-
Imaging nanomechanical vibrations and manipulating parametric mode coupling via scanning microwave microscopy
Authors:
Hao Xu,
Srisaran Venkatachalam,
Toky-Harrison Rabenimanana,
Christophe Boyaval,
Sophie Eliet,
Flavie Braud,
Eddy Collin,
Didier Theron,
Xin Zhou
Abstract:
In this study, we present a novel platform based on scanning microwave microscopy for manipulating and detecting tiny vibrations of nanoelectromechanical resonators using a single metallic tip. The tip is placed on the top of a grounded silicon nitride membrane, acting as a movable top gate of the coupled resonator. We demonstrate its ability to map mechanical modes and investigate mechanical damp…
▽ More
In this study, we present a novel platform based on scanning microwave microscopy for manipulating and detecting tiny vibrations of nanoelectromechanical resonators using a single metallic tip. The tip is placed on the top of a grounded silicon nitride membrane, acting as a movable top gate of the coupled resonator. We demonstrate its ability to map mechanical modes and investigate mechanical dam** effects in a capacitive coupling scheme, based on its spatial resolution. We also manipulate the energy transfer coherently between the mode of the scanning tip and the underlying silicon nitride membrane, via parametric coupling. Typical features of optomechanics, such as anti-dam** and electromechanically induced transparency, have been observed. Since the microwave optomechanical technology is fully compatible with quantum electronics and very low temperature conditions, it should provide a powerful tool for studying phonon tunnelling between two spatially separated vibrating elements, which could potentially be applied to quantum sensing.
△ Less
Submitted 28 June, 2024;
originally announced July 2024.
-
Aluminum nuclear demagnetization refrigerator for powerful continuous cooling
Authors:
Matthias Raba,
Sébastien Triqueneaux,
James Butterworth,
David Schmoranzer,
Emilio Barria,
Jérôme Debray,
Guillaume Donnier-Valentin,
Thibaut Gandit,
Anne Gerardin,
Johannes Goupy,
Olivier Tissot,
Eddy Collin,
Andrew Fefferman
Abstract:
Many laboratories routinely cool samples to 10 mK, but relatively few can cool condensed matter below 1 mK. Easy access to the microkelvin range would propel fields such as quantum sensors and quantum materials. Such temperatures are achieved with adiabatic nuclear demagnetization. Existing nuclear demagnetization refrigerators (NDR) are "single-shot", and the recycling time is incompatible with p…
▽ More
Many laboratories routinely cool samples to 10 mK, but relatively few can cool condensed matter below 1 mK. Easy access to the microkelvin range would propel fields such as quantum sensors and quantum materials. Such temperatures are achieved with adiabatic nuclear demagnetization. Existing nuclear demagnetization refrigerators (NDR) are "single-shot", and the recycling time is incompatible with proposed sub-mK experiments. Furthermore, a high cooling power is required to overcome the excess heat load of order nW on NDR pre-cooled by cryogen-free dilution refrigerators. We report the performance of an aluminum NDR designed for powerful cooling when part of a dual stage continuous NDR (CNDR). Its thermal resistance is minimized to maximize the cycling rate of the CNDR and consequently its cooling power. At the same time, its susceptibility to eddy current heating is minimized. A CNDR based on two of the aluminum NDR presented here would have a cooling power of approximately 40 nW at 560 $μ$K.
△ Less
Submitted 30 April, 2024;
originally announced April 2024.
-
Self-sustained optomechanical state destruction triggered by the Kerr nonlinearity
Authors:
A. Delattre,
I. Golokolenov,
R. Pedurand,
X. Zhou,
A. Fefferman,
E. Collin
Abstract:
Cavity optomechanics implements a unique platform where moving objects can be probed by quantum fields, either laser light or microwave signals. With a pump tone driving at a frequency above the cavity resonance, self-sustained oscillations can be triggered at large injected powers. These limit cycle dynamics are particularly rich, presenting hysteretic behaviours, broad comb signals and especiall…
▽ More
Cavity optomechanics implements a unique platform where moving objects can be probed by quantum fields, either laser light or microwave signals. With a pump tone driving at a frequency above the cavity resonance, self-sustained oscillations can be triggered at large injected powers. These limit cycle dynamics are particularly rich, presenting hysteretic behaviours, broad comb signals and especially large motion amplitudes. All of these features can be exploited for both fundamental quantum research and engineering. Here we present low temperature microwave experiments performed on a high-Q cavity resonance capacitively coupled to the flexure of a beam resonator. We study the limit cycle dynamics phase space as a function of pump parameters (detuning, power). Unexpectedly, we find that in a region of this phase space the microwave resonance is irremediably destroyed: only a dramatic power-reset can restore the dynamics to its original state. The phenomenon can be understood as an optical instability linked to the Kerr nonlinearity of the cavity. A theory supporting this claim is presented, reproducing almost quantitatively the measurement. This remarkable feature might be further optimized and represents a new resource for quantum microwave circuits.
△ Less
Submitted 6 March, 2024;
originally announced March 2024.
-
Progress toward detection of individual TLS in nanomechanical resonators
Authors:
Richard Pedurand,
Ilya Golokolenov,
Mika Sillanpää,
Laure Mercier de Lépinay,
Eddy Collin,
Andrew Fefferman
Abstract:
The low temperature properties of amorphous solids are usually explained in terms of atomic-scale tunneling two level systems (TLS). For almost 20 years, individual TLS have been probed in insulating layers of superconducting quantum circuits. Detecting individual TLS in mechanical systems has been proposed but not definitively demonstrated. We describe an optomechanical system that is appropriate…
▽ More
The low temperature properties of amorphous solids are usually explained in terms of atomic-scale tunneling two level systems (TLS). For almost 20 years, individual TLS have been probed in insulating layers of superconducting quantum circuits. Detecting individual TLS in mechanical systems has been proposed but not definitively demonstrated. We describe an optomechanical system that is appropriate for this goal and describe our progress toward achieving it. In particular, we show that the expected coupling between the mechanical mode and a resonant TLS is strong enough for high visibility of a TLS given the linewidth of the mechanical mode. Furthermore, the electronic noise level of our measurement system is low enough and the anomalous force noise observed in other nanomechanical devices is absent.
△ Less
Submitted 14 January, 2024;
originally announced January 2024.
-
On the link between mechanics and thermal properties: mechanothermics
Authors:
Eddy Collin,
Ilya Golokolenov,
Olivier Maillet,
Laurent Saminadayar,
Olivier Bourgeois
Abstract:
We report on the theoretical derivation of macroscopic thermal properties (specific heat, thermal conductivity) of an electrically insulating rod connected to two reservoirs, from the linear superposition of its mechanical mode Brownian motions. The calculation is performed for a weak thermal gradient, in the classical limit (high temperature). The development is kept basic as far as geometry and…
▽ More
We report on the theoretical derivation of macroscopic thermal properties (specific heat, thermal conductivity) of an electrically insulating rod connected to two reservoirs, from the linear superposition of its mechanical mode Brownian motions. The calculation is performed for a weak thermal gradient, in the classical limit (high temperature). The development is kept basic as far as geometry and experimental conditions are concerned, enabling an almost fully analytic treatment. In the modeling, each of the modes is subject to a specific Langevin force, which enables to produce the required temperature profile along the rod. The theory is predictive: the temperature gradient (and therefore energy transport) is linked to motion amplitude cross-correlations between nearby mechanical modes. This arises because energy transport is actually mediated by mixing between the modal waves, and not by the modes themselves. This result can be tested on experiments, and shall extend the concepts underlying equipartition and fluctuation-dissipation theorems. The theory links intimately the macroscopic size of the clam** region where the mixing occurs to the microscopic lengthscale of the problem at hand: the phonon mean-free-path. This clam** region, which is key, has received recently a renewed attention in the field of nanomechanics with topical works on "phonon shields" and "soft clam**". We believe that our work should impact the domain of thermal transport in nanostructures, with future developments of the theory toward the quantum regime.
△ Less
Submitted 11 April, 2023; v1 submitted 28 November, 2022;
originally announced November 2022.
-
Nano-beam clam** revisited
Authors:
Ilya Golokolenov,
Sumit Kumar,
Baptiste Alperin,
Bruno Fernandez,
Andrew Fefferman,
Eddy Collin
Abstract:
Within recent years, the field of nano-mechanics has diversified in a variety of applications, ranging from quantum information processing to biological molecules recognition. Among the diversity of devices produced these days, the simplest (but versatile) element remains the doubly-clamped beam: it can store very large tensile stresses (producing high resonance frequencies $f_0$ and quality facto…
▽ More
Within recent years, the field of nano-mechanics has diversified in a variety of applications, ranging from quantum information processing to biological molecules recognition. Among the diversity of devices produced these days, the simplest (but versatile) element remains the doubly-clamped beam: it can store very large tensile stresses (producing high resonance frequencies $f_0$ and quality factors $Q$), is interfaceable with electric setups (by means of conductive layers), and can be produced easily in clean rooms (with scalable designs including multiplexing). Besides, its mechanical properties are the simplest to describe. Resonance frequencies and $Q$s are being modeled, with as specific achievement the ultra-high quality resonances based on ``soft clam**'' and ``phonon shields''. Here, we demonstrate that the fabrication undercut of the clam** regions of basic nano-beams produces a ``natural soft clam**'', given for free. We present the analytic theory that enables to fit experimental data, which can be used for $\{ Q , f_0 \}$ design: beyond Finite Element Modeling validation, the presented expressions provide a profound understanding of the phenomenon, with both a Q enhancement and a downwards frequency shift.
△ Less
Submitted 31 March, 2023; v1 submitted 3 November, 2022;
originally announced November 2022.
