Novel Resistive-Plate WELL sampling element for (S)DHCAL
Authors:
S. Bressler,
P. Bhattacharya,
A. Breskin,
A. E. C. Coimbra,
D. Shaked-Renous,
A. Tesi,
L. Moler,
M. Chefdeville,
G. Vouters,
J. Karyotakis,
C. Drancourt,
M. Titov,
T. Geralis
Abstract:
Digital and Semi-Digital Hadronic Calorimeters (S)DHCAL were suggested for future Colliders as part of the particle-flow concept. Though studied mostly with RPC-based techniques, investigations have shown that MPGD-based sampling elements could outperform. An attractive, industry-produced, robust, particle-tracking detector for large-area coverage, e.g. in (S)DHCAL, could be the novel single-stage…
▽ More
Digital and Semi-Digital Hadronic Calorimeters (S)DHCAL were suggested for future Colliders as part of the particle-flow concept. Though studied mostly with RPC-based techniques, investigations have shown that MPGD-based sampling elements could outperform. An attractive, industry-produced, robust, particle-tracking detector for large-area coverage, e.g. in (S)DHCAL, could be the novel single-stage Resistive Plate WELL (RPWELL). It is a single-sided THGEM coupled to the segmented readout electrode through a sheet of large bulk resistivity. We summarize here the preliminary test-beam results obtained with 6.5 mm thick (incl. electronics) {$48 \times 48\,\mathrm{cm^2}$}~RPWELL detectors. Two configurations are considered: a standalone RPWELL detector studied with 150 GeV muons and high-rate pions beams and RPWELL sampling element investigated within a small-(S)DHCAL prototype consisting of 7 resistive MICROMEGAS sampling elements followed by 5 RPWELL ones. The sampling elements were equipped with a Semi-Digital readout electronics based on the MICROROC chip.
△ Less
Submitted 26 September, 2019; v1 submitted 11 April, 2019;
originally announced April 2019.
-
Measurements of charging-up processes in THGEM-based particle detectors
Authors:
M. Pitt,
P. M. M. Correia,
S. Bressler,
A. E. C. Coimbra,
D. Shaked Renous,
C. D. R. Azevedo,
J. F. C. A. Veloso,
A. Breskin
Abstract:
The time-dependent gain variation of detectors incorporating Thick Gas Electron Multipliers (THGEM) electrodes was studied in the context of charging-up processes of the electrode's insulating surfaces. An experimental study was performed to examine model-simulation results of the aforementioned phenomena, under various experimental conditions. The results indicate that in a stable detector's envi…
▽ More
The time-dependent gain variation of detectors incorporating Thick Gas Electron Multipliers (THGEM) electrodes was studied in the context of charging-up processes of the electrode's insulating surfaces. An experimental study was performed to examine model-simulation results of the aforementioned phenomena, under various experimental conditions. The results indicate that in a stable detector's environment, the gain stabilization process is mainly affected by the charging-up of the detector's insulating surfaces caused by the avalanche charges. The charging-up is a transient effect, occurring during the detector's initial operation period; it does not affect its long-term operation. The experimental results are consistent with the outcome of model-simulations.
△ Less
Submitted 9 January, 2018; v1 submitted 1 January, 2018;
originally announced January 2018.
