-
Performance of the polarization leakage correction in the PILOT data
Authors:
J-Ph. Bernard,
A. Bernard,
H. Roussel,
I. Choubani,
D. Alina,
J. Aumont,
A. Hughes,
I. Ristorcelli,
S. Stever,
T. Matsumura S. Sugiyama,
K. Komatsu,
G. de Gasperis,
K. Ferriere,
V. Guillet,
N. Ysard,
P. Ade,
P. de Bernardis,
N. Bray,
B. Crane,
J. P. Dubois,
M. Griffin,
P. Hargrave,
Y. Longval,
S. Louvel,
B. Maffei
, et al. (11 additional authors not shown)
Abstract:
The Polarized Instrument for Long-wavelength Observation of the Tenuous interstellar medium (PILOT) is a balloon-borne experiment that aims to measure the polarized emission of thermal dust at a wavelength of 240 um (1.2 THz). The PILOT experiment flew from Timmins, Ontario, Canada in 2015 and 2019 and from Alice Springs, Australia in April 2017. The in-flight performance of the instrument during…
▽ More
The Polarized Instrument for Long-wavelength Observation of the Tenuous interstellar medium (PILOT) is a balloon-borne experiment that aims to measure the polarized emission of thermal dust at a wavelength of 240 um (1.2 THz). The PILOT experiment flew from Timmins, Ontario, Canada in 2015 and 2019 and from Alice Springs, Australia in April 2017. The in-flight performance of the instrument during the second flight was described in Mangilli et al. 2019. In this paper, we present data processing steps that were not presented in Mangilli et al. 2019 and that we have recently implemented to correct for several remaining instrumental effects. The additional data processing concerns corrections related to detector cross-talk and readout circuit memory effects, and leakage from total intensity to polarization. We illustrate the above effects and the performance of our corrections using data obtained during the third flight of PILOT, but the methods used to assess the impact of these effects on the final science-ready data, and our strategies for correcting them will be applied to all PILOT data. We show that the above corrections, and in particular that for the intensity to polarization leakage, which is most critical for accurate polarization measurements with PILOT, are accurate to better than 0.4 % as measured on Jupiter during flight#3.
△ Less
Submitted 7 May, 2022;
originally announced May 2022.
-
PILOT balloon-borne experiment in-flight performance
Authors:
A. Mangilli,
G. Foënard,
J. Aumont,
A. Hughes,
B. Mot,
J-Ph. Bernard,
A. Lacourt,
I. Ristorcelli,
Y. Longval,
P. Ade,
Y. André,
L. Bautista,
P. deBernardis,
O. Boulade,
F. Bousqet,
M. Bouzit,
V. Buttice,
M. Charra,
B. Crane,
E. Doumayrou,
J. P. Dubois,
C. Engel,
M. Griffin,
S. Grabarnik,
P. Hargrave
, et al. (26 additional authors not shown)
Abstract:
The Polarized Instrument for Long-wavelength Observation of the Tenuous interstellar medium (PILOT) is a balloon-borne experiment aiming at measuring the polarized emission of thermal dust at a wavelength of 240 mm (1.2 THz). A first PILOT flight (flight#1) of the experiment took place from Timmins, Ontario, Canada, in September 2015 and a second flight (flight#2) took place from Alice Springs, Au…
▽ More
The Polarized Instrument for Long-wavelength Observation of the Tenuous interstellar medium (PILOT) is a balloon-borne experiment aiming at measuring the polarized emission of thermal dust at a wavelength of 240 mm (1.2 THz). A first PILOT flight (flight#1) of the experiment took place from Timmins, Ontario, Canada, in September 2015 and a second flight (flight#2) took place from Alice Springs, Australia in april 2017. In this paper, we present the inflight performance of the instrument during these two flights. We concentrate on performances during flight#2, but allude to flight#1 performances if significantly different. We first present a short description of the instrument and the flights. We determine the time constants of our detectors combining inflight information from the signal decay following high energy particle impacts (glitches) and of our internal calibration source. We use these time constants to deconvolve the data timelines and analyse the optical quality of the instrument as measured on planets. We then analyse the structure and polarization of the instrumental background. We measure the detector response flat field and its time variations using the signal from the residual atmosphere and of our internal calibration source. Finally, we analyze the detector noise spectral and temporal properties. The in-flight performances are found to be satisfactory and globally in line with expectations from ground calibrations. We conclude by assessing the expected in-flight sensitivity of the instrument in light of the above in-flight performances.
