-
Examining the Effect of Implementation Factors on Deep Learning Reproducibility
Authors:
Kevin Coakley,
Christine R. Kirkpatrick,
Odd Erik Gundersen
Abstract:
Reproducing published deep learning papers to validate their conclusions can be difficult due to sources of irreproducibility. We investigate the impact that implementation factors have on the results and how they affect reproducibility of deep learning studies. Three deep learning experiments were ran five times each on 13 different hardware environments and four different software environments.…
▽ More
Reproducing published deep learning papers to validate their conclusions can be difficult due to sources of irreproducibility. We investigate the impact that implementation factors have on the results and how they affect reproducibility of deep learning studies. Three deep learning experiments were ran five times each on 13 different hardware environments and four different software environments. The analysis of the 780 combined results showed that there was a greater than 6% accuracy range on the same deterministic examples introduced from hardware or software environment variations alone. To account for these implementation factors, researchers should run their experiments multiple times in different hardware and software environments to verify their conclusions are not affected.
△ Less
Submitted 11 December, 2023;
originally announced December 2023.
-
Engaging with Researchers and Raising Awareness of FAIR and Open Science through the FAIR+ Implementation Survey Tool (FAIRIST)
Authors:
Christine R. Kirkpatrick,
Kevin L. Coakley,
Julie Christopher,
Ines Dutra
Abstract:
Six years after the seminal paper on FAIR was published, researchers still struggle to understand how to implement FAIR. For many researchers FAIR promises long-term benefits for near-term effort, requires skills not yet acquired, and is one more thing in a long list of unfunded mandates and onerous requirements on scientists. Even for those required to or who are convinced they must make time for…
▽ More
Six years after the seminal paper on FAIR was published, researchers still struggle to understand how to implement FAIR. For many researchers FAIR promises long-term benefits for near-term effort, requires skills not yet acquired, and is one more thing in a long list of unfunded mandates and onerous requirements on scientists. Even for those required to or who are convinced they must make time for FAIR research practices, the preference is for just-in-time advice properly sized to the scientific artifacts and process. Because of the generality of most FAIR implementation guidance, it is difficult for a researcher to adjust the advice to their situation. Technological advances, especially in the area of artificial intelligence (AI) and machine learning (ML), complicate FAIR adoption as researchers and data stewards ponder how to make software, workflows, and models FAIR and reproducible. The FAIR+ Implementation Survey Tool (FAIRIST) mitigates the problem by integrating research requirements with research proposals in a systematic way. FAIRIST factors in new scholarly outputs such as nanopublications and notebooks, and the various research artifacts related to AI research (data, models, workflows, and benchmarks). Researchers step through a self-serve survey process and receive a table ready for use in their DMP and/or work plan while gaining awareness of the FAIR Principles and Open Science concepts. FAIRIST is a model that uses part of the proposal process as a way to do outreach, raise awareness of FAIR dimensions and considerations, while providing just-in-time assistance for competitive proposals.
△ Less
Submitted 17 January, 2023;
originally announced January 2023.
-
Sources of Irreproducibility in Machine Learning: A Review
Authors:
Odd Erik Gundersen,
Kevin Coakley,
Christine Kirkpatrick,
Yolanda Gil
Abstract:
Background: Many published machine learning studies are irreproducible. Issues with methodology and not properly accounting for variation introduced by the algorithm themselves or their implementations are attributed as the main contributors to the irreproducibility.Problem: There exist no theoretical framework that relates experiment design choices to potential effects on the conclusions. Without…
▽ More
Background: Many published machine learning studies are irreproducible. Issues with methodology and not properly accounting for variation introduced by the algorithm themselves or their implementations are attributed as the main contributors to the irreproducibility.Problem: There exist no theoretical framework that relates experiment design choices to potential effects on the conclusions. Without such a framework, it is much harder for practitioners and researchers to evaluate experiment results and describe the limitations of experiments. The lack of such a framework also makes it harder for independent researchers to systematically attribute the causes of failed reproducibility experiments. Objective: The objective of this paper is to develop a framework that enable applied data science practitioners and researchers to understand which experiment design choices can lead to false findings and how and by this help in analyzing the conclusions of reproducibility experiments. Method: We have compiled an extensive list of factors reported in the literature that can lead to machine learning studies being irreproducible. These factors are organized and categorized in a reproducibility framework motivated by the stages of the scientific method. The factors are analyzed for how they can affect the conclusions drawn from experiments. A model comparison study is used as an example. Conclusion: We provide a framework that describes machine learning methodology from experimental design decisions to the conclusions inferred from them.
△ Less
Submitted 14 April, 2023; v1 submitted 15 April, 2022;
originally announced April 2022.
-
Performance of Test Supermartingale Confidence Intervals for the Success Probability of Bernoulli Trials
Authors:
Peter Wills,
Emanuel Knill,
Kevin Coakley,
Yanbao Zhang
Abstract:
Given a composite null hypothesis H, test supermartingales are non-negative supermartingales with respect to H with initial value 1. Large values of test supermartingales provide evidence against H. As a result, test supermartingales are an effective tool for rejecting H, particularly when the p-values obtained are very small and serve as certificates against the null hypothesis. Examples include…
▽ More
Given a composite null hypothesis H, test supermartingales are non-negative supermartingales with respect to H with initial value 1. Large values of test supermartingales provide evidence against H. As a result, test supermartingales are an effective tool for rejecting H, particularly when the p-values obtained are very small and serve as certificates against the null hypothesis. Examples include the rejection of local realism as an explanation of Bell test experiments in the foundations of physics and the certification of entanglement in quantum information science. Test supermartingales have the advantage of being adaptable during an experiment and allowing for arbitrary stop** rules. By inversion of acceptance regions, they can also be used to determine confidence sets. We use an example to compare the performance of test supermartingales for computing p-values and confidence intervals to Chernoff-Hoeffding bounds and the "exact" p-value. The example is the problem of inferring the probability of success in a sequence of Bernoulli trials. There is a cost in using a technique that has no restriction on stop** rules, and for a particular test supermartingale, our study quantifies this cost.
