modular multi-strip detectors
Authors:
S. Sharma,
L. Povolo,
S. Mariazzi,
G. Korcyl,
K. Kacprzak,
D. Kumar,
S. Niedzwiecki,
J. Baran,
E. Beyene,
R. S. Brusa,
R. Caravita,
N. Chug,
A. Coussat,
C. Curceanu,
E. Czerwinski,
M. Dadgar,
M. Das,
K. Dulski,
K. Eliyan,
A. Gajos,
N. Gupta,
B. C. Hiesmayr,
L. Kaplon,
T. Kaplanoglu,
K. Klimaszewski
, et al. (19 additional authors not shown)
Abstract:
Studies based on imaging the annihilation of the electron (e$^{-}$) and its antiparticle positron (e$^{+}$) open up several interesting applications in nuclear medicine and fundamental research. The annihilation process involves both the direct conversion of e$^{+}$e$^{-}$ into photons and the formation of their atomically bound state, the positronium atom (Ps), which can be used as a probe for fu…
▽ More
Studies based on imaging the annihilation of the electron (e$^{-}$) and its antiparticle positron (e$^{+}$) open up several interesting applications in nuclear medicine and fundamental research. The annihilation process involves both the direct conversion of e$^{+}$e$^{-}$ into photons and the formation of their atomically bound state, the positronium atom (Ps), which can be used as a probe for fundamental studies. With the ability to produce large quantities of Ps, manipulate them in long-lived Ps states, and image their annihilations after a free fall or after passing through atomic interferometers, this purely leptonic antimatter system can be used to perform inertial sensing studies in view of a direct test of Einstein equivalence principle. It is envisioned that modular multistrip detectors can be exploited as potential detection units for this kind of studies. In this work, we report the results of the first feasibility study performed on a e$^{+}$ beamline using two detection modules to evaluate their reconstruction performance and spatial resolution for imaging e$^{+}$e$^{-}$ annihilations and thus their applicability for gravitational studies of Ps.
△ Less
Submitted 12 September, 2023;
originally announced September 2023.
-
Novel Machine Learning and Differentiable Programming Techniques applied to the VIP-2 Underground Experiment
Authors:
F Napolitano,
M Bazzi,
M Bragadireanu,
M Cargnelli,
A Clozza,
L De Paolis,
R Del Grande,
C Fiorini,
C Guaraldo,
M Iliescu,
M Laubenstein,
S Manti,
J Marton,
M Miliucci,
K Piscicchia,
A Porcelli,
A Scordo,
F Sgaramella,
D Sirghi,
F Sirghi,
O Doce,
J Zmeskal,
C Curceanu
Abstract:
In this work, we present novel Machine Learning and Differentiable Programming enhanced calibration techniques used to improve the energy resolution of the Silicon Drift Detectors (SDDs) of the VIP-2 underground experiment at the Gran Sasso National Laboratory (LNGS). We achieve for the first time a Full Width at Half Maximum (FWHM) in VIP-2 below 180 eV at 8 keV, improving around 10 eV on the pre…
▽ More
In this work, we present novel Machine Learning and Differentiable Programming enhanced calibration techniques used to improve the energy resolution of the Silicon Drift Detectors (SDDs) of the VIP-2 underground experiment at the Gran Sasso National Laboratory (LNGS). We achieve for the first time a Full Width at Half Maximum (FWHM) in VIP-2 below 180 eV at 8 keV, improving around 10 eV on the previous state-of-the-art. SDDs energy resolution is a key parameter in the VIP-2 experiment, which is dedicated to searches for physics beyond the standard quantum theory, targeting Pauli Exclusion Principle (PEP) violating atomic transitions. Additionally, we show that this method can correct for potential miscalibrations, requiring less fine-tuning with respect to standard methods.
△ Less
Submitted 26 May, 2023;
originally announced May 2023.
-
Biophotons -- new experimental data and analysis
Authors:
M. Benfatto,
E. Pace,
I. Davoli,
Massimiliano Lucci,
R. Francini,
Fabio De Matteis,
Alessandro Scordo,
Alberto Clozza,
Maurizio Grandi,
C. Curceanu,
P. Grigolini
Abstract:
Biophotons are an ultra-weak emission of photons in the visible energy range from living matter. In this work, we study the emission from germinating seeds using an experimental technique designed to detect light of extremely small intensity. The emission from lentil seeds and single bean was analyzed during the whole germination process in terms of both the different spectral components through l…
▽ More
Biophotons are an ultra-weak emission of photons in the visible energy range from living matter. In this work, we study the emission from germinating seeds using an experimental technique designed to detect light of extremely small intensity. The emission from lentil seeds and single bean was analyzed during the whole germination process in terms of both the different spectral components through low pass filters and the different count distributions in the various stages of the germination process. Although the shape of the emission spectrum appears to be very similar in the two samples used in our experiment, our analysis is able to highlight the differences present in the two cases. In this way, it was possible to correlate the various types of emissions to the degree of development of the seed during germination.
△ Less
Submitted 16 May, 2023;
originally announced May 2023.
-
Measurements of high-n transitions in intermediate mass kaonic atoms by SIDDHARTA-2 at DA$\mathrmΦ$NE
Authors:
F. Sgaramella,
M. Tüchler,
C. Amsler,
M. Bazzi,
D. Bosnar,
M. Bragadireanu,
M. Cargnelli,
M. Carminati,
A. Clozza,
G. Deda,
R. Del Grande,
L. De Paolis,
L. Fabbietti,
C. Fiorini,
I. Friščić,
C. Guaraldo,
M. Iliescu,
M. Iwasaki,
A. Khreptak,
S. Manti,
J. Marton,
M. Miliucci,
P. Moskal,
F. Napolitano,
S. Niedźwiecki
, et al. (16 additional authors not shown)
Abstract:
The SIDDHARTA-2 experiment installed at the DA$\mathrmΦ$NE collider of INFN-LNF performed, for the first time, measurements of high-n transitions in intermediate mass kaonic atoms during the data taking campaigns of 2021 and 2022. Kaonic carbon, oxygen, nitrogen and aluminium transitions, which occur in the setup materials, were measured by using the kaons stopped in the gaseous helium target cell…
▽ More
The SIDDHARTA-2 experiment installed at the DA$\mathrmΦ$NE collider of INFN-LNF performed, for the first time, measurements of high-n transitions in intermediate mass kaonic atoms during the data taking campaigns of 2021 and 2022. Kaonic carbon, oxygen, nitrogen and aluminium transitions, which occur in the setup materials, were measured by using the kaons stopped in the gaseous helium target cell with aluminium frames and Kapton walls, and are reported in this paper. These new kaonic atoms measurements add valuable input to the kaonic atoms transitions data base, which is used as a reference for theories and models of the low-energy strong interaction between antikaon and nuclei. Moreover, these results pave the way for future dedicated kaonic atoms measurements through the whole periodic table and to a new era for the antikaon-nuclei studies at low energy.
△ Less
Submitted 22 April, 2023;
originally announced April 2023.
-
Comparative studies of the sensitivities of sparse and full geometries of Total-Body PET scanners built from crystals and plastic scintillators
Authors:
Meysam Dadgar,
Szymon Parzych,
Jakub Baran,
Neha Chug,
Catalina Curceanu,
Eryk Czerwiński,
Kamil Dulski,
Kavya Elyan,
Aleksander Gajos,
Beatrix Hiesmayr,
Łukasz Kapłon,
Konrad Klimaszewski,
Paweł Konieczka,
Grzegorz Korcyl,
Tomasz Kozik,
Wojciech Krzemień,
Deepak Kumar,
Szymon Niedźwiecki,
Domonik Panek,
Eleną Perez del Rio,
Lech Raczyński,
Sushil Sharma,
Shivani,
Roman Shopa,
Magdalena Skurzok
, et al. (6 additional authors not shown)
Abstract:
Background: Total-Body imaging offers high sensitivity, single-bed position, and low dose, but high construction costs limit worldwide utilization. This study compares existing and develo** tomographs using plastic scintillators via simulations to propose a cost-efficient Total-Body PET scanner.
Methods: Simulations of eight uEXPLORER tomographs with different scintillator materials, axial fie…
▽ More
Background: Total-Body imaging offers high sensitivity, single-bed position, and low dose, but high construction costs limit worldwide utilization. This study compares existing and develo** tomographs using plastic scintillators via simulations to propose a cost-efficient Total-Body PET scanner.
Methods: Simulations of eight uEXPLORER tomographs with different scintillator materials, axial field-of-view, and detector configuration, and eight J-PET scanners with various field-of-view, plastic scintillator cross-sections, and layers were performed. Biograph Vision was also simulated. Two types of simulations were conducted with a central source and a water-filled phantom.
Results: BGO crystal-based scanners showed the best sensitivity (350 cps/kBq at the center). Sparse geometry or LYSO crystals reduced sensitivity. J-PET design showed similar sensitivity to sparse LYSO detectors, with full body coverage and additional gain for brain imaging.
Conclusion: The J-PET tomography system using plastic scintillators could be a cost-efficient alternative for Total-Body PET scanners, overcoming high construction costs while maintaining sensitivity
△ Less
Submitted 12 April, 2023;
originally announced April 2023.
-
A Time Projection Chamber to Search for Feebly Interacting Bosons via Proton Induced Nuclear Reactions
Authors:
Martin Sevior,
Michael Baker,
Lindsey Bignell,
Catalina Curceanu,
Jackson T. H. Dowie,
Tibor Kibedi,
David Jamieson,
Andrew Stuchbery,
Andrea Thamm,
Martin White
Abstract:
We propose a new Time Projection Chamber particle detector (TPC) to search for the existence of feebly-interacting bosons and to investigate the existence of the X17 boson, proposed by the ATOMKI group to explain anomalous results in the angular distributions of electron-positron pairs created in proton-induced nuclear reactions. Our design will provide 200 times greater sensitivity than ATOMKI an…
▽ More
We propose a new Time Projection Chamber particle detector (TPC) to search for the existence of feebly-interacting bosons and to investigate the existence of the X17 boson, proposed by the ATOMKI group to explain anomalous results in the angular distributions of electron-positron pairs created in proton-induced nuclear reactions. Our design will provide 200 times greater sensitivity than ATOMKI and the program of research will also provide world-leading limits on feebly interacting bosons in the mass range of 5 - 25 MeV.
