Skip to main content

Showing 1–11 of 11 results for author: Cornelissen, S

.
  1. AngioMoCo: Learning-based Motion Correction in Cerebral Digital Subtraction Angiography

    Authors: Ruisheng Su, Matthijs van der Sluijs, Sandra Cornelissen, Wim van Zwam, Aad van der Lugt, Wiro Niessen, Danny Ruijters, Theo van Walsum, Adrian Dalca

    Abstract: Cerebral X-ray digital subtraction angiography (DSA) is the standard imaging technique for visualizing blood flow and guiding endovascular treatments. The quality of DSA is often negatively impacted by body motion during acquisition, leading to decreased diagnostic value. Time-consuming iterative methods address motion correction based on non-rigid registration, and employ sparse key points and no… ▽ More

    Submitted 9 October, 2023; originally announced October 2023.

  2. arXiv:2308.16139  [pdf, other

    cs.CV cs.DB cs.LG

    MedShapeNet -- A Large-Scale Dataset of 3D Medical Shapes for Computer Vision

    Authors: Jianning Li, Zongwei Zhou, Jiancheng Yang, Antonio Pepe, Christina Gsaxner, Gijs Luijten, Chongyu Qu, Tiezheng Zhang, Xiaoxi Chen, Wenxuan Li, Marek Wodzinski, Paul Friedrich, Kangxian Xie, Yuan **, Narmada Ambigapathy, Enrico Nasca, Naida Solak, Gian Marco Melito, Viet Duc Vu, Afaque R. Memon, Christopher Schlachta, Sandrine De Ribaupierre, Rajnikant Patel, Roy Eagleson, Xiaojun Chen , et al. (132 additional authors not shown)

    Abstract: Prior to the deep learning era, shape was commonly used to describe the objects. Nowadays, state-of-the-art (SOTA) algorithms in medical imaging are predominantly diverging from computer vision, where voxel grids, meshes, point clouds, and implicit surface models are used. This is seen from numerous shape-related publications in premier vision conferences as well as the growing popularity of Shape… ▽ More

    Submitted 12 December, 2023; v1 submitted 30 August, 2023; originally announced August 2023.

    Comments: 16 pages

    MSC Class: 68T01

  3. arXiv:2305.07894  [pdf, other

    cs.CE cs.CV cs.LG

    Voxel-wise classification for porosity investigation of additive manufactured parts with 3D unsupervised and (deeply) supervised neural networks

    Authors: Domenico Iuso, Soumick Chatterjee, Sven Cornelissen, Dries Verhees, Jan De Beenhouwer, Jan Sijbers

    Abstract: Additive Manufacturing (AM) has emerged as a manufacturing process that allows the direct production of samples from digital models. To ensure that quality standards are met in all manufactured samples of a batch, X-ray computed tomography (X-CT) is often used combined with automated anomaly detection. For the latter, deep learning (DL) anomaly detection techniques are increasingly, as they can be… ▽ More

    Submitted 9 June, 2023; v1 submitted 13 May, 2023; originally announced May 2023.

  4. CAVE: Cerebral Artery-Vein Segmentation in Digital Subtraction Angiography

    Authors: Ruisheng Su, P. Matthijs van der Sluijs, Yuan Chen, Sandra Cornelissen, Ruben van den Broek, Wim H. van Zwam, Aad van der Lugt, Wiro Niessen, Danny Ruijters, Theo van Walsum

    Abstract: Cerebral X-ray digital subtraction angiography (DSA) is a widely used imaging technique in patients with neurovascular disease, allowing for vessel and flow visualization with high spatio-temporal resolution. Automatic artery-vein segmentation in DSA plays a fundamental role in vascular analysis with quantitative biomarker extraction, facilitating a wide range of clinical applications. The widely… ▽ More

    Submitted 1 May, 2024; v1 submitted 3 August, 2022; originally announced August 2022.

    Comments: Published in Computerized Medical Imaging and Graphics

  5. autoTICI: Automatic Brain Tissue Reperfusion Scoring on 2D DSA Images of Acute Ischemic Stroke Patients

    Authors: Ruisheng Su, Sandra A. P. Cornelissen, Matthijs van der Sluijs, Adriaan C. G. M. van Es, Wim H. van Zwam, Diederik W. J. Dippel, Geert Lycklama, Pieter Jan van Doormaal, Wiro J. Niessen, Aad van der Lugt, Theo van Walsum

    Abstract: The Thrombolysis in Cerebral Infarction (TICI) score is an important metric for reperfusion therapy assessment in acute ischemic stroke. It is commonly used as a technical outcome measure after endovascular treatment (EVT). Existing TICI scores are defined in coarse ordinal grades based on visual inspection, leading to inter- and intra-observer variation. In this work, we present autoTICI, an auto… ▽ More

    Submitted 7 May, 2021; v1 submitted 3 October, 2020; originally announced October 2020.

