Skip to main content

Showing 1–19 of 19 results for author: Citterio, O

.
  1. Profile reconstruction of grazing-incidence X-ray mirrors from intra-focal X-ray full imaging

    Authors: D. Spiga, S. Basso, M. Bavdaz, V. Burwitz, M. Civitani, O. Citterio, M. Ghigo, G. Hartner, B. Menz, G. Pareschi, L. Proserpio, B. Salmaso, G. Tagliaferri, E. Wille

    Abstract: The optics of a number of future X-ray telescopes will have very long focal lengths (10 - 20 m), and will consist of a number of nested/stacked thin, grazing-incidence mirrors. The optical quality characterization of a real mirror can be obtained via profile metrology, and the Point Spread Function of the mirror can be derived via one of the standard computation methods. However, in practical case… ▽ More

    Submitted 8 September, 2015; originally announced September 2015.

    Journal ref: Proceedings of the SPIE, Optics for EUV, X-Ray, and Gamma-Ray Astronomy VI, Vol. 8861, 88611F (2013)

  2. The imaging properties of the Gas Pixel Detector as a focal plane polarimeter

    Authors: S. Fabiani, E. Costa, E. Del Monte, F. Muleri, P. Soffitta, A. Rubini, R. Bellazzini, A. Brez, L. de Ruvo, M. Minuti, M. Pinchera, C. Sgrò, G. Spandre, D. Spiga, G. Tagliaferri, G. Pareschi, S. Basso, O. Citterio, V. Burwitz, W. Burkert, B. Menz, G. Hartner

    Abstract: X-rays are particularly suited to probe the physics of extreme objects. However, despite the enormous improvements of X-ray Astronomy in imaging, spectroscopy and timing, polarimetry remains largely unexplored. We propose the photoelectric polarimeter Gas Pixel Detector (GPD) as an instrument candidate to fill the gap of more than thirty years of lack of measurements. The GPD, in the focus of a te… ▽ More

    Submitted 27 March, 2014; originally announced March 2014.

    Comments: Accepted for publication in The Astrophysical Journal Supplement

  3. arXiv:1402.3445  [pdf

    astro-ph.IM astro-ph.HE physics.ins-det

    Evaluation of the surface strength of glass plates shaped by hot slum** process

    Authors: L. Proserpio, S. Basso, F. Borsa, O. Citterio, M. Civitani, M. Ghigo, G. Pareschi, B. Salmaso, G. Sironi, D. Spiga, G. Tagliaferri, A. D'Este, R. Dall'Igna, M. Silvestri, G. Parodi, F. Martelli, M. Bavdaz, E. Wille

    Abstract: The Hot Slum** Technology is under development by several research groups in the world for the realization of grazing-incidence segmented mirrors for X-ray astronomy, based on thin glass plates shaped over a mould at temperatures above the transformation point. The performed thermal cycle and related operations might have effects on the strength characteristics of the glass, with consequences on… ▽ More

    Submitted 9 July, 2014; v1 submitted 14 February, 2014; originally announced February 2014.

    Comments: Accepted for publication in Optical Enginnering (Jun 26, 2014)

  4. Re-testing the JET-X Flight Module No. 2 at the PANTER facility

    Authors: Daniele Spiga, Gianpiero Tagliaferri, Paolo Soffitta, Oberto Citterio, Stefano Basso, Ronaldo Bellazzini, Alessandro Brez, Wolfgang Burkert, Vadim Burwitz, Enrico Costa, Luca de Ruvo, Ettore Del Monte, Sergio Fabiani, Gisela Hartner, Benedikt Menz, Massimo Minuti, Fabio Muleri, Giovanni Pareschi, Michele Pinchera, Alda Rubini, Carmelo Sgrò, Gloria Spandre

    Abstract: The Joint European X-ray Telescope (JET-X) was the core instrument of the Russian Spectrum-X-gamma space observatory. It consisted of two identical soft X-ray (0.3 - 10 keV) telescopes with focusing optical modules having a measured angular resolution of nearly 15 arcsec. Soon after the payload completion, the mission was cancelled and the two optical flight modules (FM) were brought to the Brera… ▽ More

    Submitted 18 February, 2014; v1 submitted 9 November, 2013; originally announced November 2013.