△ Less
Submitted 26 February, 2023;
originally announced February 2023.
-
Precise lifetime measurement of $^4_Λ$H hypernucleus using in-flight $^4$He$(K^-, π^0)^4_Λ$H reaction
Authors:
T. Akaishi,
H. Asano,
X. Chen,
A. Clozza,
C. Curceanu,
R. Del Grande,
C. Guaraldo,
C. Han,
T. Hashimoto,
M. Iliescu,
K. Inoue,
S. Ishimoto,
K. Itahashi,
M. Iwasaki,
Y. Ma,
M. Miliucci,
R. Murayama,
H. Noumi,
H. Ohnishi,
S. Okada,
H. Outa,
K. Piscicchia,
A. Sakaguchi,
F. Sakuma,
M. Sato
, et al. (13 additional authors not shown)
Abstract:
We present a new measurement of the $^4_Λ$H hypernuclear lifetime using in-flight $K^-$ + $^4$He $\rightarrow$ $^4_Λ$H + $π^0$ reaction at the J-PARC hadron facility. We demonstrate, for the first time, the effective selection of the hypernuclear bound state using only the $γ$-ray energy decayed from $π^0$. This opens the possibility for a systematic study of isospin partner hypernuclei through co…
▽ More
We present a new measurement of the $^4_Λ$H hypernuclear lifetime using in-flight $K^-$ + $^4$He $\rightarrow$ $^4_Λ$H + $π^0$ reaction at the J-PARC hadron facility. We demonstrate, for the first time, the effective selection of the hypernuclear bound state using only the $γ$-ray energy decayed from $π^0$. This opens the possibility for a systematic study of isospin partner hypernuclei through comparison with data from ($K^-$, $π^-$) reaction. As the first application of this method, our result for the $^4_Λ$H lifetime, $τ(^4_Λ\mathrm{H}) = 206 \pm 8 (\mathrm{stat.}) \pm 12 (\mathrm{syst.})\ \mathrm{ps}$, is one of the most precise measurements to date. We are also preparing to measure the lifetime of the hypertriton ($^3_Λ$H) using the same setup in the near future.
△ Less
Submitted 27 August, 2023; v1 submitted 14 February, 2023;
originally announced February 2023.
-
TOF MLEM Adaptation for the Total-Body J-PET with a Realistic Analytical System Response Matrix
Authors:
R. Y. Shopa,
J. Baran,
K. Klimaszewski,
W. Krzemień,
L. Raczyński,
W. Wiślicki,
K. Brzeziński,
N. Chug,
A. Coussat,
C. Curceanu,
E. Czerwiński,
M. Dadgar,
K. Dulski,
J. Gajewski,
A. Gajos,
B. C. Hiesmayr,
E. Kavya Valsan,
G. Korcyl,
T. Kozik,
D. Kumar,
Ł. Kapłon,
G. Moskal,
S. Niedźwiecki,
D. Panek,
S. Parzych
, et al. (10 additional authors not shown)
Abstract:
We report a study of the original image reconstruction algorithm based on the time-of-flight maximum likelihood expectation maximisation (TOF MLEM), developed for the total-body (TB) Jagiellonian PET (J-PET) scanners. The method is applicable to generic cylindrical or modular multi-layer layouts and is extendable to multi-photon imaging. The system response matrix (SRM) is represented as a set of…
▽ More
We report a study of the original image reconstruction algorithm based on the time-of-flight maximum likelihood expectation maximisation (TOF MLEM), developed for the total-body (TB) Jagiellonian PET (J-PET) scanners. The method is applicable to generic cylindrical or modular multi-layer layouts and is extendable to multi-photon imaging. The system response matrix (SRM) is represented as a set of analytical functions, uniquely defined for each pair of plastic scintillator strips used for the detection. A realistic resolution model (RM) in detector space is derived from fitting the Monte Carlo simulated emissions and detections of annihilation photons on oblique transverse planes. Additional kernels embedded in SRM account for TOF, parallax effect and axial smearing. The algorithm was tested on datasets, simulated in GATE for the NEMA IEC and static XCAT phantoms inside a 24-module 2-layer TB J-PET. Compared to the reference TOF MLEM with none or a shift-invariant RM, an improvement was observed, as evaluated by the analysis of image quality, difference images and ground truth metrics. We also reconstructed the data with additive contributions, pre-filtered geometrically and with non-TOF scatter correction applied. Despite some deterioration, the obtained results still capitalise on the realistic RM with better edge preservation and superior ground truth metrics. The envisioned prospects of the TOF MLEM with analytical SRM include its application in multi-photon imaging and further upgrade to account for the non-collinearity, positron range and other factors.
△ Less
Submitted 4 May, 2023; v1 submitted 6 February, 2023;
originally announced February 2023.
-
New opportunities for kaonic atoms measurements from CdZnTe detectors
Authors:
L. Abbene,
M. Bettelli,
A. Buttacavoli,
F. Principato,
A. Zappettini,
C. Amsler,
M. Bazzi,
D. Bosnar,
M. Bragadireanu,
M. Cargnelli,
M. Carminati,
A. Clozza,
G. Deda,
L. De Paolis,
R. Del Grande,
L. Fabbietti,
C. Fiorini,
I. Friščić,
C. Guaraldo,
M. Iliescu,
M. Iwasaki,
A. Khreptak,
S. Manti,
J. Marton,
M. Miliucci
, et al. (20 additional authors not shown)
Abstract:
We present the tests performed by the SIDDHARTA-2 collaboration at the DAΦNE collider with a quasi-hemispherical CdZnTe detector. The very good room-temperature energy resolution and efficiency in a wide energy range show that this detector technology is ideal for studying radiative transitions in intermediate and heavy-mass kaonic atoms. The CdZnTe detector was installed for the first time in an…
▽ More
We present the tests performed by the SIDDHARTA-2 collaboration at the DAΦNE collider with a quasi-hemispherical CdZnTe detector. The very good room-temperature energy resolution and efficiency in a wide energy range show that this detector technology is ideal for studying radiative transitions in intermediate and heavy-mass kaonic atoms. The CdZnTe detector was installed for the first time in an accelerator environment to perform tests on the background rejection capabilities, which were achieved by exploiting the SIDDHARTA-2 Luminosity Monitor. A spectrum with an $^{241}Am$ source has been acquired, with beams circulating in the main rings, and peak resolutions of 6% at 60 keV and of 2.2% at 511 keV have been achieved. The background suppression factor, which turned out to be of the order of $\simeq10^{5-6}$, opens the possibility to plan for future kaonic atom measurements with CdZnTe detectors.
△ Less
Submitted 28 January, 2023;
originally announced January 2023.
-
Cancellation effects as a fingerprint of quantum collapse models at atomic scale
Authors:
Kristian Piscicchia,
Sandro Donadi,
Simone Manti,
Angelo Bassi,
Maaneli Derakhshani,
Lajos Diosi,
Catalina Curceanu
Abstract:
In this work the spontaneous electromagnetic radiation from atomic systems, induced by dynamical wave-function collapse, is investigated in the X-rays domain. Strong departures are evidenced with respect to the simple cases considered until now in the literature, in which the emission is either perfectly coherent (protons in the same nuclei) or incoherent (electrons). In this low-energy regime the…
▽ More
In this work the spontaneous electromagnetic radiation from atomic systems, induced by dynamical wave-function collapse, is investigated in the X-rays domain. Strong departures are evidenced with respect to the simple cases considered until now in the literature, in which the emission is either perfectly coherent (protons in the same nuclei) or incoherent (electrons). In this low-energy regime the spontaneous radiation rate strongly depends on the atomic species under investigation and, for the first time, is found to depend on the specific collapse model.
△ Less
Submitted 23 November, 2023; v1 submitted 24 January, 2023;
originally announced January 2023.
-
On the linear friction many-body equation for dissipative spontaneous wavefunction collapse
Authors:
Giovanni Di Bartolomeo,
Matteo Carlesso,
Kristian Piscicchia,
Catalina Curceanu,
Maaneli Derakhshani,
Lajos Diósi
Abstract:
We construct and study the simplest universal dissipative Lindblad master equation for many-body systems with the purpose of a new dissipative extension of existing nonrelativistic theories of fundamental spontaneous decoherence and spontaneous wave function collapse in nature. It is universal as it is written in terms of second-quantized mass density $\hat ρ$ and current $\hat J$, thus making it…
▽ More
We construct and study the simplest universal dissipative Lindblad master equation for many-body systems with the purpose of a new dissipative extension of existing nonrelativistic theories of fundamental spontaneous decoherence and spontaneous wave function collapse in nature. It is universal as it is written in terms of second-quantized mass density $\hat ρ$ and current $\hat J$, thus making it independent of the material structure and its parameters. Assuming linear friction in the current, we find that the dissipative structure is strictly constrained. Following the general structure of our dissipative Lindblad equation, we derive and analyze the dissipative extensions of the two most known spontaneous wave function collapse models, the Diósi-Penrose and the continuous spontaneous localization models.
△ Less
Submitted 6 July, 2023; v1 submitted 18 January, 2023;
originally announced January 2023.
-
Hadron Production and Propagation in Pion-Induced Reactions on Nuclei
Authors:
R. Abou Yassine,
J. Adamczewski-Musch,
O. Arnold,
E. T. Atomssa,
M. Becker,
C. Behnke,
J. C. Berger-Chen,
A. Blanco,
C. Blume,
M. Böhmer,
L. Chlad,
P. Chudoba,
I. Ciepał,
C. Deveaux,
D. Dittert,
J. Dreyer,
E. Epple,
L. Fabbietti,
P. Fonte,
C. Franco,
J. Friese,
I. Fröhlich,
J. Förtsc,
T. Galatyuk,
J. A. Garzón
, et al. (103 additional authors not shown)
Abstract:
Hadron production ($π^\pm$, proton, $Λ$, $K_S^0$, $K^\pm$) in $π^- + \mathrm{C}$ and $π^- + \mathrm{W}$ collisions is investigated at an incident pion beam momentum of $1.7~\mathrm{GeV}/c$. This comprehensive set of data measured with HADES at SIS18/GSI significantly extends the existing world data on hadron production in pion induced reactions and provides a new reference for models that are comm…
▽ More
Hadron production ($π^\pm$, proton, $Λ$, $K_S^0$, $K^\pm$) in $π^- + \mathrm{C}$ and $π^- + \mathrm{W}$ collisions is investigated at an incident pion beam momentum of $1.7~\mathrm{GeV}/c$. This comprehensive set of data measured with HADES at SIS18/GSI significantly extends the existing world data on hadron production in pion induced reactions and provides a new reference for models that are commonly used for the interpretation of heavy-ion collisions. The measured inclusive differential production cross-sections are compared with state-of-the-art transport model (GiBUU, SMASH) calculations. The (semi-) exclusive channel $π^- + A \rightarrow Λ+ K_S^0 +X$, in which the kinematics of the strange hadrons are correlated, is also investigated and compared to a model calculation. Agreement and remaining tensions between data and the current version of the considered transport models are discussed.