-
Fast-neutron and gamma-ray imaging with a capillary liquid xenon converter coupled to a gaseous photomultiplier
Authors:
I. Israelashvili,
A. E. C. Coimbra,
D. Vartsky,
L. Arazi,
S. Shchemelinin,
E. N. Caspi,
A. Breskin
Abstract:
Gamma-ray and fast-neutron imaging was performed with a novel liquid xenon (LXe) scintillation detector read out by a Gaseous Photomultiplier (GPM). The 100 mm diameter detector prototype comprised a capillary-filled LXe converter/scintillator, coupled to a triple-THGEM imaging-GPM, with its first electrode coated by a CsI UV-photocathode, operated in Ne/5%CH4 cryogenic temperatures. Radiation loc…
▽ More
Gamma-ray and fast-neutron imaging was performed with a novel liquid xenon (LXe) scintillation detector read out by a Gaseous Photomultiplier (GPM). The 100 mm diameter detector prototype comprised a capillary-filled LXe converter/scintillator, coupled to a triple-THGEM imaging-GPM, with its first electrode coated by a CsI UV-photocathode, operated in Ne/5%CH4 cryogenic temperatures. Radiation localization in 2D was derived from scintillation-induced photoelectron avalanches, measured on the GPM's segmented anode. The localization properties of Co-60 gamma-rays and a mixed fast-neutron/gamma-ray field from an AmBe neutron source were derived from irradiation of a Pb edge absorber. Spatial resolutions of 12+/-2 mm and 10+/-2 mm (FWHM) were reached with Co-60 and AmBe sources, respectively. The experimental results are in good agreement with GEANT4 simulations. The calculated ultimate expected resolutions for our application-relevant 4.4 and 15.1 MeV gamma-rays and 1-15 MeV neutrons are 2-4 mm and ~2 mm (FWHM), respectively. These results indicate the potential applicability of the new detector concept to Fast-Neutron Resonance Radiography (FNRR) and Dual-Discrete-Energy Gamma Radiography (DDEGR) of large objects.
△ Less
Submitted 15 July, 2017;
originally announced July 2017.
-
On the localization properties of an RPWELL gas-avalanche detector
Authors:
Luca Moleri,
Purba Bhattacharya,
Artur E. C. Coimbra,
Amos Breskin,
Shikma Bressler
Abstract:
A study of the localization properties of a single-element Resistive Plate WELL (RPWELL) detector is presented. The detector comprises of a single-sided THick Gaseous Electron Multiplier (THGEM) coupled to a segmented readout anode through a doped silicate-glass plate of 10$^{10}$ $Ω\cdot$cm bulk resistivity. Operated in ambient Ne/(5$\%$CH$_4$) gas, the detector has been investigated with 150 GeV…
▽ More
A study of the localization properties of a single-element Resistive Plate WELL (RPWELL) detector is presented. The detector comprises of a single-sided THick Gaseous Electron Multiplier (THGEM) coupled to a segmented readout anode through a doped silicate-glass plate of 10$^{10}$ $Ω\cdot$cm bulk resistivity. Operated in ambient Ne/(5$\%$CH$_4$) gas, the detector has been investigated with 150 GeV muons at CERN-SPS. Signals induced through the resistive plate on anode readout strips were recorded with APV25/SRS electronics. The experimental results are compared with that of Monte Carlo simulations. The effects of various physics phenomena on the position resolution are discussed. The measured position resolution in the present configuration is 0.28 mm RMS - compatible with the holes-pattern of the multiplier. Possible ways for improving the detector position resolution are suggested.
△ Less
Submitted 16 August, 2017; v1 submitted 1 July, 2017;
originally announced July 2017.
-
In-beam evaluation of a medium-size Resistive-Plate WELL gaseous particle detector
Authors:
L. Moleri,
F. D. Amaro,
L. Arazi,
C. D. R. Azevedo,
A. Breskin,
A. E. C. Coimbra,
E. Oliveri,
F. A. Pereira,
D. Shaked Renous,
J. Schaarschmidt,
J. M. F. dos Santos,
J. F. C. A. Veloso,
S. Bressler
Abstract:
In-beam evaluation of a fully-equipped medium-size 30$\times$30 cm$^2$ Resistive Plate WELL (RPWELL) detector is presented. It consists here of a single element gas-avalanche multiplier with Semitron ESD225 resistive plate, 1 cm$^2$ readout pads and APV25/SRS electronics. Similarly to previous results with small detector prototypes, stable operation at high detection efficiency (>98%) and low aver…
▽ More
In-beam evaluation of a fully-equipped medium-size 30$\times$30 cm$^2$ Resistive Plate WELL (RPWELL) detector is presented. It consists here of a single element gas-avalanche multiplier with Semitron ESD225 resistive plate, 1 cm$^2$ readout pads and APV25/SRS electronics. Similarly to previous results with small detector prototypes, stable operation at high detection efficiency (>98%) and low average pad multiplicity (~1.2) were recorded with 150 GeV muon and high-rate pion beams, in Ne/(5%CH$_4$), Ar/(5%CH$_4$) and Ar/(7%CO$_2$). This is an important step towards the realization of robust detectors suitable for applications requiring large-area coverage; among them Digital Hadron Calorimetry.
