-
Hanbury Brown and Twiss interference of electrons in free space from independent needle tip sources
Authors:
Anton Classen,
Raul Corrêa,
Florian Fleischmann,
Simon Semmler,
Marc-Oliver Pleinert,
Peter Hommelhoff,
Joachim von Zanthier
Abstract:
We investigate two-electron interference in free space using two laser-triggered needle tips as independent electron sources, a fermionic realisation of the landmark Hanbury Brown and Twiss interferometer. We calculate the two-electron interference pattern in a quantum path formalism taking into account the fermionic nature and the spin configuration of the electrons. We also estimate the Coulomb…
▽ More
We investigate two-electron interference in free space using two laser-triggered needle tips as independent electron sources, a fermionic realisation of the landmark Hanbury Brown and Twiss interferometer. We calculate the two-electron interference pattern in a quantum path formalism taking into account the fermionic nature and the spin configuration of the electrons. We also estimate the Coulomb repulsion in the setup in a semiclassical approach. We find that antibunching resulting from Pauli's exclusion principle and repulsion stemming from the Coulomb interaction can be clearly distinguished.
△ Less
Submitted 30 January, 2024;
originally announced January 2024.
-
An Interpretable Machine Learning Model with Deep Learning-based Imaging Biomarkers for Diagnosis of Alzheimer's Disease
Authors:
Wenjie Kang,
Bo Li,
Janne M. Papma,
Lize C. Jiskoot,
Peter Paul De Deyn,
Geert Jan Biessels,
Jurgen A. H. R. Claassen,
Huub A. M. Middelkoop,
Wiesje M. van der Flier,
Inez H. G. B. Ramakers,
Stefan Klein,
Esther E. Bron
Abstract:
Machine learning methods have shown large potential for the automatic early diagnosis of Alzheimer's Disease (AD). However, some machine learning methods based on imaging data have poor interpretability because it is usually unclear how they make their decisions. Explainable Boosting Machines (EBMs) are interpretable machine learning models based on the statistical framework of generalized additiv…
▽ More
Machine learning methods have shown large potential for the automatic early diagnosis of Alzheimer's Disease (AD). However, some machine learning methods based on imaging data have poor interpretability because it is usually unclear how they make their decisions. Explainable Boosting Machines (EBMs) are interpretable machine learning models based on the statistical framework of generalized additive modeling, but have so far only been used for tabular data. Therefore, we propose a framework that combines the strength of EBM with high-dimensional imaging data using deep learning-based feature extraction. The proposed framework is interpretable because it provides the importance of each feature. We validated the proposed framework on the Alzheimer's Disease Neuroimaging Initiative (ADNI) dataset, achieving accuracy of 0.883 and area-under-the-curve (AUC) of 0.970 on AD and control classification. Furthermore, we validated the proposed framework on an external testing set, achieving accuracy of 0.778 and AUC of 0.887 on AD and subjective cognitive decline (SCD) classification. The proposed framework significantly outperformed an EBM model using volume biomarkers instead of deep learning-based features, as well as an end-to-end convolutional neural network (CNN) with optimized architecture.
△ Less
Submitted 15 August, 2023;
originally announced August 2023.
-
Analysis of intensity correlation enhanced plasmonic structured illumination microscopy
Authors:
Anton Classen,
Xinghua Liu,
Aleksei M. Zheltikov,
Girish S. Agarwal
Abstract:
We propose to enhance the performance of localized plasmon structured illumination microscopy (LP-SIM) via intensity correlations. LP-SIM uses sub-wavelength illumination patterns to encode high spatial frequency information. It can enhance the resolution up to three-fold before gaps in the OTF support arise. For blinking fluorophores or for quantum antibunching an intensity correlation analysis i…
▽ More
We propose to enhance the performance of localized plasmon structured illumination microscopy (LP-SIM) via intensity correlations. LP-SIM uses sub-wavelength illumination patterns to encode high spatial frequency information. It can enhance the resolution up to three-fold before gaps in the OTF support arise. For blinking fluorophores or for quantum antibunching an intensity correlation analysis induces higher harmonics of the illumination pattern and enlarges the effective OTF. This enables ultrahigh resolutions without gaps in the OTF support, and thus a fully deterministic imaging scheme. We present simulations that include shot and external noise and demonstrate the resolution power under realistic photon budgets. The technique has potential in light microscopy where low-intensity illumination is paramount while aiming for high spatial but moderate temporal resolutions.