-
Thermodynamics of a Single Mesoscopic Phononic Mode
Authors:
Ilya Golokolenov,
Arpit Ranadive,
Luca Planat,
Martina Esposito,
Nicolas Roch,
Xin Zhou,
Andrew Fefferman,
Eddy Collin
Abstract:
In recent decades, the laws of thermodynamics have been pushed down to smaller and smaller scales, within the field of stochastic thermodynamics and state-of-art experiments performed on mesoscopic systems. These measurements concern electrons, photons, and mesoscopic mechanical objects. Here we report on the measurements of thermal fluctuations of a single mechanical mode in-equilibrium with a he…
▽ More
In recent decades, the laws of thermodynamics have been pushed down to smaller and smaller scales, within the field of stochastic thermodynamics and state-of-art experiments performed on mesoscopic systems. These measurements concern electrons, photons, and mesoscopic mechanical objects. Here we report on the measurements of thermal fluctuations of a single mechanical mode in-equilibrium with a heat reservoir. The device under study is a nanomechanical beam with a first flexure resonating at 3.8MHz, cooled down to temperatures in the range from 100mK to 400mK. The technique is constructed around a microwave opto-mechanical setup using a cryogenic High Electron Mobility Transistor, and is based on two parametric amplifications implemented in series: an in-built opto-mechanical 'blue-detuned' pum** plus a Traveling Wave Parametric Amplifier stage. We demonstrate our ability to resolve energy fluctuations of the mechanical mode in real-time up to the fastest relevant speed given by the mechanical relaxation rate. The energy probability distribution is then exponential, matching the expected Boltzmann distribution. The variance of fluctuations is found to be $(k_B T)^2$ with no free parameters. Our microwave detection floor is about 3 Standard Quantum Limit at 6GHz; the resolution of our fastest acquisition tracks reached about 100 phonons, and is related to the rather poor opto-mechanical coupling of the device ($g_0/2π\approx 0.5~$Hz). This result is deeply in the classical regime, but shall be extended to the quantum case in the future with systems presenting a much larger $g_0$ (up to $2π\times 250~$Hz), potentially reaching the resolution of a single mechanical quantum. We believe that it will open a new experimental field: phonon-based quantum stochastic thermodynamics, with fundamental implications for quantum heat transport and macroscopic mechanical quantum coherence.
△ Less
Submitted 25 January, 2023; v1 submitted 17 August, 2022;
originally announced August 2022.
-
Specific Heat of Thin Phonon Cavities at Low Temperature: Very High Values Revealed by ZeptoJoule Calorimetry
Authors:
Adib Tavakoli,
Kunal J. Lulla,
Tuomas Puurtinen,
Ilari Maasilta,
Eddy Collin,
Laurent Saminadayar,
Olivier Bourgeois
Abstract:
Specific heat of phonon cavities is investigated in order to analyse the effect of phonon confinement on thermodynamic properties. The specific heat of free standing very thin SiN membranes in the low dimensional limit is measured down to very low temperatures (from 6~K to 50~mK). In the whole temperature range, we measured an excess of specific heat orders of magnitude bigger than the typical val…
▽ More
Specific heat of phonon cavities is investigated in order to analyse the effect of phonon confinement on thermodynamic properties. The specific heat of free standing very thin SiN membranes in the low dimensional limit is measured down to very low temperatures (from 6~K to 50~mK). In the whole temperature range, we measured an excess of specific heat orders of magnitude bigger than the typical value observed in amorphous solids. Below 1~K, a cross-over in $c_p$ to a lower power law is seen, and the value of specific heat of thinner membranes becomes larger than that of thicker ones demonstrating a significant contribution coming from the surface. We show that this high value of the specific heat cannot be explained by the sole contribution of 2D phonon modes (Lamb waves). The excess specific heat, being thickness dependent, could come from tunneling two level systems (TLS) that form in low density regions of amorphous solids located on the surfaces. We also show that the specific heat is strongly tuned by the internal stress of the membrane by orders of magnitude, giving unprecedentedly high values, making low stress SiN very efficient for energy storage at very low temperature.
△ Less
Submitted 15 June, 2022;
originally announced June 2022.
-
Mesoscopic Quantum Thermo-mechanics: a new frontier of experimental physics
Authors:
E. Collin
Abstract:
Within the last decade, experimentalists have demonstrated their impressive ability to control mechanical modes within mesoscopic objects down to the quantum level: it is now possible to create mechanical Fock states, to entangle mechanical modes from distinct objects, store quantum information or transfer it from one quantum bit to another, among the many possibilities found in today's literature…
▽ More
Within the last decade, experimentalists have demonstrated their impressive ability to control mechanical modes within mesoscopic objects down to the quantum level: it is now possible to create mechanical Fock states, to entangle mechanical modes from distinct objects, store quantum information or transfer it from one quantum bit to another, among the many possibilities found in today's literature. Indeed mechanics is quantum, very much like spins or electromagnetic degrees of freedom. And all of this is in particular referred to as a new engineering resource for quantum technologies. But there is also much more beyond this utilitarian aspect: invoking the original discussions of Braginsky and Caves where a quantum oscillator is thought of as a quantum detector for a classical field, namely a gravitational wave, it is also a unique sensing capability for quantum fields. The subject of study is then the baths to which the mechanical mode is coupled to, let them be known or unknown in nature. This Letter is about this new potentiality, that addresses stochastic thermodynamics, potentially down to its quantum version, the search for a fundamental underlying (random) field postulated in recent theories that can be affiliated to the class of the Wave-function Collapse models, and more generally open questions of Condensed Matter like the actual nature of the elusive (and ubiquitous) Two-Level Systems present within all mechanical objects. But such research turns out to be much more demanding than the usage of a few quantum mechanical modes: all the known baths have to be identified, experiments have to be conducted in-equilibrium, and the word "mechanics" needs to be justified by a real ability to move substantially the centre-of-mass when a proper drive tone is applied to the system.
△ Less
Submitted 20 April, 2022;
originally announced April 2022.
-
Capacitively coupled distinct mechanical resonators for room temperature phonon-cavity electromechanics
Authors:
Alok Pokharel,
Hao Xu,
Srisaran Venkatachalam,
Eddy Collin,
Xin Zhou
Abstract:
Coupled electromechanical resonators that can be independently driven/detected and easily integrated with external circuits are essential for exploring mechanical modes based signal processing. Here, we present a room temperature phonon-cavity electromechanical system, consisting of two distinct resonators: a silicon nitride electromechanical drum capacitively coupled to an aluminum one. We demons…
▽ More
Coupled electromechanical resonators that can be independently driven/detected and easily integrated with external circuits are essential for exploring mechanical modes based signal processing. Here, we present a room temperature phonon-cavity electromechanical system, consisting of two distinct resonators: a silicon nitride electromechanical drum capacitively coupled to an aluminum one. We demonstrate electromechanically induced transparency and amplification in a two-tone driving scheme and observe the phonon-cavity force affecting the mechanical dam** rates of both movable objects. We also develop an analytical model based on linearly coupled motion equations, which captures the optomechanical features in the classical limit and enables to fit quantitatively our measurements. Our results open up new possibilities in the study of phonon-cavity based signal processing in the classical and potentially in the future in the quantum regimes.
△ Less
Submitted 10 April, 2022;
originally announced April 2022.
-
Superconducting aluminum heat switch with 3 n$Ω$ equivalent resistance
Authors:
James Butterworth,
Sébastien Triqueneaux,
Šimon Midlik,
Ilya Golokolenov,
Anne Gerardin,
Thibaut Gandit,
Guillaume Donnier-Valentin,
Johannes Goupy,
M. Keith Phuthi,
David Schmoranzer,
Eddy Collin,
Andrew Fefferman
Abstract:
Superconducting heat switches with extremely low normal state resistances are needed for constructing continuous nuclear demagnetization refrigerators with high cooling power. Aluminum is a suitable superconductor for the heat switch because of its high Debye temperature and its commercial availability in high purity. We have constructed a high quality Al heat switch whose design is significantly…
▽ More
Superconducting heat switches with extremely low normal state resistances are needed for constructing continuous nuclear demagnetization refrigerators with high cooling power. Aluminum is a suitable superconductor for the heat switch because of its high Debye temperature and its commercial availability in high purity. We have constructed a high quality Al heat switch whose design is significantly different than that of previous heat switches. In order to join the Al to Cu with low contact resistance, we plasma etched the Al to remove its oxide layer then immediately deposited Au without breaking the vacuum of the e-beam evaporator. In the normal state of the heat switch, we measured a thermal conductance of $8 T$ W/K$^2$ which is equivalent to an electrical resistance of 3 n$Ω$ according to the Wiedemann-Franz law. In the superconducting state we measured a thermal conductance that is $2\times10^6$ times lower than that of the normal state at 50 mK.
△ Less
Submitted 23 April, 2022; v1 submitted 23 November, 2021;
originally announced November 2021.
-
Fully suspended nano-beams for quantum fluids
Authors:
Ilya Golokolenov,
Baptiste Alperin,
Bruno Fernandez,
Andrew Fefferman,
Eddy Collin
Abstract:
Non-invasive probes are keystones of fundamental research. Their size, and maneuverability (in terms of e.g. speed, dissipated power) define their applicability range for a specific use. As such, solid state physics possesses e.g. Atomic Force Microscopy (AFM), Scanning Tunneling Microscopy (STM), or Scanning SQUID Microscopy. In comparison, quantum fluids (superfluid $^3$He, $^4$He) are still lac…
▽ More
Non-invasive probes are keystones of fundamental research. Their size, and maneuverability (in terms of e.g. speed, dissipated power) define their applicability range for a specific use. As such, solid state physics possesses e.g. Atomic Force Microscopy (AFM), Scanning Tunneling Microscopy (STM), or Scanning SQUID Microscopy. In comparison, quantum fluids (superfluid $^3$He, $^4$He) are still lacking probes able to sense them (in a fully controllable manner) down to their smallest relevant lengthscales, namely the coherence length $ξ_0$. In this work we report on the fabrication and cryogenic characterization of fully suspended (hanging over an open window, with no substrate underneath) Si$_3$N$_4$ nano-beams, of width down to 50 nm and quality factor up to $10^5$. As a benchmark experiment we used them to investigate the Knudsen boundary layer of a rarefied gas: $^4$He at very low pressures. The absence of the rarefaction effect due to the nearby chip surface discussed in Gazizulin et al. [1] is attested, while we report on the effect of the probe size itself.
