-
Directional Response of Several Geometries for Reactor-Neutrino Detectors
Authors:
Mark J. Duvall,
Brian C. Crow,
Max A. A. Dornfest,
John G. Learned,
Marc F. Bergevin,
Steven A. Dazeley,
Viacheslav A. Li
Abstract:
We report simulation studies of six low-energy electron-antineutrino detector designs, with the goal of determining their ability to resolve the direction to an antineutrino source. Such detectors with target masses on the one-ton scale are well-suited to reactor monitoring at distances of 5--25 meters from the core. They can provide accurate measurements of reactor operating power, fuel mix, and…
▽ More
We report simulation studies of six low-energy electron-antineutrino detector designs, with the goal of determining their ability to resolve the direction to an antineutrino source. Such detectors with target masses on the one-ton scale are well-suited to reactor monitoring at distances of 5--25 meters from the core. They can provide accurate measurements of reactor operating power, fuel mix, and burnup, as well as unsurpassed nuclear non-proliferation information in a non-contact cooperating reactor scenario such as those used by IAEA. A number of groups around the world are working on programs to develop detectors similar to some of those in this study. Here, we examine and compare several approaches to detector geometry for their ability not only to detect the inverse beta decay (IBD) reaction, but also to determine the source direction of incident antineutrinos. The information from these detectors provides insight into reactor power and burning profile, which is especially useful in constraining the clandestine production of weapons material. In a live deployment, a non-proliferation detector must be able to isolate the subject reactor, possibly from a field of much-larger power reactors; directional sensitivity can help greatly with this task. We also discuss implications for using such detectors in longer-distance observation of reactors, from a few km to hundreds of km. We have modeled six abstracted detector designs, including two for which we have operational data for validating our computer modeling and analytical processes. We have found that the most promising options, regardless of scale and range, have angular resolutions on the order of a few degrees, which is better than any yet achieved in practice by a factor of at least two.
△ Less
Submitted 2 February, 2024;
originally announced February 2024.
-
White Paper on Light Sterile Neutrino Searches and Related Phenomenology
Authors:
M. A. Acero,
C. A. Argüelles,
M. Hostert,
D. Kalra,
G. Karagiorgi,
K. J. Kelly,
B. Littlejohn,
P. Machado,
W. Pettus,
M. Toups,
M. Ross-Lonergan,
A. Sousa,
P. T. Surukuchi,
Y. Y. Y. Wong,
W. Abdallah,
A. M. Abdullahi,
R. Akutsu,
L. Alvarez-Ruso,
D. S. M. Alves,
A. Aurisano,
A. B. Balantekin,
J. M. Berryman,
T. Bertólez-Martínez,
J. Brunner,
M. Blennow
, et al. (147 additional authors not shown)
Abstract:
This white paper provides a comprehensive review of our present understanding of experimental neutrino anomalies that remain unresolved, charting the progress achieved over the last decade at the experimental and phenomenological level, and sets the stage for future programmatic prospects in addressing those anomalies. It is purposed to serve as a guiding and motivational "encyclopedic" reference,…
▽ More
This white paper provides a comprehensive review of our present understanding of experimental neutrino anomalies that remain unresolved, charting the progress achieved over the last decade at the experimental and phenomenological level, and sets the stage for future programmatic prospects in addressing those anomalies. It is purposed to serve as a guiding and motivational "encyclopedic" reference, with emphasis on needs and options for future exploration that may lead to the ultimate resolution of the anomalies. We see the main experimental, analysis, and theory-driven thrusts that will be essential to achieving this goal being: 1) Cover all anomaly sectors -- given the unresolved nature of all four canonical anomalies, it is imperative to support all pillars of a diverse experimental portfolio, source, reactor, decay-at-rest, decay-in-flight, and other methods/sources, to provide complementary probes of and increased precision for new physics explanations; 2) Pursue diverse signatures -- it is imperative that experiments make design and analysis choices that maximize sensitivity to as broad an array of these potential new physics signatures as possible; 3) Deepen theoretical engagement -- priority in the theory community should be placed on development of standard and beyond standard models relevant to all four short-baseline anomalies and the development of tools for efficient tests of these models with existing and future experimental datasets; 4) Openly share data -- Fluid communication between the experimental and theory communities will be required, which implies that both experimental data releases and theoretical calculations should be publicly available; and 5) Apply robust analysis techniques -- Appropriate statistical treatment is crucial to assess the compatibility of data sets within the context of any given model.