△ Less
Submitted 12 September, 2017;
originally announced September 2017.
-
Spectral model selection in the electronic measurement of the Boltzmann constant by Johnson noise thermometry
Authors:
Kevin J Coakley,
Jifeng Qu
Abstract:
In the electronic measurement of the Boltzmann constant based on Johnson noise thermometry, the ratio of the power spectral densities of thermal noise across a resistor at the triple point of water, and pseudo-random noise synthetically generated by a quantum-accurate voltage-noise source is constant to within 1 part in a billion for frequencies up to 1 GHz. Given this ratio, and the values of oth…
▽ More
In the electronic measurement of the Boltzmann constant based on Johnson noise thermometry, the ratio of the power spectral densities of thermal noise across a resistor at the triple point of water, and pseudo-random noise synthetically generated by a quantum-accurate voltage-noise source is constant to within 1 part in a billion for frequencies up to 1 GHz. Given this ratio, and the values of other known or measured parameters, one can determine the Boltzmann constant. Due, in part, to mismatch between transmission lines, the experimental ratio spectrum varies with frequency. We model this spectrum as an even polynomial function of frequency where the constant term in the polynomial determines the Boltzmann constant. When determining this constant (offset) from experimental data, the assumed complexity of the ratio spectrum model and the maximum frequency analyzed (fitting bandwidth) dramatically affects results. We select the complexity of the model by cross-validation. For each of many fitting bandwidths, we determine the component of uncertainty of the offset term that accounts for random and systematic effects associated with imperfect knowledge of model complexity. We select the fitting bandwidth that minimizes this uncertainty. In the most recent measurement of the Boltzmann constant, results were determined, in part, by application of an earlier version of the method described here. Here, we extend the earlier analysis by considering a broader range of fitting bandwidths and quantify an additional component of uncertainty that accounts for imperfect performance of our fitting bandwidth selection method. For idealized simulated data our method correctly selects the true complexity of the ratio spectrum model for all cases considered. A new analysis of data from the recent experiment yields evidence for a temporal trend in the offset parameters.
△ Less
Submitted 2 February, 2017; v1 submitted 19 June, 2016;
originally announced June 2016.
-
High-Fidelity Universal Gate Set for $^9$Be$^+$ Ion Qubits
Authors:
J. P. Gaebler,
T. R. Tan,
Y. Lin,
Y. Wan,
R. Bowler,
A. C. Keith,
S. Glancy,
K. Coakley,
E. Knill,
D. Leibfried,
D. J. Wineland
Abstract:
We report high-fidelity laser-beam-induced quantum logic gates on magnetic-field-insensitive qubits comprised of hyperfine states in $^{9}$Be$^+$ ions with a memory coherence time of more than 1 s. We demonstrate single-qubit gates with error per gate of $3.8(1)\times 10^{-5}$. By creating a Bell state with a deterministic two-qubit gate, we deduce a gate error of $8(4)\times10^{-4}$. We character…
▽ More
We report high-fidelity laser-beam-induced quantum logic gates on magnetic-field-insensitive qubits comprised of hyperfine states in $^{9}$Be$^+$ ions with a memory coherence time of more than 1 s. We demonstrate single-qubit gates with error per gate of $3.8(1)\times 10^{-5}$. By creating a Bell state with a deterministic two-qubit gate, we deduce a gate error of $8(4)\times10^{-4}$. We characterize the errors in our implementation and discuss methods to further reduce imperfections towards values that are compatible with fault-tolerant processing at realistic overhead.
△ Less
Submitted 31 March, 2016;
originally announced April 2016.
-
Preparation of entangled states through Hilbert space engineering
Authors:
Y. Lin,
J. P. Gaebler,
F. Reiter,
T. R. Tan,
R. Bowler,
Y. Wan,
A. Keith,
E. Knill,
S. Glancy,
K. Coakley,
A. S. Sørensen,
D. Leibfried,
D. J. Wineland
Abstract:
Entangled states are a crucial resource for quantum-based technologies such as quantum computers and quantum communication systems (1,2). Exploring new methods for entanglement generation is important for diversifying and eventually improving current approaches. Here, we create entanglement in atomic ions by applying laser fields to constrain the evolution to a restricted number of states, in an a…
▽ More
Entangled states are a crucial resource for quantum-based technologies such as quantum computers and quantum communication systems (1,2). Exploring new methods for entanglement generation is important for diversifying and eventually improving current approaches. Here, we create entanglement in atomic ions by applying laser fields to constrain the evolution to a restricted number of states, in an approach that has become known as "quantum Zeno dynamics" (3-5). With two trapped $^9\rm{Be}^+$ ions, we obtain Bell state fidelities up to $0.990^{+2}_{-5}$, with three ions, a W-state (6) fidelity of $0.910^{+4}_{-7}$ is obtained. Compared to other methods of producing entanglement in trapped ions, this procedure is relatively insensitive to certain imperfections such as fluctuations in laser intensity, laser frequency, and ion-motion frequencies.
△ Less
Submitted 11 March, 2016;
originally announced March 2016.