△ Less
Submitted 22 April, 2022; v1 submitted 9 November, 2021;
originally announced November 2021.
-
Microwave optomechanical measurement of non-metallized SiN strings at mK temperatures
Authors:
Sumit Kumar,
Yannick Klaß,
Baptiste Alperin,
Srisaran Venkatachalam,
Xin Zhou,
Eva Weig,
Eddy Collin,
Andrew Fefferman
Abstract:
The mechanical properties of amorphous materials (glasses) at low temperatures are dominated by effects of low energy excitations that are thought to be atomic-scale tunneling two level systems (TTLS). In nanometer-scale glass samples, the temperature dependence of the sound speed and dissipation is modified relative to that of bulk glass samples. In addition to this size effect, the usual presenc…
▽ More
The mechanical properties of amorphous materials (glasses) at low temperatures are dominated by effects of low energy excitations that are thought to be atomic-scale tunneling two level systems (TTLS). In nanometer-scale glass samples, the temperature dependence of the sound speed and dissipation is modified relative to that of bulk glass samples. In addition to this size effect, the usual presence of a polycrystalline metal in nanomechanical resonators leads to a further departure from the well-studied behavior of insulating bulk glass. We report a dual chip optomechanical measurement technique used to characterize non-metallized amorphous SiN strings at low temperatures. A harp consisting of SiN strings of width 350 nm and lengths 40 to 80 $μ$m is coupled to an Al superconducting microwave cavity on a separate chip. The strings are driven dielectrically and their motion is detected via its modulation of the microwave resonance frequency.
△ Less
Submitted 1 October, 2021;
originally announced October 2021.
-
Develo** compact tuning fork thermometers for sub-mK temperatures and high magnetic fields
Authors:
Andrew J. Woods,
Alexander. M. Donald,
Rasul Gazizulin,
Eddy Collin,
Lucia Steinke
Abstract:
There is a growing demand for experiments on calorimetric and thermal transport measurements at ultra-low temperatures below 1 mK and high magnetic fields up to 16 T. Particularly, milligram-sized solid samples are of great interest. We present the development of scalable thermometers based on quartz tuning fork resonators immersed in liquid 3He and adapt hydrodynamic models to provide an improved…
▽ More
There is a growing demand for experiments on calorimetric and thermal transport measurements at ultra-low temperatures below 1 mK and high magnetic fields up to 16 T. Particularly, milligram-sized solid samples are of great interest. We present the development of scalable thermometers based on quartz tuning fork resonators immersed in liquid 3He and adapt hydrodynamic models to provide an improved description of temperature dependence in the high viscosity regime between 1 and 10 mK. We demonstrate successful thermometer operation and discuss the feasibility of fast and compact thermal probes suitable for small samples.
△ Less
Submitted 13 October, 2022; v1 submitted 6 July, 2021;
originally announced July 2021.
-
A macroscopic object passively cooled into its quantum ground state of motion: beyond single-mode cooling
Authors:
D. Cattiaux,
I. Golokolenov,
S. Kumar,
M. Sillanpää,
L. Mercier de Lépinay,
R. R. Gazizulin,
X. Zhou,
A. D. Armour,
O. Bourgeois,
A. Fefferman,
E. Collin
Abstract:
The building blocks of Nature, namely atoms and elementary particles, are described by quantum mechanics. This fundamental theory is the ground on which physicists have built their major mathematical models [1]. Today, the unique features of quantum objects have led to the advent of promising quantum technologies [2, 3]. However, the macroscopic world is manifestly classical, and the nature of the…
▽ More
The building blocks of Nature, namely atoms and elementary particles, are described by quantum mechanics. This fundamental theory is the ground on which physicists have built their major mathematical models [1]. Today, the unique features of quantum objects have led to the advent of promising quantum technologies [2, 3]. However, the macroscopic world is manifestly classical, and the nature of the quantum-to-classical crossover remains one of the most challenging open question of Science to date. In this respect, moving objects play a specific role [4, 5]. Pioneering experiments over the last few years have begun exploring quantum behaviour of micron-sized mechanical systems,either by passively cooling single GHz modes, or by adapting laser cooling techniques developed in atomic physics to cool specific modes far below the temperature of their surroundings [6-11]. Here instead we describe a very different approach, passive cooling of a micromechanical system down to 500 microK, reducing the average number of quanta in the fundamental vibrational mode at 15 MHz to just 0.3 (with even lower values expected for higher harmonics); the challenge being to be still able to detect the motion without disturbing the system noticeably. With such an approach higher harmonics and the surrounding environment are also cooled, leading to potentially much longer mechanical coherence times, and enabling experiments questioning mechanical wave-function collapse [12], potentially from the gravitational background [13, 14], and quantum thermodynamics [15]. Beyond the average behaviour, here we also report on the fluctuations of the fundamental vibrational mode of the device in-equilibrium with the cryostat. These reveal a surprisingly complex interplay with the local environment and allow characteristics of two distinct thermodynamic baths to be probed.
△ Less
Submitted 26 October, 2021; v1 submitted 19 April, 2021;
originally announced April 2021.
-
Microwave Optomechanically Induced Transparency and Absorption Between 250 and 450 mK
Authors:
Sumit Kumar,
Dylan Cattiaux,
Eddy Collin,
Andrew Fefferman,
Xin Zhou
Abstract:
High-quality microwave amplifiers and notch-filters can be made from microwave optomechanical systems in which a mechanical resonator is coupled to a microwave cavity by radiation pressure. These amplifiers and filters rely on optomechanically induced transparency (OMIT) and absorption (OMIA), respectively. Such devices can amplify microwave signals with large, controllable gain, high dynamic rang…
▽ More
High-quality microwave amplifiers and notch-filters can be made from microwave optomechanical systems in which a mechanical resonator is coupled to a microwave cavity by radiation pressure. These amplifiers and filters rely on optomechanically induced transparency (OMIT) and absorption (OMIA), respectively. Such devices can amplify microwave signals with large, controllable gain, high dynamic range and very low noise. Furthermore, extremely narrowband filters can be constructed with this technique. We briefly review previous measurements of microwave OMIT and OMIA before reporting our own measurements of these phenomena, which cover a larger parameter space than has been explored in previous works. In particular, we vary probe frequency, pump frequency, pum** scheme (red or blue), probe power, pump power and temperature. We find excellent agreement between our measurements and the predictions of input/output theory, thereby guiding further development of microwave devices based on nanomechanics.
△ Less
Submitted 30 January, 2022; v1 submitted 19 April, 2021;
originally announced April 2021.
-
High-Q silicon nitride drum resonators strongly coupled to gates
Authors:
Xin Zhou,
Srisaran Venkatachalam,
Ronghua Zhou,
Hao Xu,
Alok Pokharel,
Andrew Fefferman,
Mohammed Zaknoune,
Eddy Collin
Abstract:
Silicon nitride (SiN) mechanical resonators with high quality mechanical properties are attractive for fundamental research and applications. However, it is challenging to maintain these mechanical properties while achieving strong coupling to an electrical circuit for efficient on-chip integration. Here, we present a SiN drum resonator covered with an aluminum thin film, enabling large capacitive…
▽ More
Silicon nitride (SiN) mechanical resonators with high quality mechanical properties are attractive for fundamental research and applications. However, it is challenging to maintain these mechanical properties while achieving strong coupling to an electrical circuit for efficient on-chip integration. Here, we present a SiN drum resonator covered with an aluminum thin film, enabling large capacitive coupling to a suspended top-gate. Implementing the full electrical measurement scheme, we demonstrate a high quality factor ~ 1E4 (comparable to that of bare drums at room temperature) and present our ability to detect ? 10 mechanical modes at low temperature. The drum resonator is also coupled to a microwave cavity, so that we can perform optomechanical sideband pum** with a fairly good coupling strength G and demonstrate mechanical parametric amplification. This SiN drum resonator design provides efficient electrical integration and exhibits promising features for exploring mode coupling and signal processing.
△ Less
Submitted 16 June, 2021; v1 submitted 14 April, 2021;
originally announced April 2021.
-
Microwave single-tone optomechanics in the classical regime
Authors:
Ilya Golokolenov,
Dylan Cattiaux,
Sumit Kumar,
Mika Sillanpää,
Laure Mercier de Lépinay,
Andrew Fefferman,
Eddy Collin
Abstract:
We report on the quantitative experimental illustration of elementary optomechanics within the classical regime. All measurements are performed in a commercial dilution refrigerator on a mesoscopic drumhead aluminium resonator strongly coupled to a microwave cavity, using only strict single-tone schemes. Sideband asymmetry is reported using in-cavity microwave pum**, along with noise squashing a…
▽ More
We report on the quantitative experimental illustration of elementary optomechanics within the classical regime. All measurements are performed in a commercial dilution refrigerator on a mesoscopic drumhead aluminium resonator strongly coupled to a microwave cavity, using only strict single-tone schemes. Sideband asymmetry is reported using in-cavity microwave pum**, along with noise squashing and back-action effects. Results presented in this paper are analysed within the simple classical electric circuit theory, emphasizing the analogous nature of classical features with respect to their usual quantum description. The agreement with theory is obtained with no fitting parameters. Besides, based on those results a simple method is proposed for the accurate measurement of the ratio between microwave internal losses and external coupling.
△ Less
Submitted 7 May, 2021; v1 submitted 27 November, 2020;
originally announced November 2020.
