-
Fundamental Neutron Physics: a White Paper on Progress and Prospects in the US
Authors:
R. Alarcon,
A. Aleksandrova,
S. Baeßler,
D. H. Beck,
T. Bhattacharya,
M. Blatnik,
T. J. Bowles,
J. D. Bowman,
J. Brewington,
L. J. Broussard,
A. Bryant,
J. F. Burdine,
J. Caylor,
Y. Chen,
J. H. Choi,
L. Christie,
T. E. Chupp,
V. Cianciolo,
V. Cirigliano,
S. M. Clayton,
B. Collett,
C. Crawford,
W. Dekens,
M. Demarteau,
D. DeMille
, et al. (66 additional authors not shown)
Abstract:
Fundamental neutron physics, combining precision measurements and theory, probes particle physics at short range with reach well beyond the highest energies probed by the LHC. Significant US efforts are underway that will probe BSM CP violation with orders of magnitude more sensitivity, provide new data on the Cabibbo anomaly, more precisely measure the neutron lifetime and decay, and explore hadr…
▽ More
Fundamental neutron physics, combining precision measurements and theory, probes particle physics at short range with reach well beyond the highest energies probed by the LHC. Significant US efforts are underway that will probe BSM CP violation with orders of magnitude more sensitivity, provide new data on the Cabibbo anomaly, more precisely measure the neutron lifetime and decay, and explore hadronic parity violation. World-leading results from the US Fundamental Neutron Physics community since the last Long Range Plan, include the world's most precise measurement of the neutron lifetime from UCN$τ$, the final results on the beta-asymmetry from UCNA and new results on hadronic parity violation from the NPDGamma and n-${^3}$He runs at the FNPB (Fundamental Neutron Physics Beamline), precision measurement of the radiative neutron decay mode and n-${}^4$He at NIST. US leadership and discovery potential are ensured by the development of new high-impact experiments including BL3, Nab, LANL nEDM and nEDM@SNS. On the theory side, the last few years have seen results for the neutron EDM from the QCD $θ$ term, a factor of two reduction in the uncertainty for inner radiative corrections in beta-decay which impacts CKM unitarity, and progress on {\it ab initio} calculations of nuclear structure for medium-mass and heavy nuclei which can eventually improve the connection between nuclear and nucleon EDMs. In order to maintain this exciting program and capitalize on past investments while also pursuing new ideas and building US leadership in new areas, the Fundamental Neutron Physics community has identified a number of priorities and opportunities for our sub-field covering the time-frame of the last Long Range Plan (LRP) under development. This white paper elaborates on these priorities.
△ Less
Submitted 17 August, 2023;
originally announced August 2023.
-
Recoil-Order and Radiative Corrections to the aCORN Experiment
Authors:
F. E. Wietfeldt,
W. A. Byron,
B. Collett,
M. S. Dewey,
T. R. Gentile,
F. Gluck,
M. T. Hassan,
G. L. Jones,
A. Komives,
J. S. Nico,
E. J. Stephenson
Abstract:
The aCORN experiment measures the electron-antineutrino $a$-coefficient in free neutron decay. We update the previous aCORN results to include radiative and recoil corrections to first order, and discuss a key issue in the comparison of results from different $a$-coefficient experimental methods when these effects are considered. The corrected combined result is…
▽ More
The aCORN experiment measures the electron-antineutrino $a$-coefficient in free neutron decay. We update the previous aCORN results to include radiative and recoil corrections to first order, and discuss a key issue in the comparison of results from different $a$-coefficient experimental methods when these effects are considered. The corrected combined result is $\overline{a} = -0.10779 \pm 0.00125\, ({\rm stat}) \pm 0.00133\, ({\rm sys})$, averaged over the full Fermi neutron beta spectrum. The corresponding corrected result for the ratio of weak coupling constants $λ= G_A/G_V$ is $λ= -1.2712 \pm 0.0061$. This improves agreement with previous $a$-coefficient experiments, in particular the 2020 aSPECT result
△ Less
Submitted 1 March, 2024; v1 submitted 26 June, 2023;
originally announced June 2023.
