-
Three-sided pyramid wavefront sensor. II. Preliminary demonstration on the new CACTI testbed
Authors:
Lauren Schatz,
Johanan Codona,
Joseph D. Long,
Jared R. Males,
Weslin Pullen,
Jennifer Lumbres,
Kyle Van Gorkom,
Vincent Chambouleyron,
Laird M. Close,
Carlos Correia,
Olivier Fauvarque,
Thierry Fusco,
Olivier Guyon,
Michael Hart,
Pierre Janin-Potiron,
Robert Johnson,
Nemanja Jovanovic,
Mala Mateen,
Jean-Francois Sauvage,
Benoit Neichel
Abstract:
The next generation of giant ground and space telescopes will have the light-collecting power to detect and characterize potentially habitable terrestrial exoplanets using high-contrast imaging for the first time. This will only be achievable if the performance of Giant Segmented Mirror Telescopes (GSMTs) extreme adaptive optics (ExAO) systems are optimized to their full potential. A key component…
▽ More
The next generation of giant ground and space telescopes will have the light-collecting power to detect and characterize potentially habitable terrestrial exoplanets using high-contrast imaging for the first time. This will only be achievable if the performance of Giant Segmented Mirror Telescopes (GSMTs) extreme adaptive optics (ExAO) systems are optimized to their full potential. A key component of an ExAO system is the wavefront sensor (WFS), which measures aberrations from atmospheric turbulence. A common choice in current and next-generation instruments is the pyramid wavefront sensor (PWFS). ExAO systems require high spatial and temporal sampling of wavefronts to optimize performance, and as a result, require large detectors for the WFS. We present a closed-loop testbed demonstration of a three-sided pyramid wavefront sensor (3PWFS) as an alternative to the conventional four-sided pyramid wavefront (4PWFS) sensor for GSMT-ExAO applications on the new Comprehensive Adaptive Optics and Coronagraph Test Instrument (CACTI). The 3PWFS is less sensitive to read noise than the 4PWFS because it uses fewer detector pixels. The 3PWFS has further benefits: a high-quality three-sided pyramid optic is easier to manufacture than a four-sided pyramid. We detail the design of the two components of the CACTI system, the adaptive optics simulator and the PWFS testbed that includes both a 3PWFS and 4PWFS. A preliminary experiment was performed on CACTI to study the performance of the 3PWFS to the 4PWFS in varying strengths of turbulence using both the Raw Intensity and Slopes Map signal processing methods. This experiment was repeated for a modulation radius of 1.6 lambda/D and 3.25 lambda/D. We found that the performance of the two wavefront sensors is comparable if modal loop gains are tuned.
△ Less
Submitted 7 October, 2022;
originally announced October 2022.
-
The Three-Sided PyramidWavefront Sensor. I. Simulations and Analysis for Astronomical Adaptive Optics
Authors:
Lauren Schatz,
Jared R. Males,
Carlos Correia,
Benoit Neichel,
Vincent Chambouleyron,
Johanan Codona,
Olivier Fauvarque,
Jean-François Sauvage,
Thierry Fusco,
Michael Hart,
Pierre Janin-Potiron,
Robert Johnson,
Joseph Long,
Mala Mateen
Abstract:
For ExAO instruments for the Giant Segmented Mirror Telescopes (GSMTs), alternative architectures of WFS are under consideration because there is a tradeoff between detector size, speed, and noise that reduces the performance of GSMT-ExAO wavefront control. One option under consideration for a GSMT-ExAO wavefront sensor is a three-sided PWFS (3PWFS). The 3PWFS creates three copies of the telescope…
▽ More