△ Less
Submitted 17 May, 2023; v1 submitted 14 March, 2022;
originally announced March 2022.
-
A Call to Arms Control: Synergies between Nonproliferation Applications of Neutrino Detectors and Large-Scale Fundamental Neutrino Physics Experiments
Authors:
T. Akindele,
T. Anderson,
E. Anderssen,
M. Askins,
M. Bohles,
A. J. Bacon,
Z. Bagdasarian,
A. Baldoni,
A. Barna,
N. Barros,
L. Bartoszek,
A. Bat,
E. W. Beier,
T. Benson,
M. Bergevin,
A. Bernstein,
B. Birrittella,
E. Blucher,
J. Boissevain,
R. Bonventre,
J. Borusinki,
E. Bourret,
D. Brown,
E. J. Callaghan,
J. Caravaca
, et al. (140 additional authors not shown)
Abstract:
The High Energy Physics community can benefit from a natural synergy in research activities into next-generation large-scale water and scintillator neutrino detectors, now being studied for remote reactor monitoring, discovery and exclusion applications in cooperative nonproliferation contexts.
Since approximately 2010, US nonproliferation researchers, supported by the National Nuclear Security…
▽ More
The High Energy Physics community can benefit from a natural synergy in research activities into next-generation large-scale water and scintillator neutrino detectors, now being studied for remote reactor monitoring, discovery and exclusion applications in cooperative nonproliferation contexts.
Since approximately 2010, US nonproliferation researchers, supported by the National Nuclear Security Administration (NNSA), have been studying a range of possible applications of relatively large (100 ton) to very large (hundreds of kiloton) water and scintillator neutrino detectors.
In parallel, the fundamental physics community has been develo** detectors at similar scales and with similar design features for a range of high-priority physics topics, primarily in fundamental neutrino physics. These topics include neutrino oscillation studies at beams and reactors, solar, and geological neutrino measurements, supernova studies, and others.
Examples of ongoing synergistic work at U.S. national laboratories and universities include prototype gadolinium-doped water and water-based and opaque scintillator test-beds and demonstrators, extensive testing and industry partnerships related to large area fast position-sensitive photomultiplier tubes, and the development of concepts for a possible underground kiloton-scale water-based detector for reactor monitoring and technology demonstrations.
Some opportunities for engagement between the two communities include bi-annual Applied Antineutrino Physics conferences, collaboration with U.S. National Laboratories engaging in this research, and occasional NNSA funding opportunities supporting a blend of nonproliferation and basic science R&D, directed at the U.S. academic community.
△ Less
Submitted 20 April, 2022; v1 submitted 28 February, 2022;
originally announced March 2022.
