-
Benefits of bolometer Joule step** and Joule pulsing
Authors:
Samantha Lynn Stever,
François Couchot,
Valentin Sauvage,
Noël Coron
Abstract:
We introduce the `Joule step**' technique, whereupon a constantly-biased bolometer has its bias voltage modified by a small additional step. We demonstrate this technique using a composite NTD semiconductor bolometer and a pulsing device which sends an extra step in voltage. We demonstrate the results of the technique over a range of bias voltages at 100, 200, and 300 mK. We find that Joule step…
▽ More
We introduce the `Joule step**' technique, whereupon a constantly-biased bolometer has its bias voltage modified by a small additional step. We demonstrate this technique using a composite NTD semiconductor bolometer and a pulsing device which sends an extra step in voltage. We demonstrate the results of the technique over a range of bias voltages at 100, 200, and 300 mK. We find that Joule step** allows us to directly measure long thermal tails with low amplitudes in the bolometer response, and could be a useful tool for quickly and easily understanding response functions of bolometric detectors. We also show that the derivative of the Joule step is equivalent to the bolometer response to a $δ$-pulse (or Joule pulse), which allows for greater understanding of fast transient behaviour.
△ Less
Submitted 8 December, 2019;
originally announced December 2019.
-
A new pulse shape description for $α$ particle pulses in a highly-sensitive sub-Kelvin bolometer
Authors:
S. L. Stever,
F. Couchot,
N. Coron,
R. M. J. Janssen,
B. Maffei
Abstract:
The next generation of cosmology space missions will be sensitive to parasitic signals arising from cosmic rays. Using a composite bolometer, we have investigated pulses produced by $α$ particles in order to understand the movement of energy produced by ionising radiation. Using a series of measurements at 100 mK, we have compared the typical fitting algorithm (a mathematical model) with a second…
▽ More
The next generation of cosmology space missions will be sensitive to parasitic signals arising from cosmic rays. Using a composite bolometer, we have investigated pulses produced by $α$ particles in order to understand the movement of energy produced by ionising radiation. Using a series of measurements at 100 mK, we have compared the typical fitting algorithm (a mathematical model) with a second method of pulse interpretation by convolving the detector's thermal response function with a starting profile of thermalised athermal phonons, taking into account the effects of heat propagation. Using this new fitting method, we have eliminated the need for a non-physical quadratic nonlinearity factor produced using more common methods, and we find a pulse form in good agreement with known aspects of thermal physics. This work is carried forward in the effort to produce a physical model for energy deposition in this detector. The modelling is motivated by the reproduction of statistical features in the experimental dataset, and the new interpretation of $α$ pulse shapes represents an improvement in the current understanding of the energy propagation mechanisms in this detector.
△ Less
Submitted 25 July, 2018;
originally announced July 2018.
-
Development of $^{100}$Mo-containing scintillating bolometers for a high-sensitivity neutrinoless double-beta decay search
Authors:
E. Armengaud,
C. Augier,
A. S. Barabash,
J. W. Beeman,
T. B. Bekker,
F. Bellini,
A. Benoît,
L. Bergé,
T. Bergmann,
J. Billard,
R. S. Boiko,
A. Broniatowski,
V. Brudanin,
P. Camus,
S. Capelli,
L. Cardani,
N. Casali,
A. Cazes,
M. Chapellier,
F. Charlieux,
D. M. Chernyak,
M. de Combarieu,
N. Coron,
F. A. Danevich,
I. Dafinei
, et al. (77 additional authors not shown)
Abstract:
This paper reports on the development of a technology involving $^{100}$Mo-enriched scintillating bolometers, compatible with the goals of CUPID, a proposed next-generation bolometric experiment to search for neutrinoless double-beta decay. Large mass ($\sim$1~kg), high optical quality, radiopure $^{100}$Mo-containing zinc and lithium molybdate crystals have been produced and used to develop high…
▽ More
This paper reports on the development of a technology involving $^{100}$Mo-enriched scintillating bolometers, compatible with the goals of CUPID, a proposed next-generation bolometric experiment to search for neutrinoless double-beta decay. Large mass ($\sim$1~kg), high optical quality, radiopure $^{100}$Mo-containing zinc and lithium molybdate crystals have been produced and used to develop high performance single detector modules based on 0.2--0.4~kg scintillating bolometers. In particular, the energy resolution of the lithium molybdate detectors near the $Q$-value of the double-beta transition of $^{100}$Mo (3034~keV) is 4--6~keV FWHM. The rejection of the $α$-induced dominant background above 2.6~MeV is better than 8$σ$. Less than 10~$μ$Bq/kg activity of $^{232}$Th ($^{228}$Th) and $^{226}$Ra in the crystals is ensured by boule recrystallization. The potential of $^{100}$Mo-enriched scintillating bolometers to perform high sensitivity double-beta decay searches has been demonstrated with only 10~kg$\times$d exposure: the two neutrino double-beta decay half-life of $^{100}$Mo has been measured with the up-to-date highest accuracy as $T_{1/2}$ = [6.90 $\pm$ 0.15(stat.) $\pm$ 0.37(syst.)] $\times$ 10$^{18}$~yr. Both crystallization and detector technologies favor lithium molybdate, which has been selected for the ongoing construction of the CUPID-0/Mo demonstrator, containing several kg of $^{100}$Mo.