△ Less
Submitted 17 February, 2023; v1 submitted 10 January, 2023;
originally announced January 2023.
-
J-PET detection modules based on plastic scintillators for performing studies with positron and positronium beams
Authors:
S. Sharma,
J. Baran,
R. S. Brusa,
R. Caravita,
N. Chug,
A. Coussat,
C. Curceanu,
E. Czerwinski,
M. Dadgar,
K. Dulski,
K. Eliyan,
A. Gajos,
B. C. Hiesmayr,
K. Kacprzak,
L. Kaplon,
K. Klimaszewski,
P. Konieczka,
G. Korcyl,
T. Kozik,
W. Krzemien,
D. Kumar,
S. Mariazzi,
S. Niedzwiecki,
L. Panasa,
S. Parzych
, et al. (11 additional authors not shown)
Abstract:
The J-PET detector, which consists of inexpensive plastic scintillators, has demonstrated its potential in the study of fundamental physics. In recent years, a prototype with 192 plastic scintillators arranged in 3 layers has been optimized for the study of positronium decays. This allows performing precision tests of discrete symmetries (C, P, T) in the decays of positronium atoms. Moreover, than…
▽ More
The J-PET detector, which consists of inexpensive plastic scintillators, has demonstrated its potential in the study of fundamental physics. In recent years, a prototype with 192 plastic scintillators arranged in 3 layers has been optimized for the study of positronium decays. This allows performing precision tests of discrete symmetries (C, P, T) in the decays of positronium atoms. Moreover, thanks to the possibility of measuring the polarization direction of the photon based on Compton scattering, the predicted entanglement between the linear polarization of annihilation photons in positronium decays can also be studied. Recently, a new J-PET prototype was commissioned, based on a modular design of detection units. Each module consists of 13 plastic scintillators and can be used as a stand-alone, compact and portable detection unit. In this paper, the main features of the J-PET detector, the modular prototype and their applications for possible studies with positron and positronium beams are discussed. Preliminary results of the first test experiment performed on two detection units in the continuous positron beam recently developed at the Antimatter Laboratory (AML) of Trento are also reported.
△ Less
Submitted 7 January, 2023;
originally announced January 2023.
-
Experimental test of Non-Commutative Quantum Gravity by VIP-2 Lead
Authors:
Kristian Piscicchia,
Andrea Addazi,
Antonino Marciano,
Massimiliano Bazzi,
Michael Cargnelli,
Alberto Clozza,
Luca De Paolis,
Raffaele Del Grande,
Carlo Guaraldo,
Mihail Antoniu Iliescu,
Matthias Laubenstein,
Johann Marton,
Marco Miliucci,
Fabrizio Napolitano,
Alessio Porcelli,
Alessandro Scordo,
Diana Laura Sirghi,
Florin Sirghi,
Oton Vazquez Doce,
Johann Zmeskal,
Catalina Curceanu
Abstract:
Pauli Exclusion Principle (PEP) violations induced by space-time non-commutativity, a class of universality for several models of Quantum Gravity, are investigated by the VIP-2 Lead experiment at the Gran Sasso underground National Laboratory of INFN. The VIP-2 Lead experimental bound on the non-commutative space-time scale $Λ$ excludes $θ$-Poincaré far above the Planck scale for non vanishing ``e…
▽ More
Pauli Exclusion Principle (PEP) violations induced by space-time non-commutativity, a class of universality for several models of Quantum Gravity, are investigated by the VIP-2 Lead experiment at the Gran Sasso underground National Laboratory of INFN. The VIP-2 Lead experimental bound on the non-commutative space-time scale $Λ$ excludes $θ$-Poincaré far above the Planck scale for non vanishing ``electric-like" components of $θ_{μν}$, and up to $6.9 \cdot 10^{-2}$ Planck scales if they are null. Therefore, this new bound represents the tightest one so far provided by atomic transitions tests. This result strongly motivates high sensitivity underground X-ray measurements as critical tests of Quantum Gravity and of the very microscopic space-time structure.
△ Less
Submitted 9 December, 2022;
originally announced December 2022.
-
Realistic Total-Body J-PET Geometry Optimization -- Monte Carlo Study
Authors:
Jakub Baran,
Wojciech Krzemien,
Lech Raczyński,
Mateusz Bała,
Aurelien Coussat,
Szymon Parzych,
Neha Chug,
Eryk Czerwiński,
Catalina Oana Curceanu,
Meysam Dadgar,
Kamil Dulski,
Kavya Eliyan,
Jan Gajewski,
Aleksander Gajos,
Beatrix Hiesmayr,
Krzysztof Kacprzak,
Łukasz Kapłon,
Konrad Klimaszewski,
Grzegorz Korcyl,
Tomasz Kozik,
Deepak Kumar,
Szymon Niedźwiecki,
Dominik Panek,
Elena Perez del Rio,
Antoni Ruciński
, et al. (9 additional authors not shown)
Abstract:
Total-Body PET is one of the most promising medical diagnostics modalities. The high sensitivity provided by Total-Body technology can be advantageous for novel tomography methods like positronium imaging. Several efforts are ongoing to lower the price of the TB-PET systems. Among the alternatives, the Jagiellonian PET (J-PET) technology, based on plastic scintillator strips, offers a low-cost alt…
▽ More
Total-Body PET is one of the most promising medical diagnostics modalities. The high sensitivity provided by Total-Body technology can be advantageous for novel tomography methods like positronium imaging. Several efforts are ongoing to lower the price of the TB-PET systems. Among the alternatives, the Jagiellonian PET (J-PET) technology, based on plastic scintillator strips, offers a low-cost alternative. The work aimed to compare five Total-Body J-PET geometries as a possible next generation J-PET scanner design. We present comparative studies of performance characteristics of the cost-effective Total-Body PET scanners using J-PET technology. We investigated in silico five Total-Body scanner geometries. Monte Carlo simulations of the XCAT phantom, the 2-meter sensitivity line source and positronium sensitivity phantoms were performed. We compared the sensitivity profiles for 2-gamma and 3-gamma tomography, relative cost of the setups and performed quantitative analysis of the reconstructed images. The analysis of the reconstructed XCAT images reveals the superiority of the seven-ring scanners over the three-ring setups. However, the three-ring scanners would be approximately 2-3 times cheaper. The peak sensitivity values for two-gamma vary from 20 to 34 cps/kBq. The sensitivity curves for the positronium tomography have a similar shape to the two-gamma sensitivity profiles. The peak values are lower compared to the two-gamma cases, from about 20-28 times, with a maximum of 1.66 cps/kBq. The results show the feasibility of multi-organ imaging of all the systems to be considered for the next generation of TB J-PET designs. The relative cost for all the scanners is about 10-4 times lower compared to the cost of the uExplorer. These properties coupled together with J-PET cost-effectiveness, make the J-PET technology an attractive solution for broad application in clinics.
△ Less
Submitted 16 February, 2024; v1 submitted 5 December, 2022;
originally announced December 2022.
-
First Simultaneous K$^-$p $\rightarrow (Σ^0/Λ) \, π^0$ Cross Sections Measurements at 98 MeV/c
Authors:
Kristian Piscicchia,
Magdalena Skurzok,
Michael Cargnelli,
Raffaele Del Grande,
Laura Fabbietti,
Johann Marton,
Pawel Moskal,
Alessandro Scordo,
Àngels Ramos,
Diana Laura Sirghi,
Oton Vazquez Doce,
Johann Zmeskal,
Slawomir Wycech,
Paolo Branchini,
Filippo Ceradini,
Eryk Czerwinski,
Erika De Lucia,
Salvatore Fiore,
Andrzej Kupsc,
Giuseppe Mandaglio,
Matteo Martini,
Antonio Passeri,
Vincenzo Patera,
Elena Perez Del Rio,
Andrea Selce
, et al. (2 additional authors not shown)
Abstract:
We report the first simultaneous and independent measurements of the K$^{-}$p $\rightarrow Σ^0 \, π^{0}$ and K$^{-}$p $\rightarrow Λ\, π^{0}$ cross sections around 100 MeV/c kaon momentum. The kaon beam delivered by the DA$Φ$NE collider was exploited to detect K$^-$ absorptions on Hydrogen atoms, populating the gas mixture of the KLOE drift chamber. The precision of the measurements (…
▽ More
We report the first simultaneous and independent measurements of the K$^{-}$p $\rightarrow Σ^0 \, π^{0}$ and K$^{-}$p $\rightarrow Λ\, π^{0}$ cross sections around 100 MeV/c kaon momentum. The kaon beam delivered by the DA$Φ$NE collider was exploited to detect K$^-$ absorptions on Hydrogen atoms, populating the gas mixture of the KLOE drift chamber. The precision of the measurements ($σ_{K^- p \rightarrow Σ^0 π^0} = 42.8 \pm 1.5 (stat.) ^{+2.4}_{-2.0}(syst.) \ \mathrm{mb}$ and $σ_{K^- p \rightarrow Λπ^0} = 31.0 \pm 0.5 (stat.) ^{+1.2}_{-1.2}(syst.) \ \mathrm{mb}\,$) is the highest yet obtained in the low kaon momentum regime.
△ Less
Submitted 20 October, 2022; v1 submitted 19 October, 2022;
originally announced October 2022.
