Acceleration of a Positron Bunch in a Hollow Channel Plasma
Authors:
Spencer Gessner,
Erik Adli,
James M. Allen,
Weiming An,
Christine I. Clarke,
Chris E. Clayton,
Sebastien Corde,
Antoine Doche,
Joel Frederico,
Selina Z. Green,
Mark J. Hogan,
Chan Joshi,
Carl A. Lindstrom,
Michael Litos,
Kenneth A. Marsh,
Warren B. Mori,
Brendan O'Shea,
Navid Vafaei-Najafabadi,
Vitaly Yakimenko
Abstract:
Plasmas are a compelling medium for particle acceleration owing to their natural ability to sustain electric fields that are orders of magnitude larger than those available in conventional radio-frequency accelerators. Plasmas are also unique amongst accelerator technologies in that they respond differently to beams of opposite charge. The asymmetric response of a plasma to highly-relativistic ele…
▽ More
Plasmas are a compelling medium for particle acceleration owing to their natural ability to sustain electric fields that are orders of magnitude larger than those available in conventional radio-frequency accelerators. Plasmas are also unique amongst accelerator technologies in that they respond differently to beams of opposite charge. The asymmetric response of a plasma to highly-relativistic electron and positron beams arises from the fact that plasmas are composed of light, mobile electrons and heavy, stationary ions. Hollow channel plasma acceleration is a technique for symmetrizing the response of the plasma, such that it works equally well for high-energy electron and positron beams. In the experiment described here, we demonstrate the generation of a positron beam-driven wake in an extended, annular plasma channel, and acceleration of a second trailing witness positron bunch by the wake. The leading bunch excites the plasma wakefield and loses energy to the plasma, while the witness bunch experiences an accelerating field and gains energy, thus providing a proof-of-concept for hollow channel acceleration of positron beams. At a bunch separation of 330 um, the accelerating gradient is 70 MV/m, the transformer ratio is 0.55, and the energy transfer efficiency is 18% for a drive-to-witness beam charge ratio of 5:1.
△ Less
Submitted 30 December, 2023; v1 submitted 4 April, 2023;
originally announced April 2023.
-
Plasma-photonic spatiotemporal synchronization of relativistic electron and laser beams
Authors:
Paul Scherkl,
Alexander Knetsch,
Thomas Heinemann,
Andrew Sutherland,
Ahmad Fahim Habib,
Oliver Karger,
Daniel Ullmann,
Andrew Beaton,
Gavin Kirwan,
Grace Manahan,
Yunfeng Xi,
Aihua Deng,
Michael Dennis Litos,
Brendan D. OShea,
Selina Z. Green,
Christine I. Clarke,
Gerard Andonian,
Ralph Assmann,
Dino A. Jaroszynski,
David L. Bruhwiler,
Jonathan Smith,
John R. Cary,
Mark J. Hogan,
Vitaly Yakimenko,
James B. Rosenzweig
, et al. (1 additional authors not shown)
Abstract:
Modern particle accelerators and their applications increasingly rely on precisely coordinated interactions of intense charged particle and laser beams. Femtosecond-scale synchronization alongside micrometre-scale spatial precision are essential e.g. for pump-probe experiments, seeding and diagnostics of advanced light sources and for plasma-based accelerators. State-of-the-art temporal or spatial…
▽ More
Modern particle accelerators and their applications increasingly rely on precisely coordinated interactions of intense charged particle and laser beams. Femtosecond-scale synchronization alongside micrometre-scale spatial precision are essential e.g. for pump-probe experiments, seeding and diagnostics of advanced light sources and for plasma-based accelerators. State-of-the-art temporal or spatial diagnostics typically operate with low-intensity beams to avoid material damage at high intensity. As such, we present a plasma-based approach, which allows measurement of both temporal and spatial overlap of high-intensity beams directly at their interaction point. It exploits amplification of plasma afterglow arising from the passage of an electron beam through a laser-generated plasma filament. The corresponding photon yield carries the spatiotemporal signature of the femtosecond-scale dynamics, yet can be observed as a visible light signal on microsecond-millimetre scales.
△ Less
Submitted 25 August, 2019;
originally announced August 2019.