    Comments: Author's accepted manuscript posted to arXiv.org as permitted by Springer's Self-Archiving Policy. The final publication is available at http://rd.springer.com/article/10.1007%2Fs10686-013-9365-y

    Journal ref: Experimental Astronomy, February 2014, Vol. 37(1), p. 37-53

  5. arXiv:1105.0637  [pdf, ps, other

    astro-ph.IM astro-ph.HE

    POLARIX: a pathfinder mission of X-ray polarimetry

    Authors: Enrico Costa, Ronaldo Bellazzini, Gianpiero Tagliaferri, Giorgio Matt, Andrea Argan, Primo Attina', Luca Baldini, Stefano Basso, Alessandro Brez, Oberto Citterio, Sergio Di Cosimo, Vincenzo Cotroneo, Sergio Fabiani, Marco Feroci, Antonella Ferri, Luca Latronico, Francesco Lazzarotto, Massimo Minuti, Ennio Morelli, Fabio Muleri, Lucio Nicolini, Giovanni Pareschi, Giuseppe Di Persio, Michele Pinchera, Massimiliano Razzano , et al. (8 additional authors not shown)

    Abstract: Since the birth of X-ray astronomy, spectral, spatial and timing observation improved dramatically, procuring a wealth of information on the majority of the classes of the celestial sources. Polarimetry, instead, remained basically unprobed. X-ray polarimetry promises to provide additional information procuring two new observable quantities, the degree and the angle of polarization. POLARIX is a m… ▽ More

    Submitted 3 May, 2011; originally announced May 2011.

    Comments: 42 pages, 28 figures

    Journal ref: Exper.Astron.28:137-183,2010

  6. arXiv:0912.5331  [pdf, ps, other

    astro-ph.IM astro-ph.HE

    A wide field X-ray telescope for astronomical survey purposes: from theory to practice

    Authors: P. Conconi, S. Campana, G. Tagliaferri, G. Pareschi, O. Citterio, V. Cotroneo, L. Proserpio, M. Civitani

    Abstract: X-ray mirrors are usually built in the Wolter I (paraboloid-hyperboloid) configuration. This design exhibits no spherical aberration on-axis but suffers from field curvature, coma and astigmatism, therefore the angular resolution degrades rapidly with increasing off-axis angles. Different mirror designs exist in which the primary and secondary mirror profiles are expanded as a power series in or… ▽ More

    Submitted 11 February, 2010; v1 submitted 29 December, 2009; originally announced December 2009.

    Comments: Accepted for publication in the MNRAS (11pages, 3 table, 13 figures)

  7. arXiv:0903.2483  [pdf, ps, other

    astro-ph.IM

    Simbol-X Hard X-ray Focusing Mirrors: Results Obtained During the Phase A Study

    Authors: G. Tagliaferri, S. Basso, G. Borghi, W. Burkert, O. Citterio, M. Civitani, P. Conconi, V. Cotroneo, M. Freyberg, D. Garoli, P. Gorenstein, G. Hartner, V. Mattarello, A. Orlandi, G. Pareschi, S. Romaine, D. Spiga, G. Valsecchi, D. Vernani

    Abstract: Simbol-X will push grazing incidence imaging up to 80 keV, providing a strong improvement both in sensitivity and angular resolution compared to all instruments that have operated so far above 10 keV. The superb hard X-ray imaging capability will be guaranteed by a mirror module of 100 electroformed Nickel shells with a multilayer reflecting coating. Here we will describe the technogical develop… ▽ More

    Submitted 13 March, 2009; originally announced March 2009.

    Comments: 6 pages, 3 figures, invited talk at the conference "2nd International Simbol-X Symposium", Paris, 2-5 december, 2008

    Journal ref: AIP Conf.Proc.1126:35-40,2009

  8. An X-ray Polarimeter for HXMT Mission

    Authors: Enrico Costa, Ronaldo Bellazzini, Gianpiero Tagliaferri, Luca Baldini, Stefano Basso, Johan Bregeon, Alessandro Brez, Oberto Citterio, Vincenzo Cotroneo, Filippo Frontera, Massimo Frutti, Giorgio Matt, Massimo Minuti, Fabio Muleri, Giovanni Pareschi, Giuseppe Cesare Perola, Alda Rubini, Carmelo Sgro', Paolo Soffitta, Gloria Spandre

    Abstract: The development of micropixel gas detectors, capable to image tracks produced in a gas by photoelectrons, makes possible to perform polarimetry of X-ray celestial sources in the focus of grazing incidence X-ray telescopes. HXMT is a mission by the Chinese Space Agency aimed to survey the Hard X-ray Sky with Phoswich detectors, by exploitation of the direct demodulation technique. Since a fractio… ▽ More

    Submitted 25 September, 2007; originally announced September 2007.