△ Less
Submitted 8 September, 2016; v1 submitted 9 July, 2016;
originally announced July 2016.
-
First results of a large-area cryogenic gaseous photomultiplier coupled to a dual-phase liquid xenon TPC
Authors:
L. Arazi,
A. E. C. Coimbra,
E. Erdal,
I. Israelashvili,
M. L. Rappaport,
S. Shchemelinin,
D. Vartsky,
J. M. F. dos Santos,
A. Breskin
Abstract:
We discuss recent advances in the development of cryogenic gaseous photomultipliers (GPM), for possible use in dark matter and other rare-event searches using noble-liquid targets. We present results from a 10 cm diameter GPM coupled to a dual-phase liquid xenon (LXe) TPC, demonstrating - for the first time - the feasibility of recording both primary ("S1") and secondary ("S2") scintillation signa…
▽ More
We discuss recent advances in the development of cryogenic gaseous photomultipliers (GPM), for possible use in dark matter and other rare-event searches using noble-liquid targets. We present results from a 10 cm diameter GPM coupled to a dual-phase liquid xenon (LXe) TPC, demonstrating - for the first time - the feasibility of recording both primary ("S1") and secondary ("S2") scintillation signals. The detector comprised a triple Thick Gas Electron Multiplier (THGEM) structure with cesium iodide photocathode on the first element; it was shown to operate stably at 180 K with gains above 10^5, providing high single-photon detection efficiency even in the presence of large alpha particle-induced S2 signals comprising thousands of photoelectrons. S1 scintillation signals were recorded with a time resolution of 1.2 ns (RMS). The energy resolution (σ/E) for S2 electroluminescence of 5.5 MeV alpha particles was ~9%, which is comparable to that obtained in the XENON100 TPC with PMTs. The results are discussed within the context of potential GPM deployment in future multi-ton noble-liquid detectors.
△ Less
Submitted 3 August, 2015;
originally announced August 2015.
-
Liquid Hole Multipliers: bubble-assisted electroluminescence in liquid xenon
Authors:
L. Arazi,
E. Erdal,
A. E. C. Coimbra,
M. L. Rappaport,
D. Vartsky,
V. Chepel,
A. Breskin
Abstract:
In this work we discuss the mechanism behind the large electroluminescence signals observed at relatively low electric fields in the holes of a Thick Gas Electron Multiplier (THGEM) electrode immersed in liquid xenon. We present strong evidence that the scintillation light is generated in xenon bubbles trapped below the THGEM holes. The process is shown to be remarkably stable over months of opera…
▽ More
In this work we discuss the mechanism behind the large electroluminescence signals observed at relatively low electric fields in the holes of a Thick Gas Electron Multiplier (THGEM) electrode immersed in liquid xenon. We present strong evidence that the scintillation light is generated in xenon bubbles trapped below the THGEM holes. The process is shown to be remarkably stable over months of operation, providing - under specific thermodynamic conditions - energy resolution similar to that of present dual-phase liquid xenon experiments. The observed mechanism may serve as the basis for the development of Liquid Hole Multipliers (LHMs), capable of producing local charge-induced electroluminescence signals in large-volume single-phase noble-liquid detectors for dark matter and neutrino physics experiments.
△ Less
Submitted 13 May, 2015; v1 submitted 9 May, 2015;
originally announced May 2015.
