High Rate Studies of the ATLAS sTGC Detector and Optimization of the Filter Circuit on the Input of the Front-End Amplifier
Authors:
Siyuan Sun,
Luca Moleri,
Gerardo Vasquez,
Peter Teterin,
Sabrina Corsetti,
Liang Guan,
Benoit Lefebvre,
Enrique Kajomovitz,
Lorne Levinson,
Nachman Lupu,
Rob McPherson,
Alexander Vdovin,
Rongkun Wang,
Bing Zhou,
Junjie Zhu
Abstract:
The Large Hadron Collider (LHC) at CERN is expected to be upgraded to the High-Luminosity LHC (HL-LHC) by 2029 and achieve instantaneous luminosity around 5 - 7.5 $\times$ 10$^{34}$cm$^{-2}$ s$^{-1}$. This represents a more than 3-4 fold increase in the instantaneous luminosity compared to what has been achieved in Run 2. The New Small Wheel (NSW) upgrade is designed to be able to operate efficien…
▽ More
The Large Hadron Collider (LHC) at CERN is expected to be upgraded to the High-Luminosity LHC (HL-LHC) by 2029 and achieve instantaneous luminosity around 5 - 7.5 $\times$ 10$^{34}$cm$^{-2}$ s$^{-1}$. This represents a more than 3-4 fold increase in the instantaneous luminosity compared to what has been achieved in Run 2. The New Small Wheel (NSW) upgrade is designed to be able to operate efficiently in this high background rate environment. In this article, we summarize multiple performance studies of the small-strip Thin Gap Chamber (sTGC) at high rate using nearly final front-end electronics. We demonstrate that the efficiency versus rate distribution can be well described by an exponential decay with electronics dead-time being the primary cause of loss of efficiency at high rate. We then demonstrate several methods that can decrease the electronics dead-time and therefore minimize efficiency loss. One such method is to install either a pi-network input filter or pull-up resistor to minimize the charge input into the amplifier. We optimized the pi-network capacitance and pull-up resistor resistance using the results from our measurements. The results shown here were not only critical to finalizing the components on the front-end board, but also are critical for setting the optimal operating parameters of the sTGC detector and electronics in the ATLAS cavern.
△ Less
Submitted 17 April, 2023; v1 submitted 6 December, 2022;
originally announced December 2022.
A Liquid Hydrogen Target for the MUSE Experiment at PSI
Authors:
P. Roy,
S. Corsetti,
M. Dimond,
M. Kim,
L. Le Pottier,
W. Lorenzon,
R. Raymond,
H. Reid,
N. Steinberg,
N. Wuerfel,
K. Deiters,
W. J. Briscoe,
A. Golossanov,
T. Rostomyan
Abstract:
A 280 ml liquid hydrogen target has been constructed and tested for the MUSE experiment at PSI to investigate the proton charge radius via simultaneous measurement of elastic muon-proton and elastic electron-proton scattering. To control systematic uncertainties at a sub-percent level, strong constraints were put on the amount of material surrounding the target and on its temperature stability. Th…
▽ More
A 280 ml liquid hydrogen target has been constructed and tested for the MUSE experiment at PSI to investigate the proton charge radius via simultaneous measurement of elastic muon-proton and elastic electron-proton scattering. To control systematic uncertainties at a sub-percent level, strong constraints were put on the amount of material surrounding the target and on its temperature stability. The target cell wall is made of $120\,μ$m-thick Kapton, while the beam entrance and exit windows are made of $125\,μ$m-thick aluminized Kapton. The side exit windows are made of Mylar laminated on aramid fabric with an areal density of $368\,$g/m$^2$. The target system was successfully operated during a commissioning run at PSI at the end of 2018. The target temperature was stable at the 0.01 K level. This suggests a density stability at the $0.02\,$% level, which is about a factor of ten better than required.
△ Less
Submitted 5 July, 2019;
originally announced July 2019.