    Comments: 10 pages, 9 figures

    Journal ref: Proceedings of SPIE Optics + Photonics 2007 Conference - San Diego, vol. 6686-32

  9. arXiv:0709.1372  [pdf, ps, other

    astro-ph

    The reflecting surface of the MAGIC-II Telescope

    Authors: D. Bastieri, J. Arnold, C. Baixeras, O. Citterio, F. Dazzi, B. De Lotto, M. Doro, M. Ghigo, E. Giro, F. Goebel, R. Kosyra, E. Lorenz, M. Mariotti, R. Mirzoyan, R. Paoletti, G. Pareschi, D. Pascoli, A. Pepato, L. Peruzzo, A. Saggion, P. Sartori, A. Sillanpää

    Abstract: The MAGIC Collaboration is building a second telescope, MAGIC II, improving the design of the current MAGIC Telescope. MAGIC II is being built at 85 m of distance from MAGIC I, and will also feature a huge reflecting surface of ~240 m$^2$ of area. One of the improvement is the design for the mirror of MAGIC II, that are lighter and larger, being square of 1 m of side and weighting around 15 kg.… ▽ More

    Submitted 10 September, 2007; originally announced September 2007.

    Comments: Contribution to the 30th ICRC, Merida Mexico, July 2007 on behalf of the MAGIC Collaboration

  10. The in-flight spectroscopic performance of the Swift XRT CCD camera during 2006-2007

    Authors: O. Godet, A. P. Beardmore, A. F. Abbey, J. P. Osborne, K. L. Page, L. Tyler, D. N. Burrows, P. Evans, R. Starling, A. A. Wells, L. Angelini, S. Campana, G. Chincarini, O. Citterio, G. Cusumano, P. Giommi, J. E. Hill, J. Kennea, V. LaParola, V. Mangano, T. Mineo, A. Moretti, J. A. Nousek, C. Pagani, M. Perri , et al. (4 additional authors not shown)

    Abstract: The Swift X-ray Telescope focal plane camera is a front-illuminated MOS CCD, providing a spectral response kernel of 135 eV FWHM at 5.9 keV as measured before launch. We describe the CCD calibration program based on celestial and on-board calibration sources, relevant in-flight experiences, and developments in the CCD response model. We illustrate how the revised response model describes the cal… ▽ More

    Submitted 22 August, 2007; originally announced August 2007.

    Comments: 8 pages, 5 colour figures, submitted to SPIE

  11. POLARIX: a small mission of x-ray polarimetry

    Authors: Enrico Costa, Ronaldo Bellazzini, Paolo Soffitta, Fabio Muleri, Marco Feroci, Massimo Frutti, Marcello Mastropietro, Luigi Pacciani, Alda Rubini, Ennio Morelli, Luca Baldini, Francesco Bitti, Alessandro Brez, Francesco Cavalca, Luca Latronico, Marco Maria Massai, Nicola Omodei, Michele Pinchera, Carmelo Sgro', Gloria Spandre, Giorgio Matt, Giuseppe Cesare Perola, Guido Chincarini, Oberto Citterio, Gianpiero Tagliaferri , et al. (2 additional authors not shown)

    Abstract: X-Ray Polarimetry can be now performed by using a Micro Pattern Gas Chamber in the focus of a telescope. It requires large area optics for most important scientific targets. But since the technique is additive a dedicated mission with a cluster of small telescopes can perform many important measurements and bridge the 40 year gap between OSO-8 data and future big telescopes such as XEUS. POLARIX… ▽ More

    Submitted 20 September, 2006; originally announced September 2006.