△ Less
Submitted 4 October, 2017; v1 submitted 6 April, 2017;
originally announced April 2017.
-
LUMINEU: a search for neutrinoless double beta decay based on ZnMoO$_4$ scintillating bolometers
Authors:
E. Armengaud,
Q. Arnaud,
C. Augier,
A. Benoit,
A. Benoit,
L. Berge,
R. S. Boiko,
T. Bergmann,
J. Blumer,
A. Broniatowski,
V. Brudanin,
P. Camus,
A. Cazes,
M. Chapellier,
F. Charlieux,
D. M. Chernyak,
N. Coron,
P. Coulter,
F. A. Danevich,
T. de Boissiere,
R. Decourt,
M. De Jesus,
L. Devoyon,
A. -A. Drillien,
L. Dumoulin
, et al. (69 additional authors not shown)
Abstract:
The LUMINEU is designed to investigate the possibility to search for neutrinoless double beta decay in $^{100}$Mo by means of a large array of scintillating bolometers based on ZnMoO$_4$ crystals enriched in $^{100}$Mo. High energy resolution and relatively fast detectors, which are able to measure both the light and the heat generated upon the interaction of a particle in a crystal, are very prom…
▽ More
The LUMINEU is designed to investigate the possibility to search for neutrinoless double beta decay in $^{100}$Mo by means of a large array of scintillating bolometers based on ZnMoO$_4$ crystals enriched in $^{100}$Mo. High energy resolution and relatively fast detectors, which are able to measure both the light and the heat generated upon the interaction of a particle in a crystal, are very promising for the recognition and rejection of background events. We present the LUMINEU concepts and the experimental results achieved aboveground and underground with large-mass natural and enriched crystals. The measured energy resolution, the $α/β$ discrimination power and the radioactive internal contamination are all within the specifications for the projected final LUMINEU sensitivity. Simulations and preliminary results confirm that the LUMINEU technology can reach zero background in the region of interest (around 3 MeV) with exposures of the order of hundreds kg$\times$years, setting the bases for a next generation $0\nu2β$ decay experiment capable to explore the inverted hierarchy region of the neutrino mass pattern.
△ Less
Submitted 19 January, 2016;
originally announced January 2016.
-
Proceedings of the third French-Ukrainian workshop on the instrumentation developments for HEP
Authors:
F. Alessio,
S. Ya. Barsuk,
L. Berge,
O. A. Bezshyyko,
R. S. Boiko,
I. Chaikovska,
M. Chapellier,
G. Charles,
A. Chaus,
R. Chehab,
D. M. Chernyak,
N. Coron,
F. A. Danevich,
N. Delerue,
L. Devoyon,
A. -A. Drillien,
L. Dumoulin,
C. Enss,
O. Fedorchuk,
A. Fleischmann,
L. Gastaldo,
A. Giuliani,
D. Gray,
M. Gros,
S. Herve
, et al. (48 additional authors not shown)
Abstract:
The reports collected in these proceedings have been presented in the third French-Ukrainian workshop on the instrumentation developments for high-energy physics held at LAL, Orsay on October 15-16. The workshop was conducted in the scope of the IDEATE International Associated Laboratory (LIA). Joint developments between French and Ukrainian laboratories and universities as well as new proposals h…
▽ More
The reports collected in these proceedings have been presented in the third French-Ukrainian workshop on the instrumentation developments for high-energy physics held at LAL, Orsay on October 15-16. The workshop was conducted in the scope of the IDEATE International Associated Laboratory (LIA). Joint developments between French and Ukrainian laboratories and universities as well as new proposals have been discussed. The main topics of the papers presented in the Proceedings are developments for accelerator and beam monitoring, detector developments, joint developments for large-scale high-energy and astroparticle physics projects, medical applications.
