-
Enhancing Surgical Performance in Cardiothoracic Surgery with Innovations from Computer Vision and Artificial Intelligence: A Narrative Review
Authors:
Merryn D. Constable,
Hubert P. H. Shum,
Stephen Clark
Abstract:
When technical requirements are high, and patient outcomes are critical, opportunities for monitoring and improving surgical skills via objective motion analysis feedback may be particularly beneficial. This narrative review synthesises work on technical and non-technical surgical skills, collaborative task performance, and pose estimation to illustrate new opportunities to advance cardiothoracic…
▽ More
When technical requirements are high, and patient outcomes are critical, opportunities for monitoring and improving surgical skills via objective motion analysis feedback may be particularly beneficial. This narrative review synthesises work on technical and non-technical surgical skills, collaborative task performance, and pose estimation to illustrate new opportunities to advance cardiothoracic surgical performance with innovations from computer vision and artificial intelligence. These technological innovations are critically evaluated in terms of the benefits they could offer the cardiothoracic surgical community, and any barriers to the uptake of the technology are elaborated upon. Like some other specialities, cardiothoracic surgery has relatively few opportunities to benefit from tools with data capture technology embedded within them (as with robotic-assisted laparoscopic surgery, for example). In such cases, pose estimation techniques that allow for movement tracking across a conventional operating field without using specialist equipment or markers offer considerable potential. With video data from either simulated or real surgical procedures, these tools can (1) provide insight into the development of expertise and surgical performance over a surgeon's career, (2) provide feedback to trainee surgeons regarding areas for improvement, (3) provide the opportunity to investigate what aspects of skill may be linked to patient outcomes which can (4) inform the aspects of surgical skill which should be focused on within training or mentoring programmes. Classifier or assessment algorithms that use artificial intelligence to 'learn' what expertise is from expert surgical evaluators could further assist educators in determining if trainees meet competency thresholds.
△ Less
Submitted 17 February, 2024;
originally announced February 2024.
-
Maximising Coefficiency of Human-Robot Handovers through Reinforcement Learning
Authors:
Marta Lagomarsino,
Marta Lorenzini,
Merryn Dale Constable,
Elena De Momi,
Cristina Becchio,
Arash Ajoudani
Abstract:
Handing objects to humans is an essential capability for collaborative robots. Previous research works on human-robot handovers focus on facilitating the performance of the human partner and possibly minimising the physical effort needed to grasp the object. However, altruistic robot behaviours may result in protracted and awkward robot motions, contributing to unpleasant sensations by the human p…
▽ More
Handing objects to humans is an essential capability for collaborative robots. Previous research works on human-robot handovers focus on facilitating the performance of the human partner and possibly minimising the physical effort needed to grasp the object. However, altruistic robot behaviours may result in protracted and awkward robot motions, contributing to unpleasant sensations by the human partner and affecting perceived safety and social acceptance. This paper investigates whether transferring the cognitive science principle that "humans act coefficiently as a group" (i.e. simultaneously maximising the benefits of all agents involved) to human-robot cooperative tasks promotes a more seamless and natural interaction. Human-robot coefficiency is first modelled by identifying implicit indicators of human comfort and discomfort as well as calculating the robot energy consumption in performing the desired trajectory. We then present a reinforcement learning approach that uses the human-robot coefficiency score as reward to adapt and learn online the combination of robot interaction parameters that maximises such coefficiency. Results proved that by acting coefficiently the robot could meet the individual preferences of most subjects involved in the experiments, improve the human perceived comfort, and foster trust in the robotic partner.
△ Less
Submitted 12 June, 2023;
originally announced June 2023.
-
The Phase-I Trigger Readout Electronics Upgrade of the ATLAS Liquid Argon Calorimeters
Authors:
G. Aad,
A. V. Akimov,
K. Al Khoury,
M. Aleksa,
T. Andeen,
C. Anelli,
N. Aranzabal,
C. Armijo,
A. Bagulia,
J. Ban,
T. Barillari,
F. Bellachia,
M. Benoit,
F. Bernon,
A. Berthold,
H. Bervas,
D. Besin,
A. Betti,
Y. Bianga,
M. Biaut,
D. Boline,
J. Boudreau,
T. Bouedo,
N. Braam,
M. Cano Bret
, et al. (173 additional authors not shown)
Abstract:
The Phase-I trigger readout electronics upgrade of the ATLAS Liquid Argon calorimeters enhances the physics reach of the experiment during the upcoming operation at increasing Large Hadron Collider luminosities. The new system, installed during the second Large Hadron Collider Long Shutdown, increases the trigger readout granularity by up to a factor of ten as well as its precision and range. Cons…
▽ More
The Phase-I trigger readout electronics upgrade of the ATLAS Liquid Argon calorimeters enhances the physics reach of the experiment during the upcoming operation at increasing Large Hadron Collider luminosities. The new system, installed during the second Large Hadron Collider Long Shutdown, increases the trigger readout granularity by up to a factor of ten as well as its precision and range. Consequently, the background rejection at trigger level is improved through enhanced filtering algorithms utilizing the additional information for topological discrimination of electromagnetic and hadronic shower shapes. This paper presents the final designs of the new electronic elements, their custom electronic devices, the procedures used to validate their proper functioning, and the performance achieved during the commissioning of this system.
△ Less
Submitted 16 May, 2022; v1 submitted 15 February, 2022;
originally announced February 2022.