For ExAO instruments for the Giant Segmented Mirror Telescopes (GSMTs), alternative architectures of WFS are under consideration because there is a tradeoff between detector size, speed, and noise that reduces the performance of GSMT-ExAO wavefront control. One option under consideration for a GSMT-ExAO wavefront sensor is a three-sided PWFS (3PWFS). The 3PWFS creates three copies of the telescope pupil for wavefront sensing, compared to the conventional four-sided PWFS (4PWFS) which uses four pupils. The 3PWFS uses fewer detector pixels than the 4PWFS and should therefore be less sensitive to read noise. Here we develop a mathematical formalism based on the diffraction theory description of the Foucault knife edge test that predicts the intensity pattern after the PWFS. Our formalism allows us to calculate the intensity in the pupil images formed by the PWFS in the presence of phase errors corresponding to arbitrary Fourier modes. We then use the Object Oriented MATLAB Adaptive Optics toolbox (OOMAO) to simulate an end-to-end model of an adaptive optics system using a PWFS with modulation and compare the performance of the 3PWFS to the 4PWFS. In the case of a low read noise detector, the Strehl ratios of the 3PWFS and 4PWFS are within 0.01. When we included higher read noise in the simulation, we found a Strehl ratio gain of 0.036 for the 3PWFS using Raw Intensity over the 4PWFS using Slopes Maps at a stellar magnitude of 10. At the same magnitude, the 4PWFS RI also outperformed the 4PWFS SM, but the gain was only 0.012 Strehl. This is significant because 4PWFS using Slopes Maps is how the PWFS is conventionally used for AO wavefront sensing. We have found that the 3PWFS is a viable wavefront sensor that can fully reconstruct a wavefront and produce a stable closed-loop with correction comparable to that of a 4PWFS, with modestly better performance for high read-noise detectors.
△ Less
Submitted 13 September, 2021;
originally announced September 2021.
-
The vector-apodizing phase plate coronagraph: design, current performance, and future development
Authors:
D. S. Doelman,
F. Snik,
E. H. Por,
S. P. Bos,
G. P. P. L. Otten,
M. Kenworthy,
S. Y. Haffert,
M. Wilby,
A. J. Bohn,
B. J. Sutlieff,
K. Miller,
M. Ouellet,
J. de Boer,
C. U. Keller,
M. J. Escuti,
S. Shi,
N. Z. Warriner,
K. J. Hornburg,
J. L. Birkby,
J. Males,
K. M. Morzinski,
L. M. Close,
J. Codona,
J. Long,
L. Schatz
, et al. (28 additional authors not shown)
Abstract:
Over the last decade, the vector-apodizing phase plate (vAPP) coronagraph has been developed from concept to on-sky application in many high-contrast imaging systems on 8-m class telescopes. The vAPP is an geometric-phase patterned coronagraph that is inherently broadband, and its manufacturing is enabled only by direct-write technology for liquid-crystal patterns. The vAPP generates two coronagra…
▽ More
Over the last decade, the vector-apodizing phase plate (vAPP) coronagraph has been developed from concept to on-sky application in many high-contrast imaging systems on 8-m class telescopes. The vAPP is an geometric-phase patterned coronagraph that is inherently broadband, and its manufacturing is enabled only by direct-write technology for liquid-crystal patterns. The vAPP generates two coronagraphic PSFs that cancel starlight on opposite sides of the point spread function (PSF) and have opposite circular polarization states. The efficiency, that is the amount of light in these PSFs, depends on the retardance offset from half-wave of the liquid-crystal retarder. Using different liquid-crystal recipes to tune the retardance, different vAPPs operate with high efficiencies ($>96\%$) in the visible and thermal infrared (0.55 $μ$m to 5 $μ$m). Since 2015, seven vAPPs have been installed in a total of six different instruments, including Magellan/MagAO, Magellan/MagAO-X, Subaru/SCExAO, and LBT/LMIRcam. Using two integral field spectrographs installed on the latter two instruments, these vAPPs can provide low-resolution spectra (R$\sim$30) between 1 $μ$m and 5 $μ$m. We review the design process, development, commissioning, on-sky performance, and first scientific results of all commissioned vAPPs. We report on the lessons learned and conclude with perspectives for future developments and applications.
△ Less
Submitted 4 November, 2021; v1 submitted 22 April, 2021;
originally announced April 2021.
