-
Threshold Response to Stochasticity in Morphogenesis
Authors:
George Courcoubetis,
Sammi Ali,
Sergey V Nuzhdin,
Paul Marjoram,
Stephan Haas
Abstract:
During development of biological organisms, multiple complex structures are formed. In many instances, these structures need to exhibit a high degree of order to be functional, although many of their constituents are intrinsically stochastic. Hence, it has been suggested that biological robustness ultimately must rely on complex gene regulatory networks and clean-up mechanisms. Here we explore dev…
▽ More
During development of biological organisms, multiple complex structures are formed. In many instances, these structures need to exhibit a high degree of order to be functional, although many of their constituents are intrinsically stochastic. Hence, it has been suggested that biological robustness ultimately must rely on complex gene regulatory networks and clean-up mechanisms. Here we explore developmental processes that have evolved inherent robustness against stochasticity. In the context of the Drosophila eye disc, multiple optical units, ommatidia, develop into crystal-like patterns. During the larva-to-pupa stage of metamorphosis, the centers of the ommatidia are specified initially through the diffusion of morphogens, followed by the specification of R8 cells. Establishing the R8 cell is crucial in setting up the geometric, and functional, relationships of cells within an ommatidium and among neighboring ommatidia. Here we study a mathematical model of these spatio-temporal processes in the presence of stochasticity, defining and applying measures that quantify order within the resulting spatial patterns. We observe a universal sigmoidal response to increasing transcriptional noise. Ordered patterns persist up to a threshold noise level in the model parameters. As the noise is further increased past a threshold point of no return, these ordered patterns rapidly become disordered. Such robustness in development allows for the accumulation of genetic variation without any observable changes in phenotype. We argue that the observed sigmoidal dependence introduces robustness allowing for sizable amounts of genetic variation and transcriptional noise to be tolerated in natural populations without resulting in phenotype variation.
△ Less
Submitted 5 April, 2018;
originally announced April 2018.
-
Updated Results of a Solid-State Sensor Irradiation Study for ILC Extreme Forward Calorimetry
Authors:
George Courcoubetis,
Wyatt Crockett,
Vitaliy Fadeyev,
Caleb Fink,
Nikolas Guillemaud,
Cesar Gonzalez Renteria,
Benjamin Gruey,
Patrick LaBarre,
Forest Martinez-McKinney,
Greg Rischbieter,
Bruce A. Schumm,
Edwin Spencer,
Max Wilder
Abstract:
Detectors proposed for the International Linear Collider (ILC) incorporate a tungsten sampling calorimeter (`BeamCal') intended to reconstruct showers of electrons, positrons and photons that emerge from the interaction point of the collider with angles between 5 and 50 milliradians. For the innermost radius of this calorimeter, radiation doses at shower max are expected to reach 100 Mrad per year…
▽ More
Detectors proposed for the International Linear Collider (ILC) incorporate a tungsten sampling calorimeter (`BeamCal') intended to reconstruct showers of electrons, positrons and photons that emerge from the interaction point of the collider with angles between 5 and 50 milliradians. For the innermost radius of this calorimeter, radiation doses at shower max are expected to reach 100 Mrad per year, primarily due to minimum-ionizing electrons and positrons that arise in the induced electromagnetic showers of e+e- `beamstrahlung' pairs produced in the ILC beam-beam interaction. However, radiation damage to calorimeter sensors may be dominated by hadrons induced by nuclear interactions of shower photons, which are much more likely to contribute to the non-ionizing energy loss that has been observed to damage sensors exposed to hadronic radiation. We report here on the results of SLAC Experiment T-506, for which several different types of silicon diode and gallium-arsenide sensors were exposed to doses of radiation induced by showering electrons of energy 3.5-13.3 GeV. By embedding the sensor under irradiation within a tungsten radiator, the exposure incorporated hadronic species that would potentially contribute to the degradation of a sensor mounted in a precision sampling calorimeter. Depending on sensor technology, efficient charge collection was observed for doses as large as 270 Mrad.
△ Less
Submitted 27 February, 2016;
originally announced February 2016.
-
Updated Results of a Solid-State Sensor Irradiation Study for ILC Extreme Forward Calorimetry
Authors:
George Courcoubetis,
Wyatt Crockett,
Vitaliy Fadeyev,
Thomas Kelley,
Forest Martinez-McKinney,
Bruce A. Schumm,
Edwin Spencer,
Vivian Tang,
Max Wilder
Abstract:
Detectors proposed for the International Linear Collider (ILC) incorporate a tungsten sampling calorimeter (`BeamCal') intended to reconstruct showers of electrons, positrons and photons that emerge from the interaction point of the collider with angles between 5 and 50 milliradians. For the innermost radius of this calorimeter, radiation doses at shower-max are expected to reach 100 MRad per year…
▽ More
Detectors proposed for the International Linear Collider (ILC) incorporate a tungsten sampling calorimeter (`BeamCal') intended to reconstruct showers of electrons, positrons and photons that emerge from the interaction point of the collider with angles between 5 and 50 milliradians. For the innermost radius of this calorimeter, radiation doses at shower-max are expected to reach 100 MRad per year, primarily due to minimum-ionizing electrons and positrons that arise in the induced electromagnetic showers of e+e- `beamstrahlung' pairs produced in the ILC beam-beam interaction. However, radiation damage to calorimeter sensors may be dominated by hadrons induced by nuclear interactions of shower photons, which are much more likely to contribute to the non-ionizing energy loss that has been observed to damage sensors exposed to hadronic radiation. We report here on the results of SLAC Experiment T-506, for which several different types of silicon diode and gallium-arsenide sensors were exposed to doses of radiation induced by showering electrons of energy 3.5-10.6 GeV. By embedding the sensor under irradiation within a tungsten radiator, the exposure incorporated hadronic species that would potentially contribute to the degradation of a sensor mounted in a precision sampling calorimeter. Depending on sensor technology, efficient charge collection was observed for doses as large as 220 MRad.
△ Less
Submitted 25 March, 2015;
originally announced March 2015.