-
Snowmass 2021 Topical Report on Synergies in Research at Underground Facilities
Authors:
Catalina Curceanu,
Derek Elsworth,
Joe Formaggio,
Jan Harms,
Daniel Robertson,
William Roggenthen,
Herb Wang,
Sijbrand de Jong,
John L. Orrell
Abstract:
This is a Snowmass 2021 Topical Report for the Underground Facilities and Infrastructure Frontier on Synergies in Research at Underground Facilities: A broad range of scientific and engineering research is possible in underground laboratories, beyond the physics-focused activities described in the other Underground Facilities and Infrastructure Topical Reports. These areas of research include nucl…
▽ More
This is a Snowmass 2021 Topical Report for the Underground Facilities and Infrastructure Frontier on Synergies in Research at Underground Facilities: A broad range of scientific and engineering research is possible in underground laboratories, beyond the physics-focused activities described in the other Underground Facilities and Infrastructure Topical Reports. These areas of research include nuclear astrophysics, geology, geoengineering, gravitational wave detection, biology, and perhaps soon quantum information science. This UF Topical Report will survey those other scientific and engineering research activities that share interest in research-orientated Underground Facilities and Infrastructure. In most cases the breadth and depth of research aims is too large to cover in completeness and references to surveys or key documents for those fields are provided after introductory summaries. Additional attention is then given to shared, similar, and unique needs of each research area with respect to the broader underground research community's Underground Facilities and Infrastructure needs. Where potential conflicts of usage type, site, or duration might arise, these are identified.
△ Less
Submitted 6 October, 2022;
originally announced October 2022.
-
Pole position of $Λ(1405)$ measured in $d(K^-,n)πΣ$ reactions
Authors:
J-PARC E31 Collaboration,
:,
S. Aikawa,
S. Ajimura,
T. Akaishi,
H. Asano,
G. Beer,
C. Berucci,
M. Bragadireanu,
P. Buehler,
L. Busso,
M. Cargnelli,
S. Choi,
C. Curceanu,
S. Enomoto,
H. Fujioka,
Y. Fujiwara,
T. Fukuda,
C. Guaraldo,
T. Hashimoto,
R. S. Hayano,
T. Hiraiwa,
M. Iio,
M. Iliescu,
K. Inoue
, et al. (53 additional authors not shown)
Abstract:
We measured a set of $π^\pmΣ^\mp$, $π^0Σ^0$, and $π^-Σ^0$ invariant mass spectra below and above the $\bar{K}N$ mass threshold in $K^-$-induced reactions on deuteron. We deduced the $S$-wave $\bar{K}N\rightarrowπΣ$ and $\bar{K}N\rightarrow\bar{K}N$ scattering amplitudes in the isospin 0 channel in the framework of a $\bar{K}N$ and $πΣ$ coupled channel. We find that a resonance pole corresponding t…
▽ More
We measured a set of $π^\pmΣ^\mp$, $π^0Σ^0$, and $π^-Σ^0$ invariant mass spectra below and above the $\bar{K}N$ mass threshold in $K^-$-induced reactions on deuteron. We deduced the $S$-wave $\bar{K}N\rightarrowπΣ$ and $\bar{K}N\rightarrow\bar{K}N$ scattering amplitudes in the isospin 0 channel in the framework of a $\bar{K}N$ and $πΣ$ coupled channel. We find that a resonance pole corresponding to $Λ(1405)$ is located at 1417.7$^{+6.0}_{-7.4}$(fitting errors)$^{+1.1}_{-1.0}$(systematic errors) + $[-26.1^{+6.0}_{-7.9}$(fitting errors)$^{+1.7}_{-2.0}$(systematic errors)]$i$ MeV/$c^2$, closer to the $\bar{K}N$ mass threshold than the value determined by the Particle Data Group.
△ Less
Submitted 17 September, 2022;
originally announced September 2022.
-
Strongest atomic physics bounds on Non-Commutative Quantum Gravity Models
Authors:
Kristian Piscicchia,
Andrea Addazi,
Antonino Marciano,
Massimiliano Bazzi,
Michael Cargnelli,
Alberto Clozza,
Luca De Paolis,
Raffaele Del Grande,
Carlo Guaraldo,
Mihail Antoniu Iliescu,
Matthias Laubenstein,
Johann Marton,
Marco Miliucci,
Fabrizio Napolitano,
Alessio Porcelli,
Alessandro Scordo,
Diana Laura Sirghi,
Florin Sirghi,
Oton Vazquez Doce,
Johann Zmeskal,
Catalina Curceanu
Abstract:
Investigations of possible violations of the Pauli Exclusion Principle represent critical tests of the microscopic space-time structure and properties. Space-time non-commutativity provides a class of universality for several Quantum Gravity models. In this context the VIP-2 Lead experiment sets the strongest bounds, searching for Pauli Exclusion Principle violating atomic-transitions in lead, exc…
▽ More
Investigations of possible violations of the Pauli Exclusion Principle represent critical tests of the microscopic space-time structure and properties. Space-time non-commutativity provides a class of universality for several Quantum Gravity models. In this context the VIP-2 Lead experiment sets the strongest bounds, searching for Pauli Exclusion Principle violating atomic-transitions in lead, excluding the $θ$-Poincaré Non Commutative Quantum Gravity models far above the Planck scale for non-vanishing $θ_{μν}$ ``electric-like'' components, and up to $6.9 \cdot 10^{-2}$ Planck scales if $θ_{0i} = 0$.
△ Less
Submitted 31 August, 2022;
originally announced September 2022.
-
Studies of the linearity and stability of Silicon Drift Detectors for kaonic atoms X-ray spectroscopy
Authors:
A. Khreptak,
C. Amsler,
M. Bazzi,
D. Bosnar,
M. Bragadireanu,
M. Carminati,
M. Cargnelli,
A. Clozza,
G. Deda,
L. De Paolis,
R. Del Grande,
L. Fabbietti,
C. Fiorini,
C. Guaraldo,
M. Iliescu,
M. Iwasaki,
S. Manti,
J. Marton,
M. Miliucci,
P. Moskal,
F. Napolitano,
S. Niedźwiecki,
H. Ohnishi,
K. Piscicchia,
Y. Sada
, et al. (14 additional authors not shown)
Abstract:
The SIDDHARTA-2 experiment at the DA$Φ$NE collider aims to perform precision measurements of kaonic atoms X-ray spectroscopy for the investigation of the antikaon-nucleon strong interaction. To achieve this goal, novel large-area Silicon Drift Detectors (SDDs) have been developed. These devices have special geometry, field configuration and readout electronics that ensure excellent performance in…
▽ More
The SIDDHARTA-2 experiment at the DA$Φ$NE collider aims to perform precision measurements of kaonic atoms X-ray spectroscopy for the investigation of the antikaon-nucleon strong interaction. To achieve this goal, novel large-area Silicon Drift Detectors (SDDs) have been developed. These devices have special geometry, field configuration and readout electronics that ensure excellent performance in terms of linearity and stability. The paper presents preliminary results for the linearity determination and stability monitoring of the SDDs system during the measurement of kaonic deuterium carried out in the summer of 2022.
△ Less
Submitted 31 August, 2022;
originally announced August 2022.
-
First tests of the full SIDDHARTA-2 experimental apparatus with a 4 He gaseous target
Authors:
A. Scordo,
C. Amsler,
M. Bazzi,
D. Bosnar,
M. Bragadireanu,
M. Cargnelli,
M. Carminati,
A. Clozza,
G. Deda,
L. De Paolis,
R. Del Grande,
L. Fabbietti,
C. Fiorini,
C. Guaraldo,
M. Iliescu,
M. Iwasaki,
A. Khreptak,
P. King,
P. Levi Sandri,
S. Manti,
J. Marton,
M. Miliucci,
P. Moskal,
F. Napolitano,
S. Niedźwiecki
, et al. (16 additional authors not shown)
Abstract:
In this paper, we present the first tests performed after the full installation of the SIDDHARTA-2 experimental apparatus on the Interaction Region of the DAΦNE collider at the INFN National Laboratories of Frascati. Before starting the first measurement of the kaonic deuterium 2p{\rightarrow}1s transition, accurate evaluation of the background rejection. mainly achieved with the Kaon Trigger syst…
▽ More
In this paper, we present the first tests performed after the full installation of the SIDDHARTA-2 experimental apparatus on the Interaction Region of the DAΦNE collider at the INFN National Laboratories of Frascati. Before starting the first measurement of the kaonic deuterium 2p{\rightarrow}1s transition, accurate evaluation of the background rejection. mainly achieved with the Kaon Trigger system, was required. This run, performed in the period 04-26/05/2022 with a 4 He gaseous target, confirmed the 10^5 rejection factor obtained with a reduced version of the setup and different machine conditions in 2021. This important outcome motivated the filling of the target cell with deuterium and the starting of the measurement campaign of the kaonic deuterium 2p{\rightarrow}1s transition.
△ Less
Submitted 4 August, 2022;
originally announced August 2022.
-
MAQRO -- BPS 2023 Research Campaign Whitepaper
Authors:
Rainer Kaltenbaek,
Markus Arndt,
Markus Aspelmeyer,
Peter F. Barker,
Angelo Bassi,
James Bateman,
Alessio Belenchia,
Joel Bergé,
Sougato Bose,
Claus Braxmaier,
Bruno Christophe,
Garrett D. Cole,
Catalina Curceanu,
Animesh Datta,
Maxime Debiossac,
Uroš Delić,
Lajos Diósi,
Andrew A. Geraci,
Stefan Gerlich,
Christine Guerlin,
Gerald Hechenblaikner,
Antoine Heidmann,
Sven Herrmann,
Klaus Hornberger,
Ulrich Johann
, et al. (21 additional authors not shown)
Abstract:
The objective of the proposed MAQRO mission is to harness space for achieving long free-fall times, extreme vacuum, nano-gravity, and cryogenic temperatures to test the foundations of physics in macroscopic quantum experiments. This will result in the development of novel quantum sensors and a means to probe the foundations of quantum physics at the interface with gravity. Earlier studies showed t…
▽ More
The objective of the proposed MAQRO mission is to harness space for achieving long free-fall times, extreme vacuum, nano-gravity, and cryogenic temperatures to test the foundations of physics in macroscopic quantum experiments. This will result in the development of novel quantum sensors and a means to probe the foundations of quantum physics at the interface with gravity. Earlier studies showed that the proposal is feasible but that several critical challenges remain, and key technologies need to be developed. These new technologies will open up the potential for achieving additional science objectives. The proposed research campaign aims to advance the state of the art and to perform the first macroscopic quantum experiments in space. Experiments on the ground, in micro-gravity, and in space will drive the proposed research campaign during the current decade to enable the implementation of MAQRO within the subsequent decade.
