Initial experiences with Direct Imaging of Neuronal Activity (DIANA) in humans
Authors:
Shota Hodono,
Reuben Rideaux,
Timo van Kerkoerle,
Martijn A. Cloos
Abstract:
Functional MRI (fMRI) has been widely used to study activity patterns in the human brain. It infers neuronal activity from the associated hemodynamic response, which fundamentally limits its spatial and temporal specificity. In mice, the Direct Imaging of Neuronal Activity (DIANA) method revealed MRI signals that correlated with intracellular voltage changes, showing high spatial and temporal spec…
▽ More
Functional MRI (fMRI) has been widely used to study activity patterns in the human brain. It infers neuronal activity from the associated hemodynamic response, which fundamentally limits its spatial and temporal specificity. In mice, the Direct Imaging of Neuronal Activity (DIANA) method revealed MRI signals that correlated with intracellular voltage changes, showing high spatial and temporal specificity. In this work we attempted DIANA in humans. Four visual paradigms were tested, exploring different stimulus types (flickering noise patterns, and naturalistic images) and stimulus durations (50-200ms). Regions of interest (ROI) were derived from traditional fMRI acquisitions and anatomical scans. When using small manually drawn ROI, signals were detected that resembled possible functional activity. However, increasing the stimulus duration did not lead to corroborating signal changes. Moreover, these signals disappeared when averaged over larger functionally or anatomically derived ROI. Further analysis of the data highlighted, DIANA's sensitivity to inflow effects and subject motion. Therefore, care should be taken not to mistake artifacts for neuronal activity. Although we did not yet observe clear DIANA signals in humans, it is possible that a higher spatial resolution is needed to separate signals with opposite signs in different laminar compartments. However, obtaining such data may be particularly challenging because repetitive experiments with short interstimulus intervals can be strenuous for the subjects. To obtain better data, improvements in sequence and stimulus designs are needed to maximize the DIANA signal and minimize confounds. However, without a clear understanding of DIANA's biophysical underpinnings it is difficult to do so. Therefore, it may be more effective to first study DIANA's biophysical underpinnings in a controlled, yet biologically revenant, setting.
△ Less
Submitted 28 February, 2023;
originally announced March 2023.
-
Optimization of MR Fingerprinting for Free-Breathing Quantitative Abdominal Imaging
Authors:
Max H. C. van Riel,
Zidan Yu,
Shota Hodono,
Ding Xia,
Hersh Chandarana,
Koji Fujimoto,
Martijn A. Cloos
Abstract:
In this work, we propose a free-breathing magnetic resonance fingerprinting method that can be used to obtain $B_1^+$-robust quantitative maps of the abdomen in a clinically acceptable time. A three-dimensional MR fingerprinting sequence with a radial stack-of-stars trajectory was implemented for quantitative abdominal imaging. The k-space acquisition ordering was adjusted to improve motion-robust…
▽ More
In this work, we propose a free-breathing magnetic resonance fingerprinting method that can be used to obtain $B_1^+$-robust quantitative maps of the abdomen in a clinically acceptable time. A three-dimensional MR fingerprinting sequence with a radial stack-of-stars trajectory was implemented for quantitative abdominal imaging. The k-space acquisition ordering was adjusted to improve motion-robustness. The flip angle pattern was optimized using the Cramér-Rao Lower Bound, and the encoding efficiency of sequences with 300, 600, 900, and 1800 flip angles was evaluated. To validate the sequence, a movable multicompartment phantom was developed. Reference multiparametric maps were acquired under stationary conditions using a previously validated MRF method. Periodic motion of the phantom was used to investigate the motion-robustness of the proposed sequence. The best performing sequence length (600 flip angles) was used to image the abdomen during a free-breathing volunteer scan. When using a series of 600 or more flip angles, the estimated $T_1$ values in the stationary phantom showed good agreement with the reference scan. Phantom experiments revealed that motion-related artefacts can appear in the quantitative maps, and confirmed that a motion-robust k-space ordering is essential in preventing these artefacts. The in vivo scan demonstrated that the proposed sequence can produce clean parameter maps while the subject breathes freely. Using this sequence, it is possible to generate $B_1^+$-robust quantitative maps of proton density, $T_1$, and $B_1^+$ under free-breathing conditions at a clinically usable resolution within 5 minutes.
△ Less
Submitted 4 June, 2020;
originally announced June 2020.
-
Magnetization Transfer in Magnetic Resonance Fingerprinting
Authors:
Tom Hilbert,
Ding Xia,
Kai Tobias Block,
Zidan Yu,
Riccardo Lattanzi,
Daniel K. Sodickson,
Tobias Kober,
Martijn A. Cloos
Abstract:
Purpose: To study the effects of magnetization transfer (MT, in which a semisolid spin pool interacts with the free pool), in the context of magnetic resonance fingerprinting (MRF).
Methods: Simulations and phantom experiments were performed to study the impact of MT on the MRF signal and its potential influence on T1 and T2 estimation. Subsequently, an MRF sequence implementing off-resonance MT…
▽ More
Purpose: To study the effects of magnetization transfer (MT, in which a semisolid spin pool interacts with the free pool), in the context of magnetic resonance fingerprinting (MRF).