-
Electron bunch generation from a plasma photocathode
Authors:
Aihua Deng,
Oliver Karger,
Thomas Heinemann,
Alexander Knetsch,
Paul Scherkl,
Grace Gloria Manahan,
Andrew Beaton,
Daniel Ullmann,
Gregor Wittig,
Ahmad Fahim Habib,
Yunfeng Xi,
Mike Dennis Litos,
Brendan D. O'Shea,
Spencer Gessner,
Christine I. Clarke,
Selina Z. Green,
Carl Andreas Lindstrøm,
Erik Adli,
Rafal Zgadzaj,
Mike C. Downer,
Gerard Andonian,
Alex Murokh,
David Leslie Bruhwiler,
John R. Cary,
Mark J. Hogan
, et al. (3 additional authors not shown)
Abstract:
Plasma waves generated in the wake of intense, relativistic laser or particle beams can accelerate electron bunches to giga-electronvolt (GeV) energies in centimetre-scale distances. This allows the realization of compact accelerators having emerging applications, ranging from modern light sources such as the free-electron laser (FEL) to energy frontier lepton colliders. In a plasma wakefield acce…
▽ More
Plasma waves generated in the wake of intense, relativistic laser or particle beams can accelerate electron bunches to giga-electronvolt (GeV) energies in centimetre-scale distances. This allows the realization of compact accelerators having emerging applications, ranging from modern light sources such as the free-electron laser (FEL) to energy frontier lepton colliders. In a plasma wakefield accelerator, such multi-gigavolt-per-metre (GV m$^{-1}$) wakefields can accelerate witness electron bunches that are either externally injected or captured from the background plasma. Here we demonstrate optically triggered injection and acceleration of electron bunches, generated in a multi-component hydrogen and helium plasma employing a spatially aligned and synchronized laser pulse. This ''plasma photocathode'' decouples injection from wake excitation by liberating tunnel-ionized helium electrons directly inside the plasma cavity, where these cold electrons are then rapidly boosted to relativistic velocities. The injection regime can be accessed via optical density down-ramp injection, is highly tunable and paves the way to generation of electron beams with unprecedented low transverse emittance, high current and 6D-brightness. This experimental path opens numerous prospects for transformative plasma wakefield accelerator applications based on ultra-high brightness beams.
△ Less
Submitted 1 July, 2019;
originally announced July 2019.
-
Measurement of transverse wakefields induced by a misaligned positron bunch in a hollow channel plasma accelerator
Authors:
C. A. Lindstrøm,
E. Adli,
J. M. Allen,
W. An,
C. Beekman,
C. I. Clarke,
C. E. Clayton,
S. Corde,
A. Doche,
J. Frederico,
S. J. Gessner,
S. Z. Green,
M. J. Hogan,
C. Joshi,
M. Litos,
W. Lu,
K. A. Marsh,
W. B. Mori,
B. D. O'Shea,
N. Vafaei-Najafabadi,
V. Yakimenko
Abstract:
Hollow channel plasma wakefield acceleration is a proposed method to provide high acceleration gradients for electrons and positrons alike: a key to future lepton colliders. However, beams which are misaligned from the channel axis induce strong transverse wakefields, deflecting beams and reducing the collider luminosity. This undesirable consequence sets a tight constraint on the alignment accura…
▽ More
Hollow channel plasma wakefield acceleration is a proposed method to provide high acceleration gradients for electrons and positrons alike: a key to future lepton colliders. However, beams which are misaligned from the channel axis induce strong transverse wakefields, deflecting beams and reducing the collider luminosity. This undesirable consequence sets a tight constraint on the alignment accuracy of the beam propagating through the channel. Direct measurements of beam misalignment-induced transverse wakefields are therefore essential for designing mitigation strategies. We present the first quantitative measurements of transverse wakefields in a hollow plasma channel, induced by an off-axis 20 GeV positron bunch, and measured with another 20 GeV lower charge trailing positron probe bunch. The measurements are largely consistent with theory.
△ Less
Submitted 25 February, 2018;
originally announced February 2018.
-
9 GeV Energy Gain in a Beam-Driven Plasma Wakefield Accelerator
Authors:
M Litos,
E Adli,
J M Allen,
W An,
C I Clarke,
S Corde,
C E Clayton,
J Frederico,
S J Gessner,
S Z Green,
M J Hogan,
C Joshi,
W. Lu,
K A Marsh,
W B Mori,
M Schmeltz,
N Vafaei-Najafabadi,
V Yakimenko
Abstract:
An electron beam has gained a maximum energy of 9 GeV per particle in a 1.3 m-long electron beam-driven plasma wakefield accelerator. The amount of charge accelerated in the spectral peak was 28.3 pC, and the root-mean-square energy spread was 5.0%. The mean accelerated charge and energy gain per particle of the 215 shot data set was 115 pC and 5.3 GeV, respectively, corresponding to an accelerati…
▽ More
An electron beam has gained a maximum energy of 9 GeV per particle in a 1.3 m-long electron beam-driven plasma wakefield accelerator. The amount of charge accelerated in the spectral peak was 28.3 pC, and the root-mean-square energy spread was 5.0%. The mean accelerated charge and energy gain per particle of the 215 shot data set was 115 pC and 5.3 GeV, respectively, corresponding to an acceleration gradient of 4.0 GeV/m at the spectral peak. The mean energy spread of the data set was 5.1%. These results are consistent with the extrapolation of the previously reported energy gain results using a shorter, 36 cm-long plasma source to within 10%, evincing a non-evolving wake structure that can propagate distances of over a meter in length. Wake-loading effects were evident in the data through strong dependencies observed between various spectral properties and the amount of accelerated charge.