-
Pupil Plane Phase Apodization
Authors:
Matthew A. Kenworthy,
Johanan L. Codona,
Frans Snik
Abstract:
Phase apodization coronagraphs are implemented in a pupil plane to create a dark hole in the science camera focal plane. They are successfully created as "Apodizing Phase Plates" (APPs) using classical optical manufacturing, and as "vector-APPs" using liquid-crystal patterning with essentially achromatic performance. This type of coronagraph currently delivers excellent broadband contrast ($\sim$1…
▽ More
Phase apodization coronagraphs are implemented in a pupil plane to create a dark hole in the science camera focal plane. They are successfully created as "Apodizing Phase Plates" (APPs) using classical optical manufacturing, and as "vector-APPs" using liquid-crystal patterning with essentially achromatic performance. This type of coronagraph currently delivers excellent broadband contrast ($\sim$10$^{-5}$) at small angular separations (few $λ/D$) at ground-based telescopes, owing to their insensitivity to tip/tilt errors.
△ Less
Submitted 30 July, 2018;
originally announced July 2018.
-
On-sky performance analysis of the vector Apodizing Phase Plate coronagraph on MagAO/Clio2
Authors:
Gilles P. P. L. Otten,
Frans Snik,
Matthew A. Kenworthy,
Christoph U. Keller,
Jared R. Males,
Katie M. Morzinski,
Laird M. Close,
Johanan L. Codona,
Philip M. Hinz,
Kathryn J. Hornburg,
Leandra L. Brickson,
Michael J. Escuti
Abstract:
We report on the performance of a vector apodizing phase plate coronagraph that operates over a wavelength range of $2-5 μ$m and is installed in MagAO/Clio2 at the 6.5 m Magellan Clay telescope at Las Campanas Observatory, Chile. The coronagraph manipulates the phase in the pupil to produce three beams yielding two coronagraphic point-spread functions (PSFs) and one faint leakage PSF. The phase pa…
▽ More
We report on the performance of a vector apodizing phase plate coronagraph that operates over a wavelength range of $2-5 μ$m and is installed in MagAO/Clio2 at the 6.5 m Magellan Clay telescope at Las Campanas Observatory, Chile. The coronagraph manipulates the phase in the pupil to produce three beams yielding two coronagraphic point-spread functions (PSFs) and one faint leakage PSF. The phase pattern is imposed through the inherently achromatic geometric phase, enabled by liquid crystal technology and polarization techniques. The coronagraphic optic is manufactured using a direct-write technique for precise control of the liquid crystal pattern, and multitwist retarders for achromatization. By integrating a linear phase ramp to the coronagraphic phase pattern, two separated coronagraphic PSFs are created with a single pupil-plane optic, which makes it robust and easy to install in existing telescopes. The two coronagraphic PSFs contain a 180$^\circ$ dark hole on each side of a star, and these complementary copies of the star are used to correct the seeing halo close to the star. To characterize the coronagraph, we collected a dataset of a bright ($m_L=0-1$) nearby star with $\sim$1.5 hr of observing time. By rotating and optimally scaling one PSF and subtracting it from the other PSF, we see a contrast improvement by 1.46 magnitudes at $3.5 λ/D$. With regular angular differential imaging at 3.9 $μ$m, the MagAO vector apodizing phase plate coronagraph delivers a $5σ Δ$ mag contrast of 8.3 ($=10^{-3.3}$) at 2 $λ/D$ and 12.2 ($=10^{-4.8}$) at $3.5 λ/D$.
△ Less
Submitted 14 February, 2017;
originally announced February 2017.