△ Less
Submitted 3 February, 2022;
originally announced February 2022.
-
The SIDDHARTA-2 calibration method for high precision kaonic atoms X-ray spectroscopy measurements
Authors:
F Sgaramella,
M Miliucci,
M Bazzi,
D Bosnar,
M Bragadireanu,
M Carminati,
M Cargnelli,
A Clozza,
G Deda,
L De Paolis,
R Del Grande,
C Fiorini,
C Guaraldo,
M Iliescu,
M Iwasaki,
P King,
P Levi Sandri,
J Marton,
P Moskal,
F Napolitano,
S Niedźwiecki,
K Piscicchia,
A Scordo,
H Shi,
M Silarski
, et al. (7 additional authors not shown)
Abstract:
The SIDDHARTA-2 experiment at the DA$Φ$NE collider aims to perform the first kaonic deuterium X-ray transitions to the fundamental level measurement, with a systematic error at the level of a few eV. To achieve this challenging goal the experimental apparatus is equipped with 384 Silicon Drift Detectors (SDDs) distributed around its cryogenic gaseous target. The SDDs developed by the SIDDHARTA-2 c…
▽ More
The SIDDHARTA-2 experiment at the DA$Φ$NE collider aims to perform the first kaonic deuterium X-ray transitions to the fundamental level measurement, with a systematic error at the level of a few eV. To achieve this challenging goal the experimental apparatus is equipped with 384 Silicon Drift Detectors (SDDs) distributed around its cryogenic gaseous target. The SDDs developed by the SIDDHARTA-2 collaboration are suitable for high precision kaonic atoms spectroscopy, thanks to their high energy and time resolutions combined with their radiation hardness. The energy response of each detector must be calibrated and monitored to keep the systematic error, due to processes such as gain fluctuations, at the level of 2-3 eV. This paper presents the SIDDHARTA-2 calibration method which was optimized during the preliminary phase of the experiment in the real background conditions of the DA$Φ$NE collider, which is a fundamental tool to guarantee the high precision spectroscopic performances of the system over long periods of data taking, as that required for the kaonic deuterium measurement.
△ Less
Submitted 28 January, 2022;
originally announced January 2022.
-
Kaonic Atoms at the DA$Φ$NE Collider with the SIDDHARTA-2 Experiment
Authors:
F Napolitano,
F Sgaramella,
M Bazzi,
D Bosnar,
M Bragadireanu,
M Carminati,
M Cargnelli,
A Clozza,
G Deda,
L De Paolis,
R Del Grande,
L Fabbietti,
C Fiorini,
C Guaraldo,
M Iliescu,
M Iwasaki,
P Levi Sandri,
J Marton,
M Miliucci,
P Moskal,
S Niedźwiecki,
K Piscicchia,
A Scordo,
H Shi,
D Sirghi
, et al. (7 additional authors not shown)
Abstract:
Kaonic atoms are a unique tool to explore quantum chromodynamics in the strangeness sector at low energy, with implications reaching neutron stars and dark matter. Precision X-ray spectroscopy can fully unlock the at-threshold isospin dependent antikaon-nucleon scattering lengths, via the atomic transitions to the fundamental level. While the SIDDHARTA experiment at the INFN-LNF DA$Φ$NE collider s…
▽ More
Kaonic atoms are a unique tool to explore quantum chromodynamics in the strangeness sector at low energy, with implications reaching neutron stars and dark matter. Precision X-ray spectroscopy can fully unlock the at-threshold isospin dependent antikaon-nucleon scattering lengths, via the atomic transitions to the fundamental level. While the SIDDHARTA experiment at the INFN-LNF DA$Φ$NE collider successfully measured kaonic hydrogen, its successor SIDDHARTA-2 is starting now its data taking campaign aiming to finally fully disentangle the isoscalar and isovector scattering lengths via the measurement of kaonic deuterium. An overview of the first experimental results from a preparatory run for the SIDDAHARTA-2 experiment is presented.
△ Less
Submitted 27 January, 2022;
originally announced January 2022.
-
A new kaonic helium measurement in gas by SIDDHARTINO at the DAΦNE collider
Authors:
D Sirghi,
F Sirghi,
F Sgaramella,
M Bazzi,
D Bosnar,
M Bragadireanu,
M Carminati,
M Cargnelli,
A Clozza,
G Deda,
L De Paolis,
R Del Grande,
L Fabbietti,
C Fiorini,
C Guaraldo,
M Iliescu,
M Iwasaki,
P Levi Sandri,
J Marton,
M Miliucci,
P Moskal,
F Napolitano,
S Niedźwiecki,
K Piscicchia,
A Scordo
, et al. (8 additional authors not shown)
Abstract:
The SIDDHARTINO experiment at the DAΦNE Collider of INFN-LNF, the pilot run for the SIDDHARTA-2 experiment which aims to perform the measurement of kaonic deuterium transitions to the fundamental level, has successfully been concluded. The paper reports the main results of this run, including the optimization of various components of the apparatus, among which the degrader needed to maximize the f…
▽ More
The SIDDHARTINO experiment at the DAΦNE Collider of INFN-LNF, the pilot run for the SIDDHARTA-2 experiment which aims to perform the measurement of kaonic deuterium transitions to the fundamental level, has successfully been concluded. The paper reports the main results of this run, including the optimization of various components of the apparatus, among which the degrader needed to maximize the fraction of kaons stopped inside the target, through measurements of kaonic helium transitions to the 2p level. The obtained shift and width values are ε_2p = E_exp-E_e.m = 0.2 {\pm} 2.5(stat) {\pm} 2(syst) eV and Γ_2p = 8 {\pm} 10 eV (stat), respectively. This new measurement of the shift, in particular, represents the most precise one for a gaseous target and is expected to contribute to a better understanding of the kaon-nuclei interaction at low energy.
△ Less
Submitted 24 January, 2022;
originally announced January 2022.
-
Positronium imaging with the novel multiphoton PET scanner
Authors:
Paweł Moskal,
Kamil Dulski,
Neha Chug,
Catalina Curceanu,
Eryk Czerwiński,
Meysam Dadgar,
Jan Gajewski,
Aleksander Gajos,
Grzegorz Grudzień,
Beatrix C. Hiesmayr,
Krzysztof Kacprzak,
Łukasz Kapłon,
Hanieh Karimi,
Konrad Klimaszewski,
Grzegorz Korcyl,
Paweł Kowalski,
Tomasz Kozik,
Nikodem Krawczyk,
Wojciech Krzemień,
Ewelina Kubicz,
Piotr Małczak,
Szymon Niedźwiecki,
Monika Pawlik-Niedźwiecka,
Michał Pędziwiatr,
Lech Raczyński
, et al. (11 additional authors not shown)
Abstract:
In vivo assessment of cancer and precise location of altered tissues at initial stages of molecular disorders are important diagnostic challenges. Positronium is copiously formed in the free molecular spaces in the patient's body during positron emission tomography (PET). The positronium properties vary according to the size of inter- and intramolecular voids and the concentration of molecules in…
▽ More
In vivo assessment of cancer and precise location of altered tissues at initial stages of molecular disorders are important diagnostic challenges. Positronium is copiously formed in the free molecular spaces in the patient's body during positron emission tomography (PET). The positronium properties vary according to the size of inter- and intramolecular voids and the concentration of molecules in them such as, e.g., molecular oxygen, O2; therefore, positronium imaging may provide information about disease progression during the initial stages of molecular alterations. Current PET systems do not allow acquisition of positronium images. This study presents a new method that enables positronium imaging by simultaneous registration of annihilation photons and deexcitation photons from pharmaceuticals labeled with radionuclides. The first positronium imaging of a phantom built from cardiac myxoma and adipose tissue is demonstrated. It is anticipated that positronium imaging will substantially enhance the specificity of PET diagnostics.
△ Less
Submitted 16 December, 2021;
originally announced December 2021.
-
Testing CPT symmetry in ortho-positronium decays with positronium annihilation tomography
Authors:
Paweł Moskal,
Aleksander Gajos,
Muhsin Mohammed,
Jyoti Chhokar,
Neha Chug,
Catalina Curceanu,
Eryk Czerwiński,
Meysam Dadgar,
Kamil Dulski,
Marek Gorgol,
Jacek Goworek,
Beatrix Hiesmayr,
Bożena Jasińska,
Krzysztof Kacprzak,
Łukasz Kapłon,
Hanieh Karimi,
Daria Kisielewska,
Konrad Klimaszewski,
Grzegorz Korcyl,
Paweł Kowalski,
Nikodem Krawczyk,
Wojciech Krzemień,
Tomasz Kozik,
Ewelina Kubicz,
Szymon Niedźwiecki
, et al. (13 additional authors not shown)
Abstract:
Charged lepton system symmetry under combined charge, parity, and time-reversal transformation (CPT) remains scarcely tested. Despite stringent quantum-electrodynamic limits, discrepancies in predictions for the electron-positron bound state (positronium atom) motivate further investigation, including fundamental symmetry tests. While CPT noninvariance effects could be manifested in non-vanishing…
▽ More
Charged lepton system symmetry under combined charge, parity, and time-reversal transformation (CPT) remains scarcely tested. Despite stringent quantum-electrodynamic limits, discrepancies in predictions for the electron-positron bound state (positronium atom) motivate further investigation, including fundamental symmetry tests. While CPT noninvariance effects could be manifested in non-vanishing angular correlations between final-state photons and spin of annihilating positronium, measurements were previously limited by knowledge of the latter. Here, we demonstrate tomographic reconstruction techniques applied to three-photon annihilations of ortho-positronium atoms to estimate their spin polarisation without magnetic field or polarised positronium source. We use a plastic-scintillator-based positron-emission-tomography scanner to record ortho-positronium (o-Ps) annihilations with single-event estimation of o-Ps spin and determine the complete spectrum of an angular correlation operator sensitive to CPT-violating effects. We find no violation at the precision level of 10^{-4}, with an over threefold improvement on the previous measurement.