Methods: Simulations and phantom experiments were performed to study the impact of MT on the MRF signal and its potential influence on T1 and T2 estimation. Subsequently, an MRF sequence implementing off-resonance MT pulses and a dictionary with an MT dimension by incorporating a two-pool model were used to estimate the fractional pool size in addition to the B1+, T1, and T2 values. The proposed method was evaluated in the human brain.
Results: Simulations and phantom experiments showed that an MRF signal obtained from a cross-linked bovine serum sample is influenced by MT. Using a dictionary based on an MT model, a better match between simulations and acquired MR signals can be obtained (NRMSE 1.3% versus 4.7%). Adding off-resonance MT pulses can improve the differentiation of MT from T1 and T2. In-vivo results showed that MT affects the MRF signals from white matter (fractional pool-size ~16%) and gray matter (fractional pool-size ~10%). Furthermore, longer T1 (~1060 ms versus ~860 ms) and T2 values (~47 ms versus ~35 ms) can be observed in white matter if MT is accounted for.
Conclusion: Our experiments demonstrated a potential influence of MT on the quantification of T1 and T2 with MRF. A model that encompasses MT effects can improve the accuracy of estimated relaxation parameters and allows quantification of the fractional pool size.
△ Less
Submitted 30 July, 2019;
originally announced July 2019.
-
Fingerprinting Orientation Distribution Functions in Diffusion MRI detects smaller crossing angles
Authors:
Steven H. Baete,
Martijn A. Cloos,
Ying-Chia Lin,
Dimitris G. Placantonakis,
Timothy Shepherd,
Fernando E. Boada
Abstract:
Diffusion tractography is routinely used to study white matter architecture and brain connectivity in vivo. A key step for successful tractography of neuronal tracts is the correct identification of tract directions in each voxel. Here we propose a fingerprinting-based methodology to identify these fiber directions in Orientation Distribution Functions, dubbed ODF-Fingerprinting (ODF-FP). In ODF-F…
▽ More
Diffusion tractography is routinely used to study white matter architecture and brain connectivity in vivo. A key step for successful tractography of neuronal tracts is the correct identification of tract directions in each voxel. Here we propose a fingerprinting-based methodology to identify these fiber directions in Orientation Distribution Functions, dubbed ODF-Fingerprinting (ODF-FP). In ODF-FP, fiber configurations are selected based on the similarity between measured ODFs and elements in a pre-computed library. In noisy ODFs, the library matching algorithm penalizes the more complex fiber configurations. ODF simulations and analysis of bootstrapped partial and whole-brain in vivo datasets show that the ODF-FP approach improves the detection of fiber pairs with small crossing angles while maintaining fiber direction precision, which leads to better tractography results. Rather than focusing on the ODF maxima, the ODF-FP approach uses the whole ODF shape to infer fiber directions to improve the detection of fiber bundles with small crossing angle. The resulting fiber directions aid tractography algorithms in accurately displaying neuronal tracts and calculating brain connectivity.
△ Less
Submitted 10 May, 2019;
originally announced May 2019.
-
Hybrid-State Free Precession in Nuclear Magnetic Resonance
Authors:
Jakob Assländer,
Dmitry S. Novikov,
Riccardo Lattanzi,
Daniel K. Sodickson,
Martijn A. Cloos
Abstract:
The dynamics of large spin-1/2 ensembles in the presence of a varying magnetic field are commonly described by the Bloch equation. Most magnetic field variations result in unintuitive spin dynamics, which are sensitive to small deviations in the driving field. Although simplistic field variations can produce robust dynamics, the captured information content is impoverished. Here, we identify adiab…
▽ More
The dynamics of large spin-1/2 ensembles in the presence of a varying magnetic field are commonly described by the Bloch equation. Most magnetic field variations result in unintuitive spin dynamics, which are sensitive to small deviations in the driving field. Although simplistic field variations can produce robust dynamics, the captured information content is impoverished. Here, we identify adiabaticity conditions that span a rich experiment design space with tractable dynamics. These adiabaticity conditions trap the spin dynamics in a one-dimensional subspace. Namely, the dynamics is captured by the absolute value of the magnetization, which is in a transient state, while its direction adiabatically follows the steady state. We define the hybrid state as the co-existence of these two states and identify the polar angle as the effective driving force of the spin dynamics. As an example, we optimize this drive for robust and efficient quantification of spin relaxation times and utilize it for magnetic resonance imaging of the human brain.
△ Less
Submitted 9 July, 2018;
originally announced July 2018.