-
Measurement of the neutron decay electron-antineutrino angular correlation by the aCORN experiment
Authors:
M. T. Hassan,
W. A. Byron,
G. Darius,
C. DeAngelis,
F. E. Wietfeldt,
B. Collett,
G. L. Jones,
A. Komives,
G. Noid,
E. J. Stephenson,
F. Bateman,
M. S. Dewey,
T. R. Gentile,
M. P. Mendenhall,
J. S. Nico
Abstract:
The aCORN experiment measures the neutron decay electron-antineutrino correlation ($a$-coefficient) using a novel method based on an asymmetry in proton time-of-flight for events where the beta electron and recoil proton are detected in delayed coincidence. We report the data analysis and result from the second run at the NIST Center for Neutron Research, using the high-flux cold neutron beam on t…
▽ More
The aCORN experiment measures the neutron decay electron-antineutrino correlation ($a$-coefficient) using a novel method based on an asymmetry in proton time-of-flight for events where the beta electron and recoil proton are detected in delayed coincidence. We report the data analysis and result from the second run at the NIST Center for Neutron Research, using the high-flux cold neutron beam on the new NG-C neutron guide end position: $a = -0.10758 \pm 0.00136 (\mbox{stat}) \pm 0.00148 (\mbox{sys})$. This is consistent within uncertainties with the result from the first aCORN run on the NG-6 cold neutron beam. Combining the two aCORN runs we obtain $a = -0.10782 \pm 0.00124 (\mbox{stat}) \pm 0.00133 (\mbox{sys})$, which has an overall relative standard uncertainty of 1.7 \%. The corresponding result for the ratio of weak coupling constants $λ= G_A/G_V$ is $λ= -1.2796\pm 0.0062$.
△ Less
Submitted 28 December, 2020;
originally announced December 2020.
-
Neutron Polarimetry Using a Polarized 3He Cell for the aCORN Experiment
Authors:
B. C. Schafer,
W. A. Byron,
W. C. Chen,
B. Collett,
M. S. Dewey,
T. R. Gentile,
Md. T. Hassan,
G. L. Jones,
A. Komives,
F. E. Wietfeldt
Abstract:
The neutron polarization of the NG-C beamline at the NIST Center for Neutron Research was measured as part of the aCORN neutron beta decay experiment. Neutron transmission through a polarized 3He spin filter cell was recorded while adiabatic fast passage (AFP) nuclear magnetic resonance (NMR) reversed the polarization direction of the 3He in an eight-step sequence to account for drifts. The depend…
▽ More
The neutron polarization of the NG-C beamline at the NIST Center for Neutron Research was measured as part of the aCORN neutron beta decay experiment. Neutron transmission through a polarized 3He spin filter cell was recorded while adiabatic fast passage (AFP) nuclear magnetic resonance (NMR) reversed the polarization direction of the 3He in an eight-step sequence to account for drifts. The dependence of the neutron transmission on the spin filter direction was used to calculate the neutron polarization. The time dependent transmission was fit to a model which included the neutron spectrum, and 3He polarization losses from spin relaxation and AFP-NMR. The polarization of the NG-C beamline was found to be ${\mid}P_\mathrm{n}{\mid} \leq 4\times 10^{-4}$ with 90 % confidence.
△ Less
Submitted 25 September, 2020; v1 submitted 8 September, 2020;
originally announced September 2020.
-
Measurement of the electron-antineutrino correlation in neutron beta decay: aCORN experiment
Authors:
F. E. Wietfeldt,
W. A. Byron,
G. Darius,
C. R. DeAngelis,
M. T. Hassan,
M. S. Dewey,
M. P. Mendenhall,
J. S. Nico,
B. Collett,
G. L. Jones,
A. Komives,
E. J. Stephenson
Abstract:
The aCORN experiment uses a novel asymmetry method to measure the electron-antineutrino correlation (a-coefficient) in free neutron decay that does not require precision proton spectroscopy. aCORN completed two physics runs at the NIST Center for Neutron Research. The first run on the NG-6 beam line in 2013--2014 obtained the result a = 0.1090 +/- 0.0030 (stat) +/- 0.0028 (sys), a total uncertaint…
▽ More
The aCORN experiment uses a novel asymmetry method to measure the electron-antineutrino correlation (a-coefficient) in free neutron decay that does not require precision proton spectroscopy. aCORN completed two physics runs at the NIST Center for Neutron Research. The first run on the NG-6 beam line in 2013--2014 obtained the result a = 0.1090 +/- 0.0030 (stat) +/- 0.0028 (sys), a total uncertainty of 3.8%. The second run on the new NG-C high flux beam line promises an improvement in precision to <2%.
△ Less
Submitted 1 October, 2018;
originally announced October 2018.
-
aCORN: an experiment to measure the electron-antineutrino correlation coefficient in free neutron decay
Authors:
B. Collett,
F. Bateman,
W. K. Bauder,
J. Byrne,
W. A. Byron,
W. Chen,
G. Darius,
C. DeAngelis,
M. S. Dewey,
T. R. Gentile,
M. T. Hassan,
G. L. Jones,
A. Komives,
A. Laptev,
M. P. Mendenhall,
J. S. Nico,
G. Noid,
H. Park,
E. J. Stephenson,
I. Stern,
K. J. S. Stockton,
C. Trull,
F. E. Wietfeldt,
B. G. Yerozolimsky
Abstract:
We describe an apparatus used to measure the electron-antineutrino angular correlation coefficient in free neutron decay. The apparatus employs a novel measurement technique in which the angular correlation is converted into a proton time-of-flight asymmetry that is counted directly, avoiding the need for proton spectroscopy. Details of the method, apparatus, detectors, data acquisition, and data…
▽ More
We describe an apparatus used to measure the electron-antineutrino angular correlation coefficient in free neutron decay. The apparatus employs a novel measurement technique in which the angular correlation is converted into a proton time-of-flight asymmetry that is counted directly, avoiding the need for proton spectroscopy. Details of the method, apparatus, detectors, data acquisition, and data reduction scheme are presented, along with a discussion of the important systematic effects.
