-
High-Precision Scanning Water Vapor Radiometers for Cosmic Microwave Background Site Characterization and Comparison
Authors:
D. Barkats,
R. Bowens-Rubin,
W. H. Clay,
T. Culp,
R. Hills,
J. M. Kovac,
N. A. Larsen,
S. Paine,
C. D. Sheehy,
A. G. Vieregg
Abstract:
The compelling science case for the observation of B-mode polarization in the cosmic microwave background (CMB) is driving the CMB community to expand the observed sky fraction, either by extending survey sizes or by deploying receivers to potential new northern sites. For ground-based CMB instruments, poorly-mixed atmospheric water vapor constitutes the primary source of short-term sky noise. Thi…
▽ More
The compelling science case for the observation of B-mode polarization in the cosmic microwave background (CMB) is driving the CMB community to expand the observed sky fraction, either by extending survey sizes or by deploying receivers to potential new northern sites. For ground-based CMB instruments, poorly-mixed atmospheric water vapor constitutes the primary source of short-term sky noise. This results in short-timescale brightness fluctuations, which must be rejected by some form of modulation. To maximize the sensitivity of ground-based CMB observations, it is useful to understand the effects of atmospheric water vapor over timescales and angular scales relevant for CMB polarization measurements. To this end, we have undertaken a campaign to perform a coordinated characterization of current and potential future observing sites using scanning 183 GHz water vapor radiometers (WVRs). So far, we have deployed two identical WVR units; one at the South Pole, Antarctica, and the other at Summit Station, Greenland. The former site has a long heritage of ground-based CMB observations and is the current location of the Bicep/Keck Array telescopes as well as the South Pole Telescope. The latter site, though less well characterized, is under consideration as a northern-hemisphere location for future CMB receivers. Data collection from this campaign began in January 2016 at South Pole and July 2016 at Summit Station. Data analysis is ongoing to reduce the data to a single spatial and temporal statistic that can be used for one-to-one site comparison.
△ Less
Submitted 3 August, 2018;
originally announced August 2018.
-
Zeolitic imidazolate framework-coated acoustic sensors for room temperature detection of carbon dioxide and methane
Authors:
Jagannath Devkota,
Ki-Joong Kim,
Paul R. Ohodnicki,
Jeffrey T. Culp,
David W. Greve,
Jonathan W. Lekse
Abstract:
Integration of nanoporous materials such as metal organic frameworks (MOFs) with sensitive transducers can result robust sensing platforms for monitoring gases and chemical vapors for a range of applications. Here, we report on an integration of the zeolitic imidazolate framework-8 (ZIF-8) MOF with surface acoustic wave (SAW) and thickness shear mode quartz crystal microbalance (QCM) devices to mo…
▽ More
Integration of nanoporous materials such as metal organic frameworks (MOFs) with sensitive transducers can result robust sensing platforms for monitoring gases and chemical vapors for a range of applications. Here, we report on an integration of the zeolitic imidazolate framework-8 (ZIF-8) MOF with surface acoustic wave (SAW) and thickness shear mode quartz crystal microbalance (QCM) devices to monitor carbon dioxide(CO2)and methane (CH4) at ambient conditions. The MOF was directly coated on the custom fabricated Y-Z LiNbO3 SAW delay lines (operating frequency,f0 = 436 MHz)and AT-cut Quartz TSM resonators (resonant frequency, f0 = 9 MHz) and the devices were tested for various gases in N2 at ambient condition. The devices were able to detect the changes in CO2 or CH4 concentrations with relatively higher sensitivity to CO2, which was due to its higher adsorption potential and heavier molecular weight. The sensors showed full reversibility and repeatability which were attributed to the physisorption of the gases into the MOF and high stability of the devices. Both types of the sensors showed linear responses relative to changes in the binary gas compositions thereby allowing to construct calibration curves which correlated well with the expected mass changes in the sorbent layer based on mixed-gas gravimetric adsorption isotherms measured on bulk samples.For 200 nm thick films, the SAW sensitivity to CO2 and CH4 were 1.44x10^-6/vol-%, respectivel yagainst the QCM sensitivities 0.24x10^-6/vol-% and 1x10^-8/vol-%,respectively which were evaluated as the fractional change in the signal. The SAW sensors were also evaluated for 100 nm - 300 nm thick films, the sensitivities of which were found to increase with the thickness due to the increased number of pores for adsorption of larger amount of gases. Also, the SAW devices had a good wireless response for detecting gases remotely.
△ Less
Submitted 18 April, 2018; v1 submitted 22 December, 2017;
originally announced December 2017.
-
Magnetic Properties of a Two-Dimensional Mixed-Spin System
Authors:
J. -H. Park,
J. T. Culp,
D. W. Hall,
D. R. Talham,
M. W. Meisel
Abstract:
Using a Langmuir-Blodgett (LB) synthesis method, novel two-dimensional (2D) mixed-spin magnetic systems, in which each magnetic layer is both structurally and magnetically isolated, have been generated. Specifically, a 2D Fe-Ni cyanide-bridged network with a face-centered square grid structure has been magnetically and structurally characterized. The results indicate the presence of ferromagneti…
▽ More
Using a Langmuir-Blodgett (LB) synthesis method, novel two-dimensional (2D) mixed-spin magnetic systems, in which each magnetic layer is both structurally and magnetically isolated, have been generated. Specifically, a 2D Fe-Ni cyanide-bridged network with a face-centered square grid structure has been magnetically and structurally characterized. The results indicate the presence of ferromagnetic exchange interactions between the Fe$^{3+}$ ($S=1/2$) and Ni$^{2+}$ (S=1) centers.
△ Less
Submitted 17 June, 2002;
originally announced June 2002.