Machine Learning based tool for CMS RPC currents quality monitoring
Authors:
E. Shumka,
A. Samalan,
M. Tytgat,
M. El Sawy,
G. A. Alves,
F. Marujo,
E. A. Coelho,
E. M. Da Costa,
H. Nogima,
A. Santoro,
S. Fonseca De Souza,
D. De Jesus Damiao,
M. Thiel,
K. Mota Amarilo,
M. Barroso Ferreira Filho,
A. Aleksandrov,
R. Hadjiiska,
P. Iaydjiev,
M. Rodozov,
M. Shopova,
G. Soultanov,
A. Dimitrov,
L. Litov,
B. Pavlov,
P. Petkov
, et al. (83 additional authors not shown)
Abstract:
The muon system of the CERN Compact Muon Solenoid (CMS) experiment includes more than a thousand Resistive Plate Chambers (RPC). They are gaseous detectors operated in the hostile environment of the CMS underground cavern on the Large Hadron Collider where pp luminosities of up to $2\times 10^{34}$ $\text{cm}^{-2}\text{s}^{-1}$ are routinely achieved. The CMS RPC system performance is constantly m…
▽ More
The muon system of the CERN Compact Muon Solenoid (CMS) experiment includes more than a thousand Resistive Plate Chambers (RPC). They are gaseous detectors operated in the hostile environment of the CMS underground cavern on the Large Hadron Collider where pp luminosities of up to $2\times 10^{34}$ $\text{cm}^{-2}\text{s}^{-1}$ are routinely achieved. The CMS RPC system performance is constantly monitored and the detector is regularly maintained to ensure stable operation. The main monitorable characteristics are dark current, efficiency for muon detection, noise rate etc. Herein we describe an automated tool for CMS RPC current monitoring which uses Machine Learning techniques. We further elaborate on the dedicated generalized linear model proposed already and add autoencoder models for self-consistent predictions as well as hybrid models to allow for RPC current predictions in a distant future.
△ Less
Submitted 6 February, 2023;
originally announced February 2023.
-
RPC based tracking system at CERN GIF++ facility
Authors:
K. Mota Amarilo,
A. Samalan,
M. Tytgat,
M. El Sawy,
G. A. Alves,
F. Marujo,
E. A. Coelho,
E. M. Da Costa,
H. Nogima,
A. Santoro,
S. Fonseca De Souza,
D. De Jesus Damiao,
M. Thiel,
M. Barroso Ferreira Filho,
A. Aleksandrov,
R. Hadjiiska,
P. Iaydjiev,
M. Rodozov,
M. Shopova,
G. Soultanov,
A. Dimitrov,
L. Litov,
B. Pavlov,
P. Petkov,
A. Petrov
, et al. (83 additional authors not shown)
Abstract:
With the HL-LHC upgrade of the LHC machine, an increase of the instantaneous luminosity by a factor of five is expected and the current detection systems need to be validated for such working conditions to ensure stable data taking. At the CERN Gamma Irradiation Facility (GIF++) many muon detectors undergo such studies, but the high gamma background can pose a challenge to the muon trigger system…
▽ More
With the HL-LHC upgrade of the LHC machine, an increase of the instantaneous luminosity by a factor of five is expected and the current detection systems need to be validated for such working conditions to ensure stable data taking. At the CERN Gamma Irradiation Facility (GIF++) many muon detectors undergo such studies, but the high gamma background can pose a challenge to the muon trigger system which is exposed to many fake hits from the gamma background. A tracking system using RPCs is implemented to clean the fake hits, taking profit of the high muon efficiency of these chambers. This work will present the tracking system configuration, used detector analysis algorithm and results.
△ Less
Submitted 29 November, 2022;
originally announced November 2022.