    Comments: 9 pages, 5 figures

    Journal ref: SPIE proceedings, Vol. 6266 0R-1, 24-31 May 2006, Orlando (Florida), M.J. Turner, G. Hasinger eds

  12. An X-ray polarimeter for hard X-ray optics

    Authors: Fabio Muleri, Ronaldo Bellazzini, Enrico Costa, Paolo Soffitta, Francesco Lazzarotto, Marco Feroci, Luigi Pacciani, Alda Rubini, Ennio Morelli, Luca Baldini, Francesco Bitti, Alessandro Brez, Francesco Cavalca, Luca Latronico, Marco Maria Massai, Nicola Omodei, Michele Pinchera, Carmelo Sgro', Gloria Spandre, Giorgio Matt, Giuseppe Cesare Perola, Oberto Citterio, Giovanni Pareschi, Vincenzo Cotroneo, Daniele Spiga , et al. (1 additional authors not shown)

    Abstract: Development of multi-layer optics makes feasible the use of X-ray telescope at energy up to 60-80 keV: in this paper we discuss the extension of photoelectric polarimeter based on Micro Pattern Gas Chamber to high energy X-rays. We calculated the sensitivity with Neon and Argon based mixtures at high pressure with thick absorption gap: placing the MPGC at focus of a next generation multi-layer o… ▽ More

    Submitted 20 September, 2006; originally announced September 2006.

    Comments: 12 pages, 7 figures

    Journal ref: SPIE proceedings, Vol. 6266 2X-1, 24-31 May 2006, Orlando (Florida), M.J. Turner, G. Hasinger eds

  13. The in-flight spectroscopic performance of the Swift XRT CCD camera

    Authors: J. P. Osborne, A. P. Beardmore, O. Godet, A. F. Abbey, M. R. Goad, K. L. Page, A. A. Wells, L Angelini, D. N. Burrows, S. Campana, G. Chincarini, O. Citterio, G. Cusumano, P. Giommi, J. E. Hill, J. Kennea, V. La Parola, V. Mangano, T. Mineo, A. Moretti, J. A. Nousek, C. Pagani, M. Perri, P. Romano, G. Tagliaferri , et al. (1 additional authors not shown)

    Abstract: The Swift X-ray Telescope (XRT) focal plane camera is a front-illuminated MOS CCD, providing a spectral response kernel of 144 eV FWHM at 6.5 keV. We describe the CCD calibration program based on celestial and on-board calibration sources, relevant in-flight experiences, and developments in the CCD response model. We illustrate how the revised response model describes the calibration sources wel… ▽ More

    Submitted 17 October, 2005; originally announced October 2005.

    Comments: 8 pages, including 7 figures. Submitted to proceedings of SPIE 5898, UV, X-Ray and Gamma-Ray Space Instrumentation for Astronomy XIV

    Journal ref: AIP Conf.Proc.836:708-711,2006

  14. SIMBOL-X, a formation flying-mission for hard X-ray astrophysics

    Authors: P. Ferrando, A. Goldwurm, P. Laurent, O. Limousin, J. Martignac, F. Pinsard, Y. Rio, J. P. Roques, O. Citterio, G. Pareschi, G. Tagliaferri, F. Fiore, G. Malaguti, U. Briel, G. Hasinger, L. Strueder

    Abstract: SIMBOL-X is a hard X-ray mission, operating in the ~ 0.5-70 keV range, which is proposed by a consortium of European laboratories in response to the 2004 call for ideas of CNES for a scientific mission to be flown on a formation flying demonstrator. Relying on two spacecrafts in a formation flying configuration, SIMBOL-X uses for the first time a ~ 30 m focal length X-ray mirror to focus X-rays… ▽ More

    Submitted 31 August, 2005; originally announced August 2005.

    Comments: 10 pages; Proc. of SPIE conference "Optics for EUV, X-Ray, and Gamma-Ray Astronomy II", San Diego July 31st-Aug.4th, 2005, Vol. 5900

  15. The Swift X-ray Telescope

    Authors: David N. Burrows, J. E. Hill, J. A. Nousek, J. A. Kennea, A. Wells, J. P. Osborne, A. F. Abbey, A. Beardmore, K Mukerjee, A. D. T. Short, G. Chincarini, S. Campana, O. Citterio, A. Moretti, C. Pagani, G. Tagliaferri, P. Giommi, M. Capalbi, F. Tamburelli, L. Angelini, G. Cusumano, H. W. Braeuninger, W. Burkert, G. D. Hartner

    Abstract: The Swift Gamma-Ray Explorer is designed to make prompt multiwavelength observations of Gamma-Ray Bursts (GRBs) and GRB afterglows. The X-ray Telescope (XRT) enables Swift to determine GRB positions with a few arcseconds accuracy within 100 seconds of the burst onset. The XRT utilizes a mirror set built for JET-X and an XMM/EPIC MOS CCD detector to provide a sensitive broad-band (0.2-10 keV) X… ▽ More

    Submitted 2 August, 2005; originally announced August 2005.