△ Less
Submitted 23 December, 2015;
originally announced December 2015.
-
Scintillating bolometers based on ZnMoO$_4$ and Zn$^{100}$MoO$_4$ crystals to search for 0$ν$2$β$ decay of $^{100}$Mo (LUMINEU project): first tests at the Modane Underground Laboratory
Authors:
D. V. Poda,
E. Armengaud,
Q. Arnaud,
C. Augier,
A. Benoît,
A. Benoît,
L. Bergé,
R. S. Boiko,
T. Bergmann,
J. Blümer,
A. Broniatowski,
V. Brudanin,
P. Camus,
A. Cazes,
B. Censier,
M. Chapellier,
F. Charlieux,
D. M. Chernyak,
N. Coron,
P. Coulter,
G. A. Cox,
F. A. Danevich,
T. de Boissière,
R. Decourt,
M. De Jesus
, et al. (69 additional authors not shown)
Abstract:
The technology of scintillating bolometers based on zinc molybdate (ZnMoO$_4$) crystals is under development within the LUMINEU project to search for 0$ν$2$β$ decay of $^{100}$Mo with the goal to set the basis for large scale experiments capable to explore the inverted hierarchy region of the neutrino mass pattern. Advanced ZnMoO$_4$ crystal scintillators with mass of $\sim$~0.3 kg were developed…
▽ More
The technology of scintillating bolometers based on zinc molybdate (ZnMoO$_4$) crystals is under development within the LUMINEU project to search for 0$ν$2$β$ decay of $^{100}$Mo with the goal to set the basis for large scale experiments capable to explore the inverted hierarchy region of the neutrino mass pattern. Advanced ZnMoO$_4$ crystal scintillators with mass of $\sim$~0.3 kg were developed and Zn$^{100}$MoO$_4$ crystal from enriched $^{100}$Mo was produced for the first time by using the low-thermal-gradient Czochralski technique. One ZnMoO$_4$ scintillator and two samples (59 g and 63 g) cut from the enriched boule were tested aboveground at milli-Kelvin temperature as scintillating bolometers showing a high detection performance. The first results of the low background measurements with three ZnMoO$_4$ and two enriched detectors installed in the EDELWEISS set-up at the Modane Underground Laboratory (France) are presented.
△ Less
Submitted 4 February, 2015;
originally announced February 2015.
-
Aboveground test of an advanced Li$_2$MoO$_4$ scintillating bolometer to search for neutrinoless double beta decay of $^{100}$Mo
Authors:
T. B. Bekker,
N. Coron,
F. A. Danevich,
V. Ya. Degoda,
A. Giuliani,
V. D. Grigorieva,
N. V. Ivannikova,
M. Mancuso,
P. de Marcillac,
I. M. Moroz,
C. Nones,
E. Olivieri,
G. Pessina,
D. V. Poda,
V. N. Shlegel,
V. I. Tretyak,
M. Velazquez
Abstract:
Large lithium molybdate (Li$_2$MoO$_4$) crystal boules were produced by using the low thermal gradient Czochralski growth technique from deeply purified molybdenum. A small sample from one of the boules was preliminary characterized in terms of X-ray-induced and thermally-excited luminescence. A large cylindrical crystalline element (with a size of $\oslash 40\times40$ mm) was used to fabricate a…
▽ More
Large lithium molybdate (Li$_2$MoO$_4$) crystal boules were produced by using the low thermal gradient Czochralski growth technique from deeply purified molybdenum. A small sample from one of the boules was preliminary characterized in terms of X-ray-induced and thermally-excited luminescence. A large cylindrical crystalline element (with a size of $\oslash 40\times40$ mm) was used to fabricate a scintillating bolometer, which was operated aboveground at $\sim 15$ mK by using a pulse-tube cryostat housing a high-power dilution refrigerator. The excellent detector performance in terms of energy resolution and $α$ background suppression along with preliminary positive indications on the radiopurity of this material show the potentiality of Li$_2$MoO$_4$ scintillating bolometers for low-counting experiment to search for neutrinoless double beta decay of $^{100}$Mo.
△ Less
Submitted 17 December, 2014; v1 submitted 25 October, 2014;
originally announced October 2014.