-
High Impedance Detector Arrays for Magnetic Resonance
Authors:
Bei Zhang,
Daniel K. Sodickson,
Martijn A. Cloos
Abstract:
Resonant inductive coupling is commonly seen as an undesired fundamental phenomenon emergent in densely packed resonant structures, such as nuclear magnetic resonance phased array detectors. The need to mitigate coupling imposes rigid constraints on the detector design, impeding performance and limiting the scope of magnetic resonance experiments. Here we introduce a high impedance detector design…
▽ More
Resonant inductive coupling is commonly seen as an undesired fundamental phenomenon emergent in densely packed resonant structures, such as nuclear magnetic resonance phased array detectors. The need to mitigate coupling imposes rigid constraints on the detector design, impeding performance and limiting the scope of magnetic resonance experiments. Here we introduce a high impedance detector design, which can cloak itself from electrodynamic interactions with neighboring elements. We verify experimentally that the high impedance detectors do not suffer from signal-to-noise degradation mechanisms observed with traditional low impedance elements. Using this new-found robustness, we demonstrate an adaptive wearable detector array for magnetic resonance imaging of the hand. The unique properties of the detector glove reveal new pathways to study the biomechanics of soft tissues, and exemplify the enabling potential of high-impedance detectors for a wide range of demanding applications that are not well suited to traditional coil designs.
△ Less
Submitted 11 September, 2017;
originally announced September 2017.
-
Optimized Quantification of Spin Relaxation Times in the Hybrid State
Authors:
Jakob Assländer,
Riccardo Lattanzi,
Daniel K Sodickson,
Martijn A Cloos
Abstract:
Purpose: The analysis of optimized spin ensemble trajectories for relaxometry in the hybrid state.
Methods: First, we constructed visual representations to elucidate the differential equation that governs spin dynamics in hybrid state. Subsequently, numerical optimizations were performed to find spin ensemble trajectories that minimize the Cramér-Rao bound for $T_1$-encoding, $T_2$-encoding, and…
▽ More
Purpose: The analysis of optimized spin ensemble trajectories for relaxometry in the hybrid state.
Methods: First, we constructed visual representations to elucidate the differential equation that governs spin dynamics in hybrid state. Subsequently, numerical optimizations were performed to find spin ensemble trajectories that minimize the Cramér-Rao bound for $T_1$-encoding, $T_2$-encoding, and their weighted sum, respectively, followed by a comparison of the Cramér-Rao bounds obtained with our optimized spin-trajectories, as well as Look-Locker and multi-spin-echo methods. Finally, we experimentally tested our optimized spin trajectories with in vivo scans of the human brain.
Results: After a nonrecurring inversion segment on the southern hemisphere of the Bloch sphere, all optimized spin trajectories pursue repetitive loops on the northern half of the sphere in which the beginning of the first and the end of the last loop deviate from the others. The numerical results obtained in this work align well with intuitive insights gleaned directly from the governing equation. Our results suggest that hybrid-state sequences outperform traditional methods. Moreover, hybrid-state sequences that balance $T_1$- and $T_2$-encoding still result in near optimal signal-to-noise efficiency. Thus, the second parameter can be encoded at virtually no extra cost.
Conclusion: We provide insights regarding the optimal encoding processes of spin relaxation times in order to guide the design of robust and efficient pulse sequences. We find that joint acquisitions of $T_1$ and $T_2$ in the hybrid state are substantially more efficient than sequential encoding techniques.
△ Less
Submitted 2 December, 2018; v1 submitted 1 March, 2017;
originally announced March 2017.
-
Low Rank Alternating Direction Method of Multipliers Reconstruction for MR Fingerprinting
Authors:
Jakob Assländer,
Martijn A Cloos,
Florian Knoll,
Daniel K Sodickson,
Jürgen Hennig,
Riccardo Lattanzi
Abstract:
Purpose
The proposed reconstruction framework addresses the reconstruction accuracy, noise propagation and computation time for Magnetic Resonance Fingerprinting (MRF).
Methods
Based on a singular value decomposition (SVD) of the signal evolution, MRF is formulated as a low rank inverse problem in which one image is reconstructed for each singular value under consideration. This low rank app…
▽ More
Purpose
The proposed reconstruction framework addresses the reconstruction accuracy, noise propagation and computation time for Magnetic Resonance Fingerprinting (MRF).
Methods
Based on a singular value decomposition (SVD) of the signal evolution, MRF is formulated as a low rank inverse problem in which one image is reconstructed for each singular value under consideration. This low rank approximation of the signal evolution reduces the computational burden by reducing the number of Fourier transformations. Also, the low rank approximation improves the conditioning of the problem, which is further improved by extending the low rank inverse problem to an augmented Lagrangian that is solved by the alternating direction method of multipliers (ADMM). The root mean square error and the noise propagation are analyzed in simulations. For verification, in vivo examples are provided.
Results
The proposed low rank ADMM approach shows a reduced root mean square error compared to the original fingerprinting reconstruction, to a low rank approximation alone and to an ADMM approach without a low rank approximation. Incorporating sensitivity encoding allows for further artifact reduction.
Conclusion
The proposed reconstruction provides robust convergence, reduced computational burden and improved image quality compared to other MRF reconstruction approaches evaluated in this study.
△ Less
Submitted 22 November, 2016; v1 submitted 24 August, 2016;
originally announced August 2016.