-
Precision Measurement of the Radiative $\Beta$ Decay of the Free Neutron
Authors:
M. J. Bales,
R. Alarcon,
C. D. Bass,
E. J. Beise,
H. Breuer,
J. Byrne,
T. E. Chupp,
K. J. Coakley,
R. L. Cooper,
M. S. Dewey,
S. Gardner,
T. R. Gentile,
D. He,
H. P. Mumm,
J. S. Nico,
B. O'Neill,
A. K. Thompson,
F. E. Wietfeldt
Abstract:
The standard model predicts that, in addition to a proton, an electron, and an antineutrino, a continuous spectrum of photons is emitted in the $β$ decay of the free neutron. We report on the RDK II experiment which measured the photon spectrum using two different detector arrays. An annular array of bismuth germanium oxide scintillators detected photons from 14 to 782~keV. The spectral shape was…
▽ More
The standard model predicts that, in addition to a proton, an electron, and an antineutrino, a continuous spectrum of photons is emitted in the $β$ decay of the free neutron. We report on the RDK II experiment which measured the photon spectrum using two different detector arrays. An annular array of bismuth germanium oxide scintillators detected photons from 14 to 782~keV. The spectral shape was consistent with theory, and we determined a branching ratio of 0.00335 $\pm$ 0.00005 [stat] $\pm$ 0.00015 [syst]. A second detector array of large area avalanche photodiodes directly detected photons from 0.4 to 14~keV. For this array, the spectral shape was consistent with theory, and the branching ratio was determined to be 0.00582 $\pm$ 0.00023 [stat] $\pm$ 0.00062 [syst]. We report the first precision test of the shape of the photon energy spectrum from neutron radiative decay and a substantially improved determination of the branching ratio over a broad range of photon energies.
△ Less
Submitted 26 May, 2016; v1 submitted 1 March, 2016;
originally announced March 2016.
-
A strong loophole-free test of local realism
Authors:
Lynden K. Shalm,
Evan Meyer-Scott,
Bradley G. Christensen,
Peter Bierhorst,
Michael A. Wayne,
Martin J. Stevens,
Thomas Gerrits,
Scott Glancy,
Deny R. Hamel,
Michael S. Allman,
Kevin J. Coakley,
Shellee D. Dyer,
Carson Hodge,
Adriana E. Lita,
Varun B. Verma,
Camilla Lambrocco,
Edward Tortorici,
Alan L. Migdall,
Yanbao Zhang,
Daniel R. Kumor,
William H. Farr,
Francesco Marsili,
Matthew D. Shaw,
Jeffrey A. Stern,
Carlos Abellán
, et al. (9 additional authors not shown)
Abstract:
We present a loophole-free violation of local realism using entangled photon pairs. We ensure that all relevant events in our Bell test are spacelike separated by placing the parties far enough apart and by using fast random number generators and high-speed polarization measurements. A high-quality polarization-entangled source of photons, combined with high-efficiency, low-noise, single-photon de…
▽ More
We present a loophole-free violation of local realism using entangled photon pairs. We ensure that all relevant events in our Bell test are spacelike separated by placing the parties far enough apart and by using fast random number generators and high-speed polarization measurements. A high-quality polarization-entangled source of photons, combined with high-efficiency, low-noise, single-photon detectors, allows us to make measurements without requiring any fair-sampling assumptions. Using a hypothesis test, we compute p-values as small as $5.9\times 10^{-9}$ for our Bell violation while maintaining the spacelike separation of our events. We estimate the degree to which a local realistic system could predict our measurement choices. Accounting for this predictability, our smallest adjusted p-value is $2.3 \times 10^{-7}$. We therefore reject the hypothesis that local realism governs our experiment.
△ Less
Submitted 6 September, 2016; v1 submitted 10 November, 2015;
originally announced November 2015.
-
Stochastic modeling and survival analysis of marginally trapped neutrons for a magnetic trap** neutron lifetime experiment
Authors:
K. J. Coakley,
M. S. Dewey,
M. G. Huber,
P. R. Huffman,
C. R. Huffer,
D. E. Marley,
H. P. Mumm,
C. M. O'Shaughnessy,
K. W. Schelhammer,
A. K. Thompson,
A. T. Yue
Abstract:
In a variety of neutron lifetime experiments, in addition to $β-$decay, neutrons can be lost by other mechanisms including wall losses. Failure to account for these other loss mechanisms produces systematic measurement error and associated systematic uncertainties in neutron lifetime measurements. In this work, we develop a physical model for neutron wall losses and construct a competing risks sur…
▽ More
In a variety of neutron lifetime experiments, in addition to $β-$decay, neutrons can be lost by other mechanisms including wall losses. Failure to account for these other loss mechanisms produces systematic measurement error and associated systematic uncertainties in neutron lifetime measurements. In this work, we develop a physical model for neutron wall losses and construct a competing risks survival analysis model to account for losses due to the joint effect of $β-$decay losses, wall losses of marginally trapped neutrons, and an additional absorption mechanism. We determine the survival probability function associated with the wall loss mechanism by a Monte Carlo method. Based on a fit of the competing risks model to a subset of the NIST experimental data, we determine the mean lifetime of trapped neutrons to be approximately 700 s -- considerably less than the current best estimate of (880.1 $\pm$ 1.1) s promulgated by the Particle Data Group [1]. Currently, experimental studies are underway to determine if this discrepancy can be explained by neutron capture by ${}^3$He impurities in the trap** volume. Analysis of the full NIST data will be presented in a later publication.
△ Less
Submitted 10 August, 2015;
originally announced August 2015.