-
Polarization dOTF: on-sky focal plane wavefront sensing
Authors:
Keira J. Brooks,
Laure Catala,
Matthew A. Kenworthy,
Steven M. Crawford,
Johanan L. Codona
Abstract:
The differential Optical Transfer Function (dOTF) is a focal plane wavefront sensing method that uses a diversity in the pupil plane to generate two different focal plane images. The difference of their Fourier transforms recovers the complex amplitude of the pupil down to the spatial scale of the diversity. We produce two simultaneous PSF images with diversity using a polarizing filter at the edg…
▽ More
The differential Optical Transfer Function (dOTF) is a focal plane wavefront sensing method that uses a diversity in the pupil plane to generate two different focal plane images. The difference of their Fourier transforms recovers the complex amplitude of the pupil down to the spatial scale of the diversity. We produce two simultaneous PSF images with diversity using a polarizing filter at the edge of the telescope pupil, and a polarization camera to simultaneously record the two images. Here we present the first on-sky demonstration of polarization dOTF at the 1.0m South African Astronomical Observatory telescope in Sutherland, and our attempt to validate it with simultaneous Shack-Hartmann wavefront sensor images.
△ Less
Submitted 16 August, 2016;
originally announced August 2016.
-
James Webb Space Telescope segment phasing using differential optical transfer functions
Authors:
Johanan L. Codona,
Nathan Doble
Abstract:
Differential Optical Transfer Function (dOTF) is an image-based, non-iterative wavefront sensing method that uses two star images with a single small change in the pupil. We describe two possible methods for introducing the required pupil modification to the JWST, one using a small (<lambda/4) displacement of a single segment's actuator and another that uses small misalignments of NIRCam's filter…
▽ More
Differential Optical Transfer Function (dOTF) is an image-based, non-iterative wavefront sensing method that uses two star images with a single small change in the pupil. We describe two possible methods for introducing the required pupil modification to the JWST, one using a small (<lambda/4) displacement of a single segment's actuator and another that uses small misalignments of NIRCam's filter wheel. While both methods should work with NIRCam, the actuator method will allow both MIRI and NIRISS to be used for segment phasing, which is new functionality. Since the actuator method requires only small displacements, it should provide a fast and safe phasing alternative that reduces mission risk and can be performed frequently for alignment monitoring and maintenance. Since a single actuator modification can be seen by all three cameras, it should be possible to calibrate the non-common-path aberrations between them. Large segment discontinuities can be measured using dOTFs in two filter bands. Using two images of a star field, aberrations along multiple lines of sight through the telescope can be measured simultaneously. Also, since dOTF gives the pupil field amplitude as well as phase, it could provide a first approximation or constraint to the planned iterative phase retrieval algorithms.
△ Less
Submitted 27 February, 2015;
originally announced February 2015.
-
Calibrating a high-resolution wavefront corrector with a static focal-plane camera
Authors:
Visa Korkiakoski,
Niek Doelman,
Johanan Codona,
Matthew Kenworthy,
Gilles Otten,
Christoph U. Keller
Abstract:
We present a method to calibrate a high-resolution wavefront-correcting device with a single, static camera, located in the focal plane; no moving of any component is needed. The method is based on a localized diversity and differential optical transfer functions (dOTF) to compute both the phase and amplitude in the pupil plane located upstream of the last imaging optics. An experiment with a spat…
▽ More
We present a method to calibrate a high-resolution wavefront-correcting device with a single, static camera, located in the focal plane; no moving of any component is needed. The method is based on a localized diversity and differential optical transfer functions (dOTF) to compute both the phase and amplitude in the pupil plane located upstream of the last imaging optics. An experiment with a spatial light modulator shows that the calibration is sufficient to robustly operate a focal-plane wavefront sensing algorithm controlling a wavefront corrector with ~40 000 degrees of freedom. We estimate that the locations of identical wavefront corrector elements are determined with a spatial resolution of 0.3% compared to the pupil diameter.
△ Less
Submitted 3 October, 2013;
originally announced October 2013.