-
Impact of particles on the Planck HFI detectors: Ground-based measurements and physical interpretation
Authors:
A. Catalano,
P. Ade,
Y. Atik,
A. Benoit,
E. Bréele,
J. J. Bock,
P. Camus,
M. Chabot,
M. Charra,
B. P. Crill,
N. Coron,
A. Coulais,
F. -X. Désert,
L. Fauvet,
Y. Giraud-Héraud,
O. Guillaudin,
W. Holmes,
W. C. Jones,
J. -M. Lamarre,
J. Macías-Pérez,
M. Martinez,
A. Miniussi,
A. Monfardini,
F. Pajot,
G. Patanchon
, et al. (9 additional authors not shown)
Abstract:
The Planck High Frequency Instrument (HFI) surveyed the sky continuously from August 2009 to January 2012. Its noise and sensitivity performance were excellent, but the rate of cosmic ray impacts on the HFI detectors was unexpectedly high. Furthermore, collisions of cosmic rays with the focal plane produced transient signals in the data (glitches) with a wide range of characteristics. A study of c…
▽ More
The Planck High Frequency Instrument (HFI) surveyed the sky continuously from August 2009 to January 2012. Its noise and sensitivity performance were excellent, but the rate of cosmic ray impacts on the HFI detectors was unexpectedly high. Furthermore, collisions of cosmic rays with the focal plane produced transient signals in the data (glitches) with a wide range of characteristics. A study of cosmic ray impacts on the HFI detector modules has been undertaken to categorize and characterize the glitches, to correct the HFI time-ordered data, and understand the residual effects on Planck maps and data products. This paper presents an evaluation of the physical origins of glitches observed by the HFI detectors. In order to better understand the glitches observed by HFI in flight, several ground-based experiments were conducted with flight-spare HFI bolometer modules. The experiments were conducted between 2010 and 2013 with HFI test bolometers in different configurations using varying particles and impact energies. The bolometer modules were exposed to 23 MeV protons from the Orsay IPN TANDEM accelerator, and to $^{241}$Am and $^{244}$Cm $α$-particle and $^{55}$Fe radioactive X-ray sources. The calibration data from the HFI ground-based preflight tests were used to further characterize the glitches and compare glitch rates with statistical expectations under laboratory conditions. Test results provide strong evidence that the dominant family of glitches observed in flight are due to cosmic ray absorption by the silicon die substrate on which the HFI detectors reside. Glitch energy is propagated to the thermistor by ballistic phonons, while there is also a thermal diffusion contribution. The implications of these results for future satellite missions, especially those in the far-infrared to sub-millimetre and millimetre regions of the electromagnetic spectrum, are discussed.
△ Less
Submitted 2 September, 2014; v1 submitted 26 March, 2014;
originally announced March 2014.
-
Characterization and Physical Explanation of Energetic Particles on Planck HFI Instrument
Authors:
A. Catalano,
P. Ade,
Y. Atik,
A. Benoit,
E. Bréele,
J. J. Bock,
P. Camus,
M. Charra,
B. P. Crill,
N. Coron,
A. Coulais,
F. -X. Désert,
L. Fauvet,
Y. Giraud-Héraud,
O. Guillaudin,
W. Holmes,
W. C. Jones,
J. -M. Lamarre,
J. Macías-Pérez,
M. Martinez,
A. Miniussi,
A. Monfardini,
F. Pajot,
G. Patanchon,
A. Pelissier
, et al. (8 additional authors not shown)
Abstract:
The Planck High Frequency Instrument (HFI) has been surveying the sky continuously from the second Lagrangian point (L2) between August 2009 and January 2012. It operates with 52 high impedance bolometers cooled at 100mK in a range of frequency between 100 GHz and 1THz with unprecedented sensivity, but strong coupling with cosmic radiation. At L2, the particle flux is about 5 $cm^{-2} s^{-1}$ and…
▽ More
The Planck High Frequency Instrument (HFI) has been surveying the sky continuously from the second Lagrangian point (L2) between August 2009 and January 2012. It operates with 52 high impedance bolometers cooled at 100mK in a range of frequency between 100 GHz and 1THz with unprecedented sensivity, but strong coupling with cosmic radiation. At L2, the particle flux is about 5 $cm^{-2} s^{-1}$ and is dominated by protons incident on the spacecraft. Protons with an energy above 40MeV can penetrate the focal plane unit box causing two different effects: glitches in the raw data from direct interaction of cosmic rays with detectors (producing a data loss of about 15% at the end of the mission) and thermal drifts in the bolometer plate at 100mK adding non-gaussian noise at frequencies below 0.1Hz. The HFI consortium has made strong efforts in order to correct for this effect on the time ordered data and final Planck maps. This work intends to give a view of the physical explanation of the glitches observed in the HFI instrument in-flight. To reach this goal, we performed several ground-based experiments using protons and $α$ particles to test the impact of particles on the HFI spare bolometers with a better control of the environmental conditions with respect to the in-flight data. We have shown that the dominant part of glitches observed in the data comes from the impact of cosmic rays in the silicon die frame supporting the micro-machinced bolometric detectors propagating energy mainly by ballistic phonons and by thermal diffusion. The implications of these results for future satellite missions will be discussed.
