-
Development of wavelength-shifting PEN foils for next generation experiments
Authors:
M. Kuźniak,
S. Pawłowski,
A. Abramowicz,
A. F. V. Cortez,
M. Kumosiński,
T. Łęcki,
G. Nieradka
Abstract:
Polyethylene naphthalate (PEN) foils have been demonstrated as a wavelength shifter suitable for operation in liquid argon. At the same time, wavelength shifting efficiency of technical grades of PEN, commercially available on the market, is lower than that of tetraphenyl butadiene (TPB). This paper reports on an R&D program focused on exploring the intrinsic limitations of PEN and optimizing it f…
▽ More
Polyethylene naphthalate (PEN) foils have been demonstrated as a wavelength shifter suitable for operation in liquid argon. At the same time, wavelength shifting efficiency of technical grades of PEN, commercially available on the market, is lower than that of tetraphenyl butadiene (TPB). This paper reports on an R&D program focused on exploring the intrinsic limitations of PEN and optimizing it for the highest achievable wavelength shifting efficiency.
△ Less
Submitted 28 March, 2024;
originally announced March 2024.
-
FAT-GEMs: (Field Assisted) Transparent Gaseous-Electroluminescence Multipliers
Authors:
S. Leardini,
A. Sáa-Hernández,
M. Kuźniak,
D. González-Díaz,
C. D. R. Azevedo,
F. Lucas,
P. Amedo,
A. F. V. Cortez,
D. Fernández-Posada,
B. Mehl,
G. Nieradka,
R. de Oliveira,
V. Peskov,
T. Sworobowicz,
S. Williams
Abstract:
The idea of implementing electroluminescence-based amplification through transparent multi-hole structures (FAT-GEMs) has been entertained for some time. Arguably, for such a technology to be attractive it should perform at least at a level comparable to conventional alternatives based on wires or meshes. We present now a detailed calorimetric study carried out for 5.9~keV X-rays in xenon, for pre…
▽ More
The idea of implementing electroluminescence-based amplification through transparent multi-hole structures (FAT-GEMs) has been entertained for some time. Arguably, for such a technology to be attractive it should perform at least at a level comparable to conventional alternatives based on wires or meshes. We present now a detailed calorimetric study carried out for 5.9~keV X-rays in xenon, for pressures ranging from 2 to 10~bar, resorting to different geometries, production and post-processing techniques. At a reference voltage 5~times above the electroluminescence threshold ($E_{EL,th}\sim0.7$~kV/cm/bar), the number of photoelectrons measured for the best structure was found to be just 18\%~below that obtained for a double-mesh with the same thickness and at the same distance. The energy resolution stayed within 10\% (relative) of the double-mesh value.
An innovative characteristic of the structure is that vacuum ultraviolet (VUV) transparency of the polymethyl methacrylate (PMMA) substrate was achieved, effectively, through tetraphenylbutadiene (TPB) coating of the electroluminescence channels combined with indium tin oxide (ITO) coating of the electrodes. This resulted in a $\times 2.25$-increased optical yield (compared to the bare structure), that was found to be in good agreement with simulations if assuming a TPB wavelength-shifting-efficiency at the level of WLSE=0.74-1.28, compatible with expected values. This result, combined with the stability demonstrated for the TPB coating under electric field (over 20~h of continuous operation), shows great potential to revolutionize electroluminescence-based instrumentation.
△ Less
Submitted 28 February, 2024; v1 submitted 18 January, 2024;
originally announced January 2024.
