-
Study of waveguide background at visible wavelengths for on-chip nanoscopy
Authors:
David A. Coucheron,
Øystien I. Helle,
James S. Wilkinson,
Ganapathy Senthil Murugan,
Carlos Domínguez,
Hallvar Angelskår,
Balpreet S. Ahluwalia
Abstract:
On-chip super-resolution optical microscopy is an emerging field relying on waveguide excitation with visible light. Here, we investigate two commonly used high-refractive index waveguide platforms, tantalum pentoxide (Ta$_2$O$_5$) and silicon nitride (Si$_3$N$_4$), with respect to their background with excitation in the range 488-640 nm. The background strength from these waveguides were estimate…
▽ More
On-chip super-resolution optical microscopy is an emerging field relying on waveguide excitation with visible light. Here, we investigate two commonly used high-refractive index waveguide platforms, tantalum pentoxide (Ta$_2$O$_5$) and silicon nitride (Si$_3$N$_4$), with respect to their background with excitation in the range 488-640 nm. The background strength from these waveguides were estimated by imaging fluorescent beads. The spectral dependence of the background from these waveguide platforms was also measured. For 640 nm wavelength excitation both the materials had a weak background, but the background increases progressively for shorter wavelengths for Si3N4. We further explored the effect of the waveguide background on localization precision of single molecule localization for direct stochastic optical reconstruction microscopy (dSTORM). An increase in background for Si$_3$N$_4$ at 488 nm is shown to reduce the localization precision and thus the resolution of the reconstructed images. The localization precision at 640 nm was very similar for both the materials. Thus, for shorter wavelength applications Ta$_2$O$_5$ is preferable. Reducing the background from Si$_3$N$_4$ at shorter wavelengths via improved fabrication will be worth pursuing.
△ Less
Submitted 25 January, 2021;
originally announced January 2021.
-
Multi-modal on-chip nanoscopy and quantitative phase image reveals the morphology of liver sinusoidal enodthelial cells
Authors:
David A. Coucheron,
Ankit Butola,
Karolina Szafranska,
Azeem Ahmad,
Jean-Claude Tinguely,
Peter McCourt,
Paramasivam Senthilkumaran,
Dalip Singh Mehta,
Balpreet Singh Ahluwalia
Abstract:
Visualization of three-dimensional morphological changes in the subcellular structures of a biological specimen is one of the greatest challenges in life science. Despite conspicuous refinements in optical nanoscopy, determination of quantitative changes in subcellular structure, i.e., size and thickness, remains elusive. We present an integrated chip-based optical nanoscopy set-up that provides a…
▽ More
Visualization of three-dimensional morphological changes in the subcellular structures of a biological specimen is one of the greatest challenges in life science. Despite conspicuous refinements in optical nanoscopy, determination of quantitative changes in subcellular structure, i.e., size and thickness, remains elusive. We present an integrated chip-based optical nanoscopy set-up that provides a lateral optical resolution of 61 nm combined with a highly sensitive quantitative phase microscopy (QPM) system with a spatial phase sensitivity of $\pm$20 mrad. We use the system to obtain the 3D morphology of liver sinusoidal endothelial cells (LSECs) combined with super-resolved spatial information. LSECs have a unique morphology with nanopores that are present in the plasma membrane, called fenestration. The fenestrations are grouped in clusters called sieve plates, which are around 100 nm thick. Thus, imaging and quantification of fenestration and sieve plate thickness requires resolution and sensitivity of sub-100 nm along both lateral and axial directions. In the chip-based nanoscope, the optical waveguides are used both for hosting and illuminating the sample. A strong evanescent field is generated on top of the waveguide surface for single molecule fluorescence excitation. The fluorescence signal is captured by an upright microscope, which is converted into a Linnik-type interferometer to sequentially acquire both super-resolved images and quantitative phase information of the sample. The multi-modal microscope provided an estimate of the fenestration diameter of 124$\pm$41 nm and revealed the average estimated thickness of the sieve plates in the range of 91.2$\pm$43.5 nm for two different cells. The combination of these techniques offers visualization of both the lateral size (using nanoscopy) and the thickness map of sieve plates, i.e. discrete clusters fenestrations in QPM mode.
△ Less
Submitted 22 July, 2020;
originally announced July 2020.
-
Chip-based Resonance Raman Spectroscopy Using Tantalum Pentoxide Waveguides
Authors:
David A. Coucheron,
Dushan N. Wadduwage,
G. Senthil Murugan,
Peter T. C. So,
Balpreet S. Ahluwalia
Abstract:
Blood analysis is an important diagnostic tool, as it provides a wealth of information about the patient health. Raman spectroscopy is a promising tool in blood analysis, but widespread clinical application is limited by its low signal strength, as well as complex and costly instrumentation. The growing field of waveguide-based Raman spectroscopy tries to solve these challenges by working towards…
▽ More
Blood analysis is an important diagnostic tool, as it provides a wealth of information about the patient health. Raman spectroscopy is a promising tool in blood analysis, but widespread clinical application is limited by its low signal strength, as well as complex and costly instrumentation. The growing field of waveguide-based Raman spectroscopy tries to solve these challenges by working towards fully integrated Raman sensors with increased interaction areas. In this work, we demonstrate on-chip resonance Raman measurements of hemoglobin, a crucial component of blood, at 532 nm excitation using a tantalum pentoxide (Ta2O5) waveguide platform. We have also characterized the background signal from Ta2O5 waveguide material when excited at 532 nm. In addition, we demonstrate spontaneous Raman measurements of iso-propanol and methanol using the same platform. Our results suggest that Ta2O5 is a promising waveguide platform for resonance Raman spectroscopy at 532 nm, and in particular for blood analysis.
△ Less
Submitted 11 November, 2018;
originally announced November 2018.