    Comments: 36 pages, 24 figures

    Journal ref: SpaceSci.Rev.120:165,2005

  16. arXiv:astro-ph/0507013  [pdf, ps, other

    astro-ph

    An X-ray Galaxy Cluster Survey for Investigations of Dark Energy

    Authors: Z. Haiman, S. Allen, N. Bahcall, M. Bautz, H. Boehringer, S. Borgani, G. Bryan, B. Cabrera, C. Canizares, O. Citterio, A. Evrard, A. Finoguenov, R. Griffiths, G. Hasinger, P. Henry, K. Jahoda, G. Jernigan, S. Kahn, D. Lamb, S. Majumdar, J. Mohr, S. Molendi, R. Mushotzky, G. Pareschi, J. Peterson , et al. (12 additional authors not shown)

    Abstract: The amount and nature of dark energy (DE) can be tightly constrained by measuring the spatial correlation features and evolution of a sample of ~ 100,000 galaxy clusters over the redshift range 0<z < 1.5. Such an X-ray survey will discover all collapsed structures with mass above 3.5e14 solar masss at redshifts z<2 (i.e. the full range where such objects are expected) in the high Galactic latitu… ▽ More

    Submitted 30 June, 2005; originally announced July 2005.

    Comments: White paper submitted to the Dark Energy Task Force, 7 pages plus 5 figures and appendix

  17. HEXIT-SAT: a mission concept for X-ray grazing incidence telescopes from 0.5 to 70 keV

    Authors: F. Fiore, G. C. Perola, G. Pareschi, O. Citterio, A. Anselmi, A. Comastri

    Abstract: While the energy density of the Cosmic X-ray Background (CXB) provides a statistical estimate of the super massive black hole (SMBH) growth and mass density in the Universe, the lack, so far, of focusing instrument in the 20-60 keV (where the CXB energy density peaks), frustrates our effort to obtain a comprehensive picture of the SMBH evolutionary properties. HEXIT-SAT (High Energy X-ray Imagin… ▽ More

    Submitted 30 July, 2004; originally announced July 2004.

    Comments: to appear in Proceeedings of SPIE Vol. 5488, UV to Gamma Ray Space Telescope Systems

  18. SIMBOL-X : a new generation hard X-ray telescope

    Authors: P. Ferrando, M. Arnaud, B. Cordier, A. Goldwurm, O. Limousin, J. Paul, J. L. Sauvageot, P. O. Petrucci, M. Mouchet, G. Bignami, O. Citterio, S. Campana, G. Pareschi, G. Tagliaferri, U. Briel, G. Hasinger, L. Strueder, P. Lechner, E. Kendziorra, M. Turner

    Abstract: SIMBOL-X is a hard X-ray mission, operating in the 0.5-70 keV range, which is proposed by a consortium of European laboratories for a launch around 2010. Relying on two spacecraft in a formation flying configuration, SIMBOL-X uses a 30 m focal length X-ray mirror to achieve an unprecedented angular resolution (30 arcsec HEW) and sensitivity (100 times better than INTEGRAL below 50 keV) in the ha… ▽ More

    Submitted 16 September, 2003; originally announced September 2003.

    Comments: 12 pages, 16 fig., Proc. SPIE conf. 5168, San Diego, Aug. 2003

  19. arXiv:astro-ph/9711027  [pdf, ps, other

    astro-ph

    Final performances of the X-ray Mirrors of the JET-X telescope

    Authors: E. Poretti, S. Campana, O. Citterio, P. Conconi, M. Ghigo, F. Mazzoleni, G. Tagliaferri, G. Cusumano, G. La Rosa, W. Brauninger, W. Burkert, C. M. Castelli, R. Willingale

    Abstract: The Joint European Telesscope (JET-X) is one of the core scientific instruments of the SPECTRUM-X-Gamma mission. JET-X was designed to study X-ray emissions in the band 0.3-10 KeV. Its angular resolution is better than 20 arcsec; the values of the effective areas are 161 cm2 at 1.5 KeV and 69 cm2 at 8 Kev (for one telescope). The value of the HEW circle in function of the off-axis angle is prese… ▽ More

    Submitted 4 November, 1997; originally announced November 1997.

    Comments: 2 pages, 1 ps figure. To be published in the Proceedings of the IAU Symposium 188 THE HOT UNIVERSE, held in Kyoto (August 26-30, 1997) in occasion of the XXIII IAU General Assembly