△ Less
Submitted 8 December, 2021;
originally announced December 2021.
-
Underground test of gravity-related wave function collapse
Authors:
S. Donadi,
K. Piscicchia,
C. Curceanu,
L. Diósi,
M. Laubenstein,
A. Bassi
Abstract:
Roger Penrose proposed that a spatial quantum superposition collapses as a back-reaction from spacetime, which is curved in different ways by each branch of the superposition. In this sense, one speaks of gravity-related wave function collapse. He also provided a heuristic formula to compute the decay time of the superposition $\mathord{-}$ similar to that suggested earlier by Lajos Diósi, hence t…
▽ More
Roger Penrose proposed that a spatial quantum superposition collapses as a back-reaction from spacetime, which is curved in different ways by each branch of the superposition. In this sense, one speaks of gravity-related wave function collapse. He also provided a heuristic formula to compute the decay time of the superposition $\mathord{-}$ similar to that suggested earlier by Lajos Diósi, hence the name Diósi-Penrose model. The collapse depends on the effective size of the mass density of particles in the superposition, and is random: this randomness shows up as a diffusion of the particles' motion, resulting, if charged, in the emission of radiation. Here, we compute the radiation emission rate, which is faint but detectable. We then report the results of a dedicated experiment at the Gran Sasso underground laboratory to measure this radiation emission rate. Our result sets a lower bound on the effective size of the mass density of nuclei, which is about three orders of magnitude larger than previous bounds. This rules out the natural parameter-free version of the Diósi-Penrose model.
△ Less
Submitted 26 November, 2021;
originally announced November 2021.
-
Silicon Drift Detectors spectroscopic response during the SIDDHARTA-2 Kaonic Helium run at the DAΦNE collider
Authors:
Marco Miliucci,
Massimiliano Bazzi,
Damir Bosnar,
Mario Bragadireanu,
Marco Carminati,
Michael Cargnelli,
Alberto Clozza,
Catalina Curceanu,
Griseld Deda,
Luca De Paolis,
Raffaele Del Grande,
Carlo Fiorini,
Carlo Guaraldo,
Mihail Iliescu,
Masahiko Iwasaki,
Pietro King,
Paolo Levi Sandri,
Johann Marton,
Paweł Moskal,
Fabrizio Napolitano,
Szymon Niedźwiecki,
Kristian Piscicchia,
Alessandro Scordo,
Francesco Sgaramella,
Hexi Shi
, et al. (8 additional authors not shown)
Abstract:
A large-area Silicon Drift Detectors (SDDs) system has been developed by the SIDDHARTA2 collaboration for high precision light kaonic atoms X-ray spectroscopy at the DAΦNE collider of Istituto Nazionale di Fisica Nucleare - Laboratori Nazionali di Frascati. The SDDs geometry and electric field configuration, combined with their read-out electronics, make these devices suitable to perform high prec…
▽ More
A large-area Silicon Drift Detectors (SDDs) system has been developed by the SIDDHARTA2 collaboration for high precision light kaonic atoms X-ray spectroscopy at the DAΦNE collider of Istituto Nazionale di Fisica Nucleare - Laboratori Nazionali di Frascati. The SDDs geometry and electric field configuration, combined with their read-out electronics, make these devices suitable to perform high precision light kaonic atoms spectroscopy measurements in the high background of the DAΦNE collider. This work presents the spectroscopic response of the SDDs system during the kaonic helium first exotic atoms run of SIDDHARTA-2, preliminary to the kaonic deuterium data taking campaign
△ Less
Submitted 2 November, 2021;
originally announced November 2021.
-
Reflection efficiency and spectra resolutions ray-tracing simulations for the VOXES HAPG crystal based Von Hamos spectrometer
Authors:
V. De Leo,
A. Scordo,
C. Curceanu,
M. Miliucci,
F. Sirghi
Abstract:
The VOXES collaboration at INFN National Laboratories of Frascati developed a prototype of a high resolution Von Hamos X-ray spectrometer using HAPG (Highly Annealed Pyrolytic Graphite) mosaic crystals. This technology allows the employment of extended isotropic sources and could find application in several physics fields. The capability of the spectrometer to reach energy precision and resolution…
▽ More
The VOXES collaboration at INFN National Laboratories of Frascati developed a prototype of a high resolution Von Hamos X-ray spectrometer using HAPG (Highly Annealed Pyrolytic Graphite) mosaic crystals. This technology allows the employment of extended isotropic sources and could find application in several physics fields. The capability of the spectrometer to reach energy precision and resolution below 1 and 10 eV, respectively, when used with wide sources have been already demonstrated. Recently, the response of this device, for a $ρ$ = 206.7 mm cylindrically bent HAPG crystal using $CuKα_{1,2}$ and $FeKα_{1,2}$ XRF lines, has been investigated in terms of reflection efficiency by a dedicated ray-tracing simulation. Details of the simulation procedure and the comparison with the experimental results are presented. This study is crucial in order to retrieve information on the spectrometer signal collection efficiency, especially in the energy range in which the standard calibration procedures cannot be applied.
△ Less
Submitted 2 November, 2021;
originally announced November 2021.
-
Recent results and future prospects of kaonic nuclei at J-PARC
Authors:
F. Sakuma,
S. Ajimura,
T. Akaishi,
H. Asano,
M. Bazzi,
G. Beer,
H. Bhang,
M. Bragadireanu,
P. Buehler,
L. Busso,
M. Cargnelli,
S. Choi,
A. Clozza,
C. Curceanu,
S. Enomoto,
H. Fujioka,
Y. Fujiwara,
T. Fukuda,
C. Guaraldo,
T. Hashimoto,
R. S. Hayano,
T. Hiraiwa,
M. Iio,
M. Iliescu,
K. Inoue
, et al. (51 additional authors not shown)
Abstract:
$\bar K$-nuclear bound systems, kaonic nuclei, have been widely discussed as products of the strongly attractive $\bar K N$ interaction in $I = 0$ channels. Recently, we demonstrated that kaonic nuclei can be produced via in-flight $(K^-,N)$ reactions using the low-momentum DC kaon beam at the J-PARC E15 experiment. We observed the simplest kaonic nuclei, $K^-pp…
▽ More
$\bar K$-nuclear bound systems, kaonic nuclei, have been widely discussed as products of the strongly attractive $\bar K N$ interaction in $I = 0$ channels. Recently, we demonstrated that kaonic nuclei can be produced via in-flight $(K^-,N)$ reactions using the low-momentum DC kaon beam at the J-PARC E15 experiment. We observed the simplest kaonic nuclei, $K^-pp$, having a much deeper binding energy than normal nuclei. For further studies, we have proposed a series of experimental programs for the systematic investigation of light kaonic nuclei, from $\bar K N$ ($Λ(1405)$) to $\bar K NNNN$. In the new experiment approved as J-PARC E80, we will measure the $\bar K NNN$ ($A=3$) system as a first step toward a comprehensive study.
△ Less
Submitted 6 October, 2021;
originally announced October 2021.
-
Optimisation of the event-based TOF filtered back-projection for online imaging in total-body J-PET
Authors:
R. Y. Shopa,
K. Klimaszewski,
P. Kopka,
P. Kowalski,
W. Krzemień,
L. Raczyński,
W. Wiślicki,
N. Chug,
C. Curceanu,
E. Czerwiński,
M. Dadgar,
K. Dulski,
A. Gajos,
B. C. Hiesmayr,
K. Kacprzak,
Ł. Kapłon,
D. Kisielewska,
G. Korcyl,
N. Krawczyk,
E. Kubicz,
Sz. Niedźwiecki,
J. Raj,
S. Sharma,
Shivani,
E. L. Stȩpień
, et al. (2 additional authors not shown)
Abstract:
We perform a parametric study of the newly developed time-of-flight (TOF) image reconstruction algorithm, proposed for the real-time imaging in total-body Jagiellonian PET (J-PET) scanners. The asymmetric 3D filtering kernel is applied at each most likely position of electron-positron annihilation, estimated from the emissions of back-to-back $γ$-photons. The optimisation of its parameters is stud…
▽ More
We perform a parametric study of the newly developed time-of-flight (TOF) image reconstruction algorithm, proposed for the real-time imaging in total-body Jagiellonian PET (J-PET) scanners. The asymmetric 3D filtering kernel is applied at each most likely position of electron-positron annihilation, estimated from the emissions of back-to-back $γ$-photons. The optimisation of its parameters is studied using Monte Carlo simulations of a 1-mm spherical source, NEMA IEC and XCAT phantoms inside the ideal J-PET scanner. The combination of high-pass filters which included the TOF filtered back-projection (FBP), resulted in spatial resolution, 1.5 $\times$ higher in the axial direction than for the conventional 3D FBP. For realistic $10$-minute scans of NEMA IEC and XCAT, which require a trade-off between the noise and spatial resolution, the need for Gaussian TOF kernel components, coupled with median post-filtering, is demonstrated. The best sets of 3D filter parameters were obtained by the Nelder-Mead minimisation of the mean squared error between the resulting and reference images. The approach allows training the reconstruction algorithm for custom scans, using the IEC phantom, when the temporal resolution is below 50 ps. The image quality parameters, estimated for the best outcomes, were systematically better than for the non-TOF FBP.
△ Less
Submitted 27 July, 2021;
originally announced July 2021.