△ Less
Submitted 18 March, 2021;
originally announced March 2021.
-
Cross-Cohort Generalizability of Deep and Conventional Machine Learning for MRI-based Diagnosis and Prediction of Alzheimer's Disease
Authors:
Esther E. Bron,
Stefan Klein,
Janne M. Papma,
Lize C. Jiskoot,
Vikram Venkatraghavan,
Jara Linders,
Pauline Aalten,
Peter Paul De Deyn,
Geert Jan Biessels,
Jurgen A. H. R. Claassen,
Huub A. M. Middelkoop,
Marion Smits,
Wiro J. Niessen,
John C. van Swieten,
Wiesje M. van der Flier,
Inez H. G. B. Ramakers,
Aad van der Lugt
Abstract:
This work validates the generalizability of MRI-based classification of Alzheimer's disease (AD) patients and controls (CN) to an external data set and to the task of prediction of conversion to AD in individuals with mild cognitive impairment (MCI). We used a conventional support vector machine (SVM) and a deep convolutional neural network (CNN) approach based on structural MRI scans that underwe…
▽ More
This work validates the generalizability of MRI-based classification of Alzheimer's disease (AD) patients and controls (CN) to an external data set and to the task of prediction of conversion to AD in individuals with mild cognitive impairment (MCI). We used a conventional support vector machine (SVM) and a deep convolutional neural network (CNN) approach based on structural MRI scans that underwent either minimal pre-processing or more extensive pre-processing into modulated gray matter (GM) maps. Classifiers were optimized and evaluated using cross-validation in the ADNI (334 AD, 520 CN). Trained classifiers were subsequently applied to predict conversion to AD in ADNI MCI patients (231 converters, 628 non-converters) and in the independent Health-RI Parelsnoer data set. From this multi-center study representing a tertiary memory clinic population, we included 199 AD patients, 139 participants with subjective cognitive decline, 48 MCI patients converting to dementia, and 91 MCI patients who did not convert to dementia. AD-CN classification based on modulated GM maps resulted in a similar AUC for SVM (0.940) and CNN (0.933). Application to conversion prediction in MCI yielded significantly higher performance for SVM (0.756) than for CNN (0.742). In external validation, performance was slightly decreased. For AD-CN, it again gave similar AUCs for SVM (0.896) and CNN (0.876). For prediction in MCI, performances decreased for both SVM (0.665) and CNN (0.702). Both with SVM and CNN, classification based on modulated GM maps significantly outperformed classification based on minimally processed images. Deep and conventional classifiers performed equally well for AD classification and their performance decreased only slightly when applied to the external cohort. We expect that this work on external validation contributes towards translation of machine learning to clinical practice.
△ Less
Submitted 26 May, 2021; v1 submitted 16 December, 2020;
originally announced December 2020.
-
Partial Coherence in modern optics: Emil Wolf's legacy in the 21st century
Authors:
Girish S. Agarwal,
Anton Classen
Abstract:
We highlight the impact of Emil Wolf's work on coherence and polarization on an ever increasing amount of applications in the 21 st century. We present a brief review of how partial coherence at the level of increasing order of coherence functions is leading to evolution in the better methods for microscopy, imaging, optical coherence tomography; speckle imaging; propagation through random media.…
▽ More
We highlight the impact of Emil Wolf's work on coherence and polarization on an ever increasing amount of applications in the 21 st century. We present a brief review of how partial coherence at the level of increasing order of coherence functions is leading to evolution in the better methods for microscopy, imaging, optical coherence tomography; speckle imaging; propagation through random media. This evolution in our capabilities is expected to have wide ramifications in Science and Engineering.
△ Less
Submitted 15 January, 2020;
originally announced January 2020.