△ Less
Submitted 22 March, 2014;
originally announced March 2014.
-
Purification of molybdenum oxide, growth and characterization of medium size zinc molybdate crystals for the LUMINEU program
Authors:
V. N. Shlegel,
L. Berge,
R. S. Boiko,
M. Chapellier,
D. M. Chernyak,
N. Coron,
F. A. Danevich,
R. Decourt,
V. Ya. Degoda,
L. Devoyon,
A. Drillien,
L. Dumoulin,
C. Enss,
A. Fleischmann,
L. Gastaldo,
A. Giuliani,
M. Gros,
S. Herve,
I. M. Ivanov,
V. V. Kobychev,
Ya. P. Kogut,
F. Koskas,
M. Loidl,
P. Magnier,
E. P. Makarov
, et al. (23 additional authors not shown)
Abstract:
The LUMINEU program aims at performing a pilot experiment on neutrinoless double beta decay of 100Mo using radiopure ZnMoO4 crystals operated as scintillating bolometers. Growth of high quality radiopure crystals is a complex task, since there are no commercially available molybdenum compounds with the required levels of purity and radioactive contamination. This paper discusses approaches to puri…
▽ More
The LUMINEU program aims at performing a pilot experiment on neutrinoless double beta decay of 100Mo using radiopure ZnMoO4 crystals operated as scintillating bolometers. Growth of high quality radiopure crystals is a complex task, since there are no commercially available molybdenum compounds with the required levels of purity and radioactive contamination. This paper discusses approaches to purify molybdenum and synthesize compound for high quality radiopure ZnMoO4 crystal growth. A combination of a double sublimation (with addition of zinc molybdate) with subsequent recrystallization in aqueous solutions (using zinc molybdate as a collector) was used. Zinc molybdate crystals up to 1.5 kg were grown by the low-thermal-gradient Czochralski technique, their optical, luminescent, diamagnetic, thermal and bolometric properties were tested.
△ Less
Submitted 12 December, 2013;
originally announced December 2013.
-
Proceedings of the 1st International Workshop "Radiopure Scintillators for EURECA" (RPScint'2008)
Authors:
E. Armengau,
M. Bauer,
I. Bavykina,
A. Benoit,
A. Bento,
J. Blumer,
L. Bornschein,
A. Broniatowski,
G. Burghart,
P. Camus,
A. Chantelauze,
M. Chapellier,
G. Chardin,
C. Ciemniak,
C. Coppi,
N. Coron,
O. Crauste,
F. A. Danevich,
E. Daw,
X. Defay,
M. De Jesus,
P. de Marcillac,
G. Deuter,
J. Domange,
P. Di Stefano
, et al. (34 additional authors not shown)
Abstract:
Workshop RPSCINT'2008 was organized in Kyiv (Ukraine) on 9th and 10th September 2008. The idea was to bring together physicists, chemists, crystal scintillator experts and manufacturers to discuss the requirements of low-count rate experiments, in particular the required radiopurity and scintillation properties; selection and screening of input materials; purification of materials; raw compound…
▽ More
Workshop RPSCINT'2008 was organized in Kyiv (Ukraine) on 9th and 10th September 2008. The idea was to bring together physicists, chemists, crystal scintillator experts and manufacturers to discuss the requirements of low-count rate experiments, in particular the required radiopurity and scintillation properties; selection and screening of input materials; purification of materials; raw compound preparation; crystal growing, annealing and handling; test of crystals; search for and development of new scintillating materials. Some contributions to the RPSCINT 2008 workshop are presented in these proceedings.
△ Less
Submitted 9 March, 2009; v1 submitted 9 March, 2009;
originally announced March 2009.