-
Nonproportionality in the scintillation light yield of bismuth germanate
Authors:
T. R. Gentile,
M. J. Bales,
H. Breuer,
T. E. Chupp,
K. J. Coakley,
R. L. Cooper,
J. S. Nico,
B. O'Neill
Abstract:
We present measurements of nonproportionality in the scintillation light yield of bismuth germanate (BGO) for gamma-rays with energies between 6 keV and 662 keV. The scintillation light was read out by avalanche photodiodes (APDs) with both the BGO crystals and APDs operated at a temperature of approximately 90 K. Data were obtained using radioisotope sources to illuminate both a single BGO crysta…
▽ More
We present measurements of nonproportionality in the scintillation light yield of bismuth germanate (BGO) for gamma-rays with energies between 6 keV and 662 keV. The scintillation light was read out by avalanche photodiodes (APDs) with both the BGO crystals and APDs operated at a temperature of approximately 90 K. Data were obtained using radioisotope sources to illuminate both a single BGO crystal in a small test cryostat and a 12-element detector in a neutron radiative beta-decay experiment. In addition one datum was obtained in a 4.6 T magnetic field based on the bismuth K x-ray escape peak produced by a continuum of background gamma rays in this apparatus. These measurements and comparison to prior results were motivated by an experiment to study the radiative decay mode of the free neutron. The combination of data taken under different conditions yields a reasonably consistent picture for BGO nonproportionality that should be useful for researchers employing BGO detectors at low gamma ray energies.
△ Less
Submitted 1 May, 2015;
originally announced May 2015.
-
Analysis of Coincidence-Time Loopholes in Experimental Bell Tests
Authors:
B. G. Christensen,
A. Hill,
P. G. Kwiat,
E. Knill,
S. W. Nam,
K. Coakley,
S. Glancy,
L. K. Shalm,
Y. Zhang
Abstract:
We apply a distance-based Bell-test analysis method [E. Knill et al., Phys. Rev. A. 91, 032105 (2015)] to three experimental data sets where conventional analyses failed or required additional assumptions. The first is produced from a new classical source exploiting a "coincidence-time loophole" for which standard analysis falsely shows a Bell violation. The second is from a source previously show…
▽ More
We apply a distance-based Bell-test analysis method [E. Knill et al., Phys. Rev. A. 91, 032105 (2015)] to three experimental data sets where conventional analyses failed or required additional assumptions. The first is produced from a new classical source exploiting a "coincidence-time loophole" for which standard analysis falsely shows a Bell violation. The second is from a source previously shown to violate a Bell inequality; the distance-based analysis agrees with the previous results but with fewer assumptions. The third data set does not show a violation with standard analysis despite the high source quality, but is shown to have a strong violation with the distance-based analysis method.
△ Less
Submitted 25 March, 2015;
originally announced March 2015.
-
Bell Inequalities for Continuously Emitting Sources
Authors:
Emanuel Knill,
Scott Glancy,
Sae Woo Nam,
Kevin Coakley,
Yanbao Zhang
Abstract:
A common experimental strategy for demonstrating non-classical correlations is to show violation of a Bell inequality by measuring a continuously emitted stream of entangled photon pairs. The measurements involve the detection of photons by two spatially separated parties. The detection times are recorded and compared to quantify the violation. The violation critically depends on determining which…
▽ More
A common experimental strategy for demonstrating non-classical correlations is to show violation of a Bell inequality by measuring a continuously emitted stream of entangled photon pairs. The measurements involve the detection of photons by two spatially separated parties. The detection times are recorded and compared to quantify the violation. The violation critically depends on determining which detections are coincident. Because the recorded detection times have "jitter", coincidences cannot be inferred perfectly. In the presence of settings-dependent timing errors, this can allow a local-realistic system to show apparent violation--the so-called "coincidence loophole". Here we introduce a family of Bell inequalities based on signed, directed distances between the parties' sequences of recorded timetags. Given that the timetags are recorded for synchronized, fixed observation periods and that the settings choices are random and independent of the source, violation of these inequalities unambiguously shows non-classical correlations violating local realism. Distance-based Bell inequalities are generally useful for two-party configurations where the effective size of the measurement outcome space is large or infinite. We show how to systematically modify the underlying Bell functions to improve the signal to noise ratio and to quantify the significance of the violation.
△ Less
Submitted 26 September, 2014;
originally announced September 2014.
-
Improving Photoelectron Counting and Particle Identification in Scintillation Detectors with Bayesian Techniques
Authors:
M. Akashi-Ronquest,
P. -A. Amaudruz,
M. Batygov,
B. Beltran,
M. Bodmer,
M. G. Boulay,
B. Broerman,
B. Buck,
A. Butcher,
B. Cai,
T. Caldwell,
M. Chen,
Y. Chen,
B. Cleveland,
K. Coakley,
K. Dering,
F. A. Duncan,
J. A. Formaggio,
R. Gagnon,
D. Gastler,
F. Giuliani,
M. Gold,
V. V. Golovko,
P. Gorel,
K. Graham
, et al. (57 additional authors not shown)
Abstract:
Many current and future dark matter and neutrino detectors are designed to measure scintillation light with a large array of photomultiplier tubes (PMTs). The energy resolution and particle identification capabilities of these detectors depend in part on the ability to accurately identify individual photoelectrons in PMT waveforms despite large variability in pulse amplitudes and pulse pileup. We…
▽ More
Many current and future dark matter and neutrino detectors are designed to measure scintillation light with a large array of photomultiplier tubes (PMTs). The energy resolution and particle identification capabilities of these detectors depend in part on the ability to accurately identify individual photoelectrons in PMT waveforms despite large variability in pulse amplitudes and pulse pileup. We describe a Bayesian technique that can identify the times of individual photoelectrons in a sampled PMT waveform without deconvolution, even when pileup is present. To demonstrate the technique, we apply it to the general problem of particle identification in single-phase liquid argon dark matter detectors. Using the output of the Bayesian photoelectron counting algorithm described in this paper, we construct several test statistics for rejection of backgrounds for dark matter searches in argon. Compared to simpler methods based on either observed charge or peak finding, the photoelectron counting technique improves both energy resolution and particle identification of low energy events in calibration data from the DEAP-1 detector and simulation of the larger MiniCLEAN dark matter detector.