-
Nanomechanical dam** via electron-assisted relaxation of two-level systems
Authors:
Olivier Maillet,
Dylan Cattiaux,
Xin Zhou,
Rasul R. Gazizulin,
Olivier Bourgeois,
Andrew D. Fefferman,
Eddy Collin
Abstract:
We report on measurements of dissipation and frequency noise at millikelvin temperatures of nanomechanical devices covered with aluminum. A clear excess dam** is observed after switching the metallic layer from superconducting to the normal state with a magnetic field. Beyond the standard model of internal tunneling systems coupled to the phonon bath, here we consider the relaxation to the condu…
▽ More
We report on measurements of dissipation and frequency noise at millikelvin temperatures of nanomechanical devices covered with aluminum. A clear excess dam** is observed after switching the metallic layer from superconducting to the normal state with a magnetic field. Beyond the standard model of internal tunneling systems coupled to the phonon bath, here we consider the relaxation to the conduction electrons together with the nature of the mechanical dispersion laws for stressed/unstressed devices. With these key ingredients, a model describing the relaxation of two-level systems inside the structure due to interactions with electrons and phonons with well separated timescales captures the data. In addition, we measure an excess 1/f-type frequency noise in the normal state, which further emphasizes the impact of conduction electrons.
△ Less
Submitted 22 February, 2023; v1 submitted 8 September, 2020;
originally announced September 2020.
-
Very low resistance Al/Cu joints for use at cryogenic temperatures
Authors:
Sébastien Triqueneaux,
James Butterworth,
Johannes Goupy,
Clément Ribas,
David Schmoranzer,
Eddy Collin,
Andrew Fefferman
Abstract:
We present two different techniques for achieving low resistance ($<$20 n$\rm Ω$) contacts between copper and aluminium at cryogenic temperatures. The best method is based on gold plating of the surfaces in an e-beam evaporator immediately after Ar plasma etching in the same apparatus, yielding resistances as low as 3 n$\rm Ω$ that are stable over time. The second approach involves inserting indiu…
▽ More
We present two different techniques for achieving low resistance ($<$20 n$\rm Ω$) contacts between copper and aluminium at cryogenic temperatures. The best method is based on gold plating of the surfaces in an e-beam evaporator immediately after Ar plasma etching in the same apparatus, yielding resistances as low as 3 n$\rm Ω$ that are stable over time. The second approach involves inserting indium in the Al/Cu joint. For both methods, we believe key elements are surface polishing, total removal of the aluminum oxide surface layer, and temporary application of large (typ. 11 kN) compression forces. We believe the values for gold plated contacts are the lowest ever reported for a Cu/Al joint of a few $\rm cm^{2}$. This technology could simplify the construction of thermal links for advanced cryogenics applications, in particular that of extremely low resistance heat switches for nuclear demagnetization refrigerators.
△ Less
Submitted 31 March, 2021; v1 submitted 4 September, 2020;
originally announced September 2020.
-
Electric circuit model of microwave optomechanics
Authors:
Xin Zhou,
Dylan Cattiaux,
Didier Theron,
Eddy Collin
Abstract:
We report on the generic classical electric circuit modeling that describes standard single-tone microwave optomechanics. Based on a parallel RLC circuit in which a mechanical oscillator acts as a movable capacitor, derivations of analytical expressions are presented, including key features such as the back-action force, the input-output expressions, and the spectral densities associated, all in t…
▽ More
We report on the generic classical electric circuit modeling that describes standard single-tone microwave optomechanics. Based on a parallel RLC circuit in which a mechanical oscillator acts as a movable capacitor, derivations of analytical expressions are presented, including key features such as the back-action force, the input-output expressions, and the spectral densities associated, all in the classical regime. These expressions coincide with the standard quantum treatment performed in optomechanics when the occupation number of both cavity and mechanical oscillator are large. Besides, the derived analytics transposes optical elements and properties into electronics terms, which is mandatory for quantitative measurement and design purposes. Finally, the direct comparison between the standard quantum treatment and the classical model addresses the bounds between quantum and classical regimes, highlighting the features which are truly quantum, and those which are not.
△ Less
Submitted 27 October, 2020; v1 submitted 28 July, 2020;
originally announced July 2020.
-
Beyond linear coupling in microwave optomechanics
Authors:
D. Cattiaux,
X. Zhou,
S. Kumar,
I. Golokolenov,
R. R. Gazizulin,
A. Luck,
L. Mercier de Lépinay,
M. Sillanpää,
A. D. Armour,
A. Fefferman,
E. Collin
Abstract:
We explore the nonlinear dynamics of a cavity optomechanical system. Our realization consisting of a drumhead nano-electro-mechanical resonator (NEMS) coupled to a microwave cavity, allows for a nearly ideal platform to study the nonlinearities arising purely due to radiation-pressure physics. Experiments are performed under a strong microwave Stokes pum** which triggers mechanical self-sustaine…
▽ More
We explore the nonlinear dynamics of a cavity optomechanical system. Our realization consisting of a drumhead nano-electro-mechanical resonator (NEMS) coupled to a microwave cavity, allows for a nearly ideal platform to study the nonlinearities arising purely due to radiation-pressure physics. Experiments are performed under a strong microwave Stokes pum** which triggers mechanical self-sustained oscillations. We analyze the results in the framework of an extended nonlinear optomechanical theory, and demonstrate that quadratic and cubic coupling terms in the opto-mechanical Hamiltonian have to be considered. Quantitative agreement with the measurements is obtained considering only genuine geometrical nonlinearities: no thermo-optical instabilities are observed, in contrast with laser-driven systems. Based on these results, we describe a method to quantify nonlinear properties of microwave optomechanical devices. Such a technique, available now in the quantum electro-mechanics toolbox, but completely generic, is mandatory for the development of new schemes where higher-order coupling terms are proposed as a new resource, like Quantum Non-Demolition measurements, or in the search for new fundamental quantum signatures, like Quantum Gravity. We also find that the motion imprints a wide comb of extremely narrow peaks in the microwave output field, which could also be exploited in specific microwave-based measurements, potentially limited only by the quantum noise of the optical and the mechanical fields for a ground-state cooled NEMS device.
△ Less
Submitted 24 September, 2020; v1 submitted 6 March, 2020;
originally announced March 2020.
-
Design Evaluation of Serial and Parallel sub-mK Continuous Nuclear Demagnetization Refrigerators
Authors:
D. Schmoranzer,
J. Butterworth,
S. Triqueneaux,
E. Collin,
A. Fefferman
Abstract:
We present the evaluation of two different design configurations of a two-stage PrNi$_5$ continuous nuclear demagnetization refrigerator. Serial and parallel configurations of the two stages are considered, with emphasis on the attainable cooling power at sub-mK temperatures and the impact of the design choices on the operation of the refrigerator. Numerical simulations of heat transfer in the set…
▽ More
We present the evaluation of two different design configurations of a two-stage PrNi$_5$ continuous nuclear demagnetization refrigerator. Serial and parallel configurations of the two stages are considered, with emphasis on the attainable cooling power at sub-mK temperatures and the impact of the design choices on the operation of the refrigerator. Numerical simulations of heat transfer in the setup are used to evaluate the performance of the refrigerator as well as the technological requirements for the essential thermal links. In accord with similar findings for adiabatic demagnetization refrigerators [Shirron, \emph{Cryogenics} \textbf{62}, 2014], our simulations show that the performance of both configurations improves as the thermal links improve, and that the parallel configuration yields a higher cooling power than the series design for a given thermal link resistance and sample temperature.
△ Less
Submitted 22 July, 2020; v1 submitted 3 December, 2019;
originally announced December 2019.
-
A 10 mK hermetic cell for eliminating parasitic heating in cryogen-free dilution refrigerators
Authors:
David Schmoranzer,
Sumit Kumar,
Sébastien Triqueneaux,
Xiao Liu,
Thomas Metcalf,
Glenn Jernigan,
Eddy Collin,
Andrew Fefferman
Abstract:
Cryogen-free dilution refrigerators generally simplify low temperature research but some types of samples, including superconducting qubits and other nanoelectronic devices, are affected by environmental heat sources such as stray photons or residual helium. We present the design and performance of a hermetic cell installed on the mixing chamber plate of a cryogen-free dilution refrigerator. The p…
▽ More
Cryogen-free dilution refrigerators generally simplify low temperature research but some types of samples, including superconducting qubits and other nanoelectronic devices, are affected by environmental heat sources such as stray photons or residual helium. We present the design and performance of a hermetic cell installed on the mixing chamber plate of a cryogen-free dilution refrigerator. The performance was quantified by measuring the dependence of the resonance frequency of a mechanical oscillator installed inside the cell on the mixing chamber temperature down to 10 mK. We found the expected logarithmic temperature dependence of the resonance frequency down to the lowest temperatures, demonstrating that the efficiency of the hermetic shield is significantly better than that of a simpler shield with no visible gaps.
△ Less
Submitted 8 November, 2019;
originally announced November 2019.
-
Geometrical Nonlinearity of Circular Plates and Membranes: an Alternative Method
Authors:
D. Cattiaux,
S. Kumar,
X. Zhou,
A. Fefferman,
E. Collin
Abstract:
We apply the well-established theoretical method developed for geometrical nonlinearities of micro/nano-mechanical clamped beams to circular drums. The calculation is performed under the same hypotheses, the extra difficulty being to analytically describe the (coordinate-dependent) additional stress generated in the structure by the motion. Specifically, the model applies to non-axisymmetric mode…
▽ More
We apply the well-established theoretical method developed for geometrical nonlinearities of micro/nano-mechanical clamped beams to circular drums. The calculation is performed under the same hypotheses, the extra difficulty being to analytically describe the (coordinate-dependent) additional stress generated in the structure by the motion. Specifically, the model applies to non-axisymmetric mode shapes. An analytic expression is produced for the Duffing (hardening) nonlinear coefficient, which requires only the knowledge of the mode shape functions to be evaluated. This formulation is simple to handle, and does not rely on complex numerical methods. Moreover, no hypotheses are made on the drive scheme and the nature of the in-plane stress: it is not required to be of electrostatic origin. We confront our predictions with both typical experimental devices and relevant theoretical results from the literature. Generalization of the presented method to Duffing-type mode-coupling should be a straightforward extension of this work. We believe that the presented modeling will contribute to the development of nonlinear physics implemented in 2D micro/nano-mechanical structures.
