-
In-silico analysis of the influence of pulmonary vein configuration on left atrial haemodynamics and thrombus formation in a large cohort
Authors:
Jordi Mill,
Josquin Harrison,
Benoit Legghe,
Andy L. Olivares,
Xabier Morales,
Jerome Noailly,
Xavier Iriart,
Hubert Cochet,
Maxime Sermesant,
Oscar Camara
Abstract:
Atrial fibrillation (AF) is considered the most common human arrhythmia. Around 99\% of thrombi in non-valvular AF are formed in the left atrial appendage (LAA). Studies suggest that abnormal LAA haemodynamics and the subsequently stagnated flow are the factors triggering clot formation. However, the relation between LAA morphology, the blood pattern and the triggering is not fully understood. Mor…
▽ More
Atrial fibrillation (AF) is considered the most common human arrhythmia. Around 99\% of thrombi in non-valvular AF are formed in the left atrial appendage (LAA). Studies suggest that abnormal LAA haemodynamics and the subsequently stagnated flow are the factors triggering clot formation. However, the relation between LAA morphology, the blood pattern and the triggering is not fully understood. Moreover, the impact of structures such as the pulmonary veins (PVs) on LA haemodynamics has not been thoroughly studied due to the difficulties of acquiring appropriate data. On the other hand, in-silico studies and flow simulations allow a thorough analysis of haemodynamics, analysing the 4D nature of blood flow patterns under different boundary conditions. However, the reduced number of cases reported on the literature of these studies has been a limitation. The main goal of this work was to study the influence of PVs on left atrium (LA) and LAA haemodynamics. Computational fluid dynamics simulations were run on 52 patients, the largest cohort so far in the literature, where different parameters were individually studied: pulmonary veins orientation and configuration; LAA and LA volumes and its ratio; and flow velocities. Our computational analysis showed how the right pulmonary vein height and angulation have a great influence on LA haemodynamics. Additionally, we found that LAA with great bending with its tip pointing towards the mitral valve could contribute to favour flow stagnation.
△ Less
Submitted 19 October, 2022;
originally announced October 2022.
-
Automatically Segmenting the Left Atrium from Cardiac Images Using Successive 3D U-Nets and a Contour Loss
Authors:
Shuman Jia,
Antoine Despinasse,
Zihao Wang,
Hervé Delingette,
Xavier Pennec,
Pierre Jaïs,
Hubert Cochet,
Maxime Sermesant
Abstract:
Radiological imaging offers effective measurement of anatomy, which is useful in disease diagnosis and assessment. Previous study has shown that the left atrial wall remodeling can provide information to predict treatment outcome in atrial fibrillation. Nevertheless, the segmentation of the left atrial structures from medical images is still very time-consuming. Current advances in neural network…
▽ More
Radiological imaging offers effective measurement of anatomy, which is useful in disease diagnosis and assessment. Previous study has shown that the left atrial wall remodeling can provide information to predict treatment outcome in atrial fibrillation. Nevertheless, the segmentation of the left atrial structures from medical images is still very time-consuming. Current advances in neural network may help creating automatic segmentation models that reduce the workload for clinicians. In this preliminary study, we propose automated, two-stage, three-dimensional U-Nets with convolutional neural network, for the challenging task of left atrial segmentation. Unlike previous two-dimensional image segmentation methods, we use 3D U-Nets to obtain the heart cavity directly in 3D. The dual 3D U-Net structure consists of, a first U-Net to coarsely segment and locate the left atrium, and a second U-Net to accurately segment the left atrium under higher resolution. In addition, we introduce a Contour loss based on additional distance information to adjust the final segmentation. We randomly split the data into training datasets (80 subjects) and validation datasets (20 subjects) to train multiple models, with different augmentation setting. Experiments show that the average Dice coefficients for validation datasets are around 0.91 - 0.92, the sensitivity around 0.90-0.94 and the specificity 0.99. Compared with traditional Dice loss, models trained with Contour loss in general offer smaller Hausdorff distance with similar Dice coefficient, and have less connected components in predictions. Finally, we integrate several trained models in an ensemble prediction to segment testing datasets.
△ Less
Submitted 6 December, 2018;
originally announced December 2018.
-
Universal atrial coordinates applied to visualisation, registration and construction of patient specific meshes
Authors:
Caroline H Roney,
Ali Pashaei,
Marianna Meo,
Remi Dubois,
Patrick M Boyle,
Natalia A Trayanova,
Hubert Cochet,
Steven A Niederer,
Edward J Vigmond
Abstract:
Integrating spatial information about atrial physiology and anatomy in a single patient from multimodal datasets, as well as generalizing these data across patients, requires a common coordinate system. In the atria, this is challenging due to the complexity and variability of the anatomy. We aimed to develop and validate a universal atrial coordinate system for the following applications: combina…
▽ More
Integrating spatial information about atrial physiology and anatomy in a single patient from multimodal datasets, as well as generalizing these data across patients, requires a common coordinate system. In the atria, this is challenging due to the complexity and variability of the anatomy. We aimed to develop and validate a universal atrial coordinate system for the following applications: combination and assessment of multimodal data; comparison of spatial data across patients; 2D visualization; and construction of patient specific geometries to test mechanistic hypotheses. Left and right atrial LGE-MRI data were segmented and meshed. Two coordinates were calculated for each atrium by solving Laplace's equation, with boundary conditions assigned using five landmark points. The coordinate system was used to map spatial information between atrial meshes, including atrial anatomic structures and fibre directions from a reference geometry. Average error in point transfer from a source mesh to a destination mesh and back again was less than 6% of the average mesh element edge length. Scalar map** from electroanatomic to MRI geometries was compared to an affine registration technique (mean difference in bipolar voltage: <10% of voltage range). Patient specific meshes were constructed using UACs and phase singularity density maps from arrhythmia simulations were visualised in 2D. We have developed a universal atrial coordinate system allowing automatic registration of imaging and electroanatomic map** data, 2D visualisation, and patient specific model creation, using just five landmark points.
△ Less
Submitted 15 October, 2018;
originally announced October 2018.