-
Squeezed Light Induced Two-photon Absorption Fluorescence of Fluorescein Biomarkers
Authors:
Tian Li,
Fu Li,
Charles Altuzarra,
Anton Classen,
Girish S. Agarwal
Abstract:
Two-photon absorption (TPA) fluorescence of biomarkers has been decisive in advancing the fields of biosensing and deep-tissue in vivo imaging of live specimens. However, due to the extremely small TPA cross section and the quadratic dependence on the input photon flux, extremely high peak-intensity pulsed lasers are imperative, which can result in significant photo- and thermal-damage. Previous w…
▽ More
Two-photon absorption (TPA) fluorescence of biomarkers has been decisive in advancing the fields of biosensing and deep-tissue in vivo imaging of live specimens. However, due to the extremely small TPA cross section and the quadratic dependence on the input photon flux, extremely high peak-intensity pulsed lasers are imperative, which can result in significant photo- and thermal-damage. Previous works on entangled TPA (ETPA) with spontaneous parametric down-conversion (SPDC) light sources found a linear dependence on the input photon-pair flux, but are limited by low optical powers, along with a very broad spectrum. We report that by using a high-flux squeezed light source for TPA, a fluorescence enhancement of 47 is achieved in fluorescein biomarkers as compared to classical TPA. Moreover, a polynomial behavior of the TPA rate is observed in the DCM laser dye.
△ Less
Submitted 23 June, 2020; v1 submitted 22 November, 2019;
originally announced November 2019.
-
Ghost Imaging at an XUV Free-Electron Laser
Authors:
Young Yong Kim,
Luca Gelisio,
Giuseppe Mercurio,
Siarhei Dziarzhytski,
Martin Beye,
Lars Bocklage,
Anton Classen,
Christian David,
Oleg Yu. Gorobtsov,
Ruslan Khubbutdinov,
Sergey Lazarev,
Nastasia Mukharamova,
Yury N. Obukhov,
Benedikt Roesner,
Kai Schlage,
Ivan A. Zaluzhnyy,
Guenter Brenner,
Ralf Roehlsberger,
Joachim von Zanthier,
Wilfried Wurth,
Ivan A. Vartanyants
Abstract:
Radiation damage is one of the most severe resolution limiting factors in x-ray imaging, especially relevant to biological samples. One way of circumventing this problem is to exploit correlation-based methods developed in quantum imaging. Among these, there is ghost imaging (GI) in which the image is formed by radiation that has never interacted with the sample. Here, we demonstrate GI at an XUV…
▽ More
Radiation damage is one of the most severe resolution limiting factors in x-ray imaging, especially relevant to biological samples. One way of circumventing this problem is to exploit correlation-based methods developed in quantum imaging. Among these, there is ghost imaging (GI) in which the image is formed by radiation that has never interacted with the sample. Here, we demonstrate GI at an XUV free-electron laser by utilizing correlation techniques. We discuss the experimental challenges, optimal setup, and crucial ingredients to maximize the achievable resolution.
△ Less
Submitted 16 November, 2018;
originally announced November 2018.
-
Generation of N00N-like interferences with two thermal light sources
Authors:
Daniel Bhatti,
Anton Classen,
Raimund Schneider,
Steffen Oppel,
Joachim von Zanthier
Abstract:
Measuring the $M$th-order intensity correlation function of light emitted by two statistically independent thermal light sources may display N00N-like interferences of arbitrary order $N = M/2$. We show that via a particular choice of detector positions one can isolate $M$-photon quantum paths where either all $M$ photons are emitted from the same source or $M/2$ photons are collectively emitted b…
▽ More
Measuring the $M$th-order intensity correlation function of light emitted by two statistically independent thermal light sources may display N00N-like interferences of arbitrary order $N = M/2$. We show that via a particular choice of detector positions one can isolate $M$-photon quantum paths where either all $M$ photons are emitted from the same source or $M/2$ photons are collectively emitted by both sources. The latter superposition displays N00N-like oscillations with $N = M/2$ which may serve, e.g., in astronomy, for imaging two distant thermal sources with $M/2$-fold increased resolution. We also discuss slightly modified detection schemes improving the visibility of the N00N-like interference pattern and present measurements verifying the theoretical predictions.
△ Less
Submitted 25 September, 2018;
originally announced September 2018.