-
Differential OTF Wavefront Sensing
Authors:
Johanan L. Codona
Abstract:
An image-based technique for measuring the complex field in the pupil of an imaging system is presented. Two point source images, one with a small modification introduced in the pupil, are combined using a simple and non-iterative algorithm. The non-interferometric method is based on the change in the optical transfer function (OTF), giving a differential OTF (dOTF). The dOTF includes two images o…
▽ More
An image-based technique for measuring the complex field in the pupil of an imaging system is presented. Two point source images, one with a small modification introduced in the pupil, are combined using a simple and non-iterative algorithm. The non-interferometric method is based on the change in the optical transfer function (OTF), giving a differential OTF (dOTF). The dOTF includes two images of the complex pupil field, conjugated and reflected about the position of the pupil modification, leaving an overlap that obscures some the the pupil. The overlap can be minimized by introducing the modification near the edge of the pupil. The overlap region can be eliminated altogether by using a second modification and a third point source image. The pupil field is convolved by the change in the pupil field, so smaller modification areas are preferred. The non-monochromatic light, but the result incurs a proportional radial blurring determined by the fractional bandwidth. We include some simple demonstration experiments, including using a pupil blockage and moving a single deformable mirror actuator as the pupil modification. In each case the complex wavefront is easily recovered, even when the pupil mask is unknown and the wavefront aberrations are large.
△ Less
Submitted 26 September, 2013;
originally announced September 2013.
-
Focal Plane Wavefront Sensing using Residual Adaptive Optics Speckles
Authors:
Johanan L. Codona,
Matthew Kenworthy
Abstract:
Optical imperfections, misalignments, aberrations, and even dust can significantly limit sensitivity in high-contrast imaging systems such as coronagraphs. An upstream deformable mirror (DM) in the pupil can be used to correct or compensate for these flaws, either to enhance Strehl ratio or suppress residual coronagraphic halo. Measurement of the phase and amplitude of the starlight halo at the sc…
▽ More
Optical imperfections, misalignments, aberrations, and even dust can significantly limit sensitivity in high-contrast imaging systems such as coronagraphs. An upstream deformable mirror (DM) in the pupil can be used to correct or compensate for these flaws, either to enhance Strehl ratio or suppress residual coronagraphic halo. Measurement of the phase and amplitude of the starlight halo at the science camera is essential for determining the DM shape that compensates for any non-common-path (NCP) wavefront errors. Using DM displacement ripples to create a series of probe and anti-halo speckles in the focal plane has been proposed for space-based coronagraphs and successfully demonstrated in the lab. We present the theory and first on-sky demonstration of a technique to measure the complex halo using the rapidly-changing residual atmospheric speckles at the 6.5m MMT telescope using the Clio mid-IR camera. The AO system's wavefront sensor (WFS) measurements are used to estimate the residual wavefront, allowing us to approximately compute the rapidly-evolving phase and amplitude of speckle halo. When combined with relatively-short, synchronized science camera images, the complex speckle estimates can be used to interferometrically analyze the images, leading to an estimate of the static diffraction halo with NCP effects included. In an operational system, this information could be collected continuously and used to iteratively correct quasi-static NCP errors or suppress imperfect coronagraphic halos.
△ Less
Submitted 3 March, 2013;
originally announced March 2013.
-
The Vector-APP: a Broadband Apodizing Phase Plate that yields Complementary PSFs
Authors:
Frans Snik,
Gilles Otten,
Matthew Kenworthy,
Matthew Miskiewicz,
Michael Escuti,
Christopher Packham,
Johanan Codona
Abstract:
The apodizing phase plate (APP) is a solid-state pupil optic that clears out a D-shaped area next to the core of the ensuing PSF. To make the APP more efficient for high-contrast imaging, its bandwidth should be as large as possible, and the location of the D-shaped area should be easily swapped to the other side of the PSF. We present the design of a broadband APP that yields two PSFs that have t…
▽ More
The apodizing phase plate (APP) is a solid-state pupil optic that clears out a D-shaped area next to the core of the ensuing PSF. To make the APP more efficient for high-contrast imaging, its bandwidth should be as large as possible, and the location of the D-shaped area should be easily swapped to the other side of the PSF. We present the design of a broadband APP that yields two PSFs that have the opposite sides cleared out. Both properties are enabled by a half-wave liquid crystal layer, for which the local fast axis orientation over the pupil is forced to follow the required phase structure. For each of the two circular polarization states, the required phase apodization is thus obtained, and, moreover, the PSFs after a quarter-wave plate and a polarizing beam-splitter are complementary due to the antisymmetric nature of the phase apodization. The device can be achromatized in the same way as half-wave plates of the Pancharatnam type or by layering self-aligning twisted liquid crystals to form a monolithic film called a multi-twist retarder. As the VAPP introduces a known phase diversity between the two PSFs, they may be used directly for wavefront sensing. By applying an additional quarter-wave plate in front, the device also acts as a regular polarizing beam-splitter, which therefore furnishes high-contrast polarimetric imaging. If the PSF core is not saturated, the polarimetric dual-beam correction can also be applied to polarized circumstellar structure. The prototype results show the viability of the vector-APP concept.