△ Less
Submitted 12 December, 2014; v1 submitted 8 August, 2014;
originally announced August 2014.
-
Update on the MiniCLEAN Dark Matter Experiment
Authors:
K. Rielage,
M. Akashi-Ronquest,
M. Bodmer,
R. Bourque,
B. Buck,
A. Butcher,
T. Caldwell,
Y. Chen,
K. Coakley,
E. Flores,
J. A. Formaggio,
D. Gastler,
F. Giuliani,
M. Gold,
E. Grace,
J. Griego,
N. Guerrero,
V. Guiseppe,
R. Henning,
A. Hime,
S. Jaditz,
C. Kachulis,
E. Kearns,
J. Kelsey,
J. R. Klein
, et al. (21 additional authors not shown)
Abstract:
The direct search for dark matter is entering a period of increased sensitivity to the hypothetical Weakly Interacting Massive Particle (WIMP). One such technology that is being examined is a scintillation only noble liquid experiment, MiniCLEAN. MiniCLEAN utilizes over 500 kg of liquid cryogen to detect nuclear recoils from WIMP dark matter and serves as a demonstration for a future detector of o…
▽ More
The direct search for dark matter is entering a period of increased sensitivity to the hypothetical Weakly Interacting Massive Particle (WIMP). One such technology that is being examined is a scintillation only noble liquid experiment, MiniCLEAN. MiniCLEAN utilizes over 500 kg of liquid cryogen to detect nuclear recoils from WIMP dark matter and serves as a demonstration for a future detector of order 50 to 100 tonnes. The liquid cryogen is interchangeable between argon and neon to study the A$^{2}$ dependence of the potential signal and examine backgrounds. MiniCLEAN utilizes a unique modular design with spherical geometry to maximize the light yield using cold photomultiplier tubes in a single-phase detector. Pulse shape discrimination techniques are used to separate nuclear recoil signals from electron recoil backgrounds. MiniCLEAN will be spiked with additional $^{39}$Ar to demonstrate the effective reach of the pulse shape discrimination capability. Assembly of the experiment is underway at SNOLAB and an update on the project is given.
△ Less
Submitted 19 March, 2014;
originally announced March 2014.
-
A gamma- and X-ray detector for cryogenic, high magnetic field applications
Authors:
R. L. Cooper,
R. Alarcon,
M. J. Bales,
C. D. Bass,
E. J. Beise,
H. Breuer,
J. Byrne,
T. E. Chupp,
K. J. Coakley,
M. S. Dewey,
C. Fu,
T. R. Gentile,
H. P. Mumm,
J. S. Nico,
B. O'Neill,
K. Pulliam,
A. K. Thompson,
F. E. Wietfeldt
Abstract:
As part of an experiment to measure the spectrum of photons emitted in beta-decay of the free neutron, we developed and operated a detector consisting of 12 bismuth germanate (BGO) crystals coupled to avalanche photodiodes (APDs). The detector was operated near liquid nitrogen temperature in the bore of a superconducting magnet and registered photons with energies from 5 keV to 1000 keV. To enlarg…
▽ More
As part of an experiment to measure the spectrum of photons emitted in beta-decay of the free neutron, we developed and operated a detector consisting of 12 bismuth germanate (BGO) crystals coupled to avalanche photodiodes (APDs). The detector was operated near liquid nitrogen temperature in the bore of a superconducting magnet and registered photons with energies from 5 keV to 1000 keV. To enlarge the detection range, we also directly detected soft X-rays with energies between 0.2 keV and 20 keV with three large area APDs. The construction and operation of the detector is presented, as well as information on operation of APDs at cryogenic temperatures.
△ Less
Submitted 18 July, 2012;
originally announced July 2012.
-
Scintillation yield and time dependence from electronic and nuclear recoils in liquid neon
Authors:
W. H. Lippincott,
K. J. Coakley,
D. Gastler,
E. Kearns,
D. N. McKinsey,
J. A. Nikkel
Abstract:
We have performed measurements of scintillation light in liquid neon, observing a signal yield in our detector as high as (3.5 $\pm$ 0.4) photoelectrons/keV. We measure pulse shape discrimination efficiency between electronic and nuclear recoils in liquid neon from 50 and 300 keV nuclear recoil energy. We also measure the \leff\, parameter in liquid neon between 30 and 370 keV nuclear recoil energ…
▽ More
We have performed measurements of scintillation light in liquid neon, observing a signal yield in our detector as high as (3.5 $\pm$ 0.4) photoelectrons/keV. We measure pulse shape discrimination efficiency between electronic and nuclear recoils in liquid neon from 50 and 300 keV nuclear recoil energy. We also measure the \leff\, parameter in liquid neon between 30 and 370 keV nuclear recoil energy, observing an average \leff$=0.24$ above 50 keV. We observe a dependence of the scintillation time distribution and signal yield on the pressure and temperature of the liquid neon.
△ Less
Submitted 13 August, 2012; v1 submitted 14 November, 2011;
originally announced November 2011.