    Comments: Accepted for publication in IEEE Transactions on Medical Imaging (IEEE TMI)

  6. Laboratory demonstration of a cryogenic deformable mirror for wavefront correction of space-borne infrared telescopes

    Authors: Aoi Takahashi, Keigo Enya, Kanae Haze, Hirokazu Kataza, Takayuki Kotani, Hideo Matsuhara, Tomohiro Kamiya, Tomoyasu Yamamuro, Paul Bierden, Steven Cornelissen, Charlie Lam, Michael Feinberg

    Abstract: This paper demonstrates a cryogenic deformable mirror (DM) with 1,020 actuators based on micro-electrical mechanical systems (MEMS) technology. Cryogenic space-borne infrared telescopes can experience a wavefront error due to a figure error of their mirror surface, which makes the imaging performance worse. For on-orbit wavefront correction as one solution, we developed a MEMS-processed electro-st… ▽ More

    Submitted 29 September, 2017; originally announced October 2017.

    Comments: 29 pages, 23 figures

    Journal ref: Applied Optics, Vol.56, Issue 23, pp. 6694-6708 (2017)

  7. arXiv:1202.1566  [pdf, ps, other

    astro-ph.IM

    MEMS practice, from the lab to the telescope

    Authors: Katie M. Morzinski, Andrew P. Norton, Julia Wilhelmson Evans, Layra Reza, Scott A. Severson, Daren Dillon, Marc Reinig, Donald T. Gavel, Steven Cornelissen, Bruce A. Macintosh, Claire E. Max

    Abstract: Micro-electro-mechanical systems (MEMS) technology can provide for deformable mirrors (DMs) with excellent performance within a favorable economy of scale. Large MEMS-based astronomical adaptive optics (AO) systems such as the Gemini Planet Imager are coming on-line soon. As MEMS DM end-users, we discuss our decade of practice with the micromirrors, from inspecting and characterizing devices to ev… ▽ More

    Submitted 7 February, 2012; originally announced February 2012.

    Comments: 14 pages, 15 figures, Invited Paper, SPIE Photonics West 2012

  8. arXiv:1004.5319  [pdf

    cond-mat.mtrl-sci cond-mat.mes-hall

    Direct experimental measurement of phase-amplitude coupling in spin torque oscillators

    Authors: L. Bianchini, S. Cornelissen, Joo-Von Kim, T. Devolder, W. van Roy, L. Lagae, C. Chappert

    Abstract: We study spin-torque induced oscillations of MgO magnetic tunnel junctions in the time domain. By using the Hilbert transform on the time traces, we obtain for the first time a direct experimental measure of the coupling between the power and the phase fluctuations. We deduce the power restoration rate and we obtain low values for the coupling strength, which is consistent with the weak frequency… ▽ More

    Submitted 21 July, 2010; v1 submitted 29 April, 2010; originally announced April 2010.

    Comments: 3 pages, 3 figures

    Journal ref: Appl. Phys. Lett. 97, 032502 (2010)

  9. arXiv:0907.3792  [pdf, ps, other

    cond-mat.mes-hall cond-mat.mtrl-sci

    Quantized spin wave modes in magnetic tunnel junction nanopillars

    Authors: A. Helmer, S. Cornelissen, T. Devolder, J. -V. Kim, W. van Roy, L. Lagae, C. Chappert

    Abstract: We present an experimental and theoretical study of the magnetic field dependence of the mode frequency of thermally excited spin waves in rectangular shaped nanopillars of lateral sizes 60x100, 75x150, and 105x190 nm2, patterned from MgO-based magnetic tunnel junctions. The spin wave frequencies were measured using spectrally resolved electrical noise measurements. In all spectra, several indep… ▽ More

    Submitted 8 January, 2010; v1 submitted 22 July, 2009; originally announced July 2009.

    Comments: 16 pages, 4 figures, (re)submitted to PRB

  10. arXiv:0810.1110  [pdf, ps, other

    cond-mat.mtrl-sci

    Auto-oscillation threshold and line narrowing in MgO-based spin-torque oscillators

    Authors: S. Cornelissen, L. Bianchini, G. Hrkac, M. Op de Beeck, L. Lagae, Joo-Von Kim, T. Devolder, P. Crozat, C. Chappert, T. Schrefl

    Abstract: We present an experimental study of the power spectrum of current-driven magnetization oscillations in MgO tunnel junctions under low bias. We find the existence of narrow spectral lines, down to 8 MHz in width at a frequency of 10.7 GHz, for small applied fields with clear evidence of an auto-oscillation threshold. Micromagnetics simulations indicate that the excited mode corresponds to an edge… ▽ More

    Submitted 16 September, 2009; v1 submitted 7 October, 2008; originally announced October 2008.

    Journal ref: Europhys. Lett. 87, 57001 (2009)

  11. arXiv:0810.0978  [pdf, other

    cond-mat.mtrl-sci

    Auto-oscillation threshold, narrow spectral lines, and line jitter in spin-torque oscillators based on MgO magnetic tunnel junctions

    Authors: T. Devolder, S. Cornelissen, L. Bianchini, Joo-Von Kim, P. Crozat, C. Chappert, M. Op de Beeck, L. Lagae

    Abstract: We demonstrate spin torque induced auto-oscillation in MgO-based magnetic tunnel junctions. At the generation threshold, we observe a strong line narrowing down to 6 MHz at 300K and a dramatic increase in oscillator power, yielding spectrally pure oscillations free of flicker noise. Setting the synthetic antiferromagnet into autooscillation requires the same current polarity as the one needed to… ▽ More

    Submitted 6 October, 2008; originally announced October 2008.