△ Less
Submitted 24 September, 2020; v1 submitted 7 October, 2019;
originally announced October 2019.
-
Niobium nitride thin films for very low temperature resistive thermometry
Authors:
Tuyen Nguyen,
Adib Tavakoli,
Sebastien Triqueneaux,
Rahul Swami,
Aki Ruhtinas,
Jeremy Gradel,
Pablo Garcia-Campos,
Klaus Hasselbach,
Aviad Frydman,
Benjamin Piot,
Mathieu Gibert,
Eddy Collin,
Olivier Bourgeois
Abstract:
We investigate thin film resistive thermometry based on metal-to-insulator-transition (niobium nitride) materials down to very low temperature. The variation of the NbN thermometer resistance have been calibrated versus temperature and magnetic field. High sensitivity in tempertaure variation detection is demonstrated through efficient temperature coefficient of resistance. The nitrogen content of…
▽ More
We investigate thin film resistive thermometry based on metal-to-insulator-transition (niobium nitride) materials down to very low temperature. The variation of the NbN thermometer resistance have been calibrated versus temperature and magnetic field. High sensitivity in tempertaure variation detection is demonstrated through efficient temperature coefficient of resistance. The nitrogen content of the niobium nitride thin films can be tuned to adjust the optimal working temperature range. In the present experiment, we show the versatility of the NbN thin film technology through applications in very different low temperature use-cases. We demonstrate that thin film resistive thermometry can be extended to temperatures below 30 mK with low electrical impedance.
△ Less
Submitted 19 July, 2019;
originally announced July 2019.
-
Detecting the "phonon wind" in superfluid $\mathrm{^4He}$ by a nanomechanical resonator
Authors:
A. M. Guenault,
A. Guthrie,
R. P. Haley,
S. Kafanov,
Yu. A. Pashkin,
G. R. Pickett,
V. Tsepelin,
D. E. Zmeev,
E. Collin,
R. Gazizulin,
O. Maillet
Abstract:
Nanoscale mechanical resonators are widely utilized to provide high sensitivity force detectors. Here we demonstrate that such high quality factor resonators immersed in superfluid \(^4\mathrm{He}\) can be excited by a modulated flux of phonons. A nanosized heater immersed in superfluid \(^4\mathrm{He}\) acts as a source of ballistic phonons in the liquid -- "phonon wind". When the modulation freq…
▽ More
Nanoscale mechanical resonators are widely utilized to provide high sensitivity force detectors. Here we demonstrate that such high quality factor resonators immersed in superfluid \(^4\mathrm{He}\) can be excited by a modulated flux of phonons. A nanosized heater immersed in superfluid \(^4\mathrm{He}\) acts as a source of ballistic phonons in the liquid -- "phonon wind". When the modulation frequency of the phonon flux matches the resonance frequency of the mechanical resonator, the motion of the latter can be excited. This ballistic thermomechanical effect can potentially open up new types of experiments in quantum fluids.
△ Less
Submitted 1 July, 2019;
originally announced July 2019.
-
Probing superfluid $^4\mathrm{He}$ with high-frequency nanomechanical resonators down to $\mathrm{mK}$ temperatures
Authors:
A. M. Guenault,
A. Guthrie,
R. P. Haley,
S. Kafanov,
Yu. A. Pashkin,
G. R. Pickett,
M. Poole,
R. Schanen,
V. Tsepelin,
D. E. Zmeev,
E. Collin,
O. Maillet,
R. Gazizulin
Abstract:
Superfluids, such as superfluid $^3\mathrm{He}$ and $^4\mathrm{He}$, exhibit a broad range of quantum phenomena and excitations which are unique to these systems. Nanoscale mechanical resonators are sensitive and versatile force detectors with the ability to operate over many orders of magnitude in dam**. Using nanomechanical-doubly clamped beams of extremely high quality factors ($Q>10^6$), we…
▽ More
Superfluids, such as superfluid $^3\mathrm{He}$ and $^4\mathrm{He}$, exhibit a broad range of quantum phenomena and excitations which are unique to these systems. Nanoscale mechanical resonators are sensitive and versatile force detectors with the ability to operate over many orders of magnitude in dam**. Using nanomechanical-doubly clamped beams of extremely high quality factors ($Q>10^6$), we probe superfluid $^4\mathrm{He}$ from the superfluid transition temperature down to $\mathrm{mK}$ temperatures at frequencies up to $11.6 \, \mathrm{MHz}$. Our studies show that nanobeam dam** is dominated by hydrodynamic viscosity of the normal component of $^4\mathrm{He}$ above $1\,\mathrm{K}$. In the temperature range $0.3-0.8\,\mathrm{K}$, the ballistic quasiparticles (phonons and rotons) determine the beams' behavior. At lower temperatures, dam** saturates and is determined either by magnetomotive losses or acoustic emission into helium. It is remarkable that all these distinct regimes can be extracted with just a single device, despite dam** changing over six orders of magnitude.
△ Less
Submitted 1 July, 2019;
originally announced July 2019.
-
On-chip thermometry for microwave optomechanics implemented in a nuclear demagnetization cryostat
Authors:
X. Zhou,
D. Cattiaux,
R. R. Gazizulin,
A. Luck,
O. Maillet,
T. Crozes,
J-F. Motte,
O. Bourgeois,
A. Fefferman,
E. Collin
Abstract:
We report on microwave optomechanics measurements performed on a nuclear adiabatic demagnetization cryostat, whose temperature is determined by accurate thermometry from below 500$~μ$K to about 1$~$Kelvin. We describe a method for accessing the on-chip temperature, building on the blue-detuned parametric instability and a standard microwave setup. The capabilities and sensitivity of both the exper…
▽ More
We report on microwave optomechanics measurements performed on a nuclear adiabatic demagnetization cryostat, whose temperature is determined by accurate thermometry from below 500$~μ$K to about 1$~$Kelvin. We describe a method for accessing the on-chip temperature, building on the blue-detuned parametric instability and a standard microwave setup. The capabilities and sensitivity of both the experimental arrangement and the developed technique are demonstrated with a very weakly coupled silicon-nitride doubly-clamped beam mode of about 4$~$MHz and a niobium on-chip cavity resonating around 6$~$GHz. We report on an unstable intrinsic driving force in the coupled microwave-mechanical system acting on the mechanics that appears below typically 100$~$mK. The origin of this phenomenon remains unknown, and deserves theoretical input. It prevents us from performing reliable experiments below typically 10-30$~$mK; however no evidence of thermal decoupling is observed, and we propose that the same features should be present in all devices sharing the microwave technology, at different levels of strengths. We further demonstrate empirically how most of the unstable feature can be annihilated, and speculate how the mechanism could be linked to atomic-scale two level systems. The described microwave/microkelvin facility is part of the EMP platform, and shall be used for further experiments within and below the millikelvin range.
△ Less
Submitted 20 April, 2022; v1 submitted 12 March, 2019;
originally announced March 2019.
-
Cryogenic broadband vibration measurement on a cryogen-free dilution refrigerator
Authors:
D. Schmoranzer,
A. Luck,
E. Collin,
A. Fefferman
Abstract:
This manuscript reports a set of acceleration measurements in the frequency range from 0 to 50 kHz performed at the mixing chamber plate (2 axes) and the top flange (3 axes) of a cryogen-free dilution refrigerator. Various configurations of the support frame and coupling to the pulse tube compressor and motor have been tested, and the dominant contribution in the spectrum of vibrations is located,…
▽ More
This manuscript reports a set of acceleration measurements in the frequency range from 0 to 50 kHz performed at the mixing chamber plate (2 axes) and the top flange (3 axes) of a cryogen-free dilution refrigerator. Various configurations of the support frame and coupling to the pulse tube compressor and motor have been tested, and the dominant contribution in the spectrum of vibrations is located, surprisingly, near 20 kHz. Finally, the efficiency of various precautions in suppressing the observed vibration levels is illustrated.
△ Less
Submitted 16 November, 2018;
originally announced November 2018.
-
Driving nanomechanical resonators by phonon flux in superfluid \(\mathbf{^4He}\)
Authors:
A. M. Guénault,
A. Guthrie,
R. P. Haley,
S. Kafanov,
Yu. A. Pashkin,
G. R. Pickett,
V. Tsepelin,
D. E. Zmeev,
E. Collin,
R. Gazizulin,
O. Maillet,
M. Arrayás,
J. L. Trueba
Abstract:
We report on nanomechanical resonators with very high-quality factors operated as mechanical probes in liquid helium \(^4\mathrm{He}\), with special attention to the superfluid regime down to millikelvin temperatures. Such resonators have been used to map out the full range of dam** mechanisms in the liquid on the nanometer scale from \(10\,\mathrm{mK}\) up to \(\sim3\,\mathrm{K}\). The high sen…
▽ More
We report on nanomechanical resonators with very high-quality factors operated as mechanical probes in liquid helium \(^4\mathrm{He}\), with special attention to the superfluid regime down to millikelvin temperatures. Such resonators have been used to map out the full range of dam** mechanisms in the liquid on the nanometer scale from \(10\,\mathrm{mK}\) up to \(\sim3\,\mathrm{K}\). The high sensitivity of these doubly-clamped beams to thermal excitations in the superfluid \(^4\mathrm{He}\) makes it possible to drive them using the momentum transfer from phonons generated by a nearby heater. This so-called "\textit{phonon wind}" is an inverse thermomechanical effect that until now has never been demonstrated, and provides the possibility to perform a new type of optomechanical experiments in quantum fluids.
△ Less
Submitted 28 June, 2019; v1 submitted 23 October, 2018;
originally announced October 2018.