-
Fast Neutron Detection with 6Li-loaded Liquid Scintillator
Authors:
B. M. Fisher,
J. N. Abdurashitov,
K. J. Coakley,
V. N. Gavrin,
D. M. Gilliam,
J. S. Nico,
A. A. Shikhin,
A. K. Thompson,
D. F. Vecchia,
V. E. Yants
Abstract:
We report on the development of a fast neutron detector using a liquid scintillator doped with enriched Li-6. The lithium was introduced in the form of an aqueous LiCl micro-emulsion with a di-isopropylnaphthalene-based liquid scintillator. A Li-6 concentration of 0.15 % by weight was obtained. A 125 mL glass cell was filled with the scintillator and irradiated with fission-source neutrons. Fast n…
▽ More
We report on the development of a fast neutron detector using a liquid scintillator doped with enriched Li-6. The lithium was introduced in the form of an aqueous LiCl micro-emulsion with a di-isopropylnaphthalene-based liquid scintillator. A Li-6 concentration of 0.15 % by weight was obtained. A 125 mL glass cell was filled with the scintillator and irradiated with fission-source neutrons. Fast neutrons may produce recoil protons in the scintillator, and those neutrons that thermalize within the detector volume can be captured on the Li-6. The energy of the neutron may be determined by the light output from recoiling protons, and the capture of the delayed thermal neutron reduces background events. In this paper, we discuss the development of this 6Li-loaded liquid scintillator, demonstrate the operation of it in a detector, and compare its efficiency and capture lifetime with Monte Carlo simulations. Data from a boron-loaded plastic scintillator were acquired for comparison. We also present a pulse-shape discrimination method for differentiating between electronic and nuclear recoil events based on the Matusita distance between a normalized observed waveform and nuclear and electronic recoil template waveforms. The details of the measurements are discussed along with specifics of the data analysis and its comparison with the Monte Carlo simulation.
△ Less
Submitted 22 June, 2011;
originally announced June 2011.
-
Measuring the Neutron Lifetime Using Magnetically Trapped Neutrons
Authors:
C. M. O'Shaughnessy,
R. Golub,
K. W. Schelhammer,
C. M. Swank,
P. -N. Seo,
P. R. Huffman,
S. N. Dzhosyuk,
C. E. H. Mattoni,
L. Yang,
J. M. Doyle,
K. J. Coakley,
A. K. Thompson,
H. P. Mumm,
S. K. Lamoreaux,
G. Yang
Abstract:
The neutron beta-decay lifetime plays an important role both in understanding weak interactions within the framework of the Standard Model and in theoretical predictions of the primordial abundance of 4He in Big Bang Nucleosynthesis. In previous work, we successfully demonstrated the trap** of ultracold neutrons (UCN) in a conservative potential magnetic trap. A major upgrade of the apparatus…
▽ More
The neutron beta-decay lifetime plays an important role both in understanding weak interactions within the framework of the Standard Model and in theoretical predictions of the primordial abundance of 4He in Big Bang Nucleosynthesis. In previous work, we successfully demonstrated the trap** of ultracold neutrons (UCN) in a conservative potential magnetic trap. A major upgrade of the apparatus is nearing completion at the National Institute of Standards and Technology Center for Neutron Research (NCNR). In our approach, a beam of 0.89 nm neutrons is incident on a superfluid 4He target within the minimum field region of an Ioffe-type magnetic trap. A fraction of the neutrons is downscattered in the helium to energies <200 neV, and those in the appropriate spin state become trapped. The inverse process is suppressed by the low phonon density of helium at temperatures less than 200 mK, allowing the neutron to travel undisturbed. When the neutron decays the energetic electron ionizes the helium, producing scintillation light that is detected using photomultiplier tubes. Statistical limitations of the previous apparatus will be alleviated by significant increases in field strength and trap volume resulting in twenty times more trapped neutrons.
△ Less
Submitted 31 March, 2009;
originally announced March 2009.
-
Frequentist Coverage Properties of Uncertainty Intervals for Weak Poisson Signals in the Presence of Background
Authors:
K. J. Coakley,
J. D. Splett,
D. S. Simons
Abstract:
We construct uncertainty intervals for weak Poisson signals in the presence of background. We consider the case where a primary experiment yields a realization of the signal plus background, and a second experiment yields a realization of the background. The data acquisitions times for the background-only experiment,T_bg, and the primary experiment,T, are selected so that their ratio varies from…
▽ More
We construct uncertainty intervals for weak Poisson signals in the presence of background. We consider the case where a primary experiment yields a realization of the signal plus background, and a second experiment yields a realization of the background. The data acquisitions times for the background-only experiment,T_bg, and the primary experiment,T, are selected so that their ratio varies from 1 to 25. The expected number of background counts in the primary experiment varies from 0.2 to 2. We construct 90 and 95 percent confidence intervals based on a propagation-of-errors method as well as two implementations of a Neyman procedure where acceptance regions are constructed based on a likelihood-ratio criterion that automatically determines whether the resulting confidence interval is one-sided or two-sided. The first Neyman procedure (due to Feldman and Cousins) neglects uncertainty in the background. In the other Neyman procedure, we account for uncertainty in the background with a parametric bootstrap method. We also construct minimum length Bayesian credibility intervals. For each method, we test for the presence of a signal based on the value of the lower endpoint of the uncertainty interval. When T_bg/T is 5 or more and the expected background is 2 or less, the Feldman Cousins method outperforms the other methods considered.
△ Less
Submitted 27 December, 2009; v1 submitted 24 April, 2008;
originally announced April 2008.