△ Less
Submitted 20 November, 2015;
originally announced November 2015.
-
Evidence for high-energy and low-emittance electron beams using ionization injection of charge in a plasma wakefield accelerator
Authors:
N. Vafaei-Najafabadi,
W. An,
C. E. Clayton,
C. Joshi,
K. A. Marsh,
W. B. Mori,
E. C. Welch,
W. Lu,
E. Adli,
J. Allen,
C. I. Clarke,
S. Corde,
J. Frederico,
S. J. Gessner,
S. Z. Green,
M. J. Hogan,
M. D. Litos,
V. Yakimenko
Abstract:
Ionization injection in a plasma wakefield accelerator was investigated experimentally using two lithium plasma sources of different lengths. The ionization of the helium gas, used to confine the lithium, injects electrons in the wake. After acceleration, these injected electrons were observed as a distinct group from the drive beam on the energy spectrometer. They typically have a charge of tens…
▽ More
Ionization injection in a plasma wakefield accelerator was investigated experimentally using two lithium plasma sources of different lengths. The ionization of the helium gas, used to confine the lithium, injects electrons in the wake. After acceleration, these injected electrons were observed as a distinct group from the drive beam on the energy spectrometer. They typically have a charge of tens of pC, an energy spread of a few GeV, and a maximum energy of up to 30 GeV. The emittance of this group of electrons can be many times smaller than the initial emittance of the drive beam. The energy scaling for the trapped charge from one plasma length to the other is consistent with the blowout theory of the plasma wakefield.
△ Less
Submitted 5 October, 2015;
originally announced October 2015.
-
Resolution of Longitudinal Profile Measures using Coherent Smith-Purcell Radiation with the Number of Gratings and the Number of Pulses Used
Authors:
Mélissa Vieille Grosjean,
Joanna Barros,
Nicolas Delerue,
Faissal Bakkali Taheri,
George Doucas,
Ivan Vasilyevich Konoplev,
Armin Reichold,
Christine Isabel Clarke
Abstract:
The E-203 collaboration is testing a device on FACET at SLAC to measure the longitudinal profile of electron bunches using Smith-Purcell radiation. At FACET the electron bunches have an energy of 20~GeV and a duration of a few hundred femtoseconds. Smith-Purcell radiation is emitted when a charged particle passes close to the surface of a metallic grating. We have studied the stability of the meas…
▽ More
The E-203 collaboration is testing a device on FACET at SLAC to measure the longitudinal profile of electron bunches using Smith-Purcell radiation. At FACET the electron bunches have an energy of 20~GeV and a duration of a few hundred femtoseconds. Smith-Purcell radiation is emitted when a charged particle passes close to the surface of a metallic grating. We have studied the stability of the measurement from pulse to pulse and the resolution of the measure depending on the number of gratings used.
△ Less
Submitted 30 July, 2014;
originally announced July 2014.
-
Proposal for Single-Bunch Collimator Wakefield Measurements at SLAC ESTB
Authors:
J. Resta-Lopez,
C. I. Clarke,
A. Faus-Golfe,
N. Fuster-Martinez,
C. Hast,
R. M. Jones,
A. Latina,
M. Pivi,
G. Rumolo,
D. Schulte,
J. Smith,
R. Tomas
Abstract:
Collimator wakefields in the Beam Delivery System (BDS) of future linear colliders, such as the International Linear Collider (ILC) and the Compact Linear Collider (CLIC), can be an important source of emittance growth and beam jitter amplification, consequently degrading the luminosity. Therefore, a better understanding of collimator wakefield effects is essential to optimise the collimation syst…
▽ More
Collimator wakefields in the Beam Delivery System (BDS) of future linear colliders, such as the International Linear Collider (ILC) and the Compact Linear Collider (CLIC), can be an important source of emittance growth and beam jitter amplification, consequently degrading the luminosity. Therefore, a better understanding of collimator wakefield effects is essential to optimise the collimation systems of future linear colliders in order to minimise wakefield effects. In the past, measurements of single-bunch collimator wakefields have been carried out at SLAC with the aim of benchmarking theory, numerical calculations and experiments. Those studies revealed some discrepancies between the measurements and the theoretical models. New experimental tests using available beam test facilities, such as the End Station A Test Beam (ESTB) at SLAC, would help to improve our understanding on collimator wakefields. ESTB will provide the perfect test bed to investigate collimator wakefields for different bunch length conditions, relevant for both ILC (300 micrometers nominal bunch length) and CLIC (44 micrometers nominal bunch length) studies. Here we propose to perform new experimental tests of collimator wakefield effects on electron/positron beams at SLAC ESTB.
△ Less
Submitted 25 December, 2012;
originally announced December 2012.