-
Development of a sub-mK Continuous Nuclear Demagnetization Refrigerator
Authors:
David Schmoranzer,
Rasul Gazizulin,
Sébastien Triqueneaux,
Eddy Collin,
Andrew Fefferman
Abstract:
We present the development of a two-stage PrNi$_5$ continuous demagnetization refrigerator at the Institut Néel/CNRS and numerical simulations of its performance. The thermal model used in the simulations is discussed in detail including the likely sources of heating. We demonstrate the effects of the critical thermal links including superconducting heat switches as well as the heat conductivity o…
▽ More
We present the development of a two-stage PrNi$_5$ continuous demagnetization refrigerator at the Institut Néel/CNRS and numerical simulations of its performance. The thermal model used in the simulations is discussed in detail including the likely sources of heating. We demonstrate the effects of the critical thermal links including superconducting heat switches as well as the heat conductivity of the PrNi$_5$, accounting for the dependence of cooling power on the PrNi$_5$ rod diameter. Our simulations show that if extreme care is taken to minimize the thermal resistance between the nuclear stages, a sample temperature of 1~mK can be maintained under a 20~nW heat load.
△ Less
Submitted 3 June, 2020; v1 submitted 20 September, 2018;
originally announced September 2018.
-
Thermal coupling of silicon oscillators in cryogen-free dilution refrigerators
Authors:
David Schmoranzer,
Sumit Kumar,
Annina Luck,
Eddy Collin,
Andrew Fefferman,
Xiao Liu,
Thomas Metcalf,
Glenn Jernigan
Abstract:
Silicon double paddle osillators (DPO) have been successfully used for measuring the elastic properties of amorphous films down to 10 mK (see for example \cite{Fefferman16,Liu14}). Until now, our group has used a wet dilution refrigerator for the lowest temperature measurements. We present measurements carried out on a Bluefors cryogen-free dilution refrigerator that demonstrate an extreme sensiti…
▽ More
Silicon double paddle osillators (DPO) have been successfully used for measuring the elastic properties of amorphous films down to 10 mK (see for example \cite{Fefferman16,Liu14}). Until now, our group has used a wet dilution refrigerator for the lowest temperature measurements. We present measurements carried out on a Bluefors cryogen-free dilution refrigerator that demonstrate an extreme sensitivity of the thermal coupling of the DPO to its environment. These measurements show that it is necessary to enclose the DPO in a shield at the mixing chamber (MXC) temperature. Any gaps in the shield limit its effectiveness, even if there is no line-of-sight path to the DPO. In the absence of a cryogenic hermetic shield surrounding the DPO, turning off the pulse tube while maintaining the MXC and still temperatures leads to heating of the DPO. This demonstrates that any heating of the sample due to pulse tube vibrations is a less important effect.
△ Less
Submitted 19 September, 2018;
originally announced September 2018.
-
Silicon Vibrating Wires at Low Temperatures
Authors:
Eddy Collin,
Laure Filleau,
Thierry Fournier,
Yuriy M. Bunkov,
Henri Godfrin
Abstract:
Nowadays microfabrication techniques originating from micro-electronics enable to create mechanical objects of micron-size. The field of Micro-Electro-Mechanical devices (MEMS) is continuously expanding, with an amazingly broad range of applications at room temperature. Vibrating objects (torsional oscillators, vibrating wires) widely used at low temperatures to study quantum fluids, can be replac…
▽ More
Nowadays microfabrication techniques originating from micro-electronics enable to create mechanical objects of micron-size. The field of Micro-Electro-Mechanical devices (MEMS) is continuously expanding, with an amazingly broad range of applications at room temperature. Vibrating objects (torsional oscillators, vibrating wires) widely used at low temperatures to study quantum fluids, can be replaced advantageously by Silicon MEMS. In this letter we report on the study of Silicon vibrating wire devices. A goal-post structure covered with a metal layer is driven at resonance by the Laplace force acting on a current in a magnetic field, while the induced voltage arising from the cut magnetic flux allows to detect the motion. The characteristics of the resonance have been studied from 10 mK to 30 K, in vacuum and in $^4$He gas. In this article, we focus on the results obtained above 1.5 K, in vacuum and gas, and introduce some features observed at lower temperatures. The resonant properties can be quantitatively understood by means of simple models, from the linear regime to a highly non-linear response at strong drives. We demonstrate that the non-linearity is mostly due to the geometry of the vibrators. We also show that in our device the friction mechanisms originate in the metallic layers, and can be fully characterized. The interaction with $^4$He gas is fit to theory without adjustable parameters.
△ Less
Submitted 23 February, 2018;
originally announced February 2018.
-
Measuring frequency fluctuations in nonlinear nanomechanical resonators
Authors:
Olivier Maillet,
Xin Zhou,
Rasul R. Gazizulin,
Bojan R. Ilic,
Jeevak M. Parpia,
Olivier Bourgeois,
Andrew D. Fefferman,
Eddy Collin
Abstract:
Advances in nanomechanics within recent years have demonstrated an always expanding range of devices, from top-down structures to appealing bottom-up MoS$_2$ and graphene membranes, used for both sensing and component-oriented applications. One of the main concerns in all of these devices is frequency noise, which ultimately limits their applicability. This issue has attracted a lot of attention r…
▽ More
Advances in nanomechanics within recent years have demonstrated an always expanding range of devices, from top-down structures to appealing bottom-up MoS$_2$ and graphene membranes, used for both sensing and component-oriented applications. One of the main concerns in all of these devices is frequency noise, which ultimately limits their applicability. This issue has attracted a lot of attention recently, and the origin of this noise remains elusive up to date. In this Letter we present a very simple technique to measure frequency noise in nonlinear mechanical devices, based on the presence of bistability. It is illustrated on silicon-nitride high-stress doubly-clamped beams, in a cryogenic environment. We report on the same $T/f$ dependence of the frequency noise power spectra as reported in the literature. But we also find unexpected {\it dam** fluctuations}, amplified in the vicinity of the bifurcation points; this effect is clearly distinct from already reported nonlinear dephasing, and poses a fundamental limit on the measurement of bifurcation frequencies. The technique is further applied to the measurement of frequency noise as a function of mode number, within the same device. The relative frequency noise for the fundamental flexure $δf/f_0$ lies in the range $0.5 - 0.01~$ppm (consistent with literature for cryogenic MHz devices), and decreases with mode number in the range studied. The technique can be applied to {\it any types} of nano-mechanical structures, enabling progresses towards the understanding of intrinsic sources of noise in these devices.
△ Less
Submitted 8 June, 2018; v1 submitted 20 February, 2018;
originally announced February 2018.
-
Surface-induced near-field scaling in the Knudsen layer of a rarefied gas
Authors:
R. R. Gazizulin,
O. Maillet,
X. Zhou,
A. Maldonado Cid,
O. Bourgeois,
E. Collin
Abstract:
We report on experiments performed within the Knudsen boundary layer of a low-pressure gas. The non-invasive probe we use is a suspended nano-electro-mechanical string (NEMS), which interacts with $^4$He gas at cryogenic temperatures. When the pressure $P$ is decreased, a reduction of the dam** force below molecular friction $\propto P$ had been first reported in Phys. Rev. Lett. Vol 113, 136101…
▽ More
We report on experiments performed within the Knudsen boundary layer of a low-pressure gas. The non-invasive probe we use is a suspended nano-electro-mechanical string (NEMS), which interacts with $^4$He gas at cryogenic temperatures. When the pressure $P$ is decreased, a reduction of the dam** force below molecular friction $\propto P$ had been first reported in Phys. Rev. Lett. Vol 113, 136101 (2014) and never reproduced since. We demonstrate that this effect is independent of geometry, but dependent on temperature. Within the framework of kinetic theory, this reduction is interpreted as a rarefaction phenomenon, carried through the boundary layer by a deviation from the usual Maxwell-Boltzmann equilibrium distribution induced by surface scattering. Adsorbed atoms are shown to play a key role in the process, which explains why room temperature data fail to reproduce it.
△ Less
Submitted 20 January, 2018; v1 submitted 10 August, 2017;
originally announced August 2017.
-
Temperature Dependent Energy Levels of Electrons on Liquid Helium
Authors:
E. Collin,
W. Bailey,
P. Fozooni,
P. G. Frayne,
P. Glasson,
K. Harrabi,
M. J. Lea
Abstract:
We present measurements of the resonant microwave absorption by the Rydberg energy levels of surface state electrons on the surface of superfluid liquid helium, in the frequency range 165 - 220 GHz. The resonant frequency was strongly temperature dependent from 0.1 to 2 K. The experiments are in agreement with recent theoretical calculations of the renormalisation of the electron energy levels due…
▽ More
We present measurements of the resonant microwave absorption by the Rydberg energy levels of surface state electrons on the surface of superfluid liquid helium, in the frequency range 165 - 220 GHz. The resonant frequency was strongly temperature dependent from 0.1 to 2 K. The experiments are in agreement with recent theoretical calculations of the renormalisation of the electron energy levels due to zero-point and thermal ripplons, analogous to a condensed matter Lamb shift. The temperature-dependent contribution to the linewidth for excitation to the first excited state at 189.6 GHz is compared with other measurements and theoretical predictions.
△ Less
Submitted 23 November, 2017; v1 submitted 7 July, 2017;
originally announced July 2017.
-
Non-linear Frequency Transduction of Nano-mechanical Brownian Motion
Authors:
Olivier Maillet,
Xin Zhou,
Rasul Gazizulin,
Ana Maldonado Cid,
Martial Defoort,
Olivier Bourgeois,
Eddy Collin
Abstract:
We report on experiments addressing the non-linear interaction between a nano-mechanical mode and position fluctuations. The Duffing non-linearity transduces the Brownian motion of the mode, and of other non-linearly coupled ones, into frequency noise. This mechanism, ubiquitous to all weakly-nonlinear resonators thermalized to a bath, results in a phase diffusion process altering the motion: two…
▽ More
We report on experiments addressing the non-linear interaction between a nano-mechanical mode and position fluctuations. The Duffing non-linearity transduces the Brownian motion of the mode, and of other non-linearly coupled ones, into frequency noise. This mechanism, ubiquitous to all weakly-nonlinear resonators thermalized to a bath, results in a phase diffusion process altering the motion: two limit behaviors appear, analogous to motional narrowing and inhomogeneous broadening in NMR. Their crossover is found to depend non-trivially on the ratio of the frequency noise correlation time to its magnitude. Our measurements obtained over an unprecedented range covering the two limits match the theory of Y. Zhang and M. I. Dykman, Phys. Rev. B 92, 165419 (2015), with no free parameters. We finally discuss the fundamental bound on frequency resolution set by this mechanism, which is not marginal for bottom-up nanostructures.