-
Small-Signal Analysis of the Microgrid Secondary Control Considering a Communication Time Delay
Authors:
Ernane A. Alves Coelho,
Dan Wu,
Josep M. Guerrero,
Juan C. Vasquez,
Tomislav Dragicevic,
Cedomir Stefanovic,
Petar Popovski
Abstract:
This paper presents a small-signal analysis of an islanded microgrid composed of two or more voltage source inverters connected in parallel. The primary control of each inverter is integrated through internal current and voltage loops using PR compensators, a virtual impedance, and an external power controller based on frequency and voltage droops. The frequency restoration function is implemented…
▽ More
This paper presents a small-signal analysis of an islanded microgrid composed of two or more voltage source inverters connected in parallel. The primary control of each inverter is integrated through internal current and voltage loops using PR compensators, a virtual impedance, and an external power controller based on frequency and voltage droops. The frequency restoration function is implemented at the secondary control level, which executes a consensus algorithm that consists of a load-frequency control and a single time delay communication network. The consensus network consists of a time-invariant directed graph and the output power of each inverter is the information shared among the units, which is affected by the time delay. The proposed small-signal model is validated through simulation results and experimental results. A root locus analysis is presented that shows the behavior of the system considering control parameters and time delay variation.
△ Less
Submitted 5 July, 2017;
originally announced July 2017.
-
The Rate and Spatial Distribution of Novae in M101 (NGC 5457)
Authors:
E. A. Coelho,
A. W. Shafter,
K. A. Misselt
Abstract:
A new multi-epoch H-alpha imaging study of M101 (NGC 5457) has been carried out as part of a larger campaign to study the rate and stellar population of extragalactic novae. The survey yielded a total of 13 nova detections from 10 epochs of M101 observations spanning a three year period. After correcting for the temporal coverage and survey completeness, a global nova rate of 11.7^{+1.9}_{-1.5}…
▽ More
A new multi-epoch H-alpha imaging study of M101 (NGC 5457) has been carried out as part of a larger campaign to study the rate and stellar population of extragalactic novae. The survey yielded a total of 13 nova detections from 10 epochs of M101 observations spanning a three year period. After correcting for the temporal coverage and survey completeness, a global nova rate of 11.7^{+1.9}_{-1.5} per year is found. This value corresponds to a luminosity-specific nova rate of 1.23\pm0.27 novae per year per 10^{10} L_{\sun,K} when the K luminosity is derived from the B-K color, or 1.94\pm0.42 novae per year per 10^{10} L_{\sun,K} when the K magnitude from the Two Micron All Sky Survey is used. These values are consistent with previous estimates by Shafter et al. that were based on more limited data. The spatial distribution of the combined nova sample from the present survey and from the earlier Shafter et al. survey shows that the specific frequency of novae closely follows the integrated background light of the galaxy.
△ Less
Submitted 1 July, 2008;
originally announced July 2008.
-
Photometry of VS0329+1250: A New, Short-Period SU Ursae Majoris Star
Authors:
A. W. Shafter,
E. A. Coelho,
J. K. Reed
Abstract:
Time-resolved CCD photometry is presented of the recently-discovered (V~15 at maximum light) eruptive variable star in Taurus, which we dub VS0329+1250. A total of ~20 hr of data obtained over six nights reveals superhumps in the light curves, confirming the star as a member of the SU UMa class of dwarf novae. The superhumps recur with a mean period of 0.053394(7) days (76.89 min), which represe…
▽ More
Time-resolved CCD photometry is presented of the recently-discovered (V~15 at maximum light) eruptive variable star in Taurus, which we dub VS0329+1250. A total of ~20 hr of data obtained over six nights reveals superhumps in the light curves, confirming the star as a member of the SU UMa class of dwarf novae. The superhumps recur with a mean period of 0.053394(7) days (76.89 min), which represents the shortest superhump period known in a classical SU UMa star. A quadratic fit to the timings of superhump maxima reveals that the superhump period was increasing at a rate given by dP/dt ~ (2.1 +/- 0.8) x 10^{-5} over the course of our observations. An empirical relation between orbital period and the absolute visual magnitude of dwarf novae at maximum light, suggests that VS0329+1250 lies at a distance of ~1.2 +/- 0.2 kpc.
△ Less
Submitted 26 February, 2007; v1 submitted 5 February, 2007;
originally announced February 2007.