-
Scintillation time dependence and pulse shape discrimination in liquid argon
Authors:
W. H. Lippincott,
K. J. Coakley,
D. Gastler,
A. Hime,
E. Kearns,
D. N. McKinsey,
J. A. Nikkel,
L. C. Stonehill
Abstract:
Using a single-phase liquid argon detector with a signal yield of 4.85 photoelectrons per keV of electronic-equivalent recoil energy (keVee), we measure the scintillation time dependence of both electronic and nuclear recoils in liquid argon down to 5 keVee. We develop two methods of pulse shape discrimination to distinguish between electronic and nuclear recoils. Using one of these methods, we…
▽ More
Using a single-phase liquid argon detector with a signal yield of 4.85 photoelectrons per keV of electronic-equivalent recoil energy (keVee), we measure the scintillation time dependence of both electronic and nuclear recoils in liquid argon down to 5 keVee. We develop two methods of pulse shape discrimination to distinguish between electronic and nuclear recoils. Using one of these methods, we measure a background and statistics-limited level of electronic recoil contamination to be $7.6\times10^{-7}$ between 60 and 128 keV of nuclear recoil energy (keVr) for a nuclear recoil acceptance of 50% with no nuclear recoil-like events above 72 keVr. Finally, we develop a maximum likelihood method of pulse shape discrimination using the measured scintillation time dependence and predict the sensitivity to WIMP-nucleon scattering in three configurations of a liquid argon dark matter detector.
△ Less
Submitted 23 September, 2008; v1 submitted 9 January, 2008;
originally announced January 2008.
-
Optimal Proton Trap** in a Neutron Lifetime Experiment
Authors:
Kevin J. Coakley
Abstract:
In a neutron lifetime experiment conducted at the National Institute of Standards and Technology, protons produced by neutron decay events are confined in a Penning trap. In each run of the experiment, there is a trap** stage of duration $τ$. After the trap** stage, protons are purged from the trap. A proton detector provides incomplete information because it goes dead after detecting the fi…
▽ More
In a neutron lifetime experiment conducted at the National Institute of Standards and Technology, protons produced by neutron decay events are confined in a Penning trap. In each run of the experiment, there is a trap** stage of duration $τ$. After the trap** stage, protons are purged from the trap. A proton detector provides incomplete information because it goes dead after detecting the first of any purged protons. Further, there is a dead time $δ$ between the end of the trap** stage in one run and the beginning of the next trap** stage in the next run. Based on the fraction of runs where a proton is detected, I estimate the trap** rate $λ$ by the method of maximum likelihood. I show that the expected value of the maximum likelihood estimate is infinite. To obtain a maximum likelihood estimate with a finite expected value and a well-defined and finite variance, I restrict attention to a subsample of all realizations of the data. This subsample excludes an exceedingly rare realization that yields an infinite-valued estimate of $λ$. I present asymptotically valid formulas for the bias, root-mean-square prediction error, and standard deviation of the maximum likelihood estimate of $λ$ for this subsample. Based on nominal values of $λ$ and the dead time $δ$, I determine the optimal duration of the trap** stage $τ$ by minimizing the root-mean-square prediction error of the estimate.
△ Less
Submitted 28 March, 2007; v1 submitted 4 December, 2006;
originally announced December 2006.
-
Neutrino Detection With CLEAN
Authors:
D. N. McKinsey,
K. J. Coakley
Abstract:
This article describes CLEAN, an approach to the detection of low-energy solar neutrinos and neutrinos released from supernovae. The CLEAN concept is based on the detection of elastic scattering events (neutrino-electron scattering and neutrino-nuclear scattering) in liquified noble gases such as liquid helium, liquid neon, and liquid xenon, all of which scintillate brightly in the ultraviolet.…
▽ More
This article describes CLEAN, an approach to the detection of low-energy solar neutrinos and neutrinos released from supernovae. The CLEAN concept is based on the detection of elastic scattering events (neutrino-electron scattering and neutrino-nuclear scattering) in liquified noble gases such as liquid helium, liquid neon, and liquid xenon, all of which scintillate brightly in the ultraviolet. Key to the CLEAN technique is the use of a thin film of wavelength-shifting fluor to convert the ultraviolet scintillation light to the visible. This allows the same liquid to be used as both a passive shielding medium and an active self-shielding detector, allowing lower intrinsic radioactive backgrounds at low energies. Liquid neon is a particularly promising medium for CLEAN. Because liquid neon has a high scintillation yield, has no long-lived radioactive isotopes, and can be easily purified by use of cold traps, it is an ideal medium for the detection of rare nuclear events. In addition, neon is inexpensive, dense, and transparent to its own scintillation light, making it practical for use in a large self-shielding apparatus. Monte Carlo simulations of gamma ray backgrounds have been performed assuming liquid neon as both shielding and detection medium. Gamma ray events occur with high probability in the outer parts of the detector. In contrast, neutrino scattering events occur uniformly throughout the detector. We discriminate background gamma ray events from events of interest based on a spatial Maximum Likelihood method estimate of event location. Background estimates for CLEAN are presented, as well as an evaluation of the sensitivity of the detector for $p-p$ neutrinos. Given these simulations, the physics potential of the CLEAN approach is evaluated.
△ Less
Submitted 8 February, 2004; v1 submitted 31 January, 2004;
originally announced February 2004.
