Skip to main content

Showing 1–6 of 6 results for author: Colonna, D

.
  1. The CMS RPC gas gain monitoring system: an overview and preliminary results

    Authors: L. Benussi, S. Bianco, S. Colafranceschi, D. Colonna, L. Daniello, F. L. Fabbri, M. Giardoni, B. Ortenzi, A. Paolozzi, L. Passamonti, D. Pierluigi, B. Ponzio, C. Pucci, A. Russo, G. Roselli, A. Colaleo, F. Loddo, M. Maggi, A. Ranieri, M. Abbrescia, G. Iaselli, B. Marangelli, S. Natali, S. Nuzzo, G. Pugliese , et al. (18 additional authors not shown)

    Abstract: The status of the CMS RPC Gas Gain Monitoring (GGM) system developed at the Frascati Laboratory of INFN (Istituto Nazionale di Fisica Nucleare) is reported on. The GGM system is a cosmic ray telescope based on small RPC detectors operated with the same gas mixture used by the CMS RPC system. The GGM gain and efficiency are continuously monitored on-line, thus providing a fast and accurate determ… ▽ More

    Submitted 5 December, 2008; originally announced December 2008.

    Comments: 8 pages, 9 figures, uses lnfprepCMS.sty, presented by L. Benussi at RPC07, Mumbai, INDIA 2008

    Report number: Frascati PrePrint LNF-08/29(P)

    Journal ref: Nucl.Instrum.Meth.A602:805-808,2009

  2. arXiv:physics/0701014  [pdf, ps, other

    physics.ins-det

    Gas Analysis and Monitoring Systems for the RPC Detector of CMS at LHC

    Authors: M. Abbrescia, A. Colaleo, R. Guida, G. Iaselli, R. Liuzzi, F. Loddo, M. Maggi, B. Marangelli, S. Natali, S. Nuzzo, G. Pugliese, A. Ranieri, F. Romano, R. Trentadue, L. Benussi, M. Bertani, S. Bianco, M. A. Caponero, D. Colonna, D. Donisi, F. L. Fabbri, F. Felli, M. Giardoni B. Ortenzi, M. Pallotta, A. Paolozzi , et al. (16 additional authors not shown)

    Abstract: The Resistive Plate Chambers (RPC) detector of the CMS experiment at the LHC proton collider (CERN, Switzerland) will employ an online gas analysis and monitoring system of the freon-based gas mixture used. We give an overview of the CMS RPC gas system, describe the project parameters and first results on gas-chromatograph analysis. Finally, we report on preliminary results for a set of monitor… ▽ More

    Submitted 30 December, 2006; originally announced January 2007.

    Comments: 9 pages, 8 figures. Presented by Stefano Bianco (Laboratori Nazionali di Frascati dell'INFN) at the IEEE NSS, San Diego (USA), October 2006

    Report number: Frascati preprint LNF-06/34 (P)

  3. A Novel Approach for an Integrated Straw tube-Microstrip Detector

    Authors: E. Basile, F. Bellucci, L. Benussi, M. Bertani, S. Bianco, M. A. Caponero, D. Colonna, F. Di Falco, F. L. Fabbri, F. Felli, M. Giardoni, A. La Monaca, G. Mensitieri, B. Ortenzi, M. Pallotta, A. Paolozzi, L. Passamonti, D. Pierluigi, C. Pucci, A. Russo, G. Saviano, F. Massa, F. Casali, M. Bettuzzi, D. Bianconi F. Baruffaldi , et al. (1 additional authors not shown)

    Abstract: We report on a novel concept of silicon microstrips and straw tubes detector, where integration is accomplished by a straw module with straws not subjected to mechanical tension in a Rohacell $^{\circledR}$ lattice and carbon fiber reinforced plastic shell. Results on mechanical and test beam performances are reported on as well.

    Submitted 28 December, 2005; originally announced December 2005.

    Comments: Accepted by Transactions on Nuclear Science (2005). 11 pages, 9 figures, uses lnfprep.sty

    Report number: LNF-05/32(P)

    Journal ref: IEEE Trans.Nucl.Sci. 53 (2006) 1375-1379

  4. Two- and Three-Dimensional Reconstruction and Analysis of the Straw Tubes Tomography in the Btev Experiment

    Authors: E. Basile, F. Bellucci, L. Benussi, M. Bertani, S. Bianco, M. A. Caponero, D. Colonna, F. Di Falco, F. L. Fabbri, F. Felli, M. Giardoni, A. La Monaca, F. Massa, G. Mensitieri, B. Ortenzi, M. Pallotta, A. Paolozzi, L. Passamonti, D. Pierluigi, C. Pucci, A. Russo, G. Saviano F. Casali, M. Bettuzzi, D. Bianconi

    Abstract: A check of the eccentricity of the aluminised kapton straw tubes used in the BTeV experiment is accomplished using X-ray tomography of the section of tubes modules. 2 and 3-dimensional images of the single tubes and of the modules are reconstructed and analysed. Preliminary results show that a precision better than 40 $μ$m can be reached on the measurement of the straw radii.

    Submitted 28 December, 2005; originally announced December 2005.

    Comments: Presented by F.Massa at ICATPP05, Villa Olmo (Como) Italy, November 2005. 4 pages, 8 figures, uses lnfprep.sty

    Report number: LNF-05/31(P)

  5. Micrometric Position Monitoring Using Fiber Bragg Grating Sensors in Silicon Detectors

    Authors: E. Basile, F. Bellucci, L. Benussi, M. Bertani, S. Bianco, M. A. Caponero, D. Colonna, F. Di Falco, F. L. Fabbri, F. Felli, M. Giardoni, A. La Monaca, F. Massa, G. Mensitieri, B. Ortenzi, M. Pallotta, A. Paolozzi, L. Passamonti, D. Pierluigi, C. Pucci, A. Russo, G. Saviano

    Abstract: We show R&D results including long term stability, resolution, radiation hardness and characterization of Fiber Grating sensors used to monitor structure deformation, repositioning and surveying of silicon detector in High Energy Physics.

    Submitted 28 December, 2005; originally announced December 2005.

    Comments: Presented by S.Bianco at ICATPP05, Villa Olmo (Como) Italy, November 2005. 5 pages, 6 figures, uses lnfprep.sty

    Report number: LNF-05/30(P)

  6. arXiv:physics/0412100  [pdf, ps, other

    physics.ins-det

    An Uncoventional Approach for a Straw Tube-Microstrip Detector

    Authors: E. Basile, F. Bellucci, L. Benussi, M. Bertani, S. Bianco, M. A. Caponero, D. Colonna, F. Di Falco, F. L. Fabbri, F. Felli, M. Giardoni, A. La Monaca, G. Mensitieri, B. Ortenzi, M. Pallotta, A. Paolozzi, L. Passamonti, D. Pierluigi, C. Pucci, A. Russo, G. Saviano, S. Tomassini

    Abstract: We report on a novel concept of silicon microstrips and straw tubes detector, where integration is accomplished by a straw module with straws not subjected to mechanical tension in a Rohacell lattice and carbon fiber reinforced plastic shell. Results on mechanical and test beam performances are reported on as well.

    Submitted 16 December, 2004; originally announced December 2004.

    Comments: 8 pages, 7 figures uses an lnfprep.sty

    Report number: LNF-04/25 (P)