△ Less
Submitted 12 July, 2012;
originally announced July 2012.
-
An apodizing phase plate coronagraph for VLT/NACO
Authors:
Matthew A. Kenworthy,
Sascha P. Quanz,
Michael R. Meyer,
Markus E. Kasper,
Rainer Lenzen,
Johanan L. Codona,
Julien H. V. Girard,
Philip M. Hinz
Abstract:
We describe a coronagraphic optic for use with CONICA at the VLT that provides suppression of diffraction from 1.8 to 7 lambda/D at 4.05 microns, an optimal wavelength for direct imaging of cool extrasolar planets. The optic is designed to provide 10 magnitudes of contrast at 0.2 arcseconds, over a D-shaped region in the image plane, without the need for any focal plane occulting mask.
We describe a coronagraphic optic for use with CONICA at the VLT that provides suppression of diffraction from 1.8 to 7 lambda/D at 4.05 microns, an optimal wavelength for direct imaging of cool extrasolar planets. The optic is designed to provide 10 magnitudes of contrast at 0.2 arcseconds, over a D-shaped region in the image plane, without the need for any focal plane occulting mask.
△ Less
Submitted 20 July, 2010;
originally announced July 2010.
-
First On-Sky High Contrast Imaging with an Apodizing Phase Plate
Authors:
Matthew A. Kenworthy,
Johanan L. Codona,
Philip M. Hinz,
J. Roger P. Angel,
Ari Heinze,
Suresh Sivanandam
Abstract:
We present the first astronomical observations obtained with an Apodizing Phase Plate (APP). The plate is designed to suppress the stellar diffraction pattern by 5 magnitudes from 2-9 lambda/D over a 180 degree region. Stellar images were obtained in the M' band (4.85 microns) at the MMTO 6.5m telescope, with adaptive wavefront correction made with a deformable secondary mirror designed for low…
▽ More
We present the first astronomical observations obtained with an Apodizing Phase Plate (APP). The plate is designed to suppress the stellar diffraction pattern by 5 magnitudes from 2-9 lambda/D over a 180 degree region. Stellar images were obtained in the M' band (4.85 microns) at the MMTO 6.5m telescope, with adaptive wavefront correction made with a deformable secondary mirror designed for low thermal background observations. The measured PSF shows a halo intensity of 0.1% of the stellar peak at 2 lambda/D (0.36 arcsec), tapering off as r^{-5/3} out to radius 9 lambda/D. Such a profile is consistent with residual errors predicted for servo lag in the AO system.
We project a 5 sigma contrast limit, set by residual atmospheric fluctuations, of 10.2 magnitudes at 0.36 arcsec separation for a one hour exposure. This can be realised if static and quasi-static aberrations are removed by differential imaging, and is close to the sensitivity level set by thermal background photon noise for target stars with M'>3. The advantage of using the phase plate is the removal of speckle noise caused by the residuals in the diffraction pattern that remain after PSF subtraction. The APP gives higher sensitivity over the range 2-5 lambda/D compared to direct imaging techniques.
△ Less
Submitted 12 February, 2007;
originally announced February 2007.