△ Less
Submitted 20 October, 2017; v1 submitted 20 April, 2017;
originally announced April 2017.
-
The Universality of Thermal Transport in Amorphous Nanowires at Low Temperatures
Authors:
Adib Tavakoli,
Christophe Blanc,
Hossein Ftouni,
Kunal Lulla,
Andrew Fefferman,
Eddy Collin,
Olivier Bourgeois
Abstract:
Thermal transport properties of amorphous materials at low temperatures are governed by the interaction between phonons and localized excitations referred to as tunneling two level systems (TLS). The temperature variation of the thermal conductivity of these amorphous materials is considered as universal and is characterized by a quadratic power law. This is well described by the phenomenological…
▽ More
Thermal transport properties of amorphous materials at low temperatures are governed by the interaction between phonons and localized excitations referred to as tunneling two level systems (TLS). The temperature variation of the thermal conductivity of these amorphous materials is considered as universal and is characterized by a quadratic power law. This is well described by the phenomenological TLS model even though its microscopic explanation is still elusive. Here, by scaling down to the nanometer scale amorphous systems much below the bulk phonon-TLS mean free path, we probed the robustness of that model in restricted geometry systems. Using very sensitive thermal conductance measurements, we demonstrate that the temperature dependence of the thermal conductance of silicon nitride nanostructures remains mostly quadratic independently of the nanowire section. It is not following the cubic power law in temperature as expected in a Casimir-Ziman regime of boundary limited thermal transport. This shows a thermal transport counter intuitively dominated by phonon-TLS interactions and not by phonon-boundary scattering in the nanowires. This could be ascribed to an unexpected high density of TLS on the surfaces which still dominates the phonon diffusion processes at low temperatures and explains why the universal quadratic temperature dependence of thermal conductance still holds for amorphous nanowires.
△ Less
Submitted 24 March, 2017;
originally announced March 2017.
-
Elastic measurements of amorphous silicon films at mK temperatures
Authors:
Andrew Fefferman,
Ana Maldonado,
Eddy Collin,
Xiao Liu,
Tom Metcalf,
Glenn Jernigan
Abstract:
The low temperature properties of glass are distinct from those of crystals due to the presence of poorly understood low-energy excitations. The tunneling model proposes that these are atoms tunneling between nearby equilibria, forming tunneling two level systems (TLSs). This model is rather successful, but it does not explain the remarkably universal value of the mechanical dissipation $Q^{-1}$ n…
▽ More
The low temperature properties of glass are distinct from those of crystals due to the presence of poorly understood low-energy excitations. The tunneling model proposes that these are atoms tunneling between nearby equilibria, forming tunneling two level systems (TLSs). This model is rather successful, but it does not explain the remarkably universal value of the mechanical dissipation $Q^{-1}$ near 1 kelvin. The only known exceptions to this universality are the $Q^{-1}$ of certain thin films of amorphous silicon, carbon and germanium. Recently, it was found that $Q^{-1}$ of amorphous silicon (a-Si) films can be reduced by two orders of magnitude by increasing the temperature of the substrate during deposition. According to the tunneling model, the reduction in $Q^{-1}$ at 1 kelvin implies a reduction in $P_{0}γ^{2}$, where $P_{0}$ is the density of TLSs and $γ$ is their coupling to phonons. In this preliminary report, we demonstrate elastic measurements of a-Si films down to 20 mK. This will allow us, in future work, to determine whether $P_{0}$ or $γ$ is responsible for the reduction in $Q^{-1}$ with deposition temperature.
△ Less
Submitted 21 October, 2016;
originally announced October 2016.
-
Slippage and boundary layer probed in an almost-ideal gas by a nano-mechanical oscillator
Authors:
M. Defoort,
K. J. Lulla,
T. Crozes,
O. Maillet,
O. Bourgeois,
E. Collin
Abstract:
We have measured the interaction between $^4$He gas at 4.2$~$K and a high-quality nano-electro-mechanical string device for its first 3 symmetric modes (resonating at 2.2$~$MHz, 6.7$~$MHz and 11$~$MHz with quality factor $Q > 0.1$ million) over almost 6 orders of magnitude in pressure. This fluid can be viewed as the best experimental implementation of an almost-ideal monoatomic and inert gas whic…
▽ More
We have measured the interaction between $^4$He gas at 4.2$~$K and a high-quality nano-electro-mechanical string device for its first 3 symmetric modes (resonating at 2.2$~$MHz, 6.7$~$MHz and 11$~$MHz with quality factor $Q > 0.1$ million) over almost 6 orders of magnitude in pressure. This fluid can be viewed as the best experimental implementation of an almost-ideal monoatomic and inert gas which properties are tabulated. The experiment ranges from high pressure where the flow is of laminar Stokes-type presenting slippage, down to very low pressures where the flow is molecular. In the molecular regime, when the mean-free-path is of the order of the distance between the suspended nano-mechanical probe and the bottom of the trench we resolve for the first time the signature of the boundary (Knudsen) layer onto the measured dissipation. Our results are discussed in the framework of the most recent theories investigating boundary effects in fluids (both analytic approaches and Monte-Carlo DSMC simulations).
△ Less
Submitted 8 December, 2015;
originally announced December 2015.
-
Evidence for the role of normal-state electrons in nanoelectromechanical dam** mechanisms at very low temperatures
Authors:
K. J. Lulla,
M. Defoort,
C. Blanc,
O. Bourgeois,
E. Collin
Abstract:
We report on experiments performed at low temperatures on aluminum covered silicon nanoelectromechanical resonators. The substantial difference observed between the mechanical dissipation in the normal and superconducting states measured within the same device unambiguously demonstrates the importance of normal-state electrons in the dam** mechanism. The dissipative component becomes vanishingly…
▽ More
We report on experiments performed at low temperatures on aluminum covered silicon nanoelectromechanical resonators. The substantial difference observed between the mechanical dissipation in the normal and superconducting states measured within the same device unambiguously demonstrates the importance of normal-state electrons in the dam** mechanism. The dissipative component becomes vanishingly small at very low temperatures in the superconducting state, leading to exceptional values for the quality factor of such small silicon structures. A critical discussion is given within the framework of the standard tunneling model.
△ Less
Submitted 3 December, 2015;
originally announced December 2015.
-
Probing Bogoliubov quasiparticles in superfluid $^3$He with a 'vibrating-wire like' MEMS device
Authors:
M. Defoort,
S. Dufresnes,
S. L. Ahlstrom,
D. I. Bradley,
R. P. Haley,
A. M. Guénault,
E. A. Guise,
G. R. Pickett,
M. Poole,
A. J. Woods,
V. Tsepelin,
S. N. Fisher,
H. Godfrin,
E. Collin
Abstract:
We have measured the interaction between superfluid $^3$He-B and a micro-machined goalpost-shaped device at temperatures below $0.2\,T_c$. The measured dam** follows well the theory developed for vibrating wires, in which the Andreev reflection of quasiparticles in the flow field around the moving structure leads to a nonlinear frictional force. At low velocities the dam** force is proportiona…
▽ More
We have measured the interaction between superfluid $^3$He-B and a micro-machined goalpost-shaped device at temperatures below $0.2\,T_c$. The measured dam** follows well the theory developed for vibrating wires, in which the Andreev reflection of quasiparticles in the flow field around the moving structure leads to a nonlinear frictional force. At low velocities the dam** force is proportional to velocity while it tends to saturate for larger excitations. Above a velocity of 2.6$\,$mms$^{-1}$ the dam** abruptly increases, which is interpreted in terms of Cooper-pair breaking. Interestingly, this critical velocity is significantly lower than reported with other mechanical probes immersed in superfluid $^3$He. Furthermore, we report on a nonlinear resonance shape for large motion amplitudes that we interpret as an inertial effect due to quasiparticle friction, but other mechanisms could possibly be invoked as well.
△ Less
Submitted 3 December, 2015;
originally announced December 2015.
-
Specific heat measurement of thin suspended SiN membrane from 8 K to 300 K using the 3$ω$-V$\ddot{o}$lklein method
Authors:
Hossein Ftouni,
Dimitri Tainoff,
Jacques Richard,
Kunal Lulla,
Jean Guidi,
Eddy Collin,
Olivier Bourgeois
Abstract:
We present a specific heat measurement technique adapted to thin or very thin suspended membranes from low temperature (8 K) to 300 K. The presented device allows the measurement of the heat capacity of a 70 ng silicon nitride membrane (50 or 100 nm thick), corresponding to a heat capacity of 1.4x10$^{-10}$ J/K at 8 K and 5.1x10$^{-8}$ J/K at 300 K. Measurements are performed using the 3$ω$ method…
▽ More
We present a specific heat measurement technique adapted to thin or very thin suspended membranes from low temperature (8 K) to 300 K. The presented device allows the measurement of the heat capacity of a 70 ng silicon nitride membrane (50 or 100 nm thick), corresponding to a heat capacity of 1.4x10$^{-10}$ J/K at 8 K and 5.1x10$^{-8}$ J/K at 300 K. Measurements are performed using the 3$ω$ method coupled to the V$\ddot{o}$lklein geometry. This configuration allows the measurement of both specific heat and thermal conductivity within the same experiment. A transducer (heater/thermometer) is used to create an oscillation of the heat flux on the membrane; the voltage oscillation appearing at the third harmonic which contains the thermal information is measured using a Wheatstone bridge set-up. The heat capacity measurement is performed by measuring the variation of the 3$ω$ voltage over a wide frequency range and by fitting the experimental data using a thermal model adapted to the heat transfer across the membrane. The experimental data are compared to a regular Debye model; the specific heat exhibits features commonly seen for glasses at low temperature.