-
Analysis of superresolution via 3D structured illumination intensity correlation microscopy
Authors:
Anton Classen,
Joachim von Zanthier,
Girish S. Agarwal
Abstract:
Intensity correlation microscopy (ICM), which is prominently known through antibunching microscopy or super-resolution optical fluctuation imaging (SOFI), provides superresolution through a correlation analysis of antibunching of independent quantum emitters or temporal fluctuations of blinking fluorophores. For correlation order $m$ the PSF in the signal is effectively taken to the $m$th power, a…
▽ More
Intensity correlation microscopy (ICM), which is prominently known through antibunching microscopy or super-resolution optical fluctuation imaging (SOFI), provides superresolution through a correlation analysis of antibunching of independent quantum emitters or temporal fluctuations of blinking fluorophores. For correlation order $m$ the PSF in the signal is effectively taken to the $m$th power, and is thus directly shrunk by the factor $\sqrt{m}$. Combined with deconvolution a close to linear resolution improvement of factor $m$ can be obtained. Yet, analysis of high correlation orders is challenging, what limits the achievable resolutions. Here we propose to use three dimensional structured illumination along with $m$th-order correlation analysis to obtain an enhanced scaling of up to $m+m=2m$. Including the stokes shift or plasmonic sub-wavelength illumination enhancements beyond $2m$ can be achieved. Hence, resolutions far below the diffraction limit in full 3D imaging can potentially be achieved already with low correlation orders. Since ICM operates in the linear regime our approach may be particularly promising for enhancing the resolution in biological imaging at low illumination levels.
△ Less
Submitted 5 October, 2018; v1 submitted 2 June, 2018;
originally announced June 2018.
-
Quantum Imaging with Incoherently Scattered Light from a Free-Electron Laser
Authors:
Raimund Schneider,
Thomas Mehringer,
Giuseppe Mercurio,
Lukas Wenthaus,
Anton Classen,
Günter Brenner,
Oleg Gorobtsov,
Adrian Benz,
Daniel Bhatti,
Lars Bocklage,
Birgit Fischer,
Sergey Lazarev,
Yuri Obukhov,
Kai Schlage,
Petr Skopintsev,
Jochen Wagner,
Felix Waldmann,
Svenja Willing,
Ivan Zaluzhnyy,
Wilfried Wurth,
Ivan A. Vartanyants,
Ralf Röhlsberger,
Joachim von Zanthier
Abstract:
The advent of accelerator-driven free-electron lasers (FEL) has opened new avenues for high-resolution structure determination via diffraction methods that go far beyond conventional x-ray crystallography methods. These techniques rely on coherent scattering processes that require the maintenance of first-order coherence of the radiation field throughout the imaging procedure. Here we show that hi…
▽ More
The advent of accelerator-driven free-electron lasers (FEL) has opened new avenues for high-resolution structure determination via diffraction methods that go far beyond conventional x-ray crystallography methods. These techniques rely on coherent scattering processes that require the maintenance of first-order coherence of the radiation field throughout the imaging procedure. Here we show that higher-order degrees of coherence, displayed in the intensity correlations of incoherently scattered x-rays from an FEL, can be used to image two-dimensional objects with a spatial resolution close to or even below the Abbe limit. This constitutes a new approach towards structure determination based on incoherent processes, including Compton scattering, fluorescence emission or wavefront distortions, generally considered detrimental for imaging applications. Our method is an extension of the landmark intensity correlation measurements of Hanbury Brown and Twiss to higher than second-order paving the way towards determination of structure and dynamics of matter in regimes where coherent imaging methods have intrinsic limitations.
△ Less
Submitted 2 October, 2017;
originally announced October 2017.
-
Incoherent Diffractive Imaging via Intensity Correlations of hard X-rays
Authors:
Anton Classen,
Kartik Ayyer,
Henry N. Chapman,
Ralf Röhlsberger,
Joachim von Zanthier
Abstract:
Established x-ray diffraction methods allow for high-resolution structure determination of crystals, crystallized protein structures or even single molecules. While these techniques rely on coherent scattering, incoherent processes like Compton scattering or fluorescence emission -- often the predominant scattering mechanisms -- are generally considered detrimental for imaging applications. Here w…
▽ More
Established x-ray diffraction methods allow for high-resolution structure determination of crystals, crystallized protein structures or even single molecules. While these techniques rely on coherent scattering, incoherent processes like Compton scattering or fluorescence emission -- often the predominant scattering mechanisms -- are generally considered detrimental for imaging applications. Here we show that intensity correlations of incoherently scattered x-ray radiation can be used to image the full 3D structure of the scattering atoms with significantly higher resolution compared to conventional coherent diffraction imaging and crystallography, including additional three-dimensional information in Fourier space for a single sample orientation. We present a number of properties of incoherent diffractive imaging that are conceptually superior to those of coherent methods.