△ Less
Submitted 21 February, 2017; v1 submitted 17 January, 2017;
originally announced January 2017.
-
The aCORN Backscatter-Suppressed Beta Spectrometer
Authors:
M. T. Hassan,
F. Bateman,
B. Collett,
G. Darius,
C. DeAngelis,
M. S. Dewey,
G. L. Jones,
A. Komives,
A. Laptev,
M. P. Mendenhall,
J. S. Nico,
G. Noid,
E. J. Stephenson,
I. Stern,
C. Trull,
F. E. Wietfeldt
Abstract:
Backscatter of electrons from a beta spectrometer, with incomplete energy deposition, can lead to undesirable effects in many types of experiments. We present and discuss the design and operation of a backscatter-suppressed beta spectrometer that was developed as part of a program to measure the electron-antineutrino correlation coefficient in neutron beta decay (aCORN). An array of backscatter ve…
▽ More
Backscatter of electrons from a beta spectrometer, with incomplete energy deposition, can lead to undesirable effects in many types of experiments. We present and discuss the design and operation of a backscatter-suppressed beta spectrometer that was developed as part of a program to measure the electron-antineutrino correlation coefficient in neutron beta decay (aCORN). An array of backscatter veto detectors surrounds a plastic scintillator beta energy detector. The spectrometer contains an axial magnetic field gradient, so electrons are efficiently admitted but have a low probability for esca** back through the entrance after backscattering. The design, construction, calibration, and performance of the spectrometer are discussed.
△ Less
Submitted 25 January, 2017; v1 submitted 17 January, 2017;
originally announced January 2017.
-
What Brown saw and you can too
Authors:
Philip Pearle,
Kenneth Bart,
David Bilderback,
Brian Collett,
Dara Newman,
Scott Samuels
Abstract:
A discussion is given of Robert Brown's original observations of particles ejected by pollen of the plant \textit{Clarkia pulchella} undergoing what is now called Brownian motion. We consider the nature of those particles, and how he misinterpreted the Airy disc of the smallest particles to be universal organic building blocks. Relevant qualitative and quantitative investigations with a modern mic…
▽ More
A discussion is given of Robert Brown's original observations of particles ejected by pollen of the plant \textit{Clarkia pulchella} undergoing what is now called Brownian motion. We consider the nature of those particles, and how he misinterpreted the Airy disc of the smallest particles to be universal organic building blocks. Relevant qualitative and quantitative investigations with a modern microscope and with a "homemade" single lens microscope similar to Brown's, are presented.
△ Less
Submitted 17 September, 2010; v1 submitted 30 July, 2010;
originally announced August 2010.
-
Wavefunction Collapse and Random Walk
Authors:
Brian Collett,
Philip Pearle
Abstract:
Wavefunction collapse models modify Schrodinger's equation so that it describes the rapid evolution of a superposition of macroscopically distinguishable states to one of them. This provides a phenomenological basis for a physical resolution to the so-called "measurement problem." Such models have experimentally testable differences from standard quantum theory. The most well developed such mode…
▽ More
Wavefunction collapse models modify Schrodinger's equation so that it describes the rapid evolution of a superposition of macroscopically distinguishable states to one of them. This provides a phenomenological basis for a physical resolution to the so-called "measurement problem." Such models have experimentally testable differences from standard quantum theory. The most well developed such model at present is the Continuous Spontaneous Localization (CSL) model in which a fluctuating classical field interacts with particles to cause collapse. One "side effect" of this interaction is that the field imparts momentum to particles, causing a small blob of matter to undergo random walk. Here we explore this in order to supply predictions which could be experimentally tested. We examine the translational diffusion of a sphere and a disc, and the rotational diffusion of a disc, according to CSL. For example, we find that a disc of radius 2 cdot 10^{-5} cm and thickness 0.5 cdot 10^{-5} cm diffuses through 2 pi rad in about 70sec (this assumes the "standard" CSL parameter values). The comparable rms diffusion of standard quantum theory is smaller than this by a factor 10^-3. At the reported pressure of < 5 cdot10^{-17} Torr, achieved at 4.2^{circ} K, the mean time between air molecule collisions with the disc is approximately 45min (and the diffusion caused by photon collisons is utterly negligible). This is ample time for observation of the putative CSL diffusion over a wide range of parameters.
This encourages consideration of how such an experiment may actually be performed, and the paper closes with some thoughts on this subject
△ Less
Submitted 1 August, 2002;
originally announced August 2002.