-
Design and Calibration of an Optically Segmented Single Volume Scatter Camera for Neutron Imaging
Authors:
A. Galindo-Tellez,
K. Keefe,
E. Adamek,
E. Brubaker,
B. Crow,
R. Dorrill,
A. Druetzler,
C. J. Felix,
N. Kaneshige,
J. G. Learned,
J. J. Manfredi,
K. Nishimura,
B. Pinto Souza,
D. Schoen,
M. Sweany
Abstract:
The Optically Segmented Single Volume Scatter Camera (OS-SVSC) aims to image neutron sources for non-proliferation applications using the kinematic reconstruction of elastic double-scatter events. Our prototype system consists of 64 EJ-204 organic plastic scintillator bars, each measuring 5 mm $\times$ 5 mm $\times$ 200 mm and individually wrapped in Teflon tape. The scintillator array is opticall…
▽ More
The Optically Segmented Single Volume Scatter Camera (OS-SVSC) aims to image neutron sources for non-proliferation applications using the kinematic reconstruction of elastic double-scatter events. Our prototype system consists of 64 EJ-204 organic plastic scintillator bars, each measuring 5 mm $\times$ 5 mm $\times$ 200 mm and individually wrapped in Teflon tape. The scintillator array is optically coupled to two silicon photomultiplier ArrayJ-60035 64P-PCB arrays, each comprised of 64 individual 6 $\times$ 6 mm J-Series sensors arranged in an 8 $\times$ 8 array. We detail our calibration efforts, beginning with calibrations for the electronics, based on the IRS3D application-specific integrated circuits, and their associated timing resolutions, ranging from 30 ps to 90 ps. With electronics calibrations applied, energy and position calibrations were performed for a set of edge bars using $^{22}$Na and $^{90}$Sr, respectively, reporting an average resolution of (12.07$\pm$0.03) mm for energy depositions between 900 keVee and 1000 keVee. We further demonstrate a position calibration method for the internal bars of the matrix using cosmic-ray muons as an alternative to emission sources that cannot easily access these bars, with an average measured resolution of (14.86$\pm$0.29) mm for depositions between 900 keVee and 1000 keVee. The coincident time resolution reported between pairs of bars measured up to 400 ps from muon acquisitions. Energy and position calibration values measured with muons are consistent with those obtained using particle emission sources.
△ Less
Submitted 17 February, 2021; v1 submitted 4 February, 2021;
originally announced February 2021.
-
CYGNUS: Feasibility of a nuclear recoil observatory with directional sensitivity to dark matter and neutrinos
Authors:
S. E. Vahsen,
C. A. J. O'Hare,
W. A. Lynch,
N. J. C. Spooner,
E. Baracchini,
P. Barbeau,
J. B. R. Battat,
B. Crow,
C. Deaconu,
C. Eldridge,
A. C. Ezeribe,
M. Ghrear,
D. Loomba,
K. J. Mack,
K. Miuchi,
F. M. Mouton,
N. S. Phan,
K. Scholberg,
T. N. Thorpe
Abstract:
Now that conventional weakly interacting massive particle (WIMP) dark matter searches are approaching the neutrino floor, there has been a resurgence of interest in detectors with sensitivity to nuclear recoil directions. A large-scale directional detector is attractive in that it would have sensitivity below the neutrino floor, be capable of unambiguously establishing the galactic origin of a pur…
▽ More
Now that conventional weakly interacting massive particle (WIMP) dark matter searches are approaching the neutrino floor, there has been a resurgence of interest in detectors with sensitivity to nuclear recoil directions. A large-scale directional detector is attractive in that it would have sensitivity below the neutrino floor, be capable of unambiguously establishing the galactic origin of a purported dark matter signal, and could serve a dual purpose as a neutrino observatory. We present the first detailed analysis of a 1000 m$^3$-scale detector capable of measuring a directional nuclear recoil signal at low energies. We propose a modular and multi-site observatory consisting of time projection chambers (TPCs) filled with helium and SF$_6$ at atmospheric pressure. Depending on the TPC readout technology, 10-20 helium recoils above 6 keVr or only 3-4 recoils above 20 keVr would suffice to distinguish a 10 GeV WIMP signal from the solar neutrino background. High-resolution charge readout also enables powerful electron background rejection capabilities well below 10 keV. We detail background and site requirements at the 1000 m$^3$-scale, and identify materials that require improved radiopurity. The final experiment, which we name CYGNUS-1000, will be able to observe 10-40 neutrinos from the Sun, depending on the final energy threshold. With the same exposure, the sensitivity to spin independent cross sections will extend into presently unexplored sub-10 GeV parameter space. For spin dependent interactions, already a 10 m$^3$-scale experiment could compete with upcoming generation-two detectors, but CYGNUS-1000 would improve upon this considerably. Larger volumes would bring sensitivity to neutrinos from an even wider range of sources, including galactic supernovae, nuclear reactors, and geological processes.
△ Less
Submitted 22 December, 2020; v1 submitted 28 August, 2020;
originally announced August 2020.