△ Less
Submitted 24 May, 2017;
originally announced May 2017.
-
Superresolution via Structured Illumination Quantum Correlation Microscopy (SIQCM)
Authors:
Anton Classen,
Joachim von Zanthier,
Marlan O. Scully,
Girish S. Agarwal
Abstract:
We propose to use intensity correlation microscopy in combination with structured illumination to image quantum emitters that exhibit antibunching with a spatial resolution reaching far beyond the Rayleigh limit. Combining intensity measurements and intensity auto correlations up to order $m$ creates an effective PSF with FWHM shrunk by the factor $\sqrt{m}$. Structured Illumination microscopy on…
▽ More
We propose to use intensity correlation microscopy in combination with structured illumination to image quantum emitters that exhibit antibunching with a spatial resolution reaching far beyond the Rayleigh limit. Combining intensity measurements and intensity auto correlations up to order $m$ creates an effective PSF with FWHM shrunk by the factor $\sqrt{m}$. Structured Illumination microscopy on the other hand introduces a resolution improvement of factor 2 by use of the principle of moiré fringes. Here, we show that for linear low-intensity excitation and linear optical detection the simultaneous use of both techniques leads to an in theory unlimited resolution power with the improvement scaling favorably as $m + \sqrt{m}$ in dependence of the correlation order $m$. Hence, yielding this technique to be of interest in microscopy for imaging a variety of samples including biological ones. We present the underlying theory and simulations demonstrating the highly increased spatial superresolution, and point out requirements for an experimental implementation.
△ Less
Submitted 14 February, 2017;
originally announced February 2017.
-
Superresolving Imaging of Irregular Arrays of Thermal Light Sources using Multiphoton Interferences
Authors:
Anton Classen,
Felix Waldmann,
Sebastian Giebel,
Raimund Schneider,
Daniel Bhatti,
Thomas Mehringer,
Joachim von Zanthier
Abstract:
We propose to use multiphoton interferences of photons emitted from statistically independent thermal light sources in combination with linear optical detection techniques to reconstruct, i.e., image, arbitrary source geometries in one dimension with subclassical resolution. The scheme is an extension of earlier work [Phys. Rev. Lett. 109, 233603 (2012)] where N regularly spaced sources in one dim…
▽ More
We propose to use multiphoton interferences of photons emitted from statistically independent thermal light sources in combination with linear optical detection techniques to reconstruct, i.e., image, arbitrary source geometries in one dimension with subclassical resolution. The scheme is an extension of earlier work [Phys. Rev. Lett. 109, 233603 (2012)] where N regularly spaced sources in one dimension were imaged by use of the Nth-order intensity correlation function. Here, we generalize the scheme to reconstruct any number of independent thermal light sources at arbitrary separations in one dimension exploiting intensity correlation functions of order $m \geq 3$. We present experimental results confirming the imaging protocol and provide a rigorous mathematical proof for the obtained subclassical resolution.
△ Less
Submitted 10 August, 2016;
originally announced August 2016.
-
Thermal x-ray diffraction and near-field phase contrast imaging
Authors:
Zheng Li,
Anton Classen,
Tao Peng,
Nikita Medvedev,
Fenglin Wang,
Henry N. Chapman,
Yanhua Shih
Abstract:
Using higher-order coherence of thermal light sources, the resolution power of standard x-ray imaging techniques can be enhanced. In this work, we applied the higher-order measurement to far-field x-ray diffraction and near-field phase contrast imaging (PCI), in order to achieve superresolution in x-ray diffraction and obtain enhanced intensity contrast in PCI. The cost of implementing such scheme…
▽ More
Using higher-order coherence of thermal light sources, the resolution power of standard x-ray imaging techniques can be enhanced. In this work, we applied the higher-order measurement to far-field x-ray diffraction and near-field phase contrast imaging (PCI), in order to achieve superresolution in x-ray diffraction and obtain enhanced intensity contrast in PCI. The cost of implementing such schemes is minimal compared to the methods that achieve similar effects by using entangled x-ray photon pairs.
△ Less
Submitted 14 February, 2018; v1 submitted 10 June, 2016;
originally announced June 2016.