Design of beam optics and radiation protection concept for the NA60+ heavy-ion experiment at CERN
Authors:
A. Gerbershagen,
C. Ahdida,
J. Bernhard,
V. Clerc,
S. Girod,
E. Scomparin,
G. Usai,
H. Vincke
Abstract:
NA60+ is a fixed target experiment proposed in the framework of the Physics Beyond Colliders programme at CERN. It aims to precisely measure the hard and electromagnetic probes in nuclear collisions. Initially proposed for the underground cavern ECN3 with very high beam intensities, the experiment now foresees a location in the EHN1 surface hall which was shown to have a limited impact on the phys…
▽ More
NA60+ is a fixed target experiment proposed in the framework of the Physics Beyond Colliders programme at CERN. It aims to precisely measure the hard and electromagnetic probes in nuclear collisions. Initially proposed for the underground cavern ECN3 with very high beam intensities, the experiment now foresees a location in the EHN1 surface hall which was shown to have a limited impact on the physics performance in spite of a significant reduction of beam intensity and detector size. The potential installation and operation of the experiment with the ion beams from the Super Proton Synchrotron (SPS) has been examined regarding detector integration, beam physics, radiation protection and shielding requirements. The integration of the experiment is considered feasible, but would require a significant reconfiguration of the existing hall infrastructure with regards to shielding and layout.
△ Less
Submitted 31 October, 2022;
originally announced October 2022.
Design development and implementation of an irradiation station at the neutron time-of-flight facility at CERN
Authors:
M. Ferrari,
D. Senajova,
O. Aberle,
Y. Aguiar,
D. Baillard,
M. Barbagallo,
A. -P. Bernardes,
L. Buonocore,
M. Cecchetto,
V. Clerc,
M. Di Castro,
R. Garcia Alia,
S. Girod,
J. -L. Grenard,
K. Kershaw,
G. Lerner,
M. Maeder,
A. Makovec,
A. Mengoni,
M. Perez Ornedo,
F. Pozzi,
C. V. Almagro,
M. Calviani
Abstract:
A new parasitic, mixed-field, neutron-dominated irradiation station has been recently commissioned at the European Laboratory for Particle Physics (CERN). The station is installed in the Neutron Time-Of-Flight (n\_TOF) facility, taking advantage of the secondary radiation produced by the neutron spallation target. The new station allows radiation damage studies to be performed in irradiation condi…
▽ More
A new parasitic, mixed-field, neutron-dominated irradiation station has been recently commissioned at the European Laboratory for Particle Physics (CERN). The station is installed in the Neutron Time-Of-Flight (n\_TOF) facility, taking advantage of the secondary radiation produced by the neutron spallation target. The new station allows radiation damage studies to be performed in irradiation conditions that are closer to the ones encountered during the operation of particle accelerators; the irradiation tests carried out in the station will be complementary to the standard tests on materials, usually performed with gamma sources. Samples will be exposed to neutron doses in the MGy range per year, with minimal impact on the n TOF facility operation. The station has twenty-four irradiation positions, each hosting up to 100 cm3 of sample material. In view of its proximity to the n\_TOF target, inside protective shielding, the irradiation station and its operating procedures have been carefully developed taking into account the safety of personnel and to avoid any unwanted impact on the operation of the n\_TOF facility and experiments. Due to the residual radioactivity of the whole area around the n\_TOF target and of the irradiated samples, access to the irradiation station is forbidden to human operators even when the n\_TOF facility is not in operation. Robots are used for the remote installation and retrieval of the samples, and other optimizations of the handling procedures were developed in compliance with radiation protection regulations and the aim of minimizing doses to personnel.
△ Less
Submitted 18 June, 2022; v1 submitted 25 February, 2022;
originally announced February 2022.
Upgrade of the Two-Screen Measurement Setup in the AWAKE Experiment
Authors:
M. Turner,
V. Clerc,
I. Gorgisyan,
E. Gschwendtner,
S. Mazzoni,
A. Petrenko
Abstract:
The AWAKE project at CERN uses a self-modulated \SI{400}{GeV/c} proton bunch to drive GV/m wakefields in a \SI{10}{m} long plasma with an electron density of $n_{pe} = 7 \times 10^{14}\,\rm{electrons/cm}^3$. We present the upgrade of a proton beam diagnostic to indirectly prove that the bunch self-modulated by imaging defocused protons with two screens downstream the end of the plasma. The two-scr…
▽ More
The AWAKE project at CERN uses a self-modulated \SI{400}{GeV/c} proton bunch to drive GV/m wakefields in a \SI{10}{m} long plasma with an electron density of $n_{pe} = 7 \times 10^{14}\,\rm{electrons/cm}^3$. We present the upgrade of a proton beam diagnostic to indirectly prove that the bunch self-modulated by imaging defocused protons with two screens downstream the end of the plasma. The two-screen diagnostic has been installed, commissioned and tested in autumn 2016 and limitations were identified. We plan to install an upgraded diagnostics to overcome these limitations.
△ Less
Submitted 3 October, 2018;
originally announced October 2018.