-
Novel CSL bounds from the noise-induced radiation emission from atoms
Authors:
Sandro Donadi,
Kristian Piscicchia,
Raffaele Del Grande,
Catalina Curceanu,
Matthias Laubenstein,
Angelo Bassi
Abstract:
We study spontaneous radiation emission from matter, as predicted by the Continuous Spontaneous Localization (CSL) collapse model. We show that, in an appropriate range of energies of the emitted radiation, the largest contribution comes from the atomic nuclei. Specifically, we show that in the energy range $E\sim 10\,-\,10^{5}$ keV the contribution to the radiation emission from the atomic nuclei…
▽ More
We study spontaneous radiation emission from matter, as predicted by the Continuous Spontaneous Localization (CSL) collapse model. We show that, in an appropriate range of energies of the emitted radiation, the largest contribution comes from the atomic nuclei. Specifically, we show that in the energy range $E\sim 10\,-\,10^{5}$ keV the contribution to the radiation emission from the atomic nuclei grows quadratically with the atomic number of the atom, overtaking the contribution from the electrons, which grows only linearly. This theoretical prediction is then compared with the data from a dedicated experiment performed at the extremely low background environment of the Gran Sasso underground National Laboratory, where the radiation emitted from a sample of Germanium was measured. As a result, we obtain the strongest bounds on the CSL parameters for $r_C\leq 10^{-6}$ m, improving the previous ones by more than an order of magnitude.
△ Less
Submitted 23 July, 2021;
originally announced July 2021.
-
Simulating NEMA characteristics of the modular total-body J-PET scanner -- an economic total-body PET from plastic scintillators
Authors:
Paweł Moskal,
Paweł Kowalski,
Roman Shopa,
Lech Raczyński,
Jakub Baran,
Neha Chug,
Catalina Curceanu,
Eryk Czerwiński,
Meysam Dadgar,
Kamil Dulski,
Aleksander Gajos,
Beatrix Hiesmayr,
Krzysztof Kacprzak,
Łukasz Kapłon,
Daria Kisielewska,
Konrad Klimaszewski,
Przemysław Kopka,
Gregorz Korcyl,
Nikodem Krawczyk,
Wojciech Krzemień,
Ewelina Kubicz,
Szymon Niedźwiecki,
Szymon Parzych,
Juhi Raj,
Sushil Sharma
, et al. (4 additional authors not shown)
Abstract:
The purpose of the presented research is estimation of the performance characteristics of the economic Total-Body Jagiellonian-PET system (TB-J-PET) constructed from plastic scintillators. The characteristics are estimated according to the NEMA NU-2-2018 standards utilizing the GATE package. The simulated detector consists of 24 modules, each built out of 32 plastic scintillator strips (each with…
▽ More
The purpose of the presented research is estimation of the performance characteristics of the economic Total-Body Jagiellonian-PET system (TB-J-PET) constructed from plastic scintillators. The characteristics are estimated according to the NEMA NU-2-2018 standards utilizing the GATE package. The simulated detector consists of 24 modules, each built out of 32 plastic scintillator strips (each with cross section of 6 mm times 30 mm and length of 140 cm or 200 cm) arranged in two layers in regular 24-sided polygon circumscribing a circle with the diameter of 78.6 cm. For the TB-J-PET with an axial field-of-view (AFOV) of 200 cm, a spatial resolutions of 3.7 mm (transversal) and 4.9 mm (axial) are achieved. The NECR peak of 630 kcps is expected at 30 kBq/cc activity concentration and the sensitivity at the center amounts to 38 cps/kBq. The SF is estimated to 36.2 %. The values of SF and spatial resolution are comparable to those obtained for the state-of-the-art clinical PET scanners and the first total-body tomographs: uExplorer and PennPET. With respect to the standard PET systems with AFOV in the range from 16 cm to 26 cm, the TB-J-PET is characterized by an increase in NECR approximately by factor of 4 and by the increase of the whole-body sensitivity by factor of 12.6 to 38. The TOF resolution for the TB-J-PET is expected to be at the level of CRT=240 ps (FWHM). For the TB-J-PET with an axial field-of-view (AFOV) of 140 cm, an image quality of the reconstructed images of a NEMA IEC phantom was presented with a contrast recovery coefficient (CRC) and a background variability parameters. The increase of the whole-body sensitivity and NECR estimated for the TB-J-PET with respect to current commercial PET systems makes the TB-J-PET a promising cost-effective solution for the broad clinical applications of total-body PET scanners.
△ Less
Submitted 3 July, 2021;
originally announced July 2021.
-
Fundamental physics at the strangeness frontier at DAΦNE. Outline of a proposal for future measurements
Authors:
C. Curceanu,
C. Guaraldo,
A. Scordo,
D. Sirghi,
K. Piscicchia,
C. Amsler,
J. Zmeskal,
D. Bosnar,
S. Eidelman,
H. Ohnishi,
Y. Sada
Abstract:
The DAΦNE collider at INFN-LNF is a unique source of low-energy kaons, which was used by the DEAR, SIDDHARTA and AMADEUS collaborations for unique measurements of kaonic atoms and kaon-nuclei interactions. Presently, the SIDDHARTA-2 collaboration is underway to measure the kaonic deuterium exotic atom. With this document we outline a proposal for fundamental physics at the strangeness frontier for…
▽ More
The DAΦNE collider at INFN-LNF is a unique source of low-energy kaons, which was used by the DEAR, SIDDHARTA and AMADEUS collaborations for unique measurements of kaonic atoms and kaon-nuclei interactions. Presently, the SIDDHARTA-2 collaboration is underway to measure the kaonic deuterium exotic atom. With this document we outline a proposal for fundamental physics at the strangeness frontier for future measurements of kaonic atoms and kaon-nuclei interactions at DAΦNE, which is intended to stimulate discussions within the broad scientific community performing research directly or indirectly related to this field.
△ Less
Submitted 19 April, 2021; v1 submitted 13 April, 2021;
originally announced April 2021.
-
Synchronisation and calibration of the 24-modules J-PET prototype with 300~mm axial field of view
Authors:
P. Moskal,
T. Bednarski,
Sz. Niedzwiecki,
M. Silarski,
E. Czerwinski,
T. Kozik,
J. Chhokar,
M. Bała,
C. Curceanu,
R. Del Grande,
M. Dadgar,
K. Dulski,
A. Gajos,
M. Gorgol,
N. Gupta-Sharma,
B. C. Hiesmayr,
B. Jasinska,
K. Kacprzak,
L. Kaplon,
H. Karimi,
D. Kisielewska,
K. Klimaszewski,
G. Korcyl,
P. Kowalski,
N. Krawczyk
, et al. (14 additional authors not shown)
Abstract:
Research conducted in the framework of the J-PET project aims to develop a cost-effective total-body positron emission tomography scanner. As a first step on the way to construct a full-scale J-PET tomograph from long strips of plastic scintillators, a 24-strip prototype was built and tested. The prototype consists of detection modules arranged axially forming a cylindrical diagnostic chamber with…
▽ More
Research conducted in the framework of the J-PET project aims to develop a cost-effective total-body positron emission tomography scanner. As a first step on the way to construct a full-scale J-PET tomograph from long strips of plastic scintillators, a 24-strip prototype was built and tested. The prototype consists of detection modules arranged axially forming a cylindrical diagnostic chamber with the inner diameter of 360 mm and the axial field-of-view of 300 mm. Promising perspectives for a low-cost construction of a total-body PET scanner are opened due to an axial arrangement of strips of plastic scintillators, wchich have a small light attenuation, superior timing properties, and the possibility of cost-effective increase of the axial field-of-view. The presented prototype comprises dedicated solely digital front-end electronic circuits and a triggerless data acquisition system which required development of new calibration methods including time, thresholds and gain synchronization. The system and elaborated calibration methods including first results of the 24-module J-PET prototype are presented and discussed. The achieved coincidence resolving time equals to CRT = 490 $\pm$ 9 ps. This value can be translated to the position reconstruction accuracy $σ(Δl) =$ 18 mm which is fairly position-independent.
△ Less
Submitted 25 August, 2020;
originally announced August 2020.
-
Characterization of the SIDDHARTA-2 luminosity monitor
Authors:
M. Skurzok,
A. Scordo,
S. Niedzwiecki,
A. Baniahmad,
M. Bazzi,
D. Bosnar,
M. Bragadireanu,
M. Carminati,
M. Cargnelli,
A. Clozza,
C. Curceanu,
L. De Paolis,
R. Del Grande,
L. Fabbietti,
C. Fiorini,
C. Guaraldo,
M. Iliescu,
M. Iwasaki,
P. Levi Sandri,
J. Marton,
M. Miliucci,
P. Moskal,
K. Piscicchia,
F. Sgaramella,
H. Shi
, et al. (7 additional authors not shown)
Abstract:
A luminosity monitor, based on plastic scintillator detectors, has been developed for the SIDDHARTA-2 experiment aiming to perform high precision measurements of kaonic atoms and was installed in 2020 on the DAFNE $e^+e^-$ collider at LNF (Laboratori Nazionali di Frascati, INFN). The main goal of this system is to provide the~instantaneous and integrated luminosity of the DAFNE facility by measuri…
▽ More
A luminosity monitor, based on plastic scintillator detectors, has been developed for the SIDDHARTA-2 experiment aiming to perform high precision measurements of kaonic atoms and was installed in 2020 on the DAFNE $e^+e^-$ collider at LNF (Laboratori Nazionali di Frascati, INFN). The main goal of this system is to provide the~instantaneous and integrated luminosity of the DAFNE facility by measuring the rate of $K^+K^-$ correlated pairs emitted by the phi meson decay. This task requires an accurate timing of the DAQ signals, as well as timing resolution below 1ns, in order to disentangle the $K^\pm$ signals from the background minimum ionizing particles (MIPs) produced during the $e^+e^-$ collisions at DAFNE. In this paper the luminosity monitor concept as well as its laboratory characterization and the first results inside DAFNE are presented.
△ Less
Submitted 15 October, 2020; v1 submitted 12 August, 2020;
originally announced August 2020.
-
On self-gravitating strange dark matter halos around galaxies
Authors:
Marco Merafina,
Francesco G. Saturni,
Catalina Curceanu,
Raffaele Del Grande,
Kristian Piscicchia
Abstract:
A new family of nonrelativistic, Newtonian, non-quantum equilibrium configurations describing galactic halos is introduced, by considering strange quark matter conglomerates with masses larger than about 8 GeV as new possible components of the dark matter. Originally introduced to explain the state of matter in neutron stars, such conglomerates may also form in the high-density and temperature con…
▽ More
A new family of nonrelativistic, Newtonian, non-quantum equilibrium configurations describing galactic halos is introduced, by considering strange quark matter conglomerates with masses larger than about 8 GeV as new possible components of the dark matter. Originally introduced to explain the state of matter in neutron stars, such conglomerates may also form in the high-density and temperature conditions of the primordial Universe and then decouple from ordinary baryonic matter, providing the fundamental components of dark matter for the formation of pristine gravitational potential wells and the subsequent evolution of cosmic structures. The obtained results for halo mass and radius are consistent with the rotational velocity curve observed in the Galaxy. Additionally, the average density of such dark matter halos is similar to that derived for halos of dwarf spheroidal galaxies, which can therefore be interpreted as downscaled versions of larger dark matter distributions around Milky Way-sized galaxies and hint for a common origin of the two families of cosmic structures.