-
First observation of liquid-xenon proportional electroluminescence in THGEM holes
Authors:
L. Arazi,
A. E. C. Coimbra,
R. Itay,
H. Landsman,
L. Levinson,
M. L. Rappaport,
D. Vartsky,
A. Breskin
Abstract:
Radiation-induced proportional-electroluminescence UV signals, emitted from the holes of a Thick Gas Electron Multiplier (THGEM) electrode immersed in liquid xenon, were recorded with a PMT for the first time. Significant photon yields were observed using a 0.4 mm thick electrode with 0.3 mm diameter holes; at 2 kV across the THGEM the photon yield was estimated to be ~600 UV photons/electron over…
▽ More
Radiation-induced proportional-electroluminescence UV signals, emitted from the holes of a Thick Gas Electron Multiplier (THGEM) electrode immersed in liquid xenon, were recorded with a PMT for the first time. Significant photon yields were observed using a 0.4 mm thick electrode with 0.3 mm diameter holes; at 2 kV across the THGEM the photon yield was estimated to be ~600 UV photons/electron over 4pi This may pave the way towards the realization of novel single-phase noble-liquid radiation detectors incorporating liquid hole-multipliers (LHM); their concept is presented.
△ Less
Submitted 15 October, 2013;
originally announced October 2013.
-
Hybrid Multi Micropattern Gaseous Photomultiplier for detection of liquid-xenon scintillation
Authors:
Samuel Duval,
Lior Arazi,
Amos Breskin,
Ranny Budnik,
Wan-Ting Chen,
Hervé Carduner,
A. E. C. Coimbra,
Marco Cortesi,
Roy Kaner,
Jean-Pierre Cussonneau,
Jérôme Donnard,
Jacob Lamblin,
Olivier Lemaire,
Patrick Le Ray,
J. A. M. Lopes,
Abdul-Fattah Mohamad Hadi,
Eric Morteau,
Tugdual Oger,
J. M. F. dos Santos,
Luca Scotto Lavina,
Jean-Sébastien Stutzmann,
Dominique Thers
Abstract:
Gaseous PhotoMultipliers (GPM) are a very promising alternative of vacuum PMTs especially for large-size noble-liquid detectors in the field of Functional Nuclear Medical Imaging and Direct Dark Matter Detection. We present recent characterization results of a Hybrid-GPM made of three Micropattern Gaseous Structures; a Thick Gaseous Electron Multiplier (THGEM), a Parallel Ionization Multiplier (PI…
▽ More
Gaseous PhotoMultipliers (GPM) are a very promising alternative of vacuum PMTs especially for large-size noble-liquid detectors in the field of Functional Nuclear Medical Imaging and Direct Dark Matter Detection. We present recent characterization results of a Hybrid-GPM made of three Micropattern Gaseous Structures; a Thick Gaseous Electron Multiplier (THGEM), a Parallel Ionization Multiplier (PIM) and a MICROMesh GAseous Structure (MICROMEGAS),operating in Ne/CF4 (90:10). Gain values close to 10^7 were recorded in this mixture, with 5.9keV x-rays at 1100 mbar, both at room temperature and at that of liquid xenon (T = 171K). The results are discussed in term of scintillation detection. While the present multiplier was investigated without photocathode, complementary results of photoextraction from CsI UV photocathodes are presented in Ne/CH4 (95:5) and CH4 in cryogenic conditions.
△ Less
Submitted 27 October, 2011;
originally announced October 2011.
-
CsI-THGEM gaseous photomultipliers for RICH and noble-liquid detectors
Authors:
A. Breskin,
V. Peskov,
M. Cortesi,
R. Budnik,
R. Chechik,
S. Duval,
D. Thers,
A. E. C. Coimbra,
J. M. F. dos Santos,
J. A. M. Lopes,
C. D. R. Azevedo,
J. F. C. A. Veloso
Abstract:
The properties of UV-photon imaging detectors consisting of CsI-coated THGEM electron multipliers are summarized. New results related to detection of Cherenkov light (RICH) and scintillation photons in noble liquid are presented.
The properties of UV-photon imaging detectors consisting of CsI-coated THGEM electron multipliers are summarized. New results related to detection of Cherenkov light (RICH) and scintillation photons in noble liquid are presented.
△ Less
Submitted 29 September, 2010;
originally announced September 2010.