-
A novel experimental system for the KDK measurement of the $^{40}$K decay scheme relevant for rare event searches
Authors:
M. Stukel,
B. C. Rasco,
N. T. Brewer,
P. C. F. Di Stefano,
K. P. Rykaczewski,
H. Davis,
E. D. Lukosi,
L. Hariasz,
M. Constable,
P. Davis,
K. Dering,
A. Fijałkowska,
Z. Gai,
K. C. Goetz,
R. K. Grzywacz,
J. Kostensalo,
J. Ninkovic,
P. Lechner,
Y. Liu,
M. Mancuso,
C. L. Melcher,
F. Petricca,
C. Rouleau,
P. Squillari,
L. Stand
, et al. (4 additional authors not shown)
Abstract:
Potassium-40 ($^{40}$K) is a long-lived, naturally occurring radioactive isotope. The decay products are prominent backgrounds for many rare event searches, including those involving NaI-based scintillators. $^{40}$K also plays a role in geochronological dating techniques. The branching ratio of the electron capture directly to the ground state of argon-40 has never been measured, which can cause…
▽ More
Potassium-40 ($^{40}$K) is a long-lived, naturally occurring radioactive isotope. The decay products are prominent backgrounds for many rare event searches, including those involving NaI-based scintillators. $^{40}$K also plays a role in geochronological dating techniques. The branching ratio of the electron capture directly to the ground state of argon-40 has never been measured, which can cause difficulty in interpreting certain results or can lead to lack of precision depending on the field and analysis technique. The KDK (Potassium (K) Decay (DK)) collaboration is measuring this decay. A composite method has a silicon drift detector with an enriched, thermally deposited $^{40}$K source inside the Modular Total Absorption Spectrometer. This setup has been characterized in terms of energy calibration, gamma tagging efficiency, live time and false negatives and positives. A complementary, homogeneous, method is also discussed; it employs a KSr$_2$I$_5$:Eu scintillator as source and detector.
△ Less
Submitted 27 July, 2021; v1 submitted 30 December, 2020;
originally announced December 2020.
-
Mechanical Ventilator Milano (MVM): A Novel Mechanical Ventilator Designed for Mass Scale Production in Response to the COVID-19 Pandemic
Authors:
C. Galbiati,
A. Abba,
P. Agnes,
P. Amaudruz,
M. Arba,
F. Ardellier-Desages,
C. Badia,
G. Batignani,
G. Bellani,
G. Bianchi,
D. Bishop,
V. Bocci,
W. Bonivento,
B. Bottino,
M. Bouchard,
S. Brice,
G. Buccino,
S. Bussino,
A. Caminata,
A. Capra,
M. Caravati,
M. Carlini,
L. Carrozzi,
J. M. Cela,
B. Celano
, et al. (123 additional authors not shown)
Abstract:
Presented here is the design of the Mechanical Ventilator Milano (MVM), a novel mechanical ventilator designed for rapid mass production in response to the COVID-19 pandemic to address the urgent shortage of intensive therapy ventilators in many countries, and the growing difficulty in procuring these devices through normal supply chains across borders. This ventilator is an electro-mechanical equ…
▽ More
Presented here is the design of the Mechanical Ventilator Milano (MVM), a novel mechanical ventilator designed for rapid mass production in response to the COVID-19 pandemic to address the urgent shortage of intensive therapy ventilators in many countries, and the growing difficulty in procuring these devices through normal supply chains across borders. This ventilator is an electro-mechanical equivalent of the old and reliable Manley Ventilator, and is able to operate in both pressure-controlled and pressure-supported ventilation modes. MVM is optimized for the COVID-19 emergency, thanks to the collaboration with medical doctors in the front line. MVM is designed for large-scale production in a short amount of time and at a limited cost, as it relays on off-the-shelf components, readily available worldwide. Operation of the MVM requires only a source of compressed oxygen (or compressed medical air) and electrical power. Initial tests of a prototype device with a breathing simulator are also presented. Further tests and developments are underway. At this stage the MVM is not yet a certified medical device but certification is in progress.
△ Less
Submitted 10 April, 2020; v1 submitted 23 March, 2020;
originally announced March 2020.
-
In-beam internal conversion electron spectroscopy with the SPICE detector
Authors:
M. Moukaddam,
J. Smallcombe,
L. J. Evitts,
A. B. Garnsworthy,
C. Andreoiu,
G. C. Ball,
J. Berean-Dutcher,
D. Bishop,
C. Bolton,
R. Caballero-Folch,
M. Constable,
D. S. Cross,
T. E. Drake,
R. Dunlop,
P. E. Garrett,
S. Georges,
G. Hackman,
S. Hallam,
J. Henderson,
R. Henderson,
R. Krücken,
L. Kurchaninov,
A. Kurkjian,
B. Olaizola,
E. O'Sullivan
, et al. (14 additional authors not shown)
Abstract:
The SPectrometer for Internal Conversion Electrons (SPICE) has been commissioned for use in conjunction with the TIGRESS $γ$-ray spectrometer at TRIUMF's ISAC-II facility. SPICE features a permanent rare-earth magnetic lens to collect and direct internal conversion electrons emitted from nuclear reactions to a thick, highly segmented, lithium-drifted silicon detector. This arrangement, combined wi…
▽ More
The SPectrometer for Internal Conversion Electrons (SPICE) has been commissioned for use in conjunction with the TIGRESS $γ$-ray spectrometer at TRIUMF's ISAC-II facility. SPICE features a permanent rare-earth magnetic lens to collect and direct internal conversion electrons emitted from nuclear reactions to a thick, highly segmented, lithium-drifted silicon detector. This arrangement, combined with TIGRESS, enables in-beam $γ$-ray and internal conversion electron spectroscopy to be performed with stable and radioactive ion beams. Technical aspects of the device, capabilities, and initial performance are presented.
△ Less
Submitted 8 August, 2018;
originally announced August 2018.