△ Less
Submitted 18 September, 2020; v1 submitted 6 July, 2020;
originally announced July 2020.
-
Observation of a $\bar{K}NN$ bound state in the $^3{\rm He} (K^-, Λp)n$ reaction
Authors:
T. Yamaga,
S. Ajimura,
H. Asano,
G. Beer,
H. Bhang,
M. Bragadireanu,
P. Buehler,
L. Busso,
M. Cargnelli,
S. Choi,
C. Curceanu,
S. Enomoto,
H. Fujioka,
Y. Fujiwara,
T. Fukuda,
C. Guaraldo,
T. Hashimoto,
R. S. Hayano,
T. Hiraiwa,
M. Iio,
M. Iliescu,
K. Inoue,
Y. Ishiguro,
T. Ishikawa,
S. Ishimoto
, et al. (44 additional authors not shown)
Abstract:
We have performed an exclusive measurement of the $K^{-}+\! ~^{3}{\rm He} \to Λpn$ reaction at an incident kaon momentum of $1\ {\rm GeV}/c$.In the $Λp$ invariant mass spectrum, a clear peak was observed below the mass threshold of $\bar{K}\!+\!N\!+\!N$, as a signal of the kaonic nuclear bound state, $\bar{K}NN$.The binding energy, decay width, and $S$-wave Gaussian reaction form-factor of this st…
▽ More
We have performed an exclusive measurement of the $K^{-}+\! ~^{3}{\rm He} \to Λpn$ reaction at an incident kaon momentum of $1\ {\rm GeV}/c$.In the $Λp$ invariant mass spectrum, a clear peak was observed below the mass threshold of $\bar{K}\!+\!N\!+\!N$, as a signal of the kaonic nuclear bound state, $\bar{K}NN$.The binding energy, decay width, and $S$-wave Gaussian reaction form-factor of this state were observed to be $B_{K} = 42\pm3({\rm stat.})^{+3}_{-4}({\rm syst.})\ {\rm MeV}$, $Γ_{K} = 100\pm7({\rm stat.})^{+19}_{-9}({\rm syst.})\ {\rm MeV}$, and $Q_{K} = 383\pm11({\rm stat.})^{+4}_{-1}({\rm syst.})\ {\rm MeV}/c$, respectively. The total production cross-section of $\bar{K}NN$, determined by its $Λp$ decay mode, was $σ^{tot}_{K} \cdot BR_{Λp} = 9.3\pm0.8({\rm stat.})^{+1.4}_{-1.0}({\rm syst.})\ μ{\rm b}$.We estimated the branching ratio of the $\bar{K}NN$ state to the $Λp$ and $Σ^{0}p$ decay modes as $BR_{Λp}/BR_{Σ^{0}p} \sim 1.7$, by assuming that the physical processes leading to the $ΣN\!N$ final states are analogous to those of $Λpn$.
△ Less
Submitted 23 June, 2020;
originally announced June 2020.
-
The J-PET detector -- a tool for precision studies of ortho-positronium decays
Authors:
K. Dulski,
S. D. Bass,
J. Chhokar,
N. Chug,
C. Curceanu,
E. Czerwiński,
M. Dadgar,
J. Gajewski,
A. Gajos,
M. Gorgol,
R. Del Grande,
B. C. Hiesmayr,
B. Jasińska,
K. Kacprzak,
Ł. Kapłon,
H. Karimi,
D. Kisielewska,
K. Klimaszewski,
P. Kopka,
G. Korcyl,
P. Kowalski,
T. Kozik,
N. Krawczyk,
W. Krzemień,
E. Kubicz
, et al. (19 additional authors not shown)
Abstract:
The J-PET tomograph is constructed from plastic scintillator strips arranged axially in concentric cylindrical layers. It enables investigations of positronium decays by measurement of the time, position, polarization and energy deposited by photons in the scintillators, in contrast to studies conducted so far with crystal and semiconductor based detection systems where the key selection of events…
▽ More
The J-PET tomograph is constructed from plastic scintillator strips arranged axially in concentric cylindrical layers. It enables investigations of positronium decays by measurement of the time, position, polarization and energy deposited by photons in the scintillators, in contrast to studies conducted so far with crystal and semiconductor based detection systems where the key selection of events is based on the measurement of the photons energies. In this article we show that the J-PET tomograph system is capable of exclusive measurements of the decays of ortho-positronium atoms. We present the first positronium production results, its lifetime distribution measurements and discuss estimation of the influence of various background sources. The tomograph s performance demonstrated here makes it suitable for precision studies of positronium decays including entanglement of the final state photons, positron annihilation lifetime spectroscopy plus molecular imaging diagnostics.
△ Less
Submitted 25 May, 2021; v1 submitted 9 June, 2020;
originally announced June 2020.
-
Hit-time and hit-position reconstruction in strips of plastic scintillators using multi-threshold readouts
Authors:
N. G. Sharma,
M. Silarski,
J. Chhokar,
E. Czerwinski,
C. Curceanu,
K. Dulski,
K. Farbaniec,
A. Gajos,
R. Del Grande,
M. Gorgol,
B. C. Hiesmayr,
B. Jasinska,
K. Kacprzak,
L. Kaplon,
D. Kisielewska,
K. Klimaszewski,
G. Korcyl,
P. Kowalski,
N. Krawczyk,
W. Krzemien,
T. Kozik,
E. Kubicz,
M. Mohammed,
Sz. Niedzwiecki,
M. Palka
, et al. (10 additional authors not shown)
Abstract:
In this article, a new method for the reconstruction of hit-position and hit-time of photons in long scintillator detectors is investigated. This research is motivated by the recent development of the positron emission tomography scanners based on plastic scintillators. The proposed method constitutes a new way of signal processing in Multi-Voltage-Technique. It is based on the determination of th…
▽ More
In this article, a new method for the reconstruction of hit-position and hit-time of photons in long scintillator detectors is investigated. This research is motivated by the recent development of the positron emission tomography scanners based on plastic scintillators. The proposed method constitutes a new way of signal processing in Multi-Voltage-Technique. It is based on the determination of the degree of similarity between the registered signals and the synchronized model signals stored in a library. The library was established for a set of well defined hit-positions along the length of the scintillator. The Mahalanobis distance was used as a measure of similarity between the two compared signals. The method was validated on the experimental data measured using two-strips J-PET prototype with dimensions of 5x9x300 mm$^3$. The obtained Time-of-Flight (TOF) and spatial resolutions amount to 325~ps (FWHM) and 25~mm (FWHM), respectively. The TOF resolution was also compared to the results of an analogous study done using Linear Fitting method. The best TOF resolution was obtained with this method at four pre-defined threshold levels which was comparable to the resolution achieved from the Mahalanobis distance at two pre-defined threshold levels. Although the algorithm of Linear Fitting method is much simpler to apply than the Mahalanobis method, the application of the Mahalanobis distance requires a lower number of applied threshold levels and, hence, decreases the costs of electronics used in PET scanner.
△ Less
Submitted 27 April, 2020;
originally announced April 2020.
-
Estimating relationship between the Time Over Threshold and energy loss by photons in plastic scintillators used in the J-PET scanner
Authors:
S. Sharma,
J. Chhokar,
C. Curceanu,
E. Czerwinski,
M. Dadgar,
K. Dulski,
J. Gajewski,
A. Gajos,
M. Gorgol,
N. Gupta-Sharma,
R. Del Grande,
B. C. Hiesmayr,
B. Jasinska,
K. Kacprzak,
L. Kaplon,
H. Karimi,
D. Kisielewska,
K. Klimaszewski,
G. Korcyl,
P. Kowalski,
T. Kozik,
N. Krawczyk,
W. Krzemien,
E. Kubicz,
M. Mohammed
, et al. (14 additional authors not shown)
Abstract:
Time-Over-Threshold (TOT) technique is being used widely due to its implications in develo** the multi channel readouts mainly when fast signal processing is required. Using TOT technique as a measure of energy loss instead of charge integration methods significantly reduces the signals readout cost by combining the time and energy information. Therefore, this approach can potentially be used in…
▽ More
Time-Over-Threshold (TOT) technique is being used widely due to its implications in develo** the multi channel readouts mainly when fast signal processing is required. Using TOT technique as a measure of energy loss instead of charge integration methods significantly reduces the signals readout cost by combining the time and energy information. Therefore, this approach can potentially be used in J-PET tomograph which is build from plastic scintillators characterized by fast light signals. The drawback in adopting this technique is lying in the non-linear correlation between input energy loss and TOT of the signal. The main motivation behind this work is to develop the relationship between TOT and energy loss and validate it with the J-PET tomograph.
The experiment was performed using the $^{22}$Na beta emitter source placed in the center of the J-PET tomograph. One can obtain primary photons of two different energies: 511 keV photon from the annihilation of positron (direct annihilation or through the formation of para-Positronim atom or pick-off process of ortho-Positronium atoms), and 1275 keV prompt photon. This allows to study the correlation between TOT values and energy loss for energy range up to 1000 keV. As the photon interacts dominantly via Compton scattering inside the plastic scintillator, there is no direct information of primary photon energy. However, using the J-PET geometry one can measure the scattering angle of the interacting photon. Since, $^{22}$Na source emits photons of two different energies, it is required to know unambiguously the energy of incident photons and its corresponding scattering angle for the estimation of energy deposition. In this work, the relationship between Time Over Threshold and energy loss by interacting photons inside the plastic scintillators used in J-PET scanner is established for a energy deposited range 100-1000 keV
△ Less
Submitted 27 November, 2019;
originally announced November 2019.