△ Less
Submitted 24 November, 2015;
originally announced November 2015.
-
In-situ comprehensive calibration of a tri-port nano-electro-mechanical device
Authors:
E. Collin,
M. Defoort,
K. Lulla,
T. Moutonet,
J. -S. Heron,
O. Bourgeois,
Yu. M. Bunkov,
H. Godfrin
Abstract:
We report on experiments performed in vacuum and at cryogenic temperatures on a tri-port nano-electro-mechanical (NEMS) device. One port is a very non-linear capacitive actuation, while the two others implement the magnetomotive scheme with a linear input force port and a (quasi-linear) output velocity port. We present an experimental method enabling a full characterization of the nanomechanical d…
▽ More
We report on experiments performed in vacuum and at cryogenic temperatures on a tri-port nano-electro-mechanical (NEMS) device. One port is a very non-linear capacitive actuation, while the two others implement the magnetomotive scheme with a linear input force port and a (quasi-linear) output velocity port. We present an experimental method enabling a full characterization of the nanomechanical device harmonic response: the non-linear capacitance function $C(x)$ is derived, and the normal parameters $k$ and $m$ (spring constant and mass) of the mode under study are measured through a careful definition of the motion (in meters) and of the applied forces (in Newtons). These results are obtained with a series of purely electric measurements performed without disconnecting/reconnecting the device, and rely only on known DC properties of the circuit, making use of a thermometric property of the oscillator itself: we use the Young modulus of the coating metal as a thermometer, and the resistivity for Joule heating. The setup requires only three connecting lines without any particular matching, enabling the preservation of a high impedance NEMS environment even at MHz frequencies. The experimental data are fit to a detailed electrical and thermal model of the NEMS device, demonstrating a complete understanding of its dynamics. These methods are quite general and can be adapted (as a whole, or in parts) to a large variety of elecromechanical devices.
△ Less
Submitted 23 November, 2015;
originally announced November 2015.
-
Nonlinear parametric amplification in a tri-port nanoelectromechanical device
Authors:
E. Collin,
T. Moutonet,
J. -S. Heron,
O. Bourgeois,
Yu. M. Bunkov,
H. Godfrin
Abstract:
We report on measurements performed at low temperatures on a nanoelectromechanical system (NEMS) under (capacitive) parametric pum**. The excitations and detection schemes are purely electrical, and enable in the present experiment the straightforward measurement of forces down to about a femtonewton, for displacements of an Angström, using standard room temperature electronics. We demonstrate t…
▽ More
We report on measurements performed at low temperatures on a nanoelectromechanical system (NEMS) under (capacitive) parametric pum**. The excitations and detection schemes are purely electrical, and enable in the present experiment the straightforward measurement of forces down to about a femtonewton, for displacements of an Angström, using standard room temperature electronics. We demonstrate that a small (linear) force applied on the device can be amplified up to more than a 100 times, while the system is {\it truly moving}. We explore the dynamics up to about 50$~$nm deflections for cantilevers about 200$~$nm thick by 3$~$$μ$m long oscillating at a frequency of 7$~$MHz. We present a generic modeling of nonlinear parametric amplification, and give analytic theoretical solutions enabling the fit of experimental results. We finally discuss the practical limits of the technique, with a particular application: the measurement of {\it anelastic dam**} in the metallic coating of the device with an exceptional resolution of about 0.5$~$\%.
△ Less
Submitted 23 November, 2015;
originally announced November 2015.
-
Modal "self-coupling" as a sensitive probe for nanomechanical detection
Authors:
M. Defoort,
K. J. Lulla,
C. Blanc,
O. Bourgeois,
A. D. Armour,
E. Collin
Abstract:
We present a high-sensitivity measurement technique for mechanical nanoresonators. Due to intrinsic nonlinear effects, different flexural modes of a nanobeam can be coupled while driving each of them on resonance. This mode-coupling scheme is dispersive and one mode resonance shifts with respect to the motional amplitude of the other. The same idea can be implemented on a {\it single} mode, exciti…
▽ More
We present a high-sensitivity measurement technique for mechanical nanoresonators. Due to intrinsic nonlinear effects, different flexural modes of a nanobeam can be coupled while driving each of them on resonance. This mode-coupling scheme is dispersive and one mode resonance shifts with respect to the motional amplitude of the other. The same idea can be implemented on a {\it single} mode, exciting it with two slightly detuned signals. This two-tone scheme is used here to measure the resonance lineshape of one mode through a frequency shift in the response of the device. The method acts as an amplitude-to-frequency transduction which ultimately suffers only from phase noise of the local oscillator used and of the nanomechanical device itself. We also present a theory which reproduces the data without free parameters.
△ Less
Submitted 23 November, 2015;
originally announced November 2015.
-
Classical decoherence in a nanomechanical resonator
Authors:
Olivier Maillet,
Frantisek Vavrek,
Andrew D. Fefferman,
Olivier Bourgeois,
Eddy Collin
Abstract:
Decoherence is an essential mechanism that defines the boundary between classical and quantum behaviours, while imposing technological bounds for quantum devices. Little is known about quantum coherence of mechanical systems, as opposed to electromagnetic degrees of freedom. But decoherence can also be thought of in a purely classical context, as the loss of phase coherence in the classical phase…
▽ More
Decoherence is an essential mechanism that defines the boundary between classical and quantum behaviours, while imposing technological bounds for quantum devices. Little is known about quantum coherence of mechanical systems, as opposed to electromagnetic degrees of freedom. But decoherence can also be thought of in a purely classical context, as the loss of phase coherence in the classical phase space. Indeed the bridge between quantum and classical physics is under intense investigation, using in particular classical nanomechanical analogues of quantum phenomena. In the present work, by separating pure dephasing from dissipation, we quantitatively model the classical decoherence of a mechanical resonator: through the experimental control of frequency fluctuations, we engineer artificial dephasing. Building on the fruitful analogy introduced between spins/quantum bits and nanomechanical modes, we report on the methods available to define pure dephasing in these systems, while demonstrating the intrinsic almost-ideal properties of silicon-nitride beams. These experimental and theoretical results, at the boundary between classical nanomechanics and quantum information fields, are prerequisite in the understanding of decoherence processes in mechanical devices, both classical and quantum.
△ Less
Submitted 25 October, 2017; v1 submitted 6 November, 2015;
originally announced November 2015.
-
The thermal conductivity of silicon nitride membranes is not sensitive to stress
Authors:
Hossein Ftouni,
Christophe Blanc,
Dimitri Tainoff,
Andrew D. Fefferman,
Martial Defoort,
Kunal J. Lulla,
Jacques Richard,
Eddy Collin,
Olivier Bourgeois
Abstract:
We have measured the thermal properties of suspended membranes from 10 K to 300 K for two amplitudes of internal stress (about 0.1 GPa and 1 GPa) and for two different thicknesses (50 nm and 100 nm). The use of the original 3 ω-Volklein method has allowed the extraction of both the specific heat and the thermal conductivity of each SiN membrane over a wide temperature range. The mechanical propert…
▽ More
We have measured the thermal properties of suspended membranes from 10 K to 300 K for two amplitudes of internal stress (about 0.1 GPa and 1 GPa) and for two different thicknesses (50 nm and 100 nm). The use of the original 3 ω-Volklein method has allowed the extraction of both the specific heat and the thermal conductivity of each SiN membrane over a wide temperature range. The mechanical properties of the same substrates have been measured at helium temperatures using nanomechanical techniques. Our measurements show that the thermal transport in freestanding SiN membranes is not affected by the presence of internal stress. Consistently, mechanical dissipation is also unaffected even though Qs increase with increasing tensile stress. We thus demonstrate that the theory developed by Wu and Yu [Phys. Rev. B 84, 174109 (2011)] does not apply to this amorphous material in this stress range. On the other hand, our results can be viewed as a natural consequence of the "dissipation dilution" argument [Y. L. Huang and P. R. Saulson, Rev. Sci. Instrum. 69, 544 (1998)] which has been introduced in the context of mechanical dam**.
△ Less
Submitted 5 June, 2015;
originally announced June 2015.
-
Scaling laws for the bifurcation-escape rate in a nanomechanical resonator
Authors:
Martial Defoort,
Vadim Puller,
Olivier Bourgeois,
Fabio Pistolesi,
Eddy Collin
Abstract:
We report on experimental and theoretical studies of the fluctuation-induced escape time from a metastable state of a nanomechanical Duffing resonator in cryogenic environment. By tuning in situ the non-linear coefficient $γ$ we could explore a wide range of the parameter space around the bifurcation point, where the metastable state becomes unstable. We measured in a relaxation process the distri…
▽ More
We report on experimental and theoretical studies of the fluctuation-induced escape time from a metastable state of a nanomechanical Duffing resonator in cryogenic environment. By tuning in situ the non-linear coefficient $γ$ we could explore a wide range of the parameter space around the bifurcation point, where the metastable state becomes unstable. We measured in a relaxation process the distribution of the escape times. We have been able to verify its exponential distribution and extract the escape rate $Γ$. We investigated the scaling of $Γ$ with respect to the distance to the bifurcation point and $γ$, finding an unprecedented quantitative agreement with the theoretical description of the stochastic problem. Simple power scaling laws turn out to hold in a large region of the parameter's space, as anticipated by recent theoretical predictions. These unique findings, implemented in a model dynamical system, are relevant to all systems experiencing under-damped saddle-node bifurcation.
△ Less
Submitted 23 November, 2015; v1 submitted 24 September, 2014;
originally announced September 2014.