-
Telescope to Observe Planetary Systems (TOPS): a high throughput 1.2-m visible telescope with a small inner working angle
Authors:
Olivier Guyon,
James R. P. Angel,
Charles Bowers,
James Burge,
Adam Burrows,
Johanan Codona,
Thomas Greene,
Masanori Iye,
James Kasting,
Hubert Martin,
Donald W. McCarthy, Jr.,
Victoria Meadows,
Michael Meyer,
Eugene A. Pluzhnik,
Norman Sleep,
Tony Spears,
Motohide Tamura,
Domenick Tenerelli,
Robert Vanderbei,
Bruce Woodgate,
Robert A. Woodruff,
Neville J. Woolf,
/
Abstract:
The Telescope to Observe Planetary Systems (TOPS) is a proposed space mission to image in the visible (0.4-0.9 micron) planetary systems of nearby stars simultaneously in 16 spectral bands (resolution R~20). For the ~10 most favorable stars, it will have the sensitivity to discover 2 R_E rocky planets within habitable zones and characterize their surfaces or atmospheres through spectrophotometry…
▽ More
The Telescope to Observe Planetary Systems (TOPS) is a proposed space mission to image in the visible (0.4-0.9 micron) planetary systems of nearby stars simultaneously in 16 spectral bands (resolution R~20). For the ~10 most favorable stars, it will have the sensitivity to discover 2 R_E rocky planets within habitable zones and characterize their surfaces or atmospheres through spectrophotometry. Many more massive planets and debris discs will be imaged and characterized for the first time. With a 1.2m visible telescope, the proposed mission achieves its power by exploiting the most efficient and robust coronagraphic and wavefront control techniques. The Phase-Induced Amplitude Apodization (PIAA) coronagraph used by TOPS allows planet detection at 2 lambda/d with nearly 100% throughput and preserves the telescope angular resolution. An efficient focal plane wavefront sensing scheme accurately measures wavefront aberrations which are fed back to the telescope active primary mirror. Fine wavefront control is also performed independently in each of 4 spectral channels, resulting in a system that is robust to wavefront chromaticity.
△ Less
Submitted 15 June, 2006;
originally announced June 2006.
-
Imaging extrasolar planets by stellar halo suppression in separately-corrected color bands
Authors:
Johanan L. Codona,
Roger Angel
Abstract:
Extra-solar planets have not been imaged directly with existing ground or space telescopes because they are too faint to be seen against the halo of the nearby bright star. Most techniques being explored to suppress the halo are achromatic, with separate correction of diffraction and wavefront errors. Residual speckle structure may be subtracted by differencing images taken through narrowband fi…
▽ More
Extra-solar planets have not been imaged directly with existing ground or space telescopes because they are too faint to be seen against the halo of the nearby bright star. Most techniques being explored to suppress the halo are achromatic, with separate correction of diffraction and wavefront errors. Residual speckle structure may be subtracted by differencing images taken through narrowband filters, but photon noise remains and ultimately limits sensitivity. Here we describe two ways to take advantage of narrow bands to reduce speckle photon flux and to obtain better control of systematic errors. Multiple images are formed in separate color bands of 5-10% bandwidth, and recorded by coronagraphic interferometers equipped with active control of wavefront phase and/or amplitude. In one method, a single deformable pupil mirror is used to actively correct both diffraction and wavefront components of the halo. This yields good diffraction suppression for complex pupil obscuration, with high throughput over half the focal plane. In a second method, the coronagraphic interferometer is used as a second stage after conventional apodization. The halo from uncontrollable residual errors in the pupil mask or wavefront is removed by destructive interference made directly at the detector focal plane with an "anti-halo", synthesized by spatial light modulators in the reference arm of the interferometer. In this way very deep suppression may be achieved by control elements with greatly relaxed, and thus achievable, tolerances. In both examples, systematic errors are minimized because the planet imaging cameras themselves also provide the error sensing data.
△ Less
Submitted 17 February, 2004;
originally announced February 2004.