-
Spatial methods for event reconstruction in CLEAN
Authors:
Kevin J. Coakley,
Daniel N. McKinsey
Abstract:
In CLEAN (Cryogenic Low Energy Astrophysics with Noble gases), a proposed neutrino and dark matter detector, background discrimination is possible if one can determine the location of an ionizing radiation event with high accuracy. We simulate ionizing radiation events that produce multiple scintillation photons within a spherical detection volume filled with liquid neon. We estimate the radial…
▽ More
In CLEAN (Cryogenic Low Energy Astrophysics with Noble gases), a proposed neutrino and dark matter detector, background discrimination is possible if one can determine the location of an ionizing radiation event with high accuracy. We simulate ionizing radiation events that produce multiple scintillation photons within a spherical detection volume filled with liquid neon. We estimate the radial location of a particular ionizing radiation event based on the observed count data corresponding to that event. The count data are collected by detectors mounted at the spherical boundary of the detection volume. We neglect absorption, but account for Rayleigh scattering. To account for wavelength-shifting of the scintillation light, we assume that photons are absorbed and re-emitted at the detectors. Here, we develop spatial Maximum Likelihood methods for event reconstruction, and study their performance in computer simulation experiments. We also study a method based on the centroid of the observed count data. We calibrate our estimates based on training data.
△ Less
Submitted 4 September, 2003;
originally announced September 2003.
-
Supernova Observation Via Neutrino-Nucleus Elastic Scattering in the CLEAN Detector
Authors:
C. J. Horowitz,
K. J. Coakley,
D. N. McKinsey
Abstract:
Development of large mass detectors for low-energy neutrinos and dark matter may allow supernova detection via neutrino-nucleus elastic scattering. An elastic-scattering detector could observe a few, or more, events per ton for a galactic supernova at 10 kpc ($3.1 \times 10^{20}$ m). This large yield, a factor of at least 20 greater than that for existing light-water detectors, arises because of…
▽ More
Development of large mass detectors for low-energy neutrinos and dark matter may allow supernova detection via neutrino-nucleus elastic scattering. An elastic-scattering detector could observe a few, or more, events per ton for a galactic supernova at 10 kpc ($3.1 \times 10^{20}$ m). This large yield, a factor of at least 20 greater than that for existing light-water detectors, arises because of the very large coherent cross section and the sensitivity to all flavors of neutrinos and antineutrinos. An elastic scattering detector can provide important information on the flux and spectrum of $ν_μ$ and $ν_τ$ from supernovae. We consider many detectors and a range of target materials from $^4$He to $^{208}$Pb. Monte Carlo simulations of low-energy backgrounds are presented for the liquid-neon-based Cryogenic Low Energy Astrophysics with Noble gases (CLEAN) detector. The simulated background is much smaller than the expected signal from a galactic supernova.
△ Less
Submitted 4 February, 2003;
originally announced February 2003.
-
Magnetic trap** of ultracold neutrons
Authors:
C. R. Brome,
J. S. Butterworth,
S. N. Dzhosyuk,
C. E. H. Mattoni,
D. N. McKinsey,
J. M. Doyle,
P. R. Huffman,
M. S. Dewey,
F. E. Wietfeldt,
R. Golub,
K. Habicht,
G. L. Greene,
S. K. Lamoreaux,
K. J. Coakley
Abstract:
Three-dimensional magnetic confinement of neutrons is reported. Neutrons are loaded into an Ioffe-type superconducting magnetic trap through inelastic scattering of cold neutrons with 4He. Scattered neutrons with sufficiently low energy and in the appropriate spin state are confined by the magnetic field until they decay. The electron resulting from neutron decay produces scintillations in the l…
▽ More
Three-dimensional magnetic confinement of neutrons is reported. Neutrons are loaded into an Ioffe-type superconducting magnetic trap through inelastic scattering of cold neutrons with 4He. Scattered neutrons with sufficiently low energy and in the appropriate spin state are confined by the magnetic field until they decay. The electron resulting from neutron decay produces scintillations in the liquid helium bath that results in a pulse of extreme ultraviolet light. This light is frequency downconverted to the visible and detected. Results are presented in which 500 +/- 155 neutrons are magnetically trapped in each loading cycle, consistent with theoretical predictions. The lifetime of the observed signal, 660 s +290/-170 s, is consistent with the neutron beta-decay lifetime.
△ Less
Submitted 13 March, 2001;
originally announced March 2001.
-
Magnetic Trap** of Neutrons
Authors:
P. R. Huffman,
C. R. Brome,
J. S. Butterworth,
K. J. Coakley,
M. S. Dewey,
S. N. Dzhosyuk,
R. Golub,
G. L. Greene,
K. Habicht,
S. K. Lamoreaux,
C. E. H. Mattoni,
D. N. McKinsey,
F. E. Wietfeldt,
J. M. Doyle
Abstract:
Accurate measurement of the lifetime of the neutron (which is unstable to beta decay) is important for understanding the weak nuclear force and the creation of matter during the Big Bang. Previous measurements of the neutron lifetime have mainly been limited by certain systematic errors; however, these could in principle be avoided by performing measurements on neutrons stored in a magnetic trap…
▽ More
Accurate measurement of the lifetime of the neutron (which is unstable to beta decay) is important for understanding the weak nuclear force and the creation of matter during the Big Bang. Previous measurements of the neutron lifetime have mainly been limited by certain systematic errors; however, these could in principle be avoided by performing measurements on neutrons stored in a magnetic trap. Neutral and charged particle traps are widely used tool for studying both composite and elementary particles, because they allow long interaction times and isolation from perturbing environments. Here we report the magnetic trap** of neutrons. The trap** region is filled with superfluid 4-He, which is used to load neutrons into the trap and as a scintillator to detect their decay. Neutrons have a lifetime in the trap of 750 +330/-200 seconds, mainly limited by their beta decay rather than trap losses. Our experiment verifies theoretical predictions regarding the loading process and magnetic trap** of neutrons. Further refinement of this method should lead to improved precision in the neutron lifetime measurement.
△ Less
Submitted 7 January, 2000;
originally announced January 2000.