-
Cryogenic setup for the characterization of wavelength-shifting materials for noble element radiation detectors
Authors:
S. Choudhary,
A. F. V. Cortez,
M. Kuźniak,
G. Nieradka,
T. Sworobowicz,
Ł. Świderski,
T. Szczęśniak
Abstract:
In the present work, we describe a cryogenic setup for studies of wavelength-shifting materials for optimised light collection in noble element radiation detectors, and discuss the commissioning results. This SiPM-based setup uses alpha induced scintillation in gaseous argon as the vacuum ultraviolet light source with the goal of characterising materials, such as polyethylene naphthalate (PEN) and…
▽ More
In the present work, we describe a cryogenic setup for studies of wavelength-shifting materials for optimised light collection in noble element radiation detectors, and discuss the commissioning results. This SiPM-based setup uses alpha induced scintillation in gaseous argon as the vacuum ultraviolet light source with the goal of characterising materials, such as polyethylene naphthalate (PEN) and tetraphenyl butadiene (TPB), in terms of their wavelength-shifting efficiency. Further extensions of the system are currently being studied. The foreseen upgrades are expected to allow the study of GEM-like structures potentially interesting for rare-event searches. The design of the setup will be addressed along with the first results.
△ Less
Submitted 10 January, 2024;
originally announced January 2024.
-
A data acquisition and reconstruction software for SAMPA-SRS integration
Authors:
G. G. A. de Souza,
T. S. Abelha,
T. B. Saramela,
A. F. V. Cortez,
H. N. da Luz,
C. G. Penteado,
M. Bregant
Abstract:
In this work we present the latest developments in the SAMPA-SRS integration. A software was developed to improve the acquisition configuration, acquisition, and decoding of the data. The complete framework was tested using a triple GEM-based position sensitive detector for X-rays. The detector was operated in Ar/CO$_2$ (70/30) in continuous flow, at atmospheric pressure and made use of a 1 dimens…
▽ More
In this work we present the latest developments in the SAMPA-SRS integration. A software was developed to improve the acquisition configuration, acquisition, and decoding of the data. The complete framework was tested using a triple GEM-based position sensitive detector for X-rays. The detector was operated in Ar/CO$_2$ (70/30) in continuous flow, at atmospheric pressure and made use of a 1 dimension strip readout (200$μ$m wide strips at a pitch of 400$μ$m) for charge collection. With this detector a position resolution of better than 833$μ$m was obtained, with an energy resolution of 14.2% ($σ/E$) for 5.9keV.
△ Less
Submitted 8 May, 2023; v1 submitted 20 March, 2023;
originally announced March 2023.
-
Study of the loss of Xenon Scintillation in Xenon-Trimethylamine Mixtures
Authors:
A. M. F. Trindade,
J. Escada,
A. F. V. Cortez,
F. I. G. M. Borges,
F. P. Santos,
C. Adams,
V. Álvarez,
L. Arazi,
C. D. R. Azevedo,
F. Ballester,
J. M. Benlloch-Rodríguez,
A. Botas,
S. Cárcel,
J. V. Carríon,
S. Cebrián,
C. A. N. Conde,
J. Díaz,
M. Diesburg,
R. Esteve,
R. Felkai,
L. M. P. Fernandes,
P. Ferrario,
A. L. Ferreira,
E. D. C. Freitas,
A. Goldschmidt
, et al. (53 additional authors not shown)
Abstract:
This work investigates the capability of TMA ((CH3)3N) molecules to shift the wavelength of Xe VUV emission (160-188 nm) to a longer, more manageable, wavelength (260-350 nm). Light emitted from a Xe lamp was passed through a gas chamber filled with Xe-TMA mixtures at 800 Torr and detected with a photomultiplier tube. Using bandpass filters in the proper transmission ranges, no reemitted light was…
▽ More
This work investigates the capability of TMA ((CH3)3N) molecules to shift the wavelength of Xe VUV emission (160-188 nm) to a longer, more manageable, wavelength (260-350 nm). Light emitted from a Xe lamp was passed through a gas chamber filled with Xe-TMA mixtures at 800 Torr and detected with a photomultiplier tube. Using bandpass filters in the proper transmission ranges, no reemitted light was observed experimentally. Considering the detection limit of the experimental system, if reemission by TMA molecules occurs, it is below 0.3% of the scintillation absorbed in the 160-188 nm range. An absorption coefficient value for xenon VUV light by TMA of 0.43+/-0.03 cm-1.Torr-1 was also obtained. These results can be especially important for experiments considering TMA as a molecular additive to Xe in large volume optical time projection chambers.
△ Less
Submitted 13 December, 2018;
originally announced December 2018.