-
The ROSEBUD experiment at Canfranc: 2001 report
Authors:
S. Cebrian,
N. Coron,
G. Dambier,
E. Garcia,
I. G. Irastorza,
J. Leblanc,
P. de Marcillac,
A. Morales,
J. Morales,
A. Ortiz de Solorzano,
J. Puimedon,
M. L. Sarsa,
J. A. Villar
Abstract:
The ROSEBUD experiment for Direct Dark Matter detection settled in 1999 in the Canfranc Underground Laboratory. The first phase of the experiment was dedicated to the understanding and reduction of the radioactive background following successive removals of the radioimpure materials. Sapphire (25g, 50g) and germanium (67g) absorbers were used. Thresholds respectively lower than 1keV and 450 eV w…
▽ More
The ROSEBUD experiment for Direct Dark Matter detection settled in 1999 in the Canfranc Underground Laboratory. The first phase of the experiment was dedicated to the understanding and reduction of the radioactive background following successive removals of the radioimpure materials. Sapphire (25g, 50g) and germanium (67g) absorbers were used. Thresholds respectively lower than 1keV and 450 eV were achieved on these detectors. The second phase of the experiment plans to use scintillating bolometers to discriminate between recoiling nuclei and electrons. Prototypes using commercial CaWO4 (54g) and BGO (46g) were designed for this purpose. While internal contamination was found and identified in both targets, neutron calibrations revealed their high discrimination power. A 6 keV threshold on the heat channel of the BGO bolometer points out the interest of such a novel material, for Dark Matter research on neutralinos having spin-dependent or spin-independent interactions.
△ Less
Submitted 3 January, 2002; v1 submitted 12 December, 2001;
originally announced December 2001.
-
The Diabolo photometer and the future of ground-based millimetric bolometer devices
Authors:
F. -X. Desert,
A. Benoit,
Ph. Camus,
M. Giard,
E. Pointecouteau,
N. Aghanim,
J. -Ph. Bernard,
N. Coron,
J. -M. Lamarre,
Ph. Marty,
J. Delabrouille,
V. Soglasnova
Abstract:
The millimetric atmospheric windows at 1 and 2 mm are interesting targets for cosmological studies. Two broad areas appear leading this field: 1) the search for high redshift star-forming galaxies and 2) the measurement of Sunyaev-Zel'dovich (SZ) effect in clusters of galaxies at all redshifts. The Diabolo photometer is a dual-channel photometer working at 1.2 and 2.1 mm and dedicated to high an…
▽ More
The millimetric atmospheric windows at 1 and 2 mm are interesting targets for cosmological studies. Two broad areas appear leading this field: 1) the search for high redshift star-forming galaxies and 2) the measurement of Sunyaev-Zel'dovich (SZ) effect in clusters of galaxies at all redshifts. The Diabolo photometer is a dual-channel photometer working at 1.2 and 2.1 mm and dedicated to high angular resolution measurements of the Sunyaev--Zel'dovich effect towards distant clusters. It uses 2 by 3 bolometers cooled down to 0.1 K with a compact open dilution cryostat. The high resolution is provided by the IRAM 30 m telescope. The result of several Winter campaigns are reported here, including the first millimetric map of the SZ effect that was obtained by Pointecouteau et al. (2001) on RXJ1347-1145, the non-detection of a millimetric counterpart to the radio decrement towards PC1643+4631 and 2 mm number count upper limits. We discuss limitations in ground-based single-dish millimetre observations, namely sky noise and the number of detectors. We advocate the use of fully sampled arrays of (100 to 1000) bolometers as a big step forward in the millimetre continuum science. Efforts in France are briefly mentionned.
△ Less
Submitted 1 December, 2001;
originally announced December 2001.
-
Extended SZ map of the most luminous X-ray cluster, RXJ1347-1145
Authors:
E. Pointecouteau,
M. Giard,
F. X. Désert,
B. Alain,
J. P. Bernard,
J. M. Lamarre,
N. Coron
Abstract:
We present in this letter a high resolution (22'' FWHM) extended map at 2.1mm of the Sunyaev-Zel'dovich effect toward the most luminous X-ray cluster, RXJ1347-1145. These observations have been performed with the DIABOLO photometer working at the focus of the 30m IRAM radiotelescope. We have derived a projected gas mass of $(1.1 \pm 0.1)\times 10^{14} h_{50}^{-5/2}$M$_{\odot}$ within an angular…
▽ More
We present in this letter a high resolution (22'' FWHM) extended map at 2.1mm of the Sunyaev-Zel'dovich effect toward the most luminous X-ray cluster, RXJ1347-1145. These observations have been performed with the DIABOLO photometer working at the focus of the 30m IRAM radiotelescope. We have derived a projected gas mass of $(1.1 \pm 0.1)\times 10^{14} h_{50}^{-5/2}$M$_{\odot}$ within an angular radius of $θ=74''$ (ie: projected radius of 0.6Mpc, $H_{0}=50$km/s/Mpc, $Ω_m=0.3$, $Ω_Λ=0.7$). This result matches very well the expected gas mass from the cluster models of X-ray data. With an unprecedented sensitivity level our measurement does not show significant departure from a spherical distribution. The data analysis also allows us to characterize the 2.1mm flux of a well known radio source lying in the center of the cluster: $F_{RS}(2.1\textrm{mm})=5.7\pm 1.6$mJy.