△ Less
Submitted 7 January, 2019; v1 submitted 16 April, 2018;
originally announced April 2018.
-
PILOT: a balloon-borne experiment to measure the polarized FIR emission of dust grains in the interstellar medium
Authors:
R. Misawa,
J-Ph. Bernard,
P. Ade,
Y. Andre,
P. deBernardis,
M. Bouzit,
M. Charra,
B. Crane,
J. P. Dubois,
C. Engel,
M. Griffin,
P. Hargrave,
B. Leriche,
Y. Longval,
S. Maes,
C. Marty,
W. Marty,
S. Masi,
B. Mot,
J. Narbonne,
F. Pajot,
G. Pisano,
N. Ponthieu,
I. Ristorcelli,
L. Rodriguez
, et al. (4 additional authors not shown)
Abstract:
Future cosmology space missions will concentrate on measuring the polarization of the Cosmic Microwave Background, which potentially carries invaluable information about the earliest phases of the evolution of our universe. Such ambitious projects will ultimately be limited by the sensitivity of the instrument and by the accuracy at which polarized foreground emission from our own Galaxy can be su…
▽ More
Future cosmology space missions will concentrate on measuring the polarization of the Cosmic Microwave Background, which potentially carries invaluable information about the earliest phases of the evolution of our universe. Such ambitious projects will ultimately be limited by the sensitivity of the instrument and by the accuracy at which polarized foreground emission from our own Galaxy can be subtracted out. We present the PILOT balloon project which will aim at characterizing one of these foreground sources, the polarization of the dust continuum emission in the diffuse interstellar medium. The PILOT experiment will also constitute a test-bed for using multiplexed bolometer arrays for polarization measurements. We present the results of ground tests obtained just before the first flight of the instrument.
△ Less
Submitted 13 October, 2014;
originally announced October 2014.
-
A material system for reliable low voltage anodic electrowetting
Authors:
M. Khodayari,
J. Carballo,
Nathan B. Crane
Abstract:
Electrowetting on dielectric is demonstrated with a thin spin-coated fluoropolymer over an aluminum electrode. Previous efforts to use thin spin-coated dielectric layers for electrowetting have shown limited success due to defects in the layers. However, when used with a citric acid electrolyte and anodic voltages, repeatable droplet actuation is achieved for 5000 cycles with an actuation of just…
▽ More
Electrowetting on dielectric is demonstrated with a thin spin-coated fluoropolymer over an aluminum electrode. Previous efforts to use thin spin-coated dielectric layers for electrowetting have shown limited success due to defects in the layers. However, when used with a citric acid electrolyte and anodic voltages, repeatable droplet actuation is achieved for 5000 cycles with an actuation of just 10 V. This offers the potential for low voltage electrowetting systems that can be manufactured with a simple low-cost process.
△ Less
Submitted 25 February, 2013;
originally announced February 2013.
-
Floating Electrode Electrowetting on Hydrophobic Dielectric with an SiO2 Layer
Authors:
Mehdi Khodayari,
Benjamin Hahne,
Nathan B. Crane,
Alex A. Volinsky
Abstract:
Floating electrode electrowetting is caused by dc voltage applied to a liquid droplet on the Cytop surface, without electrical connection to the substrate. The effect is caused by the charge separation in the floating electrode. A highly-resistive thermally-grown SiO2 layer underneath the Cytop enables the droplet to hold charges without leakage, which is the key contribution. Electrowetting with…
▽ More
Floating electrode electrowetting is caused by dc voltage applied to a liquid droplet on the Cytop surface, without electrical connection to the substrate. The effect is caused by the charge separation in the floating electrode. A highly-resistive thermally-grown SiO2 layer underneath the Cytop enables the droplet to hold charges without leakage, which is the key contribution. Electrowetting with an SiO2 layer shows a memory effect, where the wetting angle stays the same after the auxiliary electrode is removed from the droplet in both conventional and floating electrode electrowetting. Floating electrode electrowetting provides an alternative configuration for develo** advanced electrowetting-based devices.
△ Less
Submitted 30 April, 2013; v1 submitted 24 February, 2013;
originally announced February 2013.