△ Less
Submitted 13 December, 2000;
originally announced December 2000.
-
First results of the ROSEBUD Dark Matter experiment
Authors:
S. Cebrian,
N. Coron,
G. Dambier,
E. Garcia,
D. Gonzalez,
I. G. Irastorza,
J. Leblanc,
P. de Marcillac,
A. Morales,
J. Morales,
A. Ortiz de Solorzano,
A. Peruzzi,
J. Puimedon,
M. L. Sarsa,
S. Scopel,
J. A. Villar
Abstract:
Rare Objects SEarch with Bolometers UndergrounD) is an experiment which attempts to detect low mass Weak Interacting Massive Particles (WIMPs) through their elastic scattering off Al and O nuclei. It consists of three small sapphire bolometers (of a total mass of 100 g) with NTD-Ge sensors in a dilution refrigerator operating at 20 mK in the Canfranc Underground Laboratory. We report in this pap…
▽ More
Rare Objects SEarch with Bolometers UndergrounD) is an experiment which attempts to detect low mass Weak Interacting Massive Particles (WIMPs) through their elastic scattering off Al and O nuclei. It consists of three small sapphire bolometers (of a total mass of 100 g) with NTD-Ge sensors in a dilution refrigerator operating at 20 mK in the Canfranc Underground Laboratory. We report in this paper the results of several runs (of about 10 days each) with successively improved energy thresholds, and the progressive background reduction obtained by improvement of the radiopurity of the components and subsequent modifications in the experimental assembly, including the addition of old lead shields. Mid-term plans and perspectives of the experiment are also presented.
△ Less
Submitted 20 April, 2000;
originally announced April 2000.
-
Calibration and First light of the Diabolo photometer at the Millimetre and Infrared Testa Grigia Observatory
Authors:
A. Benoit,
F. Zagury,
N. Coron,
M. De Petris,
F. -X. Desert,
M. Giard,
J. -P. Bernard,
J. -P. Crussaire,
G. Dambier,
P. de Bernardis,
J. Delabrouille,
A. De Luca,
P. de Marcillac,
G. Jegoudez,
J. -M. Lamarre,
J. Leblanc,
J. -P. Lepeltier,
B. Leriche,
G. Mainella,
J. Narbonne,
F. Pajot,
R. Pons,
J. -L. Puget,
S. Pujol,
G. Recouvreur
, et al. (4 additional authors not shown)
Abstract:
We have designed and built a large-throughput dual channel photometer,
Diabolo. This photometer is dedicated to the observation of millimetre continuum diffuse sources, and in particular, of the Sunyaev-Zel'dovich effect and of anisotropies of the 3K background. We describe the optical layout and filtering system of the instrument, which uses two bolometric detectors for simultaneous observati…
▽ More
We have designed and built a large-throughput dual channel photometer,
Diabolo. This photometer is dedicated to the observation of millimetre continuum diffuse sources, and in particular, of the Sunyaev-Zel'dovich effect and of anisotropies of the 3K background. We describe the optical layout and filtering system of the instrument, which uses two bolometric detectors for simultaneous observations in two frequency channels at 1.2 and 2.1 mm. The bolometers are cooled to a working temperature of 0.1 K provided by a compact dilution cryostat. The photometric and angular responses of the instrument are measured in the laboratory. First astronomical light was detected in March 1995 at the focus of the new Millimetre and Infrared Testa Grigia Observatory (MITO) Telescope. The established sensitivity of the system is of 7 mK_RJ s^1/2$. For a typical map of at least 10 beams, with one hour of integration per beam, one can achieve the rms values of y_SZ ~ 7 10^-5 and the 3K background anisotropy Delta T/T ~ 7 10^-5, in winter conditions. We also report on a novel bolometer AC readout circuit which allows for the first time total power measurements on the sky. This technique alleviates (but does not forbid) the use of chop** with a secondary mirror. This technique and the dilution fridge concept will be used in future scan--modulated space instrument like the ESA Planck mission project.
△ Less
Submitted 17 December, 1999;
originally announced December 1999.
-
A Sunyaev-Zel'dovich map of the massive core in the luminous X-ray cluster RXJ1347-1145
Authors:
E. Pointecouteau,
M. Giard,
A. Benoit,
F. X. Désert,
N. Aghanim,
N. Coron,
J. M. Lamarre,
J. Delabrouille
Abstract:
We have mapped the Sunyaev-Zel'dovich decrement (hereafter SZ) in the direction of the most luminous X-ray cluster known to date, RXJ1347-1145, at z=0.451. This has been achieved with an angular resolution of about 23'' using the Diabolo photometer running on the IRAM 30 meter radio telescope. We present here a map of the cluster central region at 2.1mm. The Comptonization parameter towards the…
▽ More
We have mapped the Sunyaev-Zel'dovich decrement (hereafter SZ) in the direction of the most luminous X-ray cluster known to date, RXJ1347-1145, at z=0.451. This has been achieved with an angular resolution of about 23'' using the Diabolo photometer running on the IRAM 30 meter radio telescope. We present here a map of the cluster central region at 2.1mm. The Comptonization parameter towards the cluster center, $\yc=(12.7^{+2.9}_{-3.1})\times 10^{-4}$, corresponds to the deepest SZ decrement ever observed. Using the gas density distribution derived from X-ray data, this measurement implies a gas temperature $\te=16.2 \pm 3.8$ keV. The resulting total mass of the cluster is, under hydrostatic equilibrium, $M(r<1 Mpc)=(1.0 \pm 0.3) \times 10^{15} M_\odot$ for a corresponding gas fraction $f_{gas}(r<1 Mpc)=(19.5 \pm 5.8)%$.
△ Less
Submitted 12 May, 1999;
originally announced May 1999.
-
Observations of the Sunyaev-Zel'dovich effect at high angular resolution towards the galaxy clusters A665, A2163 and CL0016+16
Authors:
F. -X. Desert,
A. Benoit,
S. Gaertner,
J. -P. Bernard,
N. Coron,
J. Delabrouille,
P. de Marcillac,
M. Giard,
J. -M. Lamarre,
B. Lefloch,
J. -L. Puget,
A. Sirbi
Abstract:
We report on the first observation of the Sunyaev-Zel'dovich effect with the Diabolo experiment at the IRAM 30 metre telescope. A significant brightness decrement is detected in the direction of three clusters (Abell 665, Abell 2163 and CL0016+16). With a 30 arcsecond beam and 3 arcminute beamthrow, this is the highest angular resolution observation to date of the SZ effect.
We report on the first observation of the Sunyaev-Zel'dovich effect with the Diabolo experiment at the IRAM 30 metre telescope. A significant brightness decrement is detected in the direction of three clusters (Abell 665, Abell 2163 and CL0016+16). With a 30 arcsecond beam and 3 arcminute beamthrow, this is the highest angular resolution observation to date of the SZ effect.
△ Less
Submitted 24 August, 1998;
originally announced August 1998.
-
First measurement of the submillimetre Sunyaev-Zel'dovich effect
Authors:
J. -M. Lamarre,
M. Giard,
E. Pointecouteau,
J. -P. Bernard,
G. Serra,
F. Pajot,
F. -X. Desert,
I. Ristorcelli,
J. -P. Torre,
S. Church,
N. Coron,
J. -L. Puget,
J. J. Bock
Abstract:
We report the first detection of the Sunyaev-Zel'dovich increment on the cosmic microwave background (CMB) at submillimetre wavelengths in the direction of a cluster of galaxies.It was achieved towards the rich cluster Abell 2163, using the PRONAOS 2-metre stratospheric telescope. Together with data from the SuZIE, Diabolo, and ISO-PHT experiments, these measurements, for the first time, give a…
▽ More
We report the first detection of the Sunyaev-Zel'dovich increment on the cosmic microwave background (CMB) at submillimetre wavelengths in the direction of a cluster of galaxies.It was achieved towards the rich cluster Abell 2163, using the PRONAOS 2-metre stratospheric telescope. Together with data from the SuZIE, Diabolo, and ISO-PHT experiments, these measurements, for the first time, give a complete picture of the far-infrared to millimetre spectral energy distribution of the diffuse emission toward a cluster of galaxies. It clearly shows the positive and negative parts of the S.Z. effect and also a positive signal at short wavelengths that can be attributed to foreground dust in our galaxy.
△ Less
Submitted 3 September, 1998; v1 submitted 9 June, 1998;
originally announced June 1998.